Loading...
HomeMy WebLinkAboutFlixBrewhouse Merchants Sq Plumb Permit Issue.pdf. . . . �, - THE WORK INCLUDES MODIFICATION TO THE EXISTING PLUMBING SYSTEM AND PROVIDING NEW MATERIALS, FITTINGS AND ACCESSORIES NECESSARY FOR A COMPLETE FUNGTIONING PLUMBING SYSTEM. THE WORK ALSO INCLUDES ROUGH–IN AND FINAL CONNECTIONS TO FOOD SERVICE EQUIPMENT AND BEVERAGE DISPENSING EQUIPMENT PROVIDED BY OTHERS. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND/OR ORDINANCES AND IS SUBJECT TO INSPECTION. HOOK–UP CHARGES, PERMITS AND ALL OTHER EXPENSES RELATED TO A COMP�ETE AND FUNCTIONING PLUMBING SYSTEM ARE INCLUDED AS A PART OF THIS SECTION. THE INTENT OF THE DRAWINGS IS TO INDICATE THE GENERAL EXTENT OF WORK REQUIRED FOR THE PROJECT. THE DRAWINGS FOR PLUMBING WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, IYPE, FIXTURES AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. REFER TO MANUFACTURER°S STANDARD ROUGH–IN DRAWINGS FOR PLUMBING FIXTURE INSTALLATION REQUIREMENTS AND COMPLY WITH ALL APPLICABLE ADA INSTALLATION REQUIREMENTS. COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PR4JECT SITE. PIPING SYSTEMS – GENERA�: ALL PIPING SHALL BE RUN PARAL�EL TO BUILDING LINES AND SUPPORTED AND ANCHORED AS REQUIRED TO FACILITATE EXPANSION AND CONTRACTION. ALL PIPING SHALL BE CONCEALED EXCEPT IN UNFINISHED SPACES. INSTALL AS REQUIRED TO MEET ALL CONSTRUCTION CONDITIONS AND TO AI.LOW FOR INSTALLATION OF OTHER WORK SUCH AS DUCTS AND ELECTRICAL CONDUIT. AT ALL CONNECTIONS BETWEEN FERROUS PIPING AND NONFERROUS PIPING PROVIDE AN ISOLATING DIELECTRIC UNION. ALL HANGERS SNALL BE COMPATIBLE WITH PIPING MATERIA� TO PREVENT CORRQSION. PROVIDE ALL FITfINGS, ACCESSORIES, OFFSEfS, AND MATERIALS NECESSARY TO FACILITATE THE PLUMBING SYSTEM'S FUNCTIONING AS INDiCATED BY THE DESIGN AND THE EQUIPMENT INDICATED. FIXTURES/EQUIPMENT FURNISHEQ BY OTHERS: PLUMBING CONTRACTOR SHALL PROVIDE UTILITY CONNECTIONS REQUIRED SUCH AS WATER, GAS, SUPPLIES, WASTE OUTLET AND TRAPS AT A�L PLUMBING TYPE FIXTURES OR EQUIPMENT FURNISHED BY OWNER, GENERAL CONTRACTOR, FOOQ SERVICE CONTRACTOR AND EQUIPMENT SUPPLIER. INCLUDED ARE STOP VALVES, ESCUTCHEONS, AND CHROME P�ATED BRASS TUBING WITH COMPRESSION FITTINGS. SANITARY SEWER AND GREASE WASTE PIPING: PROVIDE ALL DRAINS AND PIPING WITHIN THE PROJECT SPACE WITH CONNECTION TO THE EXISTING DRAINAGE SYSTEMS ON–SITE. SANITARY DRAINAGE PIPING ABOVE FLOOR SNALL BE HUBLESS CAST–IRON PIPE AND �ITTINGS AND CONNECTIONS. SANITARY DRAINAGE PIPING BELOW GRADE SHALL BE SERVICE–WEIGHT HUB AND SPIGOT TYPE CAST–IRON WITN NEOPRENE GASKET JQINT SYSTEM. ALL QRAINAGE PIPING SHALL BE UNIFORMLY PITCHED AT 1 j4" PER FOOT FOR PIPE SIZES 3" AND SMALLER AND 1/8°' PER FOOT FOR PIPE 51ZES 4" AND I�,RGER, UNLESS OTHERWISE REQUIRED BY EXISTING CONDITIONS, OR INDICATED ON THE DRAWINGS. NO PVC IS AL�OW FOR WASTE PIPING CONNECTED TQ THE DISHWASHER. SANITARY VENT PIPING: PROVIDE A COMPLETE SYSTEM QF STANDARQ WEIGHT CAST IRON NO–NUB PIPE AND FITfINGS. THE VENT SYSTEM SHALL BE CARRIED THROUGH THE ROOF WITH APPRQPRIATE FLASHING. CONDENSATE AND INQIRECT DRAIN PIPING: TYPE M COPPER TUBING UP TO 1" ID, TYPE DWV COPPER TUBBNG AND FIITINGS FOR 1-1/4" AND IARGER SIZES. CLEANOUTS: PROVIDE CLEANOUTS AT THE END OF EACH NORIZONTAL RUN, AND AT THE BASE OF ,4LL VERTICAL WASTE AND DRAIN PIPES. CLEANOUTS SHALL BE {7F THE SAME SIZE AS THE PIPES TNEY SERVE, CONFORMING TO CODE REQUIREMENTS. PROVIDE SUITA,BLE WA�� QR FLOOR CLEANOUTS WITH ACCESSORlES TO O�SCURE FROM VIEW. WATER DISTRIBUTION PIPING: LAYOUT WATER PIPING 5Q THAT THE ENTIRE SYSTEM CAN BE DRAiNED. ABOVE GRADE NOT AND COLD WATER PIPING SHAL� �E 1 j2" MiNIMUM TYPE �. COPPER TUBING 4VITN WROUGHT COPPER FIl-I'INGS Ah1D SWEAT CONNECTIONS. BELOW GRADE HOT AIVD CQLD WATER PIPING SHALL BE 1 j2" MINIMUM TYPE K COPPER TUBING WITH WROUGHT COPPER FITfINGS, AND SWEAT CONNECTIONS. PROVIDE lNATER HAMMER ARRESTERS AT EACH FIXTURE OR GROUP OF FIXTURES AS REQUIRED. INSTA�L CHROME PLATEQ BRASS ESCUTCHEO�! P(�TE� AT A�� PENETRATIONS THROUGH FINISHED SURFACES (1NCLUDING CABINET INTERIORS). USE LEAD FREE 4R TIN–ANTiMONY SOLDER, 95f5 FOR AL� SWEAT FITI'INGS OF COPPER PIPING. PIPE I�SULATI4N: RIDGE ONE–PIECE FIBERGLASS PIPE INSULATION WITH REQUIREMENTS COMPLYING WITH ASTM C 547, SELF–SEALING ADHESIVE LAP LONGITUDINAL JOINTS AND BUTf STRlPS FOR TRANSVERSE JOINTS. JACKETING SHALL CONFORM TO ASTM C 1 i 36, TYPE I, MAXIMUM VAPOR TRANSMISSI�N RATING OF 0.02 PERM WHEN TESTED ACCORDING TO ASTM E 96, PRQCEDURE A. (K VALVE) 0.25 BTU/IN. f NR. * Ff2 *°F AT 75°F MEAN TEMPERATURE WITH A MINIMUM R–VALVE OF R4. PRQVIDE INSULATION THICKNESS AS INDICATED: DOMESTIC COLD WATER PIPING 1" AND SMALLER: 1/2" THICKNESS, DOMESTIC COLD WATER PIPING 1-1/4" – 2": 3/4" THICKNESS. D4MESTIC COLD WATER 2-1 /2" AND LARGER: 1" THICKNESS. PLUMBING VENT PIPING WITHIN 6 FEEf OF ROOF OUTLET: 1'° THICKNESS. STORM WATER PIPING: 1" THICKNESS. OVERF�OW STORM WATER PIPING: 1" THICKNESS. CONDENSATE PIPING: 1/2" THICKNESS. DQMESTIC HOT WATER PIPING 2" AND SMALLER: 1" THICKNESS. DOMESTIC HOT WATER RETURN PIPING: 3/4" THICKNESS. WATER AND WASTE PIPING BELOW HANDICAP LAVATORIES/SINKS. PIPE INSULATION: FLEXIBLE, ONE PIECE, EXPANDED CLOSED–CELL ELASTUMERIC PIPE INSULATION WITH REQUIREMENTS COMPLYING WITH ASTM C 518, SELF–SEALING> WITH A MAXIMUM VAPfJR TRANSMISSION RATING OF 0.20 PERM WHEN TESTED ACGORDING T� ASTM E 96. THERMAL CONDUCTIVITY (K VALVE) SHALL NOT EXCEED 0.27 BTU/iN./HR. * FT2 *'F AT 75'F MEAN TEMPERATURE WITH A MINIMUM R–VALUE OF R3,7, AND INSULATION AND JACKET SHALL BE RATED FOR OPEFiATING TEMPERATURES FROM 40'F TO 180' F. PROVIQE INSULATION THICKNESS AS lNDICATED: DQMESTIG COLD WATER PIPING 2" AND SMALLER: 1/2" THICKNESS. DOMESTIC HOT WATER PIPING 2"' AND SMALLER: 1/2" THICKNESS. SANITARY PIPING 2" AND SMALLER: 1 f 2" THiCKNESS. CONDENSATE PIPING; 1 /2" THICKNESS. SHUTOFF VALVES WITH UNIONS SHA�L 8E PROVIDED FOR SERVICE TO EACH P�UMBING FIXTURE, FOOD SERVICE EQUIPMENT ITEM OR OTHER EQUIPMENT ITEMS TO FACILITATE ISOLATION FOR REPAIR OR REPLACEMENT. PIPE LINE VALVES SHA�L BE EQUAL TO CRANE SERIES #9202, QUARTER TURN BALL VALVE. CONSTRUCTION – TWO PIECE, BRONZE BODY, FUL� PORTED, CHROME PLATED BRASS BA�L, REPLACEABLE 'iEFLON OR TFE" SEATS AND SEALS. RATING – 150 PSI WSP, 600 PSI WOG. GONNECTIONS – SO�DER OR THREADED ENDS TO MATCH PIPING. STANDARDS COMPLIANCE – BRONZE OR BRASS VALVES: MSS–SP-110. WHEN SHUTOFF VALVE ARE PLACE IN THE CEILING THE VA�VES WILL BE LOCATED AT A MAXIMUM OF 12°' ABOVE THE CEILING, AND NOTHING SHALL BE PLACE BETWEEN THE CEILING ACCESS AND THE VALVES. ACCESS PANELS SHA�L BE PROVIdED WHERE CONCEALED CONTROL DEVICES AND VALVES ARE CONCEA�ED WITHlN WAL�S. WHERE ACCESS FOR ADJUSTMENT AND MAINTENANCE IS POSSIB�E THROUGN LAY–IN SUSPENDED CEILINGS ACCESS PANELS ARE NflT REQUIRED. INSTA�lATION: THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION. CAP PIPE QPENINGS TO EXCLUDE DIRT UNTIL FIXTURES ARE INSTALLED AND FINAL CONNECTIONS HAVE BEEN MADE. PROCEED AS RAPIDLY AS CONSTRUCTION WILL PERMIT. SET FIXTURES LEVEL AND IN PROPER ALIGNMENT. INSTALL SUPPLIES IN PR4PER ALIGNMENT WITH FIXTURES. INSTA�i. SILIGONE SEALANT BETWEEN FIXTURES AND ADJACENT MATERIAL, FOR SANITARY JOINT, AND OMIT ESCUTCHEONS. REPAIR EXISTING PLUMBlNG SYSTEM COMPONENTS DAMAGED BY CONSTRUCTION OPERATIONS AND RESTORE TO ORIGINAL CQNDITIONS. TEST WATER SYSTEM UNDER 150 PSIG HYDROSTATIC PRESSURE, FOR FOUR {4) H4URS MINIMUM. WHEN TESTING INDlCATES MP,TERIALS OR WORKMANSHIP IS DEFICIENT, REPLACE OR REPAIR AS REQUIRED, AND REPEAT TEST UNTIL STANdAR�S ARE ACHIEVED. iEST SANITRRY DRAINAGE AND VENT SYSTEM BY FI�LING WITH WATER, WITH ALL F'OINTS !�! THE SYSTEM BEING SUBJECT TQ PRESSURE OF AT �EAST 1 fl' OF WATER. WA�ER LEVEL SHALL REMAIN STATIONARY FOR A PERIOD C1F ONE HOUR, WITHOUT ANY PIPE OR JOINT LEAKAGE. IF TESTING ihiDICATES DEFICIENTS REPLACE OR REPAIR AS REQUIRED, AND REPEAT TEST UNTI� STANDARDS ARE ACNIEVED. PROViDE A COMP�EfE GAS PIPING SYSTEM TO SERVE NEW GAS FIREa HVAC EQUIP�9ENTy DONIESTIC WATER HEATER°S AND EQUIPN3ENT FURNISHED BY OTHERS, AS NOTED ON THE DRAWINGS. PROVIDE EITHER THREADED STEEL OR MALLEABLE IRON PIPE WITH MAL�EAB�E FITfINGS aR WELDED STEEL. PROVIDE ALL UNIONS, SHUT–OFF VA�VES AND D1RT LEGS REQUIRED BY NFPA-54 AND GOVERNING �OGAL CODES AND AT EACH GAS APPLIANCE CONNECTION. PROVIDE ALL TESTS, METERS, INSPECTIONS, HANGERS AND EQUIPMENT CONNECTIONS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. �c�i I L COLD HOT FIXTURE WATER WATER WASTE VENT WATER GLOSET (FLUSH) 1-1 /4" – 4" 2" URINAL (FLUSH VALVE) 1°' – 2" 1-1/2" LAVATORY 1/2" 1/2" 1-1 f 2" 1-1 /2" MOP BASIN 1/2" 1/2" 3" 1-1 /2" WATER COOLER 1/2" – 1-1 /4" 1-1 /4" HAND SINK 1/2" 1/2" 1-1/2" 1-1/2" KITCHEN SINK 1 f 2" 1/2�� fND – FLOOR DRAIN/SINK & TRENCH DRAIN – – 2"/3" 1-1 /2" FLOOR SINK – – 4'° 2" KITCHEN EQUIPMENT (AS REQUIRED) 1/2" 1/2'� – – WALL HYDRANT 3/4" – – – HOSE BIBB 3/4'° – – – SIZES ARE MINIMUM BRANCH SIZE TO FIXTURE. I I 1 THIS SCHEDULE IS A PARTIAL LISTING OF THE EQUIPMENT SUPPLIED BY THE FOOD SERVICE EQUIPMENT CONTRACTOR (FSEC). REFER TO FSEC OF�AWINGS FOR A COMP�ETE L9STING OF EQUIPMENT, TYPES, SIZES, AND LOCATIONS. PLUMSING CONTRACTOR (PC) TO PROVIDE NECESSARY ITEMS TO INSTALL FSEC EQUIPMENT (INCLUDING VALVES, UNIONS, FITTiNGS, EI�C.) TO MAKE COMPLETE SYSTEM. THIS �ISTING DOES NOT SUPERSEDE THE FSEC DRAWINGS. � SODR DISPENSER 197 DISH MACHINE 11 GLASS FILLER 198 SOILED DISH TABLE 12 DRIP TRAY 199 PRE–RINSE FAUCEi' 13 DUMP SINK 204 SQILED DISH SBNK 14 DUMP SINK FAUCET 205 PRE–RINSE FAUCET 15 COFFEE BREWER 206 DISPOSER 19 HAND SINK 213 DISHMACHINE WBTH BOOSTER 20 HANQ SINK FAUCET 221 SODA DISPENSER 51 FI�L FAUCEf 232 COFFEE BREWER 52 HOT FOOD WELL 235 GLASS FILLER 60 COLQ PARI 236 DRIP TRAY 71 h�AKE–UP AIR UNIT 237 DUMP SINK 73 CONVEYOR OVEN 238 NAND SIiVK 81 H,4ND SINK 246 HA�1D SINK �6 �fAKE–UP AIR UNiT 247 HANfl SINK FAUCEf 90 C4NVECTI4N OVEN 248 50DA DISPENSER 92 6 OPEN BURNER 254 DUMP SINK 95 FRYER 256 COCKTAIL STATION 105 GRIDDLE 258 DRAIN BOARD 107 GRIDDLE 259 HAND SINK 108 OPEN BURNERS 261 DUMP SINK 115 MAKE–UP AIR UNIT 262 GLASS WASHER 126 PREP SINK 264 DRAIN BOARD 127 PREP SINK FAUCET 265 DRY STORAGE CABINET 131 HAND SINK 267 DRAIN BOARD 151 COOLER C01� 268 DUMP SINK 153 FREEZER COIL 270 COCKTAIL STATION 155 COOLER COIL 272 ORAIN BOARD 161 COOLER COIL 273 HAND SiNK 166 ICE MAKER 274 4 COMPARTMENT SINK 167 ICE BIN 277 COCKTAIL STATION 169 ICE MAKER 279 DUMP SINK 170 ICE BIN 280 ORAIN BOARD 172 WATER FlLTER 281 HAND SINK 173 FLOOR TROUGH 283 DRIP TRAY 176 CARBONATOR 284 GLASS RINSER 177 NITROGENATOR TANK 292 DRIP TRAY 178 3 COMPARTMENT SINK 293 GLASS RINSER 179 3 COMPARTMENT FAUCET 295 DRIP TRAY 181 DISPOSER 296 G�ASS RINSER 187 HAND SINK 297 DRIP TRAY . , �, � A. CONTRACTORS AND SUB–CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUGTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSEQ THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATE�Y DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. B. GOORDINATE WITH TNE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE GONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. PROVIDE PIPE RISES, DROPS, AND OFFSETS AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION. NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. C. DRAWINGS FOR PLUMBING WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL �OCATION, IYPE, LAYOUT AND EQUIPMENT REQUIRED. THE DRAWINGS SHAL� NOT BE SCALEQ FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE PIPfNG, CQNNECTIONS, FITfINGS, VALVES, OFFSETS AND ALL MATERIALS NECESSARY FOR A COMPLEfE SYSTEM. D. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS APPROVED AND AMENDED BY THE GOVERNING CITY AND THE AUTHORITY HAVING JURBSDICTION. PURCHASE ALL PERMITS ASSOCIATEQ WITH THE WORK. OBTAIN ALL INSPECTIONS REQUIRED BY CODE. E. PROVIDE WATER HAMMER ARRESTORS THROUGHOUT WATER SYSTEMS AS REQUIRED PER °'WATER HAMMER ARRESTERS" DEfAIL. F. PROVIDE BACKF�OW PREVENTION DEVICES IN WATER LINES FEEDING PLUMBING FIXTURES AND/OR EQUIPMENT AS SHOWN ON PLANS AND ELSEWHERE AS REQUIRED BY AUTHORIIY HAVING JURISDICTION. USE DEVICES OF APPROVED MANUFACTURER AND TYPE IN ACCORDANCE WITH REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. G. CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION. IF PRESSURE AT BUI�DING ENTRY PRIOR TO ALL LOCALLY REQUIRED DEVICES IS LESS THAN 60 PSIG STATIG, CONTACT flWNER'S REPRESENTATIVE. IF PRESSURE EXCEEDS 80 PSIG, PROVIDE PRESSURE REDUCING VALVE. H. SUSPEND HORIZONTAL SERVICE PIPING FR4M UNDERSIDE OF ROOF OR FLOOR STRUCTURE UNLESS OTHERWISE INDICATED. INSTALL PIPING AS HIGH AS POSSIBLE. EXTEND PIPING DOWN IN WALLS, PARTITIONS AND CHASES TO SERVE FIXTURES AND EQUIPMENT. I. VERIFY SERVICE CONNECTION POINTS, SIZES, ELEVATIONS AND METERING LOCATIONS FOR PROJECT WITH LOCAL UTILITY COMPANIES ANDfOR CIVIL ENGINEER, AS APPLICABLE. J. REFER TO OTHER PORTIONS OF PLANS AND SPECIFICATIONS FOR ADDlTIONAL INFORMATION ABOUT ITEMS FURNISHED AND WORK p�R�nRnA�n RY Fnnn �Erayi�� �n�JIPAAFNT �(1NTRA( T(lR ;FCFr�, VfR�1=Y ROUGH–IN AND CONNECTION REQUIREMENTS WITH FSEC SHOP DRAWINGS. K. COMPLY WITH LOCAL HEALTH DEPARTMENT REGU�ATIONS. OMIT ESCUTCHEONS IN F000 SERVICE AREAS. SEAL PIPES NEATLY WITH GROUT AT WAL�, FLOOR, OR CEILING PENETRATIONS. OMIT INSULATION ON EXPOSED PIPING BEHIND AND UNDER EQUIPMENT. PROVIDE CLEARANCE BEHIND AND UNDER EXPOSED PIPING AS REQUIRED BY HEALTH DEPARTMENT. WHEREVER P05SIBLE, INSTALL PIPING IN FOOD SERVICE RREAS CONCEALED. CONFORM TO HEALTH DEPARTMENT REQUIREMENTS FOR LOCATIONS OF FLOOR SINKS. L. USE OF G4MBUSTIBLE MATERIALS IS NOT ALL4WED IN THE RETURN AIR PLENUM. MATERIALS USED IN THE PLENUM SHALL HAVE FIAME SPREAD RATING NOT TO EXCEED 25 AND SMOKE DEVELOPED RATING NOT TO EXCEED 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. 1. THE ABBREVIATI4N GC, WNEREEVER IT APPEARS IN 1"HESE DRA1NlNGS, SHALL REFER TO THE GENERAL CONTRP,CTflR. 2, THE CONTRACTOR FOR THIS DIVISION QF WORK IS REQUIRED TO READ THE SPECIFICATIQi�S A,ND REVIEi�/ DRAWINGS FOR ALL �IVISI4NS OF 1NOftK AND IS RESPONSIBLE FOR THE COQRQINATION OF THlS 1N�RK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. iT IS THIS CONTRACTOR'S RESPONSIBI�ITY TO PROVIDE A�L SUBC�NTRACTORS WITH A CQMPLETE SET OF BID DOCUMENTS. 3. F1RE PROTECTION P�ANS AND SPRlNKLER DRAWINGS SHA�L BE ENGINEERED AND WEf SIGNED BY A LANDLORD APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCA� JURISDICTION. FiNAL INSTALLATION MUST COMPLY WITH NFPA 13 AND STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 4. COORDINATE SPRINKLER HEAD LAYOUT AND PIPE ROUTING WITH ARCHITECTURAL PIANS, STRUCTURAL PLANS, HVAC CONTRACTOR, ELECT�ICAL CONTRACTOR AND THE GC. THIS CONTRACTOR SHALL INCLUDE IN THE 81� AND BE RESPONSIBLE FOR EXACT QUANTITY OF SPRINKLER HEADS FiEQUIRED FOR COVERAGE AND FINAL APPR4VAL. 5. THIS FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SH4P DRAWINGS AND CALCULATIONS FOR THEIR WORK. SUBMIT TO THE GC FOR ARCHITECTURAL APPROVAL OF HEAD LOCATIONS AND TYPES. 6. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMII-fING COQRDINATED DRAWINGS, HYDRAULIG CALCULATIONS, HEAD TYPES ANQ CQLORS TO A�L AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVEQ. 7. SPRINKLER PIPING SHAL� NOT RUN THRU THE THEATER SOUND WALLS OR FROM THEATER TO THEATER. SPRINKLER PIPING WILL ONLY ENTER THE THEATER ONCE AND SERVICE THAT THEATER ONLY. REFER TO ARCHITECT DRAWING FOR THE�TER SOUND WALLS. 8. SPRINKLER HEADS TD MATCH COLOR OF THE SURROUND AREAS. EXAMPLE: BlACK IN THE THEATER, CHROME PIATED IN NON–PUBLIC SPACE. VERIFIED WITH ARCHITECT FOR COLOR AND ADDITIONAL INFQRMATION. . . . � �, � . . : i •1 ft: i• � ff. S ! a � � w �'.,. �. r. � . � a s l, , • 4; i'i •� •� . �. � .- . r • � � c� �� e �-� � � c� •�� � �-� . ,-r � � . r - « •• • i • � • : � � • � ! ' i �i i i `< i .! •• �. a,, . � � � ��� ■� � . /. �l.� . � �. � � c. / �r�. .!� �.� s • • • , • • � � �• , .. �r :- r • � : ! i :• : � ` i � ' i i' : # R : S" i'. .. � � � .. � r -� r �- . � �-� � -. �- � ..� � , . .• . •. . � � � .� . �.� y i ! .. ♦ � . � .R 1 � . : i � .. � � � �. , r. �� � �� s�.. y E .� r� l��.. � � ,. i . � , . ..� � � . . � «- . . • ; ! � # # • • , i • ! ► !� • � • � �!• .r , � � .. � a i , . � a. :.. M �s a t �. .. � �. � . •t ;- .. t r.. � �.�'. �.��� a � ,� �..� � � ���.�� � �..� � �/ �����. s . ... r r � • '� ' f s * �, � � �..•� � ► ��... * r . .. : _ � � � . � s- . .• � • �. . `^ lM - # : '. . � �� + ... ,. . 1 FI E A� WATER CLOSET (FLOOR MOUNT): AMERICAN STANDARD #3451.001.020 A MADERA", WHITE VITREOUS CHINA, 1.28 GPF, ELONGATED SIPHON JET BOWL, 1Y2" TOP SPUD AND RIM AT 15" AFF AND MATCHING DC POWER, SENSOR OPERATED FLUSH VALVE WITH VACUUM BREAKER, ANGLE CHECK STOP, SET SCREW AND ADAPTOR #6065.121.002. OLSONITE #95SSCT OPEN FRONT SEAT LESS COVER WITH SELF–SUSTAINING CHECK HINGE. A1 WATER CLOSET (HANDICAP, FLOOR MOUNT): AMERICAN STANDARD #3461.001.020 "MADERA", WHITE VITREOUS CHINA, 1.2$ GPF, E�ONGATED SIPHON JET BOWL, 1Y2" TOP SPUD AND RIM AT 16Y2" AFF AND MATCHING DC POWER, SENSOR OPERATED FLUSH VA�VE WITH VACUUM BREAKER, ANGLE CHECK STOP, SET SCREW AND ADAPTG�R #6065.121.002. OLSONITE #95SSCT OPEN FRONT SEAT LESS COVER WITH SELF–SUSTAINING CHECK HINGE. FLUSHING OPERATION SHALL BE FROM THE WIDE SIDE OF THE TOILET STALL. OB URINAL: AMERICAN STANOARD #6590.001 "WASHBROOK", WHITE VITREOUS CHINA, 0.125 GPF, WASHOUT FLUSH ACTION, WALL MOUNTED, 3/4" INLET SPUD, FLUSNING RIM, WALL HANGERS AND MATCHING DC POWER SELECTRONIC FL.USH VALVE WITH VACUUM BREAKER AND ANGLE STOP #6063.013.002. RI 24" AFF TO RIM. B1 URINAL (HANDICAP): SAME AS FIXTURE B EXCEPT RI 17" AFF Tfl RIM. C� LAVATORY (CflUNTERTOP): COREAN INTEGRAL LAVATORY BOWL, REFER TO ARCHITECTURAL DRAWING FOR SPECIFICATION. SINGLE HOLE FOR GROHE #34721-001 CHROME LAVATORY FAUCET, REPLACE AERATOR WITH A Q.5 GPM AERATOR. PROVIDE GRID STRAINER DRAIN WITH TAI�PIECE, CHROME–PLATED CAST BRASS P–TRAP WITH CLEANOUT, WASTE ARM TO WAL� WITH ESCUTCHEON AND Y4 TURN ANGLE BALL STOPS WITH METAL HAN��E. INSUTATE WATER AND WASTE PIPING UNDER LAVATORY WITH TRUEBRO °'LAV GUARD2" #102E–Z IF FRONT OF COUNTER IS EXPOSED. �D FLOOR DRAIN (LIGHT DUTY): JR SMITH #2010–NB–P050 CAST IRON DRAIN WITH SQUARE NICKEL BRONZE STRAINER, Y2" TRAP PRIMER CONNECTION AND MEMBRANE F�ASHiNG CLAMP. PROVIDE OUT�ET WITH P–TRAP AND CLEAN AND POLISH STRAINER TOP AF�(ER INSTALLATION. E� MOP BASIN: FIAT #MSB-2424, 24"x24°'x10°' QNE–PIECE MOLDED STONE CONSTRUCTION WITH 3" STAINLESS STEE� DRAIN, #MSG-2424 STAINLESS STEEL WALL GUARD, �83Q–AA SERVlCE FAUCET AND �832–AA HOSE AND HOSE BRACKET. � DRINKING FOUNTAIN (SINGLE): OASIS #F�F110R NON–REFRIGERTEAD STAINLESS STEEL DRINKING FOUNTAIN. PROVIDE Y4 TURN ANGLE BALL STOP WITH MEfAL HAN�LE, P–TRAP WITH C�EANOUT AND WASTE ARM TO WALL. PROVIDE ACCESS PANE� TO STOP VALyE AND P–TRAP. COORDINATE MOUNTING HEIGHT WITH ARCHITECT. �G BREWER FLQOR DRAIN: BY OTHERS. PROVIDE Y2'� TRAP PRIMER CONNECTION AND P–TRAP AND CLEAN AND POLISH STRAINER TOP AFTER INSTALLATIQN. G1 BREWER TRENCH DRAIN: JR SMITH/ACO #9828 SYSTEM, PRECAST CONCRETE, 12'° WIDE SLOPE DRAIN, BOTTOM OUTLET, CLQSING END CAPS AND DUCTILE IRON SLOTfED GRATE FOR HEAVY DUTY (CLASS C). PROVIQE CHANNE�S AS REQUIRED FOR APPROXIMATE 13 FEEI-. PROVIDE 4" DEEP SEAL P–TRAP. �H BREWER HAND SINK: ADVANCE #7–PS-23–EC, WALL MOUNTED, SINGLE COMPARTMENT, STAINLESS STEEL HAND SINK WITH FAUCET WITH A 0.5 AERATQR. PROVIDE Y4 TURN ANG�E BALL STOPS WITH METAL HANDLE, CHROME PLATED CUP STRAINER WITH TAILPIEGE, P–TRAP WITH CLEANOUT & WASTE ARM TO WALL. �J BREWER HOSE BIBB: GHICAGQ FAUCET #952–XKCP, �/4" INLEf, WALL MOUNTED, SHORT SPOUT, VACUUM BREAKER, 3/4" TNREADED HOSE C4NNECTION, 2Y4" TEE N,4NDLE WITH Y� TURN OPERATIQN, CNROME PLATED. MflUNT 36" AFF, VERIFY WITH BREWER DRAWING. K MIXING VALVE: SYM�AONS #7-2i4–CK "MAXLINE", 3/8" I(��ETS AND OUTL.Ef, THERMOSTATIC CONTROLLER WITN INTEGRAL CNECKS, ALL BRASS SODY WITH DUAL STAINLESS STEEL STR,4INER, VANDAL–RESISTANT TEMPERATURE ADJUSTMENT HANDLE. SEf TO 105' AND �OUNT IN ACCESSIBLE LOCATION. ONE SIP�K 4R I.AV ONLY. L FLOQR SINK: JR SMITH �3411-12, CAST IRON BODY, FLASHING CLAMP, ACID RE5ISTANT COATED INTERiOR AND CAST IRON GRATE, 8" SQUARE Y2 GRAiE AND A�UMINUM SEDIMENT BUCKET. PROVIDE OUTLEf WITN P–TRAP. M TRAP PRIMER: PRECISION�/ PLUF�BING PRODUCTS "PRIME–R1TE" #PR-500, AUT�MATIC OPERATION� /'Z99 INLET AND OUTLET. SERVICE UP TO FOUR F�OQR DRAINS WITH DISTRIBUTION UNIT. INSTAL� IN ACCESSIB�E LOCATION WITH PRIMER �OCATED MINIMUM 4F 6" ABOVE FLOOD LEVEL �F FL40R DRAIN RIM. PROVIDE ACCESS PANEL A5 REQUIRED. �N BREWER WATER HEATER: AO SMITH �BTH-150, 100 GALLON STORAGE, 150,000 BTUH GAS INPUT, 173 GPH RECOVERY RATE AT 100'F RISE, THREE YEAR TANKJPARTS WARRANTY, GLASS LINED STEEL TANK, 150 PSI WORKING PRESSURE, MEEfING CURRENT EDITION OF ASHRAE 90.1 B AND LOCAL ENERGY CONSERVATION REQUIREMENTS. PROVIDE T&P RELIEF VALVE AND INSTALL PER MANUFACTURER°S INSTRUCTIONS. N1 BREWER EXPANSI4N TANK: AMTRO� #ST-12–C "THERM–X–TROL'°, TOTAL VOLUME OF 6.4 GALLQNS WITH MAXIMUM ACCEPTANCE VOLUME OF 3.2 GALLONS, 3/4" CONNEGTION. INSTAL� PER MANUFACTURER'S INSTRUGTIONS. N2 BREWER RECIRCULATION PUMP: GRUNDFOS #ALPHA 15-55SF, STAINLESS STEEL PUMP WITH A CAPACITY OF 4 GPM AT 11 FEEf HEAD, 45 WATTS, 115V-14. INSTALL NEAR WATER HEATER PER MANUFACTURER°S INSTRUCTIONS AND NOT OVER 60" AFF. �P RESTROOM WATER HEATER: AO SMITH #DEL-15-4KW, 15 GALLON STORAGE, ONE 4000 WATT HEATING INPUT AT 480 VOLT, SINGLE PHASE SERVICE, THREE YEAR �IMITED WARRANTY, MAGNESIUM ANODE, GLASS–LINED, MEETING CURRENT ED1710N OF ASHRAE 90,18 AND LOCAL ENERGY GONSERVATION REQUIREMENTS. PROVIDE T&P RELIEF VALVE AND INSTALL PER MANUFACTURER'S INSTRUCTIONS. P1 RESTROOM EXPANSION TANK: AMTROL #ST–S–C "THERM–X–TROL", TOTA� VOLUME OF 2,0 GALLONS WITH MAXIMUM ACCEPTANCE VOLUME OF 0.9 GA�L.{�NS, �/4" CONNECTION. INSTALL PER MANUFACTURER°S INSTRUCTIONS, R KITCHEN WATER HEATER: {3)AO SMITH #BTH-250, 100 GALLON ST4RAGE, 250,000 BTUH GAS INPUT, 288 GPH RECOVERY RATE AT 1 �0'F RISE, THREE YEAR TANK/PARTS WARRANTY, GLASS I.fNED STEEL TANK, 150 PSI WORKING PRESSURE, MEEfING CURRENT EDITION OF ASHRAE 90.1 B AND LOCAL ENERGY CONSERVATION REQUIREMENTS. PRQVIDE T&P RELIEF VALVE AND INSTALL PER MANUFACTURER'S INSTRUCTlONS. R1 KITCHEN EXPANSI4N TANK: AMTRO� #ST-30V–C '°THERM–X–TROL", TOTAL VOLUME OF 14.0 GALLONS WITH MAXIMUM ACCEPTANCE VC?LUME OF 8.9 GA��ONS, 1" CONNECTION. INSTAL� PER MANUFACTURER'S WSTRUCTI4NS. R2 KITCHEN RECIRCULATION PUMP: GRUNDFOS #ALPHA 15-55SF, STAINLESS STEEL PUMP WITH A CAPACITY OF 5 GPM AT 9 FEET HEAD, 45 WATTS, 115V-1�. INSTA�L NEAR WATER HEATER PER MANUFACTURER'S INSTRUCTIONS AND NOT OVER 60'° AFF. �S KITCHEN WATER SOFTENER: CU�LIGAN #HCE-210-2, SINGLE SYSTEM WITH PRESSURE VESSE�, SOF�I'ENING RESIN, CONTROL VALVE, BRINE MAKER AND ELECTRONIC GONTROLLER. DESIGN FLOW RATE OF 50 GPM AND A PEAK FLOW RATE OF 76 GPM, 30,OOfl GRAINS PER 15 LB OF SALT. PROVIDE ENOUGH SA�T TO FILL THE TANK AND 1 COMPLEfE REFI �L. OT HOSE BIBB: CHIGAGQ FAUCEf #952, WALL MOUNTED, SHORT SPOUT, VACUUM BREAKER, 3l4" THREADED HQSE CONNEGTION, REMOVABLE TEE HANDLEjSHIELD CAP, CHROME PIATEQ. M4UNT 36" AFF. . : :. � ���►� � �l AFF/AFG BFP CO FFCO/FGCO FSEC IW PC RI TYP UNO VTR WCO (E) '► ��� FW SW F SP T � D OD GW ST --ST-- OST — OST — ABOVE FINISHED FLOOR/GRADE BACKFLOW PREVENTER CLEANOUT FLUSH FLOOR/GRADE CLEANOUT FOOD SERVICE EQUIPMENT CONTRACT�R INDIRECT WASTE PLUMBING CONTRACTOR ROUGH–IN TYPICAL UNLESS NOTED OTHERWISE VENT THRU ROOF WALL CLEANOUT EXISTING EXISTING PLUMBING LINE – SEE DRAWING COLD WATER {CW) COLD WATER {CW) – BELOW SLAB/GRADE FI�TERED WATER SUPPLY (FW) SOFT COLD WATER {SW) FIRE PROTECTION {F) (SPRINKLER/STANDP4PE) F1RE PROTECTION (5P) (STANDPIPE) HOT WATER (HW) 140', 120' TEMPERED HOT WATER (TW) HOT WATER RETURN {HWR) 140°, 120' rAS I INF (f�l CONDENSATE LINE (Q) OVERF�OW CONDENSATE LINE (OD) PLUMBING VENT {V) PLUMBING VENT (V) – BELOW SLABfGRADE SANITARY WASTE (SAN) – BELOW SLAB/GRADE GREASE WASTE (GW) – BELOW SLABJGRADE STORM LINE (ST) – ABOVE SLAB/GRADE STORM LINE {ST) – BELOW SLAB/GRADE OVERFLOW STORM LINE (OST) – ABOVE SLAB/GRADE OVERFLOVJ STORM LINE (OST} – BE�OW SLAB/GRADE E E L EFE E CESf �T T!0 S: CONNEGT TO EXISTING � PLAN NOTE DESIGNATIOi� � EQUIPMENT DESIGNATION � FIRE PROTECTIQN NOTE DESIGNATIQN � FOODSERVICE EQUIPMENT DESIGi�lATION � REVISION DESIGNATlON �--,'�j NVAC EQUIPMENT DESIGNATION L�J . . •�; - �–�O i—�� PIPE TURNING UP/DOWN 2—�0�—�6�� TEE TURNING UPfDOWN i--I��—�i SHUTOFF VALVE {BALL IYPE) i—��i—`� CHECK VALVE i—i��•r—�` BALANCING VA�VE ] END CAP SYMBOLS LEGEND NOTES: REFER TO SPECIFICATIONS AND PLAN NOTES FOR DETAILED DESCRIPTION OF AI.L DEVICES SHOWN IN THIS SGHEQULE, PROVIDED BY THIS CONTRACTOR. THIS SHEET 15 PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY. THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPEGTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABI�ITY FOR THE ACCURACY OF iHESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE REQUIREMENTS. i � . i :�►���►�: Larson Binkley, Inc. 310 W 20th Street, Suite 200 Kansas City, MO 64108 T 816-997-9601 F 816-997-9602 larsonbinkley.com Copyright 2014 J' ` \P,� T' •F�,4 '°'. .°°*Q�°�,,G�S��A� '�S'' : �;:Q o°. � _ � � _ " • No.11300274 � – = . = STATE OF ,;� ; r -o'. � �v ` r9 =, : 4�` `�''o�"''ND I AN.P''G`+�`' `''�SS10N A; `E'�' ts � � ;�, : . � .•;;, � f � . . �" � �' � � �, • � • �1 � . �' , • . . . . � � i � � •• • , • .. . , r . �� � .' � � .` . • � / � DATE: 07. I b.20 I 4 DRAWN BY: ESC F1LE: K:\FlixBrewhouselCarmel\ REV1Si�NS: p _ _ COPYRIGHT 2013 JKR PARTNERS LLC AL� RIGHTS RESERVED � r . _. . �� ; , ���_ - __� _ _. _ _ _ _ � _.. _ ._. .. _..._ � _..._.. TO (E) 15Q0 GALLON GREASE iNTERCEPTOR BY LANDLORD ,., _ �� � a� _ � , �... � � � ,.. `� __. __ __ _ . � __,_. �, _._ _, , _ . � � , , � � \ � ti �. �� �� ,w � � , � �:. � , , , , � _ . _.� ��. ,. ... , . ..., � . .ta _ , : ..,. . �v ,�.. � . .� .. �A� ,'� � � ; , � _ _ __ � _ _ _ _ _ _ _ _ _ _ _ _ _ __. _ _ ., , , a __ : � �� .� \ _ ... .�� �.: VESTIBULE _ __ � 2" VENT UP 01 P1.1 - �� 109A � � � _.... _ .... . ........... _... __......._. _..__._. _...... ._._... ..... __ ..... �. ,... � ,. � . . _... _..._... _ ..._ ... '� � �� � � _. , ,_. _ . , � . , __ _. _ , � _ , _ �� �,.. � �y . .. _� , �._ _ _ �'� �� � ,. ° w �. � � � � _--.._ __ _. . -° ; � ��� ; °�V""`,��� ' � G1 , �� a �� � , �,\ ����\� a�� :� ' �� LOBBY ��_ �,. '.� , �°� ' ��� BREWERY 109 4" DISPLAY :, � , ` ' iii ` 4„ 4,� FFCO , 2 °' � � 3„ ; ' H ' ' -- �.c 3" SAN UP (01 �P1.1) � � � ` �` . m....._. �RAiN ; ; 1Yz" VENT UP 01 /P1.1) ': ; � ,..: . . . - _.:.: _.. _ , ; ' � STOBAG� ._.._.._ �� �i _ _ .._ .. ......_ .. .... ...._........ .. .._ ..... . .. __.._. _ ................ __. ......._ .__.._ . _. _.._._ _..._.__ _.. _... ..... _... ..._ .. � __... _._ _.. _ . , . . , � � � 2 ; 1Y2' ; _ _ _ __ _ _ �. _ _ . _ _ � : _. _ _ _ _ _ __ _ _ __ � _ � s� _ _.� , . � ;' � ' . ._... ,. _ _ . � .., � � LOUNGE ' 1 10 ; r.., ; _. , : ; : � _. _ . __ L..:..._._.. ..._ _. _._. . . _ ... .._. _ _ _ _.. _ ....._......_ _ ;� ; � �.. �, ; ; ��r '. i i a ,; � _ _ __ _ _ __ __ �_____ _ .__ _ _. __.___.. _._._ ..._. _._ .. .._ , . .. . ____ _...._ _ _.. __.__._ . �_.... (E)FFCp ; TO EXISTING ' — — — �_ � � SANITARY , , SYSTEM BY � LANDL�RD i � t i � - - — �� - - � - - - __ - — - L I T I TE I T �1 RELOCATE EXISTING CL EANOUT TO RAISED F�OOR. 1 GENERAL: 1. PROVIDE AUTOMATIC WET PIPE SPRINKLER SYSTEM THROUGHOUT ASTE IN THIS VICINITY. FIELD VERIFY G U LESS OTHERWISE NOTED OR INDICATED. 2 CONNECT TO EXISTING SANITARY W ENTIRE BUILDIN N ❑ EXACT �OCATION AND MAKE NECESSARY CONNECTION AS REQUIRED. COVERAGE SHALL BE FOR LIGHT HAZARD OCCUPANCY. � ROUTE DRAIN LINE FROM FOOD SERVICE EQUIPMENT TO WASTE 2. FIRE SPRINK�ER CONTRACTOR SNALL ROUTE FIRE PROTECTION PIPING RECEPTACLE PER °'INDIRECT DRAIN" DETAIL. AS REQUIRED TO AVOID NEW/EXISTING PLUMBING, HVAC, AND ELECTRICAL. �4 CONNECT TO EXISTING DOMESTIC WATER LINE IN THIS VICINITY. FIELD VERIFY EXACT LOCATION AND MAKE NECESSARY CONNECTION AS O2 PROVIDE COVERAGE OF ORDINARY HAZARD OCCUPANCY FOR THIS AREA. REQUIRED. �ANDLORD TO PROVIDE APPROVED BACKFLOW PREVENTION DEVICE ON DOMESTIC WATER SERVICE PER LOCAL AND STATE �PROVIDE SHIELDS, TRAYS, AND OTHER PRQTECTION IN ACCORDANCE WITH AUTHORITIES AS REQUIRED. NFPA REQUIREMENTS FOR THIS AREA. ❑5 PROVIDE 6" BEVERAGE CONDUIT BELOW SLAB PER FO�D SERVICE 4OPROVIDE SPRINKLER PROTECTION IN STABRWAYS AS REQUIRED IN DRAWINGS AND PVC BEVERAGE CONDUIT" DEfAIL. ROUTE AROUND ACCORDANCE WITH NFPA 13 IF NOT PROVIDE BY LANDLORD. FOOTINGS AND PROVIDE PULL WIRE FOR VENDOR WITH REM4VABLE CAP. PROVIDE A FREEZE PROOF SPRINKLER SYSTEM IN THIS AREA. OPTIONS 6 REFER TO PARTIAL FLOOR PLAN 02 ON THIS SHEET FOR CONTINUATION. 5 ❑ ARE AN AUXILIARY DRY PIPE SYSTEM, DRY PIPE SPRINKLER HEADS, OR 7� PROVIDE 1Y4" HQT WATER �INE FOR BREWER, REFER TO DRAWINGS BY OTHER MEANS FOR A FREEZE PROOF SYSTEM AS ALLOWED BY NFPA 13. OTHER FOR CONTINUATION AND ALL DEVICE'S NEED FOR BREWER INC�UDING BUT NOT LIMITED TO FILTERS, RPZ°S OR BACKFLOW DEVICES. ❑8 PROVIDE 1Yz" COi.D WATER �INE FOR BREWER, REFER TO DRAWINGS BY OTHER FOR CONTINUATION AND ALL DEVICE'S NEED FOR BREWER INCLUDING BUT NOT LIMITED TO FILTERS, RPZ'S OR BACKFLOW DEVICES. Q REFER TO PARTIA� FLOOR PLAN 01 ON THIS SHEET FQR CONTINUATlON. 10 PROVIDE 8" BEVERAGE C4NDUIT BELOW SLAB PER FOQD SERVICE DRAWINGS AND "PVC BEVERAGE CONDUIT" DETAIL. ROUTE AROUND FOOTINGS AND PROVIDE PULL WIRE FOR VENDOR WITH REMOVABLE CAP. � ��z. . � � �,.:, �i�4�� �� _,... ��; � ;; e>. YZ" HWfCW UP TO NAND SINK (01 fP1.1) 3/4" HWjCW UP TO HOSE BIB (01/P1.1) __. .... _, 1 y2„ � _ ; � _. � _ : �, _ ii � _� ,._. i t _._._. _., ; � � _.. ; Y�" UP TO TRAP PRIMER (01 /P1.1) i.._._._..._.__i LOUNGE � ! !I i , � , _ °�:.._ .� 110 �� �-�,, -- --��� : � ; ' 1� :.._ . � . . _ .. .. .,�.- � x. . , , I. i ;, � � ._�.. . _ ... ,I {ii i : .;. ;, ; �; . ,: > , , , _.... __ _._ : ; � 7 .�L,,, . . ,_ .......v � . u b.. ..�-� ' :.d , w_ ... ._. . ._.. .. _: ................i . .: � ...�, ._.. 3 )9 :, , , �4 �... _ ; � � � {i , ,.. . . . & . _ � . ___� ;. ._�.__..� ' . , � 3 � 4 � _. �. � .. .... �� � a �Ya" ^ . 0 __ , _� ; ,,, ;,. - ___,i __ � — i -- � � � � >� �� ...� ��.� � �� .� ; � � �.. .�� ..�..� ., �n .�,' � � . �' �/� s" = 7'-0„ U � WCn OC Zw Z �� ti � � �� w � � • c�~is a o � ~ 4 � � _ — U Q o W � � w 2 �w�Q��C U °O ~ J �n � Q Nv�ia=.c*a� ���� �� ����: \ \ �\� \; O � _:... <........ `°'.t,:......... •!' ��� il� �����Y � � � � � � Q � J � � PRCJMENAL�E LEVEL PLIJ ["I BI N � PLAf�I DATE: 07. I 6.20 I 4 DRAWN BY: ESC �ILE: K:tFlixBrewhouse\Carmeil REVISIONS: � 4 10'_8" 21'-4'° COPYRIGHT 2013 JKR PARTNERS LLC ALL RiG!-iTS RESERVED ' ': � '���1� ___ ___ __ _. _ .,., __, ,` _ , _ l � ��� � �� �, � �, � � � . � � .� ��, � � � ; a� ; � a., � a �, ' , � � � � °� ` � �� � � � � �_ . . �a , �.� . .. . . . t . ' � � , .�. . � e . ,� .o _ � .... o . _ .. . _ d ..�, . ...s �. ...s :: J.. - ` \ �„ .. , � �. � , ' 'w.a �.,.' � �..,� . \. .,. `�.� e . _ � p �\ � , , I � . 1 / \ j,.\ r � \ �\ � \ . � ��� * � � � �`�. ., �, `,� l \ \ , ; . _..._� ; . _._.. __ __ _ . .. , `, ' ; i ' ' _ _. ;. ; ; ; _ _ __ �, _._. _. ._ _ . _, . .__. _. _ _._ _._.__ _ _ _. . _ _.,... _._ .. . _. _. \ �� ; , , ; _ ;.. ; . a. , ; � , �. i _._... _ _ _ ,, ,., . . � ' _.. _ _. _ . i ' �... : .�.. v 2 __..__. _...._ .._ \ �` • , __ _ _ _ _ _ ' _: _..__ ._ _ _.,.... _. .. _.... .. _.__. _ _ _.. . ... .. _.... _ __ _ __. .... _ . _..._.. . . _. .... _. _ _..... _._.. _... .. . .. .... _ _.. _.._. _ � . . . ,. ,.�. � .: �, ____ ___ _ _. __ � . __ . } , ! � 2" VENT DN (01/P1.0 : ', ' ' __._ _ I : ' 4 ' ��� , ; , ' O ; ; ; ; __: _... � .� I: '' ' ' ; ; ; ; , ' �� i �:: �� ������� � � � ; ; , .... , , ; , , , 1 , \ $ > ; ` � ;. , ; . ' ; ; ; ; � ,.. . .. _ . ,� � '� � a �' � ��"` ��;✓ �� i: . � !. � _ _ ; , ;.. _ �e S ��EWERY �� i ; , � ,D S \ .�� � � � � auoiTORiuM #i ; ; � � . ; , ��� � . zoi�Y 3>, SAN � DN � � 01 P 1 ���.0 � � � � � 1 ! ioi �� ; � , . ; � ;. , ; � ' � r _ , r_ � 3„ �� 1Y2" VENT FROM BELOW (01 /P1.0) �. a� ; � �� � 3 �. i� � ,_..: __. _ _.. _.. ..._ __ _ __ . .. _..._.... _..__. _ . ; _: .:.... ......... I: ; _ _ ; _ __ _ _ _ �-- s � � . , ;. ; � °" a� i _ ; _ " _._... , � : ; : ' _. _ _ _ _. _ _ _ __ _ _ __ ' _ _ _ _ _ _ � _ ,_ t_ _ _ __ _. __ 2 � ; , _ , � 1Yz � C�� � _ _ �_ _ p _ _ ,� � ; ; � , , _ �� � 3�� � ' _ , _ .. ; ; , �,.� � � 2 �, ! ; , � �:� � � " � + 3/a HW FROM BE�OW (02/P1.0) i i ;' ' ; � ; ; , ; ; ; _. ; ;; ' 1 4"VTR � ;a j�. F ,; ; , ; , ; , ; , ,...., r., 4 ! 3=° , 2 ' J +"�'"--�3j ; C FROM BE Q2 P1.0 _ �� � �� �:� � 4 w �ow ( I ) .�: H K �� �: ! ; , ; , ; ; ; ` " � ��. �a Y2 HW; FROM BELOW {02jP1.0) ; __... ;<_: _ _.: , . _. _ VEN N ( /P } 2 ; __, 4 T D 01 1.0 ��r: ; : ;: _. .... „ , _ __ _ _... � ' FROM BEL ( /P1 ) ; ; ; ____ _ • ; Y2 �; t�RAIN UNE BELOW MEZZANINE DECK �'� --- ; ; _ ; ; 3 , , 3 �y2„ , ... n � , , , ' ' �Y ; ; ;. � -., ;: -.K � ____ _._. ... .:.......... .. _. „ _ _ .... . . .. ......... _ ._.._ ...._ _...... _..._ _. . _. . _._ .. ... . ..._... . . _.. ...,., �"� ' _ F OM ELOW 02 P1.0 .. < . _ _. . _...__..._ _ . :.. .... ... .. _.. _... _... ... ... ., !_. .. _..._..._ _.. . . < < CW U P R B _ ., . ,... �, _..__ . ..... ........�......,._...__ ,�_ m..._�.___..�_ _�. _._,.,,.._...._____ __..,._.,_. � _ ....... :�. . ( ) � _ __...._.._.,.,_ __ . _,.. ,,,_. _. , ... _ _ V - ___ � . . ..__. . ..._.�:_. . _,,. _.. , _ __... _, � ,: , �. ,.: ., �:: ,_ _ ;...... .::::: _ , __ .. . , .. ; ; ; ; : ; ; , _ _ , , ; i; � ,;, ; � �: �I�� � � � , M 2 � � �° _ �� , ; ! ; ; �;� ; ;; ; ; __ ;' , ,. , �; 6 � �� _.._.. __..._._ _....._.. _.._. _ __. _ _.._ __ __..._. . i 2 ' _.. .. _ . _ _._. . ; ; I � � 1 Y � , ; _ _ __ ; ; ; _____ ___ _ _ __ ___ _ _ __ __ _ i ;, ; � ; _ _ _ _ _ __ _ __ _ __ _ __ I�i �l 3 ,> � , . i e I 3 � t ❑ ; � i : i .._ ....... ......._. � k � � : . � i : i : i . , . � � i i . . � i i ; : i ; � � ,� / Y� °--1 i ��, „ -__ � � � ' ; �� � � ; „ ; , ; , ; � , � � 3 ; � �; j� _ � - ; ' FFCO ' � t ' � � � ; , � � I�1 � ' (�-1 ! ; i r� � ; � V � I--I �..;� �--^--�' � ; ; J J _: ° ; __ __ _ __ � _.... ; ;: € ; _ �t C�t , ; ; , _. _ _._.w,�.�. m_.�: r�� A_�.;m._� _ ._� ..::: _.�; �.�� ...___.�..�� � �n.:��m .._.�..:�_� _. _....�, � _�.__�w:m _.�.,..�� ..._..� �� a ,; ' ; ' ; : ' � FERMENTATION m „ AUDITORIUM#2 1 ��,`�� ' DISPLAY EXISTING 2LB GAS PIPE ON ROOF YZ CW UP FROM , � i ;; �� BELOW (01 jP2.1) 3�4 CW DN FROM ABOVE {41 jP2.1) � YZ" NW FROM BELOW (01 jP2.1 } i a2 ,a; �_� , ��' zo2 7 2Y2,>�3,1 1 1) n ; �: 3 " � �: i ' � ' " CW DN FROM ABOVE 01 P2.1 ; ; Y , , ,:.. �. „ �: , HW FROM BELOW Q1 P2.1 : 2 .,. � � �^ � � ., �� � u � � i I ) � t � _, � __ e � �..., � . � z_. , t ! � ,. �,...,::� ; � 4 �: ,.. �. ! , .,� ?. ; �� � . . . . �: .. ,� , �;: �, � ; .�, �., �. � �. ` � �, Y2 a : � .. ; , „� �, �, � � :� .: _ . , , . ; r � .. .. :. _ v ... � �- -�.: � � � . _ a . ` ;. $ : �.— ; . —�. u ._� ...� _, a. ��.. m. �. ,: � _. ..F..a_ , , , , , . : ;.a_ ..,. � : ... _... � .... � ._..: ..:� ..:.. ^i- ,.. _ .,._ 3 '. :� :'p-_::.s.+?,,. ....,: n: .�._ . . .. . ;� ,} � �.: . � � � 1 .�.. Yz ; ; ; ; „; � �.m..... . _..._. ._._._... ���, ..' - �� ��. , :� > G ?: < � �:: -.:= „�:.:_:.: ",, ��f , ::: � � .. G _.... ,., ' ; � �:J '� �,�,=-„ ; ��� :` H � � �� WCO 3» 3>, O;: �.� 3>' 3" SAN DN (01.P2.0} ; ; �_ ; � _: ��L']- ;: _ : _ _. _ ; ; 3" V FROM BELOW (�1/P2.0) (— � � — — —L . 2�G � �.. �',.•-�L'J PROJECTION 2» 2' ��`� ' ; LEVEL O1 f P2.0 � YZ„ 1y2>, � 8 ���,� n , "—"1 7 I � ` ; � , 203 4 2 G �.:: _ � ', ; � �.,' g ; ,; _ __ 2,> 2,698 _ _ _ __ _ _ _ _ _ _ _ . _ _ _ � _ _ _ _- _ _ _ _ _ _G.�....r ,. �. '' - „ _ - �_ __ _ _ _ __ �__ _ �, _ _ _ � ) �: _ �� ;; e c� � � M a � � %I � � �13,��2�698)(01 /P2.1) ,-. � . � cv ,i �, � `_ 9 �. , � ; ' � I X I I\ I � I X I �n� (o �/�2.0} 10 v._. _ _ _ � _ 4"VTR 1 � � � � � �� ' , 4" VENT DN (03JP2.0) �� - ��: � � q.,, 4,> � 1 "(413) �� ���� 01fP2.0 _ _ _ � � , _ _. _ _ _ _ _ . __ _ � q. , � � � Y2"(63} 3/a"(,��o) Yz"(1�s) ' — � � 2#G 2#G _ ; ; _. _..��:��.__.�:�� _r. � ° 4� r' ,- 3la"(201),. Y2���149} ; , ; _ �::.� ��� ��� ��� � L�� N ; ; ; AUDITORIUM #3 ; ; ; � �� Z I' �� �n� ' � i 6 ; ; ; �o� �l �� , � ��� LBS TO OZ ( _ � , � ' cv REGULATOR � � I I � � � '; ; ; ; .r�_.. � ;_... ; , , �- J LBS TO OZ ' ; LBS TO OZ t�1 � � ; ; ! EGU(ATOR R u �6❑� ; I l���� REGULATQR_� �— I L..J ; MAU � � ��-�� � � � � I � � gs MAU 3 115 2 3 � � VJ � � � �� 149 CFH ; � ' '; ; ': ; ; -° � � 201 CFH , .� _::. ' � � _ .... . .. ......_.. ..,.. , . ..,.., _. __ ___.. . ', ; ; MAU __ _.... 71 3 _ _ .. , ,_. _ _ __ _.. ._ _ _.... _... ._ _ .__._. _ _ . _ . __ _. _._.__._. _ _ ... . . __. _._ ._ _ ...__ .... . ... .... . . __....__. _ ___ _ _ _ . , _. ___ _.. ____ _. . ____. ,. ___. :,.._. _ _ ,:_ .: � ; � _.___. _ _ _... _. . .. _.... _.. . �.:. . __ �r �.,.� ,_:.._. . ._._... _ __ , . ..._. . _.... . ......._.__.... ;: 3 _; � �- -: _. _ _ . ', ; � ;, ; ; 63 CFN _ _ ..._ _ ... . . '; �o� ; , ; _ __ _ _ _ __ ; ;. -::: _ ,_ _. . , _. _ _._.. _ ; ; � ; ; ' ` ; �� VJ ° : , ; ,.... _. __..... __. ' ' ' , , ' ; ; _ ; AU #8 FLIX MX DITORIUM ! ' _. . _.... 108 ; ; _. : : : ' 1 ; .__...�__�.__..�.�.,_m __._. ... ._...._._._ _._... .._..._.... . ._.._ _._ . .... . .._... .. . . __...._ . _...._ _ _ _ . . .... _....._._.. i ,. , ; _ �,� ; ; ' _. _ _.., ; ' ' �::' : : ' : � i i > ; �,; ' � :," __ _... . _ . ..._ ..... .. � � . .,..;., ..,...> . ;, : : . : I ; : :. ' : ! : ':' : ...__.. . . � ' AUDITORIUM #4 ; ' � � ' : :� .�... .: ..... ...... � j ' ; i ; ; _.... __.._ . _.... _ i� q . , : _.._._. . ... ? : � � 1 . , , , ; �� i �.. ._ r � �� k i �l � � e : ': ' , I —'' � i �, : ' i ': '; . ' :� e � ._._ .......... .......... ..._ ......... . ......... ..__.._ ...._..._...... .......... .._.._..._ ...__..._ i ' i ! : �i : i i i ; � i :: .... . . . i i i � ! i 1 i i : i ... ..... ..... ... � ; ' "': : : . ; 'i ._...: i.. : � . : . i ; � � ', ; ; ; ; ; , ; ,�, , � � , , � - � , � , __ _ _ _ _ _ : � : : : � : � : 4 ' °: : i: : 3 . � .: i, . '� , �� � . . , � ... . — . -.,. _ �.,... ,. � � , ;; , � ___ s � �� I , i ; ! ; o � � .,. _ �. _., . . . . ._... _ ___.. . .._.._. ._. ._. _.._.._..___. ...,,.._.._.... _ _.... ,_� _ ._. a :: . .I . . . �' , : ___ _...__._ _ _. _.__ _... _ ; , ; _.. _.. � _. � .. � i � �3 I i \\ ! ; ._ _ .... .,. __.. _ . .._ ..._:x . . :: . .. _ .._ _._... _... .... ..... . .... . . . ..... . ;... ... .... ; '_'___ _.e._ _ .__ _. __. ... . .._.... .....__ . ._._._. . . .._. .. ........ ..._ �.....,, . ., . ._ .... ..... ..... ... ._... . .. i. i _ __......_...... _. ......._............. ..... ..... __._ __ , .__.___...... ....__.._._.. ._... ..... _._..._...,.._ _. __..._._._ . .. .... ...._.. ..____... ..... ........_.. ..... __. ....__ , ..... ._.. ........... _....._.._..._ ._ ._.. ......... ______...._.. ....._........... . ..... ._...._.... .._.._ _... . ......_.....__ ..._.__._._... _.. ..____. __• __ _ ,.._.___.... .. .._ .____..... . : : i i : . . ___... .._____ . _..... _..�_......... ... ........ ..........._.................... .. .___ ...... _........ .... --_ , .,..._.. ' i i : : : ; ; �:::3:_-n :�: .._« . .R._.... �� � ... . . ..... ..... _. ... . : . . -...... .._.. ...,..: .. _ ....-.. ...., �..... ...,, � , �:::::: .:� � i : � "'+ ; v, ; i . � : . . : � . . ; : ; ....:_ `.. � i . , : . i : : . ; i : i ,; � , i . _.._ :� : �: : � : _i`. i . . : : . : : � : : . .. : : . i : . : ., v. ., . . . . . : . . . . . . . ; :: -;, � . . \, ` 4' i : : ' . .... ..._. _.... : t :, : ....... ...._. .... .... , ._. . ..... ........ ........ ._.. . . . ... � ' : i ; I i ....... _,. _.. ..... ..... .._. .. ....... . _....... .. _._... ..... .... � ' ; : ; j :, .... .. .... ..... � ..... . . . : : . ! i i ! _... £ .. _ ... _ �: .a.... ..... ; . . . , . . : � . . � .-:::: � ! � i i, � � i t� : � ; ; , i ; . . , I/ I � :........ . .... . ... . . : i ; ': . ' . i � ; ; k � : : . ' j , ...... .._.. .....' . , � � LJ i . ; i ; : i i i ........... .................. ........... ....._.._....._ _..... ._........ _............... . . ._............. ..- ..... i .. .............. i e i i � ' .... ... � i : .�... . ..... i . , t :.... .. �. . � : : — ' � . . .. ... ,.,m.. ....— ..,.. : � �.. — _.__ __ __... . ._ . ._._._. .__ _.._ _ __— . . ; _.; ! ; ; _ . ', AUDITORIUM #5 : , ', \` � . ��� , ios ; � :�. � , ' „ __ __ ', a �_ � � � z �l ��� _ _ _ � ` _ _ ,c .l ° � � � � 2 3 � ! _. �� i � ' i � � r � � � � i �- , �� `_ I ' � ` 1.�1 � , j t �� � '� _ � ` �� ; ; � � _.._... - .. _ _ \ ; _ _ _ _ __ _ _ . „ \. - __ - - _ — ` :� _ :.:, °: : � � " .._.. , _ _ �:�. � , _ _ d�� ,.. ... t .. . . v:..,, . ; _ ��l !�_ __ I �� �� � r� � �� ', �� , �� ;' t ' , . ,,. ,. ; , , _ _. , � '; i AUDITORIUM #6 AUDITORIUM #7 106 '°' L MBI NORTH /32 1 0 _ __ _ _ - ; - _ _, _ _. _ __ .. __ ___ _ ' _ ; P LAN . ,, _ _ _ _ ' _ _ _ � _ _ _ __ __ .. ,,; ,, _ _ _ � : . � �: �._ �....� :� , . � �. -�� , �, a, ; �., z ,, .�' �� �� � $' : ' ,_ � �� w . ,��.F €.�' .t� . ... .a? � �.� ` �` .� �,e� �, �a�� , �se ,� . . _ , : , ; . � \.. ` . ` 1 \� '\ �........_. � � ' �,,......._ �, ._.... n 07-14-14 09:09 Edwin.Counsman ' ' O1 GENERAL: 1. PROVIDE AUTOMATIC WET PIPE SPRINKLER SYSTEM TNROUGHOUT ENTIRE BUILDING, UNLESS OTHERWISE NOTED OR INDICATED. COVERAGE SHALL BE FOR LIGHT HAZARD OCCUPANCY. 2. FIRE SPRINKLER CONTRACTOR SHA�� ROUTE FIRE PR�TECTION PIPING AS REQUIRED TO AVOID NEW/EXISTING PLUMBING, HVAC, AND ELECTRICAL. 2�PROVIDE COVERAGE OF ORDINARY HAZARD OCCUPANCY FOR THIS AREA. �PROVIDE SHIE�DS, TRAYS, AND OTHER PROTECTION IN ACCORDANCE WITH NFPA REQUIREMENTS FOR THIS AREA. O4 PRUVIDE SPRINKLER PROTECTION IN STAIRWAYS AS REQUIRED IN ACCORDANCE WITH NFPA 13 IF NOT PROVIDE BY LANDLORD. �5 PROVIDE A FREEZE PROQF SPRINKLER SYSTEM IN THIS AREA. OPTIONS ARE AN AUXILIARY QRY PIPE SYSTEM, DRY PIPE SPRINKLER HEADS, OR flTHER MEANS FOR A FREEZE PROOF SYSTEM AS ALL.OWED BY NFPA 13. PLUMBING PLAN NOTES �1 PROVIDE SANITARY VENT THROUGH ROOF IN THIS VICINITY PER "VENT THRU ROOF (VTR)" DEfAIL. LOCATE VENT MINIMUM OF 15-0" AWAY FROM AIR INTAKES ON ROOF, UNLESS APPROVED BY ENGINEER PRIOR TO I N STALLATI O N. Q2 PROVIDE TRAP PRIMER IN THiS VICINIIY PER 'iRAP PRIMER" DETAIL. �3 HVAC MAU UNIT, REFER TO "MAKE-UP AIR UNIT C4NNECTION" DETAIL. FOR CONNECTION REQUIREMENT TO ROOFTOP EQUIPMENT IN THIS VICINITY. VERIFY GAS PRESSURE REGULATOR REQUIREMENT WITH EXISTING GAS PRESSURE AND GAS PRESSURE REQUIRED AT THE EQUIPMENT AND ADJUST REGUL4TOR AS REQUIRED. Q ROUTE GAS PIPE ON ROOF PER "ROOF BLOCKING PIPE SUPPORT" D EfAI L. Q RQUTE GAS PIPE THROUGH ROOF IN THIS VICINITY PER "ROOF PENETRATION" DETAI�. n�"'ST!"'G °nn�rno i inu-r -rn DC►AAIA1 nin runnirr ir,i DID=AI/� i V 1 1_/�1 IV I1VV1 I VI VIY11 I V IILIYI/"111Y� IVV lwi ll"11YVL IIY 1 11 IVV. ❑7 CONNECT TO EXISTING GAS PIPING IN THIS VICINIIY. FIELD VERIFY EXACT �OCATION AND MAKE NECESSARY CONNECTION AS REQUIRED. COORDINATE WITH THE LOCAL GAS COMPANY TO ADJUST EXISTING GAS METER AND PRESSURE REGU(ATOR AT THE DEDICATED MEfER LOCATION AS REQUIRED. GAS PIPING ON RQOF IS 2 �B AND BS SIZED ASSUMING A TOTAL PIPING �ENGTH QF 600' FROM THE LOCATIQN OF THE GAS METER TQ THE MOST REMOTE GAS EQUIPMENT CONNECTION. FIELD VERIFY EXACT LOCATIQN OF MEfER. S� �BS TO OZ PRESSURE REGULATOR IN THIS VICINIIY FOR A TOTA� CAPACITY OF 2,698 CFH AT 7" WC. GAS PIPING SYSTEM WAS SIZED ASSUMING A T4TAL PIPING LENGTH OF 100° FROM THE LOCATIQN OF THE GAS REGULATOR TQ THE MQST REMQTE GAS EQUIPMENT CQNNECTION. � RflUTE 4" INTAKE PlPE AND 4" EXHAUST PIPE FLUES FROM WATER HEATER THRU ROOF WITH A FACTORY CONGENTRIC VENT KIT IN THIS VICINIIY. INTAKE AND EXHAUST PIPE SHAL� BE EITHER A PLENUM RATED PIPE EQUIVALENT TO CORZAN OR PVC/CPVC WITH A FIRE BARRIER P�ENUM WRAP EQUIVALENT Tfl 3M #5A. VERIFY WITN PLUMBING OFFICIAL AS TO WHICH SYSTEM WOU�D BE ACCEPTABLE. ROUTE PIPING 1NITH P, MINIP�UM (�UNIBER OF ELB0INS AND PER THE MANUFACTURER INSTRUCTIONS. 10 MAINTAIN FIRE RATING OF WALL 1NHEN RQUTE INTAKE AND EXHAUST FLUES FROM WATER HEATERS. PIPE REDUCER FROM BRANCH PiPE SIZE TO UN1T CONNECTION SIZE AT UNIT CONNECTI4N GROUND JOINT PIPE UNION LB TO OZ REGULATOR GAS FIRED GAS SHUT-OFF C4CK MAKE-UP BRANCH PIPE, SEE AIR UNIT PLAN FOR SiZE BRANCH OFF TOP OF GAS PIPE MAIN EQUIP CURB DOUBLE BLOCK ROOF PIPE SUPPORT PER DETAIL 6° DIRT LEG 03 MAKE- P A�R N'T oNNECT�ON NOT TO SCALE .. � : ' :�! ' f i . s r i � r . ...� � ■ . � �.. �. ■ i � i �� .� R /�������� .' � ,` � . . � ,. .. — i� • .f t --- � � • � ; i •� :� .�� � � � ' �;; '.� �! �... �s�. � � � � r r � � -s• III� _— �� � � � � � � � ' � � � . � .. . ... � � ! ■ � � .. • � ' � � . � .. .. R ■ � � �. , � :� .;, � � . ■ ■ � ,. f � , , � ■ � .. �. � � ■ . �. . • �.... •, 1. �� �. � ' i i ' ' . i • • � THIS SHEET IS PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEEfS INCLUDING SPECIFICATIONS APPI.Y. THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING, THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS QF ALL ARCHITECTURA� AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN F4R REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE E�EMENTS. NO DESIGN RESPONSIBILITY IS ASSIJMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE REQUIREMENTS. a � . �pPN T. FRq r�i,� , • ' � `4'oir-�'G`�T���4��'/� , � � � = Na.11300274 � :•� „ . ; STATE OF %'� � �� � . � � Larson Binkley, Inc. T$16-997-9601 r�����'�•�DIA�;.P'�j���� 310 W 24th Street, Suite 200 F 816-997-9602 '''i,SS10NA 1E°�, 1$� � Kansas City, MO 64108 larsonbinkley.com Copyright 2014 r � W� � Zw z �(' ^ � a �i� w � � • v��i � � I- �C vi IN° � =°w U z � W � z w _ �S w � � Q � U oo�-��.rio�G �1�L Nc��cv� `� � � � � � � \ ( � Q � V � PROJE�iI�f� LE�/EL PLU I`� BI f�l G PLA�1 DRTE: 07.16.20 I 4 DRAWN BY: ESC FI�E: K:\FlixBrewhouselCarme!\ REVISIONS: � � O � � � o I n9mo99 � I IvAti t� v �r COPYRIGHT 2013 JKR PARTNERS LLC Ai.L RIGHTS RESERVED � ■ . ,; i r �1 VERIFY LOCATION OF EXISTING FLOOR CLEANOUT AND IF REQUIRED RELOCATED TO WITH THE WALL AND PROVIDE WALL CLEANOUT OR RELOCATED OUTSIDE OF WALL WITH FLOOR CLEANOUT. �2 REMOVE OR ABANDONED EXISTING SANITARY PIPING IN GROUND. �3 CONNECT TO EXISTING SANITARY WASTE IN THIS VICINITY. FIELD VERIFY EXACT LOCATION AND MAKE NECESSARY CONNECTION AS REQUIRED. Q4 ROUTE DRAIN LtNE FROM FOOD SERVICE EQUIPMENT TO WASTE RECEPTACLE PER °'INDIRECT DRAIN" DETAIL. ❑5 ROUTE DRAIN LINE FROM FOOD SERVICE EQUIPMENT TO WASTE RECEPTACLE PER "WALK—IN CONDENSATE DRAIN" DEfAIL. �6 ROUTE DRAIN LINE FROM FOOD SERVICE EQUIPMENT TO WASTE RECEPTACLE PER "ICE MACHINE CONNECTIONS" DEfAIL. ❑7 ROUTE DRAIN �INE FROM FOOD SERVICE EQUIPMENT TO WASTE RECEPTACLE PER "3 CQMPARTMENT SINK" DETAIL. Q ROUTE DRAIN LINE FROM FOOD SERVICE EQUIPMENT TO WASTE RECEPTACLE PER "PREP SINK" DETAIL. �9 CONNECT TO EXISTING GREASE WASTE IN THIS VICINITY. FIELD VERIFY EXACT LOCATION AND MAKE NECESSARY GONNECTION AS REQUIRED. 10 ROUTE 4" INTAKE PIPE AND 4" EXHAUST PIPE FLUES FRQM WATER HEATER THRU ROOF WITH A FACTORY CONCENTRIC VENT KIT IN THIS VICINIlY. INTAKE AND EXHAUST PIPE SHA�L BE EITHER A PLENUM RATED PIPE E UIVALENT TO Q CORZAN OR PVC CPVC WIT H A FIRE BARRIER PLENUM WRAP EQUIVALENT TO 3M #5A YERIFY WITH PLUMBING OFFICIAL AS TO WHICH SYSTEM WOULD BE ACCEPTABLE. ROUTE PIPING WITH A MINIMUM NUMBER OF ELBOWS AND PER THE MANUFACTURER INSTRUCTIONS. 4" VENT U P{01 /P 1.1) MEN'S TOILET ROOM � �� 113 � � � r �.:./ � ` , �, ` �. � A� 2,� '� �Yz t� - �y2>; \ �� g � �, � \ . �.c. � FFCO � � '� ,. A . 2" �: �i,_� i is � , .� , 2„ _ -. 2» ,� , 2» : 1Y2>� FFCO 4�� 4" � ____ : 01/P1.0 ,, 2„ _ ____ ; E „ ;; ; � ...... , ,, 0 2 , , �':. , 2 2>, � �Y„ �. ,,,. � 2 _ I ; ' : ; �. . , ; , �` , :; '.:. , �:: ; � 2 � ; ,' , A1 ( �A _ ..: _. � ' '� � _ _ �,J ; �./ O ( % I WOMEN'S 2�� TQILET ROOM � 4'� ,`` 4�, i ia 2>, __, �,� � _, _ . .4 . 01/P1.0 01/P1.0 ENLARGED RESTROO PLA 1/4°' = i'-o„ � � � , � 4„ I I � WCO ' � 4» � , � Z A1 � : a � t �� ( � A1 � . � O� � � , �D I , � :: � , � ��� —�—i ) \ 2» 2>, � �E�4�� \\ (� ;j t): � � `��/ ,�,,,. � � i WOMEN'S <. ��, � ' � I TQILET ROOM ��� I24 `:��\� (�). � ! ` � PRflMENApE \=./ ' � � I i 9 - � ��� ' ',. 'Z" � 2,� . i `�<Q�� . ta; � z _ � � -- A?„ 2,.� � � (E)F�'CO \ o�� � � �i-- -- 4;, I _ e��� FFCO i.. , 4. ..... ; 4 I �Y I _. ,, _.._: � y: � � 2 I C� , � (E)FFCO� I ; , : _.... _._... '� � yz � �Y2 a a : � I s � \ ;� ( � I ,, � _ f...i '� ' .. ' I I � £ c' . I � �� {E)4�, � I I � �E�4=� *� �tI) � �; � I 'I i� 1Y2 —�-I �._::_.. . I i O ' � z , wCO �� � � ' I � ' . � I _ �„ � � � i � � � ; I �' � i _p. � ..� �. _ � _.. � , _ __ _.. � I �2�� ; ._; , - _.._.___________._.____..: _; , � :......_. _._.__.._ I , , '_.__ __ . , � I i , �\ I � ,-:.. �..-.-.-.: :.-....: PROdUCTION & CONTROL ROOM 127 OFFICE a 2s �— {E)4" �.c. izz � ' wco ,�; __ _ , � , 2,� _ ,.. _ ,,, _ ; ' _....:: ..,.� _.....�. � � ",,, ,.r:' .> � , � 3 3 � � , � _... , 3 � � � - ' ` N/C� , � , k: '. . � 2 _ Y ,o �. WCO. : O � WGO ; � , 3 _ 2 4_'64 � 2„ O . ' : 4 �--�-G� � 4 4 ' ( L 95 3 , � , 296 293 �� � 3, O e.. �� � O 3•. 2,. e�. ..,,> . , GW --��� � : ���� � ��GW �+�--�-+c � � ;.. ; � � , , � ; , , , 3 .. . __ ; 2 � r4_ �6 �; y 292 4 ,'� �u V �g7� <: ; .. _ _ , {� » V � , 3 ;, 3 , , s � � L ��' 27 ; u : ; �"'"� ` : O ,:. � 2„ ; , � t ____. � 3 261 __ ; 3 � BAR ; `i " ( ; 27{ � ...., ' ; ;; , ; ; ; � i ioA ' F �Yz , ' : .2 �� :; �:.__ .... a �'r. ' �: ; ...,, �� � � � _.. 259 � : � � ; 2.. >, _._... _.. .. . ; , f- z ; � � I .—, 3 4 58 � , � ��j � ; �e , _ . _... �. ,��.� , ___ . , .. ,: � �,� _.: 4 56 c, x� W—(� lJ c �3 Q 4 4 4 54 �>, 2°, 84 Q 283 � �. 3 3" 3„ 1Y2 , FFC r�t. •,�.�.,.. _. _ ._ . __.,__... _ ... _.... ._. . ;�� �> V� � � ^ �- 2 � .., _ _. �. � ....... . . __..._ _._._ , , , _ , � z , _ � ' ' � ,..� #� , � 2� r � ���" 4., 3 ��� p '� � � 1Y2 ���`���`�� �� , , , t�� ,� . 3 \ i § ' �-� $.��0 i: � ��. . � 2 � �} - i #f : . '�; ._:.` .. f ...,�,. � . a ... _ � � �, , ; , , f � , � ?; �_ _ ., tt�,: t �� { � � :. ; ,. � _ � .� , ,...--' '' _. ; ; , ; � Y.. . , . -. :., -. -;_. � �__... . _._ _.._ 237 _ _ 238 � � � e E t $ j i� f ` I _ . i i £ . ,� :� 1 , = 4 ,� � � ,> � 4 ; � • � � � ( �� �� i � �� �- 3� � �� �� 3„ � - �� � � :� ....� � ..........: . .. .... ..... .... _. ....._. _ 3,> _... ; � ; � _ . �_ _ .� - �- � 3" V UP (01�P1 1) ' �: � __ .. � , __.. 2" ; _ _ _ _ ! _._�...�� %. _: � 01 /P 1 1 : . ,. � _ _ _._ ._ . ___ 221 � � 221 � � ; 4 4 4„ � � \ �" _ _ _. ,, � 3" 3„ �. , -ti— _ : ,.. �, ; � _ �. a � � 3 � �� > � � ��- ; ,,..,; : ' ' , : , � 1E __ „ . .. �, i � __ _ ...,. � � ! . :.. , s � . ; : I �. i � , > . _ , __ ,� � (E)4,a o�/��.o �-- ---- --sA�------- — --i O1 /P�.Q PRODUCTIQN & / CQNTROLROOM � � `� 3» Z � 1= �, ;k' tI� � _ , � ,, Q � - ` �, I � � ' 0 /P2.0 I � � FAMIIY 2" , I � ; . _.... � � TOILET � � �,:../ � � �,�< � ���� � I � 123 �„ ' � � �. ;� � 4„ WCo � , '�...,�.. ;: ; FFCO I � 2>, ;�� 1Y2 � � � a� � � 9 � 4„ ; Zvv I � � ,. � � . � WGO i £z.. �� �„ � � O � �,,._ 2„ f �, �; _ ; _ 2.� , � ' _ i ___ _ 2„ ; MEN'S � I I 2" TOILET ROOM � � I 121 ��� I � �. 2„ I ��, � � � M,. _ �— _,.... Q I y � 1;:;./ < ) ; II � 2" �J�� �, ���4 �''`) � _ 2" � I I _ �B ,.: <�: ' � � >, ', , 2 � I I , �� ; , � B � 49� 2" ; c��. �� ' ,. � � 2 �E)4» � {E)4" x x� � � � �-- �x� x �=�� - , ��� �— - - —`� -- --- sAN — I - � — -- � 3C- �FFCO �' � ���� t b 3 2 �� `.,� � � � � � 2„ �,.:- � 2» A1 � � 4�> � WC0 I � (E)FFCO ', ; �. E 4-„ .___. ......... �! I� � � I .___. ' _ , � � 01/P1.0 E L �/4" _ �'-o" 1120137302PXX.dwq 07-14-14 09:09 Edwin.Counsman �— { E � ,�„ S.AN -- — *: � ���� ; ;� � 01 jP 1.0 � z� ��„ �Y2» OFFICE 128 �- (E)4,> GW----- r -�-.3 � � ; �k 4 w.: - , _. _4>, Vff �� ._, �� � � ^� $`�' ,�° � I _ �?� 134 � � 0 � ,. _. � � 3>, 3>, GW FFCO ,� ili I �� i � i� �� . .�� i ; o 1yz„ ti.J 17 � � � 2„ — 3" � _ - i ; � i �__._ �, LOUNGE ivo � �.. ,: , \ � � '.. `, l : ��_ _ �_ ._.�� � __ �, ; � � i1Q i` ' �: � ' � : ; ' ; � ; , _ ;. ,. ,. C� �� ��; � s � e �� ' �E i � �� 5 i 55 ` 3 � 3 � ! ; j4„ 3" SAN UP {01 /P 1.1) - ;;_ ' . � � � � � �.:J �� 2 �� �) ^ � � 4 �� £ \ �� �__,,,, .�, _�.....w ; ; � ; � 2 ;� __. — �—x _ _. X �\ \\ �., � � . 2���' 3�� 5 7 53 a � 10 TYP {01 jP 1.1) `'�, � 1NC0 : , � � ; _ . . w:: . 3 �: �� �, � � �. z < _ � � � �; 3,,, .� �. _ _ �, ; � ;,, �� � „ � _ , , ,, ,-,,��1Y2 � � .- \ � `� ' ° \;, � ; . ,. �' ` ' ,�`���� > a . . . \\\ � �.,,_.� r � _... _, _��.,� „ . . ._�.� , _.� �1 , x a .._ _ , F �'.�'���� __ �: � ,— 2„ � fnl � � �: J 4 4 2 13 i2 4 8 ,._ -�. . � : _ , ' t� _ . � � � � : � � a� �.`: � _ _ _.... _ WCO _.. � _ _ � _ � ` _ � 3 .,.,:. ;� _. _. � �, _ __e �.__,.,_ __. . ___. ,� � 2» � 2„ _ _ _ � _ �;Y -' _ . _ _ 2„ � ' , - �, � : � i ���, � ; .� : ._ ..... ......... .:� : BREWERY DISPLAY ACCESS sTOz _ . � ..�. THIS SHEET IS PART OF THE CONSTRUCTION DOCUMENTS. OTHER SHEEI'S INCLUDING SPECIFICATIONS APPLY. THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFI' LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO GONSTRUCTION AND THE ENGINEER ASSUMES NO LIABI�ITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE REQUIREMENTS. � � \ I �S�N � l.arson 8inkley, Inc. T 816-997-9601 310 W 20th Street, Suite 200 F 816-997-9602 Kansas City, MO 64108 larsonbinkley.com Copyright 2014 � tj T. FA .,°`' ` ��`.••.o....;Q/�'s ```P�¢,•�\ST �R•.�.f-',,'i � .•Q� �Q .� � _ � ' No, 11300274 � = = = . '; STATE OF � ' = �-�. `w� -� ��,: .r o� �,N NP.;\� �`` r'�!'sj�s'��oiul� i ��i� 1e � +ntt a� � � r L �i W� � zz � (,7 � � O �,�/ � w � 1..{� � �• � � o H 4 vi � � z �MW U J p J M Z � Qapai� = j c� � � oo H � °� n- � N � _ � �G _ S/� � N —, ���V������� ���� \��� �� � , . .. , ��C �/Y ����E" W W '`� � — � Z � W J W � � � Q U � � � DATE: 07. I 6.20 I 4 DRAWN BY: ESC FILE: K:\FlixBrewhouselCarmel\ ����S�a�s: Z � O _ � o A �-oaa pi��n �r a COPYRIGHT 2013 JKR PARTNERS LLC ALL RIGHTS RESERVED � . . t ❑1 PROVIDE WATER HEATER IN THIS VICINITY PER "BREWERY WATER HEATER" D ETAI L. �2 PROVIDE EXPANSION TANK IN THIS VICINITY PER "SMALL EXPANSION TANK" DETAIL. �3 PROVIDE RECIRCULATION PUMP IN THIS VICINITY PER '°BREWERY WATER HEATER" DETAIL. �4 PROVIDE WATER HEATER IN THIS VICINITY PER "RESTROOM WATER HEATER" DETAIL. ❑5 PROVIDE TRAP PRIMER IN THIS VICINITY PER "TRAP PRIMER" DETAIL. Q6 ROUTE GAS LINE TO KITCHEN EQUIPMENT IN THIS VICINITY PER '°COOKING APPLIANCE GAS°' DETAIL. Q7 PROVIDE WATER HEATER IN THIS VICINITY PER "KITCHEN WATER NEATERS" D ETAI L. ❑$ PROVIDE EXPANSION TANK IN THIS VIGINITY PER "(_ARGE EXPANSION TANK" DETAIL. � PROVIDE RECIRCULATIflN PUMP IN THIS VICINITY PER "KITCHEN WATER HEATERS" DEfAIL. 10 ROUTE CO�D WATER LINE DOWN TO FSEC EQUIPMENT AND PROVIDE WATTS #L7 BACKFLOW DEVICE PRIOR TO THE FILTERS/EQUIPMENT. FILTER TO BE SUPPLIED BY FSEC OR VENDOR OF EQUIPMENT. ROUTE FILTER WATER TO THE EQUIPMENT AS REQUIRED. 11 ROUTE COLD WATER LINE DOWN TO WATER FILTER SUPPLIED BY THE FSEC AND PROVIDE WATTS #L7 BACKF�OW DEVICE PRIQR TO THE FILTERS. ROUTE �ILTER WATER TO ICE MAKER PER "ICE MACHINE CONNECTIONS° DETAIL. 12 ROUTE COLD WATER LINE DOWN TO FSEC EQUIPMENT PER "GARBAGE DISPOSER" DETAIL. 13 COORDINATE WITH THE GENERAL CQNTRACTOR AND THE VENDOR FflR A�� REQUIREMENTS FOR THE CO2 AND NO2 SYSTEMS AND THE "NITR� DRAUGHT MAX" NITROGEN GENERATOR. THESE ITEMS SHALL BE PROVIDED BY THE SYSTEMS VENDOR. COORDINATE WITH THE GENERAL CONTRACTOR TO DETERMINE RESPONSIBILITY FQR EQUIPMENT AND PIPING SYSTEMS INSTALLATION. REFER TO THE FflOD SERVICE DRAWINGS FOR ADDITIONAL INFORMATION. 14 PROVIDE WATER SQFTENER IN THIS VICINITY PER "WATER SOFfENER" D EfAi L. 15 PROVIDE MASTER GAS SOLENOID AND SWITCH AS REQUIRED BY CODE. u Rvu i c nv"r' �i v ovv� i�-�'c r"-�ivii Ti ri�iv i v VIJfIYV%iJriGR r"�..`'� Rc�uiR�v. WOMEN'S TOILET ROOM 120 �3 0, _ a�/�1.0 BREWERY DISPLAY 201 A 1 � ,....' ,� � _ . � y4„ _� � �.,. A1 ,,,, : : �- :J \ �� :� 1�z,> �`. � yn—� � : 2 \ .�• _ F ; ,� �, � \ ..^- /, ��`�� � ,- M , ,. � �j(� � � � �- �.,1 , "� � 2 �, � G. ��(A) � � �� ._� _- � �- ...... _ �2„ ._...:., 3/4 2 » � 2" 2,> I : � C � � :� \ : �.: ., . 2�� K � y2�FiW/3/4��CW ; ;, I � G+ � . � � C � � �, `-y�„ HW�CW .� Q � A1 '���y �� 2 y2,. �J _ � � � 3�4„ ��I \�\* �., �: , ��_, Y2"-, MEN'S TOILET ROOM 113 K K C C � .. .. ' ��, . . .._. 2>, � - 2 �, � ; � y2 �,�' 1 Y2 ' I I—`�' Y2 »- , � � ;. ; A 1 ,;'J `:/ . 4 Y2 , �--y2" ��, _ 3/�_�.-- P 4 J.c. �-� P 1 2 �---- -� i i s ; �'�`' ���„ ,, ,� y �, 2 �;' WOMEN°S TOILET ROOM 114 _ __ _ 2., .,,, .. 01 /P 1.0 �__ _...._. C O2» 2» , . - � ' ' • i ' � � .� 'e y „ e � ? 2 �� - ... ..:: _;__ ... _ � �>, � _._,_ .. .. , L_—.._._._.... ..... 2 aa \\ I \� '�� � _ .. __ , y„ ,: /` 2 � 'j� � r� , � � 4i, �� I \\. y2" HW/CW i C , �. ; ' 2„ K �� . ~� . 1 �, o. MEN'S TOILET ROOM 121 �120137302PXX.dwa 07-14-14 09:09 Edwin.Counsman 2 � B1 2�� � �- „� ; � 2>a Q ,,; ,� ', V� ; 2» �i'�i , y2» �\ Y�„ �„ � � / B �. D �, � - 2" 1Y�„ A 1 �- �',� ;� ; , 1Y4,� A1 �...._ � , � 01 /P1.0 -,.. 01/P1.0 , ' , �� _ ��• � ' � �■ � �\ � 1'° HW/CW IN LOW WALL�„', . „ , ,,., ,.,,., ,., , ,.,.. ..,., , . „ . ,,.. ,..,.. ,.. , ...., ,..., . %4 ` Y2 � ' ' � �, � . , � j.�,• r � � i � . � , . �� i i • * • � i THIS SHEEf IS PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY. THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO 8E USED AS A SHOP DRAWING; THEREFORE, INCLUDE AI.L MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL. USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCNITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE REQUIREMENTS. ' ) , � ' � `�``��PN T, Fqq�;''. � `.4�.Q���ST�,q�,.,�.s.,,f i O� � • ° _ : .. ' No.11300274 = � �.' STATEOF ; •� �-o=. : Q` Larson Binkley, Inc. T 816-997-9601 `� �.� , :`kj�` 31Q W 20th Street, Suite 2Q0 F 816-997-9602 '�Q°�'F*•N41AN.P''�j1��' Kansas City, MO 64108 larsonbinkley.com ''°i'SS/ONAi �� ` t c� Copyright 2014 C '�`' . � • �` � • , � . . . � . . - . . � • . .. . � � • � .. . . � s � � � � � � . \ � . ' � •� • �' • � � . . ;� . . � �' ♦ � ♦ DRTE: 07. I b.20 I 4 DRAWN BY: ESC Fi�E: K:\Fiix�rewhouse\Carmell REVISIONS: Z `� O� �o �� ai o°_s„ z i°-4t� COPYRIGHT 2013 JKR PARTNERS LlC ALL RIGHTS RESERVED �, . . , )120137 STUB ELBOWS 6" ABOVE FLOOR AT LOCATIONS SHOWN ON PLAN AND PROVIDE REMOVABLE CAP SEAL TO CABINEf WITH SBLICONE SEAL FLOOR PENETRATION WITH FLEXIBLE, FIREPROOF AND WATERPROOF MATERIA� TO COMPENSATE FOR PIPE EXPANSION (TYPICAL) FLOOR SLAB VAPOR BARRIER LENGTH AS REQUIRED PROVIDE PVC BEVERAGE CONDUIT AND FITfINGS EQUAL TO BEVSTREAM SYSTEM (WWW.BEVSTREAM.COM). USE MINIMUM QUANTIIY OF FITTINGS WITH LONG SWEEP ELBOWS AT BOTH ENDS WITH A MINIMUM RADIUS OF 30" ON 6" OR SMALLER AND 48" ON 8" OR LARGER. AVOID ELBOWS iN HORIZONTA� RUN IF AT AL� POSSIBLE. GENERAL CONTRACTOR SHALL SEAL ENDS OF CONDUIT WITH FOAM A�CER BEVERAGE LINES ARE INSTALL IN CONDUIT. COORDINATE WITH F04D SERVICE DRAWING FOR EXACi SIZE AND LOCATION OF CONDUIT. CUT CONCRETE FLOOR SLAB, BACKFILL, REPAIR VAPOR BARRIER AND PATCH SI.AB PER ARCHITECT'S REQUIREMENTS. NOT TO SCALE FOUR COMPARTMENT SINK WITH LEVER WASTES. CLEANOUTS �N ENDS OF PIPE - FLOOR ..- � �� __� 1Y2„ VENT I N WALL ' �CLEANOUTS � IN ENDS v OF PIPE C LEAN 0 UT—�. �-3" 3 "-`,. ARRANGEMENT SHQWN IS SCHEMATIC. ADJUST T4 SUIT FIELD CONDITIONS QR MEET LQGAL CODE REQIJiREMENTS. NUB�ESS CAST IRON F'IPE, FITI-INGS AND CONNECTORS ALL AROUND SINK AND TRAP. NOT TO SCALE COLD WATER SUPPLY / � TO WATER HEATER �� AIR CHARGING VALVE. FILL TANK WITH AIR PRESSURE TO MATCH WATER PRESSURE, THEN OPEN VALVE 1 BUTYL DIAPHRAGM —�_ -� �t- M4' •• WE�DED STEEL EXPANSION TANK WITH PO�YPRQPYLENE LINING .. � r � � �-. PIPING ARRANGEMENT SHOWN IS SCHEMRIIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTA�LATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTAL�ED. PROVIDE SEISMIC STRAP OR BRACING WHERE REQUIRED. EXPANSION TANK TO BE FURNISHED AND INSTALLED IF BACKFLOW PREVENTION DEVICE IS REQUIRED ON DOMESTIC WATER SUPPLY BY LOCAL CODES AND AUTHORITIES. EXPANSION TANK INSTALLATION SHAL� OCCUR ONLY WFiEN THERE IS A BACKF�OW PREVENTIt}N DEVICE INSTALLED WITHIN THE TENANT SPACE WATER SYSTEM OR BUII.DING WATER SYSTEM. 13 LARGE EX ANS'ON ANK NOT TO SCALE HOT WATER TO COLD WATER SUPP�Y FIXTURES AS �TO WATER HEATER SHOWN ON PLANS ----.,,,'� TO EXPANSION TANK HEAT TRAP 18" MIN. j 1F REQUIRED, SEE DETAI� CENTER TO CENTER-� 1 � PROVIDE A 210° F TEMPERATURE SHUT-OFF VALVES (TYP) = AND 15Q PSI PRESSURE RELIEF � VALVE WITH TEST �EVER 51ZED PIPE UNlONS, WITH AGAfCGA TEMPERATURE (DIELECTRIC REQUIRED STEAM RATING 10� QVER FOR DISSIMILAR METALS) HEATER iNPUT ELECTRIC WATER HEATER. HARD COPPER RELIEF REFER TO SPECIFICATIQNS DISCHARGE LINE. FULL SIZE AND P�UMBING FIXTURE �F VA�VE OUTIET TO ENQ SCHEDU�E OVER Mfl8 BASIN WITH A TWO PIPE AIR GAP PROVIDE WATER- TIGHT DRAIN VALVE GALVANIZED SHEET METAL SET WATER HEATER ON PIATFORM PAN 2°' QEEP WITH 1" DRAIN PIPE TO RECEPTACLE (PLATFORM IS BY GC) PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIE�D CONDITIONS. REFER TO FLOOR PLAN FOR PIPE SIZES. SET WATER HEATER THERMOSTAT AT 120' F. PROVIDE SEISMIC STRAP OR BRACING AND FLEXIBLE CONNECTORS TO WATER CQNNECTIONS IFfAS REQUIRED BY L�CAL AUTHORITIES. E NOT TO SCALE 07-14-14 09:09 Edwin.Counsman NOT OR ON HORIZONTAL BRANCH LINE LESS THAN COLD 20 FEEf LONG, PLACE ONE WITHIN SIX WATER FEET OF THE LAST FIXTURE SERVED SUPPLY ON BRANCH LINE GREATER THAN 20 �� RRRESTER FEET LONG, PLACE ANOTHER ARRESTER IN THE MIDDLE, EACH IS SIZED FOR WITHIN SIX HALF THE FIXTURE UNITS FEET OF FI XTU R E SERVED SINGLE FIXTURE MULTIPLE FIXTURES PDI FIXTURE SIZE UNIT LOAD AA 1-3 A 4-11 B 12-32 C 33-60 D 61-113 E 114-154 F 155-330 FIXTURE UNIT TABULATION FIXTURE COLD HOT WATER CLOSET {VALVE) 10 - URINAL (VA�YE) 5 - LAVATORY / HAND SINK 1.5 1.5 SINK 2 2 MOP BASIN 3 3 DRINKING FOUNTAIN Q.5 - WALL HYDRANT 3 3 PC TO PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PIST4N AND 0-RING CONSTRUCTIQN, HAVING PDI #WH-201, ASSE #1010 OR ANSI #A112.26.1M CERTIFICATION. SIZE AND INSTALL PER PDI #WH-201 STANDARD OR MANUFACTURER'S INSTRUCTION. THE TABLES AB4VE ARE BASED ON THE SIOUX CHIEF PRODUCT LINE. IF PRESSURE IS IN EXCESS OF 65 PSIG THEN UPSIZE THE ARRESTER BY flNE {EXAMPLE: AN °A' ARRESTER WQULD BECOME A'B' ARRESTER.) NOT TO SCALE THREE COMPARTMENT SINK CLEANOUTS IN ENDS 1Y2" VENT IN WA�L T i - --��- . � # f ' E�j #i' � i . .. ,, . . � . ,.., * . a� � s � '•' •' • . •i - l� ' i�. �.i. 1... � l.... ..�i .��ii 1�. •1:.. • . � . , • # • , • • • • COLD WATER SUPPI'" TO WATER HEATER PIPE UNION: DIELECTRIC IF QISSIMI�P,R METALS PIPE HANGER NEXT TO PIPE TEE =LDED STEEL CPANSION TANK WITH JLYPROPYLENE LINING BUTYL DIAPNRAGM _` ,,., °�__��• AIR CHARGING VALVE FILL TANK WITH AIR PRESSURE TO MATCH WATER PRESSURE, THEN OPEN VA�VE PIPING ARRANGEMENT SHOWN IS SGHEMATIC. ADJUST TO SUIT FiEI.D CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FQLLOW MANUFACTURER°S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTAL�ED. EXPANSION TANK INSTA�LATION SHALL OCCUR ONLY WHEN THERE IS A BACKFLOW PREVENTION DEVICE INSTALLED WITHIN THE TENANT SPACE WATER SYSTEM OR BUILDING WATER SYSTEM. 14 SMALL EXPANSI N TANK NOT TO SCALE '�• r� . PROVIDE SHUTOFF VALVE ON ROUGH-IN � SUPPLYDUPAIN R PARTITION WHERE DUAL CHECK VALVE, WAl-fS #L7 ' SHOWN ON PLAN INSTALL WATER FILTER PER MANUFACTURER'S INSTRUCTIONS IF � ADAPTER AND SIX FURNISHED WITH ICE MACHINE - FOOT LONG, 3i�='� MAKE ACCESSIBLE REINFORCED FOOD ICE MAKER GRADE PLASTIC TUBING TO CUBER WATER INLET. USE HOSE CLAMPS AS CONNECT TO REQUIRED CUBER AND ICE BIN DRAIN OUTLETS AS INDIRECT DRAIN REQUIRED BCE BIN � OPEN TO ' UPP�ERPENDE AT DO NQT INSTA�L VALVES IN CEILING SPACE FLOOR �W TD �� PROVIDE AIR GAP OF TWICE PIPE DIAMETER PROVIDE TRENCH DRAIN AT FRONT EDGE OF ICE MACHINE, WHERE ACCESSIBLE FOR CLEANING - NOT UI�DER ANY EQUiPMENT PROVIDE COLD WATER ROUGH-IN AT TOP OF ICE MACHINE. ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO SUIT CONDITIQNS. VERIFY CONNECTIONS WITH MANUFACTURER. I NOT TO SCALE �l�I*ZK�PIJ�1:��1����9n1:1 coi 2 3" FLQQR SINK FLQOR MAI NTAi N AI R GAP TWICE PIPE DIAMETER �,� ARRANGEt�ENT SHOWN 15 SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS OR MEET �OCAL CODE REQUIREMENTS. UTILIZE HUBLESS CAST IRON PIPE, FITfINGS AND CONNECTORS FOR SINK CONNECTIQNS NflT TO SCALE 2" HARD WATER BYPASS VALVE - INLET VALVE TYPICAL PIPE SUPPQRT EXHAUST HOC?D ANCH�RED TO WALL MANUAL GAS VA�VE � GAS SHUT-OFF VALVE, GAS PIPE HEAQER ALONG WA�L BEHIND PROVIDED BY HflOD COOKING EQUIPMENT, APPROXIMATELY ca VEf�DOR, INSTALLED BY 12" ABQVE FLOQR, WITH SCREWED PC INTERCONNECT TO FITfINGS, SIZE AS SNQWN QN PLANS. HOOD FiRE SUPPRESSION PRflVIDE QUANTITY AND SIZE OF SYSTEM BY FPC CONNECTIONS AS REQUIRED FOR FLEXIBLE APPLIANCE EQUIPMENT BEII�G SERVE� CONNECTOR FURNISHED BY FSEC AND INSTA�LED MANUA� GAS BY PLUMBING CONTRACTOR VALVE (TYP) � `- 1YPICAL 6°' DIRT LEG FLOOR � " TO 6" ABOVE FLOOR ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT ACTUAL CONDITIONS. ATTACH RISER AND HEADER TO WALL WITH 1" CLEARANCE BEHIND PIPE. MAKE FINAL CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURER. PROVIDE WELDED FITTINGS/JOINTS IN ANY GONCEALED, UNSLEEVED LOCATION KIN LIAN IP NOT TO SCALE : a►. 2" SOFI� WATER TQ WATER HEATERS GHECK VALVE OUT�ET VALVE : : � �:,��� " : �. r- s � • i� .. i '" ' : - . � . . ... COVER VA�VE BODIES WITH INSULATION, BUT NOT UNIONS TAPE JOINTS� OF FIBERGLASS INSULATION MITER THE INSUlATION AT TEES AND PROVIDE A ONE FOOT ELBOWS SO THAT THERE ARE NO GAPS LENGTH OF AT JOINTS. PROVIDE ONE-PIECE NON-COMPRESSIBLE PRE-MOULDED PVC FIITING COVERS INSULATION AT HANGERS FOR ALL PIPE 2" AND LARGER PROVIDE INSULATION ON DOMESTIC REFER TO OTHER DETAI�S HOT/COLD WATER PIPES, STORM WATER FOR TREATMENT OF PIPES, AND CONDENSATE DRAIN PIPING INSULATION AT PENETRATI4N IN WALLS AND CHASES OF WALLS AND FIREWALLS FLOOR PROVIDE FIBERGLASS INSULATION WITH ALL-SERVICE JACKET WITH VAPOR BARRIER ON ALL COLD/HOT WATER PIPING AND CONDENSATE DRAIN PIPE. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION. INSTALL A�L iTEMS PER SPECIFICATIONS AND MANUFACTURERS INSTRUCTIONS. MAINTAIN VAPOR BARRIER ON COLD PIPING BY MEANS OF SEAtANT AND TAPE. FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES SHALL NOT EXCEED 25J50. SEAL EXPOSED ENDS OF FIBERG�ASS INSULATI�N WITH ADHESIVE MASTIC. NOT TO SCALE ..� r .� i ,r c.i .� ,. �. �� � . ���. �. � �. . �.�� � I .: •• •�. • '. � s. i-'• � •` i •i' "• � :'�' , .� ��� :., , . •�- •. � -.� �7� ., � � •' � , ' � • • � � s � : y . * � � - '• '• •' � : � • •�. � �' • � • � # ! i- i� - .! t ., *. * .. � � � , � t < i' t • ��_ ■ ��� � < a � � � � � � � • a a �:.. r � ',.. .. � � '.. � � � . ..� ��, ;. ,��� -. � i •.. # � ♦ l � s � * .... y ��.f .�i ! ! ! . �� �. � . # . � . , i � ' + � • • RECIRCULATION PUMP ON TIME FULL PORT BALL SHUT-OFF VALVES (TYP) CLOCK, COORDINATE WITH STRAINER OWNER FOR ON/OFF TIMES STRAP-ON AQUASTAT SET 5 DEGREES LOW�R THAN HEATER TEMPERATURE (135°) CHECK VALVE (TYP) I - �4-' � HOT WATER TQ FIXTURES ���� �y2» AS SHOWN ON PLANS PIPE UNIONS, DIELECTRIC COLD WATER 3�4 1Y4 � REQUIRED FOR DISSIMIIAR SUPPLY METALS (TYP) EXPANSION — �__�..-6" LONG DIRT LEG (TYP) TAN K �, INTAKE � GAS SHUT OFF COCK (TYP) , GROUND JOINT UNION (TYP) �Y2» WATER HEATER PROVIDE A 210° F TEMPERATURE AND EXHAUSTf INTAKE (T(p� 150 PSI PRESSURE RELIEF VALVE WITH PIPES, REFER TO TEST LEVER SIZED WITH AGA jCGA PL.ANS FOR TEMPERATURE STEAM RATING 10� OVER CONTiNUATION HEATER INPUT {TYP) EXHAUST HARD CQPPER RELIEF DISCHARGE ��3 �INE, FUI.L SIZE OF VA�VE OUTLET TO END OVER WASTE RECEPTACLE WITH FfNISHE� FLOOR TWO PIPE AIR GAP {TYP) SEf WATER HEATER ON MASONRY UNITS (TYP) REFER TO SPECIFICATIONS AND PLUMBING FIXTURE SCHEDULE FOR WATER HEATER. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELQ CONDITI4NS AND ACTUAL WATER HEATER. SET WATER HEATER THERMOSTAT AT 1 0' FA . 4 HRENHEIT PROVIDE SEfSMIC STRAP OR BRACING AND FLEXIBLE CONNECTORS TQ WRTER AND GAS C4NNEGTIONS IF/AS REQUIRED BY LOCAL AUTHORITIES. ROUTE A�L DRAIN LINES TO NEAR WASTE RECEPTACLE WITH A TWO PIPE AIR GAP. 1 REwE A EA NOT TO SCA�E MOUNT VACUUM BREAKER ABOVE FIXTURE BACKSPLASH, MINIMUM 6" ABQVE FLOOD RIM. DRI�L BACKSPLASH FOR PIPES. PROVIDE SI�ICONE SEALANT AROUND PIPE THRU BACKSPLASH. USE CHROME P�ATED PIPE EXPOSED ABQVE BACKSP�ASH. Yz' WATER �--1Yz" VENT IN WALL VAC U U M FLOW BREAKER �pNTRO� ���BE FI}�TURE (SINK OR VALVE PIPE GQ�E OR UNION TROUGH) SOLENOID V GARBAGE DISPt�SER VALVE BY FSEC BALL VALVE � N C� USE HUBLESS CAST IRON PIPE AND � C4NNECTORS WATER HAMMER ARRESTER 2" P-TRAP �- 3" WASTE DQ NflT CONNECT TO GREASE WASTE � REFER TO FOOD SERVICE EQUIPMENT DOCUMENTS FOR ITEMS FURNISHED AND WORK PERFORMED BY FOOD SERVICE EQUIPMENT CONTRACTOR (FSEC). ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIE�D CONDITIONS. WIRING IS BY E�ECTRICAL CONTRACTOR. A A 1 NOT TO SCALE PIPE SIZE AS REQUIRE� � SEE DRAWINGS - - - DECK PLATE, RIGID 18 GA __ STAINLESS STEE�, MIRO INDUSTRIES #DP-i2-SS, " SIZE 12" SQUARE , �=_ �� �� � � � • � -- � r-� -�- • s �_ • - - =►E :� PI�LOW BLOCK PIPE ��� ALUMINUM PIPE STRAPS. STAND OF POLYCARBONATE FASTEN TO PIPE STAND RES1N MATERIAL, MIRO WITH STAIN STEE� SCREWS, INDUSTRIES #1.5/3-R PLAN MIRO INDUSTRIES, #1.5f3-R PIPE STRAPS PIPE SHA�L REST �IR��Y PI�LOW BLOCK PIPE ON PIPE STAND WITHOUT STAND GAPS PiPE STANDS ARE QECK PLATE STACKABLE FOR PROPER ELEVATION OF VARIOUS � � SIZE PIPE TO P�AINTAI�J LEVEL/S�OPE PIPING. ROOF �-�- - -�-� MIR4 INDUSTRIES, ELEVATION #1.5/3-R SPACER PIPE STAND GOOD FOR 1/2" TO 3-1/2" STEEL PIPE SIZES ON�Y. SUPPORT SPACING FOR PIPE 51ZE: 1/2"=6'-0'°; 3/4" & 1"=8'-0"; 1-1 J4" AND IJ�RGER=10'-0". PIACE DECK PLATES ON ROOFING, SET PIPE STAND FREE ON DECK PLATES. STACK PIPE STAND WITH SPACERS, WHERE REQUIRED TO ELEVATE PIPING. INSTALL GAS PIPE TO ALLOW FQR EXPANSION AND CONTRACTION. PRIMER COAT AND PAINT EXTERIOR GAS PIPE LIGNT GREEN GOLOR. L I IP NOT TO SCA�E STEEL , , DRIL�ED-IN DECK � THREADED INSERT TOP BEAM IF EXISTING PAN C-CLAMP ALL-THREAD ROD. FLOOR OR CAST IF STEEL LENGTH AS REQUIRED IN PLACE IF NOT BAR JOIST FOR PIPE SLOPE� EXISTING DO NOT USE SHOT-IN PROVIDE COPPER INSERTS OR NON-METALLIC ADJUSTABLE COATING WHERE BAND HANGER HANGERS CONTACT FOR PIPING BARE COPPER PIPE CLEVIS HANGER FOR FOUR INCH O� PIPE OVER FOUR INCH OR LESS-----r i i i o DO NOT HANG PIPE PROVIDE GALVANIZED STEEL SADDLE FOR ALL LARGER THAN 3" FROM INSULATED PIPE �ARGER THAN 3/4". VERIFY 80TfOM OF JOISTS INSULATI4N THICKNESS WHEN SIZING HANGERS PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. HANGER SPACING FOR PIPE SIZE: COPPER: 4°'=12'-0°'; 3"=11'-0"; 2Yz"=10'-0"; 2°'=9'-0"; 1Y2,°=8'-0"; 1Y4"=7'-0°; 1" & 3/4"=6-4,,,; Ya��=5'-0". CAST IRON: 10'-0" AND ONE NEAR ALL JOINTS. STEEL: 4"=14'-0"; 3"=12'-0"; 2Yz"=11'-0°; 2"=10'-0"; 1Y2"=9'-0,'; 1"=7>-0,,; 3/4„=6'-0'°; Yz��=5'-0". LOCATE HANGERS AS CLOSE AS PUSSIBLE TO TURNS AND TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL STRUT5 BETWEEN JOISTS IF REQUIRED. LOCATE HANGERS TO TAKE �OAO OFF OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES PN WATER VELOCITY. PROVIDE SEISMIC BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP iRON OR STEEL IS NOT ACCEPTABLE. REFER TO CODES AND SPECIFICATIONS FOR FURTHER INFORMATION. NOT TO 5CALE PRQVIDE CLEANOUTS IN TURNS/ENDS OF PIPE. USE DWV FITfINGS IF SiZE IS LARGER THAN 1°' DISCHARGE INTO CENTER HOLE OF � GRATE OF WASTE RECEPTACLE WITH AIR GAP SUFFICIENT TO REMOVE GRATE AND STRAINER. MINIMUM SLOPE PIPE AS GAP = TWO PIPE DIAMEfERS MUCH AS /^� POSSIBLE TOWARD \ \`.%� DISCNARGE MAKE CONNECTION TO �'� I � EQUIPMENT AS REQUIRED l MAKE PIPE MINIMUl� ONE SIZE �ARGER VERIFY WITH �OCAL CODES THAN EQUIPMENT C�NNECTi4N, MINlMUP� �FJWHE(V TRAP ANDjOR 1/E�T 3/�". USE TYPE "M" NARD COPPER UP ARE REQUIRED FOR THE LEPIGTH TO i°' AND TYPE DWV FOR LARGER OF DftAIN PIPE INSTALLED RC3UTE PIPE INCONSPICUOUSLY AND UNQBTRUSIVELY. f�ANG PIPE AS REQUIRED. D4 NOT INSUI�TE INDIRECT DRAIN PIPE WHEN INSTALLED EXPOSED IN FOOD SERVICE FACILITY. REFER TO LOCAL C4DES FOR FURTHER INFORMATIONo NOT TO SCALE PROVIDE A COMPLETE FREEZE PROTECTION SYSTEM FOR CONDENSATE PIPING IN FREEZE BOX EQUIVALENT TO RAYCHEM/TYCO #5XL-1-CR @ 120V, 15A OR #5X�-2-CR � 208/277V, 15A WITH AN OUTPUT OF 5 WATfS PER FOOT AND 40'F START-UP TEMPERATURE. PROVIDE 1" ELASTOMERIC INSULATION OVER FREEZE PROTECTION ON CONDENSATE LINE - IF/WHEN FREEZER BOX ONLY - {ELECTRIC HEATING CABLE IS BY OTHERS) SILICONE SEAL AROUND PIPE PENETRATION �1 °� --- DX COIL CO - a � i CO PROVIDE TRAP AT PROVIDE CLEANOUT BOTTOM OF RISER AND IN TURNS AND ENDS DISCHARGE INT4 FLOOR OF PIPE DRAIN OR FLOOR SINK MAKE CONNECTION TO WITH AIR GAP OF TWO COIL AS REQUIRED PIPE DIAMETERS NO INSULATION ON PIPE RISER WALK-IN COOLER OR FREEZER BOX FLOOR SEE FLOOR PIAN FOR RECEPTACLE LOCATION. INSTALL PIPE HIGH AS POSSIBLE, ANCNORED TO WA�L OF BOX WITN SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE IYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLQER JOINTS. SLOPE HORIZONTAL P9PE AT MINIMUM TWO PERCENT. REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUiREMENTS. _ / NOT TO SGALE DOMESTIC COLD WATER LINE IN PLUMBING CHASE OR UNDER FIXTURE. MAKE BRANCH TO TRAP PRIMER OFF TOP OF THIS PIPE TRAP PRIMER IN CHASE OR UNDER FIXTURE. TRAP PRIMER INSTAL� PRIMER MINIMUM SIX INCHES ABOVE WITH INTEGRAL FLOOD RIM OF FIXTURE BEING SERVED VACUUM PROVIDE QISTRIBUTION UNITS WHERE MORE BREAKER THAN ONE TRAP 9S SERVED 8Y A PRIMER �`'`- PRIMER MAY BE LOCATED ABOVE CEILING PROVIDE 'NHERE ACCESSIBLE. IF L�CATED IN A COUPLING CHASE OR WA�L, PROVIDE A HINGED, LOCKABLE, PRIME COATED ACCESS DOQR IN AN AGCESSIBLE BUT INCONSPlCUOUS PLACE � .. � < \` — - - - - - - CONCRETE F�OOR TYPE "K" SOFT COPPER TIJBE BELOW Fi.00R SLR� VdITHOUT JOINTS. SLOPE TOWARD FLfl4R DRAIN TRAP. FLO�R DRAIN OR FL40R PROVIDE ELASTOMERIC INSULATION SiNK P-TRAP N1ETH TRAP FROM TRAP TO ABOVE FLOOR SL.AB PRIMER CONNECTION TRAP PRIMER MAY BE LOCATED ABOVE CEILIt�G WHERE ACCESSIBLE. NOT TO SCALE RECIRGULATION PUMP ON TIME FULL PORT BALL SHUT-OFF VALVES (TYP) CLOCK, COORDINATE WITH STRAINER �WNER FOR ON/OFF TIMES STRAP-ON AQUASTAT SET 5 DEGREES LOWER THAN HEATER TEMPERATURE (135°) CHECK VALVE (TYP) 3�4„ 2y2" I--� 7y2� 2� 2 HOT WATER TO FIXTURES � 2°° �� �4 _ ' _ AS SHOWN ON P�ANS 2 PIPE UNIONS, DIELECTRIC FROM WATER 1 1Y4" 2" 1Ya" REQUIRED FOR DISSIMILAR SOFTENER � �y2„ c� �Y2„ 1y4" a� 1Ya" METALS {TYP) EXPANSIQN — I I TANK .�____----6" LONG DIRT LEG (TYP} u u u INTAKE C � C GAS SHUT QFF COCK (TYP) 1 ' ' GROUND JOINT UNION (7YP) 1Y2>� WATER ly2.a WATER 1Y2°a WATER HEATER NEATER HEATER PROVIDE A 210' F TEMPERATURE AND EXHAUST/INTAKE (TYP) {TYP� �-�p� 150 PSI PRESSURE RELIEF VALVE WITH PIPES, REFER TO TEST LEVER SIZED WITH AGA/CGA PLANS FOR TEMPERATURE STEAM RATiNG 147 OVER CONTINUATI4N HEATER INPUT (TYP) EXHAUST HARD COPPER RELIEF QISCHARGE (�jN I � {�H I � (�H I � LlNE, FU�L SIZE OF VALVE OUTLET TO � END OVER U/ASTE RECEPTACLE WITH FINISHED FLOOR TWO PIPE AIR GAP (TYP) SET WATER HEATER ON MASONRY UNITS {TYP) REFER TO SPECIFICATIONS AND PLUMBING FIXTURE SCHEDUL.E FOR WATER HEATER. PIPING ARRANGEMENT SHQWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS AND ACTUAL WATER HEATER. SET WATER HEATER THERMOSTAT AT 140' FAHRENHEIT. PROVIDE SEISMIC STRAP OR BRACING AND FLEXIBLE CONNECTORS TO WATER AND GAS CONNECTIONS IF/AS REQUIRED BY LOCAL AUTHORITIES. ROUTE ALL DRAIN LINES TO NEAR WASTE RECEPTAGLE WITH A TWO PIPE AIR GAP. ' E E EA ERS 1 NQT TO SCALE PROVIDE ONE PIECE SPUN ALUMINUM BASE WITH, GRADUATED STEPPED PVC BOOT, AND ADJUSTABLE STAIN�ESS STEEL CLAMPS. SEf BASE IN BED OF MASTIC REFER TO ARCHITECT'S I I DRAWING FOR APPLICAi'ION MINIMUM 12" ABQVE ROOF OF VENT PIPE BOOT INSTALLATION WITH ROflFING MATERIAL RQ4F iNSULAT101� I� �j �!� I,I ROOF aECK ii� n' PROVIDE SLEEVE IF ANCHOR PIPE TO ROOF DECK t�R REQUIRED BY TYPE J�ISTS WiTH U-BO�T ,4ROUND OF ROOF DECK PIPE AND ANG�E IRON WELQED OR SCREWED T� DECK OR JOIST MINIMUM 12" BELOW ROOF PROVIDE PiPE lNCREASER WHERE REQUIRED TO MAKE � HUB�ESS PIPE CONNECTORS MINIMUM 3" VENT THRU ROOF QN CAST IRQN PIPE REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR A MINIMUM OF 15 FEET HORIZONTAL (UNLESS APPROVED BY ENGINEER PRIOR TO INSTA�LATION) OR THREE FEEf VERTICA� ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE. PROVIDE 1" FIBERGLASS INSULATION WITH ALL-SERVICE JACKET ON VENT PIPE INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY FLASHING AND COUNTERFLASHING WITH ROOFING CONTRACTOR. t T ) NOT TO SCALE THIS SHEET IS PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY. THAT SH4WN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNEQ AND SEALED PER STATE REQUIREMENTS. r • \ I RS�N � Larson Binkley, Inc. T 816-997-9601 310 W 2ath 5treet, Suite 200 F 816-997-9602 Kansas City, MO 64108 larsonbinkley.com Copyright 2014 .' ` ¢`P,.... ,R,9 '�i ``�•PpQti�,�sfE;q�o,��' �i � : : : : � No.11300274 - � • : STATE C?F a :•� :�. ��'' � .. .�y . . ` . • , �, • '''o'�'F''�;D 1 AN,�' �`�'.`1. '`''rsS,ONA; �� ` � �' � C � '< . �' � � • � �,, . � . . , • . . . . � . � � � � .. . . - . . .. . r III �� � � � � . � � . � � •� � � . �: J' �' � i' . � DATE: 07. I 6.20 I 4 DRAWN BY: ESC FI�E: K:\FiixBrewhouselCarmel0 REVISIONS: o - - COPYRIGHT 2013 JKR PARTNERS ��C Al.l RIGHTS RESERVED � . . �e, MEN'S TC?ILET ROC7M 113 �: J FFCO A1 � 2�/ � \ 1Y� �� 2„ r I1Y2°' 73 \:J � / 1Yz" 1Ya„ 2,> / wco WCO 2„ �/ I1Y2» 3» �2» � �y2„ / i I iY2�� 2>, �p 2" � 2" 2» � � L 3„ �Y2„ \ / O I I.� � � � 3>, (� 3 �y2» r' > I 3„ � I LJ 3" � FERMENTATION 3' / � G� 3" 1Y2�� �.� I1Yz" D�202 Y 3 ,/� / I � \ 2„ C� 1 � 3„ .�,� 3�� G� � �� 3» 1Yz�� .� � � �_�� � ''� � � FFCO � ,/� O 281 3�� � �, �. �» 2,. G�, 2 /''� �. 3 I 2" 3» 4, 3 � \ 2„ 3a, �/ .,� \ l�J � .� � 1Yz„ �. BAR 2» 2» ` FFCO \ / WCO / I 3� \ 3" �,,�! i ioA �S 3 �� I � /,,, O -'/ , �C�, 1Y2„ � � �/ 3" �,.� 3,� 3,� � 2� I /'� 3„ �,3� 3" I /r \ 2„ % /" \. 3„ �• � ,,� 3„ �, �„ 2„ ,� I �y2» � � 3>. � WCO �„ 1Y2" �„ ly2=a' ` 2 °\ �' O 1Yz" ��y 3>, /' (� 1Y2„ /.% �,/ FFCO '�-' / � 1 c� \ 2„ �„ y „ L� 259 �p z 3„ I / �/• 4° �y2 3,� 238 � r' 3" 2�� 2» 1Yz" � 3 I < 3" 1Y2" 1Y2" \ 3 3>� c� 2„ � � � � �„ 3.j. 4„ �„ 2„ / 3�� �/ � % �o> 2„ 1Y2�� FFCO l y20! 81 2� 3" �,� 3'� 4„ I3„ FFC4 39' 1Y� 4„ 1Yz" 4>, wco 3„ _c� o WCO � 4 4 � I 2 �Y2 D wco 9D 2�� � 301 3°' 2>, 2„ 2 y 1Y2" 3„ �' -----__ / �» � 2" O 1Y2„ ,y2„ �,> � 3,> ��\�-" ----___-�_ , / � �Y" �„ o _ ''� '\ �„ 2,� 1Yz"�_. % �1Y2 2., /'� � �--�_ _ f 3>, �>, 173�� / /� 2„� 1Y2>, WCO �,,� \ wco r D )/^,.��` {] Z // � � � O /' e 00 \ ' I ) ' SJ � J'} / I � � 99 I% G� 3 -� / 2„ / �a� �.: � Z„ ' \` 3>, ---___ __ __�,_,,, 3 0, � I 2., � 2„ c� /'� 2., L/ ('� 131 1Yz" Z>, I \� � �-- � 3 I 2/ Q 2„ I2„ \ � 4"VTR � � �„ � '� 2„ \` G,� I \ r'/�`lY2' I �w I\ 2°° 2„ 1Yz°' \ 3�> `� 4, 4„ q✓� 181 4„ 2a° 81 2„ \� \ � �. 2„ / 3„ 2» � 2„ FFCO � �„ 2,0 1Y2„ � 3,> 2„ 2a, 3„ 2 �>, 2„ �,� 18i 1Yz„ 2" KiTC�EN 2" �Y2„ �„ iz6 2a� / L 2>, 3�� �� 1Y2„ � ( 4„ 2„ 2P> �,> 3>, L 1Y29> 1Y2" 4„ ��v �,> 20, . 1Yz" ��z„ 4„ 2>, 3„ � 2., „I 1Yz" G� �,o � �� � � 1Y�„ 1Yz 4�„ BREWERY H G'� 2" �„ 29= C715PLAY ,y Z" 2„ 2„ i i i � 3„ 1Y2 2„ � lJ 1y�» � 2" BREWERY L D �'� 2 � �' 2>, 1�,z /� G1ISPLAY Gyy 4„ � 1Yz�� L 2„ �" � 4"VTR I /, �>, ,/ 2oi �yZ�> 1 `4„ ,,� � � 9 1Y2'= V � � I �-' ��. ,�- 3>. I � � .�.J �i�2�° `� WCo G 1 � � 2„ � � 3,. I 4" I / �.�' 3" DRAIN LINE BELOW �G � �, MEZZANINE DECK � 2°' 2„ 4„ 3„ I 4�� � y2P, �„ 4„ (� I I � 4sa _ � / / I1YZ„ 3„ 3„ �=/ I I �„ 3>, FFCO I i 4" 4�� I WCO FFCO � I � 3" ,> 1yz., 3 � i 2Q6 2„ O 3„ � a -•�y2„ `�.2" I 4" � / I ` 3 °' 3„ \ � �,,/ 4 ' /� .� r 4 0, � e I I �2„ �" � l,,-' .� I 2,0 � 2„ � � r I , y2>, .� 4„ (' I 1y2„ I 2 �- ,�' � I �"-� I � 2�� � -- � � 2„ �.c. ,y2„ � ,/ I �. c. I� 1 15 � � q'a> �4�� �'���, / 122 4' � 1Yz" 4>, / �„ 1Y2„ 2„ �/ WCO 2�� 1Y2" �0 3°' iY2" 2" 1y2�' 4>, E 2,a 2�� � I FFCO 1�„ 2„ E �„ � � I ./ 'f 1y2>, 2„ 3„ � >Y2�, 12,� ' �2�� � 2�� FAMILY 1Y2��1 B1 I ' I % \ „ TOILEI" � I �>, ` 4„ 2„ 9c,.� � 2 �, 3" 2,o WCO 123 I4„ � „ 2, 4> � , 4>, /,, 2„ � � 2 rii� ,> I 2„ 4 4» �,/ 4' � I � 4,� 2 4,o Q WOMEN's 4„ \ % �y2„ \ A1 WCO 4�� TOILET ROOM \ � \ 4>' � 2>s 4e: 1 4„ n i i a ' .� � I '� � 4» � �._.J \ \ 4„ {E)FFCO I 4 � \ lY�Bf 1Yz" 4" 2" _ �' 3„ � ____--------- _.________________ ------------ ----- �(E}4" �a FFCO 2a, _.____._________. _____________- 4�= \ � 2„ 2,> �„ � 1Y2„ � 1Y2„ 2„ (E)4�' \• � „�.�J - „ I WCO 2" � � 2 2 �� IIYz» 2�� SERVER 4' �� � � 2" STATI O N 4�= 2,� .� � 2,� 2„ � 1Y2�� 2„ A12„ � 2�° 2,> �>, 2,> � � 2„ � 1Y2„ 2» ° 1Yz" � 2„ A1 � 2a, B 1Y2„ 4„ � 4�, 2>, 1Y2» \ D � 2" 3ma 2�, r�EN�s �„ 4a. 2„ � 2�� ��� TOILET RQOh1 � A 2,n / i z i 2„ � 1Yz" 2„ 4,. 4„ = 2„ � �„ � �,> 4�a 4,a lyZ>, � �„ 2„ �, 2,. � A �,a 4>� �„ 2„ � 2„ � A FFCO 4�� � � �,� 4,9 ' 4�y � A1 Ai WCO 1i'2�� �,> 4�> 1Y2,> � ` WOMEN'S 4° 4�� TOILET ROOM �zo 4„A I{E)4,?� 1Yz" 4„ ` 1Y2� I��K�] \ �Y2„ O 1Yz„ � . �; THIS SHEET IS PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIQNS APPLY. THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. YERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONA� ENGINEER HAS NOT SIGNED AND SEA�ED PER STATE REQUIREMENTS. � \ \ J RS�N � Larson Binkley, Inc. T 816-997-96Q1 310 W 2Qth Street, Suite 200 F 816-997-9602 Kansas City, MO 64108 larsonbinkley.com Copyright 2014 _ '', `� �,\PN.r:..,�,9 °'°ir ``'\ �•'tiG,�ST�'Rc�,�-,''' ` 4; � O :�' i 1: � � ' No.11300274 � • ; STATE OF � • _ .- .,p : Q � � ` .p' , �.��t/ ''�''Q'�`' NC7iANP*•',�`.`': ��,,��S,ONA� E��+ '``� C �'t 5 C �' . � • � � • y i r �'�! � � � �. � • � � � � � � �7����1�[.�e �7C� � : ��7�1�3'��c[!� � . , � . . � � a i � � •, • . - •� • . • r � � � . � � . � FILE: K:\FlixBrewhouselC:armei\ � - . f COPYRIGHT 2013 JKR PARTNERS LLC ALL RIGHTS RESERVED '� . .