Loading...
HomeMy WebLinkAboutDec 13 2001 03 Site Development PlanW J _J 2 U IL 0 it N IR N 0 00 N 0 a J 3 v O 0 CD v W) 0 cc 0 v 0 D_ LL BENCHMARKS: T.B.M. #1 (S &A) — NAIL SET @ S. SIDE, TEL. POLE ON THE S. SIDE OF 131ST. APPROX. 70'± W OF W PROPERTY LINE 1.5' UP FROM GROUND. ELEV.= 916.10 T.B.M. #2 (S &A) — NAIL SET ® W. SIDE OF PWR POLE ON THE S. SIDE OF 131ST APPROX. 130'± E. OF E. PROPERTY LINE 1.5' UP FROM GROUND. POLE #55 -125 ELEV.= 906.04 S &A CP (M4) — REBAR SET ® S. SIDE OF 131ST APPROX. 300'± E. OF W. PROPERTY LINE. ELEV.= 911.65 EXISTING GRADE ,1 NORMAL POOL 1r ROPOSED GRADE is-ON .. 1 — J. 10' z 10' MIN. 3 3 MIN. 11 M 1r TYPICAL LAKE CROSS— SECTION N.T.S. NOTE: SIDEWALK ADJACENT TO COMMON AREA TO BE INSTALLED BY CONTRACTOR. RECEIVE 13 C� DocS SCALE: 1 "= 50' LEGEND EXISTING CONTOUR EXISTING SANITARY SEWER —0— — EXISTING STORM SEWER ® PROPOSED GRADE e+�-- PROPOSED CONTOUR PROPOSED SANITARY SEWER —t — PROPOSED STORM SEWER PROPOSED SWALE PROPOSED 4' SIDEWALK (BY HOME BUILDER) LOT NUMBER 905.7 PAD ELEVATION PAD SIZE 50'x55' HOUSE TO BE EXTENDED BACK TO 75' ® I SPECIAL DRAINAGE (FROM REAR OF LOT I TO FRONT AROUND HOUSE.) ti CT No. Z 19358 S/T�A►yT�E�jO�F f �� DENOTES 4" SUBSURFACE DRAIN TO LOT �– DENOTES 6" SUBSURFACE DRAIN ROLL CURB NOTE: DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES, LANDSCAPING MOUNDS, LIGHT POLES, OR OTHER SUCH AMENITIES ARE NOT PERMITTED IN THE RIGHT OF WAY. ALL PADS SHOULD BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95% OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. EARTHWORK: 1. EXCAVATION A. Excavated material that is suitable may be used for fills. All unsuitable material and all surplus excavated material not required shall be removed from the site. B. Provide and place any additional fill material from offsite as may be necessary to produce the grades required on plans. Fill obtained from offsite shall be of quality as specified for fills herein and the source approved by the Developer. It will be the responsibility of the Contractor for any costs for fill needed. 2. REMOVAL OF TREES A. All trees and stumps from area to be occupied by a road surface area and building pad. Trees and stumps shall not be buried on site. 3. PROTECTION OF TREES A. The Contractor shall, at the direction of the Developer, endeavor to save and protect trees of value and worth which do not impair construction of improvements as designed. B. In the event cut or fill exceeds 0.5 foot over the root area, the Developer shall be consulted with respect of protective measure to be taken, if any, to preserve such trees. 4. REMOVAL OF TOPSOIL A. All topsoil shall be removed from all areas to be excavated. Topsoil should be stored at a location where it will not interfere with construction operations. The topsoil shall be free of debris and stones. 5. UTILITIES A. Rules and regulation governing the respective utility shall be observed in executing all work under this section. B. It shall be the responsibility of the Contractor to determine the location of existing underground utilities 2 working days prior to commencing work. For utility locations to be marked call Toll Free 1- 800 - 382 -5544 within Indiana or 1 -800- 428 -5200 outside Indiana. 6. SITE GRADING A. Do all cutting, filling, compacting of fills and rough grading required to bring entire project area to subgrade as shown on the drawing. B. The tolerance for paved areas shall not exceed 0.10 feet above established subgrade. All other areas shall not exceed 0.10 feet plus or minus the established grade. Provide roundings at top and bottom of banks and other breaks in grade. C. The Engineer shall be notiied when the Contractor has reached the tolerance as stated above, so that field measurements and spot elevations can be verified by the Engineer. The Contractor shall not remove his equipment from the site until the Engineer has verified that the job meets the above tolerance. FORM \EARTHWRK "HOLEY MOLEY" SAYS: — 800 - 382 -5544 CALL TOLL FREE 1-800-428-5200 FOR CALLS OUTSIDE OF INDIANA CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. } m 0] cn in a a W X Y Q p WSW T_ r- 0 W o! W U i) ry N rn 0 L0 CK Z 0 M � X Z Q Q J I rn v, � I 00 W r- W I Z 0 0 00 Z I U.J C� `n M Z LO 'J rn V) 00 Z 0 Q a 0 z N J 0 CL Q Q 0 z SHEET NO. 3 OF 21 sHEm " NO-40605 Z Q 0 Z 1 11 1 O U Z W W L o Z J Z) W Of W Z C) W W �- F— Q V) SHEET NO. 3 OF 21 sHEm " NO-40605 Z Q 0 Z 1 11 1