HomeMy WebLinkAbout037 IMPA Bid Set 3 - L503.pdfS H E E T N U M B E R
D R A W N B Y
C H E C K E D B Y
C E R T I F I C A T I O N
R E V I S I O N S
IN
D
I
A
N
A
M
U
N
I
C
I
P
A
L
PO
W
E
R
A
G
E
N
C
Y
11
6
6
0
N
O
R
T
H
C
O
L
L
E
G
E
A
V
E
N
U
E
CA
R
M
E
L
,
I
N
D
I
A
N
A
JBB
JDA
BI
D
S
E
T
3
05
.
2
1
.
2
0
1
4
L
A
N
D
S
CAPE
A R C H I T ECT
J
DE
R
No. 0900153
STATE OF
L503
1-1/2"O.D. Aluminum tube steel
railing, painted finish, with 4"
embedded mounting, core-drilled and
epoxy set in place with caulked joint
#4 Rebar @ 12"o.c.
Main Entry Central Stair Section
#4 Cont. rebar reinforcement
01 Scale: 1" = 1'-0"d-sect-conc rain wall
Compacted aggregate base
Compacted subgrade
Cast-in-place concrete stair
1'-0" Typ.
NOTES:
1. Provide 1% Slope to front of
stair treads for positive drainage.
2. Provide 1/2" radius to nose of
stair treads
8 3/4"7 1/4"8"
8"
Entry Stair Planter Section03Scale: 1" = 1'-0"d-sect-conc rain wall
6'-0"
1'-0"4'-0"1'-0"
Amended topsoil
(Refer to Planting Plan)
Non-woven Filter fabric
FINISH GRADE
8"8"
TW
8"4"
3"
Compacted aggregate base
#4 Horiz. rebar @ 12"o.c.
#4 Vert. rebar @ 12"o.c.
Compacted subgrade
Expansion joint and adjacent
material. See plans.
Limestone veneer, cell vent at
base, 4' o.c.
Cast-in-place concrete wall
NOTES:
1. Top of concrete wall and veneer
ledge to slope with grade. Refer to
Grading Plan
2. Refer to DETAIL 04, L504 for
limestone veneer pattern
Dovetail anchors at base of each
veneer panel in 3/8" max mortar
joint
Dovetail anchor channel, 24" o.c
Underdrain, refer to Civil
Engineering plans
Drainage stone backfill
Limestone Coping03
L504
Wall Mount Bench - Provide 6" x 4", 1/4"
thick, galvanized and primed Steel Tube
(inside and out) for Attachment. Mount
through steel to concrete wall beyond
with stainless attachment anchors.
1'-0"
8"8"1'-0"
Entry Stair Ramp Section02Scale: 1" = 1'-0"d-sect-conc rain wall
7'-0"
8"8"
1'-0"5'-0"1'-0"
TOP OF RAMP
BOTTOM OF RAMP
TW TW
Compacted aggregate base
#4 Horiz. rebar @ 12"o.c.
#4 Vert. rebar @ 12"o.c.
Compacted subgrade
Expansion joint and adjacent
material. See plans.
Limestone veneer, cell vent at
base, 4' o.c.
Cast-in-place concrete wall
NOTES:
1. Top of concrete wall and veneer
ledge to slope with grade. Refer to
Grading Plan
2. Refer to DETAIL 04, L504 for
limestone veneer pattern
Dovetail anchors at base of each
veneer panel in 3/8" max mortar
joint
Dovetail anchor channel, 24" o.c
FINISH GRADEFINISH GRADE
8"4"
3"
Limestone Coping03
L504
1'-0"8"8"1'-0"
North Stair Section04Scale: 1" = 1'-0"d-sect-conc rain wall
Compacted aggregate base
#4 Rebar @ 12"o.c.
Compacted subgrade
Cast-in-place concrete stair
8"
NOTES:
1. Provide 1% Slope to front of
stair treads for positive drainage.
2. Provide 1/2" radius to nose of
stair treads
6 1/4"2'-1"1'-0"
1'-3 1/4"
8 3/4"10 7/8"
6'-7 1/4"
1-1/2" O.D. Aluminum tube steel
railing, painted finish, with 4"
embedded mounting, core-drilled
and epoxy set in place with caulked
joint
#4 Cont. rebar reinforcement