Loading...
HomeMy WebLinkAbout14070058 Energy Certificate HONIE CERTIFIED TO iVIEET THE PROVISIONS OF THE 2009 IRlTERN�►TIOi�AL EfVERGY CONSERVATION CODE This home built at 6750 �rauer Cour� Carmel, IN 46033 by NVR, Inc. exceeds the minimum requirements for the 2009 International Energy Conservation Code �-8-i a � Building Features Ceiling Flat: R-38 Duct Leakage to Outside: -<4 CFM25per 100 sq. ft. VaWted Ceiling: R38 Total Duct Leakage: <-8 CFM25 per 100 sq. ft. Above G�ade Walls: R-15+ R3 CoM. Infiltration: s 4 ACH50 Foundation Walls: R-11 Window: U-Value= 0.3,SHGC= 02 Exposed Floor. R38 Heating: Fuel-fired air distribution, Natural Gas, 95 AFUE Slab: N/A Cooling: Air conditioner, Electric, 13 SEER Duct: R�-8 Water Heating: Conventional, Natural Gas,0.66 EF, 65 Gal The orpanization below certifies that the proposed buildinp desipn described herein is consistenbwith tfie buildinq plans, specifications, and other calculation submitted with the permit application. The proposed building has been designed to,meet the2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Name: ScoH Atkinson Signature: �� � Organization� PEG(Resnet Rater-Provider) Date: 7-8-14 The 2009 International Ener9Y Conservation Code�is a registered trademark oPthe Intemational Code Council, Ina ("ICC"). No ve�sion.of this software has'tieeh Peviewed orapproved dy..ICG orits affiliates. REM/Rate-Residential Energy Analysis and Ratinp Software v12.99