HomeMy WebLinkAboutP101a.pdfCOMPACTOR DRAIN WITH NEENAH FOUNDRY R-3705-4 CATCH BASIN TRAP.
PROVIDE HUB FOR DOWNSPOUT, COORDINATE EXACT LOCATION AND SIZEWITH ARCHITECTURAL DRAWINGS.
REFER TO SITE UTILITY DRAWINGS BY CIVIL ENGINEER FORCONTINUATION.
{CONNECT TO DOWNSPOUTS IN COLUMN PROVIDED WITH McGEECORPORATION CANOPY. VERIFY EXACT LOCATION, SIZES ANDREQUIREMENTS IN THE FIELD.
}PROVIDE PERFORATE PVC FOUNDATION DRAIN WITH GEOTEXTILE WRAPAS INDICATED AND EXTEND TO STORM INLETS ON SITE. COORDINATEWITH STRUCTURAL, ARCHITECTURAL AND CIVIL DRAWINGS.
{P.C. SHALL COORDINATE THE EXACT ROUTING OF THE RAIN ANDOVERFLOW RAIN CONDUCTORS DOWN THE COLUMNS WITH THEARCHITECT IN THE FIELD PRIOR TO STARTING WORK. CLEANOUTS SHALLNOT FACE OUT THE FRONT OF THE STORE WHEN POSSIBLE. CLEANOUTSSHOWN OUT OF PLACE FOR CLARITY - TYPICAL.
3" INCOMING DOMESTIC WATER SERVICE AND 8" FIRE PROTECTIONSERVICE UP THROUGH FLOOR WITH SHUTOFF VALVE AND FLANGECONNECTION 12" A.F.F.
8" DO-1, OVERFLOW DRAIN OUTLET 18" ABOVE FINISHED GRADE. SLEEVEAND SEAL WALL PENETRATION WATER TIGHT WITH SILICONE SEALER -TYPICAL.
PROVIDE BACKWATER VALVE FOR FOUNDATION DRAIN CONNECTION TOSTORM SYSTEM, JOSAM 67500 OR EQUIVALENT, WITH EXTENSION PIPE UPTO GRADE - TYPICAL.
REFER TO DRAWING P101A FOR CONTINUATION - TYPICAL.
SLEEVE AND SEAL FLOOR/WALL PENETRATION WATER TIGHT WITHSILICONE SEALER.
ROUTE 3" RAIN AND OVERFLOW RAIN CONDUCTORS IN JOIST SPACE ANDEXTEND THRU WALL. SPILL 3" RAIN AND OVERFLOW RAIN CONDUCTORSON LOWER ROOF. COORDINATE THE EXACT LOCATION IN THE FIELD PRIORTO STARTING WORK - TYPICAL.
}DOWNSPOUT FROM GUTTER SERVING COMPACTOR CANOPY. REFER TOARCHITECTURAL DRAWINGS FOR CANOPY DETAILS.{
}
{
}
{}
{
1234
5
6
7
8
*NOT ALL CODED NOTES APPLY.
A.