HomeMy WebLinkAboutEnvelope ComCheck 09_16_14.pdfCOMcheck Software Version 3.9.4 Envelope Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Giant Eagle Market District #6550 Construction Site: Carmel, IN Owner/Agent: Giant Eagle Incorporated 254 Kappa Drive Pittsburgh, PA Section 2: General Information Building Location (for weather data): Carmel, Indiana Climate Zone: 5a Building Space Conditioning Type(s): Nonresidential Vertical Glazing / Wall Area Pct.: 11% Buildina Tv�e Retail Floor Area 122137 Designer/Contractor: William E. Hulsey, P.E. McHenry & Associates, Inc. 25001 Emery Road Suite #200 Warrensville Heights, OH 44128 216.292.4696 mai I@mche n ryassociates. com �'��q ti•$G�5 T�'Qcs �,�.�: �2� ¢ � �� �� AR11400Q24 �_ �� STATE OF �� �'� �N� I ANA �.`: h_.e_ �c _♦ � w • • � ' ' � � � / Envelope PASSES: Design 2% better than code Climate-Specific Requirements: Component Name/Description Roof 1: Insulation Entirely Above Deck � Skylight 1: Metal Frame with Thermal Break:Double Pane, Perf. Type: Other testing/cert. Product ID: , SHGC 0.42 (c) Exterior Wall 1: Other Steel Framed Wall (b) �ndow 1: Metal Frame:Double Pane, Perf. Type: Other testing/cert. Product ID: , SHGC 0.39 (c) Door 1: Insulated Metal, Swinging Gross Area or Perimeter � 122137 1221 39870 4209 150 Cavity Cont. Proposed Budget R-Value R-Value U-Factor U-Factor�a� 20.0 0.048 0.048 --- 0.740 0.690 --- 0.064 0.064 --- 0.250 0.550 --- 0.500 0.700 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors, (c) Fenestrations product performance must be certfied in accordance with NFRC and requires supporting documentation. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 90.1 (2007) Standard requirements in C�Mcher.k Version 3.9.4 and to comply with the mandatory require snts in the �equirements Checklist. �1�� �[ . ��'�1� A �• � - -- 91r �/ � Project Title: Giant Eagle Market District #6550 Report date: 09/16114 Data filename: Q:Wetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim COMcheck R-20.cck Page 1 of 2 Name - Title Signature Date Project Title: Giant Eagle Market District #6550 Report date: 09/16/14 Data filename: Q:Wetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim COMcheck R-20.cck Page 2 of 2 COMcheck Software Version 3.9.4 Inspection Checklist Energy Code: 90.1 (2007) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Giant Eagle Market District #6550 Report date: 09/16/1 Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 1 of 7 COMcheck R-20.cck (�flFf7j Plan Reniew Cvrnplles? I Cvmmen#slAssumptions Standard 4.2.2 ; Plans and/or specifications provide all [PRl]� I information with which compliance ; can be deYermined for the building ; envelope and document where � exceptions to the standard are ; claimed. Additional Comments/Assumptions: ;❑Complies ;❑Does Not ;❑Not Observable ;❑Not Applicable Requirement will be met. Location on plans/spec: A101-A, A106, A400 series 1 High Impa�t (Tier 1) 2 Medium Impact (Tier 2) 3 Low 1�paet (Tier 3j Project Giant Eagle Market District #6550 Report date: 09/16/1 Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 2 of 7 COMcheck R-20.cck '� #'� Faoting � Foundation & iteq.lD Inspectivn 5.5.3.3 Below-grade wall insulation R- [FOl]i value. 5.5.3.5 Slab edge insulation R-value. [F03]1 5.5.3.5 Slab edge insulation [F05]1 depthllength. 5.8.1.7.3 Insulation in contact with the [F07]1 ground has <=0.3% water absorption rate per ASTM C272. Additional Comments/Assumptions: Plans Veriffed I Field Verified �pmplies? Cvmmer+tslAss�mptions Va[ue � Va�ue R- __ R- ❑ComplieS ; See the Envelope Assemblies R- ❑ Unheated ❑ Heated ft �Does Not ; table for values. ;❑Not Observable ; ;�Not Applicable ; R- ❑Compiie5 See the EnvelopeAssemblies ❑ Unheated �Does Not table for values. ❑ Heated ;❑Not Observable ;❑Not Applicable ft OCOmplfes See the Envelope Assemblies ❑DOeS Not table forvalues. ;❑Not Observable ;�Not Applicable �Complies Requirement will be met. ❑L�aes Not ❑iVot Observable Location on plans/spec: ❑Nat Applicable 072100 � 1 I High Impact (Tier 1) ��Medium fmpact (Tier 2) 3 Low Impa�t (Tier 3) 1 Project Giant Eagle Market District #6550 Report date: 09/16/1 Data Q:�Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 3 of 7 COMcheck R-20.cck Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 5.4.3.2 Factory-built fenestration and Fenestration! Fenestration ❑Complies Requirement will be met. [FR1]3 doors are labeled as meeting air _ cfm/ftz _ cfm/ftz ❑Does Not leakage requirements. Doors Doors ❑Not Observable cfm/ftz cfm/ftz ❑Not Applicable 5.4.3.4 Vestibules are installed where ❑Complies Exception: Requirement [FR4]3 building entrances separate ❑Does Not does not apply. conditioned space from the exterior, and meet exterior ❑Not Observable envelope requirements. Doors ❑Not Applicable have self-closing devices, and are >=7 ft apart. 5.5.4.3a Vertical fenestration U-Factor. � U- U- ❑Complies See the Envelope Assemblies [FR8]1 ❑Does Not table forvalues. ❑Not Observable ❑Not Applicable 5.5.4.3b Skylight fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies [FR9]1 ❑Does Not table forvalues. ❑Not Observable ❑Not Applicable 5.5.4.4.1 Vertical fenestration SHGC value. SHGC: SHGC: ❑Complies see the Envelope assemblies [FR10]1 ❑Does Not table forvalues. ❑Not Observable ❑Not Applicable 5.5.4.4.2 Skylight SHGC value, SHGC: SHGC: ❑Complies See the Envelope Assemblies [FR11]1 ❑Does Not table forvalues. ❑Not Observable ❑Not Applicable 5.8.2.1, Fenestration products rated in ❑Complies Requirement will be met. 5.8.2.4 accordance with NFRC. ❑Does Not [FR12]z Location on plans/spec: ❑Not Observable 084113 ❑Not Applicable 5.8.2.2 Fenestration products are ❑Complies Requirement will be met. [FR13]1 certified as to perFormance labels ❑Does Not or certificates provided. ❑Not Observable Location on plans/spec: 084113 ❑Not Applicable 5.8.2.3, U-factor of opaque doors U- U- ❑Complies See the Envelope Assemblies 5.5.3.6 associated with the building � Swinging ❑ Swinging �Does Not tabre for values. [FR14]z thermal envelope meets � Nonswinging ❑ Nonswinging ❑Not Observable requirements. ❑Not Applicable Additional Comments/Assumptions: 1 High Impa�t (Tier 1) 2 Medium Impack (Tier 2) 3 Low Imp�ct (Tier 3) I �—•---- - - -- Project Giant Eagle Market District #6550 Report date: 09/16/1 Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 4 of 7 COMcheck R-20.cck Section # & Req.ID 5.4.3.1 [IN1]1 5.5.3.1 [IN2]1 Insulation Inspection PIanV luefied I Fie�Valuefied Complies? I Comments/Assumptions All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor-permeable wrapping material to minimize air leakage. Roof R-value. For some ceiling R- systems, verification may need to � Above deck occur during Framing Inspection. � Metal ❑ Attic 5.8.1.2, Roof insulation installed per ` 5.8.1.3 manufacturer's instructions. [IN3]1 Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. 5.5.3.1 Skylight curbs are insulated to R- [IN4]3 the level of roofs with insulation above deck or R-5. 5.5.3.1.1 High-albedo roofs meet solar SR: [IN5]3 reflectance of 0.70 and thermal SRI: emittance of 0.75 or SRI of 82. 5.5.3.2 Above-grade wall insulation R- R- [IN6]1 value. � Mass ❑ Metal ❑ Steel ❑ wood 5.8.1.2 [IN7]1 5.5.3.4 [IN8]1 Above-grade wall insulation installed per manufacturer's instructions. Floor insulation R-value 5.8.1.1 Building envelope insulation is [IN10]z labeled with R-value or insulation certificate providing R-value and other relevant data. 5.8.1.4 Eaves are baffled to deflect air to [IN11]z above the insulation. 5.8.1.5 Insulation is installed in [IN12]z substantial contact with the inside surface separating conditioned space from unconditional space. R- ❑ Mass ❑ Steel ❑ Wood ❑Complies Requirement will be met. �Does Not ❑Not Observable Location on plans/spec: ❑Not Applicable A701 R- ❑Complie5 See the Envelope Assemblies ❑ Above deck �Does Not tabie for values. ❑ Metal ❑Not Observable ❑ Attic ❑Not Applicable R- SR: SRI: R- ❑ Mass ❑ Metal ❑ Steel ❑ wood R- ❑ Mass ❑ Steel ❑ Wood ❑Complies Requirement will be met. ❑Does Not ❑Not Observable Location on plans/spec: A400 series, 075423 ❑Not Applicable ❑Cornpfies Requirement will be met. ❑Daes Nat ❑Not Observahle �ocation on plans/spec: ❑N�t Applieable A501, 086200 ❑Complies Requirement will be met. �Does Not ❑Not Observable Location on plans/spec: 075423 ❑Not Applicable ❑Complies See the Envelope Assemblies �Does Not table for values. ❑Not Observable ❑Not Applicable ❑Complies Requirement will be met. ❑Does Not ❑Not Observable Location on plans/spec: A400 series ❑Not Applicable ❑COmplies See the Envelope Assemblies �Does Not table for values. ❑Not Observable ❑Not Applicable ❑Complies Requirement will be met. �Does Not ❑Not Observable ❑Not Applicable ❑Complies Requirement will be met. �Does Not ❑Not Observable Location on plans/spec: ❑Not Applicable NA ❑Complies Requirement will be met. ❑Does Not ❑Not Observable Location on plans/spec: ❑Not Applicable A400 series 1 HEqh Impact (Tier 1) 2 Medium Impa�t (Tier 2) 3� Low Impact (Tier 3) � f_�� - - -! Project Giant Eagle Market District #6550 Report date: 09/16/1 Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 5 of 7 COMcheck R-20.cck # & Req.1D 5.$.I.fi [ IN 13I� Insufation Inspectfon Recessed equipment installed in building envelope assemblies does not compress the adjacent insulation. 5.$.I.7 Exterior insulation is protected (IN14]z from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation 5.8.1.7.1 Attics and mechanical rooms [II�iS]� have insulation protected where adjacent to attic or equipment access. 5.8.1.7.2 Foundation vents do not interfere [1Ni6]� with insulation. 5.8.1.8 � Insulation intended to meet the [IN17]3 I roof insulation requirements ��, cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordinal Additional Comments/Assumptions: Plans Verified Field Ver3fisd Value Value Campl€es7 LJComplies ❑Does Not ❑Not Observable ❑Not Applicable ❑Complies �Does Not ❑Not Observable ❑Not Applicable CommentslAss urrf p#ions Requirement will be met. Requirement will be met. Location on plans/spec: A400 series ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ! Location on plans/spec: A102, A106, A601 ❑Not Applicable ❑Complies ' Requirement will be met. ❑Does Not ❑Not Observable � �ocation on plans/spec: ❑Not Applicable A400 series ❑Complies Requirement will be met. ❑Does Not ❑Not Observable ' Location on plans/spec: ❑Not Applicable A400 series � 1�High Impact (Tier 1) 2 Medium Impact (Tier 2) �Low Impaet (Tier 3) _� Project Giant Eagle Market District #6550 Report date: 09/16/1 Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 6 of 7 COMcheck R-20.cck �a.i (2007] Finallnspectian Cvrrtp�ies? Comrr�entslAssumptions Standard 5.4.33 Weatherseals installed on all loading [�I1]' dock cargo doors in Climate Zones 4- 8. Additianal Comments/Assumptions: ;�Does Not ;❑Not Observable ❑Nok Applicable Requirement will be met. Location on plans/spec: A405, 083613 � High Impact (Tier 1) 2 Medium Irnpact ��ier 2j 3 tow Impact (Tier 3) � Proje�t Giant Eagle Market District #6550 Report 09/16/14 aata Q:\Aetos\Giant EagIe�6550-IN Carmel�Design Calculations\Giant Eagle #6550 Prelim Page 7 of 7 COMcheck R-20.cck