Loading...
HomeMy WebLinkAbout14070086 Energy Certificate i HOII�E CERTIFIED �O NlEET TFIE PFiOVISIONS OF THE 2009 IIVTERIVATIOtVA�L ENERGY CONSERVATION CODE This home built at 3891 PELFiAIVI R�., CARIVIEL (AS DESIGNED), IN by FISCHER HOMES exceeds the minimum requirements for the 2009 International Energy Conservation Code 07-10-2014 Building Features . Ceiling Flat: R-38.0 Duct Leakage to Outside: 363.00 CFM @ 25 Pascals Sea�ed Attic: NA Total Duct Leakage: 644.00 CFM @ 25 Pascals . VaWted Ceiling: NA Infiltration: Htg:6.00 CIg:6.00 ACH50 Above Grade Walls: R-15.0 Window; U-Value:0.310,SHGC:0280 Foundation Walis: R-11.0 Heating Fuel-tired airdistribution,Naturalgas,95.0!EFF. Exposed Floor: R-30.5 Cooling Air conditioner,Electric, 13.0 SEER. Slab: R-10.0 Edge, R-10.0 Under Water Heating Conventional, Electric,0.88 EF,66A�Gal. I �Quct: NA The organization below certities that ihe proposed building design tlescribed herein is consistent with the building plans,specifications,and other � calculations submitted with the permit application.The proposed building has been designed to meet the 2009 IECC�equirements in corripliance with � Chapter 4 based on Climate Zone 5A and with all mandaiory requirements. Name: DEVIN SIELSCHOTT SignaNre:� Organization: THERMO SCAN INSPECTIONS Date: July 10.2014 7Ae 20091nternationai Energy Conservation Code is a registeretl trademark o/the Infemafional Code Council,Ina('7CC"J. No version o/this sottware has been:reviewed or approved by ICC or its af/iliates. REM/Rate-Residential Ener Anal sis and Ratin Soltware v14.5