HomeMy WebLinkAbout087 IMPA Bid Set 3 - H601.pdfTAG ACCU-1, 4 ACCU-2 ACCU-3 ACCU-5 ~ MANUFA�TURER BRYANT BRYANT BRYANT BRYANT z � MODEL 127A 127A 127A 127A MIN SEER 17 17 17 17 WEIGHT 373 243 373 243 V-P H-HZ 2�8-1-60 208-1-60 208-1-60 208-1-60 w MCA 3Q.1 22.1 30.1 27.8 w MOCP 50 35 50 40 DIS� EC EC EC E� EVAPORAT�R COIL 5 3 5 4 w N4MINAL T4NS N � STAGES 2 2 2 2 R E F R I G E RAN T R-410A R-41 QA R-41 QA R-410A NOTES 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4, 5 1, 2, 3, 4 1) PROVIDE HARD SHUT-OFF TXV, FILTER-DRYER, AND SIGHT GLASS FOR EACH CIRCUIT. w 2) MATCH CAPAGITY LISTED IN THIS SCHEDULE WITH THE EVAPORATOR CaIL. � 0 3) PROVIDE LOW AMBIENT PRESSURE SWITCH, GRANK-CASE HEATER AND START ASSIST. z 4) SUPPORTS THERMIDISTAT C4NTR4L F4R DEHUMIDIFICATION. SCROLL C4MPRESS4R. 5) PROVIDE LOW AMBIENT CONTROLS. TAG DSFCU-1 / DSHP-1 MANUFACTURER CARRIER INDaOR M4DEL RAV-SP360UT-UL � z OUTDOOR MODEL RAV-SP360AT2-UL � N4MINAL TON �C40LING) � N4MINAL MBH (HEATING} 36 WEIGHT (LBS) 65 INDOOR / 230 OUTD04R V-PH-HZ 208-1-60 w M CA 24 w MaCP 40 DISG EC NOTES 1 1. OUTDOOR CONDENSING UNIT . PROVIDE LOW AMBIENT OPERATI4N OF CONDENSING UNIT TO AT LEAST -10 DEGREES. c� PROVIDE WITH MFR WALL MOUNTED WIRELESS THERMOSTAT. � C04LING BTUH IS AT 95 DEGREE AMBIENT. MCA AND MOGP ARE 0 FOR BOTH INDOOR AND OUTDOOR UNITS. PROVIDE INSULATED z REFRIGERANT LINE SET; PR4VIDE HARD SHUT-OFF TXV, FILTER-DRYER, AND SIGHT GLASS FOR EACH CIRCUIT; SIZE PIPING PER MFR RECOMMENDATIONS. PROVIDE GRANKGASE HEATER & LONG LINE KIT. TAG LV R-1 MANUFACTURER GREENHECK MaDEL NUMBER EDJ-401 WIDTH 56 � HEIGHT 24 Z � F RE E AREA �sqft) 4.2 SERVES DRYER ROOM AI RFL�W CFM 745 MAX ESP �in wg} 0.03" N�TES 1, 2, 3 1. EXTRUDED ALUMI NUM LOUVER. KYNAR FI NISH SELECTED BY ARCHITECT. REMOVABLE ALUMINUM w I NSECT SCREEN. H 0 2. LDUVER T� FIT WIDTH aF EXISTING WINDOW Z aPENI NG; FI ELD VERI FY ACTUAL WI DTH. 3. aTHER MANUFACTURERS: RUSKIN, LOUVERS AND DAMPERS. TAG E H-B 1 MANUFACTURER GREENHECK � DESIGN RELIEF z � M4DEL NUMBER GRSR CFM 375 THROAT DIMENSIONS 12"� N�TES 1,2,3,4 1) 16" RaOF CURB (FOR SLOPED ROOF); BIRD AND INSECT SCREEN w 2) 3/4" THICK FIBER FREE HOOD INSULATION � � 3) MOT4RIZED DAMPER BY T�C. z 4) MOTORIZED DAMPER TO OPEN (FULLY) ON CALL FROM EXHAUST FAN. 5} INSTALL FAN ON REAR 4F BUILDING. TAG RTU-1 A,1 B RTU-2A, 2B RTU-3 � MANUFACTURER BRYANT BRYANT BRYANT z � M O D E L 580J 5$OJ 5$OJ NOMINAL TONS 17.5 12.5 17.5 W E I G HT 2500 2500 2500 V-PH-HZ 208-3-60 208-3-60 208-3-6Q w # COMPRESSORS /# CIRCUITS 2/ 2(MIN) 2/ 2 2/ 2(MIN} w POWER M�A / MOCP 1 Q0.5 / 125 6$.2 /$0 100.5 / 125 FURNISH DISC / STARTER EC / MFR EC / MFR EC / MFR TOTAL C FM 5700 4200 600Q O/A CFM 11 �0 1300 1�50 Q M I N I M U M O/A C FM S ETTI N G 275 550 35� � EXTERNAL STATIC (SUPPLY FAN) 1.2" 1.2" 1.0" EXTERNAL STATIC (EXHAUST FAN} 0.75" 1.0" 1.0" TOTAL M B H 197 153. 7 200 � Z SENSIBLE MBH 132.5 113.5 137.5 J � EADB 76 82.0 76 0 U EAWB 65 6$.0 65 � w GAS INPUT tM6H) 80% EFF {MIN) 400 250 400 _ NOTES 1, 2, 3, 4 1, 2, 3, 5 1, 2, 3 1. INSULATED 18" R04F CURB. PROVIDE CONDENSATE PAN OVERFL4W SWITCH WIRED TO SHUT UNIT DOWN. COMPLY WITH ASHRAE 90.1-2007 EER / SEER. OUTDOOR AIR DAMPER MUST CLOSE WHEN UNIT IS OFF OR IN NIGHT SETBACK aR MORNING WARM UP. SINGLE POINT ELECTRICAL P4WER GONNECTION. UNIT TO HAVE CO2 SENSOR, WITH DEMAND C4NTR4L VENTILATION, AND HUMIDITY SENSOR IN RETURN DUCT. UNITS TO HAVE HINGED ACCESS PANELS. COORDINATE SMOKE DETECTORS IN BOTH SUPPLY AND RETURN AIR DUCTS WITH ELECTRICAL CONTRACTOR. w 2. HEAT EXCHANGER: ALUMINIZED STEEL: RTU-1A 1 B& 3. STAINLESS STEEL: RTU-2A 2B � , , � 3. ENTHALPY ECONOMIZER WITH EXHAUST FAN (FORWARD CURVED FAN). MODULATING OR z MULTI-STAGE t2 STAGES) GAS HEAT. PR4VIDE LOW AMBIENT C40LING 4PERATION TO 0 DEG F. CO2 SENS4R, WITH DEMAND C4NTROL VENTILATION, C4NTROL 4F OA DAMPER. PR4VIDE HUMIDISTAT AND CO2 SENSORS IN RETURN AIR QUCT. UNIT T4 HAVE A MINIMUM OF 2 COOLING STAGES. AT LEAST 1 COMPRESSOR TO BE DIGITAL SCROLL COMPRESSOR TYPE. 4. RTU-1A AND RTU-1 B TO BE �ONTR4LLED BY AVERAGING THERMOSTATS. RTU-1A TO BE LEAD RTU AND RTU-1 B TO BE LAG RTU. 5. RTU-2A TO BE LEAD RTU AND RTU-2B TO BE LAG RTU. 1) 7-DAY PROGRAMMABLE THERMOSTAT �4NTRaLS STAGES OF COMPRESSOR AND GAS HEAT TO w MAINTAIN 4CCUPIED OR UNOCCUPIED SETPOINTS. FAN SHALL RUN C4NTINUOUSLY DURING Z 4CCUPIED CYCLE, INTERMITTENT DURING UNOCCUPIED CYCLE. DURING OCGUPIED CYGLE, w OUTDOOR AIR DAMPER SHALL BE OPEN TO MINIMUM POSITION TO PROVIDE SCHEDULED OUTDOOR � AIR. PROVIDE ENTHALPY CONTROLLED ECONOMIZER CYCLE WHERE NOTED Ta MODULATE � TD R AIR AND RET RN AIR DAMPER . TD R AIR DAMPER HALL BE H T D RIN � OU 00 U S OU 04 S S U U G UN4CCUPIED CYGLE. CONTROL 4PERAT14N OF EXHAUST FAN(S) TO MAINTAIN BUILDING PRESSURE; PROVIDE BUILDING PRESSURE SENSORS. TAG F-1 F-2 F-3 F-4 F-5 MANUFACTURER BRYANT BRYANT BRYANT BRYANT BRYANT � M O D E L 925TA 925TA 925TA 925TA 925TA z � NOMINAL TONS 5.0 3.0 5.0 5.fl 4.fl W E I G HT 205 205 2fl5 205 205 AREA SERVED NORTH BREAK �ORE BUFFET S4UTH OFFICE ROOM OFFICE V-P H- HZ 120-1-60 120-1-60 120-1-60 120-1-60 120-1-60 H P 1 3/4 1 1 3/4 U w MOCP 20 15 2Q 20 15 w STARTER BY M FR M FR M FR M FR M FR DISC BY EC EC EC EC EC TOTAL CFM 1950 1200 1750 1750 1400 Q 4/A CFM 230 155 240 350 100 � EXTERNAL STATIC 0.5" 0.5" Q.5" 0.5" 0.5" Q GAS INPUT (MBH) 120 60 100 100 60 = CAPAC ITY (M B H) 117 58 98 98 58 NOTES 1,2 1,2 1,2 1,2 1,2 1) PROVIDE GASED DX COIL. SELE�T EVAPORATOR COIL TO PROVIDE CAPA�ITY OF � SCHEDULED AIR C44LED CONDENSING UNIT. PROVIDE G4NDENSATE 4VERFL4W � SENSOR, WIRE TO SHUT UNIT DOWN WHEN HIGH LEVEL IS SENSED. MULTI-STAGE 4 FURNACE/EVAPORATOR MQTOR. NEOPRENE ISOLAT4RS F4R FLOOR M�UNTING. Z CONCENTRIC VENT KIT. PROVIDE 7 DAY PROGRAMABLE THERMIDISTAT. 2} TOTAL CFM IS NOMINAL AIRFLOW; REFER TO DRAWING F4R ACTUAL SYSTEM AIRFLOW. U 7-DAY PROGRAMMABLE THERMIDISTAT TO CONTROL CONDENSING UNIT AND FURNACE Z TO MAINTAIN OCCUPIED OR UNOCCUPIED SETPOINTS. FAN SHALL RUN CONTINUOUSLY w � DURING OCCUPIED PERIODS AND INTERMITTENT DURING UN4CCUPIEQ PERIODS. w� THERMIDISTAT COMBINED THERMOSTATAND HUMIDISTAT . DEHUMIDIFICATION CYCLE. � � ) TAG NOM SIZE NECK MAX CFM "WG Pt MAX NC TYPE MFR M4DEL FINISH NOTES D1 24 x 24 6"� 100 5Q9 0.024 <15 STEEL ADJUSTABLE 4-CONE DIFFUSER PRICE SCDA BY AR�H 2 D2 24 x 24 8"� 210 602 0.038 <15 STEEL ADJUSTABLE 4-CONE DIFFUSER PRICE SCDA BY ARCH 2 D3 24 x 24 10"� 365 669 0.054 16 STEEL ADJUSTABLE 4-CONE DIFFUSER PRICE SCDA BY ARCH 2 D4 24 x 24 12"� 600 765 0.082 22 STEEL ADJUSTABLE 4-CONE DIFFUSER PRICE SCDA BY ARCH 2 D5 12 x 12 6"� 100 509 0.03Q <15 STEEL ADJUSTABLE 4-CONE DIFFUSER PRICE SCDA BY ARCH 2 D6 6"� 6"� 20 NA NA NA ROUND AUDITORIUM STAIR RISER DIFFUSER SEIHO JRC-6 6 D7 9-1/8 x 9-1/8 6 x 6 125 500 0.135 23 ALUM. SQUARE ADJUSTABLE DIFFUSER PRICE LCMD-4A BY ARCH 2,3 D$ 11-1/8 x 11-1/8 $ x$ 222 500 0.135 26 ALUM. SQUARE ADJUSTABLE DIFFUSER PRICE LCMD-4A BY AR�H 2,3 � D9 13-1/8 x 13-1/8 10 x 10 350 500 0.135 28 ALUM. SQUARE ADJUSTABLE DIFFUSER PRICE LCMD-4A BY ARCH 2,3 � � D10 15-1/8 x 15-1/8 12 x 12 500 500 0.135 30 ALUM. SQUARE ADJUSTABLE DIFFUSER PRICE LCMD-4A BY ARCH 2,3 � � G1 6 x 6 6 x 6 110 600 0.063 18 DOUBLE DEFL, 1/2" BLADE SPACE PRICE 520 BY ARCH 2,3 G2 20 x 6 20 x 6 420 605 0.025 18 DOUBLE DEFL, 1/2" BLADE SPACE PRICE 520 BY ARCH 2,3 G3 24 x 36 24 x 36 1400 12 DOUBLE DEFL, 1/2" BLADE SPACE PRICE 520 BY ARCH 2,3,7 G4 48 x 24 48 x 24 1400 12 DOUBLE DEFL, 1/2" BLADE SPACE PRICE 520 BY ARCH 2,3,7 G5 36 x 24 36 x 24 1400 12 DOUBLE DEFL, 1/2" BLADE SPACE PRICE 520 BY ARCH 2,3,7 G5 4$ x 6 48 x 6 510 15 DOUBLE DEFL, 1/2" BLADE SPACE PRICE LBPH 15B BY ARCH S1 48" L4NG 10"� 300 550 0.025 20 6 FT LONG TWO-1" SLOTS DIFFUSER PRICE SDS-100 BY ARCH 5 S2 48" LONG 12"� 432 550 0.037 21 6 FT LONG THREE-1" SLOTS DIFFUSER PRICE SDS-100 BY ARCH 5 S3 48" L4NG 8"� 200 5$5 0.024 19 4 FT LONG THREE-1" SLaTS DIFFUSER PRICE SDS-100 BY ARCH 5 R1 24 x 12 $00 444 0.012 <15 1/2"X1 /2"X1 " ALUM. EGGCRATE PRICE 81 BY ARCH 1 R2 24 x 24 1600 522 0.017 <15 1/2"X1 /2"X1 " ALUM. EGGCRATE PRICE 81 BY ARCH 1 R3 36 x 36 2700 225 < 0.015 <15 3/4" , 45° ANGLE , SINGLE DEFLECT BLADES PRICE 635 BY ARCH 1 w E1 6 x 6 100 524 0.017 19 3/4" , 45° ANGLE , SINGLE DEFLECT BLADES PRICE 635 BY ARCH 3 � w E2 12 x 12 375 427 0.411 30 3/4" , 45° ANGLE , SINGLE DEFLECT BLADES PRICE 635 BY ARCH 3 � E3 24 x 12 750 413 0.411 19 3/4" , 45° ANGLE , SINGLE DEFLECT BLADES PRICE 635 BY AR�H 3 E4 36 x 20 2500 440 0.012 20 3/4" , 45° ANGLE , SINGLE DEFLECT BLADES PRICE 635 BY ARCH 3 E5 18 x 12 500 400 20 3/4" , 45° ANGLE , SINGLE DEFLECT BLADES PRICE 635 BY ARCH 3 1. FIRMLY AND DIRECTLY ATTACH DUCT TRANSITION TO EGGCRATE GRILLE. 2. PROVIDE PLASTER FRAME WITH HIDDEN FASTENERS IN DRYWALL CEILINGS AND WALLS. SEE ARCHITEGTURAL REFLECTED CEILING PLAN F4R LOCATIONS AND SUBSEQUENT QUANTITIES. PRaVIDE COLOR SELECTION BY ARCHITE�T FROM MFR'S LIST OF STANDARD COLORS. 3. PROVIDE FRAMED AND DRYWALL CEILING 4PENING N4 MORE THAN 1/2" LARGER THAN NECK SIZE. PROVIDE SQUARE T4 ROUND TRANSITI4NS WHERE REQUIRED T4 � CON N ECT TO DUCTWORK. w p 4. PROVIDE BALANCING DAMPER AS PART OF AIR INLET/aUTLET ASSEMBLY z 5. PROVIDE EXTRUDED ALUMINUM BaRDER MITERED END FLANGES FOR THE CONTINUOUS LENGTH, INTEGRAL ADJUSTABLE CLAMSHELL ALUMINUM PATTER CaNTR4LLERS, INTERNALLY LINED SUPPLY AIR PLENUM, AND FINISH B12 WHITE POWDER �DATED FINISH. 6. PROVIDE ADJUSTABLE, LOW OBTRUSIVE, LOW AIR VELOCITY WALL DIFFUSERS. 6" DIAMETER DUCT WITH DUCT SCREW DUCT FASTENERS AND ESCUTCHEON PLATE WITH POSITIVE SEALING GASKET BODY CONNECTION TO DUCT. STANDARD �LEAR ANODIZED ALUMINUM FINISH. 7. INSTALL GRILLE WITH BOTTOM 4F BORDER AT 12" ABOVE FINISHED FL40R. EWH-1, 2, 3, EBH-1A,1 B EBH-2A,2B EBH-3A,3B EBH-5, 6 RCP-1A,B,C EUH-1, 2 TAG 4 E B H-4 R�P-2A, B � z MANUFACTURER MARKEL MARKEL MARKEL MARKEL MARKEL MARKEL MARKEL � M4DEL 3320 SERIES DBSL DBSL DBSL DBSL CP SERIES 5100 SERIES V-P H- HZ 208-1-60 208-1-60 208-1-60 2�8-1-60 208-1-60 208-1-60 208-1-60 v H EAT KW 4.0 2.0 2.5 1.25 1.5Q 750 WATTS (EA) 4.0 w J w LENGTH / SIZE N/A 8 10 5 6 48" X 24" N/A DISC4NNECT MFR MFR MFR MFR MFR MFR MFR NOTES 1 3, 6 3, 6 3, 6 3, 5, 6 4 2 1. INTEGRAL THERMOSTAT. RECESSED MOUNTING ACCESSORY. FR4NT INLET AND DISCHARGE WITH ARCHITECTURAL BAR GRILLE. COLOR SELECTED BY ARCHITECT. w 2. INTEGRAL THERMOSTAT. PR4VIDE CEILING MOUNT KIT. � 0 3. HEATING DEVICES IN PREFUNCTION VESTIBULE CONTROLLED BY SINGLE THERMOSTAT. CUSTOM COL4R BY ARCH. z 4. RADIANT CEILING PANELS TO BE CONTROLED BY WALL THERMOSTAT. PR4VIDE MOUNTING FOR LAY-IN CEILING. 5. INTEGRAL THERMOSTAT. STAT TO BE SET TO 60° F. CUSTOM COLOR BY ARCH. 6. PROVIDE PEDESTAL MaUNTS FaR BASEB4ARD HEATERS. TAG E F-1 E F-2 E F-3 E F-4 MANUFA�TURER GREENHECK GREENHECK GREENHECK GREENHECK � z � M4DEL CSP-A51 � GB-091 GB-101 GB-091 WEIGHT 75 75 75 75 AREA SERVED 4FFICE COFFEE BAR PREFUNCTION STORAGE RESTROaMS RESTRaOMS V-P H- HZ 120-1-60 120-1-60 12Q-1-60 12Q-1-60 U w H P 217 WATTS 1/4 1/4 1/4 J W DISGONNECT MFR MFR MFR MFR z CFM 375 500 900 500 Q � EXTERNAL STATIC PRESSURE 0.375" 0.375" 0.375" 0.375" NOTES 1,2 1,2,3 1,2 1,2 w 1. FAN TO RUN CONTINUOUSLY. ON/OFF AT CIRCUIT BREAKER. � � 2. PROVIDE INSULATED 1$" HIGH ROOF CURB. BACK DRAFT DAMPER. z 3. G.0 TO PROVIDE TIE-OFF FOR SERVICE.