HomeMy WebLinkAboutA000-6 - COVER SHEET-CODE SUMMARY.pdfCODE SUMMARY
PROJECT INFORMATION:
NAME:ST. VINCENT CARMEL HOSPITAL
13500 N. MERIDIAN STREET
CARMEL, IN 46032
PROJECT DESCRIPTION:NEW WOMEN'S CENTER AND
CONNECTOR TO EXISTING HOSPITAL
OWNER ADDRESS:DUKE REALTY
100, 600 E. 96TH STREET
INDIANAPOLIS, IN 46240
CONTACT:KURT MEYER
317-808-6000
ARCHITECT:BSA LIFESTRUCTURES
9365 COUNSELORS ROW
INDIANAPOLIS, IN 46240
317-819-7878
APPLICABLE CODES:
2008 INDIANA BUILDING CODE (IBC)
2008 INDIANA FIRE CODE (IFC)
2000 LIFE SAFETY CODE NFPA 101
2009 INDIANA ELECTRICAL CODE (IEC)
2008 INDIANA MECHANICAL CODE (IMC)
2012 INDIANA PLUMBING CODE (IPC)
2010 INDIANA ENERGY CONSERVATION CODE (IECC)
MEDICAL OFFICE BUILDING
FLOOR/AREA AREA (GROSS)OCCUPANCY CLASSIFICATION
FIRST FLOOR WOMEN'S CENTER 27,107 SQ. FT.B
SECOND FLOOR WOMEN'S CENTER 21,079 SQ. FT.B
THIRD FLOOR WOMEN'S CENTER 21,028 SQ. FT.B
FOURTH FLOOR WOMEN'S CENTER 20,399 SQ. FT.B
FIRST FLOOR HOSPITAL CONNECTOR 1,894 SQ. FT.I-2
SECOND FLOOR HOSPITAL CONNECTOR 1,917 SQ. FT.R-1
THIRD FLOOR HOSPITAL CONNECTOR 1,973 SQ. FT.I-2
CONSTRUCTION TYPE:
ALLOWABLE AREA:
ALLOWABLE HEIGHT:
BUILDING DATA:
TYPE IIB (NON-COMBUSTIBLE, NON RATED) CONSTRUCTION
TABULAR AREA 23,000 SQ. FT.
FRONTAGE INCREASE +12,880 SQ. FT.
SPRINKLER INCREASE +46,000 SQ. FT.
ALLOWABLE PER FLOOR 81,880 SQ. FT.
5 STORIES; 75 FT.
LIFE SAFETY FEATURES:
SPRINKLER SYSTEM THROUGHOUT
STANDPIPE SYSTEM
FIRE RATED SEPARATION WALLS
FIREPROOFING AT APPLICABLE STEEL FRAMING AND FLOOR SLABS
SMOKE DETECTORS & FIRE ALARM SYSTEM
FIRE EXTINGUISHERS SPACED ACCORDINGLY
EMERGENCY LIGHTS - BATTERY BACK-UP
EXIT LIGHTS - BATTERY BACK-UP
BUILDING HEIGHT:4 STORIES; 67.5 FT.
HOSPITAL CONNECTOR
CONSTRUCTION TYPE:TYPE IA
BUILDING HEIGHT:3 STORIES
VARIANCE RECEIVED #12-12-36:
TABLE 705.4
A 2 HOUR FIRE BARRIER WILL BE USED IN LIEU OF THE REQUIRED 2 HOUR PARTY WALL TO SEPARATE THE NEW MEDICAL
OFFICE BUILDING (WOMEN'S CENTER) FROM THE EXISTING MEDICAL OFFICE BUILDINGS POB 1, 2, 3. A PARTY WALL IS NOT
PERMITTED TO HAVE OPENINGS. PATIENTS AND STAFF MUST MOVE BACK AND FORTH FROM THE HOSPITAL AND OTHER
MEDICAL OFFICE BUILDINGS THROUGH THE PARTY WALL INTO THE NEW WOMEN'S CENTER.
9365 Counselors Row
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
TM
WOMEN'S CENTER
13420 N. MERIDIAN ST., CARMEL, IN 46032
ST. VINCENT CARMEL HOSPITAL
WOMEN'S CENTER
BP #6 DESIGN
DOCUMENTS
OCT. 10, 2014
04610082
BID PACKAGE 6 - TENANT IMPROVEMENTS
DRAWING INDEX- BP6
11 - ELECTRICAL BP6
E001.6SYMBOLS AND ABBREVIATIONS
E140.6FOURTH FLOOR DEMOLITION PLAN
E240.6FOURTH FLOOR LIGHTING PLAN
E340.6FOURTH FLOOR POWER PLAN
E440.6FOURTH FLOOR SYSTEMS PLAN
E500.6ENLARGED ELECTRICAL ROOMS
E600.6ELECTRICAL SCHEDULES
E800.6ELECTRICAL DETAILS
DRAWING INDEX- BP6
09 - MECHANICAL BP6
H240.6FOURTH FLOOR HVAC PLAN
DRAWING INDEX- BP6
05 - PLUMBING BP6
P340.6FOURTH FLOOR PLUMBING PLAN - BP6
P430.6THIRD FLOOR SANITARY PLAN - BP6
P440.6FOURTH FLOOR SANITARY PLAN - BP6
P800.6SANITARY RISER DIAGRAM
DRAWING INDEX- BP6
03- INTERIORS - BP6
IF010.6FINISH SPECIFICATIONS AND NOTES
IF141.6FOURTH FLOOR FINISH PLAN
DRAWING INDEX- BP6
03- ARCHITECTURE - BP6
A010.6WALL TYPES, GENERAL NOTES AND DETAILS
A141.6FOURTH FLOOR DIMENSION PLAN
A142.6FOURTH FLOOR ARCHITECTURAL PLAN
A143.6FOURTH FLOOR REFLECTED CEILING PLAN
A500.6OPENING SCHEDULE AND DETAILS
A640.6FOURTH FLOOR INTERIOR ELEVATIONS
A641.6FOURTH FLOOR INTERIOR ELEVATIONS