HomeMy WebLinkAboutE001.6.pdf1. REFER TO SHEET `HPE' SERIES DRAWINGS FOR ADDITIONAL ELECTRICAL SCOPE. 2. ALL CONDUITS SHALL BE RUN ABOVE FINISHED FLOOR OF WHICH IT IS SERVING UNLESS OTHERWISE NOTED. CONDUITS ARE NOT PERMITTED, UNDER ANY CIRCUMSTANCES, TO BE RUN IN CONCRETE SLAB. 3. PLAN NOTES SHOWN OUTSIDE OF AREA MATCH LINES FOR EACH PROJECT SHEET SHALL NOT BE APPLICABLE TO SAID SHEET. 4. REFER TO ARCHITECTURAL SCHEDULES, DETAILS, ELEVATIONS FOR DEVICE MOUNTING HEIGHTS AND ADDITIONAL INFORMATION ON DEVICE LOCATIONS PRIOR TO ROUGH-IN. 5. ALL INTERRUPTIONS OF ELECTRICAL SYSTEMS SHALL BE COORDINATED AND SCHEDULED IN ADVANCE WITH THE CONSTRUCTION MANAGER AND OWNER. REFER TO SPECIFICATIONS FOR RESTRICTIONS AND ADVANCE NOTICE REQUIREMENTS. 6. VERIFY TYPE OF CEILING, GRID SYSTEM SPECIFICATIONS (IF APPLICABLE), AND MOUNTING RESTRICTIONS WITH ARCHITECTURAL DISCIPLINE PRIOR TO ORDER FOR LUMINAIRES. 7. MOUNTING OF JUNCTION BOXES BACK-TO-BACK IS NOT PERMITTED UNDER ANY CIRCUMSTANCES. 8. ELECTRICAL DEVICES INSTALLED ON VERTICAL FIRE RESISTIVE ASSEMBLIES CLASSIFIED AS FIRE/SMOKE PARTITIONS SHALL BE INSTALLED WITH OPENING ON ONE SIDE ONLY IN EACH FRAMING SPACE, AND THAT OPENING SHALL NOT EXCEED 16 SQUARE INCHES. ALL CLEARANCES BETWEEN SUCH DEVICES AND THE GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND OR OTHER UL APPROVED MATERIALS. 9. WHERE SPACE ALLOCATIONS WITH REGARD TO ELECTRICAL EQUIPMENT ARE NOT ADEQUATE FOR THE SPECIFIED ELECTRICAL EQUIPMENT, THE ENGINEER SHALL BE CONSULTED BEFORE ORDERING THE EQUIPMENT AND ANY INSTALLATION IS PERFORMED. 10. COORDINATE LOCATIONS OF ALL CEILING MOUNTED ELECTRICAL AND MECHANICAL EQUIPMENT INCLUDING-BUT NOT LIMITED TO-LUMINAIRES, PAGING SPEAKERS, SMOKE DETECTORS, ETC. WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. REFER TO SPECIFICATIONS FOR RESTRICTIONS OF PARTICULAR DEVICE PLACEMENT. 11. MAINTAIN AND SUBMIT AS-BUILT DRAWINGS SHOWING ALL MODIFICATIONS (BOTH IN THE FIELD AND AS DIRECTED BY OWNER OR ENGINEER) TO LIGHTING, POWER, AND SYSTEMS PLAN TO CONSTRUCTION MANAGER AT PROJECT OR PHASE COMPLETION. 12. PROVIDE NEW, TYPED PANELBOARD CIRCUIT DIRECTORIES IN EXISTING AND NEW PANELBOARDS MODIFIED BY THIS PROJECT. 13. REFER TO SITE PLANS LOCATED ON `C' SERIES SHEETS FOR ADDITIONAL ELECTRICAL SCOPE. 14. CONDUIT FLOOR SLEEVES SHALL BE INSTALLED 2" ABOVE FINISHED FLOOR AND SHALL BE FIRE PROOFED USING APPROVED FIRE RESISTIVE MATERIAL. 15. REFER TO ARCHITECTURAL PHASING PLAN FOR SPECIFIC PHASING CONSTRAINTS. ADJUST ELECTRICAL WORK ACCORDINGLY AND ENSURE THAT ALL SERVICES REMAIN ACTIVE IN ALL ACTIVE AND OCCUPIED AREAS THROUGHOUT THE PROJECT. 16. TO PROVIDE ORGANIZATION AND ACCESS, ALL CONDUIT, PIPING, DUCTWORK, ETC. ABOVE THE CEILING SHALL BE INSTALLED USING THE FOLLOWING CRITERIA: (A) ITEMS SHALL BE CLOSEST TO THE CEILING: SANITARY, STORM AND VENT PIPING, DOMESTIC COLD, HOT, HOT WATER RETURNS, CHILLED WATER SUPPLY AND RETURNS, STEAM AND FIRE PROTECTION. (B) MEDICAL GAS PIPING SHALL BE ABOVE ITEMS NOTED IN (A). (C) ELECTRICAL CONDUIT SHALL BE ABOVE ITEMS NOTED IN (B). (D) DUCTWORK SHALL BE ABOVE ITEMS NOTED IN (C) AND TO BE CLOSEST TO THE METAL DECK. DUCTWORK WHICH IS BELOW PIPING SHALL HAVE NO PIPE JOINTS ABOVE THE DUCTWORK. 17. ALL J-BOX IN CEILING SPACE SHALL HAVE ACCESS, TO COMPLY WITH NEC CLEARANCE REQUIRED. 18. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH ARCHITECTURAL ELEVATIONS PRIOR TO ROUGH-IN, AND ADJUST ROUGH-IN LOCATION ACCORDINGLY. 19. CONTRACTOR SHALL BE RESPONSIBLE TO FIRE PROOF PENETRATIONS AT SMOKE WALL, FIRE/SMOKE WALL, AND ROOF PENETRATIONS. 20. CONNECT ALL EXIT AND EGRESS LIFE SAFETY LIGHTING WITH #10 WIRING. 21. PRIOR TO INSTALLATION OF ALL TVS, MONITORS, OR FLAT SCREEN PANELS ROUGH-INS (TV, DATA, OR POWER RECEPTACLES), CONFIRM MOUNTING HEIGHT OF UNIT. 22. WALL AND CEILING MOUNTED EXIT SIGNS ARE NOT DISTINGUISHED DIFFERENTLY ON THE ELECTRICAL LIGHTING PLANS. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING MOUNTED DEVICES. COORDINATE EXACT LOCATION WITH BULKHEADS, SOFFITS, WALL WASHING LIGHT FIXTURES, OTHER WALL-MOUNTED DEVICES PRIOR TO INSTALLATION AND ORDERING OF UNITS AND ADJUST LOCATION AS REQUIRED WHILE STILL MAINTAINING DESIGN INTENT OF EGRESS SIGNAGE. COORDINATE ROUGH-IN LOCATIONS WITH ALL OTHER TRADES. 23. VOLTAGE DROP REQUIREMENTS: BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3 PERCENT TO COMPLY WITH THE REQUIREMENTS OF ASHRAE STANDARD 90.1-2007. THE FOLLOWING ARE MINIMUM ALLOWABLE CONDUCTOR SIZES BASED ON CIRCUIT LENGTH. THE CIRCUIT LENGTH SHALL BE MEASURED FROM THE BRANCH PANELBOARD TO THE FARTHEST DEVICE IN THAT CIRCUIT. THE PHASE AND NEUTRAL CONDUCTORS SHALL BE SIZED AS INDICATED THE ENTIRE LENGTH OF THAT CIRCUIT UNLESS A LARGER SIZE CONDUCTOR IS INDICATED ON THE DRAWINGS. BASED ON COPPER CONDUCTORS INSTALLED IN CONDUIT. CONDUCTOR SIZES FOR 20A/1-PHASE/120V CIRCUITS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: CIRCUIT LENGTH OF 0 TO 95 FEET: #12 AWG. CIRCUIT LENGTH OF 96 TO 150 FEET: #10 AWG. CIRCUIT LENGTH OF 151 TO 235 FEET: #8 AWG. CIRCUIT LENGTH OF 236 TO 380 FEET: #6 AWG. CONDUCTOR SIZES FOR 20A/1-PHASE/277V CIRCUITS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: CIRCUIT LENGTH OF 0 TO 200 FEET: #12 AWG. CIRCUIT LENGTH OF 201 TO 350 FEET: #10 AWG. CIRCUIT LENGTH OF 351 TO 550 FEET: #8 AWG. GENERAL NOTES: ST PC S D S K S P S4 S3 S S SD HD FD DD AR RI BD M FS TS H H C C S S V DH AM FACP FAAP FANP FATC FGCC FT RA B B M S S S V M M W TV AV MTV CCTV DR ES IC MI SCP ML CR MD DC PB K BS DS SM SS DE LC M OC J RT HEAVY CONTINUOUS LINES INDICATE SPRINKLER ZONESZ ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT LIGHT/SCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK LINE SYMBOLS HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED NOTE: A.GENERAL NOTE 1 PLAN NOTE FLOOR PLAN SYMBOLS ST - 20 AMP, 125VAC, SAFETY TYPE S - 20 AMP, 125VAC, SURGE GUARD PROTECTION TYPE WP - 20 AMP, 125VAC, WEATHERPROOF TYPE TOGGLE SWITCH - 20 AMP, 120/277VAC LETTER DESIGNATION INDICATES SWITCH LEG FLOOR BOX (POWER AND DATA) SPECIAL RECEPTACLE - EMERGENCY CIRCUIT (SEE DRAWINGS SPECIAL RECEPTACLE - NORMAL CIRCUIT (SEE DRAWINGS AND TOGGLE SWITCH - KEY OPERATED TOGGLE SWITCH - 3-WAY TOGGLE SWITCH - 4-WAY INDIVIDUAL LIGHT DIMMER TOGGLE SWITCH - PILOT LIGHT AND SPECIFICATIONS) PLUGSTRIP (POWER AND/OR DATA) SPECIFICATIONS) HM - 20 AMP, 125VAC, HORIZONTAL MOUNT TYPE IG - 20 AMP, 125VAC, ISOLATED GROUND TYPE GFCI - 20 AMP, 125VAC, GROUND FAULT CURRENT INTERRUPTER TYPE NONE - 20 AMP, 125VAC ELECTRICAL DEVICES DUPLEX RECEPTACLE - EMERGENCY CIRCUIT ("X" DENOTES QUADRAPLEX RECEPTACLE - NORMAL CIRCUIT ("X" DENOTES QUADRAPLEX RECEPTACLE - EMERGENCY CIRCUIT ("X" SIMPLEX RECEPTACLE - NORMAL CIRCUIT ("X" DENOTES AS SIMPLEX RECEPTACLE - EMERGENCY CIRCUIT ("X" DENOTES DUPLEX RECEPTACLE - NORMAL CIRCUIT ("X" DENOTES AS DESCRIPTION DENOTES AS FOLLOWS:) FOLLOWS:) AS FOLLOWS:) FOLLOWS:) AS FOLLOWS:) AS FOLLOWS:) SYMBOL FLOOR BOX (QUADRAPLEX) FLOOR BOX (DUPLEX) QUADRAPLEX - CEILING MOUNTED DUPLEX - CEILING MOUNTED DOOR SECURITY SYSTEM QUANTITY OF CONDUCTORS OR CABLES IN CONDUIT JUNCTION OR PULL BOX NEUTRAL GROUND RACEWAY SYSTEM DESCRIPTION PHASE CONDUCTORS SYMBOL SYMBOL DESCRIPTION GENERATOR/ALTERNATOR AUTOMATIC TRANSFER SWITCH G PUSHBUTTON OR PUSH PLATE PAD MOUNTED TRANSFORMER ("X" DENOTES KVA SIZE) BRANCH PANELBOARD AND CABINET - RECESSED MOUNT BRANCH PANELBOARD AND CABINET - SURFACE MOUNT DISTRIBUTION PANELBOARD AND CABINET - SURFACE MOUNT HORSEPOWER RATED MANUAL MOTOR STARTER TOGGLE SWITCH WITH THERMAL OVERLOAD PROTECTION COMBINATION MOTOR CONTROLLER DISCONNECT SWITCH - NON-FUSED MOTOR CONTROLLER DISCONNECT SWITCH - FUSED MOTOR ("X" DENOTES HORSEPOWER) GROUND CONNECTION ELECTRIC THERMOSTAT CAPACITOR ("X" DENOTES KVAR) T X PAGING/AUDIO SYSTEM MICROPHONE INPUT RECEPTACLE - WALL MOUNTED LOUDSPEAKER - WALL MOUNTED LOUDSPEAKER - CEILING MOUNTED SYMBOL VOLUME CONTROL DESCRIPTION WALL MOUNTED SPEAKER (ROUGH-IN) DESCRIPTION MOLDED CASE CIRCUIT BREAKER CURRENT TRANSFORMER ELECTRICAL EQUIPMENT SYMBOL FIRE ALARM SYSTEM SYMBOL DESCRIPTION TELEVISION SYSTEM SYMBOL TV SYSTEM OUTLET DESCRIPTION TELECOMMUNICATION SYSTEM VOICE ONLY OUTLET VOICE AND DATA OUTLET SYMBOL DESCRIPTION SMOKE DETECTOR ("X" DENOTES AS FOLLOWS) HEAT DETECTOR FLAME DETECTOR DUCT DETECTOR ("X" DENOTES AS FOLLOWS) MANUAL PULL STATION FLOW SWITCH TAMPER SWITCH HORN ONLY HORN STROBE CHIME ONLY CHIME STROBE SPEAKER ONLY SPEAKER STROBE VISUAL ONLY DOOR HOLD OPEN ADDRESSABLE MODULE BEAM DETECTOR FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM NOTIFICATION APPLIANCE PANEL FIRE ALARM TERMINAL CABINET S - SUPPLY R - RETURN R - RELAY BASE REMOTE TEST STATION REMOTE INDICATOR STATION DOOR BUZZER SECURITY DOOR ALARM MAGNETIC LOCK CCTV MONITOR OUTLET ELECTRIC DOOR OPENER ELECTRIC DOOR STRIKE INTERCOM UNIT FLUSH MTD. MASTER INTERCOM AND DIRECTORY UNIT MOTION DETECTOR CCTV COAXIAL CABLE OUTLET AND POWER OUTLET SECURITY CARD READER SECURITY CONTROL PANEL SECURITY DOOR CONTACTS SECURITY EXIT PUSH BUTTON SECURITY KEYPAD BIOSCAN ACCESS PAD CAMERA VOICE ONLY OUTLET (WALL OUTLET) DATA ONLY OUTLET PHOTO CELL X P.F. ADDRESSABLE RELAY LIGHTING DESCRIPTION 12x48 FLUORESCENT FIXTURE HALF SHADED INDICATES LIFE SAFETY POWER 24x24 FLUORESCENT FIXTURE 24" WALL LIGHTS 36" WALL LIGHTS 48" WALL LIGHTS 24x48 FLUORESCENT FIXTURE ("NL" DENOTES NIGHT LIGHT) DOWN LIGHT WALL MOUNTED SCONCE WALL MOUNTED EMERGENCY BATTERY LIGHT CEILING MOUNTED EMERGENCY BATTERY LIGHT EXIT LIGHT DIRECTIONAL ARROWS CEILING MOUNTED EXIT LIGHT (DUAL FACED) CEILING MOUNTED EXIT LIGHT WALL MOUNTED EXIT LIGHT EXTERIOR POLE LIGHTS (SINGLE HEADS) EXTERIOR POLE LIGHTS (DOUBLE HEADS) EXTERIOR POLE LIGHTS (THREE HEADS) EXTERIOR POLE LIGHTS (FOUR HEADS) EXTERIOR LIGHTS (BOLLARDS) 24" STEM MOUNTED WALL LIGHTS 36" STEM MOUNTED WALL LIGHTS 48" STEM MOUNTED WALL LIGHTS FULL SHADED INDICATES EMERGENCY POWER GROUND POINT GROUND ROD a X X FIRE ALARM GRAPHICS COMMAND CENTER FIREMEN'S TELEPHONE RESCUE ASSIST STATION BELL ONLY BELL STROBE MICROPHONE INPUT RECEPTACLE - FLOOR MOUNTED MICROPHONE INPUT RECEPTACLE - CEILING MOUNTED EXTERIOR POLE LIGHTS (POLE TOP MOUNT) GROUND FLOOD LIGHT EXTERIOR FLOOD LIGHT DUAL BALLAST (NORMAL AND EMERGENCY) CEILING MOUNTED (DATA, VOICE/DATA) FLOOR BOX (VOICE, DATA, VOICE/DATA) TELECOMMUNICATIONS EQUIPMENT RACK AUDIO/VISUAL CONTROLLER SECURITY DUTY STATION SECURITY STAFF STATION SECURITY MONITOR SECURITY DOOR EGRESS LIGHTING CONTROLLER MOTION DETECTOR (LIGHT SWITCH) OCCUPANCY SENSOR FLOOR BOX (BLANK) WIRELESS ACCESS POINTWA ABBREV. A or AMP AC A/C ACP ACU ADD ADJ AF AFC AFF AFG AHU AIC AL AM AMB APPROX. ARCH ATS AUTO AVG BC BKR BHP BL BLDG BR BTM C ºC CAB CB or C/B C/C CCTV CKT CL CLG COL COMM COMP CONC CONST CONT CONTR CR CT CU DB DC DEPT DF DIST DM DO DRS DWG EC EF ELEC ELEV ELV EMER ENCL EP EQUIP EWC EX EXH EXP EXT ºF FA FAAP FACP FC FCU FFC FFS FHC FIN FIXT FL FLUOR FLEX-CONN FPC FSS FTG FVR FV FVNR G or GND GALV GC GEN GFCI GFI GFP HGT HH HID HO HOA HORZ HP HPS HTR HV DESCRIPTION AMPERE ALTERNATING CURRENT AIR CONDITIONING ACCESS PANEL AIR CONDITIONING UNIT ADDITION ADJUSTABLE AMPERE FRAME ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT AMPERE INTERRUPTING CAPACITY ALUMINUM AMMETER AMBIENT APPROXIMATELY ARCHITECT AUTOMATIC TRANSFER SWITCH AUTOMATIC AVERGE BARE COPPER BREAKER BRAKE HORSEPOWER BUILDING LINE BUILDING BRANCH BOTTOM CONDUIT DEGREES CELSIUS CABINET CIRCUIT BREAKER CENTER TO CENTER CLOSED CIRCUIT TELEVISION CIRCUIT CENTER LINE CEILING COLUMN COMMUNICATION COMPRESSOR CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CRITICAL CURRENT TRANSFORMER COPPER DIRECT BURIAL DIRECT CURRENT DEPARTMENT DRINKING FOUNTAIN DISTRIBUTION DEMAND METER DRAWOUT DOCTORS DRAWING ELECTRICAL CONTRACTOR EXHAUST FAN ELECTRIC ELEVATOR ELEVATION EMERGENCY ENCLOSURE ELECTRIC PNEUMATIC EQUIPMENT ELECTRIC WATER COOLER EXPLOSIONPROOF EXHAUST EXPANSION EXTERIOR DEGREES FAHRENHEIT FIRE ALARM FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL FLAT CABLE FAN COIL UNIT FOOD FACILITY CONTRACTOR FOOD FACILITY SUPPLIER FIRE HOSE CABINET FINISH FIXTURE FLOOR FLUORESCENT FLEXIBLE CONNECTION FIRE PROTECTION CONTRACTOR FUSED SAFETY SWITCH FOOTING FILMVIEWER FULL VOLTAGE FULL VOLTAGE NON REVERSING GROUND GALVANIZED GENERAL CONTRACTOR GENERATOR GROUND FAULT CKT. INTERRUPTER GROUND FAULT INTERRUPTER GROUND FAULT PROTECTION HEIGHT HANDHOLE HIGH INTENSITY DISCHARGE HAND OPERATED HAND-OFF-AUTOMATIC HORIZONTAL HORSEPOWER HIGH PRESSURE SODIUM HEATER HIGH VOLTAGE ABBREV. HZ IC ID INCAN INCL ISG JB JT KEC KT KVA KVAR KW LAB LB LF LOC LS LT LTG LV MATV MAX MC MCB MCC MDP MECH MH MIN MISC MLO MTD MTG HT MU OD OFCI OFOI OPNG OPP OR P PB PBOX PE PF PH or Ø PV PNL PL PREFAB PRES PT PTS PW PWR RACU RAD RECEPT REF or REFR REINF RGIP RM RPM SA SC SG SHT SIG SN SPEC SQ SS SSSS STD STN STR SUSP SW SWBD SWGR TCC TELE TEMP TMH TV TYP UC U/C UH UV V VAC VB VC VEL VFD VM VOL VP VSD/VFC W/ W/O WTR WP WT XFMR Z DESCRIPTION HERTZ INTERCOMMUNICATION INSIDE DIAMETER INCANDESCENT INCLUDE ISOLATED GROUND SURGE GUARD JUNCTION BOX JOINT KITCHEN EQUIPMENT CONTRACTOR KITCHENETTE KILOVOLT AMPERE KILOVOLT AMPERE REACTIVE KILOWATT LABORATORY POUND LINEAR FEET LOCATION LIFE SAFETY LIGHT LIGHTING LOW VOLTAGE MASTER ANTENNA TELEVISION MAXIMUM MECHANICAL CONTRACTOR MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MECHANICAL MANHOLE MINIMUM MISCELLANEOUS MAIN LUGS ONLY MOUNTED MOUNTING HEIGHT MEDICINE UNIT OUTSIDE DIAMETER OWNER FURNISHED-CONTRACTOR INSTALLED OWNER FURNISHED-OWNER INSTALLED OPENING OPPOSITE OPERATING ROOM POLE PUSHBUTTON PULL BOX PNEUMATIC ELECTRIC CONVERTER POWER FACTOR PHASE POST INDICATOR VALVE PANELBOARD PILOT LIGHT PREFABRICATED PRESSURE PNEUMATIC TUBE PNEUMATIC TUBE STATION PART WINDING POWER ROOM AIR CONDITIONING UNIT RADIATION RECEPTACLE REFRIGERATOR REINFORCED REMOTE GROUND INDICATING PANEL ROOM REVOLUTIONS PER MINUTE SUPPLY AIR SHORT CIRCUIT SURGE GUARD PROTECTION SHEET SIGNAL SOLID NEUTRAL SPECIFICATIONS SQUARE SAFETY SWITCH SOLID STATE SOFT START STANDARD STATION STRUCTURAL SUSPENDED SWITCH SWITCHBOARD SWITCHGEAR TEMPERATURE CONTROL CONTRACTOR TELECOMMUNICATION TEMPERATURE TOP OF MANHOLE TELEVISION TYPICAL UNDER CARPET UNDER CABINET or UNDER COUNTER UNIT HEATER UNIT VENTILATOR VOLT VACUUM VACUUM BREAKER VACUUM CLEANING VELOCITY VARIABLE FREQUENCY DRIVE VOLTMETER VOLUME VAPORPROOF VARIABLE SPEED DRIVE/CONTROLLER WITH WITHOUT WATER WEATHERPROOF WEIGHT TRANSFORMER IMPEDANCE ELECTRICAL ABBREVIATIONS SYMBOL SYMBOL DESCRIPTION OC CEILING OCCUPANCY SENSOR M D S E P CB CP L Z W R A N NC IC X PC PC P IR RF BS CL WL 2X MO NURSE ASSIST NURSE ASSIST/CODE BLUE DUTY STATION DESCRIPTION MASTER STATION STAFF STATION STAFF LOCATOR STATION CODE BLUE STATION SYMBOL ROOM READY INDICATOR REMOTE ANNUNCIATOR NURSE STATION INPUT JACK BED CONTROL CABLE/INTERCONNECT JACK NURSE CALL SYSTEM PATIENT STATION - SINGLE OUTLET EMERGENCY/BATH STATION ZONE LIGHT WALL MOUNTED DOME LIGHT CODE PINK STATION NURSE AUXILARY JACK TELEMETRY ANTENNA LOCATION CEILING MOUNTED DOME LIGHT PULL CORD PULL CORD WITH AUDIOA PATIENT STATION - SINGLE OUTLET WITHECODE/STAFF ASSIST BUTTON TRACKING SENSOR (IR) TRACKING SENSOR (RF) WHITE BOARD MONITOR DOUBLE NURSE AUXILARY JACK ASCOM BASE STATION NL 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN NO SCALE 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH TMH JCP E001.6 SYMBOLS AND ABBREVIATIONS 0461 BP #6 DESIGN DOCUMENTS OCTOBER 10, 2014 MARKDATEDESCRIPTION