HomeMy WebLinkAboutE340.6.pdf. JJ J JJ J J J J J J J J J J J J JJ J E B B.6 7 8 95.2 5.8 10.1 D.6 D.3 C.9 C.6 C.4 4 C D 9.5 65 4LN2 4LN1 DP-4LN1 4TN1 4HN3 4HN2 4HN1 4LN3 +66" TV PRINT STST STST +36" +38" GFCI GFCI+38" ST REF +46" COFFEE GFCI +38" +38"GFCI +36" +36"+36" +36" +36"+36"+36" +36" +36" +36" 1 FB3 2 2 +62" MICRO +36" +36" +36" FB1FB1 MICRO+62" GFCI +66" TV +66" TV ST +66" TV 4LCP1FNAC GROUND BUS DDC WATER COOLER GFCI EWC +46" DW +38" GFCI +36" +36" +36" ST +38" GFCI CR CR 2 ST 45 +46" 1 1 1 1 1 4 3 3 3 3 3 27 5 5 54 4 2 2 2 27 27 14 14 18 14 1414 2 6 6 8 1010 10 1046 6 7 7 7 7 7 4 12 13 13 13 15 27 27 26 27 17 30 24 11 9999 9 9 99 11 11 11 22 24 22 20 25 25 24 24 24 24 8 8 8 11 11 11 12 8 10 1010 10 15 15 12 12 18 18 1818 19 19 27 26 1916 1616 16 16 19 19 27 2123 11 5 5 5 1 1 1 1 3 1 3 3 38 3 2 2 24 4 20 20 38 20 20 20 23 23 23 23 23 4 6 66 19 19 4 4 24 24 24 4 22 22 22 27 22 22 24 24 7 7 77 9 9 6 6 9 11 9 19 19 17 21 18 1818 18 18 14 14 1711 27 4 25 21 21 25 29 29 26 26 26 26 28 29 29 29 29 27 2727 27 28 2825 25 28 3030 25 1616 16 14 14 17 17 12 15 13 15 15 39 35 41 31 33 41 41 30 30 41 41 3737 39 39 32 40 3441 36 25 16 25 15 21 21 27 23 23 23 2525 6 US US 13 31 30 21 3 4 14 17 26 3 3 PASSAGE 4065 EXAM 10 4064EXAM 9 4059 PASSAGE 4058 EXAM 8 4057EXAM 5 4054 EXAM 6 4055 EXAM 7 4056 PASSAGE 4061 NURSE STATION 4060 PATIENT TOILET 4062 NURSE STATION 4063 EXAM 12 4067 EXAM 11 4066 PASSAGE 4068 CONFERENCE ROOM 4025 EXAM 13 4069 EXAM 14 4070 N.S.T. 4034 OFFICE 4024 PHYS. WORK 4023 PHYS. WORK 4022 COATS 4019 PASSAGE 4016 NURSE STATION 4028PATIENT TOILET 4029 NURSE STATION 4030COLPO. 4033 STAFF WORK 4006 CONSULT. 4035CONSULT. 4036 PASSAGE 4001 COPY / FAX 4002 CHECK IN / OUT 4003 PASSAGE 4005 PASSAGE 4032 EXAM 15 4027 STAFF TOILET 4018 PHYS. WORK 4021 STORAGE 4020 BREAK ROOM 4015 PASSAGE 4012 STORAGE 4014 SOILED HOLDING 4013 STAFF TOILET 4010 I.T. 4011 STAFF WORK 4008STAFF WORK 4007 MANAGER OFFICE 4004 PASSAGE 4012 WAITING 4000 ULTRASOUND 4040 LAB 4039 BLOOD DRAW 4038 PATIENT TOILET 4037 STORAGE 4043 EXAM 1 4044 EXAM 3 4047 EXAM 4 4051 PASSAGE 4052NURSE STATION 4050 PATIENT TOILET 4048 STAFF WORK 4046 PASSAGE 4049 ULTRASOUND 4041 EXAM 2 4045 PASSAGE 4042 STORAGE 4009 PHYS. WORK 4017 STAFF WORK 4007 PASSAGE 4061 ELECT 4004 IT 4003 IT 4002 GFCI+44"+44" GFCI GFCI +44" 11 11 +36" MON 13 10 MON GFCI GFCI +36" GFCI GFCI GFCIGFCI GFCIGFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI +44"GFCI +36" 2 2 +36" 2 5 +36" +36" 121010 8 8 12 +36" +36" +36" +36"+36" +36"+36" +36"+36" 7 7 9 9 26 +36" +44"+44" 5 2 38 38 +36" +36" +36" +36"+36" GFCI 21 GFCI19 +44" 19 26 26 28 28 30 30 16 16 +36" +36" +36" +36" +36" +36" +36" +36" +36"+36" 29 +44" 4 GFCI CR 3 +66" +66" 27 +44" +44" CR 3 10 13 TV 11 +66" GFCI GFCI +44" 29 +44" GFCI GFCI 39 TB-2-406 TB-2-407 CR CR CR 3 3 3 7 6 STORAGE 4049A 9 8 VEND M/C 10 11 12 13 U/C REF 14 28 U/C REF U/C REF +44" +44"+44" +44" PRINT CENTRIFUGE INC 15 +44" +44"15 GENERAL NOTES: A.REFER TO BP6 SHEET E001.6 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. B.REFER TO HPE, H, AND P SERIES DRAWINGS FOR ADDITIONAL INFORMATION AND ELECTRICAL SCOPE.9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH MEB JCP E340.6 FOURTH FLOOR POWER PLAN 0461 BP #6 DESIGN DOCUMENTS OCTOBER 10, 2014 1/8" = 1'-0"1 FOURTH FLOOR POWER PLAN PLAN NOTES 1PROVIDE MULTI SERVICE POKE THRU TYPE FLOOR BOX (FB3) SIMILAR TO WIREMOLD 8AT EVOLUTION WITH TWO DUPLEX RECEPTACLES WITH 3/4"C FOR POWER, ONE 1-1/4"C FOR MONITOR AND ONE 1-1/4"C FOR TELECOMMUNICATIONS (VOICE/DATA) REQUIREMENTS. ROUTE CONDUITS FROM FLOOR BOX ABOVE CEILING SPACE OF FLOOR BELOW TO NEAREST WALL AND UP ABOVE TO ACCESSIBLE CEILING IN THAT ROOM. 2PROVIDE MULTI SERVICE POKE THRU TYPE FLOOR BOX (FB1) SIMILAR TO WIREMOLD 6AT EVOLUTION WITH TWO DUPLEX RECEPTACLES WITH 3/4"C FOR POWER. ROUTE CONDUITS FROM FLOOR BOX ABOVE CEILING SPACE OF FLOOR BELOW TO NEAREST WALL AND UP ABOVE TO ACCESSIBLE CEILING IN THAT ROOM. 3CONNECT DOOR HARDWARE TO 20A, 1P, 120VAC CIRCUIT "4LN3-42" FOR DOOR ACCESS CONTROL SYSTEM. 4CONNECT RECEPTACLES IN THIS AREA TO 20A, 1P, 120 VAC CIRCUIT SHOWN FROM PANEL "4LN3". 5CONNECT RECEPTACLES IN THIS AREA TO 20A, 1P, 120 VAC CIRCUIT SHOWN FROM PANEL "4LN2". 6NEW LOCATION OF FAN POWER BOX, FPB-2-401. EXTEND/MODIFY EXISTING 30A, 3P, 480 VAC CIRCUIT AVAILABLE DUE TO DEMOLITION TO NEW LOCATION AND CONNECT COMPLETE. REFER TO SHEET H240.6 FOR FAN POWER BOX EXACT LOCATION. ALSO REFER TO DETAIL #6 ON E600.6 FOR ADDITIONAL SCOPE OF WORK. 7NEW TERMINAL BOX ADDED UNDER THIS PHASE. CONNECT COMPLETE TO 480 VAC , 3 PHASE, 4 WIRE 30A CIRCUIT "4HN2-(8,10,12)" WITH FEEDER SIZE F30. REFER TO SHEET H240.6 FOR EXACT LOCATION OF TB-2-406. ALSO REFER TO DETAIL #6 ON SHEET E600.6 FOR ADDITIONAL SCOPE OF WORK 8CONNECT DISHWASHER TO 20A, 1P, 120 VAC CIRCUIT SHOWN. PROVIDE DUPLEX RECEPTACLE IF DISHWASHER IS WITH CORD AND PLUG. 9CONNECT AUTO CLAVE TO 20A, 1P, 120 VAC CIRCUIT "4LN2-29" WITH FEEDER SIZE "F30". PROVIDE DUPLEX RECEPTACLE IF AUTO CLAVE IS WITH CORD AND PLUG. 10CONNECT NURSE CALL PANEL TO 20A, 1P, 120 VAC CIRCUIT "4LN1-16". COORDINATE LOCATION OF NURSE CALL PANEL WITH OWNER'S VENDOR. 11CONNECT ROOM STATUS PANEL TO 20A, 1P, 120 VAC CIRCUIT "4LN1-18". COORDIANTE LOCATION OF ROOM STATUS PANEL WITH OWNER'S VENDOR. 12CONNECT MUSAK SYSTEM AMPLIFIER TO 20A, 1P, 120 VAC CIRCUIT "4LN1-20". COORDINATE LOCATION MUSAK SYSTEM AMPLIFIER WITH OWNEER'S VENDOR. 13PROVIDE QUAD RECEPTACLE WITH 20A, 1P, 120 VAC DEDICATED CIRCUIT "4LN1-22" FOR TELEVISION AMPLIFIER. COORDINATE LOCATION OF QUAD RECEPTACLE WITH OWNER'S VENDOR. 14ALL RECEPTACLES IN THIS ROOM SHALL BE GFCI TYPE RECEPTALCES. MARKDATEDESCRIPTION