HomeMy WebLinkAbout14070082 Energy Certificate � -�- ..
w. _
HOME CERTIFIED TO IVIEET THE PROVISIONS OF THE
2009 IIVTERN�4TIOIVAL ENERGY CONSERVATION CODE
This home built at
14279 OVERBROOK DR., CARMEL (AS DESIGNED), IN
by FISCHER HOMES
exceeds the minimum requirements for the 2009 International Energy Conservation Code
06-30-2014
Bullding Features
Ceiling Flat R-38 Duct Leakage ro Outside: 403.00 CFM @ 25 Pascals
Sealed Attic: NA Total Duct Leakage: 552.00 CFM @ 25 Pascals
VaufledCeiling: NA Infiltration: Htg:6.00CIg:6.00ACH50
AboveGradeWalls: R-15 Window: U-Value:0.310,SHGC:0280
Foundation Walls: R-11.5, R-13.0 Heating Fuel-fired air disiribution,Natural gas,95.0%EFF.
Exposed Floor: R-30 Cooling Air conditioner,Electric,13.0 SEER.
Slab: R-0.0 Edge,R-0.0 Under Water'Heating Conventional,Natural gas,0.65 EF,50.0 Gal.
Duct: NA
The organization�below certifies that the proposed bullding.design described herein is consistent with the.building plans,specitications,and other
calculatlons submitted with the permit appllcation.The proposed building has�been designed to meet the 20D9 IECC,requirements In complfance with
Chapter 4 based on Climate Zone SA and with all mandatory requlrements.
Name: DEVIN SIELSCHOTT Signature:
Organization: THERMO SCAN INSPECTIONS Date: June 30,2074
The 2009Internatlonal Energy Conservallon Code!s a registered trademark o/fhe Intemaflonal Code Council,Inc.("lCC").
No version o/this so/tware has been revlewed�orapproved 6y ICC or Its alliliates.
REM/Rate-Resldenfial Ene Anal s!s and Ratln So/tware v14.3