Loading...
HomeMy WebLinkAbout1 Title Sheet.pdfCarmel, Indiana 580 East Carmel Drive DRAWING SHEET INDEX GENERAL NOTESSCOPE DOCUMENT PR O J E C T T I T L E S H E E T TS TM K TR S NORTH NO SCALE VICINITY MAP THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE TYPE OF STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED. THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 1.DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 2.ALL WORK MUST COMPLY WITH APPLICABLE LOCAL AND STATE CODES AND FEDERAL LAWS. 3.THIS PROJECT IS DESIGNED AND DOCUMENTED PER THE ARCHITECT'S INTERPRETATION OF THE CODE REQUIREMENTS. VARIOUS GOVERNING AGENCIES SOMETIMES INTERPRET CODES, LAWS, AND ORDINANCES DIFFERENTLY. THESE AGENCIES HAVE JURISDICTION TO REQUIRE CHANGES IN DESIGN AND CONSTRUCTION. ANY CHANGES OR MODIFICATIONS TO THE DESIGN MAY NECESSITATE PRICE ADJUSTMENTS. 4.VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DIMENSIONAL CONFLICTS OR CONFLICTS DUE TO UNKNOWN CONDITIONS. WORK SHALL NOT PROCEED UNTIL CONFLICTS ARE RESOLVED. 5.EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. 6.REVIEW ALL DRAWINGS (ARCHITECTURAL, HVAC, PLUMBING, ELECTRICAL) CONCERNING SLEEVES, OUTLETS, BOXES, ANCHORS, VENTS, OPENINGS, ETC. THAT MAY BE REQUIRED. EACH RESPECTIVE TRADE IS RESPONSIBLE FOR PROVIDING EQUIPMENT REQUIRED FOR A COMPLETE SYSTEM. 7.THE ERRORS AND OMISSIONS DESIGN LIABILITY FOR THE PROJECT SHALL BE LIMITED TO THE DESIGN COST OF CORRECTING THE DEFICIENCY. 8.CONTRACTOR TO PROVIDE AND INSTALL ANY MISCELLANEOUS BLOCKING AS REQUIRED FOR ANY WALL MOUNTED SHELVING, EQUIPMENT, OR ACCESSORIES. 9.EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, DUST PARTITIONS, FLOOR PROTECTION, ETC. AS REQUIRED BY LAW OR AS OTHERWISE REQUIRED. 10.EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, PALLETS, PACKAGING, UNUSED MATERIALS, TRASH, AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE. 11.ONSITE RESTROOMS ARE NOT TO BE USED BY CONTRACTORS. TEMPORARY FACILITIES SHALL BE PROVIDED BY THE G.C. 12.CONTRACTOR IS RESPONSIBLE FOR STRUCTURAL DESIGN AND CALCULATIONS OF EXTERIOR WALLS. WALLS SHALL BE DESIGNED PER IBC 2006 BASED ON AXIAL WIND LOADS AND SUPPORT OF COMPLETE WALL SYSTEM. 13.GENERAL CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR COORDINATION BETWEEN OWNER AND SUBCONTRACTORS/SUPPLIERS FOR SELECTION OF ALL BUILDING MATERIALS AND FINISHES REQUIRED FOR COMPLETE BUILDING SYSTEMS TO MEET MINIMUM REQUIREMENTS AS SHOWN IN THIS SET OF PLANS, CURRENT INDUSTRY STANDARDS, AND APPLICABLE CODES. 14.GENERAL CONTRACTOR SHALL BE RESPONSIBLE SHOP DRAWING SUBMITTALS, REVIEW AND APPROVAL. Q UA N T U M AR C H I T E C T U R E PO B o x 5 6 0 3 2 I n d i a n a p o l i s , I N 4 6 2 5 6 31 7 - 4 1 3 - 9 4 9 7 w w w . q - a r c h i t e c t u r e . c o m Oc t 3 1 , 2 0 1 4 13 0 0 5 a 58 0 E a s t C a r m e l D r i v e Ca r m e l , I n d i a n a ARCHITECTURE MECH /ELECT Q UANTUM ARCHITECTURE PO Box 56032 Indianapolis, IN 46256 317-413-9497 www.q-architecture.com STRUCTURAL CONSTRUCTION MANAGEMENT 14351 Quail Pointe Drive Carmel, Indiana 46032 Phone (317) 844-7514 ajobs@ajassociatespc.com CIVIL TS TITLE SHEET LS LIFE SAFETY PLAN CIVIL C001 CIVIL TITLE SHEET C100 SITE PREPARATION AND SWPPP1 C101 STORM WATER POLLUTION PREVENTION II C102 STORM WATER POLLUTION PREVENTION PLAN II C103 SWPPP PHASE 1 DETAILS C104 SWPPP PHASE 2 DETAILS C200 SITE PLAN C201 SITE PLAN DETAILS C300 GRADING PLAN C301 FLOOD ROUTING C302 GRADING AND DRAINAGE DETAILS C500 SANITARY LATERAL PLAN AND PROFILE C600 PLAN AND PROFILE C601 PLAN AND PROFILE C800 UTILITY PLAN C801 UTILITY DETAILS C802 UTILITY DETAILS C900 PROJECT SPECIFICATIONS C901 CARMEL CURB AND PAVING POLICY L101 LANDSCAPE PLAN L102 LANDSCAPE DETAILS STRUCTURAL S1.0 STRUCTURAL GENERAL NOTES S1.1 FOUNDATION PLAN S1.2 2nd FLOOR FRAMING PLAN S1.3 3rd FLOOR FRAMING PLAN S1.4 4th FLOOR FRAMING PLAN S1.5 ROOF FRAMING PLAN S1.6 PARAPET FRAMING PLAN S2.1 BRACING ELEVATIONS S2.2 FRAMING ELEVATIONS S3.1 FOUNDATION SECTIONS S3.2 FRAMING SECTIONS S3.3 FRAMING SECTIONS S3.4 FRAMING SECTIONS S3.5 FRAMING SECTIONS ARCHITECTURAL A1.1 1st FLOOR PLAN A1.2 2nd FLOOR PLAN A1.3 3rd FLOOR PLAN A1.4 4th FLOOR PLAN A1.5 ROOF PLAN A2.1 1st FLOOR REFLECTED CEILING PLAN A2.2 2nd FLOOR REFLECTED CEILING PLAN A2.3 3rd FLOOR REFLECTED CEILING PLAN A2.4 4th FLOOR REFLECTED CEILING PLAN A3.1 EXTERIOR ELEVATIONS A3.2 EXTERIOR ELEVATIONS A4.1 BUILDING SECTIONS A4.2 BUILDING SECTIONS A4.3 BUILDING SECTIONS A4.4 BUILDING SECTIONS A5.1 ENLARGED RESTROOM PLANS A5.2 STAIR DETAILS A5.3 ARCHITECTURAL DETAILS A5.4 ARCHITECTURAL DETAILS A6.1 DOOR SCHEDULE AND DETAILS A6.2 WINDOW SCHEDULE AND DETAILS A6.3 ROOM FINISH SCHEDULE HVAC M0.1 HVAC SYMBOLS AND ABBREVIATIONS M0.2 HVAC SPECIFICATIONS M0.3 HVAC SPECIFICATIONS (CONT'D) M1.1 1st FLOOR HVAC PLAN M1.2 2nd FLOOR HVAC PLAN M1.3 3rd FLOOR HVAC PLAN M1.4 4th FLOOR HVAC PLAN M1.5 ROOF HVAC PLAN M5.1 HVAC SCHEDULES M6.1 HVAC DETAILS PLUMBING P0.1 PLUMBING SYMBOLS AND ABBREVIATIONS P1.0 FOUNDATION PLUMBING PLAN P1.1 1st FLOOR PLUMBING PLAN P1.2 2nd FLOOR PLUMBING PLAN P1.3 3rd FLOOR PLUMBING PLAN P1.4 4th FLOOR PLUMBING PLAN P1.5 ROOF PLUMBING PLAN P4.1 PLUMBING RISER DIAGRAMS P5.1 PLUMBING DETAILS P6.1 PLUMBING SCHEDULES ELECTRICAL E1.0 ELECTRICAL SITE PLAN E1.1 1st FLOOR LIGHTING PLAN E1.2 2nd FLOOR LIGHTING PLAN E1.3 3rd FLOOR LIGHTING PLAN E1.4 4th FLOOR LIGHTING PLAN E2.1 1st FLOOR POWER PLAN E2.2 2nd FLOOR POWER PLAN E2.3 3rd FLOOR POWER PLAN E2.4 4th FLOOR POWER PLAN E2.5 ROOF ELECTRICAL PLAN E5.1 SINGLE LINE RISER DIAGRAM E5.2 ELECTRICAL SCHEDULES E5.3 ELECTRICAL SCHEDULES PROJECT LOCATION 580 East Carmel Drive Carmel, Indiana OFFICE BUILDING 201 N. Delaware Street, Suite C Indianapolis, Indiana 46204 Phone: 1.317.927.8307 www.genesis-engineering.com