Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.2 REFLECTED CEILING_ELEC-DATA PLANS.pdf
Project Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Management: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Drawn By Checked ByPrint Date Revisions: 76 0 3 R D A V E N U E S . W . , S U I T E 1 1 0 & S U I T E 1 1 2 PE D C O R S Q U A R E B U I L D I N G 2 LI N D A M O O D - B E L L L E A R N I N G P R O C E S S E S & S U I T E 1 1 2 N A1.2 REFLECTED CEILING/ELEC- DATA PLANS PEDCOR DESIGN GROUP, LLC 9/19/14 CONSTRUCTION DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2014, JAMES R. STUTZMAN, AIA, CARMEL. 9/19/14 STATE RELEASE SET MC AJR KEY PLAN SCALE: N.T.S. FIRST FLOOR CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. RELOCATE OR ADD LIFE SAFETY ITEMS AS REQUIRED FOR NEW WALL LAYOUT. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: EXISTING EMERGENCY LIGHT FIXTURE W/BATTERY PACK TO REMAIN. 5. 6. 4. 1. CP63.RELOCATE OR ADD FIRE SPRINKLERS AS REQUIRED FOR NEW WALL LAYOUT. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. NEW OR RELOCATED DOWNLIGHT FIXTURE TO MATCH EXISTING. N INDICATION DUAL-LITE TO MATCH EXISTING. NEW OR RELOCATED CEILING MOUNTED EXIT LIGHT W/ DIRECTION DUAL-LITE TO REMAIN. EXISTING CEILING MOUNTED EXIT LIGHT W/ DIRECTION INDICATION N D 3 2.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. CEILING HEIGHT IS 10'-0" A.F.F. UNLESS NOTED OTHERWISE. CEILING PLAN NOTES: CP1 CP3 INSTALL NEW TILE AND GRID AS SHOWN. REUSE DEMO'D TILE AS MUCH AS POSSIBLE. PROVIDE NEW SWITCH TO CONTROL LIGHTING. CP4 LIGHT FIXTURES TO BE CONTROLLED BY AN OCCUPANCY SENSOR. HVAC CONTRACTOR TO RECONFIGURE HVAC DISTRIBUTION FROM THE EXISTING HEAT PUMP UNITS AS NEEDED FOR THE NEW LAYOUT. CONSIDER DEDICATING BOTH EXISTING UNITS FOR SUITE 110 AND PROVIDING A NEW SYSTEM FOR THE ADJACENT SUITE 112. THREE-WAY SWITCH. DIMMER SWITCH. TWO WAY SWITCH. DENOTES NEW SWITCH LOCATION. EXISTING 2 X 4 LAY-IN GRID SUSPENSION SYSTEM. EXISTING. REFLECTED CEILING LEGEND: NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE TO MATCH EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN. CP5 REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. G.C. TO VERIFY EXISTING GRID LAYOUT AND CONDITION. RE-USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. ALL EXISTING AND REUSED FIXTURES TO BE CLEANED AND RELAMPED UPON COMPLETION OF CONSTRUCTION. ALL LAMPS TO BE 3500K COLOR TEMPERATURES. EACH ROOM TO HAVE INDIVIDUAL LIGHTING CONTROLS LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE CONTROLS IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 10. 9. 8. 7. LOCATE NEW AND RELOCATED SMOKE DETECTORS DUE TO NEW WALL AND/OR LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. HALLWAY LIGHTS TO BE TIED INTO THE EXISTING HALLWAY LIGHT CIRCUIT. CP7 N NEW OR RELOCATED EMERGENCY LIGHT FIXTURE W/BATTERY PACK TO MATCH EXISTING.N NEW OR RELOCATED LAY-IN GRID SUSPENSION SYSTEM TO MATCH EXISTING. CP2 FLUORESCENT DOWNLIGHTS WITH AN "N" OR FLUORESCENT TROFFERS WITH AN "X" TO BE NEW OR RELOCATED LIGHT FIXTURES TO MATCH EXISTING. REPLACE LAMPS WITH MATCHING 3500K COLOR TEMPERATURES. CP8 PROVIDE NEW OR RELOCATED BATTERY BACKUP NIGHT LIGHT.CP9 REWIRE LIGHTS TO TIE FIXTURES IN THIS ROOM TO THE LIGHT SWITCH.CP10 PROVIDE VENT DUCTED DIRECTLY OUTSIDE. CONTROL VENT FAN WITH OCCUPANCY SENSOR.CP11 EXISTING 2' X 2' FLUORESCENT FIXTURE TO REMAIN. EXISTING. NEW OR RELOCATED 2' X 2' FLUORESCENT FIXTURE TO MATCH 3 NN N N N N 3 3 3 DN N N N N N N N N 3N CP9 CP1 CP2 CP6 CP7 CP5 CP6CP2 CP3 CP5 CP6 CP2 CP4 CP5 CP6 CP2 CP4 CP1 CP1 CP5 CP7 CP2 CP6 CP3 CP3 CP5 CP7 CP2 CP6 CP1 CP1 CP1 CP1 CP1 CP3 CP5 CP1 CP2 CP3 CP3 CP5 CP6CP2CP4 CP1 CP5 CP6CP2CP4 CP1 CP9 CP9 CP9 CP9 CP3 CP5CP2 CP8 CP6 N CP1 CP2 CP6 CP7CP6CP7 CP3 CP10 CP5 CP6 CP2 CP4 CP1 CP5 CP6CP2CP4 CP5 CP6CP2CP4 CP5 CP6CP2CP4 CP5 CP6CP2CP4 CP5 CP6CP2 CP2 CP4 CP5 CP6 CP11 B B KITCHEN/ STAFF AREA 116 INSTRUCTION ROOM 108 STUDENT FRIG. STUDENT STORAGE CUBES COPY/WORK AREA 113 STUDENT REST ROOM 118 LOBBY 103 PRIVATE TESTING ROOM 111 SHARED OFFICE 107 MEETING ROOM 104 OFFICE 105 OFFICE 106 PRIVATE TESTING ROOM 110 OFFICE 112 STORAGE/ IT CLOSET 117 FEC +44" +44" +44" +44" +44" +44"+44"N N N N N N N N +44"+44" N N N N N N N N N N N N N N N N N N N N NN N N N N N N FEC N N N EP1 EP2 EP3 OFFICE A1 120 OFFICE B 122 BREAK ROOM 124 OFFICE C 123 OFFICE A2 121 EP1 N N N N N N EP1 EP2 ENTRY 100 HALLWAY 102 HALLWAY 101 HALL 109 HALL 114 HALL 115 HALL 119 CLOSET 122B CLOSET 122A CLOSET 123B CLOSET 123A EP4 EP5 EP6 EP6 EP6 EP7 EP3 EP1 EP1 EP1 EP3 EP1 EP3EP1EP3 EP1 EP2 EP1 EP2 EP3 EP1 EP1 EP1 EP1 EP2 EP3 EP2 EP3 EP2 EP3 EP2 EP3EP1EP3 GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF TO CENTER OF DEVICE UNLESS NOTED OTHERWISE. 7. 8. 6. 5. 4. 3. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. 9.PEDCOR IT TO PROVIDE PHONE AND INTERNET SERVICE IN SUITE 112. PROVIDE ELECTRICAL SUPPLY AS SHOWN WITH AN "N" ON THE PLAN.EP1 PROVIDE DATA OUTLETS W/ CABLING AS SHOWN WITH AN "N" ON THE PLAN. PEDCOR IT IS TO PROVIDE WIRING AND FACEPLATES FOR PHONE AND INTERNET SERVICE THAT WILL BE PROVIDED BY THE TENANT. EP2 ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. DUPLEX WALL OUTLET. DEDICATED CIRCUIT OUTLET.D ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44" N HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. DENOTES NEW OUTLET LOCATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. ALL FURNITURE , FIXTURES, AND EQUIPMENT TO BE SUPPLIED BY TENANT UNLESS NOTED OTHERWISE. EP3 COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP4 REFRIGERATORS PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATORS. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP5 PROVIDE ELECTRICAL FOR KEY CARD ACCESS.EP6 CHANGE ELECTRICAL OUTLET TO JUNCTION BOX FOR FURNITURE SYSTEM POWER WHIP WITH TWO (2) CIRCUITS. EP7 10.ALTERNATE: PROVIDE PRICING TO INSTALL PHONE AND DATA WIRING FROM IT CLOSET 117 TO PHONE/DATA OUTLETS IN TENANT SUITE 110 SPACE. N N SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SCALE: 1/8" = 1'-0" 2 ELECTRICAL/DATA PLAN A1.2