Finished Floor Eleva[lon(FfE)Inlormation
PadGrade = 755.5 perplan
Pad Gratle + 1.0' = Garage FFE(75fi.5f LOT # 35 Plot Plan Lepand
Garage FFE f 1.9' =Residence FFE(758.4) � Propo¢ed (#�adea
ResidenceFFE- 8.9'=BasementFFE�749.5� OOO.D ExlstfnqLYadea
M.F.F.=756.8 �000.0� Coniour Grade
M.F.P.G.=7561(FRONT) �k . Appra�. Lateral lacatfon
— s � Sanftnry Sawer lJnas
M.L.A.G.=756.1�FRONT) � —�1–� Siartn Serer lJnas
M.f.P.G.=756.4(REAIi) — v — Water Sarvica linp
M.LA.G.=756A�REAR) – – – –– – – �6–Surtoce Dmh Lfnea
m Uanhde (Sanitary or Storm)
GroundCaverAreaCalculations � Beehiw Inlet.(Stam)
Orive =787 SFt/- � �Ulb ���e{ �$tOrtn�
PublicWalk = 2105P+/� PrivateWalk= 32 SF+/� � D End SeydCtlan (Stornl)
Hydwseeding =4,845 SFr/- Q —._ _�� ._ —Fbe Lln of ewale
SoJ = 1C25Y+/- (framfrontofresidencel l�sumed Naih — — BuIlding Lloe (BL � BSL)
Scale : 1" � 3�' – – ––– – – Eaeanant Lina
Optlonal sod package
Hydroseeding = 1,OSfi SF+/- p /�/�/�
Addi[IonalSod Package = 421 SY+/-to reareasemenl r�� � ��-10-23-00-06-003.WV
Sidewolk to he placed
on the praperty line,
5' from back of curb, s�t I eos
per plan. P����o LOT � 34
auwNC NO RESI�QJCE
� J
�
. I I I . : �
.
M 7,1' . �
30.0'I � I� �a7s 51.6'
� B� � g ° �� � � � ��� � g I° l :
I o � I � � d ��� � _ � �
0 0 � � ,� � � �� � � — �^
� �, � .�
� N � � � �� � � � I
I Y � ' � � � 1
�
�� �' 7.7 � 135.44� � � I
M ��I 7 g ----►
.
i PR PIAN I � I 3 0 I I
�
4�� OP � SL�E LDT 36
4'
NO R SIDENCE
TYPICAL SWALE SEC710N
NOIE IN 7HE RE90FNilAL qSf10Cf5 11MI71NG �
HOq11 TO 7HENTY–FlVE (25) FFET, A DXEWNG
MAY 9E INqtEASID IN H�Qi7 TU�7HIR7Y-FlVE (�3)
FFET PRONDm 1HE SIDE�AND REAR YAADS Af�f
SNNANRE:
INCREASED AN ADUITIONAL FW�FOR�EACH FUOT �A�
SH)I SIRUCTIINE•E%(�S�7NEN7Y–FIVE(73).fEEf
M'HFIGHL:PEft CARWEI ZONINC ORDINANC�'18.1.L
9p1AlUE P�75 CQFIRNAlION ff�'f Oi PIDT PIAN BY WSIOMFA.
� Garage Finlsh Floor Elevation-The garage finish Floor elevation Is 1.2 feet a6o�e Ihe curb at the drive per plan,
� Nearby Manhole Casling Elevations�The upstream sanitary manhole has a top oFcasting elevation of 756.30 per plan and the downstream sanitary manhole has a top of
castfng elevatlon of 756.54 per remrd drawing. The upstream sanllary manhole top of casUng elevatlon shall be no less than one Foot�]'-0"�below the EF.E,of the
residence. '
SHEET 1 OF 2
PLOT PLAN SCALE: 1"=30' Job # 14.0109903
Preparetl For: R.H.OF INDIANA
Subtlivision: THE MEADOWS AT THE LECACY SECTION 2 ' LOT 35 �
Recortling Info: 2014014219 and C.O:C. 2 0 140 189 7 9 LotSize: 9,077 SP
County: HAMILTON Township: CLAY Sec/Twp/Rng: SEC 22-TIBN-R4E
Street Address 14067 KNIGHTSTOWN.DRIVE EAST,CARMEL IN 46033 ' R/W:50'
Buyer/Owner: R�GHU 6.IMMADISET,TY.
Preparetl By: JAW DATE b7-11-14 ,/t
V`�
1 .
The Schneider Corporation
�n•��� HlstorlcFortHerrlson 89010tlsAvenue indlanapolls,INA6216d037 Phone:317.826.7100 Fax: 317�8267200
�
SHEET 2 of 1(NOTE•this Plot Plan Is not complete unless 6oth sheets are present)
CommunRy Restrlctions•Zoning and Setbacks
SldeYard=3feet RearYard=20feet
Agg.=SfeetBH Zoning=PUD
The client antl mntractor's attention are directed to the following notes:
• Purpose-The within plot plan was prepared only for the benefi[of the parties Indicated hereon and for[he express purpose of obtaining a residential
construction permit only.
• Information from others-This plot plan was mmpiled based impart on documents,such as construction plans or record drawings,prepared by others,and
is not based on a field survey. The Schneider Corp�rakion cannot and does not warrant the accuracy,completeness,acwptance or sufficiency of such
information,
� Lowest Finished Floor Elevation-1he lowest floor elevation depicted hereon haSbeen determined based on a variety of factors induding,but not limited
to,�i)the pad grades,elevations and�or contours taken from the construction plans for this subdivision,(ii)the architectural plans for the dwelling,and(iiil
nearby bodies of water and jurlsdictlonal flood prctection gratles,if any. Unless otherwise stated,no information about watertables,soil wnditions,or
soil types has been provided or stated ornsaid plans.If any ground warer Is encountered during the excavation,or if other known water elevation or soils
conditions are present,the builder shoultl contactThe Schneider Corporation to discuss possible courses of action,
• It islhe undersigned's opinion[ha[Iithe pYoposed finished grades are constructed as shown,Ihe surfaw drainage on the subject lotwill be satisfactory for residential
construcdon,
• Minimal Tolerances-If the home location shown hereon has minimal tolerance for placement of sald hame due to its proximity to setback lines and/or
easement lines, it is suggested that the builder have the foundation pinned after the footing is poured to help ensure that the improvements do not
encroach upon such lines.
• Existing Conditions-Contra�tors should verify existing conditions prior toany construction. Any discrepancy found on this drawing should be immediately
reported to The Schneicier Corporation. Failure to�io so will residt in tlie contrador's assumption of allJiability.
� Drainage-Contractor to ensure positive drainage away from struaure(s).
• SeWer/WaterLineSeparation-Contractortomaintainaminimumdlstanceoftenfeet(10'-0"� betweenwaterlineandsanitarysewerlaterals.
� Sanitary Lateral-Contractor shall cut excess off of sanitary lateral as necessary and begin from that point and connect to house.
. Sump Pumps-Contractor to place sump pump�s)as needed.
� Pavement and Manholes/Cleanouts-Contractor shall not place pavement or concrete,inclutling tlrivewaysantl sidewalks,on or wiChln one foot(l'-0"�
horizontallyof any sanitary sewer manhole ar c�ean out casting.
. Sidewalk Placement-It is the responsibiliry of the contractor to ensure rorrect sitlewalk placemenk See sidewalk details and/or as built plans as available
forspecific sidewalk details and placement.
• Ramps-Cqntractor to install street access ramps in acmrdance with munlcipality�equirements,
• Note•This drawing is not intended to be represented as a retracement or original boundary survey,a route survey,or a surveyor location repart.
Flaod Hazard Statement
The aauracy of any Hood haiard da[a shown on this plot plan�ls subje�t to map scale uncertainty and to any otfier uncertainty in location�or elevatlon on the rnferenced(lard
insu2nce rate map(FlRM�. ALL of tBe within described land DOES NOT LIE within thatSpecial Flood Haiartl Area Zone'�X°,as sald land plots by scale on Community Map Nanel
18057C 0235F of Ihe flood insurance ra[e map(FIRM�for Hamilton County,Indlana,dated fehruary 19,2003.
\\\\\\\0\Q\�\Spllllilllllllq�//�/////////
\Q���.���s T'e'R��,�i��
� �- No, °� ,o,
' S0303 �:
� '� ° STATE OF ' �
' �%l,��0�N D I A�'!,P,��Q�\��
, ���"4�iprra�i uimRm���`"°�\\•
�.L.
SHEET 2 OF 2
PLOT PLAN SCALE: 1"=30' Jo� # 14.0109903
PreparetlFOr: R.H.OF INDIANA
Subdivision: THE MEADOWS AT THE LECACY SECTION 2 LOT 35
RecortlingJnfo: 2014014218 antl C.O.C. 2 0 14 0189 7 9 LocSize: 9,077 SF
County HAMILTON Township: CLAY Sec/Twp/Rng: SEC 22-T1BN-R4E
Street AtltlrPSS: 14067 KNIGHTSTOWN DRIVE EAST, CARMEL IN 4G033 R/W:50'
8uyef/OwneY: RAGHU B.IMMADISETTY �
Prepared 8y: JAW OATE: 07-11-14
The Schneider Corporation
����^ Hlstorlc�FortNa�dson 89010tIsAvenue Indlanapolls,IN46216-1037 Phona:317.826.7100 Pax: 317.826.7200
r�
NOIES: �
1)All eroelon contrd meaeuree muet�tia mahtalnetl and Nnctlonal through conetruotfon. _g_ �SnNa SANITARY SEWFn LNE
2) Sedimanl discharya md,trackhg hqn Jot ehdl ba mhlmized. Sedlmanl which ledies �he sita muet
ba clemed up dally and hauled to m approprlate locatlon. SeElmait muet ba ewapt from eiraeis, —$�— t7aSnNC Stonu �u�E
not fluehed. � SF_ aT�axa at
3) Canelructlon Entmnce must 6e mahtafned and/ or top d�eeaed os needed ta mfnlmlze aed}nent 9.T SOq(PEPoMEmt PROlEC71O1
Gom leadnq 1he s1le. � AREA TO REaWN UNq9Nl�m
4) AdJacant lois dfsturbed by an indlvWual bt opamtu muet be repalred and etabOl:ed. w
5) Chanyea a devlatfaie to thfe plon shull 6e submllied to ihe Coimel Stormvatx Ul➢Ry Servfcee hr � q�qB NIET PROffC110N
approwl.
8)The tndivldual lot opxator le roeponeble far Inetallation and malntenmce of all aoslan and . /�pFA ptNN/MAMiQE INET PAUiEC110N
eedlment contrd meaeure untll the lot le ffiab�lied. The aperator must comply wfth all
requlrementa of�. Ihe sionn waia manogemmf�vdinance oF Carmd, Indkna. � – DRAINACE�ROW AAROp
7) Area draln /manhde proiectfon muet alao be ueed for emltary manhdee for protecilan during O gpp
hano conetructfon.
B) Fmnt loi Ihee 3iall have non–wa�en allt fence. Badc lot llne moy 6e w�en ar nm–wovm e1t � PERNAXEN7 SEED
fence.
CONSIRUCTION DRIVE � ��R��X��� ���
Tnnparvy canetrudian drive to comply wlth Carmef Storm Woter �} —'–O0O` ���
Managemenl Ordlnance. LOT it 56 � SpL 9TOC7�lE PItO7FC710N
GENTI.E SWALE STATEMENT - - - - - - s�a-suAV�a oneH
Cenlla�.5wale requlred to be coneWeted priar to lal stabllhatlon (ar to � PAO EIEVAlION
he prvieded if mitaqng along side lot-ilne) during constructkn ond ia
romaln paet–coneiructMn to dlroct aheet:dralned wularehed Eowa�dethe Tha owrall ro efte o erator ror 7HE
front and back of lot and not towarde exiatinq a propoeed roeldmce. P !� P
NEADOWS AT 1NE LEGACY – SECTION 2'
Oparator Nama Kenny Wndler
, Company name: R. H. of INDIANA
Addr'ese:. 9025 N, ftiver fload, Sulte 100
.. Indionapdis, Indiana 4624�
i � Phone �: (317) 846-42W
135.00' I I
I � � I � i �� � I �
I • �
y a
I � I •
� -� � � �
� � I-^ -�
� � � �� ��
I� �� �� � I Mwmed Nor1h
I � I � � � � �
� I � � S � m o - ` � �,� ,. _ ,�.
� �+ ° i
I � ��I � � I ��� ��� � .
� � �I � �� �� �� - .
I � Erosion Controf Ce-kification:
Q I hcaby Ceritfy That 1he aoelon and
� Q I � eedfinent cmtrd meaeuree for thle lot
I I�� 135.44' � Qe�cansfsteit vfth the Erosim Cmird
Plm Mr the ovemll develapment
I � I
0
� ' �� �� I � \\\\.\�\Sn�mL���nuG„��////
/ / N / V'� ti � � � I � 0����G\5 TE/��:. ����
i .
s ' N0. °`:. ;
_ � � .�� ��� � ` = 50303: = _
, � I � = STATE OF ;� �
�
- � il � �NOIA�'\P:'0���
� � �,�q,1;�-.,,,,��� � ���
� / ''/i0",�rquS,URmu�po\"`\o
�
/ ,,,��
�_ �.
EROSION CONTROL AND SEDIMENT PLAN SCALE: 1"=40' Job # 14.0109903
Prepared For:� R.H. OF IN�IANA
Suhdivision: THEMEADOWSATTHELE('i4CYSECTION-2 LOT35
Recortling Info: 2014014218�antl�C.O.C. 201401H979 La Size: 9,077 SF
County: HAMILTON �Trnvnship: CLAY Sec/Twp/Rng: SEC 22-T1BN-R4E
Street AtltlrPSS: 14067 KNIGHTSTO4VN DRNE EAST,CARMLI IN 46033 R/W:50'
8uyer/OwneY: RAGHU 8. IMMADISETTY
Preperetl 8y: JAW DATL 07-11-14