HomeMy WebLinkAbout050 IMPA Bid Set 3 - LS01 - Revised for State.pdfRA M P DO W N RAMP DOWN RA M P DO W N DN . (5) RISERS @ 6" (8) R I S E R S @ 6 " (8) R I S E R S @ 6 " AS S E M B L Y ( A ) W/ O F I X E D S E A T S ( U N C O N C E N T R A T E D ) 7, 5 8 2 s f / 1 5 = 5 0 6 O C C U P A N T S + AC C E S S O R Y S T O R A G E / M E C H . 1, 9 9 3 s f / 3 0 0 = 7 O C C U P A N T S T O T A L O C C U P A N T L O A D = 5 1 3 R E Q ' D E X I T W I D T H ( 5 1 3 x 0 . 1 5 ) = 7 7 . 0 " PR O V I D E D E X I T W I D T H = 1 8 0 . 0 " BU S I N E S S ( B ) 4, 5 2 9 s f / 1 0 0 = 4 6 O C C U P A N T S + AC C E S S O R Y S T O R A G E / M E C H . 67 3 s f / 3 0 0 = 3 O C C U P A N T S T O T A L O C C U P A N T L O A D = 4 9 R E Q ' D E X I T W I D T H ( 4 9 x 0 . 1 5 ) = 7 . 4 " PR O V I D E D E X I T W I D T H = 7 2 . 0 " AS S E M B L Y ( A ) W/ O F I X E D S E A T S ( U N C O N C E N T R A T E D ) 4, 9 7 9 s f / 1 5 = 3 3 2 O C C U P A N T S + AC C E S S O R Y S T O R A G E / M E C H . 93 5 s f / 3 0 0 = 4 O C C U P A N T S T O T A L O C C U P A N T L O A D = 3 3 6 R E Q ' D E X I T W I D T H ( 3 3 6 x 0 . 1 5 ) = 5 0 . 4 " PR O V I D E D E X I T W I D T H = 1 8 0 . 0 " EX I T @ G R A D E EX I T W I D T H : 3 6 " EG R E S S WI D T H : 7 2 " EX I T @ G R A D E EX I T W I D T H : 7 2 " EG R E S S WI D T H : 7 2 " EG R E S S WI D T H : 4 0 " MA X . T R A V E L DI S T . = 2 4 3 ' - 8 " EX I S T I N G EX I T @ G R A D E EX I T W I D T H : 7 2 " 56 ' - 0 " DI S T . B E T W E E N E X I T S 99'-1 " MAX. O V E R A L L D I A G . D I M . (33' D I S T . A L L O W E D B T W N E X I T S ) EX I S T I N G EX I T @ G R A D E EX I T W I D T H : 3 6 " 10 7 ' - 8 " M A X . O V E R A L L D I A G . D I M . (3 5 ' - 1 0 " D I S T . A L L O W E D B T W N E X I T S ) EX I S T I N G EX I T @ GR A D E EX I S T I N G EX I T @ G R A D E EX I T W I D T H : 3 6 " EX I S T I N G EX I T @ G R A D E EX I S T I N G EX I T @ G R A D E EX I T W I D T H : 3 6 " 36'-3" DIST. BE T W E E N E X I T S MA X . T R A V E L DI S T . = 9 9 ' - 1 1 " MA X . T R A V E L DI S T . = 1 1 8 ' - 9 " EX I T @ GR A D E EX I T W I D T H : 3 6 " EX I S T I N G EX I T @ G R A D E EX I T W I D T H : 3 6 " AS S E M B L Y ( A ) NU M B E R O F E X I T S R E Q ' D . = 3 NU M B E R O F E X I T S P R O V I D E D = 3 AS S E M B L Y ( A ) NU M B E R O F E X I T S R E Q ' D . = 2 NU M B E R O F E X I T S P R O V I D E D = 5 BU S I N E S S ( B ) NU M B E R O F E X I T S R E Q ' D . = 1 NU M B E R O F E X I T S P R O V I D E D = 2 EG R E S S WI D T H : 7 2 " 106 ' - 7 " MAX . O V E R A L L D I A G . D I M . (35 ' - 6 " D I S T . A L L O W E D B T W N E X I T S ) 4 0 ' - 2 " S H E E T N U M B E R D R A W N B Y C H E C K E D B Y C E R T I F I C A T I O N R E V I S I O N S 1043 Virginia Avenue, Studio 211 Indianapolis, Indiana 46203 phone/fax 317.803.7900 www.blacklinestudio.net INDIANA MUNICIPAL POWER AGENCY 11660 NORTH COLLEGE AVENUE CARMEL, INDIANA RT AR 1 9 9 0 0 1 1 1 A C R HC E T I ST A T E O F B T T OCS No . TSI G E R ERED NETR A EP KSNI I A N A DNI XX X X XX X X BID SET 3 05.21.2014 1 ST A T E R E V I E W C O M M E N T RE S P O N S E S 0 7 . 1 8 . 1 4 LIFE SAFETYLS 0 1 Li f e S a f e t y P l a n 1/ 1 6 " = 1 ' - 0 " PL A N L E G E N D TW O H O U R F I R E R E S I S T I V E C O N S T R U C T I O N ME A N S O F E G R E S S TR A V E L D I S T A N C E P A T H GENERAL NOTES:A.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION ANDSHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY.B.CONTRACTOR SHALL CAREFULLY STUDY ALL OF THE CONTRACT DOCUMENTS AND SHALL VERIFY ALL EXITINGSITE CONDITIONS WITH CONSTRUCTION DOCUMENTS PRIOR TO PROCEEDING WITH ANY PORTION OF THE WORKAND TO NOTIFY THE ARCHITECT OF ANY VARIANCES.C.CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD.D.ANY CONDITIONS, MATERIALS, DEVICES OR DETAILS NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BECLARIFIED WITH THE ARCHITECT BEFORE CONSTRUCTION INSTALLATION OR APPLICATION. GENERALSUBCONTRACTORS SHALL COMPLY WITH ALL GOVERNING CODES, BUILDING REGULATIONS OF FEDERAL, STATE,CITY AND COUNTY, WHICHEVER GOVERNS THE CONSTRUCTION WORK.E.GENERAL AND/OR SUBS SHALL PAY FOR ALL PERMITS AND FEES AND ARRANGE FOR INSPECTION BYAUTHORITIES. THEY SHALL MAKE ARRANGEMENTS AND PAY FOR WORK TO BE DONE BY UTILITY COMPANIESPERTAINING TO THIS WORK.F.ALL MATERIAL CALLED OUT ON DRAWINGS ARE TO BE NEW UNLESS NOTED OTHERWISE OR "EXISTING".G.EACH TRADE SHALL BE RESPONSIBLE FOR ANY LOSS OR DAMAGE TO THE OWNER OR THE WORK, MAKE GOODANY LOSS, DAMAGE OR INJURY WITHOUT COST TO THE OWNER.H.KEEP PREMISES FREE FROM ACCUMULATION OF TRASH AND DEBRIS.I.UPON COMPLETION REMOVE ALL FOREIGN MATERIALS FROM ALL EXPOSED SURFACES.J.CONFINE ALL OPERATIONS TO AREAS OF WORK AS SHOWN. KEEP AREAS ADJACENT TO THE WORK CLEAR ATALL TIMES.ARCHITECTURAL GENERAL NOTES:A.THESE NOTES APPLY TO ALL ARCHITECTURAL DRAWINGSB.DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.C.PAINT ALL NEW EXPOSED STEEL LINTELS, HANDRAILS, LADDERS, BEAMS, COLUMNS, ETC. IN ALL AREAS UNLESSOTHERWISE NOTED.D.INTERIOR WALL STUD SPACING SHALL BE 16" O.C. UNLESS OTHERWISE NOTED.E.SEAL ALL COUNTERTOPS AT JUNCTURE WITH WALL AND INSET ITEMS IN COLOR TO MATCH SURFACE.F.CONTRACTOR SHALL VERIFY ALL ACCESSORY/EQUIPMENT/CASEWORK MOUNTING HEIGHTS AND PROVIDE SOLIDBLOCKING FOR ALL WALL MOUNTED ITEMS THAT REQUIRE ANCHORAGE. COORDINATE WITH MANUFACTURER, ORWHERE INDICATED, WITH ARCHITECT.G.PROVIDE UNDERCUTS AS REQUIRED FOR DOORS WHERE CARPET IS TO BE INSTALLED.H.FLOOR FINISH TRANSITIONS AT DOORS SHALL ALIGN WITH STOP SIDE OF DOOR AND CONTINUE UNDER DOOR SOTHAT ALL TRANSITION MATERIALS ARE COVERED BY DOOR WHEN IN CLOSED POSITION. ALL FINISH FLOORTRANSITION AND REDUCER STRIPS SHALL BE PROVIDED BY FLOORING CONTRACTOR.I.ALL WORK SHOWN ON THESE DRAWINGS AND IN THE SPECIFICATIONS SHALL BE BASE BID, UNLESS OTHERWISESPECIFICALLY NOTED TO BE BY ALTERNATE BID.J.ADDITIONAL CHASES AND BULKHEADS MAY BE REQUIRED FOR HVAC, PLUMBING, AND ELEC. EQUIPMENT. ON E H O U R F I R E R E S I S T I V E C O N S T R U C T I O N BUILDIN G S U M M A R Y : OCCUPANCY C L A S S I F I C A T I O N : A & B CONSTRUCTI O N T Y P E : V B ALLOWABLE A R E A ( I B C T A B L E 5 0 3 ) : FOR A - 3 , T Y P E V B C O N S T R U C T I O N : 1 S T O R Y , 6 , 0 0 0 S F AUTOM A T I C S P R I N K L E R S Y S T E M I N C R E A S E ( I B C 5 0 6 . 3 ) : A D D I T I O N A L 1 8 , 0 0 0 S F FRONT A G E I N C R E A S E ( I B C 5 0 6 . 2 ) : If = [ F/ P - 0 . 2 5 ] W /3 0 If = [ 8 6 6 / 8 6 6 - 0 . 2 5 ] 3 0 / 3 0 If = [ 1 . 0 0 - 0 . 2 5 ] 1 If = 0 . 7 5 AREA M O D I F I C A T I O N E Q U A T I O N ( I B C 5 0 6 . 1 ) : Aa = At + [ At x If ] + [ At x Is ] Aa = 6, 0 0 0 + [ 6, 0 0 0 x 0. 7 5 ] + [ 6, 0 0 0 x 3] Aa = 6, 0 0 0 + [ 4, 5 0 0 ] + [ 18 , 0 0 0 ] AL L O W A B L E A R E A ( Aa ) = 2 8 , 5 0 0 s f AREA SUMMA R Y : EX I S T I N G = 12 , 6 4 7 s f AD D I T I O N = 15 , 4 6 2 s f TOTAL B U I L D I N G = 28 , 1 0 9 s f BUILDIN G A R E A L I M I T S D I A G R A M ( I B C 5 0 2 ) BU I L D I N G A R E A OCCUPANT LO A D : OFFIC E = 4 5 2 9 s f / 1 0 0 = 4 6 ASSEM B L Y ( U N C O N C E N T R A T E D ) = 1 2 6 3 0 s f / 1 5 = 8 3 8 ACCES S O R Y S T O R A G E / M E C H . = 3 0 1 3 s f / 3 0 0 = 1 4 TOTA L O C C U P A N C Y = 8 9 8 FIXTURE COU N T P E R I B C C H . 2 9 & 6 7 5 I A C 1 3 - 2 . 5 - 2 8 , C H A P T E R 2 9 , S E C T I O N 2 9 0 2 - USING ACTUA L O R A N T I C I P A T E D # O F O C C U P A N T S F O R A S S E M B L Y S P A C E S : ASSEM B L Y + S T O R A G E / M E C H . A S S O C I A T E D W / A S S E M B L Y : 15 0 + 3 0 0 + ( 2 , 9 2 8 / 3 0 0 ) = 4 6 0 46 0 / 2 = 2 3 0 M E N , 2 3 0 W O M E N RE Q ' D . ME N W . C . = 1 / 1 2 5 2 WO M E N W . C . = 1 / 6 5 4 TO T A L L A V . = 1 / 2 0 0 3 BUSIN E S S + S T O R A G E / M E C H . A S S O C I A T E D W / B U S I N E S S : (4 , 5 2 9 / 1 0 0 + ( 6 7 3 / 3 0 0 ) = 4 9 49 / 2 = 2 5 M E N , 2 5 W O M E N RE Q ' D . TO T A L W . C . = 1 / 2 5 2 TO T A L L A V . = 1 / 4 0 2 RE Q ' D . PR O V I D E D TO T A L R E Q ' D M E N W . C . 4 8 TO T A L R E Q ' D W O M E N W . C . 4 6 TO T A L R E Q ' D L A V . 5 9 TO T A L U N I S E X R . R . 1 1 DR I N K I N G F O U N T A I N 1 * SE R V I C E S I N K 1 1 * DRIN K I N G W A T E R T O B E P R O V I D E D B Y O W N E R I N L I E U O F D R I N K I N G F O U N T A I N . 1 AN C I L L A R Y S P A C E S S E R V I N G A S S E M B L Y , B U S I N E S S , O R A C C E S S O R Y S T O R A G E A R E A S , AN D A R E N O T I N C L U D E D I N A R E A D E T E R M I N I N G O C C . L O A D C A L C U L A T I O N S ( I B C 1 0 0 4 . 1 ) . SM O K E - R E S I S T A N T C O N S T R U C T I O N P A R T I T I O N E X T E N D I N G F R O M F L O O R T O U N D E R S I D E OF R O O F / C E I L I N G A S S E M B L Y P E R I B C S E C T I O N 5 0 8 . 2 . 2 . 1 . EX I S T I N G F U L L - H E I G H T M A S O N R Y W A L L BUILDING NOTES:- ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2008 INDIANA BUILDING CODEWITH AMENDMENTS (2006 INTERNATIONAL BUILDING CODE WITH INDIANA REVISIONS).- BUILDING EQUIPPED WITH A SPRINKLER SYSTEM.- BUILDING EQUIPPED WITH A FIRE ALARM SYSTEM THAT SHALL BE IN ACCORDANCE WITHSECTION 907 IBC (675 IAC 13-2.5).