Loading...
HomeMy WebLinkAboutA010-5.pdfXX DIMENSION PLAN SYMBOLS NEW COLUMN LINE DETAIL INDICATOR AREA OF DETAIL DETAIL NUMBER SHEET NUMBER ROOM NAME DESIGNATION ROOM NUMBER DESIGNATION PLAN NOTE DESIGNATION DOOR NUMBER DESIGNATION FLOOR DRAIN CURTAIN TRACK W/ CURTAIN F.D. A101 1 SIM SIMILAR ROOM 000 10 1 1 XX EXISTING COLUMN LINE H. O . AU T O NEW DOOR NEW WALL DOOR WITH MAGNETIC HOLD OPEN DEVICES DOOR WITH AUTOMATIC DOOR OPERATOR NEW DOOR NEW WALL PUSH PLATE FOR AUTO DOOR OPERATOR CARD READER FOR ELECTRIC DOOR LATCH KEYPAD FOR ELECTRIC DOOR LATCH PROXIMITY SENSOR TOUCHLESS ACTUATOR CR PP TA PS KP 2-HOUR RATED FIRE BARRIER- 2H WALL RATINGS GENERAL DIM. PLAN NOTES 3-HOUR RATED FIRE BARRIER- 3H 1-HOUR RATED FIRE BARRIER- 1H C. ALL INTERIOR GYPSUM DRYWALL WALLS SHALL BE TYPE 'B3' UNLESS NOTED OTHERWISE. D. E. ALL DIMENSIONS ARE TO CENTER OF COLUMN LINES, FACE OF DRYWALL OR TO FACE OF EXISTING WALL FINISH, UNLESS NOTED OTHERWISE. REFER TO 'IF' SHEET SERIES FOR ADDITIONAL INTERIOR FINISH INFORMATION. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL FOR ADDITIONAL INFORMATION. F. G. ALL INTERIOR GYPSUM DRYWALL COLUMN SURROUNDS SHALL BE WALL TYPE 'A2' UNLESS NOTED OTHERWISE. H. CONTRACTOR SHALL VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. A. B. REFER TO SHEET A500.5 FOR OPENING SCHEDULE AND TYPICAL INTERIOR DOOR OPENING DETAILS. REFER TO SHEET A010.5 FOR WALL TYPES. PROVIDE 5/8" GYPSUM DRYWALL ON INSIDE OF ALL TENANT SPACE WALLS. GYPSUM DRYWALL TO BE FOIL FACED AT ALL EXTERIOR WALL LOCATIONS. I. ALL COLUMN SURROUNDS SHALL BE 1'-0" FROM CENTERLINE OF COLUMN TO EXTERIOR FACE OF DRYWALL IN ALL DIRECTIONS, UNLESS NOTED OTHERWISE. J. WALL TYPE WALL TYPE SUFFIX XX.# DOOR FRAMES SHALL BE TYPICALLY 6" FROM PERPENDICULAR CORNER TO DOOR OPENING (INSIDE OF FRAME), ULESS NOTED OTHERWISE. K. 1 A000 2 3 4 XX ARCH. PLAN SYMBOLS NEW COLUMN LINE DETAIL INDICATOR AREA OF DETAIL DETAIL NUMBER SHEET NUMBER ROOM NAME DESIGNATION ROOM NUMBER DESIGNATION PLAN NOTE DESIGNATION EQUIPMENT DESIGNATION. REFER TO EQUIPMENT SCHEDULE. ELEVATION TAG CURTAIN TRACK W/ CURTAIN GENERAL ARCH. PLAN NOTES A. B. A101 1 SIM SIMILAR 000 ROOM 000 1 REFER TO SHEET A010.5 FOR TOILET ACCESSORIES SCHEDULE. PAINTING CONTRACTOR SHALL LABEL, ABOVE CEILING, ALL FIRE RATED WALL CONSTRUCTION AND SMOKE BARRIER WALL CONSTRUCTION IN ACCORDANCE WITH SPECIFICATION. C. REFER TO SHEET A010.5 FOR EQUIPMENT SCHEDULE. REFER TO M/E/P DRAWINGS TO COORDINATE CONNECTIONS. XX EXISTING COLUMN LINE D. ALL FURNITURE SHOWN FOR REFERENCE ONLY. E. REFER TO INTERIOR FINISH PLANS FOR LOCATIONS OF HANDRAILS, BUMPRAILS, CORNER GUARDS, AND WALL PROTECTION. TOILET ACCESSORY NOTE DESIGNATION 1 F. REFER TO INTERIOR FINISH PLANS FOR WINDOW SHADE TYPES AND LOCATIONS. G. PROVIDE (2) COAT HOOKS CENTERED ON BACK SIDE OF DOOR IN EACH FITTING ROOM. ALL COAT HOOKS TO BE MOUNTED AT 5'-6" A.F.F. GENERAL RC PLAN NOTES A. ALL LAY-IN ACOUSTICAL CEILINGS SHALL BE INSTALLED AT 9'-0" ABOVE FINISH FLOOR, UNLESS NOTED OTHERWISE. B. REF. CEILING PLAN SYMBOLS ACT - 1 SUSPENDED LAY-IN CEILING SYSTEM RECESSED "CAN" TYPE LIGHT FIXTURE OR PENDANT CEILING MOUNTED EXIT LIGHT CUBICLE CURTAIN TRACK AND CURTAIN 2'x4' LIGHTING FIXTURE 2'x2' LIGHTING FIXTURE RETURN AIR GRILLE SUPPLY AIR GRILLE SUPPLY AIR GRILLE CEILING HEIGHT ABOVE FINISH FLOOR DRYWALL BULKHEAD/CEILING 1'x4' LIGHTING FIXTURE ACOUSTICAL CEILING TILE - TYPE EXHAUST AIR GRILLE +9'-0" LOBBY LIGHT FIXTURE (EXISTING) CHAIN HUNG LIGHT FIXTURE ALL LAY-IN ACOUSTICAL CEILINGS SHALL BE TYPE 3, UNLESS NOTED OTHERWISE. C. ALL GYPSUM DRYWALL BULKHEADS SHALL BE INSTALLED AT 8'-6" ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. ALL GYPSUM DRYWALL BULKHEADS ABOVE CASEWORK SHALL BE INSTALLED AT 7'-2" ABOVE FINISHED FLOOR. D. REFER TO INTERIOR FINISH PLANS FOR GYPSUM DRYWALL BULKHEAD FINISHES. E. FIRE RATINGS NOT SHOWN ON REFLECTED CEILING PLANS. REFER TO LIFE SAFETY PLANS OR DIMENSION PLANS FOR WALL RATING LOCATIONS. F. CAN LIGHTS WITHIN GYPSUM DRYWALL BULKHEADS SHALL BE INSTALLED AT CENTERLINE OF BULKHEAD WIDTH. INT. ELEV. SYMBOL LEGEND GENERAL INT. ELEV. NOTES A. REFER TO SHEET A010.5 FOR THE EQUIPMENT LIST AND TOILET ACCESSORIES SCHEDULE. REFER TO M/E/P DRAWINGS TO COORDINATE CONNECTIONS C. ALL DIMENSIONS ARE TAKEN TO THE FACE OF FINISHED MATERIAL. D. COORDINATE BULKHEAD HEIGHTS INDICATED ON INTERIOR ELEVATIONS WITH THAT SHOWN ON THE REFLECTED CEILING PLAN. CONFIRM ANY DISCREPANCIES WITH THE ARCHITECT PRIOR TO CONSTRUCTION. E. PROVIDE A 4" HIGH INTEGRAL BACK SPLASH ON ALL COUNTERS WITH RECESSED SINKS. INSTALL SIDE SPLASHES WHERE THESE COUNTERS ABUT A WALL, UNLESS NOTED OTHERWISE. F. PROVIDE ADJUSTABLE SHELVING WITHIN ALL WALL AND BASE CABINETRY AS SHOWN BY DASHED LINE. G. PROVIDE 12" CLEAR INTERIOR DIMENSION ON ALL UPPER WALL CABINETS UNLESS NOTED OTHERWISE. H. COORDINATE ALL WALL OUTLETS TO AVOID CONFLICT WITH CASEWORK. I. INSTALL WOOD BLOCKING TO STUDS TO SUPPORT ALL WALL-MOUNTED CABINETRY AND EQUIPMENT AS REQUIRED. J. ALL CASEWORK SHALL BE FINISHED WOOD UNLESS NOTED OTHERWISE. K. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTING CABINETRY. L. PROVIDE FILLER PANELS AT ALL LOCATIONS WHERE CABINETRY ABUTS A WALL. ALL BASE CABINETS SHALL BE 2'-0" DEEP UNLESS NOTED OTHERWISE. XX NEW COLUMN LINE SECTION INDICATOR DETAIL INDICATOR AREA OF DETAIL DETAIL NUMBER SHEET NUMBER ELEVATION NOTE DESIGNATION A101 1 SIM SIMILAR 1 A101 SIM 1 TOILET ACCESSORY # B. ABBREVIATION LIST A.F.F. ABOVE FINISHED FLOOR ALT. ALTERNATE ALUM. ALUMINUM APP. APPLICABLE ARCH. ARCHITECTURAL AXON. AXONOMETRIC DRAWING B.C. BRICK COURSE / BRICK COURSES B.O. BOTTOM OF CL. CENTERLINE CLR. CLEAR C.M.U. CONCRETE MASONRY UNIT CONFIG. CONFIGURATION CONT. CONTINUOUS / CONTINUED C.F.C.I. CONTRACTOR FURNISHED, CONTRACTOR INSTALLED C.J. CONTROL JOINT DIMS. DIMENSIONS E.J. EXPANSION JOINT AT BRICK VENEER ELEC. ELECTRICAL ELEV. ELEVATION EQ. EQUAL E.W.C. ELECTRIC WATER COOLER EXT. EXTERIOR F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET F.R.T. FIRE RETARDANT TREATED GA. GAUGE GALV. GALVANIZED G.S.F. GROSS SQUARE FEET GYP. GYPSUM HORIZ. HORIZONTAL / HORIZONTALLY INT. INTERIOR L.C.C. LEAD COATED COPPER JT. JOINT MAX. MAXIMUM MECH. MECHANICAL / MECHANICALLY MER. MOLDED EPOXY RESIN MFGR. MANUFACTURER/S MIN. MINIMUM M.O. MASONRY OPENING O.C. ON CENTER O.H. OPPOSITE HAND O.F.O.I. OWNER FURNISHED, OWNER INSTALLED O.F.C.I. OWNER FURNISHED, CONTRACTOR INSTALLED P. PLASTIC RAD./R/ RADIUS REF. REFER / REFERENCE R.O. ROUGH OPENING SIM. SIMILIAR S.F. SQUARE FEET S.S. STAINLESS STEEL S.S.G. STRUCTURAL SILICON GLAZED STRUC. STRUCTURAL T.O. TOP OF U.N.O. UNLESS NOTED OTHERWISE V. VARIES VERT. VERTICAL / VERTICALLY V.I.F. VERIFY IN FIELD W/ WITH DIAMETER GENERAL WALL TYPE NOTES A. DIMENSIONS IN PLAN AND ELEVATION ARE TAKEN TO THE FACE OF FINISH DRYWALL OR CENTER LINE OF COLUMN, UNLESS NOTED OTHERWISE. B. ALL INTERIOR WALLS SHALL BE TYPE 'B3' UNLESS NOTED OTHERWISE. ALL COLUMN SURROUNDS SHALL BE WALL TYPE 'A2' UNLESS NOTED OTHERWISE. C. PROVIDE FULL HEIGHT STRUCTURAL STUDS TO THE STRUCTURE ABOVE AT ALL CORNERS, AT DOOR AND BORROWED LIGHT FRAMES, JAMBS, AND BEHIND ALL WALL MOUNTED EQUIPMENT AND/ OR CASEWORK. D. FURNISH AND INSTALL FIRE STOP SEALANT WHERE GYPSUM WALL BOARD MEETS FIREPROOFING ON COLUMNS, BEAMS, AND METAL DECK AT FIRE RATED PARTITIONS. E. ALL PENETRATIONS THROUGH FIRE AND SMOKE RATED WALLS SHALL BE FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS. F. AT FIRE RATED WALLS, PROVIDE TESTED FIRE STOPPING SYSTEM AT HEAD OF WALL. AT ALL NON-FIRE RATED WALLS, INCLUDING SOUND RESISITANT WALLS, SMOKE PARTITIONS AND CORRIDOR WALLS, PACK VOID SPACE BETWEEN METAL DECK FLUTES AND TOP OF PARTITION WITH FIRE SAFING AND SEAL GAP AT DRYWALL WITH ACOUSTICAL SEALANT. G. ALL WALLS SHALL BE TREATED AS SOUND RESISTANT WALLS (UNLESS NOTED OTHERWISE). SEAL AROUND ALL PENETRATIONS AND INSTALL SOUND ATTENTION BATTS FULL HEIGHT. FIT INSULATION TIGHT AROUND DUCT AND PIPE PENETRATIONS. ALL SOUND RESISTANT WALLS WITH SOUND ATTENUATION BATTS SHALL HAVE ACOUSTICAL SEALANT UNDER BOTTOM RUNNER TRACK. H. ALL STUDS SHALL BE AT 16" O.C. UNLESS NOTED OTHERWISE. 1. INDICATES ENTIRE WALL CONSTRUCTION TO STOP 6" ABOVE FINISHED CEILING. 2. INDICATES GYPSUM BOARD ON ONE SIDE TO STOP 6" ABOVE FINISHED CEILING. 3. INDICATES PARTIAL HEIGHT WALL. a. INDICATES NO SOUND ATTENUATION BLANKETS b. INDICATES ADDITIONAL LAYER OF 5/8" GYPSUM BOARD OVER WALL. c. INDICATES FOIL-FACED GYPSUM BOARD. WALL TYPE SYMBOL X1.1x INDICATES CONSTRUCTION TYPE NUMERICAL INDICATION OF STUD/MASONRY SIZE SUFFIX INDICATES MODIFICATIONS TO WALL CONSTRUCTION HEIGHT SUFFIX INDICATES HORIZONTAL MODIFICATIONS WALL TYPES SUFFIX Ax WALL PARTITION 1 1/2" = 1'-0" BASE SECTION PLAN SECTION HEAD SECTION Bx WALL PARTITION 1 1/2" = 1'-0" BASE SECTION PLAN SECTION HEAD SECTION Fx WALL PARTITION 1 1/2" = 1'-0" BASE SECTION PLAN SECTION HEAD SECTION 01 TYP. METAL STUD PARTITION HEAD DETAIL 1 1/2" = 1'-0" NON-BEARING PARALLEL TO RIBS OF DECK PERPENDICULAR TO RIBS OF DECK Dx WALL PARTITION 1 1/2" = 1'-0" BASE SECTION PLAN SECTION HEAD SECTION AX-'X'=METAL STUD SIZE A2-2 1/2" METAL STUDS A3-3 5/8" METAL STUDS A6-6" METAL STUDS BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE STEEL STUD RUNNER TRACK. STUDS SCREWED AT BOTTOM FLOOR SLAB 5/8" GYPSUM WALL BOARD METAL STUDS (REFER TO CHART BELOW) DEFLECTION TRACK BOTTOM OF STRUCTURE FASTEN GYPSUM BOARD TO STUDS NOT TO THE TOP TRACK BX-'X'=METAL STUD SIZE B2-2 1/2" METAL STUDS B3-3 5/8" METAL STUDS B6-6" METAL STUDS BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE (FIRESTOP AT RATED PARTITIONS) FLOOR SLAB STEEL STUD RUNNER TRACK. STUDS SCREWED ON EA. SIDE AT BOTTOM BOTTOM OF STRUCTURE 1/2" SEALANT SPACE (FIRESTOP SYSTEM AT RATED PARTITIONS) DEFLECTION TRACK FASTEN GYPSUM BOARD TO STUDS NOT TO THE TOP TRACK METAL STUDS (REFER TO CHART BELOW) 1/2" SEALANT SPACE BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 5/8" GYPSUM WALL BOARD 1/2" SEALANT SPACE FLOOR SLAB 5/8" GYPSUM BOARD FURRING CHANNEL (REFER TO CHART BELOW) ADJACENT WALL CONSTRUCTION BOTTOM OF STRUCTURE FINISH CEILING. REFER TO REFLECTED CEILING PLAN. NON-RATED NON-RATED 1 HOUR RATED PARTITION; UL #V450 (WHERE NOTED ON PLAN) SOUND ATTENUATION BATTS SOUND ATTENUATION BATTS METAL DECK. REFER TO STRUCTURAL DRAWINGS. METAL EDGE TRIM WHERE EXPOSED TO VIEW. FASTEN STEEL RUNNER TO METAL DECK. FRICTION FIT METAL STUDS TO DEFLECTION TRACK AND FASTEN GYPSUM BOARD TO STUDS. DO NOT FASTEN TO DEFLECTION TRACK. MAINTAIN GAP BETWEEN STEEL DEFLECTION TRACK AND METAL STUD/GYPSUM BOARD TO ACCOMMODATE STRUCTURAL DEFLECTION. COMPRESSED SAFING INSULATION. (FIRESTOPPING AT RATED PARTITIONS) STEEL RUNNER WITH MIN. 2" FLANGES CONTINUOUS ACOUSTIC SEALANT BOTH SIDES. (FIRESTOPPING AT RATED PARTITIONS) REFER TO PARTITION TYPES FOR WALL CONSTRUCTION. D1- 1 5/8" STUD D2- 2 1/2" STUD D3- 3 5/8" STUD D4- 4" STUD D5- 6" STUD BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE FLOOR SLAB 5/8" GYPSUM BOARD METAL STUDS (REFER TO CHART BELOW) BOTTOM OF STRUCTURE NON-RATED WALL 1/8" ALIGNMENT SPACE (IF APPLICABLE) ADJACENT WALL CONSTRUCTION. CLIP ANGLE AT EACH STUD FINISH CEILING. REFER TO REFLECTED CEILING PLAN. A2- 3 1/8" WALL A3- 4 1/4" WALL A6- 6 5/8" WALL Fx- "X" =METAL FURRING SIZE F1- 7/8" FURRING CHANNEL F2- 1 1/2" "Z" FURRING CHANNEL F3- 1 -1/2" FURRING CHANNEL 16 GAUGE HORIZONTAL STEEL STRAPS AT 32" O.C. VERTICALLY. ANCHOR TO EACH STUD. 1 1 / 2 " 1/ 2 " CONTINUOUS 20 GA. SHEET METAL FILLER FASTENED TO DECK WITH WIDTH TO SPAN 3 RIBS MIN. COPE GYPSUM BOARD AROUND METAL DECK PROFILE. 1/ 2 " 1" VARIES VARIES 5/8" 1" 5/8" GYPSUM BOARD ON EACH SIDE OF STUDS B2- 3 3/4" WALL B3- 4 7/8" WALL B6- 7 1/4" WALL VARIES VARIES VARIES VARIES 5/8" 5/8" 6" M I N . VARIES 5/8" D1- 2 3/8" WALL D2- 3 1/4" WALL D3- 4 3/8" WALL D4- 4 3/4" WALL D5- 6 3/4" WALL 5/8" F1- 1 1/2" WALL F2- 2 1/8" WALL F3- 2 1/8" WALL GROMMET - EXACT LOCATIONS TO BE COORDINATED WITH OWNER 3 5/8" METAL STUDS AT 16" O.C. 4"H BASE 3/4" PARTICLE BOARD WITH PLASTIC LAMINATE FINISH 5/8" GYPSUM DRYWALL VARIES - REFER TO PLAN 4" H BASE 1 1 / 2 " RAKKS SUPPORT BRACKET; 3'-0" O.C. MAX. COUNTERTOP TO BE SOLID SURFACE OR PLASTIC LAMINATE WITH EASED EDGES - REFER TO ELEVATIONS 2' - 6 " 3 3/4" GROMMET - EXACT LOCATIONS TO BE COORDINATED WITH OWNER 3 5/8" METAL STUDS AT 16" O.C. TACKABLE SURFACE (TF1T) 3/4" SOLID SURFACE OVER 3/4" PARTICLE BOARD SUBSTRATE 3/4" PARTICLE BOARD WITH PLASTIC LAMINATE FINISH EASED EDGE EA. SIDE 1 1 / 2 " 5/8" GYPSUM DRYWALL FIRE-RETARDANT WOOD BLOCKING 10" VARIES - REFER TO PLAN COUNTERTOP TO BE SOLID SURFACE WITH EASED EDGES - REFER TO ELEVATIONS 4"H BASE 4" H BASE 1 1 / 2 " 1' - 0 " RAKKS SUPPORT BRACKET; 3'-0" O.C. MAX. HARDWOOD TRIM TO MATCH PL11T, FRAMING TILE ON FOUR SIDES. MT4 OVER TILE BACKER BOARD 3' - 0 " 1' - 6" (CURVED WALL) VARIES - SEE PLAN 2' - 0" 3 5/8" METAL STUDS AT 16" O.C. 3/4" SOLID SURFACE OVER 3/4" PARTICLE BOARD SUBSTRATE WITH EASED EDGES 3/4" PARTICLE BOARD WITH PLASTIC LAMINATE FINISH 4" H BASE BASE CABINET WITH PLASTIC LAMINATE FINISH COOKTOP BY OWNER 2' - 6 " 6" 4" H. BASE RAKKS ELIPSE SUPPORT BRACKET 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 A010.5 WALL TYPES, GENERAL NOTES AND DETAILS 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 MARK DATE DESCRIPTION 1 1/2" = 1'-0" ARCH- WALL TYPES - BP5 TOILET ACCESSORIES - BP5 1 SURFACE MOUNTED PAPER TOWEL DISPENSER 2 SURFACE MOUNTED SOAP DISPENSER EQUIPMENT SCHEDULE- BP5 NUMBER NAME REMARKS 200 COPIER - FLOOR O.F.O.I. 201 COMPUTER MONITOR O.F.O.I. 202 SINGLE DOOR REFRIGERATOR O.F.O.I. 203 HIGH DENSITY STORAGE O.F.O.I. 204 CASH REGISTER O.F.O.I. 205 DISHWASHER - GE PROFILE O.F.O.I. 206 OVEN - GE PROFILE O.F.O.I. 207 COOKTOP - GE PROFILE O.F.O.I. 208 MICROWAVE - GE PROFILE O.F.O.I. 209 REFRIGERATOR - GE PROFILE O.F.O.I. 210 CEILING MOUNTED PROJECTOR O.F.O.I. 211 CEILING MOUNTED SCREEN-LARGE O.F.O.I. 212 EXHAUST HOOD O.F.O.I. 1" = 1'-0" 1 CASEWORK SECTION 1 - LOW COUNTER - BP5 1" = 1'-0" 2 CASEWORK SECTION 2 - HIGH COUNTER - BP5 1" = 1'-0" 3 CASEWORK SECTION 3 - COMMUNITY ROOM