HomeMy WebLinkAboutBP5 CDs.pdfCODE SUMMARY PROJECT INFORMATION: NAME: ST. VINCENT CARMEL HOSPITAL 13500 N. MERIDIAN STREET CARMEL, IN 46032 PROJECT DESCRIPTION: NEW WOMEN'S CENTER AND CONNECTOR TO EXISTING HOSPITAL OWNER ADDRESS: DUKE REALTY 100, 600 E. 96TH STREET INDIANAPOLIS, IN 46240 CONTACT: KURT MEYER 317-808-6000 ARCHITECT: BSA LIFESTRUCTURES 9365 COUNSELORS ROW INDIANAPOLIS, IN 46240 317-819-7878 APPLICABLE CODES: 2008 INDIANA BUILDING CODE (IBC) 2008 INDIANA FIRE CODE (IFC) 2000 LIFE SAFETY CODE NFPA 101 2009 INDIANA ELECTRICAL CODE (IEC) 2008 INDIANA MECHANICAL CODE (IMC) 2012 INDIANA PLUMBING CODE (IPC) 2010 INDIANA ENERGY CONSERVATION CODE (IECC) MEDICAL OFFICE BUILDING FLOOR/AREA AREA (GROSS) OCCUPANCY CLASSIFICATION FIRST FLOOR WOMEN'S CENTER 27,107 SQ. FT. B SECOND FLOOR WOMEN'S CENTER 21,079 SQ. FT. B THIRD FLOOR WOMEN'S CENTER 21,028 SQ. FT. B FOURTH FLOOR WOMEN'S CENTER 20,399 SQ. FT. B FIRST FLOOR HOSPITAL CONNECTOR 1,894 SQ. FT. I-2 SECOND FLOOR HOSPITAL CONNECTOR 1,917 SQ. FT. R-1 THIRD FLOOR HOSPITAL CONNECTOR 1,973 SQ. FT. I-2 CONSTRUCTION TYPE: ALLOWABLE AREA: ALLOWABLE HEIGHT: BUILDING DATA: TYPE IIB (NON-COMBUSTIBLE, NON RATED) CONSTRUCTION TABULAR AREA 23,000 SQ. FT. FRONTAGE INCREASE +12,880 SQ. FT. SPRINKLER INCREASE +46,000 SQ. FT. ALLOWABLE PER FLOOR 81,880 SQ. FT. 5 STORIES; 75 FT. LIFE SAFETY FEATURES: SPRINKLER SYSTEM THROUGHOUT STANDPIPE SYSTEM FIRE RATED SEPARATION WALLS FIREPROOFING AT APPLICABLE STEEL FRAMING AND FLOOR SLABS SMOKE DETECTORS & FIRE ALARM SYSTEM FIRE EXTINGUISHERS SPACED ACCORDINGLY EMERGENCY LIGHTS - BATTERY BACK-UP EXIT LIGHTS - BATTERY BACK-UP BUILDING HEIGHT: 4 STORIES; 67.5 FT. HOSPITAL CONNECTOR CONSTRUCTION TYPE: TYPE IA BUILDING HEIGHT: 3 STORIES VARIANCE RECEIVED #12-12-36: TABLE 705.4 A 2 HOUR FIRE BARRIER WILL BE USED IN LIEU OF THE REQUIRED 2 HOUR PARTY WALL TO SEPARATE THE NEW MEDICAL OFFICE BUILDING (WOMEN'S CENTER) FROM THE EXISTING MEDICAL OFFICE BUILDINGS POB 1, 2, 3. A PARTY WALL IS NOT PERMITTED TO HAVE OPENINGS. PATIENTS AND STAFF MUST MOVE BACK AND FORTH FROM THE HOSPITAL AND OTHER MEDICAL OFFICE BUILDINGS THROUGH THE PARTY WALL INTO THE NEW WOMEN'S CENTER. 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com TM WOMEN'S CENTER 13420 N. MERIDIAN ST., CARMEL, IN 46032 ST. VINCENT CARMEL HOSPITAL WOMEN'S CENTER BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 04610082 BID PACKAGE 5 - TENANT IMPROVEMENTS DRAWING INDEX- BP5 10 - ELECTRICAL BP5 E210.5 FIRST FLOOR LIGHTING PLAN E310.5 FIRST FLOOR POWER PLAN E320.5 SECOND FLOOR POWER PLAN E410.5 FIRST FLOOR SYSTEMS PLAN E500.5 ENLARGED ELECTRICAL ROOMS E600.5 ELECTRICAL SCHEDULES E800.5 ELECTRICAL DETAILS DRAWING INDEX- BP5 08 - MECHANICAL BP5 H210.5 FIRST FLOOR HVAC PLAN H220.5 SECOND FLOOR HVAC PLAN HPE1.5 HVAC SCHEDULES, DETAILS AND SCHEMATICS DRAWING INDEX- BP5 05 - PLUMBING BP5 P310.5 FIRST FLOOR PLUMBING PLAN - BP5 P400.5 FOUNDATION SANITARY PLAN - BP5 DRAWING INDEX- BP5 03- INTERIORS - BP5 IF010.5 FINISH SPECIFICATIONS AND NOTES IF111.5 FIRST FLOOR FINISH PLAN DRAWING INDEX- BP5 03- ARCHITECTURE - BP5 A010.5 WALL TYPES, GENERAL NOTES AND DETAILS A111.5 FIRST FLOOR DIMENSION PLAN A112.5 FIRST FLOOR ARCHITECTURAL PLAN A113.5 FIRST FLOOR REFLECTED CEILING PLAN A500.5 OPENING SCHEDULE AND DETAILS A610.5 FIRST FLOOR INTERIOR ELEVATIONS DRAWING INDEX- BP5 00- GENERAL - BP5 A000.5 COVER SHEET/CODE SUMMARY XX DIMENSION PLAN SYMBOLS NEW COLUMN LINE DETAIL INDICATOR AREA OF DETAIL DETAIL NUMBER SHEET NUMBER ROOM NAME DESIGNATION ROOM NUMBER DESIGNATION PLAN NOTE DESIGNATION DOOR NUMBER DESIGNATION FLOOR DRAIN CURTAIN TRACK W/ CURTAIN F.D. A101 1 SIM SIMILAR ROOM 000 10 1 1 XX EXISTING COLUMN LINE H. O . AU T O NEW DOOR NEW WALL DOOR WITH MAGNETIC HOLD OPEN DEVICES DOOR WITH AUTOMATIC DOOR OPERATOR NEW DOOR NEW WALL PUSH PLATE FOR AUTO DOOR OPERATOR CARD READER FOR ELECTRIC DOOR LATCH KEYPAD FOR ELECTRIC DOOR LATCH PROXIMITY SENSOR TOUCHLESS ACTUATOR CR PP TA PS KP 2-HOUR RATED FIRE BARRIER- 2H WALL RATINGS GENERAL DIM. PLAN NOTES 3-HOUR RATED FIRE BARRIER- 3H 1-HOUR RATED FIRE BARRIER- 1H C. ALL INTERIOR GYPSUM DRYWALL WALLS SHALL BE TYPE 'B3' UNLESS NOTED OTHERWISE. D. E. ALL DIMENSIONS ARE TO CENTER OF COLUMN LINES, FACE OF DRYWALL OR TO FACE OF EXISTING WALL FINISH, UNLESS NOTED OTHERWISE. REFER TO 'IF' SHEET SERIES FOR ADDITIONAL INTERIOR FINISH INFORMATION. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL FOR ADDITIONAL INFORMATION. F. G. ALL INTERIOR GYPSUM DRYWALL COLUMN SURROUNDS SHALL BE WALL TYPE 'A2' UNLESS NOTED OTHERWISE. H. CONTRACTOR SHALL VERIFY ALL EXISTING CONSTRUCTION AND NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. A. B. REFER TO SHEET A500.5 FOR OPENING SCHEDULE AND TYPICAL INTERIOR DOOR OPENING DETAILS. REFER TO SHEET A010.5 FOR WALL TYPES. PROVIDE 5/8" GYPSUM DRYWALL ON INSIDE OF ALL TENANT SPACE WALLS. GYPSUM DRYWALL TO BE FOIL FACED AT ALL EXTERIOR WALL LOCATIONS. I. ALL COLUMN SURROUNDS SHALL BE 1'-0" FROM CENTERLINE OF COLUMN TO EXTERIOR FACE OF DRYWALL IN ALL DIRECTIONS, UNLESS NOTED OTHERWISE. J. WALL TYPE WALL TYPE SUFFIX XX.# DOOR FRAMES SHALL BE TYPICALLY 6" FROM PERPENDICULAR CORNER TO DOOR OPENING (INSIDE OF FRAME), ULESS NOTED OTHERWISE. K. 1 A000 2 3 4 XX ARCH. PLAN SYMBOLS NEW COLUMN LINE DETAIL INDICATOR AREA OF DETAIL DETAIL NUMBER SHEET NUMBER ROOM NAME DESIGNATION ROOM NUMBER DESIGNATION PLAN NOTE DESIGNATION EQUIPMENT DESIGNATION. REFER TO EQUIPMENT SCHEDULE. ELEVATION TAG CURTAIN TRACK W/ CURTAIN GENERAL ARCH. PLAN NOTES A. B. A101 1 SIM SIMILAR 000 ROOM 000 1 REFER TO SHEET A010.5 FOR TOILET ACCESSORIES SCHEDULE. PAINTING CONTRACTOR SHALL LABEL, ABOVE CEILING, ALL FIRE RATED WALL CONSTRUCTION AND SMOKE BARRIER WALL CONSTRUCTION IN ACCORDANCE WITH SPECIFICATION. C. REFER TO SHEET A010.5 FOR EQUIPMENT SCHEDULE. REFER TO M/E/P DRAWINGS TO COORDINATE CONNECTIONS. XX EXISTING COLUMN LINE D. ALL FURNITURE SHOWN FOR REFERENCE ONLY. E. REFER TO INTERIOR FINISH PLANS FOR LOCATIONS OF HANDRAILS, BUMPRAILS, CORNER GUARDS, AND WALL PROTECTION. TOILET ACCESSORY NOTE DESIGNATION 1 F. REFER TO INTERIOR FINISH PLANS FOR WINDOW SHADE TYPES AND LOCATIONS. G. PROVIDE (2) COAT HOOKS CENTERED ON BACK SIDE OF DOOR IN EACH FITTING ROOM. ALL COAT HOOKS TO BE MOUNTED AT 5'-6" A.F.F. GENERAL RC PLAN NOTES A. ALL LAY-IN ACOUSTICAL CEILINGS SHALL BE INSTALLED AT 9'-0" ABOVE FINISH FLOOR, UNLESS NOTED OTHERWISE. B. REF. CEILING PLAN SYMBOLS ACT - 1 SUSPENDED LAY-IN CEILING SYSTEM RECESSED "CAN" TYPE LIGHT FIXTURE OR PENDANT CEILING MOUNTED EXIT LIGHT CUBICLE CURTAIN TRACK AND CURTAIN 2'x4' LIGHTING FIXTURE 2'x2' LIGHTING FIXTURE RETURN AIR GRILLE SUPPLY AIR GRILLE SUPPLY AIR GRILLE CEILING HEIGHT ABOVE FINISH FLOOR DRYWALL BULKHEAD/CEILING 1'x4' LIGHTING FIXTURE ACOUSTICAL CEILING TILE - TYPE EXHAUST AIR GRILLE +9'-0" LOBBY LIGHT FIXTURE (EXISTING) CHAIN HUNG LIGHT FIXTURE ALL LAY-IN ACOUSTICAL CEILINGS SHALL BE TYPE 3, UNLESS NOTED OTHERWISE. C. ALL GYPSUM DRYWALL BULKHEADS SHALL BE INSTALLED AT 8'-6" ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. ALL GYPSUM DRYWALL BULKHEADS ABOVE CASEWORK SHALL BE INSTALLED AT 7'-2" ABOVE FINISHED FLOOR. D. REFER TO INTERIOR FINISH PLANS FOR GYPSUM DRYWALL BULKHEAD FINISHES. E. FIRE RATINGS NOT SHOWN ON REFLECTED CEILING PLANS. REFER TO LIFE SAFETY PLANS OR DIMENSION PLANS FOR WALL RATING LOCATIONS. F. CAN LIGHTS WITHIN GYPSUM DRYWALL BULKHEADS SHALL BE INSTALLED AT CENTERLINE OF BULKHEAD WIDTH. INT. ELEV. SYMBOL LEGEND GENERAL INT. ELEV. NOTES A. REFER TO SHEET A010.5 FOR THE EQUIPMENT LIST AND TOILET ACCESSORIES SCHEDULE. REFER TO M/E/P DRAWINGS TO COORDINATE CONNECTIONS C. ALL DIMENSIONS ARE TAKEN TO THE FACE OF FINISHED MATERIAL. D. COORDINATE BULKHEAD HEIGHTS INDICATED ON INTERIOR ELEVATIONS WITH THAT SHOWN ON THE REFLECTED CEILING PLAN. CONFIRM ANY DISCREPANCIES WITH THE ARCHITECT PRIOR TO CONSTRUCTION. E. PROVIDE A 4" HIGH INTEGRAL BACK SPLASH ON ALL COUNTERS WITH RECESSED SINKS. INSTALL SIDE SPLASHES WHERE THESE COUNTERS ABUT A WALL, UNLESS NOTED OTHERWISE. F. PROVIDE ADJUSTABLE SHELVING WITHIN ALL WALL AND BASE CABINETRY AS SHOWN BY DASHED LINE. G. PROVIDE 12" CLEAR INTERIOR DIMENSION ON ALL UPPER WALL CABINETS UNLESS NOTED OTHERWISE. H. COORDINATE ALL WALL OUTLETS TO AVOID CONFLICT WITH CASEWORK. I. INSTALL WOOD BLOCKING TO STUDS TO SUPPORT ALL WALL-MOUNTED CABINETRY AND EQUIPMENT AS REQUIRED. J. ALL CASEWORK SHALL BE FINISHED WOOD UNLESS NOTED OTHERWISE. K. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTING CABINETRY. L. PROVIDE FILLER PANELS AT ALL LOCATIONS WHERE CABINETRY ABUTS A WALL. ALL BASE CABINETS SHALL BE 2'-0" DEEP UNLESS NOTED OTHERWISE. XX NEW COLUMN LINE SECTION INDICATOR DETAIL INDICATOR AREA OF DETAIL DETAIL NUMBER SHEET NUMBER ELEVATION NOTE DESIGNATION A101 1 SIM SIMILAR 1 A101 SIM 1 TOILET ACCESSORY # B. ABBREVIATION LIST A.F.F. ABOVE FINISHED FLOOR ALT. ALTERNATE ALUM. ALUMINUM APP. APPLICABLE ARCH. ARCHITECTURAL AXON. AXONOMETRIC DRAWING B.C. BRICK COURSE / BRICK COURSES B.O. BOTTOM OF CL. CENTERLINE CLR. CLEAR C.M.U. CONCRETE MASONRY UNIT CONFIG. CONFIGURATION CONT. CONTINUOUS / CONTINUED C.F.C.I. CONTRACTOR FURNISHED, CONTRACTOR INSTALLED C.J. CONTROL JOINT DIMS. DIMENSIONS E.J. EXPANSION JOINT AT BRICK VENEER ELEC. ELECTRICAL ELEV. ELEVATION EQ. EQUAL E.W.C. ELECTRIC WATER COOLER EXT. EXTERIOR F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET F.R.T. FIRE RETARDANT TREATED GA. GAUGE GALV. GALVANIZED G.S.F. GROSS SQUARE FEET GYP. GYPSUM HORIZ. HORIZONTAL / HORIZONTALLY INT. INTERIOR L.C.C. LEAD COATED COPPER JT. JOINT MAX. MAXIMUM MECH. MECHANICAL / MECHANICALLY MER. MOLDED EPOXY RESIN MFGR. MANUFACTURER/S MIN. MINIMUM M.O. MASONRY OPENING O.C. ON CENTER O.H. OPPOSITE HAND O.F.O.I. OWNER FURNISHED, OWNER INSTALLED O.F.C.I. OWNER FURNISHED, CONTRACTOR INSTALLED P. PLASTIC RAD./R/ RADIUS REF. REFER / REFERENCE R.O. ROUGH OPENING SIM. SIMILIAR S.F. SQUARE FEET S.S. STAINLESS STEEL S.S.G. STRUCTURAL SILICON GLAZED STRUC. STRUCTURAL T.O. TOP OF U.N.O. UNLESS NOTED OTHERWISE V. VARIES VERT. VERTICAL / VERTICALLY V.I.F. VERIFY IN FIELD W/ WITH DIAMETER GENERAL WALL TYPE NOTES A. DIMENSIONS IN PLAN AND ELEVATION ARE TAKEN TO THE FACE OF FINISH DRYWALL OR CENTER LINE OF COLUMN, UNLESS NOTED OTHERWISE. B. ALL INTERIOR WALLS SHALL BE TYPE 'B3' UNLESS NOTED OTHERWISE. ALL COLUMN SURROUNDS SHALL BE WALL TYPE 'A2' UNLESS NOTED OTHERWISE. C. PROVIDE FULL HEIGHT STRUCTURAL STUDS TO THE STRUCTURE ABOVE AT ALL CORNERS, AT DOOR AND BORROWED LIGHT FRAMES, JAMBS, AND BEHIND ALL WALL MOUNTED EQUIPMENT AND/ OR CASEWORK. D. FURNISH AND INSTALL FIRE STOP SEALANT WHERE GYPSUM WALL BOARD MEETS FIREPROOFING ON COLUMNS, BEAMS, AND METAL DECK AT FIRE RATED PARTITIONS. E. ALL PENETRATIONS THROUGH FIRE AND SMOKE RATED WALLS SHALL BE FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS. F. AT FIRE RATED WALLS, PROVIDE TESTED FIRE STOPPING SYSTEM AT HEAD OF WALL. AT ALL NON-FIRE RATED WALLS, INCLUDING SOUND RESISITANT WALLS, SMOKE PARTITIONS AND CORRIDOR WALLS, PACK VOID SPACE BETWEEN METAL DECK FLUTES AND TOP OF PARTITION WITH FIRE SAFING AND SEAL GAP AT DRYWALL WITH ACOUSTICAL SEALANT. G. ALL WALLS SHALL BE TREATED AS SOUND RESISTANT WALLS (UNLESS NOTED OTHERWISE). SEAL AROUND ALL PENETRATIONS AND INSTALL SOUND ATTENTION BATTS FULL HEIGHT. FIT INSULATION TIGHT AROUND DUCT AND PIPE PENETRATIONS. ALL SOUND RESISTANT WALLS WITH SOUND ATTENUATION BATTS SHALL HAVE ACOUSTICAL SEALANT UNDER BOTTOM RUNNER TRACK. H. ALL STUDS SHALL BE AT 16" O.C. UNLESS NOTED OTHERWISE. 1. INDICATES ENTIRE WALL CONSTRUCTION TO STOP 6" ABOVE FINISHED CEILING. 2. INDICATES GYPSUM BOARD ON ONE SIDE TO STOP 6" ABOVE FINISHED CEILING. 3. INDICATES PARTIAL HEIGHT WALL. a. INDICATES NO SOUND ATTENUATION BLANKETS b. INDICATES ADDITIONAL LAYER OF 5/8" GYPSUM BOARD OVER WALL. c. INDICATES FOIL-FACED GYPSUM BOARD. WALL TYPE SYMBOL X1.1x INDICATES CONSTRUCTION TYPE NUMERICAL INDICATION OF STUD/MASONRY SIZE SUFFIX INDICATES MODIFICATIONS TO WALL CONSTRUCTION HEIGHT SUFFIX INDICATES HORIZONTAL MODIFICATIONS WALL TYPES SUFFIX Ax WALL PARTITION 1 1/2" = 1'-0" BASE SECTION PLAN SECTION HEAD SECTION Bx WALL PARTITION 1 1/2" = 1'-0" BASE SECTION PLAN SECTION HEAD SECTION Fx WALL PARTITION 1 1/2" = 1'-0" BASE SECTION PLAN SECTION HEAD SECTION 01 TYP. METAL STUD PARTITION HEAD DETAIL 1 1/2" = 1'-0" NON-BEARING PARALLEL TO RIBS OF DECK PERPENDICULAR TO RIBS OF DECK Dx WALL PARTITION 1 1/2" = 1'-0" BASE SECTION PLAN SECTION HEAD SECTION AX-'X'=METAL STUD SIZE A2-2 1/2" METAL STUDS A3-3 5/8" METAL STUDS A6-6" METAL STUDS BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE STEEL STUD RUNNER TRACK. STUDS SCREWED AT BOTTOM FLOOR SLAB 5/8" GYPSUM WALL BOARD METAL STUDS (REFER TO CHART BELOW) DEFLECTION TRACK BOTTOM OF STRUCTURE FASTEN GYPSUM BOARD TO STUDS NOT TO THE TOP TRACK BX-'X'=METAL STUD SIZE B2-2 1/2" METAL STUDS B3-3 5/8" METAL STUDS B6-6" METAL STUDS BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE (FIRESTOP AT RATED PARTITIONS) FLOOR SLAB STEEL STUD RUNNER TRACK. STUDS SCREWED ON EA. SIDE AT BOTTOM BOTTOM OF STRUCTURE 1/2" SEALANT SPACE (FIRESTOP SYSTEM AT RATED PARTITIONS) DEFLECTION TRACK FASTEN GYPSUM BOARD TO STUDS NOT TO THE TOP TRACK METAL STUDS (REFER TO CHART BELOW) 1/2" SEALANT SPACE BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 5/8" GYPSUM WALL BOARD 1/2" SEALANT SPACE FLOOR SLAB 5/8" GYPSUM BOARD FURRING CHANNEL (REFER TO CHART BELOW) ADJACENT WALL CONSTRUCTION BOTTOM OF STRUCTURE FINISH CEILING. REFER TO REFLECTED CEILING PLAN. NON-RATED NON-RATED 1 HOUR RATED PARTITION; UL #V450 (WHERE NOTED ON PLAN) SOUND ATTENUATION BATTS SOUND ATTENUATION BATTS METAL DECK. REFER TO STRUCTURAL DRAWINGS. METAL EDGE TRIM WHERE EXPOSED TO VIEW. FASTEN STEEL RUNNER TO METAL DECK. FRICTION FIT METAL STUDS TO DEFLECTION TRACK AND FASTEN GYPSUM BOARD TO STUDS. DO NOT FASTEN TO DEFLECTION TRACK. MAINTAIN GAP BETWEEN STEEL DEFLECTION TRACK AND METAL STUD/GYPSUM BOARD TO ACCOMMODATE STRUCTURAL DEFLECTION. COMPRESSED SAFING INSULATION. (FIRESTOPPING AT RATED PARTITIONS) STEEL RUNNER WITH MIN. 2" FLANGES CONTINUOUS ACOUSTIC SEALANT BOTH SIDES. (FIRESTOPPING AT RATED PARTITIONS) REFER TO PARTITION TYPES FOR WALL CONSTRUCTION. D1- 1 5/8" STUD D2- 2 1/2" STUD D3- 3 5/8" STUD D4- 4" STUD D5- 6" STUD BASE: REFER TO FINISH DRAWINGS FLOOR: REFER TO FINISH DRAWINGS 1/2" SEALANT SPACE FLOOR SLAB 5/8" GYPSUM BOARD METAL STUDS (REFER TO CHART BELOW) BOTTOM OF STRUCTURE NON-RATED WALL 1/8" ALIGNMENT SPACE (IF APPLICABLE) ADJACENT WALL CONSTRUCTION. CLIP ANGLE AT EACH STUD FINISH CEILING. REFER TO REFLECTED CEILING PLAN. A2- 3 1/8" WALL A3- 4 1/4" WALL A6- 6 5/8" WALL Fx- "X" =METAL FURRING SIZE F1- 7/8" FURRING CHANNEL F2- 1 1/2" "Z" FURRING CHANNEL F3- 1 -1/2" FURRING CHANNEL 16 GAUGE HORIZONTAL STEEL STRAPS AT 32" O.C. VERTICALLY. ANCHOR TO EACH STUD. 1 1 / 2 " 1/ 2 " CONTINUOUS 20 GA. SHEET METAL FILLER FASTENED TO DECK WITH WIDTH TO SPAN 3 RIBS MIN. COPE GYPSUM BOARD AROUND METAL DECK PROFILE. 1/ 2 " 1" VARIES VARIES 5/8" 1" 5/8" GYPSUM BOARD ON EACH SIDE OF STUDS B2- 3 3/4" WALL B3- 4 7/8" WALL B6- 7 1/4" WALL VARIES VARIES VARIES VARIES 5/8" 5/8" 6" M I N . VARIES 5/8" D1- 2 3/8" WALL D2- 3 1/4" WALL D3- 4 3/8" WALL D4- 4 3/4" WALL D5- 6 3/4" WALL 5/8" F1- 1 1/2" WALL F2- 2 1/8" WALL F3- 2 1/8" WALL GROMMET - EXACT LOCATIONS TO BE COORDINATED WITH OWNER 3 5/8" METAL STUDS AT 16" O.C. 4"H BASE 3/4" PARTICLE BOARD WITH PLASTIC LAMINATE FINISH 5/8" GYPSUM DRYWALL VARIES - REFER TO PLAN 4" H BASE 1 1 / 2 " RAKKS SUPPORT BRACKET; 3'-0" O.C. MAX. COUNTERTOP TO BE SOLID SURFACE OR PLASTIC LAMINATE WITH EASED EDGES - REFER TO ELEVATIONS 2' - 6 " 3 3/4" GROMMET - EXACT LOCATIONS TO BE COORDINATED WITH OWNER 3 5/8" METAL STUDS AT 16" O.C. TACKABLE SURFACE (TF1T) 3/4" SOLID SURFACE OVER 3/4" PARTICLE BOARD SUBSTRATE 3/4" PARTICLE BOARD WITH PLASTIC LAMINATE FINISH EASED EDGE EA. SIDE 1 1 / 2 " 5/8" GYPSUM DRYWALL FIRE-RETARDANT WOOD BLOCKING 10" VARIES - REFER TO PLAN COUNTERTOP TO BE SOLID SURFACE WITH EASED EDGES - REFER TO ELEVATIONS 4"H BASE 4" H BASE 1 1 / 2 " 1' - 0 " RAKKS SUPPORT BRACKET; 3'-0" O.C. MAX. HARDWOOD TRIM TO MATCH PL11T, FRAMING TILE ON FOUR SIDES. MT4 OVER TILE BACKER BOARD 3' - 0 " 1' - 6" (CURVED WALL) VARIES - SEE PLAN 2' - 0" 3 5/8" METAL STUDS AT 16" O.C. 3/4" SOLID SURFACE OVER 3/4" PARTICLE BOARD SUBSTRATE WITH EASED EDGES 3/4" PARTICLE BOARD WITH PLASTIC LAMINATE FINISH 4" H BASE BASE CABINET WITH PLASTIC LAMINATE FINISH COOKTOP BY OWNER 2' - 6 " 6" 4" H. BASE RAKKS ELIPSE SUPPORT BRACKET 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 A010.5 WALL TYPES, GENERAL NOTES AND DETAILS 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 MARK DATE DESCRIPTION 1 1/2" = 1'-0" ARCH- WALL TYPES - BP5 TOILET ACCESSORIES - BP5 1 SURFACE MOUNTED PAPER TOWEL DISPENSER 2 SURFACE MOUNTED SOAP DISPENSER EQUIPMENT SCHEDULE- BP5 NUMBER NAME REMARKS 200 COPIER - FLOOR O.F.O.I. 201 COMPUTER MONITOR O.F.O.I. 202 SINGLE DOOR REFRIGERATOR O.F.O.I. 203 HIGH DENSITY STORAGE O.F.O.I. 204 CASH REGISTER O.F.O.I. 205 DISHWASHER - GE PROFILE O.F.O.I. 206 OVEN - GE PROFILE O.F.O.I. 207 COOKTOP - GE PROFILE O.F.O.I. 208 MICROWAVE - GE PROFILE O.F.O.I. 209 REFRIGERATOR - GE PROFILE O.F.O.I. 210 CEILING MOUNTED PROJECTOR O.F.O.I. 211 CEILING MOUNTED SCREEN-LARGE O.F.O.I. 212 EXHAUST HOOD O.F.O.I. 1" = 1'-0" 1 CASEWORK SECTION 1 - LOW COUNTER - BP5 1" = 1'-0" 2 CASEWORK SECTION 2 - HIGH COUNTER - BP5 1" = 1'-0" 3 CASEWORK SECTION 3 - COMMUNITY ROOM 10. 1. 5. 6. 7.. 9. 11. 12.. 13. 14. 15.. E 10 B A 7 8 932 E15 A'' 2. 3. 8. 16. 17. 18. .4 20. 19. 1.2 5.2 5.8 10.1 4 C D 1 9.5 1 WAITING 1200 CONSULTATION 1201 OFFICE 1202 6' - 0 " 12' - 4 7/8" BOUTIQUE 1500 CASHIER 1503 BUS. OFFICE 1504 STORAGE 1506 FITTING 1505 FITTING 1507 STORAGE 1508 DISPLAY AREA 1501 STORAGE 1502 FUTURE CAFE 1400 SHELL SPACE 1600 COMMUNITY/ CONFERENCE ROOM 1700 SHELL SPACE 1800 1' - 0" 3' - 4 7 / 8 " 5' - 6" 5' - 6" 4' - 6 7 / 8 " 4' - 1 1 / 8 " 8' - 8 " 12 0 1 12 0 2 1502 1504 1505-1 15 0 5 - 2 1506 15 0 7 - 2 1507-1 1508 15 0 1 17 0 0 - 1 17 0 0 - 2 1 1 1 13'-10 1/8" 4'-8 1/2" 1'-0" 1'-0" 9'-2 1/2" 9'-2 1/2" 1' - 0 " 6' - 4 7 / 8 " 16 ' - 6 " 6' - 0 " 11'-0" 2' - 2" 2' - 2" 9" 9' - 3" 9' - 3" 3 222 4 CR 10 ' - 2 " B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 B3-1 A610.5 1 B3-1 5 5 EXISTING VESTIBULE 1000 B3.1 B3.1 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN 1/8" = 1'-0" 04610082 A111.5 FIRST FLOOR DIMENSION PLAN 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 MARK DATE DESCRIPTION 1/8" = 1'-0" 1 FIRST FLOOR DIMENSION PLAN - BP5 NOTES- DIMENSION PLAN - BP5 * NOT ALL PLAN NOTES APPEAR ON EACH SHEET. ** REFER TO SHEET A010.5 FOR GENERAL NOTES, WALL TYPES, EQUIPMENT SCHEDULE, TOILET ACCESSORY SCHEDULE, AND TYPICAL DETAILS. 1 ALIGN WALL WITH ADJACENT WALL. 2 3 5/8" METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM DRYWALL EACH SIDE TO 7'-0" A.F.F. ANCHOR TO FLOOR. COORDINATE EXACT LOCATION/LENGTH WITH DISPLAY MANUFACTURER. 3 INFILL WALL TO MATCH EXISTING AT NEW DOOR LOCATION. 4 RECESSED FIRE EXTINGUISHER CABINET. 5 EXISTING RECESSED FIRE EXTINGUISHER CABINET. .. 10. 1. 5. 6. 7.. 9. 11. 12.. 13. 14. 15.. E 10 B A 7 8 932 E15 A'' 2. 3. 8. 16. 17. 18. .4 20. 19. 1.2 5.2 5.8 10.1 4 C D 1 9.5 STORAGE 1506 FITTING 1505 FITTING 1507 STORAGE 1508 BUS. OFFICE 1504 CASHIER 1503 DISPLAY AREA 1501 STORAGE 1502 BOUTIQUE 1500 A610.5 8 A610.5 10 9 SHELL SPACE 1800 SHELL SPACE 1600 COMMUNITY/ CONFERENCE ROOM 1700 1 CONSULTATION 1201 OFFICE 1202 WAITING 1200 A610.5 8 FUTURE CAFE 1400 A610.5 11 203 201 210 211 1 1 1 1 1 2 22 2 2 2 2 3 A610.5 1 EXISTING VESTIBULE 1000 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN 1/8" = 1'-0" 04610082 A112.5 FIRST FLOOR ARCHITECTURAL PLAN 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 1/8" = 1'-0" 1 FIRST FLOOR ARCHITECTURAL PLAN - BP5 MARK DATE DESCRIPTION NOTES- ARCHITECTURAL PLAN - BP5 * NOT ALL PLAN NOTES APPEAR ON EACH SHEET ** REFER TO SHEET A010.5 FOR GENERAL NOTES, WALL TYPES, EQUIPMENT SCHEDULE, TOILET ACCESSORY SCHEDULE, AND TYPICAL DETAILS. 1 PLASTIC LAMINATE SLATWALL BY OTHERS. 2 DISPLAY CASEWORK BY OTHERS. 3 PODIUM AT EXISTING VESTIBULE 1000. REFER TO INTERIOR ELEVATIONS 18 & 19/A610.5 1 +9' - 0" 2" 2' - 8 " 6' - 2 1/2" 2' - 6 " 2' - 6" 2' - 6" 2' - 6 " 2' - 7 1 / 8 " +8' - 6" 1501 1502 1503 1504 1505 1506 1507 1508 1200 1201 1202 1700 1800 1600 1400 1 11 1 1 1 1 1 1 1 1 22 +9' - 0" +10' - 0" +8' - 6" +8' - 6" 2' - 2" 2' - 2" 210 211 212 3 3 3 2'-8" 1500 1 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN 1/8" = 1'-0" 04610082 A113.5 FIRST FLOOR REFLECTED CEILING PLAN 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 1/8" = 1'-0" 1 FIRST FLOOR CEILING PLAN - BP5 MARK DATE DESCRIPTION NOTES- REFLECTED CEILING PLAN - BP5 * NOT ALL NOTES APPEAR ON EACH SHEET. ** REFER TO A010.5 FOR GENERAL NOTES, WALL TYPES, EQUIPMENT SCHEDULE, TOILET ACCESSORY SCHEDULE, AND TYPICAL DETAILS. 1 EXISTING CEILING TO REMAIN. 2 BID PACKAGE 3 TO EXTEND EXISTING CEILING INTO NEW DOOR ALCOVE. COORDINATE SIZE AND LOCATIONS WITH BID PACKAGE 3 CONTRACTOR. 3 CAN LIGHTS WITHIN GYPSUM DRYWALL BULKHEADS SHALL BE INSTALLED AT CENTERLINE OF BULKHEAD WIDTH. REMARKS R1 R2 R3 KEYPAD TRILOGY AUTO OPERATOR 1. REFER TO ELECTRICAL WIRING DIAGRAMS OF POWERED OPENINGS FOR ADDITIONAL INFORMATION. HM HOLLOW METAL WD SOLID CORE WOOD AL ALUMINUM GL GLASS G1 G2 SAFETY GLASS SOLID ETCH GLASS GENERAL NOTES MATERIAL ABBREVIATIONS GLASS TYPES OPENING SCHEDULE LEGEND UN L E S S N O T E D OT H E R W I S E 01 FLUSH A1.1 SEE SCHEDULE VARIES 2" SEE SCHEDULE VARIES 2" VA R I E S S E E S C H E D U L E 2" NOTE: HEAD DETAIL SIMILAR TO JAMB. DOOR JAMB ANCHOR HOLLOW METAL FRAME GROUT SOLID AT FIRE RATED DOORS, TYP. BATT INSULATION 5/8" GYPSUM BOARD 01 JAMB 02 JAMB 02 HEAD ALUMINUM FRAMING SYSTEM SAFETY GLASS DOOR REFER TO WALL TYPES FOR STUD DIMENSION DOUBLE STRUCTURAL STUDS TO STRUCTURE ABOVE REFER TO WALL TYPES FOR STUD DIMENSION EDGE OF DOOR FRAME (BELOW) SAFETY GLASS DOOR 1/ 4 " BATT INSULATION REFER TO WALL TYPES FOR STUD DIMENSION 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 A500.5 OPENING SCHEDULE AND DETAILS 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 MARK DATE DESCRIPTION DOOR SCHEDULE - FIRST FLOOR - BP5 OPENING #ROOM NAME RATING (MINS.) OPENING FRAME GLASS TYPE HW SET REMARKS SIZE MATERIAL ELEV. MATERIAL ELEV. DETAIL SET HEIGHT WIDTH 1201 CONSULTATION 7' - 0" 3' - 0" WD A1.1 HM 01 01 18 1202 OFFICE 7' - 0" 3' - 0" WD A1.1 HM 01 01 22 1501 DISPLAY AREA 7' - 0" 3' - 0" WD A1.1 HM 01 01 25 1502 STORAGE 7' - 0" 2' - 4" WD A1.1 HM 01 01 38 1504 BUS. OFFICE 7' - 0" 3' - 0" WD A1.1 HM 01 01 50 1505-1 FITTING 7' - 0" 4' - 0" WD A1.1 HM 01 01 49 1505-2 FITTING 45 7' - 0" 3' - 0" WD A1.1 HM 01 01 51 1506 STORAGE 45 7' - 0" 3' - 0" WD A1.1 HM 01 01 01 1507-1 FITTING 7' - 0" 4' - 0" WD A1.1 HM 01 01 49 1507-2 FITTING 45 7' - 0" 3' - 0" WD A1.1 HM 01 01 51 1508 STORAGE 7' - 0" 3' - 0" WD A1.1 HM 01 01 52 1700-1 COMMUNITY/ CONFERENCE ROOM 7' - 0" 3' - 0" WD A1.1 HM 01 01 53 1700-2 COMMUNITY/ CONFERENCE ROOM 7' - 0" 3' - 0" WD A1.1 HM 01 01 53 1/4" = 1'-0" ARCH- DOOR AND FRAME ELEVATIONS-BP5 1 1/2" = 1'-0" ARCH - TYP. OPENING DETAILS - BP5 2' - 6 " 3' - 6 " 1 3 204 204 18 MT1 PL11T SS2T SS1T 1 A010.5 2 A010.5 3'-0" 3'-10" 6'-0" 3' - 6 " 1' - 2 " 2' - 6 " 1 3 204 MT1 PL11T SS2T 2 A010.5 10'-6" 3' - 0 " 6" 1' - 2 " 2' - 6 " 1 7 310 204 SS2T SS1T PL11T 18 3'-0" FILLER 3'-0" FILLER 1'-6" 3'-0" FILLER 2' - 6 " 4' - 8 " 1 19 9 7 13 310 2 204 200 19 SS1T 18 8' - 0" FILLER 3' - 0" 2' - 9" FILLER 2' - 2 " 2' - 6 " 1 11 10 7 6 FILLER 3' - 3" 3' - 3" FILLER 2' - 6 " 2' - 2 " 2' - 6 " 7' - 11 1/4" 1 11 10 7 1 7 3 10 6204 201 18 SS1T SS2T PL11T SS1T 3'-10" 6'-0" 3' - 0 " 4" 2' - 8 " 1' - 0" 2' - 10" 1' - 0" FILLER 1 23 24 22 2' - 0" 24 34 2' - 1 0 " 2" 2' - 2 " 2' - 0 " FILLER 1' - 9" 2' - 0" FILLER FILLER 2' - 9" 2' - 0" FILLER 1 17 12 16 14 1 25 1' - 3" 3' - 3" FILLER 3' - 0 " 1' - 8 " 2' - 6 " 4' - 0" FILLER 3' - 2" 1 7 12 16 201 5 2' - 6 " 6" 1 8 207 PL11T 20 212 33 3' - 0 " 2' - 6 " 1 8 PL11T 20 212 3' - 0 " FILLER 2' - 3" 3' - 3" 3' - 3" 2' - 4" 2' - 0" 2' - 0" FILLER 1 20 26 25 15 206 208 207 PL11T PL11T 21 OPEN 212 FILLER 4' - 6" 2' - 0" 2' - 0" FILLER 3' - 0 " 2' - 2 " 2' - 0 " FILLER 2' - 3" 2' - 3" 2' - 0" 2' - 0" FILLER 1 1 4 21 9 205 2 OPEN 25 19 FILLER 2' - 0" 2' - 0" FILLER 1 9 27 209 2' - 6 " 6" 4' - 2 " OPEN 28 5. A 3 .4 A610.5 14 17 16 A610.5 13 A610.5 12 1' - 6 " 2' - 7 " 4' - 0 " 2 4 ' - 0 " 3' - 7 1/2" 16' - 3" 3' - 7 1/2" 207 205 209 3 A010.5 A610.5 15 29 29 30 4' - 2 " 4" 3' - 1 0 " 2'-6" 31 PL11T 4" 3' - 1 0 " 31 2'-0" PL11T 1 8 PL11T 20 3' - 0 " 2' - 6 " 212 4 D A610.5 2 A610.5 6 5 7 4 A610.5 3 BUS. OFFICE 1504 CASHIER 1503 204 204 202 200 201 8'-4" 3'-0" 3'-10" 6'-0" 29 6' - 0 " 4' - 6 " 6' - 0" 1 1/4" 5" 3 3/4" 10" 2'-1" 32 2' - 1 " 7' - 7 3 / 8 " 1' - 0 " 1'-0" 1'-7" 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN 1/4" = 1'-0" 04610082 A610.5 FIRST FLOOR INTERIOR ELEVATIONS 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 1/4" = 1'-0" 2 BOUTIQUE DISPLAY / CASHIER 1/4" = 1'-0" 3 CASHIER 1/4" = 1'-0" 4 CASHIER 2 1/4" = 1'-0" 5 BUS. OFFICE / CASHIER 1 1/4" = 1'-0" 6 BUS. OFFICE / CASHIER 2 1/4" = 1'-0" 7 BUS. OFFICE / CASHIER 3 1/4" = 1'-0" 8 TYPICAL FITTING 1/4" = 1'-0" 10 STORAGE 2 1/4" = 1'-0" 9 STORAGE 1 MARK DATE DESCRIPTION 1/4" = 1'-0" 12 COMMUNITY ROOM 1 1/4" = 1'-0" 13 COMMUNITY ROOM 2 1/4" = 1'-0" 14 COMMUNITY ROOM 3 1/4" = 1'-0" 16 COMMUNITY ROOM 5 1/4" = 1'-0" 17 COMMUNITY ROOM 6 NOTES - INTERIOR ELEVATION - BP5 * NOT ALL PLAN NOTES APPEAR ON EACH SHEET. ** REFER TO SHEET A010.5 FOR GENERAL NOTES, WALL TYPES, EQUIPMENT SCHEDULE, TOILET ACCESSORY SCHEDULE, AND TYPICAL DETAILS. 1 4" H. BASE. REFER TO INTERIOR FINISH PLANS FOR ADDITIONAL INFORMATION. 2 FINISHED END PANEL. 3 1 1/2" THICK SOLID SURFACE TRANSACTION TOP WITH DOUBLE EASED EDGES. 4 1 1/2" THICK SOLID SURFACE COUNTERTOP WITH DOUBLE EASED EDGE WITH 4" H. BACK AND SIDE SPLASHES. PROVIDE FULL HEIGHT WALL PROTECTION (WP1T) AT ALL WET LOCATIONS. 5 1 1/2" THICK PLASTIC LAMINATE COUNTERTOP WITH POST FORMED EDGE, PROVIDE 4" H. BACK AND SIDE SPLASHES WHERE SHOWN. PROVIDE 2 1/2" GROMMETS. VERIFY LOCATIONS WITH TENANT. 6 1 1/2" THICK PLASTIC LAMINATE COUNTERTOP WITH POST FORMED EDGE, PROVIDE 2 1/2" GROMMETS. VERIFY LOCATIONS WITH TENANT. 7 METAL SUPPORT BRACKETS, PAINT TO MATCH ADJACENT WALL. 8 1 1/2" THICK x 18" D. SOLID SURFACE COUNTERTOP WITH DOUBLE EASED EDGES. 9 GYPSUM DRYWALL BULKHEAD. 10 TACKABLE WALLCOVERING (TW1T). REFER TO SHEET IF010.5 FOR FINISH SPECIFICATIONS. 11 12" D. (INSIDE CLEAR) PRE-MANUFACTURED WOOD WALL CABINETS. REFER TO SHEET IF010.5 FOR FINISH INFORMATION. 12 24" D. PRE-MANUFACTURED WOOD BASE CABINET WITH CONFIGURATION OF DOORS AND DRAWERS AS SHOWN. REFER TO IF010.5 OR FINISH INFORMATION. 13 24" D. x 86" H. CUSTOM CABINET WITH FULL HEIGHT DOORS AND ADJUSTABLE SHELVING SHOWN DASHED WITH PLASTIC LAMINATE ON ALL EXPOSED SURFACES. 14 24" D. PRE-MANUFACTURED WOOD SINK BASE CABINET. DRAWERS TO BE FIXED FRONTS. DOORS TO HAVE NO PULLS. PROVIDE LOCKS ON DOORS FOR MAINTENANCE ACCESS. 15 24" D. CUSTOM PLASTIC LAMINATE MICROWAVE CABINET WITH CONFIGURATION OF DRAWERS AS SHOWN. 16 12" D. (INSIDE CLEAR) PRE-MANUFACTURED WOOD WALL CABINET WITH OPEN ADJUSTABLE SHELF. REFER TO IF010.5 FOR FINISH INFORMATION. 17 1 1/2" THICK SOLID SURFACE COUNTERTOP WITH DOUBLE EASED EDGE WITH 6" H. BACK AND SIDE SPLASHES. PROVIDE FULL HEIGHT WALL PROTECTION (WP1T) AT ALL WET LOCATIONS. 18 1 1/2" THICK SOLID SURFACE COUNTERTOP WITH DOUBLE EASED EDGE, PROVIDE 2 1/2" GROMMETS. VERIFY LOCATIONS WITH TENANT. 19 12" D. (INSIDE CLEAR) CUSTOM PLASTIC LAMINATE WALL CABINETS. REFER TO SHEET IF010.5 FOR FINISH INFORMATION. 20 1 1/2" THICK SOLID SURFACE COUNTERTOP WITH DOUBLE EASED EDGE. 21 24" D. CUSTOM PLASTIC LAMINATE BASE CABINET WITH OPEN FRONT AND SINGLE DOOR TO FLOOR FOR TRASH. REFER TO IF010.5 OR FINISH INFORMATION. 22 DECORATIVE MIRROR, WITH ANGLED MOUNTING, TO BE FURNISHED BY ARTWORK VENDOR. 23 1 1/2" THICK x 15" D. PLASTIC LAMINATE COUNTERTOP WITH POST FORMED EDGE. 24 14" D. PRE-MANUFACTURED WOOD BASE CABINET WITH CONFIGURATION OF DOORS AND DRAWERS AS SHOWN. REFER TO IF010.5 OR FINISH INFORMATION. 25 24" D. CUSTOM PLASTIC LAMIANTE SINK BASE CABINET. DRAWERS TO BE FIXED FRONTS. DOORS TO HAVE NO PULLS. PROVIDE LOCKS ON DOORS FOR MAINTENANCE ACCESS. 26 24" D. CUSTOM PLASTIC LAMINATE BASE CABINET WITH CONFIGURATION OF DOORS AND DRAWERS AS SHOWN. REFER TO IF010.5 OR FINISH INFORMATION. 27 24" D. x 86" H. CUSTOM CABINET WITH FULL HEIGHT SINGLE DOOR AND ADJUSTABLE SHELVING SHOWN DASHED WITH PLASTIC LAMINATE ON ALL EXPOSED SURFACES. 28 24" D. x 86" H. CUSTOM CABINET WITH TRASH BASE CABINET AS SHOWN (OPEN FRONT AND SINGLE DOOR TO FLOOR). TOP PORTION TO BE SINGLE DOOR AND ADJUSTABLE SHELVING SHOWN DASHED WITH PLASTIC LAMINATE ON ALL EXPOSED SURFACES. 29 LINE OF WALL BELOW COUNTERTOP. REFER TO SECTIONS FOR ADDITIONAL INFORMATION. 30 LINE OF EXHAUST HOOD ABOVE. 31 PLASTIC LAMINATE VALET PODIUM WITH CONFIGURATION OF DRAWERS AND DOORS AS SHOWN. PROVIDE LOCKS ON ALL DOORS/DRAWERS AND HEAVY DUTY LOCKABLE CASTERS. 32 DISPLAY CASEWORK BY OTHERS. 33 RAKKS SUPPORT BRACKET AT 3'-0" O.C. MAXIMUM: ELIPSE EC-0812 WITH STAINLESS STEEL FINISH. 34 WALL MOUNTED LIGHT FIXTURE. 1/4" = 1'-0" 11 ENLARGED COMMUNITY/CONFERENCE PLAN 1/4" = 1'-0" 18 PODIUM FRONT 1/4" = 1'-0" 19 PODIUM SIDE 1/4" = 1'-0" 15 COMMUNITY ROOM 4 1/4" = 1'-0" 1 ENLARGED BOUTIQUE PLAN ARROWS INDICATE DIRECTION OF PATTERN 2' - 0 " 2' - 0" 2' - 0" ARROWS INDICATE DIRECTION OF PATTERN 2' - 0 " ARROWS INDICATE DIRECTION OF PATTERN 2' - 0" 2' - 0 " - PROVIDE TROWELABLE UNDERLAYMENT AS REQUIRED TO ALLOW FOR FLUSH AND LEVEL TRANSITION. - USE THIS DETAIL FOR TRANSITIONS BETWEEN DISSIMILAR PRODUCTS/MANUFACTURERS. METAL DIVIDER STRIP CONCRETE SLAB - LEVEL AS REQUIRED VCT/SV/LVP VCT/SV/LVP CPT/WM METAL DIVIDER STRIP VCT/SV/LVP PROVIDE TROWELABLE UNDERLAYMENT AS REQUIRED TO ALLOW FOR FLUSH AND LEVEL TRANSITION. CONCRETE SLAB - LEVEL AS REQUIRED BACKING PROVIDE TROWELABLE UNDERLAYMENT AS REQUIRED TO ALLOW FOR FLUSH AND LEVEL TRANSITION. METAL DIVIDER STRIP CRACK ISOLATION MEMBRANE PORCELAIN TILE VCT/SV/LVP CONCRETE SLAB - LEVEL AS REQUIRED GENERAL FINISH NOTES A. PATTERN NAME, COLOR AND NUMBER FOR EACH MATERIAL ARE GIVEN WHENEVER POSSIBLE ON THE FINISH PLAN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING ANY DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT/DESIGNER SO THAT THE CORRECT MATERIAL IS INSTALLED. B. PAINT ALL BULKHEADS, SOFFITS, AND DRYWALL CEILING SURFACES (P1T) UNLESS NOTED OTHERWISE. ALL BULKHEADS, SOFFITS, AND DRYWALL CEILING SURFACES SHOULD BE FINISHED WITH THE SAME MATERIAL AND OR COLOR ON ALL FACES AS SPECIFIED, UNLESS NOTED OTHERWISE. REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL CEILING FINISHES. C. ALL FLOORING MATERIAL TRANSITIONS SHALL BE CENTERED UNDER THE DOOR IN THE CLOSED POSITION. D. REFER TO THIS SHEET FOR TYPICAL FLOOR TRANSITION AND FLOOR PATTERN INSTALLATION DETAILS. E. REFER TO OPENING SCHEDULE AND PROJECT MANUAL FOR DOOR STAIN INFORMATION. F. THERE SHALL NOT BE PAINT CONDITIONS THAT OCCUR CAUSING FINISH OR COLOR TO TERMINATE ON AN OUTSIDE CORNER UNLESS SPECIFICALLY NOTED OTHERWISE. IF THIS CONDITION OCCURS BRING IT TO THE ATTENTION OF THE DESIGNER IMMEDIATELY. G. REFER TO PROJECT MANUAL SECTION “CAST-IN-PLACE CONCRETE” FOR SPECIFICATIONS FOR SEALED CONCRETE (SC). H. ALL FLOORING TO BE INSTALLED PERPENDICULAR TO ROOM WALLS UNLESS NOTED OTHERWISE. I. DASHED IN FURNITURE TO BE OWNER FINISHED, OWNER INSTALLED. J. PAINT ALL INTERIOR HOLLOW METAL DOOR AND WINDOW FRAMES (P3T) UNLESS NOTED OTHERWISE. REFER TO SPECIFICATIONS FOR PAINT TYPE AND FINISH. K. PAINT ALL INTERIOR HOLLOW METAL DOORS (P2T). REFER TO SPECIFICATIONS FOR PAINT TYPE AND FINISH. L. PATCH AND MATCH EXISTING FINISHES AS NEEDED FOR NEW CONSTRUCTION AND DEMOLITION. M. PAINT ALL GRILLES, VENTS, ELECTRICAL PANELS, ACCESS PANELS, ETC. TO MATCH ADJACENT WALL UNLESS NOTED OTHERWISE. N. PROVIDE JOHNSONITE LEVEL SYSTEM OR EQUAL AS NEEDED FOR SMOOTH TRANSITION BETWEEN FLOORING MATERIALS. SLOPE TO BE 1 TO 20. O. PAINT STEEL COLUMNS, BEAMS, STRUCTURE ETC. EXPOSED TO VIEW IN FINISHED AREAS (P2T) UNLESS NOTED OTHERWISE. P. FINISH BEHIND FIXED EQUIPMENT SUCH AS CABINETRY, CASEWORK, CHALK AND TACK/MARKERBOARDS, LOCKERS ETC. Q. ALL SOLID SURFACE SINKS TO BE (SSK1T). R. ALL TACKABLE WALLCOVERINGS TO BE (TW1T). S. ALL PRE-MANUFACTURERED WOOD CABINETRY TO BE (PMC1T). T. ALL VERTICAL PLASTIC LAMINATE SURFACES TO BE (PL11T) UNLESS NOTED OTHERWISE. ALL HORIZONTAL PLASTIC LAMINATE WORK SURFACES AND BACKSPLASH TO BE (PL1T) UNLESS NOTED OTHERWISE. U. ALL SOLID SURFACE WORK SURFACES TO BE (SS1T) UNLESS NOTED OTHERWISE. V. REFER TO INTERIOR ELEVATIONS FOR WALL PROTECTION NEAR SINKS WITHIN CASEWORK. W. REFER TO SHEET A010.5 FOR TYPICAL WALL PROTECTION ELEVATION AT TOILET ROOMS. 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 IF010.5 FINISH SPECIFICATIONS AND NOTES 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 MARK DATE DESCRIPTION FINISH SPECIFICATIONS - TENANT IMPROVEMENTS NAME: MANUFACTURER: STYLE: NUMBER: COLOR: SIZE: CONTACT: COMMENTS: CARPET CPT1T SHAW DIFFUSE 59575 75150 ANNUAL 24" x 24" JASON HAYES, jason.hayes@shawinc.com, 317.965.2929 INSTALLATION TO BE QUARTER-TURNED, UNLESS NOTED OTHERWISE. REFER TO DETAIL 3, THIS SHEET, FOR DETAIL. CPT2T SHAW CATALYST TILE 59579 64330 SEASON 24" x 24" JASON HAYES, jason.hayes@shawinc.com, 317.965.2929 INSTALLATION TO BE VERTICAL ASHLAR, UNLESS NOTED OTHERWISE. REFER TO DETAIL 2, THIS SHEET, FOR DETAIL. CPT3T SHAW CATALYST TILE 59579 64855 MOSAIC 24" x 24" JASON HAYES, jason.hayes@shawinc.com, 317.965.2929 INSTALLATION TO BE VERTICAL ASHLAR, UNLESS NOTED OTHERWISE. REFER TO DETAIL 2, THIS SHEET, FOR DETAIL. CPT4T SHAW EMBARK TILE 5T040 37761 SHADOW 24" x 24" JASON HAYES, jason.hayes@shawinc.com, 317.965.2929 INSTALLATION TO BE VERTICAL ASHLAR, UNLESS NOTED OTHERWISE. REFER TO DETAIL 2, THIS SHEET, FOR DETAIL. CPT5T TANDUS ATMOSPHERE 03666 49508 EARTHENWARE 24" x 24" DOUG EDWARDS, dedwards@tandus.com, 317.443.9579 INSTALLATION TO BE BRICK ASHLAR, UNLESS NOTED OTHERWISE. REFER TO DETAIL 1, THIS SHEET, FOR DETAIL. CORNER GUARD CG1T C/S ACROVYN REFER TO PROJECT MANUAL (TAPE-ON) 997 IRISH CREAM CHERI LONGERBONE, Cheri@wmbakerco.com, 317-402-3467 CG3 C/S ACROVYN REFER TO PROJECT MANUAL 172 SAND DUNE CHERI LONGERBONE, Cheri@wmbakerco.com, 317-402-3467 CUBICLE CURTAIN CC1T ARCHITEX RX 6008 SANUR KELLI DETTY, kellidetty@architex-ljh.com, 317.752.2324 DECORATIVE GLASS DG1T SKYLINE BOTANICA, SHEER 4C SHEER 4C DALE GINGER, dale.g@skydesign.com, 773.208.6400 SIDE 1: ECO-ETCH PATTERN ON CLEAR FIELD, SIDE 2: TEXTURED PATTERN DG2T SKYLINE CLASSICS SOLID ETCH, 50% SHADE DALE GINGER, dale.g@skydesign.com, 773.208.6400 SIDE 1: CLEAR; SIDE 2: ECO-ETCH SHADE WITH RUB-IN SEALER FABRIC F1T ARCHITEX MARQUISETTE N/A GATE KELLI DETTY, kellidetty@architex-ljh.com, 317.752.2324 LUXURY VINYL PLANK LVP1T FLEXCO NATURAL ELEMENTS 615 WALNUT 4" x 36" TOM HEWETT, tom@gilford.com, 502.693.1183 LVP2T FLEXCO NATURAL ELEMENTS 625 NATURAL BEECH 4" x 36"TOM HEWETT, tom@gilford.com, 502.693.1183 LVP3T FLEXCO NATURAL ELEMENTS 616 RUSTIC WALNUT 4" x 36"TOM HEWETT, tom@gilford.com, 502.693.1183 MOSAIC TILE MT1 ARTISTIC TILE ESTRELLA SILVER BLEND 12.5" x 12.25" INTERLOC KING SHEET MARY ANN LUCAS, ARCHITECTURAL BRICK & TILE, maryannl@archbricktile.com, 317-842-2888 TO BE USED WITH GR1, NO SUBSTITUTIONS PAINT / EPOXY PAINT P1T / EP1T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A0057 CRISP LINEN P2T / EP2T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1822 DESERT CASTLE P3T / EP3T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1825 PALM SPRINGS TAN P4T / EP4T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1777 NEUTRAL WHEAT P5T / EP5T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1713 SMOKEY GLASS P6T / EP6T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1708 AUTHENTIC BROWN P7T / EP7T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A0196 PLUM JAM P8T / EP8T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1846 TUMBLEWEED TRAIL P9T / EP9T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A0943 LICHEN GREEN P10T / EP10T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1901 SHENANDOAH VALLEY P11T / EP11T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A0825 WILD HONEY P12T / EP12T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1818 BASKETRY P13T / EP13T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A0734 GOLDEN NEEDLES P14T / EP14T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A1894 MONSOON P15T / EP15T GLIDDEN PROFESSIONAL REFER TO PROJECT MANUAL A0608 TIMBERLINE PLASTIC LAMINATE PL1T WILSONART 4912-38 GILDED MESH LUKE BASKETT, LUMBERMEN'S, lukeb@lumbermens-inc.com, 317.417.1582 PL2T WILSONART 4872-60 WESTERN STORM LUKE BASKETT, LUMBERMEN'S, lukeb@lumbermens-inc.com, 317.417.1582 PL3T ARBORITE P-259 CA TATAMI CHOKORETO JERRY ROECK, jroeck.tamarack@fuse.net, 513.407.1185 GRAIN DIRECTION TO RUN HORIZONTALLY PL4T NOT USED PL5T WILSONART 4848-38 MISSION SAGE LUKE BASKETT, LUMBERMEN'S, lukeb@lumbermens-inc.com, 317.417.1582 PL6T ARBORITE P-299 SR TATAMI SERORI JERRY ROECK, jroeck.tamarack@fuse.net, 513.407.1185 GRAIN DIRECTION TO RUN HORIZONTALLY PL7T NOT USED PL8T WILSONART 4794-60 WINDSWEPT BRONZE LUKE BASKETT, LUMBERMEN'S, lukeb@lumbermens-inc.com, 317.417.1582 PL9T ARBORITE P-309 CA SAGE ANGORA JERRY ROECK, jroeck.tamarack@fuse.net, 513.407.1185 PL10T NOT USED PL11T WILSONART 7936k-07 WILLIAMSBURG CHERRY LUKE BASKETT, LUMBERMEN'S, lukeb@lumbermens-inc.com, 317.417.1582 GRAIN DIRECTION TO RUN VERTICALLY PRE-MANUFACTURED WOOD CABINETRY PMC1T ARISTROKRAFT SINCLAIR (BIRCH) CAFE RESILIENT BASE RB1T JOHNSONITE COVE 280 SHORELINE 4" HIGH BARB LUSTIG, E.J. WELCH, blustig@ejwelch.com, 317.443.8137 RB2T JOHNSONITE COVE 280 SHORELINE 6" HIGH BARB LUSTIG, E.J. WELCH, blustig@ejwelch.com, 317.443.8137 SHEET VINYL SV1T ALTRO SUPREMA SU2046 OATMEAL JASON QUEAR, GAIL FORCE ENTERPRISES, jasonquear@gmail.com, 317-363-8988 REFER TO SPEC SECTIONS 09 05 60 AND 09 65 00 FOR MOISTURE VAPOR REDUCING MEMBRANE INFORMATION. SOLID SURFACE SS1T CORIAN N/A CANVAS HEIDI GESSNER, heidi.gessner@ovsco.com, 317.590.0290 SS2T CORIAN N/A PEBBLE HEIDI GESSNER, heidi.gessner@ovsco.com, 317.590.0290 SS3T CORIAN N/A MEDEA HEIDI GESSNER, heidi.gessner@ovsco.com, 317.590.0290 SS4T CORIAN N/A SUEDE HEIDI GESSNER, heidi.gessner@ovsco.com, 317.590.0290 SOLID SURFACE SINK SSK1T CORIAN N/A GLACIER WHITE HEIDI GESSNER, heidi.gessner@ovsco.com, 317.590.0290 TACKABLE FABRIC TF1T KNOLL TEXTILES MATCHPOINT W1145/2 FOSSIL NANCY WRIGHT, nwright@knoll.com, 317.408.4269 TACKABLE WALLCOVERING TW1T WALLTALKERS TAC-WALL C250-82 QUARRY DARLA CULP, dculp@koroseal.com, 317-443-8985 VINYL COMPOSITION TILE VCT1T MANNINGTON ESSENTIALS 133 ALMONDINE 12" x 12" DAWN MCDONALD, dawn_mcdonald@mannington.com, 317.260.7997 VCT2T JOHNSONITE AZROCK VCT V-276 BERRY RED 12" x 12" BARB LUSTIG, E.J. WELCH, blustig@ejwelch.com, 317.443.8137 VCT3T MANNINGTON ESSENTIALS 209 DARK CHOCOLATE 12" x 12"DAWN MCDONALD, dawn_mcdonald@mannington.com, 317.260.7997 VCT4T MANNINGTON ESSENTIALS 189 BED ROCK 12" x 12" DAWN MCDONALD, dawn_mcdonald@mannington.com, 317.260.7997 VCT5T MANNINGTON ESSENTIALS 105 SPROUT 12" x 12" DAWN MCDONALD, dawn_mcdonald@mannington.com, 317.260.7997 VCT6T MANNINGTON ESSENTIALS 135 SEASPRAY 12" x 12" DAWN MCDONALD, dawn_mcdonald@mannington.com, 317.260.7997 VCT7T MANNINGTON ESSENTIALS 125 SILVER PINE 12" x 12" DAWN MCDONALD, dawn_mcdonald@mannington.com, 317.260.7997 VCT8T MANNINGTON ESSENTIALS 123 WHEAT 12" x 12" DAWN MCDONALD, dawn_mcdonald@mannington.com, 317.260.7997 VCT9T MANNINGTON ESSENTIALS 246 BRONZE 12" x 12" DAWN MCDONALD, dawn_mcdonald@mannington.com, 317.260.7997 WALL PROTECTION WP1T C/S ACROVYN REFER TO PROJECT MANUAL 997 IRISH CREAM CHERI LONGERBONE, Cheri@wmbakerco.com, 317-402-3467 NOTE: THE SCHEDULE BELOW INCLUDES FINISHES FOR ALL TENANT SPACES. NOT ALL OF THE FINISHES BELOW WILL BE USED IN THIS BID PACKAGE. 1/2" = 1'-0" 1 CARPET TILE PATTERN - BRICK ASHLAR (BP5) 1/2" = 1'-0" 2 CARPET TILE PATTERN - VERTICAL ASHLAR (BP5) 1/2" = 1'-0" 3 CARPET TILE PATTERN - QUARTER TURN (BP5) 6" = 1'-0" 4 FLOORING TRANSITION - RESILIENT FLOORING TO RESILIENT FLOORING (BP5) 6" = 1'-0" 5 FLOORING TRANSITION - RESILIENT FLOORING TO CARPET (BP5) 6" = 1'-0" 6 FLOORING TRANSITION - RESILIENT FLOORING TO PORCELAIN TILE (BP5) .. 10. 1. 5. 6. 7.. 9. 11. 12.. 13. 14. 15.. E 10 B A 7 8 932 E15 A'' 2. 3. 8. 16. 17. 18. .4 20. 19. 1.2 5.2 5.8 10.1 4 C D 1 9.5 STORAGE 1506 VCT1T RB1T P2T FITTING 1505 CPT4T RB1T P2T 2 FITTING 1507 CPT4T RB1T P2T 2 STORAGE 1508 VCT1T RB1T P2T BUS. OFFICE 1504 CPT4T RB1T P2T CASHIER 1503 LVP3T RB1T P2T DISPLAY AREA 1501 LVP3T RB1T P2T STORAGE 1502 LVP3T RB1T P2T BOUTIQUE 1500 LVP3T RB1T P2T SHELL SPACE 1800 -- -- -- SHELL SPACE 1600 -- -- -- COMMUNITY/ CONFERENCE ROOM 1700 CPT4T RB1T P2T 1 2 CONSULTATION 1201 CPT4T RB1T P2T 2 OFFICE 1202 CPT4T RB1T P2T 2 WAITING 1200 CPT5T RB1T P2T 2 FUTURE CAFE 1400 -- -- -- 1 LVP1T CPT4T 3 1 5 5 5 74 4 4 1 1 1 1 1 1 1 CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T CG1T 4 13 ' - 6 " FINISH REMARKS FINISH LEGEND BLOCK FINISH ABBREVIATIONS ACT ACOUSTICAL CEILING TILE CPT CARPET CG CORNER GUARD CC CUBICLE CURTAIN DG DECORATIVE GLASS EP EPOXY PAINT ETR EXISTING TO REMAIN F FABRIC GB GYPSUM BOARD LVP LUXURY VINYL PLANK P PAINT ROOM NAME ROOM NUMBER REMARKS COLUMN FLOOR BASE WALL NOTE: FINISHES INDICATED IN FINISH LEGEND BLOCKS ARE GENERAL OVERALL FINISHES FOR ROOM UNLESS OTHERWISE NOTED BY NOTE, REMARK, DETAIL, AND/OR ELEVATION. PL PLASTIC LAMINATE PMC PRE-MANUFACTURED WOOD CABINETRY PME PATCH AND MATCH EXISTING RB RESILIENT BASE SC SEALED CONCRETE (SPEC 03300) SS SOLID SURFACE SSK SOLID SURFACE SINK SV SHEET VINYL VCT VINYL COMPOSITION TILE WP WALL PROTECTION 1. REFER TO FINISH PLANS FOR FLOOR PATTERN, TRANSITIONS AND/OR ACCENT LOCATIONS. 2. REFER TO FINISH PLANS FOR ACCENT WALL LOCATIONS. FINISH PLAN NOTES 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 IF111.5 FIRST FLOOR FINISH PLAN 0461 BP #5 CONSTRUCTION DOCUMENTS SEPT. 12, 2014 MARK DATE DESCRIPTION 1/8" = 1'-0" 1 FIRST FLOOR FINISH PLAN - BP5 1 ARROWS INDICATE DIRECTION OF FLOORING PATTERN. 3 WALL TO RECEIVE P3T. 4 WALL TO RECEIVE P4T. 5 WALL TO RECEIVE P5T. 7 WALL TO RECEIVE P7T. 14 10 . 1. 5. 6. 7. . 9. 11 . 12.. E B A B.67 3 2 E1 6 E1 7 E1 8 E1 4 E1 5 A'' 2. 3. 8. .4 4. 8 6. 2 A2 0. 5 1. 2 5. 2 5. 8 D. 6 D. 3 C. 9 C. 6 C. 4 4 CD 1 9. 6E B.67 3 2 A'' 5. 2 5. 8 AA2 B 9. 11 . 12.. 7. . 6. 5. .4 1. E1 5 E1 4 ST O R A G E 15 0 6 FI T T I N G 15 0 7 DI S P L A Y A R E A 15 0 1 FI T T I N G 15 0 5 BU S . O F F I C E 15 0 4 CA S H I E R 15 0 3 ST O R A G E 15 0 8 BO U T I Q U E 15 0 0 ST O R A G E 15 0 2 SH E L L S P A C E 16 0 0 CO M M U N I T Y / CO N F E R E N C E RO O M 17 0 0 SH E L L S P A C E 18 0 0 TB - 1 - 1 0 8 TB - 1 - 1 0 4 TB - 2 - 1 0 1 ECG2 T TB - 2 - 1 0 1 5 6 TB - 1 - 1 0 3 WA I T I N G 12 0 0 OFFICE 1202CONSULTATION12011 3 2 1 4 16 " X 1 0 " 16 " X 1 2 " 4 2 " X 1 2 " 42 " X 1 2 " 18 " X 1 2 " 1 8 " X 1 2 " 4 2 " X 1 2 " 42 " X 1 2 " 20 " X 1 2 " 12 " X 1 2 " 12 " X 1 0 " 2 0 " X 1 2 " 14 " X 1 2 " 8" X 8 " 10 " X 1 0 " 24 " X 1 4 " 42" X 12"42" X 12"ECG2ECG2 SD 1 - 8 0 SD1- 100 SD 1 - 1 8 0 SD 1 - 2 5 SD 1 - 7 0 SD 2 - 2 0 0 EC G 2 SD 1 - 5 0 SD 1 - 2 5 SD 2 - 2 7 5 SD 2 - 2 7 5 SD 1 - 5 0 SD 1 - 1 7 0 SD 1 - 1 6 5 SD 1 - 1 7 0 SD 1 - 1 7 0 SD 1 - 2 5 0 SD 1 - 2 5 0 EC G 1 TB - 1 - 1 1 4 14 " ø 12 " ø TB - 1 - 1 0 7 10 " X 1 2 " 10 " X 1 2 " 10 " ø 8" ø T TTB - 1 - 1 0 4 TB - 1 - 1 0 7 16 " X 1 6 " T TB - 1 - 1 1 4 EC G 1 GE N E R A L N O T E S A. NO P I P I N G O R D U C T W O R K S H A L L P A S S T H R O U G H E L E C T R I C A L R O O M S , EL E V A T O R E Q U I P M E N T R O O M S , S T A I R S H A F T S , E L E V A T O R S H A F T S O R SI M I L A R S P A C E S U N L E S S S Y S T E M S E R V E S S P A C E A N D I S L I K E W I S E S H O W N ON P L A N . B. WO M E N ' S C E N T E R F A L L S U N D E R S E C T I O N 9 . 4 . I O F T H E 2 0 0 1 A I A G U I D E L I N E S AS N O I N V A S I V E P R O C E D U R E S A R E T O B E P E R F O R M E D . C. CO N N E C T O R F A L L S U N D E R S E C T I O N 7 . 3 1 O F T H E 2 0 0 1 A I A G U I D E L I N E S A S A N EX T E N S I O N O F T H E E X I S T I N G H O S P I T A L . D. SE I S M I C R E S T R A I N T S H A L L N O T B E R E Q U I R E D F O R W O M E N ' S C E N T E R . E. SE I S M I C R E S T R A I N T S H A L L B E R E Q U I R E D F O R C O N N E C T O R . F. FA N P O W E R E D B O X A N D T E R M I N A L B O X D I S C H A R G E D U C T W O R K S H A L L B E TH E S A M E S I Z E A S U N I T D I S C H A R G E S I Z E U N L E S S N O T E D O T H E R W I S E . G. IN S T A L L R E T U R N G R I L L E S O U N D T R A P S S O T H E Y A R E N O T F A C I N G A N Y NE A R B Y F A N P O W E R E D T E R M I N A L B O X E S O R O T H E R S O U N D T R A P S . I F TH E R E A R E C O N F L I C T S I N A C O N G E S T E D A R E A , F A C I N G T H E S O U N D T R A P AW A Y F R O M F A N P O W E R E D T E R M I N A L B O X E S S H A L L B E T H E P R I O R I T Y . 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTORWOMEN'S CENTER KEYPLAN NPOB 1 SCALE DATE COORD DRAWN APPROVED FILE NAMECLIENT NO. :PROJECT NO.TM WOMEN'S CENTER CARMEL, IN As indicated04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvtKPMMCWMKCH210.5FIRST FLOOR HVAC PLAN 0461BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 PL A N N O T E S 1 4 2 " X 1 2 " S U P P L Y A I R D U C T U P . 2 4 2 " X 3 0 " R E T U R N A I R D U C T U P . 3 2 4 " X 1 2 " E X H A U S T A I R D U C T U P . 4 2 8 " X 1 2 " E X H A U S T A I R D U C T U P . 5 1 4 " X 1 4 " E X H A U S T D U C T U P T O K E F - 1 . I N S U L A T E D U C T I N 2 H O U R R A T E D F I R E W R A P CO M P L E T E U P T H R O U G H R O O F . 6 1 4 " X 1 4 " E X H A U S T D U C T D O W N T O K I T C H E N H O O D . I N S U L A T E D U C T I N 2 H O U R R A T E D FI R E W R A P C O M P L E T E W I T H I N R O O M . MARK DATE DESCRIPTION 14 C E X . D E X . 10 . 1. 5. 6. 7. . 9. 11 . 12 . . E B A B.67 3 2 E1 6 E1 7 E1 8 E1 4 E1 5 A'' 2. 3. 8. .4 4. 8 6. 2 A2 0. 5 1. 2 5. 2 5. 8 D. 6 D. 3 C. 9 C. 6 C. 4 4 CD 1 9. 6E B.67 3 2 A'' 5. 2 5. 8 AA2 B 9. 11 . 12 . . 7. . 6. 5. .4 1. E1 5 E1 4 KE F - 1 1 2 HP E 1 . 5 B GE N E R A L N O T E S A. NO P I P I N G O R D U C T W O R K S H A L L P A S S T H R O U G H E L E C T R I C A L R O O M S , EL E V A T O R E Q U I P M E N T R O O M S , S T A I R S H A F T S , E L E V A T O R S H A F T S O R SI M I L A R S P A C E S U N L E S S S Y S T E M S E R V E S S P A C E A N D I S L I K E W I S E S H O W N ON P L A N . B. WO M E N ' S C E N T E R F A L L S U N D E R S E C T I O N 9 . 4 . I O F T H E 2 0 0 1 A I A G U I D E L I N E S AS N O I N V A S I V E P R O C E D U R E S A R E T O B E P E R F O R M E D . C. CO N N E C T O R F A L L S U N D E R S E C T I O N 7 . 3 1 O F T H E 2 0 0 1 A I A G U I D E L I N E S A S A N EX T E N S I O N O F T H E E X I S T I N G H O S P I T A L . D. SE I S M I C R E S T R A I N T S H A L L N O T B E R E Q U I R E D F O R W O M E N ' S C E N T E R . E. SE I S M I C R E S T R A I N T S H A L L B E R E Q U I R E D F O R C O N N E C T O R . F. FA N P O W E R E D B O X A N D T E R M I N A L B O X D I S C H A R G E D U C T W O R K S H A L L B E TH E S A M E S I Z E A S U N I T D I S C H A R G E S I Z E U N L E S S N O T E D O T H E R W I S E . G. IN S T A L L R E T U R N G R I L L E S O U N D T R A P S S O T H E Y A R E N O T F A C I N G A N Y NE A R B Y F A N P O W E R E D T E R M I N A L B O X E S O R O T H E R S O U N D T R A P S . I F TH E R E A R E C O N F L I C T S I N A C O N G E S T E D A R E A , F A C I N G T H E S O U N D T R A P AW A Y F R O M F A N P O W E R E D T E R M I N A L B O X E S S H A L L B E T H E P R I O R I T Y . 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTORWOMEN'S CENTER KEYPLAN NPOB 1 SCALE DATE COORD DRAWN APPROVED FILE NAMECLIENT NO. :PROJECT NO.TM WOMEN'S CENTER CARMEL, IN As indicated04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvtKPMMKCMKCH220.5SECOND FLOOR HVAC PLAN 0461BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 1 / 8 " = 1 ' - 0 " 1 SE C O N D F L O O R H V A C P L A N B P 5 PL A N N O T E S 1 I N S T A L L 1 2 " R O U N D S T A I N L E S S S T E E L D I S C H A R G E D U C T A T A F I N A L M I N I M U M H E I G H T OF 7 2 " A B O V E R O O F . D U C T T O B E A N G L E D A T 4 5 D E G R E E S T O P O I N T A W A Y F R O M T H E WA L L S N E A R B Y . D I S C H A R G E D U C T T E R M I N A T I O N T O B E A M I N I M U M F I V E F E E T F R O M EA C H W A L L . 2 1 4 " X 1 4 " E X H A U S T D U C T D O W N . I N S T A L L 2 H O U R R A T E D F I R E W R A P O N A L L E X P O S E D DU C T B E T W E E N R O O F A N D F A N I N L E T . C O V E R F I R E W R A P W I T H A L U M I N U M J A C K E T PE R S P E C I F I C A T I O N 2 3 0 7 0 0 . MARK DATE DESCRIPTION S CS BI - X HO O D E KE F - 1 TE R M I N A L B O X TB - 1 - 1 1 4 11 7 5 / 3 5 0 FR O M R T U SE Q U E N C E O F O P E R A T I O N : 1. KE F - 1 I S A C T I V A T E D F R O M H O O D S W I T C H O R W H E N E V E R H O O D T E M P E R A T U R E I S 1 5 ° F ( A D J . ) A B O V E R O O M TE M P E R A T U R E . 2. WH E N K E F - 1 I S A C T I V A T E D T E R M I N A L B O X I N D E X E S T O 1 , 1 7 5 C F M C O N S T A N T V O L U M E T H R O U G H B M S . 3. WH E N K E F - 1 S W I T C H I S T U R N E D O F F , A 1 5 M I N U T E ( A D J . ) T I M E R I S S E T . W H E N T H E T I M E R R E A C H E S Z E R O , K E F - 1 I S DE A C T I V A T E D . 4. IF T H E H O O D F I R E S U P P R E S I O N S Y S T E M I S A C T I V A T E D T H E F O L L O W I N G S H A L L O C C U R : A. KE F - 1 S H A L L B E A C T I V A T E D . B. TE R M I N A L B O X I N D E X E S T O 1 , 1 7 5 C F M C O N S T A N T V O L U M E . C. TH E C O O K I N G E Q U I P M E N T S H A L L B E S H U T D O W N . 5. WH E N H O O D I S A C T I V A T E D W H I L E T H E A I R H A N D L I N G U N I T I S U N O C C U P I E D M O D E T H E A I R H A N D L I N G U N I T , R T U - 1 , SH A L L B E R E T U R N E D T O O C C U P I E D M O D E U N T I L T H E N E X T U N O C C U P I E D C Y C L E . NO T E : 1. CO N T R O L P O I N T S T O B E I N C O R P O R A T E D I N T O C L O S E S T D D C P A N E L . 2. TE R M I N A L B O X H E A T I N G C O N T R O L T O B E P E R T E R M I N A L B O X C O N T R O L S C H E M A T I C . P R O V I D E A L L TE R M I N A L U N I T C O N T R O L S P E R C O N T R O L S C H E M A T I C F O R V A V T E R M I N A L B O X ( D D C ) , W I T H C A V C O N T R O L W H E N IN D E X E D T O H O O D O P E R A T I O N M O D E . 3. HO O D M A N U F A C T U R E R T O P R O V I D E C O N T A C T S F O R C O N T R O L . 4. CO N T A C T S O N S U P P R E S S I O N S Y S T E M T O S T A R T F A N W H E N F I R E S U P P R E S S I O N S Y S T E M I S A C T I V A T E D . 5. BI - X S H A L L S E N D A L A R M T O L O C A L B U I L D I N G A L A R M P A N E L . 6. RO O M A N D E X H A U S T T E M P E R A T U R E S E N S O R S B Y K I T C H E N H O O D S U P P L I E R . T E M P E R A T U R E S E N S O R C O N T R O L S IN T E G R A L T H R O U G H H O O D C O N T R O L L E R . BY E C C LO C A T E S W I T C H ON H O O D BO - X E FI R E S U P P R E S S I O N S Y S T E M 4 T T E E BY E C C 6 6 HO A BY E . C . ST R DD C CO N T R O L L E R BO - Y E ELEV-A ELEVATION-A STRUCTURAL ROOFINSULATION (TYPICAL)FLASHING (TYPICAL)CANT STRIP (TYPICAL)EQUIPMENT RAILS VE R I F Y A C T U A L R O O F CO N S T R U C T I O N W I T H AR C H I T E C T U R A L D R A W I N G S 16 G A . Z I N C C O A T E D SH E E T M E T A L ( T Y P I C A L ) ROOFEQUIPMENT RAILSWEATHER PROOF HOUSING VERIFY ACTUAL ROOF CONSTRUCTION WITH ARCHITECTURAL DRAWINGS 2" WOOD DECK16" MIN.2-2"X10" MIN. SE E P L A N F O R D U C T C O N T I N U A T I O N HO L E T H R U R O O F 1 " L A R G E R (B O T H W A Y S ) T H A N D U C T S 2" X 1 4 " F R A M E & N A I L E R SE C U R E C O U N T E R F L A S H I N G TO D U C T A N D C A U L K ST O R M C O L L A R S E C U R E D T O D U C T CO N T I N U O U S W E L D SE E P L A N F O R DUCT SIZEMAINTAIN 2 DUCT DIAMETERSWEATHERPROOF FLEX CONNECTION VERIFY SIZE OF FAN INLET WITH FAN MANUFACTURER COVER OPENING WITH 1/2" MESH BIRD SCREEN 16 GA. WELDED STAINLESS STEEL DISCHARGE DUCT45°MINIMUM 72" ABOVE ROOF SE E P L A N F O R D U C T C O N T I N U A T I O N AN D T E R M I N A T I O N L O C A T I O N R E Q U I R E M E N T S 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTORWOMEN'S CENTER KEYPLAN NPOB 1 SCALE DATE COORD DRAWN APPROVED FILE NAMECLIENT NO. :PROJECT NO.TM WOMEN'S CENTER CARMEL, IN As indicated04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvtKPMMKCMKCHPE1.5HVAC SCHEDULES,DETAILS AND SCHEMATICS 0461BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 NO S C A L E A KI T C H E N F A N C O N T R O L S C H E M A T I C FA N S C H E D U L E TA G L O C A T I O N A R E A S E R V E D C F M T. S . P . (I N . W G . ) F A N T Y P E A R R A N G E M E N T WH E E L FA N RP M MA X . BH P MO T O R SO U N D P O W E R ( M A X . D B ) P E R O C T A V E B A N D ( N O T E : I N L E T S O U N D FO R R E T U R N A N D E X H A U S T F A N S ; O U T L E T S O U N D F O R S U P P L Y FA N S ) A C C E S S D O O R B E L T D R I V E D I R E C T D R I V E B E L T G U A R D B I R D S C R E E N O U T L E T G U A R D D R A I N G R A V I T Y B D D M O T O R I Z E D D A M P E R R O O F C U R B V I B R A T I O N I S O L A T I O N R O O F P R O T E C T I O N S Y S . U N I T M T D . D I S C . S W . A L L A L U M I N U M SPECIAL COATING WEATHER COVER WEIGHT (LBS)DESIGN REFERENCE NOTES TY P E MI N . DI A . (I N . ) H P R P M V O L T S P H A S E C Y C L E 6 3 H z 12 5 H z 2 5 0 H z 5 0 0 H z 1 0 0 0 H z 2 0 0 0 H z 4 0 0 0 H z 8 0 0 0 H z MANUFACTURER MODEL KE F - 1 R O O F C O M M U N I T Y R O O M 1 3 7 5 0 . 7 5 U T I L I T Y S E T U P B L A S T B I 1 3 " 1 4 3 0 0 . 3 5 1 / 2 1 7 2 5 4 8 0 3 6 0 8 3 7 9 7 1 7 1 6 3 6 0 5 6 5 2 N o Y e s N o Y e s Y e s Y e s Y e s N o N o Y e s Y e s N o Y e s N o No Yes 200 GREENHECK SWB-113 1 TERMINAL BOX SCHEDULE TA G CF M UN I T IN L E T SI Z E ( I N . ) DUCT RUNOUT SIZE TO UNIT (IN.)ELECTRICAL POWER NOTES MA X . MI N . CO O L I N G CF M MA X . HE A T I N G CF M MI N . HE A T I N G CF M MIN KW VOLT PHASE CYCLE TB - 1 - 1 1 4 1 1 7 5 3 5 0 1 1 7 5 6 1 0 1 0 " 1 2 " 7 . 5 4 8 0 3 6 0 S I M I L A R T O P R I C E S D V NO T E S : 1. PR O V I D E D U C T T R A N S I T I O N A T U N I T W H E R E U N I T I N L E T S I Z E A N D D U C T R U N O U T S I Z E A R E D I F F E R E N T . R E F E R T O T E R M I N A L B O X DE T A I L F O R R E Q U I R E D S T R A I G H T R U N I N T O B O X . 2. UN I T M A X I M U M P R E S S U R E D R O P I N C L U D I N G R E H E A T C O I L I S 0 . 6 " . 3. PR O V I D E L A T , B T U / H , A N D A I R P R E S S U R E D R O P I N S U B M I T T A L I N F O R M A T I O N B A S E D O N E N T E R I N G C O N D I T I O N S O F 5 5 ° F E A T A T SC H E D U L E D M I N C F M . M I N I M U M L E A V I N G A I R T E M P E R A T U R E S H A L L B E 8 0 ° F . NO SCALE B KITCHEN EXHAUST FAN DETAIL NO T E S : 1. FA N S H A L L B E U L 7 6 2 L I S T E D W I T H A N O N - S T I C K F A N W H E E L W I T H C L E A N O U T P O R T , H E A T B A F F L E , G R E A S E T R A P , D R A I N A N D WE A T H E R H O O D . MARK DATE DESCRIPTION D EX. 1. 5. 6. 7.. 9. 11. 12.. E B A B.6 732 E16 E17 E18 E15 A'' 2. 3. 8. .4 A2 5.2 5.8 F G D.6 D.3 C.9 C.6 C.4 4 C D 1 9.6 C D E B A B.6 E16 E17 E18 E15 1. 5. 6. 7.. 9. 11. 12.. A'' 2. 3. 8. 10. .4 A2 5.2 5.8 F G C.9 C.6 C.4 D.3 D.6 E B.6 732 A'' 5.2 5.8 A A2 B 9. 11. 12.. 7.. 6. 5. .4 1. E15 G F 41 FUTURE CAFE 1400 SHELL SPACE 1600 FITTING 1505 STORAGE 1506 FITTING 1507 BUS. OFFICE 1504 CASHIER 1503 SHELL SPACE 1800 COMMUNITY/ CONFERENCE ROOM 1700 DISPLAY AREA 1501 STORAGE 1508 WAITING 1200 OFFICE 1202 CONSULTATION 1201 FUTURE PHARMACY 1300 1 1/2" DHW 1" DHWR 3" DCW 1 1/2" DHW 1" DHWR 3" DCW 2" D H W 4" D C W 1 1 / 2 " D H W R SK- 2 WB-1 SK- 1 3/4" DCW 5 4 SK- 5 FWG-1 5 7 1" DHW 1" D H W 1" DHW 1" DHW 1" DHW 4 6 4 8 1" D C W 3/4" DHWR 9 9 1" DCW 2" DCW 2" V P310.5 A Sim 2" S 2" V 2" V 4" S 4" S 4" S 4" S 4" S 4" S 4" S 2" S 3" ST 2" S 4" S 4" S 4" S 2" S 3" S 4" S 2" S 6" ST 6" ST 6" ST 1 4" S 3 3 2 2" V 2" V 10 3/ 4 " D C W 1" DHW 1/2" DHWR 1" D H W 1" D H W 2" D C W 10 GENERAL NOTES: 1. NOT ALL PLAN NOTES MAY BE USED ON SHEET. 2. NO PIPING SHALL PASS THROUGH ELECTRICAL ROOMS, ELEVATOR EQUIPMENT ROOMS, STAIR SHAFTS, ELEVATOR SHAFTS OR SIMILAR SPACES UNLESS SYSTEM SERVES SPACE. 3. THE CONTRACTOR SHALL PIPE, COMPLETE AND MAKE OPERATIONAL EACH PLUMBING FIXTURE WITH WATER, WASTE AND VENT PIPES ACCORDING TO THE PLUMBING FIXTURE SCHEDULE. 4. IF A FIXTURE IS NOT INDICATED TO HAVE H&CW PIPE, W & V PIPE CONNECTED TO IT, IT SHALL BE PROVIDED AND INSTALLED. THE CONTRACTOR SHALL PROVIDE THE COST OF MATERIAL AND INSTALLATION OF THE PIPING WITHIN THEIR SCOPE OF THIS PROJECT. 5. VALVE TAGS WILL BE PLACED ON GRID FOR LOCATION OF VALVES. 6. PROVIDE THERMOSTATIC MIXING VALVE TO SERVE ANY EMERGENCY EYE WASH, EMERGENCY SHOWER REQUIRED. WALL OUTLET POWER MODULE DISPOSER PUSH BUTTON FAUCET COUNTER FIRE PROTECTION GENERAL NOTES: 1. THE EXISTING BUILDING HAS A SPRINKLER SYSTEM INSTALLED IN ALL AREAS. MODIFY EXISTING SPRINKLER HEADS, BRANCH MAINS & FEED MAIN PIPING AS REQUIRED TO ACCOMMODATE THE NEW FLOOR PLAN LAYOUT, REFLECTED CEILING LAYOUT, CEILING ELEVATION CHANGES, HVAC EQUIPMENT & DUCTWORK, ALL PIPING, AND ALL ELECTRICAL CONDUIT. 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING LAYOUT & ELEVATIONS. 3. SPRINKLER CONTRACTOR SHALL SCHEDULE SPRINKLER SHUTDOWN WITH OWNER IN ACCORDANCE WITH REQUIREMENTS OF SPECIFICATIONS & NOTIFY LOCAL FIRE DEPARTMENT OF SYSTEM & AREAS OUT OF SERVICE. FLOOR LOOP VENT ABOVE FLOOD RIM OF FIXTURE(6" MIN) PIPE SLEEVE; REFER TO PIPE PENETRATION DETAIL FOR SEALING REQUIREMENTS (DETAIL "E" ON SHEET P800.3) P-TRAP WASTE LINE WASTE LINE ROUTE VENT TO LOCATION SHOWN ON PLAN SK-1 4" S 4" V 4" S 2" V 2" V 2" V 2" S 4" S 4" S SK-5 SK-2 2" V 2" V 2" V 2" V 2" S 2" S 4" S 4" S 4" S CO 2" V 2" V FWG-1 2" S 2" V 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N POB 1 SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt KPM SAP SAP P310.5 FIRST FLOOR PLUMBING PLAN - BP5 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 1/8" = 1'-0" 1 FIRST FLOOR PLUMBING PLAN - BP5 # PLAN NOTES 1 CONNECT 2" DCW, 1" DHW, 1/2" DHWR TO EXISTING DCW, DHW, DHWR. 2 CONNECT 2" DCW, 1" DHW, 3/4" DHWR TO EXISTING DCW, DHW, DHWR. 3 CONNECT 2" V TO EXISTING V. 4 MODIFY EXISTING FP SYSTEM TO ACCOMMODATE THE NEW ARCHITECTURAL REFLECTED CEILING PLAN. 5 1/2" DHW & DCW DROP. 6 1/2" DCW, DWH DN. PROVIDE POINT OF USE GREASE INTERCEPTOR SIMILAR TO JAY R SMITH MODEL 8007. PLACE UNIT UNDER COUNTER AND CONNECT COMPLETE. 7 1/2" DCW, DHW UP TO ISLAND SINK. 8 PROVIDE SINK TOP SWITCH FOR ISLAND SINK. REFER TO DETAIL "A". 9 2" V DN. 10 2" DCW CAPPED FOR FUTURE CONNECTION. NO SCALE A PUSH BUTTON GARBAGE DISPOSAL DETAIL NO SCALE B ISLAND VENT PIPING DETAIL .Sanitary Riser Diagram BP5 (Boutique) .. Sanitary Riser Diagram BP5 (Community Room) MARK DATE DESCRIPTION D EX. 1. 5. 6. 7.. 9. 11. 12.. 13. 14. 15.. E 10 B A B.6 7 8 932 E16 E17 E18 E15 2. 3. 8. 16. 17. 18. .4 20. 19. A2 5.2 5.8 F 10.1 D.6 D.3 C.9 C.6 C.4 4 C D 1 9.5 9.6 C D E 10 B A B.6 E16 E17 E18 E15 1. 5. 6. 7.. 9. 11. 12.. A'' 2. 3. 8. 10. 13. 14. 15. 16. 17. 18. .4 20. 19. A2 9.5 5.2 5.8 F 10.1 C.9 C.6 C.4 D.3 D.6 E 10 B.6 7 8 9325.2 5.8 A A2 B 9. 11. 12.. 13. 14. 7.. 6. 5. .4 1. E15 15.. 16. 18. F 6" ST 8" ST 4" ST 6" S 4" S 4" S 4" S 4" S T 8" ST 8" S T 6" ST 6" S 6" S 4" S 4" S 6" S 8" ST 8" ST 12 " S T 4" S 8" S T 6" S 4" S 6" S 4" S 6" S 8" ST 6" S 8" S 3" S 6" S 4" S 6" S 4" S 6" S 2" S 4" S 4" S 6" S 6" S 2" S 2" S 2" S 1/2" DCW 1/2" DHW 2 3 4 2" S 6" S 6" S 7 6 4" S 10 " S T 4 2" V P310.5 B Sim 1 1 6" S 2" S GENERAL NOTES: 1. NOT ALL PLAN NOTES MAY BE USED ON SHEET. 2. NO PIPING SHALL PASS THROUGH ELECTRICAL ROOMS, ELEVATOR EQUIPMENT ROOMS, STAIR SHAFTS, ELEVATOR SHAFTS OR SIMILAR SPACES UNLESS SYSTEM SERVES SPACE. 3. THE CONTRACTOR SHALL PIPE, COMPLETE AND MAKE OPERATIONAL EACH PLUMBING FIXTURE WITH WATER, WASTE AND VENT PIPES ACCORDING TO THE PLUMBING FIXTURE SCHEDULE. 4. IF A FIXTURE IS NOT INDICATED TO HAVE H&CW PIPE, W & V PIPE CONNECTED TO IT, IT SHALL BE PROVIDED AND INSTALLED. THE CONTRACTOR SHALL PROVIDE THE COST OF MATERIAL AND INSTALLATION OF THE PIPING WITHIN THEIR SCOPE OF THIS PROJECT. 5. VALVE TAGS WILL BE PLACED ON GRID FOR LOCATION OF VALVES. 6. PROVIDE THERMOSTATIC MIXING VALVE TO SERVE ANY EMERGENCY EYE WASH, EMERGENCY SHOWER REQUIRED. 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N POB 1 SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt KPM SAP SAP P400.5 FOUNDATION SANITARY PLAN - BP5 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 1/8" = 1'-0" 1 FOUNDATION SANITARY PLAN - BP5 # PLAN NOTES 1 CONNECT 2" S TO EXISTING S. 2 1/2" DCW, DHW UP. 3 1/2" DCW, DHW UP TO ISLAND SINK. 4 2" S UP. 5 2" V DN. 6 2" V RISE. 7 (2) 2" S UP TO ISLAND SINK. REFER TO DETAIL "B" ON SHEET P310.5 FOR ISLAND VENT DETAIL. MARK DATE DESCRIPTION .. OC LC LC LC OC OC OC LC L C OC OC LC LC OC OC OC OC OC OC OC LC LC OC LC LC OC OC OC OC OC LC VS VS VS VS VS VS OC OC VS VS VS LC LC LC GENERAL NOTES: A. REFER TO SHEET E001.5 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. B. REFER TO 'A' SERIES DRAWINGS FOR ADDITIONAL INFORMATION AND ELECTRICAL SCOPE. C. PROVIDE ALL OCCUPANCY SENSORS, POWER PACKS AND RELAYS AS REQUIRED. D. DIMMING SWITCHES SHALL BE COMPATIBLE TO LED LIGHT FIXTURES. E. UNLESS NOTED OTHERWISE, MOUNT LIGHT SWITCHES, SENSORS AND DIMMERS AT +46" AFF TO CENTER. E B.6 732 A'' 5.2 5.8 A A2 B 9. 11. 12.. 7.. 6. 5. .4 1. E15 E14 41 SHELL DISPLAY AREA 1501 FITTING 1505 STORAGE 1506 FITTING 1507 STORAGE 1508 BOUTIQUE 1500 CASHIER 1503 BUS. OFFICE 1504 STORAGE 1502 COMMUNITY/ CONFERENCE ROOM 1700 SHELL SPACE 1600 SHELL SPACE 1800 F21 L9 L9 F6 F6 F6 F21 L9 L9 L9 L9 L9 L9 L9 F1 F21 F22 F22 NL NL EM EM EM cc a a a,b,c,d,e a c cc c a a a c a a a c c c c c a,b,c,d,e L11 L11 L11 F21B F21B F21B F21B F21B F21B L11 L11 L11 L11 F21B F21B F21B L11 L11 L11 L11 L11 e,f,g,n f g ge e NL e e e e,n e,n e,n e,n L9 F21 L9 F21A F21A FX L9 L9 L9 L9 L9 L9 EM a b a D b a a,b L9 L9 L9 L9 L9 L9 L9 L9 b b b b bbbb EM EM F18A FX FX d FX L13 3 5 5 5 2 NL a a a a NL 3 2 a,b 5 3 4 TYP 2 5 1 5 2 5 6 1 TYP 3 3 2 TYP 2 3 4 TYP 1 1 3 2 5 5 3 3 3 3 3 TYP TYP 1HN1- 17 1HN1- 17 e L9 e L9 L9 L9 L9 L9 NL e e e NL L9 e L9 L9 e NL F18 e F22 g F22 g F22 g 1HN1- 21 TYP 1HN1- 22 3 1HN1- 22 1HN1- 22 1HN1- 22 2 TYP f,g L13 L13 F23 F23 F23 3 a a 3 a,b a,b a,b F19 F6 F21B F21B F21 F21 F21 L9 NL 2 e e n n LVe e e e b b b b 3 b 3 L13 n L13 n L13 n L13 n n L13 n L13 n a,b F19 1HN1- 22 1HN1- 22 6 L9 e 8 7 7 7 TYP CONSULTATION 1201 WAITING 1200 OFFICE 1202 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH MEB JCP E210.5 FIRST FLOOR LIGHTING PLAN 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 PLAN NOTES 1 PROVIDE CONNECTION TO ALL EXIT LIGHTS SHOWN ON THIS FLOOR TO UNSWITCHED 20A, 1P, 277VAC CIRCUIT "1HN1-19". 2 WALL MOUNTED EMERGENCY LIGHT(S) TO BE CONNECTED UNSWITCHED TO 20A, 1P, 277VAC EXISTING CIRCUIT 1HN1-20. 3 REFER TO LIGHTING CONTROL INTENT SCHEDULE ON E600.5 FOR LIGHTING CONTROL REQUIREMENTS FOR THIS ROOM/AREA. 4 FIXTURE DESIGNATED AS `NL' TO SERVE AS NIGHT LIGHT FIXTURE AND IS TO BE CONNECTED TO UNSWITCHED 20A, 1P, 277VAC CIRCUIT "1HN1-18". 5 CONNECT LIGHT FIXTURES LOCATED IN THIS ROOM/AREA TO 20A, 1P, 277VAC CIRCUIT THROUGH OCCUPANCY SENSOR SWITCHLEG SHOWN. 6 MOUNT OVER MIRROR LIGHT FIXTURE TYPE "F19" TO +84" A.F.F. 7 WALL SWITCH STATION LC, SHALL BE WITH FIVE LOW VOLTAGE DIMMER SWITCHES "SLVDa, SLVDb, SLVDc, SLVDd AND SLVDe". 8 CONNECT TRACK LIGHT FIXTURES TYPE "L13" TO 20A, 1P, 120VAC CIRCUIT "1LN3-18" THROUGH VACANCY SENSOR SHOWN. 1/8" = 1'-0" 1 FIRST FLOOR LIGHTING PLAN MARK DATE DESCRIPTION .. J J J J J J J J J J J J J J J J J GENERAL NOTES: A. REFER TO BP5 SHEET E001.5 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. B. REFER TO HPE, H, AND P SERIES DRAWINGS FOR ADDITIONAL INFORMATION AND ELECTRICAL SCOPE. E B.6 732 A'' 5.2 5.8 A A2 B 9. 11. 12.. 7.. 6. 5. .4 1. E15 E14 41 SHELL COFFEE 1LN4 DISPLAY AREA 1501 FITTING 1505 STORAGE 1506 FITTING 1507 STORAGE 1508 BOUTIQUE 1500 CASHIER 1503 BUS. OFFICE 1504 STORAGE 1502 COMMUNITY/ CONFERENCE ROOM 1700 SHELL SPACE 1600 SHELL SPACE 1800 MSWB1 REF +44" GFCI +36" +36" +28" REF +44" GFCI +24" MICRO GFCI 1 PRINT 2 2 2 16 6 6 6 6 14 14 14 12 12 12 12 12 8 8 8 +30" +30" +30" 10 10 4 10 10 2 22 22 20 28 28 28 28 28 8 6 4 DW GD 4 10 GFCI +46" 24 5 7 28 26 8 3 OFFICE 1202 CONSULTATION 1201 WAITING 1200 13 36 18 30 18 18 36 36 36 36 30 30 30 11 20 11 12 +24"+30" +24" 10 14 TYP. +18" GFCI GB 6 TB-1-114 7.5KW 9 24 24 24 24 28 28 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH TMH JCP E310.5 FIRST FLOOR POWER PLAN 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 PLAN NOTES 1 CONNECT RECEPTACLES IN THIS AREA TO 20A, 1P, 120 VAC CIRCUIT SHOWN FROM PANEL "1LN3." 2 CONNECT RECEPTACLES IN THIS AREA TO 20A, 1P, 120 VAC CIRCUIT SHOWN FROM PANEL "1LN2." 3 MOTORIZED PROJECTION SCREEN RECESSED ON CEILING. CONNECT COMPLETE TO 20A, 1P, 120 VAC CIRCUIT BREAKER "1LN2-2" WITH THREE BUTTON (UP/DOWN/STOP) CONTROLLER MOUNTED ON WALL. MOUNT CONTROLLER AT +46" A.F.F. 4 CONNECT GARBAGE DISPOSAL TO 20A, 1P, 120 VAC CIRCUIT SHOWN THROUGH WALL MOUNTED CONTROL SWITCH. MOUNT CONTROL SWITCH AT +46" A.F.F ABOVE COUNTER. LABEL CONTROL SWITCH "GARBAGE DISPOSAL." COORDINATE EXACT LOCATION OF ROUGH-IN WITH PLUMBING TRADE. ROUTE CONDUIT FROM NEAREST WALL TO UNDER FLOOR SLAB TO DEVICE LOCATION. SAW CUT FLOOR AS REQUIRED. 5 CONNECT COOK-TOP-OVEN TO 50A, 2P, 208 VAC CIRCUIT "1LN2-10,12" WITH FEEDER SIZE 3/4"C, 2#6 + 1#10 GROUND. ALSO PROVIDE 50A, 2P, 208 VAC SHUNT TRIP BREAKER MATCHING TO EXISTING IN SPACE MADE AVAILABLE IN PANEL "1LN2." REMOVE 20A, 1P, 120 VAC BREAKERS FROM PANEL "1LN2" TO ACCOMMODATE TWO POLE SHUNT TRIP BREAKER. ROUTE CONDUIT FROM NEAREST WALL TO UNDER FLOOR SLAB TO DEVICE LOCATION. SAW CUT FLOOR AS REQUIRED. SHUNT TRIP BREAKER SHALL BE ACTIVATED BY HEAT DETECTOR IN THE HOOD. USE CIRCUIT "1LN2-34" FOR POWER TO SHUNT TRIP. 6 CONNECT DISH WASHER TO 20A, 1P, 120 VAV CIRCUIT "1LN2-16." 7 CONNECT SELF CONTAINED HOOD TO 20A, 1P, 120 VAC CIRCUIT "1LN2-18." COORDINATE EXACT LOCATION OF ROUGH-IN IN FIELD. 8 PROVIDE DUPLEX RECERPTACLE RECESSED IN CEILING FOR VIDEO PROJECTOR AND CONNECT COMPLETE TO CIRCUIT SHOWN. COORDINATE EXACT LOCATION OF RECEPTACLE WITH ARCHITECURAL CEILING GRID. 9 TERMINAL BOX. PROVIDE CONNECTION OF 480V, 3PH, 3W CIRCUIT INDICATED TO 30A, 3P CB IN PANEL 1HN2- 8,10,12 WITH FEEDER SIZE F30. REFER TO H SERIES DRAWINGS FOR TERMINAL BOX LOCATIONS AND QUANTITIES. ALSO REFER TO DETAIL ON E800. 10 CONNECT GARBAGE DISPOSAL TO 20A, 1P, 120 VAC CIRCUIT SHOWN THROUGH PUSH BUTTON CONTROL SWITCH MOUNTED ON THE COUNTER. LABEL CONTROL SWITCH "GARBAGE DISPOSAL." COORDINATE EXACT LOCATION OF PUSH BUTTON CONTROL SWITCH WITH PLUMBING TRADE. ALSO PROVIDE GFCI DUPLEX RECEPTACLE BELOW SINK FOR POWER TO GARBAGE DISPOSAL THROUGH POWER MODULE. REFER TO DETAIL A ON SHEET P310.5 FOR ADDITIONAL SCOPE OF WORK. 11 PROVIDE TWO GANG BOX AND 1"C WITH INSULATED BUSHING AND PULL STRING FROM WALL BOX TO ABOVE CEILING JUNCTION BOX LOCATED NEAR VIDEO PROJECTOR FOR DATA REQUIREMENTS. 12 BUILT-IN CONVECTION WALL OVEN MOUNTED UNDER COOK TOP OVEN. CONNECT COMPLETE TO 30A, 2P, 208 VAC CIRCUIT "1LN2-(30,32) WITH FEEDER SIZE 3/4"C, 2 # 10 + 1 # 12 GROUND. ALSO PROVIDE 30A, 2P, 208 VAC BREAKER MATCHING TO EXISTING IN SPACE MADE AVAILABLE IN PANEL "1LN2". REMOVE EXISTING 20A, 1P, 120 VAC BREAKER FROM PANEL TO ACCOMMODATE NEW BREAKER. COORDINATE LOCATION OF ROUGH-IN IN FIELD. ROUTE CONDUIT FROM NEAREST WALL TO UNDER FLOOR SLAB TO DEVICE LOCATION. SAW CUT FLOOR AS REQUIRED. 13 CONNECT RECEPTACLES IN THIS AREA TO CIRCUIT SHOWN FROM PANEL "1LN4." 14 ROUTE CONDUIT FROM NEAREST WALL TO UNDER FLOOR SLAB TO DEVICE LOCATION. SAW CUT FLOOR AS REQUIRED. 1/8" = 1'-0" 1 FIRST FLOOR POWER PLAN MARK DATE DESCRIPTION JJ J J J J J J E B.6 732 A'' 5.2 5.8 A A2 B 9. 11. 12.. 7.. 6. 5. .4 1. E15 E14 41 +44" GFCI GFCI +44" REF GFCI GFCI +44" +44" +62" +44" MICRO GFCI +44" +44" GFCI GFCI GFCI GFCI GFCI +44" +44" +44" GFCI GFCI +44" +44" +44" GFCI COPY REF GFCI MICRO +62" +44" GFCI +44" GFCI +44" GFCI GFCI GFCI GFCI +44" +44" +44" +44" COPY GFCI +44" GFCI +44" +62" +44" MICRO GFCI REF GFCI +44" GFCI +44" GFCI +44" GFCI +44" COPY GFCI +44" GFCI +44" GFCI +44" +44" GFCI +44" GFCI +44" +44" GFCI +44" GFCI GFCI +44" +44" GFCI +44" GFCI GFCI +44" TYP. FB1 FB1 FB1 +46" +46" +46" ICE PRINT +46" +46" 26,25,28 NEMA 6-30R NEMA 6-20R +46" +46" TB-1-207 TB-1-206 7,9,11 ,F30 7,9,11 ,F30 FB1 AUTO DOOR 30A/3P 30A/3P COFFEE GFCI COFFEE COFFEE +44" KEF-1 30A/3P 1/2HP WP 14HN2, F30 GENERAL NOTES: A. REFER TO SHEET E001.5 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. B. REFER TO 'A' SERIES DRAWINGS FOR ADDITIONAL INFORMATION AND ELECTRICAL SCOPE. 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH TMH JCP E320.5 SECOND FLOOR POWER PLAN 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 1/8" = 1'-0" 1 SECOND FLOOR POWER PLAN - BP5 PLAN NOTES 1 CONNECT KEF-1 TO 15A, 3P, 480 VAC SPARE BREAKER WITH FEEDER SIZE SHOWN THRU MOTOR STARTER CONTROLLER LOCATED ON THE FIRST FLOOR ELECTRICAL ROOM `1004'. REFER TO SHEET E500.5 FOR LOCATION OF PANEL AND STARTER. MARK DATE DESCRIPTION .. SD SD SD SD SD SD SD DD DD V V V V V V V V V V C V C CM C CM M C M M C C AR AR AM FA A P AM DC CR DC SD AM AM H FS TS TS DH SD C V M V A PB J C C C C V V WL E E S S S AM V J V WL WL V S GENERAL NOTES: A. REFER TO SHEET E001.5 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. B. REFER TO HPE, H, AND P SERIES DRAWINGS FOR ADDITIONAL INFORMATION AND ELECTRICAL SCOPE. C. UNLESS OTHERWISE NOTED, MOUNT FIRE ALARM MANUAL PULL STATION AT +46" AFF TO CENTER. E B.6 732 A'' 5.2 5.8 A A2 B 9. 11. 12.. 7.. 6. 5. .4 1. E15 E14 41 SHELL DISPLAY AREA 1501 FITTING 1505 STORAGE 1506 FITTING 1507 STORAGE 1508 BOUTIQUE 1500 CASHIER 1503 BUS. OFFICE 1504 STORAGE 1502 COMMUNITY/ CONFERENCE ROOM 1700 SHELL SPACE 1600 SHELL SPACE 1800 75 75 75 15 15 2 TYP. 5 TYP. 5 3 4 TYP. TYP. 1 7 15 75 1 6 6 6 +44" 4 75 TYP. CONSULTATION 1201 WAITING 1200 OFFICE 1202 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com CONNECTOR WOMEN'S CENTER KEYPLAN N SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH TMH JCP E410.5 FIRST FLOOR SYSTEMS PLAN 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 PLAN NOTES 1 PROVIDE CEILING RECESSED DATA OUTLET FOR CEILING MOUNT VIDEO PROJECTOR. PROVIDE 1" CONDUIT FROM CEILING TO JUNCTION WALL ON WALL. 2 PROVIDE ROUGH-IN IN TWO GANG BOX WITH 1"C FROM BOX TO ABOVE CEILING SPACE WITH PULL STRING FOR TELECOMMUNICATIONS (VOICE/DATA) REQUIREMENTS. 3 EXTEND EXISTING FIRE ALARM LOOP AVAILABLE IN THIS AREA TO NEW FIRE ALARM DEVICES AND CONNECT COMPLETE. 4 PROVIDE STAND ALONE PAGING SYSTEM WITH AMPLIFIER, SPEAKERS, VOLUME CONTROLLER WITH WIRING FOR BOUTIQUE AREA. PROVIDE 30 WATTS PAGING AMPLIFIER IN EXISTING IT ROOM 1002. CONNECT AMPLIFIER TO 20A, 1P, 120 VAC CIRCUIT "1LN3-16". REFER TO SHEET E500.3 FOR LOCATION 5 PROVIDE ROUGH-IN WITH SINGLE GANG BOX AND 3/4"C FROM BOX TO ABOVE CEILING SPACE WITH INSULATED BUSHING AND PULL CORD FOR STAND ALONE AUDIO VISUAL ONLY EMERGENCY HELP SYSTEM. REFER TO SHEET E500.3 FOR LOCATION OF POWER SUPPLY. 6 PROVIDE 2-GANG BOX WITH 1"C FROM BOX TO ABOVE CEILING SPACE WITH INSULATED BUSHING AND PULL STRING FOR TELECOMMUNICATION (VOICE/DATA) REQURIEMENTS. ROUTE CONDUIT FROM NEAREST WALL TO UNDER FLOOR SLAB TO DEVICE LOCATION. SAW CUT FLOOR AS REQUIRED. 7 PROVIDE "AM" RELAYWITH INTERFACE TO BUILDING FIRE ALARM SYSTEM FROM HOOD FIRE SUPPRESSION SYSTEM. 1/8" = 1'-0" 1 FIRST FLOOR SYSTEMS PLAN MARK DATE DESCRIPTION J GENERAL NOTES: A. REFER TO SHEET E001.5 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. B. REFER TO 'A' SERIES DRAWINGS FOR ADDITIONAL INFORMATION AND ELECTRICAL SCOPE. B B.6 4 B.6 B 4 120/208V BRANCH PANEL 120/208V DIST. PANEL STEP DOWN TRANSFORMER 480/277V LIGHTING PANEL 480/277V HEATING PANEL 480/277V TENANT EQUIP. PANEL FIRE ALARM NAC PANEL LIGHTING CONTROL PANEL 1LN2 1LN1 DP-1LN1 1TN1 200A/3P 200A/3P 30A/3P 30A/3P 1LCP 1HN1 1HN2 1HN3 GROUND BUS GROUND BUS 1LN1- 1 1LN1- 3 1LN1- 3 6-30R 1LN1- 6 1LN1- 8 1LN1- 10 1LN1- 12 1LN1- 2,4, (30A, 2P) 1LN1- 14 1LN1- 16 F30 1 1LN1- 18 1LN1- 20 MSWB1 F200 MSWB1 F200 ACU-4 30A/3P DDC 1LN1- 40 W +52" PAGING AMPLIFIER EMERGENCY HELP POWER SUPPLY 3 4 3 3 3 3 2MS-KEF-1 IT 1002 ELEC 1004 IT 1003 1LN3 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN As indicated 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH TMH JCP E500.5 ENLARGED ELECTRICAL ROOMS 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 1/4" = 1'-0" 1 ENLARGED FIRST FLOOR CORE ELECTRICAL AND IT ROOMS - BP5 PLAN NOTES 1 LOCATION OF PAGING AMPLIFIER. CONNECT COMPLETE TO 20A, 1P, 120VAC CIRCUIT "1LN3-20". 2 LOCATION OF MOTOR CONTROLLER STARTER MS-KEF-1. 3 UNLESS NOTED OTHERWISE ALL ELECTRICAL EQUIPMENT, DEVICES AND CIRCUITS SHOWN IN THIS ROOM /AREA ARE EXISTING AND PROVIDED UNDER CORE SHELL BID PACKAGE-3. 4 CONNECT EMERGENCY HELP POWER SUPPLY TO 20A, 1P, 120VAC CIRCUIT "1LN3-20". MARK DATE DESCRIPTION NOTES : 1. ALLOWANCE AMOUNT INDICATED INCLUDES FIXTURE, LAMP AND SHIPPING, 2. COORDINATE CEILING TYPE WITH REFLECTED CEILING PLAN AND PROVIDE APPROPRIATE FRAME FOR SPECIFIED LIGHT FIXTURE. DESCRIPTION AND PART NUMBER DOES NOT SPECIFY TYPE OF TRIM. OCCUPANCY SENSOR SCHEDULE STAND ALONE CEILING MOUNTED OCCUPANCY SENSOR. NO LIGHTING CONTROL SYSTEM INTEGRATION. AUTO ON/AUTO OFF OPERATION. 2 STAND ALONE WALL MOUNTED OCCUPANCY SENSOR WITH INTEGRAL SWITCH(ES). NO LIGHTING CONTROL SYSTEM INTEGRATION. MANUAL ON/ MANUAL OR AUTO OFF OPERATION. GENERAL NOTES: STAND ALONE CEILING MOUNTED OCCUPANCY SENSOR. NO LIGHTING CONTROL SYSTEM INTEGRATION. WALL MOUNTED LOW VOLTAGE SWITCH(ES) FOR MANUAL ON/ MANUAL OR AUTO OFF OPERATION. CONTROLLED VIA LIGHTING CONTROL SYSTEM FOR TIME ON / TIME OFF OPERATION WITH OCCUPANCY SENSOR OVERRIDE DURING TIME OFF PERIOD. LEGEND: DUAL = PASSIVE INFRARED & ULTRASONIC NOTES: 1. REFER TO PLANS FOR ADDITIONAL INFORMATION CONNECTS TO CONTROL SYSTEM VOLTAGE SENSOR SWITCHES MOUNTING OCCUPANCY SENSOR SCHEDULE c DESIGNATION PIR LINE WALL 1 NO DUAL LOW VOLT CEILING N/A NOTE 1 DESCRIPTION LIGHTING CONTROL INTENT DESIGNATION 1 2 GENERAL NOTES: A. THE INTENT OF THIS SCHEDULE IS TO IDENTIFY THE BASIC INTENT OF THE LIGHTING CONTROLS FOR EACH SPACE. PROGRAMMING SHALL BE COORDINATED WITH THE OWNER. REFER TO LIGHTING PLANS FOR ADDITIONAL CONTROL REQUIREMENTS. 3 4 LEGEND: DUAL = PASSIVE INFRARED & ULTRASONIC 5 CONTROLLED VIA LIGHTING CONTROL SYSTEM FOR TIME ON / TIME OFF. OPERATION WITH WALL MOUNTED LOW VOLTAGE SWITCH(ES) FOR MANUAL OPERATION AND OVERRIDE DURING TIME OFF PERIOD. 2 DUAL LINE WALL 2 NO NOTES: 1. REFER TO PLANS FOR ADDITIONAL INFORMATION 6 STAND ALONE CEILING MOUNTED VACANCY SENSOR. NO LIGHTING CONTROL SYSTEM INTEGRATION. LINE VOLTAGE WALL SWITCH FOR MANUAL ON/MANUAL OFF OPERATION. VACANCY SENSOR FOR AUTO OFF OPERATION. OC OC OC 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN NO SCALE 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH TMH JCP E600.5 ELECTRICAL SCHEDULES 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 BP5 LIGHT FIXTURE SCHEDULE FIXTURE TYPE FIXTURE NAME DESCRIPTION VOLTAGE LAMP MANUFACTURER EM EMERGENCY LIGHT WALL MOUNT DUAL HEAD BATTERY PACK, THERMOPLASTIC HOUSING, WHITE FINISH, WALL MOUNT, 6 VOLT, 90 MINUTE OPERATION, NICAD BATTERY, BATTERY CHARGING CIRCUIT, TEST LAMP/SWITCH, SELF DIAGNOSTICS. 277 HALOGEN DUAL-LIGHTS EZ2, LITHONIA ELM4, SURE-LITE CC, F1 DIRECT / INDIRECT TROFFER 24"Lx24"Wx5-1/2"D, COMPLETELY RECESSED FIXTURE, CENTER MOUNTED BASKET, INTEGRAL REFLECTORS WITH DETACHABLE LAMP SHIELD, PERFORATED SHIELD WITH ACRYLIC LENS INSERT, BALLAST ACCESSIBLE FROM ROOM SIDE. 277 (2) 14W T5 COLUMBIA STE, LITHONIA 2AV, METALUX 2RD1 F6 STATIC TROFFER 48"Lx24"Wx4-1/2"D, BAKED WHITE, ENAMEL FINISH, CODE, GUAGE STEEL HOUSING, FLAT STEEL DOOR, 0.125" A12 LENS. 277 (2) 28W T5 COLUMBIA 4PS, LITHONIA 2SP, METALUX 2GC F18 LINEAR WALL WASH 4"Hx3-1/2"Wx48"L, ONE PIECE STEEL HOUSING, SPECULAR REFLECTOR, MATTE BLACK DIFFUSER. 277 (1) 28W T5 FOCAL POINT FAVA-NS, LINEAR LIGHTING WW6, PINNACLE EW, PMC 533-R F18A LINEAR WALL WASH 4"Hx3-1/2"Wx48"L, ONE PIECE STEEL HOUSING, SPECULAR REFLECTOR, MATTE BLACK DIFFUSER, 0-10V ELECTRONIC DIMMING BALLAST. 277 (1) 28W T5 FOCAL POINT FAVA-NS, LINEAR LIGHTING WW6, PINNACLE EW, PMC 533-R F19 WALL MOUNT OVER MIRROR LIGHT 24"x6-7/8"Dx3-1/2"H, STEEL HOUSING, WHITE PAINTED FINISH, A12 ACRYLIC LENS, DOWNLIGHT ONLY. (2) 14W T5 LITHONIA WP, METALUX BA, LUMAX BF F21 DIRECT / INDIRECT TROFFER 48"Lx24"Wx5-1/2"D, COMPLETELY RECESSED FIXTURE, CENTER MOUNTED BASKET, INTEGRAL REFLECTORS WITH DETACHABLE LAMP SHIELD, PERFORATED SHIELD WITH ACRYLIC LENS INSERT, BALLAST ACCESSIBLE FROM ROOM SIDE. 277 (2) 28W T5 COLUMBIA STE, LITHONIA 2AV, METALUX 2RD1 F21A DIRECT / INDIRECT TROFFER 48"Lx24"Wx5-1/2"D, COMPLETELY RECESSED FIXTURE, CENTER MOUNTED BASKET, INTEGRAL REFLECTORS WITH DETACHABLE LAMP SHIELD, PERFORATED SHIELD WITH ACRYLIC LENS INSERT, ELECTRONIC BALLAST W/ 50% STEP DIMMING, BALLAST ACCESSIBLE FROM ROOM SIDE. 277 (2) 28W T5 COLUMBIA STE, LITHONIA 2AV, METALUX 2RD1 F21B DIRECT / INDIRECT TROFFER 48"Lx24"Wx5-1/2"D, COMPLETELY RECESSED FIXTURE, CENTER MOUNTED BASKET, INTEGRAL REFLECTORS WITH DETACHABLE LAMP SHIELD, PERFORATED SHIELD WITH ACRYLIC LENS INSERT, 0-10V ELECTRONIC DIMMING BALLAST, BALLAST ACCESSIBLE FROM ROOM SIDE. 277 (2) 28W T5 COLUMBIA STE, LITHONIA 2AV, METALUX 2RD1 F22 PENDANT LIGHT 13.8"H x 4.3" DIAMETER GLASS CYLINDRICAL PENDANT, OPAL GLASS DIFFUSER, CANOPY MOUNTED BALLAST, FIELD CUTTABLE CORD, SATIN NICLEL FINISH. REFER ARCHITECTURAL ELEVATIONS AND DETAILS FOR PENDANT SUSPENSION CABLE LENGTH. 277 QSX24Q-3 (3) 32W TRT ALLOWANCE AMOUNT OF $410 PER EACH NOTE 1. (LBL LIGHTING, PF229-OP-SC-32T) F23 LINEAR DOWN LIGHT 4"Hx3-1/2"Wx48"L, ONE PIECE STEEL HOUSING, SPECULAR REFLECTOR, OPAQUE SATIN FLUSH LENS. 277 (1) 28W T5 FOCAL POINT FAVB, PINNACLE EV3A, ZUMTOBEL SCON41 FX EXIT LIGHT DIE-CAST ALUMINUM EXIT, WHITE HOUSING DIRECTIONAL ARROWS, UNIVERSAL MOUNT, STENCIL FACE, GREEN LETTER, BATTERY, BATTERY CHARGING CIRCUIT, SELF DIAGNOSTIC. 277 LED DUAL-LITE SE, LITHONIA LE, SURE-LITES CX L9 LED DOWNLIGHT 6" DIA. RECESSED DOWN LIGHT, SELF TRIM, 1800 DELIVERED LUMENS, 3500K COLOR TEMPERATURE RATED FOR 50,000 HOURS AT 70% LUMENS MAINTENANCE, WITH DIMMING MODULE. 277 LED GOTHAM A LED, PORTFOLIO 6LW, PRESCOLITE D6LED L11 LED DOWNLIGHT 6" DIA. RECESSED DOWN LIGHT, SELF TRIM, 1000 DELIVERED LUMENS, 3500K COLOR TEMPERATURE RATED FOR 50,000 HOURS AT 70% LUMENS MAINTENANCE, WITH DIMMING MODULE. 277 LED GOTHAM A LED, PORTFOLIO 6LW, PRESCOLITE D6LED L13 LED TRACK LIGHT MACHINED ALUMINUM HOUSING WITH MATTE CHROME FINISH. MOUNTED ON TRACK SYSTEM. POST ALZAK ANODIZED ALUMINUM REFLECTOR. 120 LED BRUCK 350, DEL 406, ORBIS OB1 THIS PANEL WAS PROVIDED IN THE PREVIOUS CORE AND SHELL PACKAGE (BP#3). SHOWN FOR REFERENCE ONLY UNLESS OTHERWISE NOTED TO ILLUSTRATE CIRCUITING INFORMATION. Remarks: Total Connected Load (Amps): 24.5 A Total Connected Load 8.8 kVA Total Load: 3.4 kVA 4.3 kVA 1.1 kVA 41 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 42 39 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 40 37 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 38 35 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 36 33 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 34 31 SPARE 20 A 1 0.0 0.0 -- -- -- 32 29 SPARE 20 A 1 0.0 0.0 2 30 A WALL OVEN - COMMUNITY ROOM 30 27 SPARE 20 A 1 0.0 1.4 1 20 A Receptacle - COMMUNITY ROOM 1700 28 25 SPARE 20 A 1 0.0 0.8 1 20 A Receptacle - COMMUNITY ROOM 1700 26 23 SPARE 20 A 1 0.0 0.9 1 20 A Receptacle - COMMUNITY ROOM 1700 24 21 SPARE 20 A 1 0.0 0.4 1 20 A Receptacle - COMMUNITY ROOM 1700 22 19 SPARE 20 A 1 0.0 0.4 1 20 A Receptacle - COMMUNITY ROOM 1700 FB 20 17 SPARE 20 A 1 0.0 0.0 1 20 A HOOD - COMMUNITY ROOM 18 15 SPARE 20 A 1 0.0 1.4 1 20 A COMMUNITY ROOM 1700 DISHWASHER 16 13 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 14 11 SPARE 20 A 1 0.0 0.0 -- -- -- 12 9 SPARE 20 A 1 0.0 0.0 2 50 A COOK TOP OVEN - COMMUNITY ROOM 10 7 SPARE 20 A 1 0.0 1.0 1 20 A Receptacle - COMMUNITY ROOM 1700 8 5 SPARE 20 A 1 0.0 0.2 1 20 A COMMUNITY ROOM 1700 GARBAGE 6 3 SPARE 20 A 1 0.0 1.1 1 20 A COMMUNITY ROOM 1700 GARBAGE 4 1 SPARE 20 A 1 0.0 1.2 1 20 A COMMUNITY ROOM 1700 PROJECTOR 2 Circuit Number Circuit Description Trip Poles A B C Poles Trip Circuit Description Circuit Number General Panel Comments: Enclosure Type: Type 1 Ground: YES Main Rating: 225 A Mounting: Surface Wire: 4 Main Type: MLO Supplied From: DP-1LN1 Phase: 3 A.I.C. Rating: 10 KAIC Location: ELEC. 1004 Voltage: 120/208 Wye Branch: NORMAL Branch Panel: 1LN2 THIS PANEL WAS PROVIDED IN THE PREVIOUS CORE AND SHELL PACKAGE (BP#3). SHOWN FOR REFERENCE ONLY UNLESS OTHERWISE NOTED TO ILLUSTRATE CIRCUITING INFORMATION. Remarks: Total Connected Load (Amps): 24.8 A Total Connected Load 8.9 kVA Total Load: 2.7 kVA 4.4 kVA 1.8 kVA 41 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 42 39 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 40 37 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 38 35 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 36 33 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 34 31 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 32 29 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 30 27 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 28 25 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 26 23 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 24 21 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 22 19 SPARE 20 A 1 0.0 0.0 1 20 A EMERGENCY HELP, PAGING AMP - IT 1002 20 17 SPARE 20 A 1 0.0 0.0 1 20 A TRACK LIGHTS - DISPLAY AREA 1501 18 15 SPARE 20 A 1 0.0 1.4 1 20 A Receptacle - CASHIER 1503 16 13 SPARE 20 A 1 0.0 0.7 1 20 A Receptacle - STORAGE 1508 14 11 SPARE 20 A 1 0.0 0.9 1 20 A Receptacle - ROOMS 1505, 1506, & 1507 12 9 SPARE 20 A 1 0.0 2.2 1 20 A Receptacle - CASHIER 1503 PRINTER 10 7 SPARE 20 A 1 0.0 1.1 1 20 A Receptacle - DISPLAY AREA 1501 8 5 SPARE 20 A 1 0.0 0.9 1 20 A Receptacle - BUS. OFFICE 1504 6 3 SPARE 20 A 1 0.0 0.8 1 20 A Receptacle - DISPLAY AREA 1501 4 1 SPARE 20 A 1 0.0 0.9 1 20 A Receptacle - CASHIER 1503 2 Circuit Number Circuit Description Trip Poles A B C Poles Trip Circuit Description Circuit Number General Panel Comments: Enclosure Type: Type 1 Ground: YES Main Rating: 100 A Mounting: Surface Wire: 4 Main Type: MLO Supplied From: DP-1LN1 Phase: 3 A.I.C. Rating: 10 KAIC Location: ELEC. 1004 Voltage: 120/208 Wye Branch: NORMAL Branch Panel: 1LN3 THIS PANEL WAS PROVIDED IN THE PREVIOUS CORE AND SHELL PACKAGE (BP#3). SHOWN FOR REFERENCE ONLY UNLESS OTHERWISE NOTED TO ILLUSTRATE CIRCUITING INFORMATION. Remarks: Total Connected Load (Amps): 27.7 A Total Connected Load 23.1 kVA Total Load: 3.9 kVA 10.1 kVA 9.1 kVA 41 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 42 39 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 40 37 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 38 35 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 36 33 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 34 31 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 32 29 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 30 27 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 28 25 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 26 23 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 24 21 Lighting RM. 1700 20 A 1 1.3 1.2 1 20 A Lighting 22 19 Exit Lighting 20 A 1 0.0 0.2 1 20 A EM Battery Pack Lighting 20 17 Lighting 20 A 1 3.6 0.4 1 20 A Lighting - NL 18 15 Lighting 20 A 1 3.0 1.4 1 20 A Lighting 16 13 Lighting 20 A 1 0.6 0.0 1 20 A Lighting 14 11 Lighting 20 A 1 3.4 0.5 1 20 A Lighting 12 9 Lighting 20 A 1 1.3 0.0 1 20 A Other 10 7 Lighting 20 A 1 1.3 0.4 1 20 A Lighting 8 5 Lighting 20 A 1 0.7 0.5 1 20 A Other 6 3 Lighting 20 A 1 1.5 0.5 1 20 A Other 4 1 Lighting 20 A 1 1.2 0.2 1 20 A Lighting 2 Circuit Number Circuit Description Trip Poles A B C Poles Trip Circuit Description Circuit Number PROVIDE WITH DOUBLE LUGS. General Panel Comments: Enclosure Type: Type 1 Ground: YES Main Rating: 225 A Mounting: Surface Wire: 4 Main Type: MLO Supplied From: MSWB1 Phase: 3 A.I.C. Rating: 22 KAIC Location: ELEC. 1004 Voltage: 480/277 Wye Branch: NORMAL Branch Panel: 1HN1 MOTOR CONTROLLER SCHEDULE Designation Load Served Location Equipment Data Starter Data Nema Enclosure Comments HP FLA Voltage Phase Circuit Breaker Starter Frame Size Trip Size Type NEMA Size MS-KEF1 KEF-1 ELEC 1004 1/2 1.1 480 3 30 15 FVNR 1 1 POWER TO SHUNT TRIP MARK DATE DESCRIPTION SUPPORT STRUCTURE NOTE: FOR STEEL STRUCTURAL SYSTEM COMBINATION BEAM CLAMP AND CONDUIT HANGER OR EQUIVALENT NOTE: 1. FOR STEEL STRUCTURAL SYSTEM. 2. PROVIDE SEISMIC BRACING MINIMUM 40' ON CENTER WHEN THE CONDUITS SUPPORT IS BELOW 12" FROM STRUCTURE. UNISTRUT CHANNEL OR EQUIVALENT CONDUIT CLAMP OR EQUIVALENT SIZE AS REQUIRED THREADED ROD SIZE AS REQUIRED BEAM CLAMP STRUTCLAMP OR EQUIVALENT BEAM CLAMP STEEL CABLE AIRCRAFT HANGER WIRE STEEL CABLE AIRCRAFT HANGER WIRE LAY-IN CEILING LAY-IN CEILING FLEXIBLE CONDUIT W/#14 WIRE (6' MAX.) LAY-IN CEILING JUNCTION BOX LAY-IN CEILING 12 GAUGE HANGER WIRE OR CHAIN FOR FIXTURE SUPPORT CONNECTED TO STRUCTURE ABOVE SEISMIC CLIP WALL CONDUIT VANITY SINK LIGHT FIXTURE MIRROR 4"x4" BOX: VERIFY MOUNTING AHEIGHT AND EXACT LOCATION PRIOR TO ROUGH-IN 6" . CADDY SCREW GUN BRACKET NOTE: FOR METAL STUD WALL CONSTRUCTION ONLY. 4" SQUARE BOX METAL STUDS CONDUIT BOX MOUNTING BRACKET 9365 Counselors Row Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com SCALE DATE COORD DRAWN APPROVED FILE NAME CLIENT NO. : PROJECT NO. TM WOMEN'S CENTER CARMEL, IN NO SCALE 04610082 04610082-MEP_BSALS_CENTRAL_v2012.rvt BDH TMH JCP E800.5 ELECTRICAL DETAILS 0461 BP #5 DESIGN DOCUMENTS SEPTEMBER 12, 2014 NO SCALE 1 2" AND SMALLER CONDUIT SUPPORT DETAIL NO SCALE 2 2-1/2" AND LARGER CONDUIT SUPPORT DETAIL NO SCALE 3 LAY-IN FIXTURE DETAIL NO SCALE 4 OVER MIRROR LIGHT FIXTURE INSTALLATION DETAIL NO SCALE 5 WALL BOX INSTALLATION DETAIL MARK DATE DESCRIPTION