HomeMy WebLinkAbout14070135 Sq. Ft. ���'�af Cqq
x.Mfi. i
'flf'-r ��` � SINGLE FAMILY/ TOWN HOME / TWO-FAMILY
PERMITTING PROCEDLIRES
1\�°!"�/ New Structures� Additions� Remodels, Garages, & Accessory Structures
StIBMITTAL REOtIIREMENTS:
1. COMPLETED RESIDENTIAL IMPROVEMENT LOCATION PERMIT APPCICATION, (ILP) which also
includes the reverse side (or 2nd page) of this procedure sheet.
2. CONSTRUCTION PLANS: At least one set of[he plans should be on paper no larger than 11 inches by 17
inches. If this is not possi6le an electronic PDF copy of plansshould be emailed to nmishlerC�carmel.in.qov , or a disc
containing the electronic PDF copies shall be submitted, in addition to the paper copies.
NEW MAIN STRUCTURES / ADDITIONS / ACCESSORY STRUCTURES,TWO SETS OF PLANS FOR SINGLE FAMILY,
TWO-FAMILY, AND TOWN HOMES, MUST BE SUBMITTED.* THESESHOULD INCLUDE:
-Building Elevations -Foundation Plan -Floor Plans -Typical Wall Section
-If Manufactured Trusses are used, truss diagrams must be included with the building plans. Truss diagrams must be
STAMPED with the seal of the registered architect or engineer who is responsible for that design. ONLY Indiana
registrations will be recognized.
-A SITE (OR PLOT) PLAN SHOWING THE FOLLOWING REQUIRED INFORMATION:
a. Name and address of designer of plan, with date, Name and address of property owner
b. Lot number and subdivision name, or applicable general description
c. Lot drawn to scal�all dimensions: Including Lot/Property lines
d. Minimumfirontbuilding setbaek line, perapproved developmentplan (include all front yard)
e. All roads, alleys, sidewalks, driveways, rights-of-way, etc..:
f. Any applicable flood plain area (Certificate of Elevation, if necessary)
g. Building pad elevation and lot corner elevations
n. All accessory buildings / structures –existing or proposed
i. Sewer and water lines, septic system, (tanks &filed system) and/or well locations
j. All drainage swales and subsurface facilities, dreinage flow arrows (retention / detention areas, etc...)
k. Sump pump -- Show sump pump pit(s) and discharge line locations
I. Geothermal heat pump discharge locations
*NOTE: If land is notwithin a platted subdivision, a legal description is required.
-ONE (1) COPY OF THE SUBDIVISION CONSTRUCTION/DEVELOPMENT PLAN IS REQUIRED—FOR NEW DWELLING
UNIT STRUCTURES ONLY. Sometimes referred to as an "as-built,"this plan sliould show the lot, the surrounding lots,
the building pad or building pad elevation, and the ground topography lines. Plans for the entire subdivision are NOT
required.
-If large equipment is being used, an approved Right of Way Permit from City of Carmel Engineering Office is required.
Please contad the Engineering Office at; (317)571-2441.
*NOTE: For all Town Mome submittals two full sets of construction documents need submitted per Building covering all
options of each unit within the building, along with the State Design Release.
REMODELS. TWO (2) SETS OF'PLANS MUST 8E SUBMITTED AND SHOULD INCLUDE:
-Floor Plans -Typical Wall Section
3. SEWER AND WATER PERMITS FOR NEW STRUCTURES OR ADDITIONS OVER 1,000 SQ. FT. Please
determine which utility company provides services to your construction site, and provide a copy of the uti�ity permit.
a. Carmel Utilities: (317) 571-2443. A sewer and/or water permit should be purchased at the office of Building &Code
Services, prior to or at the time you are submitting your building permit application.
b. Clav Township Reqional Waste District; (317) 844-9200.
. c. Hamilton Countv Health Deot. (for wells.and/or septic permits); (317) 776-8500
FURTHER NOTES / NOTICES: ' ' '
�: CARMEL ZONING ORDINANCE Z-289, SECTION 29.04.02 (3): "The Director shall approve or deny the Improvement Location Permit
within five(5) working days of[he receipt of the written application form and accompanying materials. The Improvement Location
Permit shail be issued when the proposed structure, improvement, or use and�its location conform in all respects[o this ordinan�e."
: IN ADDITION TO THE ABOVE-LISTED SU8MITTAL REQUIREMENTS, THE BUILDING INSPECTOR SHALL BE PROVIDED INFORMATION
RELATIVE TO COMMIfMENTS MADE IN THE ZONING PROCE55 FOR THE PROPERTY INVOLVED. THIS INCLUDES ANY PLAN
COMMISION, BOARD OF ZONING APPEALS,AND/OR DEPT. OF COMMUNITY SERVICES ADMINISTRATIVE APPROVALS REQUIRED:
: ADDITIONAL INPORMATION MAY BE REQUESTED BY, AND SHALL BE PROVIDED TO THE BUILDING INSPECTOR, IF THE
SUBMITTED PLANS ARE NOT OF SUFFIGIENT IN CLARITY OR DETAIL,TO INDICATE THE NATURE AND EXTENT OF THE WORK
PROPOSED AND TO DETERMINE COMPLIANCE WITH ALL APPLICABLE CODES AND ORDINANCES. PLEASENOTE: IF ADDITIONAL
ITEMS FOR REVIEW ARE REQUESTED, REVIEW TIME MAY BE EXTENDED.
> ALL CONSTRUCTION IS�SUB7ECT TO FIELD INSPECTION,AND SHOULD NOT BEGIN PRIOR TO THE ISSUANCE OF THE
BUILDING PERMIT. ONCESHE PERMIT IS ISSUED,WORK SHOULD NOT BE POURED, INSULATED/COVERED, AND/OR.00CUPIED
PRIOR TO THE APPROPRIATE INSPECTION. Beginning prior to obtaining a.building permit and/or proceeding with mnstruction
beyond the�stage of a required inspection withoutapproval constitutes Late Fee penalties, per Z-289 of the Carmel/Clay Zoning
Ordinance; 29.06.07,and 29.06.08.
BUILDWG & CODE SERVICES; CITY OF CARMEL. One Civic Square; Carmel, IN 46032.. Ph. (31 7) 571-2444.
Provide Sq. Ft. for entire structure for new single family home, if remodeling or adding an addition/ accessory structure
provide Sq. Ft. of work area:
BASEMENT 1�` Floor 2nd Floor 3rd Front Rear Total Sq. TOTAL
(Finished aod Floor Porch -Porch or Ft:of
Unfinished) Sunroom Garages
,`�ni5l�- 61?� 1 R l09 2255 N�i4 �� `J � � r/� !o� 'Z�l
Unf;n�s� 5la0
17�3
Per the Adopted Indiana Energy Code that will be in effect for all New Buildings, Additions, Accessory Structures, and
Remodels. There are three methods of compliance to choose from. It is.REQUIRED to indicate which compliance
that will be used at time of submittal. Please seiect from the following:
(Handout for Compliance of EnergyCode can be picked up in our office or found at: htt�://www.carmel.in.gov/ )
Presc�ipti e(o t{est�idrve) " ° �
��tt3 '� �'���k��, � �!� xa
Total UA (allowsbuilding
envelopetrade-offs)
-�e-�-�
Pe��manc�e(mosE�fl�ible)�.;�� �� "'� a y'_�f .
�' � '" '° '� . :As :�i��� d
I, the undersigned, certify that all of the above listed information is shown completely and accurately on the attached plot or site
plan(s), construction plans, and any other submitted documentation, submitted with the building permit application to the City of
Carmel/ Clay Township Department of Communiry Services. I further certify that the joinin9 of water supply piping shall be made with
lead-free solders and Fluxes. Failure to comply will result in a replacement of the system. (Plumbing Code P-509-5) Under the
penalties of Perjury (Indiana Code 35-44-Z-i), Ialso hereby a�rm, under oath, that all of the information I have provided in the table
below is true and accurate, to the best of my knowledge and belief, and that I have not knowingly or intentionally provided or omitted
any informa[ion that would tend to hide, obscure, or otherwise mislead the Dept. of Community Services regarding the truth of the
matters addressed therein.
��� . �� �/�. ��l�
APPLICANT'S SIGNATURE ' DATE
� �f�� �� No right of way permit needed.
Print