HomeMy WebLinkAbout092 IMPA Bid Set 3 - P201.pdfGENERAL NaTES:
1. SEE SHEET P001 FOR PLUMBING
GENERAL PLAN NOTES.
2. PROVIDE DRY PIPE FIRE SPRINKLER
SYSTEM IN ATTIG AREA OF EXISTING
BUILDING. ATTIC AREA IS A
NON-HEATED SPACE WITH INSULATION
AT TOP OF CEILING SPACE, NOT
ATTACHED TO ROOF DECK.
PLAN N�TES:
1 1%2" GAS UP. SEE SHEET P203 FOR
CONTINUATI�N.
2 1" GAS UP. SEE SHEET P203 FOR
CONTINUATION.
3 3" CW, 1%2" RO, AND FIRE SPRINKLER LINE
UP AND PIPE ABOVE CEILING OF LOBBY
108.
4 3" CW, 1" RO, AND FIRE SPRINKLER LINE
DOWN AND PIPE ABOVE CEILING OF HALL
111.
5 2" CW DROP IN WALL AND BRANCH TO
SUPPLY FIXTURES.
6 PROVIDE WATER HAMMER ARRESTER
TYPE {WHA-4) PRIflR TO THE LAST FLUSH
VALVE. PROVIDE ACCESS PANEL IN WALL
FOR MAINTENANCE.
7 PROVIDE WATER HAMMER ARRESTER
TYPE {WHA-1 } PRI�R TO THE LAST FLUSH
VALVE. PROVIDE ACCESS PANEL IN WALL
FOR MAINTENANCE.
8 GAS REGULATOR RATED FOR 2.0 PSI
DOWN TO 10" W.C. PROVIDE VENT TO
ATMOSPHERE AS REQUIRED.
9 1" GAS @ 10" W.C. FOR CONNECTION TO
FURNACE.
�� 3/4" GAS @ 10" W.C. FOR CONNECTION TO
FURNACE.
11 1" GAS @'10" W.C. FOR CONNECTI�N TO
WATER HEATER.
12 AIR COMPRESSOR SIZE SHALL BE
QETERMINED BY THE FIRE SPRINKLER
CONTRACTOR FOR THE DRY SPRINKLER
SYSTEM FOR THE ATTIC AREA.
13 �2' RO WITH IN-LINE DUAL CHECK VALVE
LIKE WILKINS MODEL 700-XL, DROP IN
WALL AND STUBBED OUT AT 6" ABOVE
COUNTERTOP FOR CONNECTION TD
JUICE MACHINE AND WATER DISPENSER.
SEE ARCHITE�TURAL ELEVATIONS FOR
EXACT LOCATION.
14 1" GAS @'I 0" W.C.
15 1�/4" GAS @ 10" W.C.
16 2�� GAS @ 10" W.C.
17 %2' RO WITH IN-LINE DUAL CHECK VALVE
LIKE WILKINS MODEL 700-XL, DROP IN
WALL AND STUBBED OUT AT 6" ABOVE
COUNTERTOP FOR CONNECTION TO
COFFEE MACHINE. SEE ARCHITECTURAL
ELEVATIONS FOR EXACT LOCATION.
1$ 2" WASTE STAN DPI PE WITH P-TRAP
CONNECTED TO (CDB-1 } IN WALL AND
STUBBED UP TO 72" A.F.F. TO RECEIVE
CONDENSATE DRAIN FROM (RTU'S}, SEE
'H' SERIES DRAWINGS FOR
COORDINATION.