HomeMy WebLinkAboutEnvelope ComCheck 09_16_14.pdfCOMcheck Software Version 3.9.4
Envelope Compliance Certificate
90.1 (2007) Standard
Section 1: Project Information
Project Type: New Construction
Project Title : Giant Eagle Market District #6550
Construction Site:
Carmel, IN
Owner/Agent:
Giant Eagle Incorporated
254 Kappa Drive
Pittsburgh, PA
Section 2: General Information
Building Location (for weather data): Carmel, Indiana
Climate Zone: 5a
Building Space Conditioning Type(s): Nonresidential
Vertical Glazing / Wall Area Pct.: 11%
Buildina Tv�e
Retail
Floor Area
122137
Designer/Contractor:
William E. Hulsey, P.E.
McHenry & Associates, Inc.
25001 Emery Road
Suite #200
Warrensville Heights, OH 44128
216.292.4696
mai I@mche n ryassociates. com
�'��q ti•$G�5 T�'Qcs �,�.�:
�2� ¢ � ��
�� AR11400Q24 �_
�� STATE OF ��
�'� �N� I ANA �.`:
h_.e_ �c _♦
� w
• • � ' ' � � �
/
Envelope PASSES: Design 2% better than code
Climate-Specific Requirements:
Component Name/Description
Roof 1: Insulation Entirely Above Deck �
Skylight 1: Metal Frame with Thermal Break:Double Pane, Perf.
Type: Other testing/cert. Product ID: , SHGC 0.42 (c)
Exterior Wall 1: Other Steel Framed Wall (b)
�ndow 1: Metal Frame:Double Pane, Perf. Type: Other
testing/cert. Product ID: , SHGC 0.39 (c)
Door 1: Insulated Metal, Swinging
Gross
Area or
Perimeter
� 122137
1221
39870
4209
150
Cavity Cont. Proposed Budget
R-Value R-Value U-Factor U-Factor�a�
20.0 0.048 0.048
--- 0.740 0.690
--- 0.064 0.064
--- 0.250 0.550
--- 0.500 0.700
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)'Other' components require supporting documentation for proposed U-factors,
(c) Fenestrations product performance must be certfied in accordance with NFRC and requires supporting documentation.
Section 4: Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and
other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 90.1 (2007) Standard
requirements in C�Mcher.k Version 3.9.4 and to comply with the mandatory require snts in the �equirements Checklist.
�1�� �[ . ��'�1� A �• � - -- 91r �/ �
Project Title: Giant Eagle Market District #6550 Report date: 09/16114
Data filename: Q:Wetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim COMcheck R-20.cck Page 1 of 2
Name - Title Signature Date
Project Title: Giant Eagle Market District #6550 Report date: 09/16/14
Data filename: Q:Wetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim COMcheck R-20.cck Page 2 of 2
COMcheck Software Version 3.9.4
Inspection Checklist
Energy Code: 90.1 (2007) Standard
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Giant Eagle Market District #6550 Report date: 09/16/1
Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 1 of 7
COMcheck R-20.cck
(�flFf7j Plan Reniew Cvrnplles? I Cvmmen#slAssumptions
Standard
4.2.2 ; Plans and/or specifications provide all
[PRl]� I information with which compliance
; can be deYermined for the building
; envelope and document where
� exceptions to the standard are
; claimed.
Additional Comments/Assumptions:
;❑Complies
;❑Does Not
;❑Not Observable
;❑Not Applicable
Requirement will be met.
Location on plans/spec: A101-A, A106, A400 series
1 High Impa�t (Tier 1) 2 Medium Impact (Tier 2) 3 Low 1�paet (Tier 3j
Project Giant Eagle Market District #6550 Report date: 09/16/1
Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 2 of 7
COMcheck R-20.cck
'� #'� Faoting � Foundation
& iteq.lD Inspectivn
5.5.3.3 Below-grade wall insulation R-
[FOl]i value.
5.5.3.5 Slab edge insulation R-value.
[F03]1
5.5.3.5 Slab edge insulation
[F05]1 depthllength.
5.8.1.7.3 Insulation in contact with the
[F07]1 ground has <=0.3% water
absorption rate per ASTM C272.
Additional Comments/Assumptions:
Plans Veriffed I Field Verified �pmplies? Cvmmer+tslAss�mptions
Va[ue � Va�ue
R- __ R- ❑ComplieS ; See the Envelope Assemblies
R-
❑ Unheated
❑ Heated
ft
�Does Not ; table for values.
;❑Not Observable ;
;�Not Applicable ;
R- ❑Compiie5 See the EnvelopeAssemblies
❑ Unheated �Does Not table for values.
❑ Heated ;❑Not Observable
;❑Not Applicable
ft OCOmplfes See the Envelope Assemblies
❑DOeS Not table forvalues.
;❑Not Observable
;�Not Applicable
�Complies Requirement will be met.
❑L�aes Not
❑iVot Observable Location on plans/spec:
❑Nat Applicable 072100
� 1 I High Impact (Tier 1) ��Medium fmpact (Tier 2) 3 Low Impa�t (Tier 3) 1
Project Giant Eagle Market District #6550 Report date: 09/16/1
Data Q:�Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 3 of 7
COMcheck R-20.cck
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
5.4.3.2 Factory-built fenestration and Fenestration! Fenestration ❑Complies Requirement will be met.
[FR1]3 doors are labeled as meeting air _ cfm/ftz _ cfm/ftz ❑Does Not
leakage requirements. Doors Doors
❑Not Observable
cfm/ftz cfm/ftz ❑Not Applicable
5.4.3.4 Vestibules are installed where ❑Complies Exception: Requirement
[FR4]3 building entrances separate ❑Does Not does not apply.
conditioned space from the
exterior, and meet exterior ❑Not Observable
envelope requirements. Doors ❑Not Applicable
have self-closing devices, and are
>=7 ft apart.
5.5.4.3a Vertical fenestration U-Factor. � U- U- ❑Complies See the Envelope Assemblies
[FR8]1 ❑Does Not table forvalues.
❑Not Observable
❑Not Applicable
5.5.4.3b Skylight fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies
[FR9]1 ❑Does Not table forvalues.
❑Not Observable
❑Not Applicable
5.5.4.4.1 Vertical fenestration SHGC value. SHGC: SHGC: ❑Complies see the Envelope assemblies
[FR10]1 ❑Does Not table forvalues.
❑Not Observable
❑Not Applicable
5.5.4.4.2 Skylight SHGC value, SHGC: SHGC: ❑Complies See the Envelope Assemblies
[FR11]1 ❑Does Not table forvalues.
❑Not Observable
❑Not Applicable
5.8.2.1, Fenestration products rated in ❑Complies Requirement will be met.
5.8.2.4 accordance with NFRC. ❑Does Not
[FR12]z Location on plans/spec:
❑Not Observable 084113
❑Not Applicable
5.8.2.2 Fenestration products are ❑Complies Requirement will be met.
[FR13]1 certified as to perFormance labels ❑Does Not
or certificates provided. ❑Not Observable Location on plans/spec:
084113
❑Not Applicable
5.8.2.3, U-factor of opaque doors U- U- ❑Complies See the Envelope Assemblies
5.5.3.6 associated with the building � Swinging ❑ Swinging �Does Not tabre for values.
[FR14]z thermal envelope meets � Nonswinging ❑ Nonswinging ❑Not Observable
requirements.
❑Not Applicable
Additional Comments/Assumptions:
1 High Impa�t (Tier 1) 2 Medium Impack (Tier 2) 3 Low Imp�ct (Tier 3) I
�—•---- - - --
Project Giant Eagle Market District #6550 Report date: 09/16/1
Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 4 of 7
COMcheck R-20.cck
Section
#
& Req.ID
5.4.3.1
[IN1]1
5.5.3.1
[IN2]1
Insulation Inspection PIanV luefied I Fie�Valuefied Complies? I Comments/Assumptions
All sources of air leakage in the
building thermal envelope are
sealed, caulked, gasketed,
weather stripped or wrapped with
moisture vapor-permeable
wrapping material to minimize air
leakage.
Roof R-value. For some ceiling R-
systems, verification may need to � Above deck
occur during Framing Inspection. � Metal
❑ Attic
5.8.1.2, Roof insulation installed per `
5.8.1.3 manufacturer's instructions.
[IN3]1 Blown or poured loose-fill
insulation is installed only where
the roof slope is <=3 in 12.
5.5.3.1 Skylight curbs are insulated to R-
[IN4]3 the level of roofs with insulation
above deck or R-5.
5.5.3.1.1 High-albedo roofs meet solar SR:
[IN5]3 reflectance of 0.70 and thermal SRI:
emittance of 0.75 or SRI of 82.
5.5.3.2 Above-grade wall insulation R- R-
[IN6]1 value. � Mass
❑ Metal
❑ Steel
❑ wood
5.8.1.2
[IN7]1
5.5.3.4
[IN8]1
Above-grade wall insulation
installed per manufacturer's
instructions.
Floor insulation R-value
5.8.1.1 Building envelope insulation is
[IN10]z labeled with R-value or insulation
certificate providing R-value and
other relevant data.
5.8.1.4 Eaves are baffled to deflect air to
[IN11]z above the insulation.
5.8.1.5 Insulation is installed in
[IN12]z substantial contact with the
inside surface separating
conditioned space from
unconditional space.
R-
❑ Mass
❑ Steel
❑ Wood
❑Complies Requirement will be met.
�Does Not
❑Not Observable Location on plans/spec:
❑Not Applicable A701
R- ❑Complie5 See the Envelope Assemblies
❑ Above deck �Does Not tabie for values.
❑ Metal ❑Not Observable
❑ Attic ❑Not Applicable
R-
SR:
SRI:
R-
❑ Mass
❑ Metal
❑ Steel
❑ wood
R-
❑ Mass
❑ Steel
❑ Wood
❑Complies Requirement will be met.
❑Does Not
❑Not Observable Location on plans/spec:
A400 series, 075423
❑Not Applicable
❑Cornpfies Requirement will be met.
❑Daes Nat
❑Not Observahle �ocation on plans/spec:
❑N�t Applieable A501, 086200
❑Complies Requirement will be met.
�Does Not
❑Not Observable Location on plans/spec:
075423
❑Not Applicable
❑Complies See the Envelope Assemblies
�Does Not table for values.
❑Not Observable
❑Not Applicable
❑Complies Requirement will be met.
❑Does Not
❑Not Observable Location on plans/spec:
A400 series
❑Not Applicable
❑COmplies See the Envelope Assemblies
�Does Not table for values.
❑Not Observable
❑Not Applicable
❑Complies Requirement will be met.
�Does Not
❑Not Observable
❑Not Applicable
❑Complies Requirement will be met.
�Does Not
❑Not Observable Location on plans/spec:
❑Not Applicable NA
❑Complies Requirement will be met.
❑Does Not
❑Not Observable Location on plans/spec:
❑Not Applicable A400 series
1 HEqh Impact (Tier 1) 2 Medium Impa�t (Tier 2) 3� Low Impact (Tier 3) �
f_�� - - -!
Project Giant Eagle Market District #6550 Report date: 09/16/1
Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 5 of 7
COMcheck R-20.cck
#
& Req.1D
5.$.I.fi
[ IN 13I�
Insufation Inspectfon
Recessed equipment installed in
building envelope assemblies
does not compress the adjacent
insulation.
5.$.I.7 Exterior insulation is protected
(IN14]z from damage with a protective
material. Verification for exposed
foundation insulation may need
to occur during Foundation
5.8.1.7.1 Attics and mechanical rooms
[II�iS]� have insulation protected where
adjacent to attic or equipment
access.
5.8.1.7.2 Foundation vents do not interfere
[1Ni6]� with insulation.
5.8.1.8 � Insulation intended to meet the
[IN17]3 I roof insulation requirements
��, cannot be installed on top of a
suspended ceiling. Mark this
requirement compliant if
insulation is installed accordinal
Additional Comments/Assumptions:
Plans Verified Field Ver3fisd
Value Value
Campl€es7
LJComplies
❑Does Not
❑Not Observable
❑Not Applicable
❑Complies
�Does Not
❑Not Observable
❑Not Applicable
CommentslAss urrf p#ions
Requirement will be met.
Requirement will be met.
Location on plans/spec:
A400 series
❑Complies Requirement will be met.
❑Does Not
❑Not Observable ! Location on plans/spec:
A102, A106, A601
❑Not Applicable
❑Complies ' Requirement will be met.
❑Does Not
❑Not Observable � �ocation on plans/spec:
❑Not Applicable A400 series
❑Complies Requirement will be met.
❑Does Not
❑Not Observable ' Location on plans/spec:
❑Not Applicable A400 series
� 1�High Impact (Tier 1) 2 Medium Impact (Tier 2) �Low Impaet (Tier 3) _�
Project Giant Eagle Market District #6550 Report date: 09/16/1
Data Q:\Aetos\Giant Eagle\6550-IN Carmel\Design Calculations\Giant Eagle #6550 Prelim Page 6 of 7
COMcheck R-20.cck
�a.i
(2007] Finallnspectian Cvrrtp�ies? Comrr�entslAssumptions
Standard
5.4.33 Weatherseals installed on all loading
[�I1]' dock cargo doors in Climate Zones 4-
8.
Additianal Comments/Assumptions:
;�Does Not
;❑Not Observable
❑Nok Applicable
Requirement will be met.
Location on plans/spec: A405, 083613
� High Impact (Tier 1) 2 Medium Irnpact ��ier 2j 3 tow Impact (Tier 3) �
Proje�t Giant Eagle Market District #6550 Report 09/16/14
aata Q:\Aetos\Giant EagIe�6550-IN Carmel�Design Calculations\Giant Eagle #6550 Prelim Page 7 of 7
COMcheck R-20.cck