HomeMy WebLinkAbout1 Title Sheet.pdfCarmel, Indiana
580 East Carmel Drive
DRAWING SHEET INDEX
GENERAL NOTESSCOPE DOCUMENT
PR
O
J
E
C
T
T
I
T
L
E
S
H
E
E
T
TS
TM
K
TR
S
NORTH NO SCALE
VICINITY MAP
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS, AND
THE TYPE OF STRUCTURAL,
MECHANICAL, AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK
REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED. THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.
1.DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.
2.ALL WORK MUST COMPLY WITH APPLICABLE LOCAL AND
STATE CODES AND FEDERAL LAWS.
3.THIS PROJECT IS DESIGNED AND DOCUMENTED PER THE
ARCHITECT'S INTERPRETATION OF THE CODE
REQUIREMENTS. VARIOUS GOVERNING AGENCIES
SOMETIMES INTERPRET CODES, LAWS, AND ORDINANCES
DIFFERENTLY. THESE AGENCIES HAVE JURISDICTION TO
REQUIRE CHANGES IN DESIGN AND CONSTRUCTION.
ANY CHANGES OR MODIFICATIONS TO THE DESIGN MAY
NECESSITATE PRICE ADJUSTMENTS.
4.VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START
OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY
OF ANY DIMENSIONAL CONFLICTS OR CONFLICTS DUE
TO UNKNOWN CONDITIONS. WORK SHALL NOT
PROCEED UNTIL CONFLICTS ARE RESOLVED.
5.EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING
SHEETS TO DETERMINE FULL EXTENT OF
RESPONSIBILITIES FOR EACH RESPECTIVE TRADE.
6.REVIEW ALL DRAWINGS (ARCHITECTURAL, HVAC,
PLUMBING, ELECTRICAL) CONCERNING SLEEVES,
OUTLETS, BOXES, ANCHORS, VENTS, OPENINGS, ETC.
THAT MAY BE REQUIRED. EACH RESPECTIVE TRADE IS
RESPONSIBLE FOR PROVIDING EQUIPMENT REQUIRED
FOR A COMPLETE SYSTEM.
7.THE ERRORS AND OMISSIONS DESIGN LIABILITY FOR THE
PROJECT SHALL BE LIMITED TO THE DESIGN COST OF
CORRECTING THE DEFICIENCY.
8.CONTRACTOR TO PROVIDE AND INSTALL ANY
MISCELLANEOUS BLOCKING AS REQUIRED FOR ANY
WALL MOUNTED SHELVING, EQUIPMENT, OR
ACCESSORIES.
9.EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES,
DUST PARTITIONS, FLOOR PROTECTION, ETC. AS
REQUIRED BY LAW OR AS OTHERWISE REQUIRED.
10.EACH CONTRACTOR IS REQUIRED TO REMOVE ALL
CARTONS, BOXES, PALLETS, PACKAGING, UNUSED
MATERIALS, TRASH, AND DEBRIS CAUSED BY HIS WORK
FROM THE JOB SITE.
11.ONSITE RESTROOMS ARE NOT TO BE USED BY
CONTRACTORS. TEMPORARY FACILITIES SHALL BE
PROVIDED BY THE G.C.
12.CONTRACTOR IS RESPONSIBLE FOR STRUCTURAL DESIGN
AND CALCULATIONS OF EXTERIOR WALLS. WALLS SHALL
BE DESIGNED PER IBC 2006 BASED ON AXIAL WIND
LOADS AND SUPPORT OF COMPLETE WALL SYSTEM.
13.GENERAL CONTRACTOR SHALL BE FULLY RESPONSIBLE
FOR COORDINATION BETWEEN OWNER AND
SUBCONTRACTORS/SUPPLIERS FOR SELECTION OF ALL
BUILDING MATERIALS AND FINISHES REQUIRED FOR
COMPLETE BUILDING SYSTEMS TO MEET MINIMUM
REQUIREMENTS AS SHOWN IN THIS SET OF PLANS,
CURRENT INDUSTRY STANDARDS, AND APPLICABLE
CODES.
14.GENERAL CONTRACTOR SHALL BE RESPONSIBLE SHOP
DRAWING SUBMITTALS, REVIEW AND APPROVAL.
Q
UA
N
T
U
M
AR
C
H
I
T
E
C
T
U
R
E
PO
B
o
x
5
6
0
3
2
I
n
d
i
a
n
a
p
o
l
i
s
,
I
N
4
6
2
5
6
31
7
-
4
1
3
-
9
4
9
7
w
w
w
.
q
-
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
Oc
t
3
1
,
2
0
1
4
13
0
0
5
a
58
0
E
a
s
t
C
a
r
m
e
l
D
r
i
v
e
Ca
r
m
e
l
,
I
n
d
i
a
n
a
ARCHITECTURE MECH /ELECT
Q UANTUM
ARCHITECTURE
PO Box 56032 Indianapolis, IN 46256
317-413-9497 www.q-architecture.com
STRUCTURAL CONSTRUCTION
MANAGEMENT
14351 Quail Pointe Drive
Carmel, Indiana 46032
Phone (317) 844-7514
ajobs@ajassociatespc.com
CIVIL
TS TITLE SHEET
LS LIFE SAFETY PLAN
CIVIL
C001 CIVIL TITLE SHEET
C100 SITE PREPARATION AND SWPPP1
C101 STORM WATER POLLUTION PREVENTION II
C102 STORM WATER POLLUTION PREVENTION PLAN II
C103 SWPPP PHASE 1 DETAILS
C104 SWPPP PHASE 2 DETAILS
C200 SITE PLAN
C201 SITE PLAN DETAILS
C300 GRADING PLAN
C301 FLOOD ROUTING
C302 GRADING AND DRAINAGE DETAILS
C500 SANITARY LATERAL PLAN AND PROFILE
C600 PLAN AND PROFILE
C601 PLAN AND PROFILE
C800 UTILITY PLAN
C801 UTILITY DETAILS
C802 UTILITY DETAILS
C900 PROJECT SPECIFICATIONS
C901 CARMEL CURB AND PAVING POLICY
L101 LANDSCAPE PLAN
L102 LANDSCAPE DETAILS
STRUCTURAL
S1.0 STRUCTURAL GENERAL NOTES
S1.1 FOUNDATION PLAN
S1.2 2nd FLOOR FRAMING PLAN
S1.3 3rd FLOOR FRAMING PLAN
S1.4 4th FLOOR FRAMING PLAN
S1.5 ROOF FRAMING PLAN
S1.6 PARAPET FRAMING PLAN
S2.1 BRACING ELEVATIONS
S2.2 FRAMING ELEVATIONS
S3.1 FOUNDATION SECTIONS
S3.2 FRAMING SECTIONS
S3.3 FRAMING SECTIONS
S3.4 FRAMING SECTIONS
S3.5 FRAMING SECTIONS
ARCHITECTURAL
A1.1 1st FLOOR PLAN
A1.2 2nd FLOOR PLAN
A1.3 3rd FLOOR PLAN
A1.4 4th FLOOR PLAN
A1.5 ROOF PLAN
A2.1 1st FLOOR REFLECTED CEILING PLAN
A2.2 2nd FLOOR REFLECTED CEILING PLAN
A2.3 3rd FLOOR REFLECTED CEILING PLAN
A2.4 4th FLOOR REFLECTED CEILING PLAN
A3.1 EXTERIOR ELEVATIONS
A3.2 EXTERIOR ELEVATIONS
A4.1 BUILDING SECTIONS
A4.2 BUILDING SECTIONS
A4.3 BUILDING SECTIONS
A4.4 BUILDING SECTIONS
A5.1 ENLARGED RESTROOM PLANS
A5.2 STAIR DETAILS
A5.3 ARCHITECTURAL DETAILS
A5.4 ARCHITECTURAL DETAILS
A6.1 DOOR SCHEDULE AND DETAILS
A6.2 WINDOW SCHEDULE AND DETAILS
A6.3 ROOM FINISH SCHEDULE
HVAC
M0.1 HVAC SYMBOLS AND ABBREVIATIONS
M0.2 HVAC SPECIFICATIONS
M0.3 HVAC SPECIFICATIONS (CONT'D)
M1.1 1st FLOOR HVAC PLAN
M1.2 2nd FLOOR HVAC PLAN
M1.3 3rd FLOOR HVAC PLAN
M1.4 4th FLOOR HVAC PLAN
M1.5 ROOF HVAC PLAN
M5.1 HVAC SCHEDULES
M6.1 HVAC DETAILS
PLUMBING
P0.1 PLUMBING SYMBOLS AND ABBREVIATIONS
P1.0 FOUNDATION PLUMBING PLAN
P1.1 1st FLOOR PLUMBING PLAN
P1.2 2nd FLOOR PLUMBING PLAN
P1.3 3rd FLOOR PLUMBING PLAN
P1.4 4th FLOOR PLUMBING PLAN
P1.5 ROOF PLUMBING PLAN
P4.1 PLUMBING RISER DIAGRAMS
P5.1 PLUMBING DETAILS
P6.1 PLUMBING SCHEDULES
ELECTRICAL
E1.0 ELECTRICAL SITE PLAN
E1.1 1st FLOOR LIGHTING PLAN
E1.2 2nd FLOOR LIGHTING PLAN
E1.3 3rd FLOOR LIGHTING PLAN
E1.4 4th FLOOR LIGHTING PLAN
E2.1 1st FLOOR POWER PLAN
E2.2 2nd FLOOR POWER PLAN
E2.3 3rd FLOOR POWER PLAN
E2.4 4th FLOOR POWER PLAN
E2.5 ROOF ELECTRICAL PLAN
E5.1 SINGLE LINE RISER DIAGRAM
E5.2 ELECTRICAL SCHEDULES
E5.3 ELECTRICAL SCHEDULES
PROJECT LOCATION
580 East Carmel Drive
Carmel, Indiana
OFFICE
BUILDING
201 N. Delaware Street, Suite C
Indianapolis, Indiana 46204
Phone: 1.317.927.8307
www.genesis-engineering.com