HomeMy WebLinkAboutBZA Information Booklet 032315 St. Elizabeth Ann Seton Catholic Church (building addition) Docket Number 15020001 SUA SPECIAL USE AMENDMENT CITY OF CARMEL, INDIANA March 23, 2015 Carmel Board of Zoning Appeals Applicant: St. Elizabeth Ann Seton Church Attorneys – Nelson & Frankenberger, P.C. Attn: Charles D. Frankenberger, Attorney 844-0106 Attn: Jon C. Dobosiewicz Professional Land Planner 844-0106 TABLE OF CONTENTS 1. Explanation of Request 2. Site Location Maps / Aerial Photographs 3. Site Plan over Aerial Photograph 4. Building Elevations 5. Photographs Illustrating Building Materials 6. Floor Plan 7. Landscaping Plan 8. Engineered Site Development Plan 9. Ballot Sheet 10. Finding of Fact TAB 1 Information/Background on the Development of Campus - St. Elizabeth Seton Catholic Church, 10655 Haverstick Road, Carmel, IN 46033 Current Campus consists of:  Church Building Space, approximately 45,000 Sq. Ft. constructed in 1985  Rectory – House for Clergy approximately 6,000 Sq. Ft. constructed 2004  Parish Life Center(PLC), approximately 23,700 Sq. Ft. constructed 2005-2006 o Note these are all separate buildings on the same property/campus. Total existing square footage 74,700. Why Add Space:  We have seen only modest growth over the last few years. In 2007 we had 1,829 registered families. At the end of 2014 we had over 2100 households. We do not expect this growth rate to increase substantially. The need to serve existing parishioners is the primary concern at this point in time.  Through a series of survey/meetings and a professional study conducted in the spring of 2012 it was determined that all ministries had a need for more space. The addition of the new social hall, 5 new ministry rooms plus 3 new conference rooms there will be ample space for all ministries.  The new ministry and meeting rooms will allow us to expand and engage more existing parishioners in the various spiritual journeys provided by all of our Seton ministries. With a sense of belonging and engagement, existing families are naturally more inclined to become involved in St. Elizabeth Seton Parish life.  One other factor was discovered, parishioners wanted the Church and the PLC connected. This addition will connect the Church building to the Parish Life Center and to have it all under one roof. Spaces to be Added: (approximately 21,000 Sq. Ft.)  A connection of the Church building to the Parish Life Center; it will be under roof, so that you will be able to walk from one space to another without going outside.  A new and larger social hall to the north of the existing social hall that will accommodate larger groups. It can be one large room or partitioned off to accommodate three different meeting areas and can seat approximately 400 people.  A space for a future and enlarged kitchen area that will serve more people quicker and serve the new social hall and other parish wide activities.  Additional ministry rooms that will accommodate the current numbers of those enrolled in various religious education programs.  Three large meeting rooms that will be open to all ministries and general meeting needs. This space can be configured as one large room or divided into three meeting rooms.  Office space for nine (9) existing staff members who currently share one (1) office space.  Additional restrooms in close proximity of new social hall, counselling rooms, workroom and additional storage areas. TAB 2 Site Location Map NORTH Gr a y R o a d 106th Street Ha v e r s t i c k R o a d SITE TAB 3 S PR O P O S E D B L D G . A D D I T I O N FF E = 7 6 0 . 1 6 S CW S CW R HW S HW R EX I S T I N G L A T E R A L T O R E M A I N 7 5 9 . 0 75 8 . 0 75 7 . 0 ST . E L I Z A B E T H A N N S E T O N SO C I A L H A L L A D D I T I O N 10 6 T H S T HAVERSTICK RD E TAB 4 P:\12071\Dwgs\Arch\A301.dwg, 2/3/2015 4:00:44 PM P:\12071\Dwgs\Arch\A302.dwg, 2/3/2015 4:02:18 PM TAB 5 TAB 6 P:\12071\Dwgs\Arch\A101.dwg, 2/3/2015 4:01:56 PM P:\12071\Dwgs\Arch\A211.dwg, 2/3/2015 4:30:47 PM TAB 7 TAB 8 N0 0 ° 0 4 ' 1 4 " E - 6 5 0 . 2 4 ' N70°48'2 6 " E - 2 1 8 . 6 9 ' ( C ) 2 1 8 . 6 2 ' ( D ) N34 ° 5 8 ' 2 9 " E - 3 1 9 . 2 9 ' ( C ) 3 1 9 . 7 5 ' ( D ) N34 ° 5 5 ' 3 2 " E - 3 1 4 . 4 9 ' ( C ) 3 1 4 . 3 8 ' ( D ) S0 0 ° 1 1 ' 5 8 " W - 1 2 8 8 . 5 5 ' ( C ) 1 2 8 8 . 1 7 ' ( D ) N89°18'03"W-756.49'(C)756.59'(D) N0 0 ° 0 4 ' 1 4 " E - 2 6 7 . 6 0 ' N89°18'03"W-365.00' S0 0 ° 0 4 ' 1 4 " W - 2 6 7 . 6 0 ' N89°18'03"W-215.00' N89°18'03"W-2672.98' S0 0 ° 0 4 ' 1 4 " W - 2 6 5 0 . 5 2 ' S PROPOSED B L D G . A D D I T I O N FFE = 760.1 6 S c.o. c.o. St. Elizabeth Ann Seton Catholic Church FOR CONSTRUCTION PLANS SWPPP PHASE I - INITIAL MEASURES LEGAL DESCRIPTION GRADING PLAN SITE PLAN COVER SHEET DESCRIPTION SHEET INDEX PROJECT DATA COUNTY, INDIANA PANEL #18057C0228G, 18057C0229G DATED NOVEMBER 19, 2014 THIS SITE LIES WITHIN FLOOD HAZARD ZONES X PER FIRM MAP FOR HAMILTON FLOOD ZONE STATEMENT PROJECT MAP 10655 Haverstick Road, CARMEL, IN C100 80' COVER SHEET VICINITY MAP S Project Site LOCATION MAP SITE Project Information: Project Title:St. Elizabeth Ann Seton-Social Hall Addition Address: 10655 Haverstick Road City/Town: Carmel County: Hamilton Civil Township:Clay Quarter:NESection:5Township:17-NRange:4-E Latitude:39° 56' 29.3" NLongitude:86° 05' 53.5" W Project Location:Northwest corner of East 106th Street and Haverstick Road. Project Description: Church Social Hall Zoning Information Site Zoning: S-U Adjacent Zoning: WEST:R-4SOUTH:S-1 EAST: S-2NORTH:S-2 Flood Information Flood Hazard Zone: FIRM Panel No.: 18057C0228G, 18057C0229G C301 C201 C100 No. 1.THIS PROJECT IS SUBJECT TO THE CITY OF CARMEL STORM WATER MANAGEMENT AND STORM WATER QUALITY ORDINANCES. 2.IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE FOOT OF THE PROPOSED RIGHT-OF-WAY. 3.NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 4.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY. 5.A SITE SPECIFIC STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IN ACCORDANCE WITH 327-IAC-15-5 WILL BE PREPARED AND SUBMITTED WITH THE FINAL CONSTRUCTION PLANS FOR THIS PROJECT. Part of the West Half of the Southeast Quarter of Section 5, Township 17 North, Range 4 East in Clay Township, Hamilton County, Indiana, described as follows: Beginning at the Southwest corner of the Southeast Quarter of Section 5, Township 17 North, Range 4 East; thence North 00 degrees 00 minutes 05 seconds East (assumed bearing) on the West line of said Southeast Quarter 650.24 feet to the centerline of an existing sanitary sewer; thence North 70 degrees 43 minutes 29 seconds East on said sewer centerline 218.62 feet to the center point of a manhole cover; thence North 34 degrees 52 minutes 52 seconds East on said sewer centerline 319.75 feet to the center point of a manhole cover; thence North 34 degrees 56 minutes 10 seconds East on said sewer centerline 314.38 feet to the center point of a manhole cover; thence North 81 degrees 49 minutes 06 seconds East on said sewer centerline 249.00 feet to the center point of a manhole cover; thence North 81 degrees 29 minutes 13 seconds East on said sewer centerline 253.52 feet to the center point of a manhole cover; thence North 69 degrees 41 minutes 38 seconds East on said sewer centerline 186.33 feet to the center point of a manhole cover; thence South 42 degrees 22 minutes 15 seconds East on said sewer centerline and prolongation thereof 144.06 feet to the East line of the West Half of said Southeast Quarter; thence South 00 degrees 04 minutes 44 seconds West on said East line 1288.17 feet to the south line of said Southeast Quarter; thence North 89 degrees 22 minutes 37 seconds West on said South line 756.59 feet to a point 580.00 feet South 89 degrees 22 minutes 37 seconds East of the Southwest corner of said Southeast Quarter; thence North 00 degrees 00 minutes 05 seconds East parallel with the West line of said Southeast Quarter 267.60 feet; thence North 89 degrees 22 minutes 37 seconds West parallel with said South line 365.00 feet; thence South 00 degrees 00 minutes 05 seconds West parallel with said West line 267.60 feet to said South line; thence North 89 degrees 22 minutes 37 seconds West on said south line 215.00 feet to the place of beginning, containing 32.349 acres, more or less. Subject to the statutory easements for the rights-of-way for the W.C. Moffitt and Asa Williamson legal drains crossing said real estate. Subject also to a 30 foot wide utility easement across the easterly 30 feet of said real estate per instrument recorded in Miscellaneous Record 99, page 158 and Miscellaneous Record 11, page 314. Subject also to a storm sewer easement granted to the City of Carmel per instrument record in Deed Record 274, pages 600-602. Subject to a sanitary sewer, centered on the northerly line of the above described real estate. Subject further to all other legal easements and rights-of-way. Br Brookston Silty Clay Loam MmB2 Miami Silt Loam2 to 6 percent slopes, eroded PROJECT SOIL SURVEY SOILS MAP SWPPP PHASE II - FINAL MEASURES SWPPP DETAILSC403 C402 C401 SWPPP INFORMATION SHEETC404 UTILITY PLANC501 GENERAL SITE NOTES MmD2 Westland Silty Clay LoamWe Miami Silt Loam12 to 18 percent slopes, eroded0 to 2 percent slopes Job No. Date:JANUARY 16, 2015 Scale: Sheet: FO R CO N S T R U C T I O N P L A N S RE V I S I O N S DA T E D E S C R I P T I O N MA R K CA R M E L , I N D I A N A PR E P A R E D B Y : Title: PR E P A R E D F O R : 14016L 83 6 5 K e y s t o n e C r o s s i n g , S u i t e 2 0 1 In d i a n a p o l i s , I N . 4 6 2 4 0 ( 3 1 7 ) 2 0 2 - 0 8 6 4 FOR REVIEW BENCHMARK INFORMATION "X" Cut on top flange bolt on hydrant at Northwest corner of project site and the South side of the Main Drive West of a Garage BM Elevation = 758.44 (NAVD 88) UTILITIES GAS Vectren Energy 16000 Allisonville Rd. Noblesville, IN 46060 (317) 776-5532 WATER Carmel City Utilities Department 30 W. Main St., Suite 220 Carmel, IN 46032 (317) 571-2443 TELEPHONE Carmel AT&T Engineer 5858 N College Ave Indianapolis, IN 46220 (317) 252-4275 CABLE TELEVISION Brighthouse Networks 3030 Roosevelt Ave. Indianapolis, IN 46218 (317) 632-9077 x 291 (713-3899) ELECTRIC Duke Energy 16475 Southpark Dr. Westfield, IN 46074 (317) 896-6711 SANITARY SEWER Clay Township Regional Waste District 10701 N. College Ave, Suite A Indianapolis, IN 46280 (317) 844-9200 STORM SEWER Carmel Engineering Department Storm Water Administrator 1 Civic Sq., 1st Floor Carmel, IN 46032 STREETS Carmel Street Department 3400 W. 131st St Carmel, IN, 46074 (317) 733-2001 STORMWATER MANAGEMENT PLANC200 SITE DETAILSC601-C607 DEMOLITION PLANC101 S PROPOSED B L D G . A D D I T I O N FFE = 760.1 6 S c.o. c.o. C200 KEY Job No. Date:JANUARY 16, 2015 Scale: Sheet: FO R CO N S T R U C T I O N P L A N S RE V I S I O N S DA T E D E S C R I P T I O N MA R K CA R M E L , I N D I A N A PR E P A R E D B Y : Title: PR E P A R E D F O R : 14016L 83 6 5 K e y s t o n e C r o s s i n g , S u i t e 2 0 1 In d i a n a p o l i s , I N . 4 6 2 4 0 ( 3 1 7 ) 2 0 2 - 0 8 6 4 FOR REVIEW PROJECT DRAINAGE SUMMARY 9.4-ac9.4-ac 7160 2.87-cfs 1.10 cfs10.79 cfs Area of Interest CN Pre-Developed 100-year 10-year Condition Current Developed 4.38-cfs-----WQf 2.76 cfs2-year 744.42'-----MLAG 43,560-cft-----WQv 13.8%0%% Impervious STORM WATER MANAGEMENT PLANBENCHMARK INFORMATION "X" Cut on top flange bolt on hydrant at Northwest corner of project site and the South side of the Main Drive West of a Garage BM Elevation = 758.44 (NAVD 88) FR PROPOSED STORM SEWER LEGEND FLOOD ROUTE 9.9-ac 91 3.92-cfs 1.97 cfs 4.38-cfs 744.88' 43,560-cft 21% Proposed Developed LEGAL DESCRIPTION Part of the West Half of the Southeast Quarter of Section 5, Township 17 North, Range 4 East in Clay Township, Hamilton County, Indiana, described as follows: Beginning at the Southwest corner of the Southeast Quarter of Section 5, Township 17 North, Range 4 East; thence North 00 degrees 00 minutes 05 seconds East (assumed bearing) on the West line of said Southeast Quarter 650.24 feet to the centerline of an existing sanitary sewer; thence North 70 degrees 43 minutes 29 seconds East on said sewer centerline 218.62 feet to the center point of a manhole cover; thence North 34 degrees 52 minutes 52 seconds East on said sewer centerline 319.75 feet to the center point of a manhole cover; thence North 34 degrees 56 minutes 10 seconds East on said sewer centerline 314.38 feet to the center point of a manhole cover; thence North 81 degrees 49 minutes 06 seconds East on said sewer centerline 249.00 feet to the center point of a manhole cover; thence North 81 degrees 29 minutes 13 seconds East on said sewer centerline 253.52 feet to the center point of a manhole cover; thence North 69 degrees 41 minutes 38 seconds East on said sewer centerline 186.33 feet to the center point of a manhole cover; thence South 42 degrees 22 minutes 15 seconds East on said sewer centerline and prolongation thereof 144.06 feet to the East line of the West Half of said Southeast Quarter; thence South 00 degrees 04 minutes 44 seconds West on said East line 1288.17 feet to the south line of said Southeast Quarter; thence North 89 degrees 22 minutes 37 seconds West on said South line 756.59 feet to a point 580.00 feet South 89 degrees 22 minutes 37 seconds East of the Southwest corner of said Southeast Quarter; thence North 00 degrees 00 minutes 05 seconds East parallel with the West line of said Southeast Quarter 267.60 feet; thence North 89 degrees 22 minutes 37 seconds West parallel with said South line 365.00 feet; thence South 00 degrees 00 minutes 05 seconds West parallel with said West line 267.60 feet to said South line; thence North 89 degrees 22 minutes 37 seconds West on said south line 215.00 feet to the place of beginning, containing 32.349 acres, more or less. Subject to the statutory easements for the rights-of-way for the W.C. Moffitt and Asa Williamson legal drains crossing said real estate. Subject also to a 30 foot wide utility easement across the easterly 30 feet of said real estate per instrument recorded in Miscellaneous Record 99, page 158 and Miscellaneous Record 11, page 314. Subject also to a storm sewer easement granted to the City of Carmel per instrument record in Deed Record 274, pages 600-602. Subject to a sanitary sewer, centered on the northerly line of the above described real estate. Subject further to all other legal easements and rights-of-way. 744.42'-----MFPG 744.88' =MINIMUM LOWEST ADJACENT GRADEMLAG =MINIMUM FLOOD PROTECTION GRADEMFPG ADD NEW CONCRETE END SECTION WITH TRASH/DEBRIS GUARD FR FR FR FR FR FR FR FR F R F R FR FR F R FR F R FR F R FR FR SCALE: 1" = 60' 1 1 1 1 1 PROPOSED B L D G . A D D I T I O N FFE = 760.1 6 S C201 SITE PLAN 1.ALL DIMENSIONS SHOWN ARE MEASURED TO THE BACK OF CURB, UNLESS OTHERWISE SHOWN 2.ALL RADII SHALL BE 5 FEET UNLESS OTHERWISE SHOWN. 3.DIMENSIONS TO THE BUILDING ARE MEASURED TO THE EXTERIOR OF THE FOUNDATION WALL UNLESS OTHERWISE SHOWN. 4.BEARINGS, DIMENSIONS AND EASEMENTS ARE SHOWN FOR REFERENCE. REFER TO RECORDED PLATS AND SURVEYS FOR ADDITIONAL PROPERTY INFORMATION. 5.REFER TO ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS AND DETAILS. 6.PARKING SPACE STRIPES SHALL BE 4 INCHES WIDE. YELLOW OR WHITE STRIPES SHALL BE PROVIDED AT OWNER'S PREFERENCE UNLESS OTHERWISE SHOWN. 7.SEE SHEETS C601-C601-C602 FOR DETAILS REFERENCED ON THIS SHEET. 8.TRANSVERSE EXPANSION JOINTS ARE TO BE PROVIDED IN CONCRETE SIDEWALKS AND COMBINED WALKS/CURBS WHERE SHOWN AND AT INTERVALS NOT TO EXCEED 12 X THE WIDTH OF THE WALK. 9.EXPANSION JOINTS SHALL BE INSTALLED IN CONCRETE PAVEMENTS AND WALKS AT ALL LOCATIONS WHERE PAVEMENTS AND WALKS ABUT A VERTICAL SURFACE SUCH AS A CURB, WALL, COLUMN, ETC. 10.CONTRACTION JOINTS SHALL BE PROVIDED AT EQUAL INTERVALS BETWEEN EXPANSION JOINTS IN CONCRETE WALKS. INSTALL CONTRACTION JOINTS AS SHOWN BUT IN NO CASE AT INTERVALS GREATER THAN 1.5 X THE WIDTH OF THE WALK. 11.UNLESS OTHERWISE SHOWN, PERMANENT SIGNS SHALL BE MOUNTED ON A SINGLE U-CHANNEL DRIVE POST DRIVEN 42 INCHES BELOW GRADE. THE BOTTOM EDGE OF THE SIGN SHALL BE 6 FEET ABOVE THE NEAREST PAVEMENT EDGE ELEVATION. SITE DEVELOPMENT PLAN NOTES 1.THE CONTRACTOR SHALL ENSURE THAT ALL NECESSARY PERMITS AND APPROVALS HAVE BEEN OBTAINED FROM AGENCIES HAVING JURISDICTION OVER THE WORK PRIOR TO COMMENCING CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL OBTAIN AND PAY THE COST OF ALL PERMITS THAT HAVE NOT BEEN SECURED BY THE OWNER. 2.THE CONTRACTOR SHALL COMPLY WITH THE CONSTRUCTION SAFETY STANDARDS AS ISSUED BY THE U.S. DEPARTMENT OF LABOR OCCUPATIONAL HEALTH AND SAFETY ADMINISTRATION AS SET FORTH IN FINAL RULE 29, PART 1926, WHERE SUCH REGULATIONS APPLY TO THE WORK. 3.ALL ELEVATIONS SHOWN WITHIN THESE PLANS ARE BASED UPON U.S.G.S. DATUM. 4.LOCATIONS OF UTILITIES SHOWN WITHIN THESE PLANS ARE BASED UPON INFORMATION OBTAINED FROM UTILITY COMPANIES OR THEIR REPRESENTATIVES AND FIELD EVIDENCE OF IMPROVEMENTS VISIBLE ON THE GROUND SURFACE. EXACT LOCATIONS OF UNDERGROUND UTILITIES HAVE NOT BEEN VERIFIED. THE CONTRACTOR SHALL NOTIFY UTILITY COMPANIES AND REQUEST FIELD LOCATIONS OF SUCH WITHIN THE WORK AREA PRIOR TO COMMENCING EXCAVATION ACTIVITIES. THE CONTRACTOR SHALL REPORT ANY VARIATIONS FROM THE LOCATIONS SHOWN THAT MAY PRESENT A CONFLICT WITH EXECUTION OF THE WORK TO THE ENGINEER IN ADVANCE OF CONSTRUCTION. 5.THE CONTRACTOR SHALL COORDINATE WITH THE RESPECTIVE UTILITY COMPANIES AND SHALL PAY THE COST OF PROTECTION, RELOCATION, REMOVAL, CONNECTION, AND/OR RECONNECTION OF UTILITIES AS NECESSARY FOR EXECUTION OF THE WORK. 6.MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CODES, SPECIFICATIONS, LOCAL ORDINANCES, INDUSTRY STANDARDS AND UTILITY COMPANY REGULATIONS. 7.TRAFFIC CONTROL DEVICES SHALL BE FURNISHED, ERECTED, MAINTAINED AND REMOVED BY THE CONTRACTOR IN ACCORDANCE WITH THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. TYPE "C" LIGHTS SHALL BE REQUIRED ON ALL BARRICADES, DRUMS AND SIMILAR DEVICES IN USE AT NIGHT. GENERAL SITE NOTES CU-1 CU-1 CU-8 CU-6 PA-4 PA-3 AC-3, AC-4 CU-16 PA-10 PA-1S PA-1H PA-1R PA-2 PA-7A PA-7A PA-7A PA-7A AC-1+AC-2 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 1 2 3 4 5 LANDSCAPE AREA - SEE LANDSCAPE PLAN ACCESSIBLE PARKING SPACE WITH SIGN PAVEMENT STRIPING -PAINTED CROSSWALK PAVEMENT STRIPING -PAINTED ISLAND PAVEMENT STRIPING -CENTER -DOUBLE YELLOW PAVEMENT STRIPING -24" STOP BAR CONCRETE PAVEMENT SECTION PAVEMENT SECTION WITHIN THE RIGHT-OF-WAY HEAVY DUTY ASPHALT PAVEMENT SECTION STANDARD DUTY ASPHALT PAVEMENT SECTION CONCRETE COLLAR FOR CASTING WITHIN ASPHALT CONCRETE PARKING BUMPER ADA CURB RAMP CONCRETE SIDEWALK COMBINED WALK AND CURB CURB END TRANSITION STRAIGHT CURB REVERSE SLOPE CHAIRBACK CURB AND GUTTER CHAIRBACK CURB AND GUTTER SITE PLAN KEY NOTE LEGEND SITE PLAN DESCRIPTION LINE TYPE/ SYMBOL DETAIL REFERENCE PAVEMENT STRIPING - PARKING BAY STRIPE PA-7A KEY Job No. Date:JANUARY 16, 2015 Scale: Sheet: FO R CO N S T R U C T I O N P L A N S RE V I S I O N S DA T E D E S C R I P T I O N MA R K CA R M E L , I N D I A N A PR E P A R E D B Y : Title: PR E P A R E D F O R : 14016L 83 6 5 K e y s t o n e C r o s s i n g , S u i t e 2 0 1 In d i a n a p o l i s , I N . 4 6 2 4 0 ( 3 1 7 ) 2 0 2 - 0 8 6 4 FOR REVIEW SCALE: 1" = 30' SS SS SS SS SS STR. NO. 602A TC = 759.0 PROPOSED B L D G . A D D I T I O N FFE = 760.1 6 STR. NO. 601 TC = 759.72 STR. NO. 602 TC = 759.80 STR. NO. 604 TC = 748.20 S S S S SS S c.o. c.o. STR. NO. 604 TC = 748.20 760.21 760.14 760.14 760.14 760.14 760.14 759.71 759.53 759.18 759.71 759.71 760.21 761.21 BW 760.00 761.00 BW TW TW 759.8±ME 758.8±ME 759.75 758.2±ME758.0±ME 758.4±ME758.0±ME 758.5±ME758.3±ME 759.2±ME 759.5±ME759.35 759.00 758.50 759.57 759.84 GRADING NOTES 1.TOPSOIL SHALL BE STRIPPED FROM ALL AREAS TO RECEIVE PAVING AND FROM WITHIN THE LIMITS OF PROPOSED BUILDINGS AND STRUCTURES. TOPSOIL SHALL BE STRIPPED TO THE DEPTH SHOWN IN THE GEOTECHNICAL REPORT, OR TO A DEPTH OF 6 INCHES, WHICHEVER IS GREATER. 2.TOPSOILSHALL BE PLACED TO A DEPTH OF 4 TO 6 INCHES IN ALL AREAS TO BE SEEDED OR SODDED PER THE SPECIFICATIONS. 3.EXCESS TOPSOIL MAY BE PLACED IN MOUNDING AREAS AND NONSTRUCTURAL FILL AREAS AS AVAILABLE. 4.ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE SEEDED OR SODDED UNLESS OTHERWISE SHOWN. 5.FINAL GRADES AT THE PROJECT BOUNDARY SHALL MATCH EXISTING ELEVATIONS UNLESS OTHERWISE SHOWN. 6.THE CONTRACTOR SHALL PERFORM AN EARTHWORK QUANTITY ANALYSIS PRIOR TO COMMENCING CONSTRUCTION TO CONFIRM SUCH QUANTITIES WITH THE ENGINEER. ADJUSTMENTS TO PROPOSED FINISH GRADES BASED UPON THE EARTHWORK QUANTITY ANALYSIS SHALL BE APPROVED BY THE ENGINEER. INDEX CONTOUR INTERMEDIATE CONTOUR POND TOP OF BANK POND NORMAL POOL HIGH POINT POND BOTTOM DESCRIPTION TOP & BOTTOM OF WALL PIPE INVERT ELEVATION ELEVATION MATCH EXISTING TOP OF CURB AND PAVEMENT SPOT GRADE GROUND SPOT GRADE H:V RATIO GRADE GUTTER GRADE :13 IE:805.55 800 801 GRADING PLAN LEGEND DESCRIPTION F.F.E. L.Pt. H.Pt. LOW POINT SWALE %1.00 C301 GRADING PLAN KEY Job No. Date:JANUARY 16, 2015 Scale: Sheet: FO R CO N S T R U C T I O N P L A N S RE V I S I O N S DA T E D E S C R I P T I O N MA R K CA R M E L , I N D I A N A PR E P A R E D B Y : Title: PR E P A R E D F O R : 14016L 83 6 5 K e y s t o n e C r o s s i n g , S u i t e 2 0 1 In d i a n a p o l i s , I N . 4 6 2 4 0 ( 3 1 7 ) 2 0 2 - 0 8 6 4 FOR REVIEW SCALE: 1"=30' BENCHMARK INFORMATION "X" Cut on top flange bolt on hydrant at Northwest corner of project site and the South side of the Main Drive West of a Garage BM Elevation = 758.44 (NAVD 88) 1.REFER TO MECHANICAL, ELECTRICAL AND PLUMBING PLANS FOR CONTINUATION OF UTILITIES WITHIN 5 FEET OF STRUCTURES. 2.PRESSURE UTILITY MAINS AND SERVICE LINES MAY NEED TO BE INSTALLED AT A DEPTH GREATER THAN THAT SPECIFIED OR SHOWN ON THE DRAWINGS TO CLEAR EXISTING AND PROPOSED CROSSING UTILITIES. IN SUCH CASES, THE CONTRACTOR SHALL INSTALL VERTICAL BENDS AS REQUIRED TO ACHIEVE APPROPRIATE CLEARANCE BETWEEN THE CROSSING UTILITIES. 3.A MINIMUM HORIZONTAL SEPARATION OF 10 FEET BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT ALL TIMES. A MINIMUM VERTICAL SEPARATION OF 18 INCHES BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT CROSSINGS. IN THE EVENT THAT MINIMUM SEPARATION REQUIREMENTS CANNOT BE MET, THE CONTRACTOR SHALL UTILIZE PRESSURE-TYPE WATER PIPE FOR THE SEWER PER DETAIL SA-9. 4.WATER MAINS SHALL BE INSTALLED WITH A MINIMUM OF 54 INCHES OF COVER AS MEASURED FROM THE TOP OF THE PIPE TO THE FINAL FINISH GRADE ABOVE THE PIPE. 5.THRUST BLOCKS OR JOINT RESTRAINTS SHALL BE INSTALLED ON ALL WATER LINES AT ALL BENDS, TEES AND HYDRANTS PER THE DETAILS. 6.PIPE LENGTHS SHOWN ARE MEASURED FROM CENTER TO CENTER OF STRUCTURES ROUNDED TO THE NEAREST FOOT. 7.PIPE LENGTHS SHOWN FOR STORM SEWERS ARE MEASURED TO THE DOWNSTREAM END OF END SECTIONS. 8.WHERE GRADE MODIFICATIONS (CUT OR FILL) ARE SHOWN ADJACENT TO EXISTING VALVE BOX COVERS AND MANHOLE CASTINGS, THE VALVE BOX COVERS AND MANHOLE CASTINGS SHALL BE ADJUSTED FLUSH WITH THE PROPOSED GRADE. 9.ADJUSTMENTS OF EXISTING MANHOLE CASTINGS TO GRADE TO A MAXIMUM OF 12 INCHES SHALL BE MADE USING PRECAST CONCRETE ADJUSTING RINGS, PROVIDED THE TOTAL HEIGHT OF EXISTING AND NEW ADJUSTING RINGS DOES NOT EXCEED 12 INCHES. 10.ADJUSTMENTS OF CASTINGS WHERE THE TOTAL HEIGHT OF ADJUSTING RINGS WOULD EXCEED 12 INCHES SHALL BE MADE BY REPLACING THE CONE AND/OR BARREL SECTION OF THE STRUCTURE. 11.PAVEMENTS, WALKS, CURBS AND OTHER SURFACE IMPROVEMENTS REQUIRING REMOVAL FOR INSTALLATION OF UNDERGROUND UTILITIES SHALL BE RESTORED TO THEIR PRESENT CONDITION UNLESS OTHERWISE SHOWN. 12.MANHOLE CASTINGS LOCATED WITHIN ASPHALT PAVEMENT AREAS SHALL INCLUDE A CONCRETE PAVED COLLAR EXTENDING A MINIMUM OF 12 INCHES IN ALL DIRECTIONS FROM THE EDGE OF THE CASTING PER THE DETAILS. 13.THE CONTRACTOR SHALL MAINTAIN ALL FLOWS AND UTILITY CONNECTIONS TO EXISTING BUILDINGS, ETC. WITHOUT INTERRUPTION UNLESS/UNTIL AUTHORIZED TO DISCONNECT BY THE OWNER, UTILITY COMPANIES, AND GOVERNING AUTHORITIES. THE CONTRACTOR SHALL INSTALL AS NECESSARY, TEMPORARY SITE LIGHTING, GAS, SANITARY, WATER, STORM, ELECTRIC, TELEPHONE, AND CABLE SERVICES TO SERVICE BUILDING(S) TO REMAIN OPEN. 14.CONTRACTOR TO PROVIDE SLEEVES UNDER FOOTINGS OR THROUGH FOUNDATIONS FOR UTILITY CONNECTIONS. 15.CONTRACTOR SHALL PROVIDE ALL BENDS, FITTINGS, ADAPTERS, ETC. AS REQUIRED FOR PIPE CONNECTIONS TO BUILDING/CANOPY STUB OUTS. INCLUDING ROOF/FOOTING DRAIN CONNECTIONS TO ROOF LEADERS AND TO STORM DRAINAGE SYSTEM. 16.CONTRACTOR SHALL CAP STUBS AND PROVIDE FIELD MARKERS. 17.CONTRACTOR TO PROVIDE AND INSTALL CONDUIT FOR SITE LIGHTING PER SITE LIGHTING PLAN (BY OTHERS). 18.CONTRACTOR TO PROVIDE AND INSTALL CONDUIT FOR IRRIGATION PER IRRIGATION PLAN (BY OTHERS). UTILITY NOTES W - WATER / FIRE PROTECTION S - SANITARY SEWER D - DRAINAGE / STORM SEWER D1 D2 D4 D3 6" PVC ROOF DRAIN COLLECTOR @ 1.04% MIN. SLOPE. 6" PVC SUB-SURFACE DRAIN @ 1.04% MIN. SLOPE; 4x10' STORM SEWER CLEANOUT D6 UNDERGROUND DETENTION PIPE (24") 92-LF OF 6" PVC SANITARY LATERAL @ 1.04% MIN. SLOPE.; CONNECT TO EXISTING LATERAL STUB CONNECT TO EXISTING WATER METER. CONNECT TO EXISTING WATER MAIN WITH TAPPING SLEEVE AND VALVE S1 S3 CORE AND CONNECT TO EXISTING MANHOLE. W1 W2 W3 8" WATER MAIN EXTENSION U - GENERAL UTILITY NOTE SAW-CUT, REMOVE, & REPAIR PAVEMENT, SIDEWALK, CURB FOR UTILITY INSTALLATIONU1 U2 UTILITY TO REMAIN ACTIVE OR IN SERVICE DURING DURATION OF CONSTRUCTION U3 UTILITY TO BE ABANDONED IN PLACE AFTER CONSTRUCTION HAS BEEN COMPLETED UTILITY KEY NOTE LEGEND 00 30'60' SCALE: 1" = 30' 8" WATER VALVEW4 STRUCTURE 12: MULTI STAGE OUTLET CONTROL STRUCTURE; SEE SHEET C602 FOR DETAILS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S SS SS SS S SS c.o. c.o. 49 . 0 ' 23.3' 7. 7 ' 72.8' 10 . 6 ' 9.4' 28 . 8 ' 8 . 1 ' 11 . 2 ' 5.4' 56 . 7 ' 11.4'3.4' 30 . 2 ' 12. 7 ' 11. 3 ' 5.3' 5.0 ' 57. 7 ' 4.9 ' 32. 7 ' 42. 0 ' 9.5 ' 37. 4 ' 3.4 '2.0 ' 61. 8 ' 40. 0 ' 95. 7 ' 35. 9 0 ' 35. 8 7 ' 18. 9 ' 26. 9 ' 77.7' 92 . 7 ' 9.3' 37 . 2 ' 5.4' 3. 5 ' 36.4' 23 . 4 ' 3.4' 20 . 2 ' 45.0'3.3' 19 . 9 ' 1 1 3 . 3 ' 23 . 3 ' 156.9' 13 1 . 5 ' 38.7' 33 . 8 ' 32.0' 1 1 7 . 1 ' 11.8' 4.0' 1.7'28.0' 6 7 5 8 6 7 5 8 SS SS SS SS SS SS SS SS H W S C W S R E T S SS SS SS SS SS STR. NO. 602A TC = 759.0 N 12" HDPE INV = 753.00 STR. EX-A 192 L. F. OF 1 2 " H D P E 52 L . F . O F 1 0 " H D P E 184 L. F. OF 1 2 " H D P E 12" H D P E 63 L . F . O F 1 2 " H D P E 70 L. F. OF 12" HDPE 54 L . F . O F PROPOSED B L D G . A D D I T I O N FFE = 760.1 6 STR. NO. 601 TC = 759.72 E 12" HDPE INV = 754.00 S 10" HDPE INV = 754.00 PEDESTRIAN CASTING NYOPLAST 12" DRAIN BASIN SOLID CASTING STR. NO. 602 TC = 759.80 S 12" HDPE INV = 752.65 N 12" HDPE INV = 752.63 OPEN CASTING W 12" HDPE INV = 752.75 STR. NO. 604 TC = 748.20 EX. N 15" PVC INV = 744.14 EX. S 15" PVC INV = 744.14 AQUA-SWIRL AS-4 SOLID CASTING NYOPLAST 12" DRAIN BASINNYOPLAST 12" DRAIN BASIN STR. NO. EX-C TC = 743.53 EX. N 15" PVC INV = 741.28 EX. E 18" PVC INV = 741.08 S S S S SS S c.o. c.o. STR. NO. 604 TC = 748.20 PROPOSED SANITARY MANHOLE INVERTS TO BE VERIFIED EX. N 21" HDPE INV = 741.25 Job No. Date:JANUARY 16, 2015 Scale: Sheet: FO R CO N S T R U C T I O N P L A N S RE V I S I O N S DA T E D E S C R I P T I O N MA R K CA R M E L , I N D I A N A PR E P A R E D B Y : Title: PR E P A R E D F O R : 14016L 83 6 5 K e y s t o n e C r o s s i n g , S u i t e 2 0 1 In d i a n a p o l i s , I N . 4 6 2 4 0 ( 3 1 7 ) 2 0 2 - 0 8 6 4 FOR REVIEW C501 SITE UTILITY PLAN DETAIL A: SANITARY LATERAL CONNECTION ENLARGEMENT SEE DETAIL "A", THIS SHEET SCALE: 1" = 20' POND OUTLET STRUCTURE IMPROVEMENTS SCALE: 1" = 40' EXISTING 12 INCH RCP PIPE INSTALL NEW END SECTION WITH TRASH/DEBRIS GUARD (2) 6" PVC LATERAL @ 1% MIN SLOPE CONNECT NEW CHILLER LINES TO EXISTING TAB 9 (BALLOT SHEET)FINDINGS OF FACT -SPECIAL USE CARMEL/CLAY BOARD OF ZONING APPEALS (Petitioner only fills out first 2 blanks) DocketNo. :_________________________ Petitioner:_________________________ 1.______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ 2._____________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ 3._____________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ 4._____________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ 5._____________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ 6._____________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ DATED THIS __________ DAY OF ______________________, 20 ____. _____________________________________ Board Member Page 9–filename: special use application 2014rev. 12/17/2013 TAB 10 CARMEL BOARD OF ZONING APPEALS Docket No.: 13040010 SU Petitioner: Harvest Bible Chapel of North Indianapolis, Inc. FINDING OF FACT – SPECIAL USE 1. The premises in question is particularly physically suitable for the proposed Special Use because: (i) the church and its related services are permitted special uses under the Neighborhood Residential District of the Legacy PUD, and are presumed to be appropriate uses, and (ii) the church is a complementary use to the surrounding open space and residential uses. 2. The Special Use will not injuriously or adversely affect economic factors, such as cost/benefit to the community and its anticipated effect on surrounding property values because: (i) this special use request would permit a use that is less intense than other potential uses that are permitted under the Neighborhood Residential District of the Legacy PUD, and (ii) the proposed church complements the surrounding open space and residential uses. 3. The Special Use will be consistent with social/neighborhood factors, such as compatibility with existing uses and those permitted under current zoning in the vicinity of the premises under consideration and how the proposed Special Use will affect neighborhood integrity because: the surrounding areas also are zoned Neighborhood Residential and Open Space, and, therefore, the special use would be compatible with existing uses permitted in the vicinity and also provide a benefit due to the related services offered by the church. 4. The Special Use will not injuriously or adversely affect the adequacy and availability of water, sewage and storm drainage facilities and police and fire protection because: the proposed special use would have a nominal impact on water, sewage, storm drainage facilities, and police and fire protection in the area, all of which are already available. 5. The Special Use will not adversely affect vehicular and pedestrian traffic in and around the premises upon which the Special Use is proposed because: (i) worship services will occur during non-peak hours and there will be a limited impact on vehicular traffic in the vicinity, and (ii) there will be a positive impact on pedestrian traffic through the addition of pedestrian paths. DECISION IT IS THEREFORE the decision of the Carmel Board of Zoning Appeals that the Special Use Docket No. 13040010SU is granted, subject to any conditions stated in the minutes of this Board, and set forth below which are incorporated herein by reference and made a part hereof. ADOPTED this 24th day of June, 2013. _____________________________________________ CHAIRPERSON, Carmel/Clay Board of Zoning Appeals _____________________________________________ SECRETARY, Carmel/Clay Board of Zoning Appeals