Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
15010047 Building Plans
VICINITY MAP ARCHITECT OWNER MEP TENANT FIT OUT 1215 S. RANGELINE RD CARMEL, IN 46032 CR architecture + design 600 VINE STREET SUITE 2210 CINCINNATI, OHIO 45202 T: (513) 721-8080 F: (513) 721-8181 TEMPORARY KROGER STORE FOR # J-959 PROJECT SITE 1 A2.1 1 A2.1 1 1 100 1 1 A MATERIAL and SYMBOL LEGEND 1. ALL WORK SHALL BE DONE IN AN APPROVED WORKMANLIKE MANNER AND SHALL BE IN COMPLIANCE WITH GOVERNING CODES & REGULATORY AGENCIES. 2. GENERAL CONTRACTOR SHALL OBTAIN BLDG PERMIT. CONTRACTOR SHALL OBTAIN ALL OTHER PERMITS. 3. ALL EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE MADE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 4. TEMPORARILY BRACE THE ENTIRE STRUCTURE AS REQUIRED TO MAINTAIN STABILITY UNTIL IT IS COMPLETE AND FUNCTIONING PER THE DESIGN INTENT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 5. COORDINATE DIMENSIONS FOR EQUIPMENT SUPPORTS, WALL, FLOOR OR ROOF OPENINGS WITH APPLICABLE TRADE CONTRACTORS PRIOR TO STEEL FABRICATION OR CONCRETE PLACEMENT. 6. SPRINKLER DRAWINGS WILL BE SUBMITTED UNDER SEPARATE COVER BY A LICENSED SPRINKLER CONTRACTOR IN THE STATE OF INDIANA. 7. FIRE ALARM DRAWINGS WILL BE SUBMITTED UNDER SEPARATE COVER BY A LICENSED CONTRACTOR IN THE STATE OF INDIANA. 8. EXISTING DRAWINGS PREPARED BY CR ARCHITECTURE + DESIGN , DATED 08/03/11, WERE USED IN THE PREPARATION OF THESE CONSTRUCTION DOCUMENTS. CR architecture + design MAKES NO WARRANTIES EITHER EXPRESSED OR IMPLIED FOR ANY EXISTING DOCUMENTS PROVIDED AS REFERENCE MATERIAL REGARDING THEIR USABILITY OR FITNESS FOR ANY PARTICULAR USE. XX'-X" JST BRG SECTION CUT TAG DETAIL TAG SECTION NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER WALL TYPE TAG WINDOW TAG DOOR TAG REVISION TAG KEYNOTE SYMBOL ELEVATION TAG COLUMN REFERENCE GRIDS ELEVATION NUMBER SHEET NUMBER XX-XXX INTERIOR WALL UNIT (CMU) CONCRETE EARTH BATT INSULATION RIGID INSULATION STEEL ALUMINUM ROUGH LUMBER BLOCKING SAND KROGER - CENTRAL 5960 CASTLEWAY WEST DRIVE INDIANAPOLIS, IN 46250 G0.1 COVER SHEET DRAWING INDEX GENERAL NOTES INDEX OF DRAWINGS BI D / P E R M I T IS S U E 12 / 0 8 / 2 0 1 4 G0.1 COVER SHEET/ DRAWINGS INDEX X CIVIL C0.1 SITE PLAN - FOR REFERENCE ONLY X ARCHITECTURAL AD1.1 FLOOR PLANS + DEMO PLANS X A4.1 FINISH PLAN, DOOR SCHEDULE + DETAILS X A5.2 STANDARD DETAILS X PLUMBING P0.1 PLUMBING COVER SHEET X PD1.1 PLUMBING WASTE & VENT DEMOLITION PLAN X PD1.2 PLUMBING DOMESTIC WATER & GAS DEMOLITION PLAN X P1.1 PLUMBING WASTE & VENT PLAN X P1.2 PLUMBING DOMESTIC WATER & GAS PLAN X P5.1 PLUMBING DETAILS X P5.2 PLUMBING DETAILS X P5.3 PLUMBING DETAILS X P5.4 PLUMBING DETAILS X P5.5 PLUMBING DETAILS X P6.1 PLUMBING SCHEDULES X MECHANICAL M0.0 HVAC COVER SHEET X MD1.1 HVAC DEMOLITION PLAN X M1.1 HVAC FLOOR PLAN X ELECTRICAL E0.0 ELECTRICAL COVER SHEET X ED1.1 ELECTRICAL LIGHTING DEMOLITION PLAN X ED1.2 ELECTRICAL POWER DEMOLITION PLAN X E1.1 ELECTRICAL LIGHTING PLAN X E1.3 ELECTRICAL POWER PLAN X E5.1 ELECTRICAL DETAILS X E6.2 ELECTRICAL SINGLE LINE DIAGRAM X E6.2.1 ELECTRICAL PANEL SCHEDULES X ENERGY MANAGEMENT EM0.0 ENERGY MANAGEMENT COVER SHEET X EM1.1 ENERGY MANAGEMENT PLAN X EM5.1 ENERGY MANAGEMENT DETAILS X EM5.2 ENERGY MANAGEMENT DETAILS X EM5.3 ENERGY MANAGEMENT DETAILS X EM5.4 ENERGY MANAGEMENT DETAILS X SYSTEMS ET1.1 SYSTEMS PLAN X FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : T u e s d a y , D e c e m b e r 0 9 , 2 0 1 4 1 : 5 3 : 2 9 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 DAVID R. JOHNSON LICENSE # 11100020 EXPIRES 12/31/2015 KAP KAP CR architecture + design 600 VINE STREET SUITE 2210 CINCINNATI, OHIO 45202 T: (513) 721-8080 F: (513) 721-8181 CODE INFORMATION PROJECT DESCRIPTION C0.1 SITE PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : T u e s d a y , D e c e m b e r 0 9 , 2 0 1 4 1 0 : 0 9 : 1 3 A M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 DAVID R. JOHNSON LICENSE # 11100020 EXPIRES 12/31/2015 XXX XXX XXX XXX KAP KAP LOCATION MAP E 106TH ST N M E R I D I A N S T 465 31 E 116TH ST CARMEL DR S R A N G E L I N E R D KE Y S T O N E P K W Y PROPOSED SITE PLAN FOR REFERENCE ONLY - NOT FOR CONSTRUCTION PER LIQUOR PERMIT REQUIREMENTS: CONTRACTOR TO PROVIDE AND INSTALL CANOPY/AWNING BETWEEN THE STORE AND THE ENTRY TO THE PHARMACY TRAILER. CANOPY TO BE SELF SUPPORTING AND SECURED TO GROUND. REMOVE UPON REMOVAL OF PHARMACY TRAILER. CONTRACTOR TO RUN NEW T1 LINE FROM EXISTING KROGER STORE TO NEW UTILITY POLE (PROVIDED AND INSTALLED BY CONTRACTOR) AND FROM UTILITY POLE TO TEMPORARY KROGER. COORDINATE LOCATIONS OF POLE AND T1 LINE WITH KROGER/CITY OF CARMEL/UTILITY DEPARTMENT KROGER TO PROVIDE AND CONTRACTOR TO INSTALL SCREENING SURROUNDING NEW GENERATOR. SCALE: 3/32"=1'-0" 1 A1.1 DEMO FLOOR PLAN E 1 2 3 4 D C B A REMOVE EXISTING DOOR. FRAME TO BE CONVERTED TO ACCEPT DOUBLE ACTING DOOR AT AREA TO BECOME PRODUCE PREP: FLOOR: INSTALL VCT AS REQUIRED TO PROVIDE LEVEL SURFACE FOR NEW SHEET FLOORING BASE: REMOVE EXISTING VINYL BASE WALLS: REMOVE EXISTING LOOSE WALL COVERING AND CASEWORK BUILD-OUTS. CEILING: REMOVE EXISTING CEILING PADS. CEILING GRID TO REMAIN. AT AREA TO BECOME MEAT PREP: FLOOR: INSTALL VCT AS REQUIRED TO PROVIDE LEVEL SURFACE FOR NEW SHEET FLOORING BASE: REMOVE EXISTING VINYL BASE WALLS: REMOVE EXISTING LOOSE WALL COVERING AND CASEWORK BUILD-OUTS. CEILING: REMOVE EXISTING LIGHTING AS REQUIRED. RE: ELECTRICAL DRAWINGS EXISTING BACKROOM WALLS/FINIAHES TO REMAIN. REMOVE MISCELLANEOUS ITEMS AS REQUIRED FOR INSTALLTION OF NEW COOLERS/PREP ROOMS, SUSPENDED REFRIGERATION EQUIPMENT, ELECTRIC EQUIPMENT AND EVAC SYSTEM. MAINTAIN EMERGENCY EGRESS DURING CONSTRUCTION. AT AREA TO BECOME BREAK ROOM: FLOOR: EXISTING FLOOR TO REMAIN. REMOVE AND REPLACE FLOORING AS REQUIRED DUE TO CONSTRUCTION. BASE: REMOVE EXISTING VINYL BASE WALLS: REMOVE EXISTING WALL COVERING AND CASEWORK BUILD-OUTS. CEILING: EXISTING CEILING AND LIGHTING TO REMAIN. AT AREA TO BECOME CLOSET: FLOOR: EXISTING FLOOR TO REMAIN. REMOVE AND REPLACE FLOORING AS REQUIRED DUE TO CONSTRUCTION. BASE: EXISTING VINYL BASE TO REMAIN. WALLS: EXISTING WALL FINISHES TO REMAIN. CEILING: EXISTING CEILING AND LIGHTING TO REMAIN U.N.O. ON CEILING PLANS AT OFFICES: FLOOR: EXISTING FLOOR TO REMAIN. REMOVE AND REPLACE FLOORING AS REQUIRED DUE TO CONSTRUCTION. PATCH TO MATCH EXISTING AS REQUIRED BASE: REMOVE EXISTING VINYL BASE. WALLS: REMOVE EXISTING WALL FINISHES. PREPARE FOR NEW PAINT. CEILING: EXISTING CEILING AND LIGHTING TO REMAIN. CEILING GRID AND TILES TO BE PATCHED AT REMOVED WALL REMOVE EXISTING WALL, INCLUDING BRACING AND SUPPORTS, SEPARATING OFFICES. AT AREA TO BECOME CLOSET: FLOOR: EXISTING FLOOR TO REMAIN. REMOVE AND REPLACE FLOORING AS REQUIRED DUE TO CONSTRUCTION. BASE: EXISTING VINYL BASE TO REMAIN. WALLS: EXISTING WALL FINISHES TO REMAIN. CEILING: EXISTING CEILING AND LIGHTING TO REMAIN U.N.O. ON CEILING PLANS REMOVE EXISTING WALLS, INCLUDING BRACING AND SUPPORTS, SEPARATING OFFICES. PORTIONS OF EXISTING WALLS TO BE CONVERTED TO SOFFIT. RE: 23/A5.2 & 24/A5.2 FOR SOFFIT INFORMATION. EXISTING WIDE BULKHEAD TO BE CONVERTED TO SINGLE DROP SOFFIT. RE: 23/A5.2 & 24/A5.2 FOR SOFFIT INFORMATION. EXISTING WALL HEATER TO BE ROTATED IN WALL TO SERVE HALL. CREATE OPENING IN HALL WALL AS REQUIRED AND PATCH EXISITNG OPENING IN FORMER BREAKROOM. REMOVE AND SALVAGE EXISTING DOOR. FRAME TO REMAIN REMOVE AND SALVAGE EXISTING DOOR. FRAME TO REMAIN REMOVE DOOR AND FRAME FOR WALL TO BE INFILLED. AT EXISTING BREAKROOM: REMOVE ALL CASEWORK, FIXTURES, FLOOR AND WALL FINISHES AND PREPARE FOR NEW. REMOVE CEILING GRID, PANELS, LIGHTING AND ALL SUPPORTS. EXISTING RESTROOMS TO REMAIN AS-IS THROUGHOUT SALES, REMOVE EXISTING WALL BASE AND VINYLS APPLIED TO WALLS AND SOFFITS. EXISTING FLOORING TO REMAIN AND BE PATCHED AS REQUIRED DUE TO NEW WORK. AT EXISTING PHARMACY: REMOVE ALL CASEWORK, FIXTURES, FLOOR AND WALL FINISHES AND PREPARE FOR NEW. CEILING AND LIGHTING TO REMAIN U.N.O. ON CEILING AND ELECTRICAL PLANS. EXISTING DRIVE-UP WINDOW TO REMAIN. REMOVE AND SALVAGE EXISTING PNEUMATIC TUBE SYSTEM TO ABOVE EXISTING CEILING. PATCHCEILING AS REQUIRED. THROUGHOUT SALES, REMOVE AND CAP EXISTING ELECTRICAL STUB-UPS. PATCH FLOORING AS REQUIRED. RE: ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. GENERAL DEMOLITION NOTE AT ALL AREAS OF NEW/REMOVED CASEWORK AND MEP, NEW BLOCKING IN EXISTING WALLS AND/OR CEILINGS, AND LOCATIONS OF REMOVED WALLS: REMOVE SHEATHING, STUDS, AND/OR CEILING GRID AND PANELS AS REQUIRED. PATCH CEILING AND WALLS TO MATCH EXISTING AS REQUIRED. REMOVE PORTION OF WALL REMOVE PORTION OF WALL FOR INSTALLATION OF NEW DAIRY COOLER. DROP SOFFIT TO REMAIN. COORDINATE WALL WITH DAIRY COOLER DIMENSIONS REMOVE EXISTING WALL HEATER AND PATCH WALL SCALE: 3/32"=1'-0" 3 A1.1 FLOOR PLAN E 1 2 3 4 D C B A 17 17 25 25 25 25 25 25 17 5 2 103 102 106 113 115 EXISTING DRIVE-UP WINDOW TO REMAIN. REMOVE AND BLOCKING NOTES ·PROVIDE WOOD BLOCKING AT NEW CASEWORK AND WALL MOUNTED EQUIPMENT. 119 ACCT. 118 CUSTOMER SERVICE 120 CHECKLANES 100 SALES 117 MEN 116 WOMEN 114 STORAGE 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 101 HALL "C" 104 MEAT PREP 102 PRODUCE PREP 111 JANITOR'S CLOSET NEW DOUBLE ACTING DOOR IN EXISTING HOLLOW METAL FRAME. CONVERT FRAME AS REQUIRED. VERIFY DOOR SIZE IN FIELD. 104 5 2 INSTALL PAPER TOWEL AND SOAP DISPENSERS AT EACH HANDSINK, TYP. INSTALL PROPORTIONERS AT EACH PREP SINK, TYP. REPAIR EXISTING SHEATHING IN ALCOVE 1" 1" 1" 17 109 FRAME WALL FOR NEW DOOR AND FRAME. RE: A4.1 FOR DOOR SIZE. EDGE OF DOOR TO ALIGN WITH EDGE OF EXISTING OPENING. FRAMING NOTES ·AT NEW WALLS ALIGNING WITH EXISTING MATCH EXISTING WALL THICKNESS. CONSTRUCTION SCOPE ·ALL WALLS REMOVED FOR CONSTRUCTION OF SPACE ARE TO BE REPLACED FOLLOWING CLOSING OF TEMPORARY KROGER. ·ALL WALLS AND COOLERS CONSTRUCTED FOR TEMPORARY KROGER ARE TO BE REMOVED FOLLOWING CLOSING OF TEMPORARY KROGER. 111 PROVIDE AND INSTALL LOCKABLE CHAINLINK ENCLOSURE FOR DATA EQUIPMENT 8' - 0 " 4'-0" REMOVE AND REPLACE CONCRETE FOR INSTALLATION OF SANITARY LINES. RE: PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. PORTIONS OF EXISTING WALLS TO BE CONVERTED TO SOFFIT. RE: 23/A5.2 & 24/A5.2 FOR SOFFIT INFORMATION. MATCH HEIGHT OF EXISTING SOFFIT. EXISTING WIDE BULKHEAD TO BE CONVERTED TO SINGLE DROP SOFFIT. RE: 23/A5.2 & 24/A5.2 FOR SOFFIT INFORMATION. MATCH HEIGHT OF EXISTING SOFFIT RETURN EXISTING 7'-6" AFF SOFFIT BACK TO WALL. ALIGN INFILL WALL TO MATCH EXISTING AT REMOVED DOOR PATCH WALL AND REWORKED WALL HEATER INSTALL OPAQUE FILM ON WINDOW. REMOVE AFTER CLOSING OF TEMPORARY KROGER INSTALL PRE-FABRICATED CUSTOMER SERVICE AND ACCOUNTING WALLS, DOORS AND FIXTURES 6' - 1 " ± INSTALL NEW EAS PEDESTALS AT EACH DOOR NEW GENERATOR. RE: ELECTRICAL DRAWINGS INSTALL PLATE OVER DEAL DRAWER DURING USE AS TEMPORARY KROGER. DOOR TAG HEIGHT MODIFIER WALL TAG WALL MODIFIER NEW STUD WALL COOLER PANEL WALL FLOOR PLAN LEGEND 16" 8'-9" XXX CONCRETE LEGEND EXISTING WALL TO REMAIN. EXISTING ITEM TO REMAIN. EXISTING WALL TO BE REMOVED. EXISTING ITEM TO BE REMOVED. DOOR AND FRAME TO BE REMOVED COMPLETE WITH ALL HARDWARE. DOOR TO REMAIN. DEMOLITION LEGEND AREA OF CONCRETE TO BE REMOVED AND REPLACED WITH GRAY CONCRETE SMOOTH FINISH. WHEN PLACING NEW CONCRETE, DOWEL INTO ADJACENT SLAB W/ #4 BARS @ 24" O.C. RE ASD-69 FOR ADDITIONAL INFORMATION 1. ALL INSULATED PANELS ARE PROVIDED BY KROGER 2. ALL INTERIOR DIMENSIONS ARE TO FACE OF SUBSTRATE. 3. ALL METAL STUDS IN INTERIOR PARTITIONS TO BE 3 5/8" UNLESS OTHERWISE NOTED. REFER TO A4.1 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 4. ALL GWB, MR BD, CEMENTITIOUS BACKER BD AND INTERIOR FRT PLYWD IS TO MATCH EXISTING THICKNESS. 5. REFER TO SHEET A4.1 FOR WALL TYPES. 6. REFER TO SHEETS A5.2 FOR ASD STANDARD DETAILS. WALL FINISHES: 7. ALL FINISHES TO WRAP RETURNS AND TERMINATE ACCORDINGLY, UNLESS NOTED OTHERWISE. 8. ALL FINISHES SHALL TERMINATE 6" BEHIND LINE OF SIGHT AT PERMANENT FIXTURES OR CASEWORK. 9. ALL PAINT SHALL BE PROVIDED BY CONTRACTOR, UNLESS NOTED OTHERWISE. 10. VENTS, ELECTRICAL PANELS AND DOORS TO BE PAINTED SATIN FINISH ENAMEL. COLOR TO MATCH ADJACENT WALL FINISH, UNLESS NOTED OTHERWISE. 11. PROVIDE CONTROL JOINTS IN GB AS REQUIRED. GENERAL NOTES GENERAL DEMOLITION NOTES A. ITEMS SHOWN AS DASHED ARE TO BE REMOVED UNLESS NOTED OTHERWISE. REFER TO PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION AND PATCHING BY THE GENERAL CONTRACTOR. B. THE OWNER AND/OR LANDLORD SHALL RESERVE THE RIGHT TO CLAIM ANY MATERIALS THAT ARE BEING DEMOLISHED PRIOR TO THE CONTRACTOR DISPOSING OF THEM OFF SITE. C. "FLOORING" DENOTES FLOOR COVERING MATERIALS, INCLUDING BACKINGS, ADHESIVES, DOWN TO, BUT EXCLUSIVE OF, FLOOR SLABS, STRUCTURAL SLABS AND STRUCTURAL MATERIALS, UNLESS NOTED OTHERWISE. D. "CEILING" DENOTES CEILING MATERIALS INCLUDING SUSPENSION SYSTEMS, ADHESIVE RESIDUALS, MOLDINGS, UP TO BUT EXCLUSIVE OF STRUCTURAL MATERIALS. E. CMU OR CONCRETE WALLS TO BE REMOVED SHALL BE REMOVED TO A POINT 2 IN.(MIN.) BELOW THE EXISTING FLOOR SLAB (UNLESS SETTING ON SLAB). PATCH WITH NEW CONCRETE TO BE FLUSH WITH THE EXISTING FLOOR SLAB. F. AFTER THE DEMOLITION OF MATERIALS, THE CONTRACTOR SHALL PROVIDE SMOOTH SURFACE, FLUSH WITH EXISTING CONDITIONS, FREE OF ALL LOOSE OR DAMAGED MATERIAL AND PREPARED PRIOR TO RECEIVING NEW FINISHES. G. MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS THAT ARE CAPPED AND ABANDONED SHALL BE LOCATED BEHIND FINAL FINISH SYSTEMS OR 2 IN. (MIN) BELOW FINISH FLOOR. FILL HOLE WITH MATERIAL FLUSH AND SMOOTH TO MATCH ADJACENT SURFACE. H. FLUSH EXISTING WATER AND SANITARY LINES AFTER DEMOLITION WORK I. MATERIALS OF DEMOLITION SHALL BE DISPOSED OF LEGALLY OFF SITE UNLESS DIRECTED OTHERWISE BY OWNER. J. DEMOLITION CONTRACTOR IS TO VERIFY HIS WORK IN THE FIELD WITH THE DEMOLITION DRAWINGS. REPORT DISCREPANCIES TO THE ARCHITECT. K. CONTRACTOR SHALL NOTIFY OWNER IN ADVANCE WHEN OWNER REMOVED ITEMS NEED TO BE REMOVED. L. MAINTAIN ALL EGRESS EXITS AND LIFE SAFETY DEVICES WHILE PERFORMING DEMOLITION WORK. COORDINATE EXITING WITH OWNER AND LOCAL FIRE DEPARTMENT BEFORE COMMENCING WORK. M. COORDINATE WITH FIXTURE PLAN FOR REFRIGERATED CASES TO BE REMOVED. N. DEMOLITION WORK IN PREP AREAS TO OCCUR AT NIGHT. SEE KROGER REPRESENTATIVE FOR ADDITIONAL INFORMATION. O. CONTRACTOR TO PROVIDE TEMPORARY SUPPORT OF ALL ELECTRICAL, HVAC AND/OR LIGHTING DEVICES TO REMAIN AT CEILING DEMOLITION AREAS. P. THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN DUST PARTITION PROTECTION OF AREAS TO REMAIN OPERATIONAL OR REPLACEMENT OF HVAC FILTERS AT KROGER DISCRETION. Q. PROTECT WARRANTY MATERIALS TO REMAIN (ROOFING, MECHANICAL, TECHNOLOGY, ETC) R. REFER TO ASD-162A FOR TEMPORARY INTERIOR CONSTRUCTION PARTITION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CLEARANCES BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT ARCHITECT BEFORE PROCEEDING WITH WORK. VERIFICATION NOTE MATERIAL TAG E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 2 A1.1 DEMO CEILING PLAN REMOVE AND SALVAGE LIGHTING FROM AREA TO BECOME MEAT PREP REMOVE AND SALVAGE LIGHTING REMOVE EXISTING GYP. BD. CEILINGS RE: FLOOR PLANS FOR SOFFIT REWORK SALVAGE DEMO'D LIGHT FIXTURES. TYP. REMOVE EXISTING GRID, PANELS AND SUPPORTS FROM BREAKROOM. E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 4 A1.1 CEILING PLAN 119 ACCT. OPEN TO SALES 118 CUSTOMER SERVICE OPEN TO SALES 120 CHECKLANES X'-X" 100 SALES 12'-0" ETR 117 MEN 8'-0" ETR 116 WOMEN 8'-0" ETR 114 STORAGE 10'-6" ETR 112 DATA 9'-0" ETR 110 HALL "A" 9'-0" ETR 109 BREAK ROOM 9'-0" ETR 115 HALL "B" OPEN 113 OFFICE 9'-0" ETR 108 DAIRY COOLER - 105 BACK ROOM OPEN 107 ELECTRIC ROOM OPEN 106 DELI PREP - 103 SEAFOOD PREP - 101 HALL "C" OPEN 104 MEAT PREP 9'-0" 102 PRODUCE PREP 9'-0" ETR 111 JANITOR'S CLOSET 9'-0" ETR PROVIDE NEW CEILING PANELS THROUGHOUT NEW PRODUCE PREP NEW REFRIGERATION COIL, TYP. COORDINATE EXACT LOCATION WITH KROGER. REWORK LIGHTS IF NECESSARY, TYP. REFRIGERATION UNIT SUSPENDED FROM STRUCTURE ABOVE. CENTER IN JOIST SPACES ABOVE. RE: 46/A5.2 & 52/A5.2 AT EACH LOCATION. BOTTOM OF PLATFORM 12'-0" MIN. AFF 2' - 2 " 2' - 1 " 22 ' - 1 0 " 15 ' - 8 " ALING AREAS OF NEW GRID WITH EXISTING. MATCH EXISTING CEILING HEIGHTS PATCH AND REPAIR CEILING AS REQUIRED FOR INSTALLATION OF NEW WALL. PATCH AND REPAIR CEILING AS REQUIRED FOR INSTALLATION OF NEW WALL. PATCH AND REPAIR CEILING AS REQUIRED FOLLOWING REMOVAL OF WALL. CEILING NOTES ·REMOVE AND REPLACE CEILING TILES AS REQUIRED FOR WORK ABOVE CEILING (MEP, REFRIGERATION) AND FOR REWORK OF LIGHTS AND HVAC. FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : T u e s d a y , D e c e m b e r 0 9 , 2 0 1 4 1 0 : 1 1 : 2 0 A M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 DAVID R. JOHNSON LICENSE # 11100020 EXPIRES 12/31/2015 A1.1 KAP KAP GENERAL NOTES 1. WHERE TWO TILE THICKNESSES ADJOIN, PROVIDE TRANSITION, AS REQUIRED, TO PRODUCE FLUSH JOINT. SERVICE AREA WALL FINISHES 1. ALL FINISHES TO WRAP RETURNS AND TERMINATE ACCORDINGLY, UNLESS NOTED OTHERWISE. 2. ALL FINISHES SHALL TERMINATE 6" BEHIND LINE OF SIGHT AT PERMANENT FIXTURES OR CASEWORK. 3. ALL PAINT SHALL BE PROVIDED BY CONTRACTOR, UNLESS NOTED OTHERWISE. 4. VENTS, ELECTRICAL PANELS AND DOORS TO BE PAINTED SATIN FINISH ENAMEL. COLOR TO MATCH ADJACENT WALL FINISH, UNLESS NOTED OTHERWISE. 5. INSTALL OUTSIDE CORNER MOULDING AS NOTED ON PLAN AND AT OUTSIDE CORNERS WHERE NEW FINISHES OCCUR. REFER TO 20/i5.2. 6. PROVIDE CONTROL JOINTS IN GB AS REQUIRED 7. TOUCH UP PAINT ALL SURFACES 2 WEEKS PRIOR TO GRAND OPENING. FILL CRACKS AND PATCH SURFACES AS NECESSARY PRIOR TO PAINTING TRIM 1. REPAINT ALL EXISTING HOLLOW METAL DOORS AND FRAMES. SOFFITS 1. REFER TO A1.1 FOR SOFFIT LOCATIONS, DIMENSIONS. REFER TO DECOR DRAWINGS FOR FINISHES. BASE 1. ALL FINISHED WALLS TO RECIEVE WB-001 U.N.O. CARPET 1. INSTALL CARPET TILES AFTER FIXTURES ARE INSTALLED. 1. SEE FOR INTERIOR FINISH SCHEDULE, FINISH CODES, FINISH INFORMATION, AND FOR ADDITIONAL FINISH REQUIREMENTS THAT MAY NOT BE NOTED ON DRAWINGS. FINISH SCHEDULE GENERAL NOTES XX-XXX FIXTURING NOTES 1. RE: GISD-50 FOR INSTALLATION OF SALES FLOOR SHELVING WHERE A COLUMN INTERSECTS THE SHELVING. 2. REPLACE ALL TRIM ON EXISTING FIXTURES TO REMAIN WITH TRIM TO MATCH NEW FIXTURES. TRIM SUPPLIED BY KROGER, INSTALLED BY CONTRACTOR. 3. ALL EXISTING CHECKLANES AND U-SCANS TO REMAIN ARE TO BE RE-LAMINATED TO MATCH CURRENT DECOR SPEC. WALL BASE DETAILS NOTE: REFER TO ASD-51A AT EXPOSED INSULATED PANEL WALLS WHERE NO CURB OCCURS U.N.O. NOTE: ALL METAL STUD WALLS IN NON WASH DOWN AREAS TO RECEIVE BASE PER ASD-51D AT AREAS WITHOUT CONCRETE CURB, U.N.O. KEYNOTES 06-010 FRT PLYWOOD SHEATHING, 1/2" THICK U.N.O. 06-020 GALVANIZED WELDED WIRE FENCE. 08-024 ACCESS DOOR IN PARTITION ABOVE. COORDINATE LOCATION W/ KROGER ENGINEER. PROVIDE (1) PR HINGES, HASP AND PADLOCK. 09-001 FINISHED CEILING. RE: FINISH CEILING PLAN 09-011 METAL STUD FRAMING. RE: A1.1 FOR ADDITIONAL INFORMATION 09-014 DEFLECTION TRACK. SEE GENERAL NOTES FOR ADDITIONAL INFORMATION 09-030 GYPSUM WALL BOARD 11-010 PREFABRICATED INSULATED PANELS E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 A4.1 INTERIOR FINISH PLAN FLOOR: VINYL SHEET FLOORING. BASE: VINYL COVE BASE WALLS: FRP CL-002 CEILING: AC-003 FLOOR: SEAL EXISTING CONCRETE BASE: SEAL INSULATED PANELS AT FLOOR WALLS: EXPOSED INSULATED PANELS CEILING: EXPOSED INSULATED PANELS FLOOR: SEAL EXISTING CONCRETE BASE: SEAL INSULATED PANELS AT FLOOR WALLS: EXPOSED INSULATED PANELS CEILING: EXPOSED INSULATED PANELS FINISH NOTES ·PROVIDE NEW TRANSITION STRIPS AT REWORKED FLOORING AS REQUIRED. ·ALL HOLLOW METAL DOOR FRAMES EXCEPT RESTROOM AND EXTERIOR DOORS TO BE PAINTED PT-626 EXISTING FINISHES TO REMAIN IN BACKROOM FLOOR: EXISTING TO REMAIN, PATCH AS REQUIRED BASE: WB-001 WALLS: CL-001 TO 42", WC-005 ABOVE TO CEILING CEILING: EXISTING TO REMAIN FLOOR: EXISTING TO REMAIN, PATCH AS REQUIRED BASE: WB-001 WALLS: EXISTING TO REMAIN, PT-005 AT NEW WALL CEILING: EXISTING TO REMAIN FLOOR: EXISTING TO REMAIN, PATCH AS REQUIRED BASE: WB-001 WALLS: WC-005 CEILING: EXISTING TO REMAIN, PATCH AS REQUIRED 119 ACCT. 118 CUSTOMER SERVICE 120 CHECKLANES 100 SALES 117 MEN 116 WOMEN 114 STORAGE 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 101 HALL "C" 104 MEAT PREP 102 PRODUCE PREP 111 JANITOR'S CLOSET FLOOR: EXISTING TO REMAIN, PATCH AS REQUIRED BASE: WB-001 WALLS: EXISTING TO REMAIN, PT-005 AT NEW WALL CEILING: EXISTING TO REMAIN FLOOR: EXISTING TO REMAIN, PATCH AS REQUIRED BASE: WB-001 WALLS: PT-005 TO 10'-0" AFF CEILING: EXISTING TO REMAIN RESTROOMS EXISTING TO REMAIN VERTICAL SURFACES: PT-630 HORIZONTAL SURFACES OF SOFFITS: PT-601 TRANSITION PAINT AT COLUMN LINE TRANSITION PAINT AT OUTSIDE CORNER TRANSITION PAINT AT INSIDE CORNER OF SOFFIT AND OUTSIDE CORNER OF CHASE TRANSITION PAINT AT OUTSIDE CORNER/STEP IN SOFFIT TRANSITION PAINT AT END OF CURVE IN SOFFIT TRANSITION PAINT AT END OF CASE VERTICAL SURFACES: PT-625 HORIZONTAL SURFACES OF SOFFITS: PT-601 VERTICAL SURFACES: PT-622 HORIZONTAL SURFACES OF SOFFITS: PT-601 VERTICAL SURFACES: PT-626 HORIZONTAL SURFACES OF SOFFITS: PT-601 VERTICAL SURFACES: PT-625 HORIZONTAL SURFACES OF SOFFITS: PT-601 INSULATED PANEL TO BE LEFT EXPOSED GALVANIZED VERTICAL SURFACES: PT-625 VERTICAL SURFACES: PT-625 VERTICAL SURFACES: PT-623 HORIZONTAL SURFACES OF SOFFITS: PT-601 VERTICAL SURFACES: PT-623 SIDES AND BOTTOM OF SOFFITS INDICATED. PT-601 FIN FLR 6" 2 WALL TYPE 2 09-014 09-030 EA SIDE 09-011 09-001 EXTEND GYP. BD. TO DECK WHERE NO CEILING OCCURS TO D E C K OR 6 " A B O V E C L G 16'-0" U.N.O. 6" EXTEND GYP. BD. TO DECK WHERE NO CEILING OCCURS. 09-014 09-001 09-030 09-011 FIN FLR 06 - 0 1 0 09 - 0 3 0 3 WALL TYPE 5 5 WALL TYPE 25 11-010 FIN FLR 17 WALL TYPE 17 09-014 ALIGN FACE OF STUD WITH FACE OF COOLER/FREEZER 09-001 11-010 08-024 09-011 06-020 FIN FLR DOOR TYPES D7 D2 D9 DO O R NU M B E R TO WIDTH HEIGHT LA B E L TY P E FI N I S H HE A D JA M B SI L L TY P E FI N I S H GL A Z I N G LO U V E R LOCATION DOOR SIZE DETAIL DO O R NU M B E R REMARKS DOOR FRAME OPENING FINISH ABBREVIATIONS LABEL FRAME TYPE DOOR TYPE GLAZING LOUVER DOOR SCHEDULE NOTES AL ALUMINUM BR BRONZE CLT CLEAR TEMPERED HM HOLLOW METAL SC SOLID CORE P PRIMED WD WOOD PF PRE-FINISHED U UNFINISHED GAL GALVANIZED A UL 3 HR. B UL 1-1/2 HR. C UL 3/4 HR. D UL 1/3 HR. F1 ALUMINUM F2 HOLLOW METAL - 2" HEAD F3 OVERHEAD DOOR GUIDE F4 SIDE-STACKING GRILLE GUIDE F5 HOLLOW METAL - 4" HEAD F6 STEEL COL FOR CHAIN LINK FENCE F7 BENT PLATE F8 CHANNEL FRAME F9 POCKET DOOR WITH HEAVY DUTY SUSPENSION RAIL & HARDWARE F10 REINFORCED HOLLOW METAL DOOR FRAME LV1 14"x24" FROM D1 AUTOMATIC BIPARTING W/SIDELITE D2 HOLLOW METAL D3 STL INSUL. OVERHEAD SECTIONAL D4 SIDE-STACKING COILING GRILLE D5 INSULATED HOLLOW METAL D6 CHAIN LINK GATE D7 ABS PLASTIC - DOUBLE ACTING D8 FLAP DOORS - DOUBLE ACTING D9 PREFINISHED ALUMINUM DOOR W/ GLAZING D10 DUTCH DOOR D11 HALF-HEIGHT DOOR HARDWARE SET REFER TO SPECIFICATIONS FOR HARDWARE SET INFORMATION HA R D W A R E NO T E S 111 HALL 'A' JANITORS CLOSET 3'-0" 6'-8" - F2 P H16 J16 - D2 P -- 2 - -111 109 SALES BREAK ROOM 3'-0" 6'-8" - F2 P H16 J16 - D2 P G2 - 4 - -109 G1 FULL- TINTED TEMPERED G2 HALF GLASS- CLEAR TEMPERED G3 10" x 10" - MIRROR TEMPERED G4 CLEAR TEMPERED NOTE: FOR ALL LOCKING MECHANISMS, PROVIDE FOR BEST HARDWARE. 1. DRILL AND TAP TOP OF JAMB GUARD AND FASTEN BOTTOM PIN ASSEMBLY WITH STUD BOLTS 2. THESE DOORS SUPPLIED W/ HINGES. RE SPECS. INDIVIDUAL DOOR LEAVES ARE OPERABLE AS SWING DOORS IN THE EVENT OF AN EMERGENCY 3. DOOR LEAF SIZE OF 42", EACH, YIELDS A NET CLEAR OPENING OF 72" 4. DOOR LEAF SIZE OF 54", EACH, YIELDS A NET CLEAR OPENING OF 96" 5. NO ACCESS REQUIRED FROM EXTERIOR SIDE OF DOOR. 6. PROVIDE TACTILE EXIT SIGNAGE 5'-0" A.F.F. ON THE ADJACENT WALL ON THE LATCH SIDE OF DOOR. 7. PROVIDE ADA SIGNAGE. RE: A4.1 FOR ADDITIONAL INFORMATION 115 HALL 'B' EXTERIOR 3'-4" V.I.F. 7'-0" V.I.F. - F1 P - - - D9 P G4 - 8B 6 115 102 HALL 'C' PRODUCE PREP 3'-0" V.I.F. 6'-8" V.I.F. - F10 PF - - - D7 PF - - 17 1, 2 NEW DOOR IN EXISTING FRAME 102 103 HALL 'C' SEAFOOD PREP 3'-0" 7'-0" - F10 PF ASD-55 ASD-55 - D7 PF - - 17 1, 2 FRAME PROVIDED BY KROGER AND INSTALLED BY CONTRACTOR 103 104 HALL 'C' MEAT PREP 3'-0" 7'-0" - F10 PF ASD-56A ASD-56A -D7 PF - - 17 1, 2 FRAME PROVIDED AND INSTALLED BY CONTRACTOR 104 106 BACKROOM DELI PREP 3'-0" 7'-0" - F10 PF ASD-55 ASD-55 - D7 PF - - 17 1, 2 FRAME PROVIDED BY KROGER AND INSTALLED BY CONTRACTOR 106 JAMB COL: 2- STUDS ATTACHED W/ 2-STUD TRACKS SEALANT BOTH SIDES COORDINATE THROAT DIMENSION WITH WALL TYPES HEAD/JAMB HOLLOW MTL DOOR HOLLOW MTL FRAME PARTITION CONSTRUCTION RE: WALL TYPES J16 A6.1 H16 A6.1 114 SALES STORAGE 3'-0" 6'-8" - F2 P H16 J16 - D2 P - - 2 - -114 A4.1 FINISH PLAN, DOOR SCHEDULE + DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : T u e s d a y , D e c e m b e r 0 9 , 2 0 1 4 1 0 : 5 2 : 1 6 A M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 DAVID R. JOHNSON LICENSE # 11100020 EXPIRES 12/31/2015 KAP KAP 4x4 FRAMING CLIP. 16" LONG, MIN. 3 FLANGES. REFER TO PLAN FIN. CLG. SCALE: 1 2"=1'-0" 23 A5.2 TYPICAL DROP SOFFIT PERPENDICULAR TO JOISTS REFER TO PLAN FIN. CLG. EXTEND GWB TO DECK AT OPEN CEILING 3-5/8" METAL STUDS @ 16" O.C. w/ STUD TRACK TOP & BOT. (TO ROOF DECK) GWB GWB 6" 3-5/8" X 18 GA CONTINUOUS METAL STUDS 1-1/2" COLD ROLLED CHANNEL CONTINUOUS 3 5/8" MET STUD BRACING @ 8'-0" O.C. @ JOIST PANEL POINTS. SEMI-GLOSS @ PREP AREA SEMI-GLOSS @ PREP AREA RE: INTERIOR ELEVATIONS FOR EXPOSED WALL FINISHES 6" DEEP LEG TRACK 18" GA TRACK (2" LEG) TOP AND BOTTOM CONT. BRIDGING NEAR MIDSPAN. (4) #10 TEK SCREWS @ 4'-0" O.C.. MAX (2) #10 TEK SCREWS EA. STUD. SCALE: 1 2"=1'-0" 24 A5.2 TYPICAL DROP SOFFIT PARALLEL TO JOISTS REFER TO PLAN FIN. CLG. 3-5/8" METAL STUDS @ 16" O.C. w/ STUD TRACK TOP & BOT. (TO ROOF DECK) 6" 1-1/2" COLD ROLLED CHANNEL CONTINUOUS CONT. BRIDGEING NEAR MIDSPAN. GWB SEMI-GLOSS @ PREP AREA SEMI-GLOSS @ PREP AREA EXTEND GWB TO DECK AT OPEN CEILING GWB 6" RE: INTERIOR ELEVATIONS FOR EXPOSED WALL FINISHES REFER TO PLAN FIN. CLG. 4x4 FRAMING CLIP. 16" LONG, MIN. 3 FLANGES. UNISTRUT P1000 @ 4'-0" O.C. DEEP LEG TRACK 3 5/8" MET STUD BRACING @ 8'-0" O.C. @ JOIST PANEL POINTS. 18" GA TRACK (2" LEG) TOP AND BOTTOM (4) #10 TEK SCREWS @ 4'-0" O.C.. MAX (2) #10 TEK SCREWS EA. STUD. 3 5/8" X 18 GA. CONTINUOUS METAL STUD.. BOLT THRU BOTTOM CHORD ANGLES UNISTRUT @ JOIST PANEL POINT STUD CLIP W/(4) #10 TEK SCREWS BOTTOM OF CHORD JOIST 3 5/8" STUD JOIST WEB MEMBER A A SCALE: 1 2"=1'-0" 46 A5.2 EQUIPMENT SUPPORT SUSPENDED FROM STRUCTURE EQUIPMENT MAX WT 655 lbs 1/2" THREADED ROD SUPPORT HANGER. ATTACH TO STRUCTURE ABOVE. IF NOT AT JOIST PANEL POINT SEE TYP. DETAIL FOR JOIST REINFORCING ON STRUCTURAL DRAWINGS ROOF JOIST "UNI-STRUT" P5000T FRAMING SYSTEM PERPINDUCULAR TO JOISTS 1/2" THREADED ROD SUPPORT HANGER. ATTACH TO STRUCTURE ABOVE. TYP. 6'-0" MAX DOUBLE NUT 3"x3"x 1 4" PLATE WASHER DOUBLE ANGLE BOTTOM CORD OF EXIST JOIST 3 4" FRT PLYWD. ATTACH TO UNISTRUT W/ #10 SELF TAPPING SCREWS @ 12" O.C. ALL SIDES TOP OF COOLER/FREEZER "UNI-STRUT" P5000T FRAMING MEMBERS/ ALIGN WITH SUPPORT LEGS OR UNIT CURB "UNI-STRUT" P5000T FRAMING MEMBERS "UNI-STRUT" P1000T FRAMING MEMBERS. ALIGN WITH HANGER RODS 1/2" THREADED ROD SUPPORT HANGER AT EA CORNER LINE OF PLYWD PLATFORM "UNI-STRUT" P5000T FRAMING "UNI-STRUT" P1065 CONNECTOR "UNI-STRUT" P100T FRAMING "UNI-STRUT" P5000T FRAMING "UNI-STRUT" P1000T FRAMING "UNI-STRUT" P1065 CONNECTOR 3 4" FRT PLYWD. NOTCH AT ROD HANGER COORDINATE ROOF FRAMING WITH FINAL SELECTION OF ROOF SUPPORTED MECHANICAL EQUIPMENT AND ASSOCIATED OPENINGS. ITEMS TO BE COORDINATED INCLUDE SIZE, LOCATION, TOTAL WIEGHT, WEIGHT DISTRIBUTION, AND SUPPORT FRAME REQUIREMENTS. MECHANICAL UNIT L6x4x5/16 (LLV) BELOW MECHANICAL UNIT CURB IF DECK CORRUGATION DOES NOT BEAR ON ANGLE, SOLID BLOCKING/ SHIMS ALONG EDGE OF OPENING IS REQUIRED. L1 1/2x1 1/2x3/16 WEB STIFFENER SEE TYPICAL SUPPORT OF CONCENTRATED LOADS NOT AT JOIST PANEL POINTS 3/16 3/16 1 1/2 COPE ANGLE VERTICAL LEG ROOF DECK OPENING AS REQUIRED, SEE MECH DWGS TOP CHORD PANEL POINT L1 1/2x1 1/2x3/16 EA SIDE AT CONCENTRATED LOADS CONCENTRATED LOAD TOP CHORD JOIST WEB CONCENTRATED LOAD 3/16 TYP BOTTOM CHORD PANEL POINT N.T.S. N.T.S. SCALE: N.T.S. 52 A5.2 DETAILS RTU STRUCTURAL SUPPORT installation steps: NOTES: NOTES: A5.2 FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : T u e s d a y , D e c e m b e r 0 9 , 2 0 1 4 1 0 : 1 1 : 4 0 A M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 DAVID R. JOHNSON LICENSE # 11100020 EXPIRES 12/31/2015 KAP KAP FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 6 : 0 1 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 P0.1 PLUMBING COVER SHEET ABBREVIATIONS AAV AIR ADMITTANCE VALVE ID INDIRECT WASTE AFF ABOVE FINISHED FLOOR IE INVERT ELEVATION AFG ABOVE FINISHED GRADE INT INTERCEPTOR BFF BELOW FINISHED FLOOR LAV LAVATORY BFG BELOW FINISHED GRADE MC MECHANICAL CONTRACTOR BFP BACK FLOW PREVENTER MPG MEDIUM PRESSURE GAS CD CONDENSATE DRAIN MR MOP RECEPTOR CFH CUBIC FEET PER HOUR NFPA NATIONAL FIRE PROTECTION ASSOCIATION CO CLEAN OUT NTS NOT TO SCALE CWV COMBINATION WASTE & VENT OVD OVERFLOW DRAIN DCW DOMESTIC COLD WATER ODL OVERFLOW DRAIN LEADER DHW DOMESTIC HOT WATER PC PLUMBING CONTRACTOR DHWR DOMESTIC HOT WATER RETURN PRO PRODUCE DS DOWNSPOUT PRV PRESSURE REDUCING VALVE EC ELECTRICAL CONTRACTOR RD ROOF DRAIN ECO EXPOSED CLEANOUT RDL ROOF DRAIN LEADER EW EYEWASH SAN SANITARY EWC ELECTRIC WATER COOLER SD STORM DRAIN EWH ELECTRIC WATER HEATER SF SEAFOOD EXP EXPANSION TANK SK SINK FCO FLOOR CLEAN OUT SP SUMP PUMP FD FLOOR DRAIN ST STORM PIPING FDC FIRE DEPARTMENT CONNECTION TD TRENCH DRAIN FPWH FREEZE PROOF WALL HYDRANT TMV THERMOSTATIC MIXING VALVE FS FLOOR SINK TP TRAP PRIMER FSR FIRE SPRINKLER RISER TYP TYPICAL G GAS UON UNLESS OTHERWISE NOTED GCO GRADE CLEANOUT UR URINAL GW GREASE WASTE V VENT GWH GAS WATER HEATER VTR VENT THRU ROOF HB HOSE BIBB WC WATER CLOSET HD HUB DRAIN WCO WALL CLEAN OUT HWHB HOT WATER HOSE BIBB WH WALL HYDRANT or WATER HEATER WHA WATER HAMMER ARRESTOR A. THE WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH BASE BUILDING SPECIFICATION AND WITH THE LATEST EDITION OF THE PREVAILING STATE PLUMBING AND BUILDING CODES AND ALL LOCAL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE STRINGENT STANDARD SHALL APPLY. B. ALL SANITARY WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC OR HUBLESS CAST IRON AND SLOPED A MINIMUM OF 1/8" PER FOOT WHERE INSTALLED IN THE HORIZONTAL POSITION. MATERIAL SHALL COMPLY WITH CODE REQUIREMENTS. C. DOMESTIC WATER PIPING BELOW GRADE OR SLAB SHALL BE TYPE 'K' COPPER, WATER PIPING ABOVE SLAB SHALL BE TYPE 'L'. INSULATE WATER PIPING WITH 1/2" ARMAFLEX II OR RUBATEX R-180-FS OR EQUAL. D. ALL PLUMBING FIXTURES SHALL BE SUPPLIED WITH INDIVIDUAL WATER STOPS AND CODE APPROVED TRAPS. EXPOSED PIPING SHALL BE CHROME PLATED WITH ESCUTCHEONS AT WALL PENETRATIONS. E. NO PIPING SHALL PASS DIRECTLY OVER ELECTRICAL POWER DISTRIBUTION CABINETS OR PANELS. CONTRACTOR SHALL COORDINATE PANEL LOCATIONS PRIOR TO PIPING INSTALLATION. F. ALL FLOOR DRAIN TRAPS SHALL BE PROVIDED WITH TRAP PRIMERS PER LOCAL CODES HAVING JURISDICTION. G. ALL PLUMBING WORK SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO PROCEEDING WITH INSTALLATION. H. ALL DOMESTIC WATER BRANCH LINES SHALL HAVE BALL TYPE ISOLATION VALVES. I. PROVIDE WATER HAMMER ARRESTORS (WHA) AT ALL WATER PIPE DROPS TO FIXTURES WITH QUICK CLOSING VALVES AND ON SYSTEMS WITH HIGHER THAN NORMAL PRESSURE WHERE WATER HAMMER MAY BE AN ISSUE. J. INSTALL ALL FLOOR CLEANOUTS TO CLEAR EQUIPMENT AND PROVIDE REQUIRED ACCESSIBILITY. K. VERIFY INVERT ELEVATIONS AND EXACT LOCATIONS OF ALL OUTSIDE UTILITIES PRIOR TO INSTALLING ANY UNDERGROUND PIPING. COORDINATE WITH SITE UTILITY PLAN AND CIVIL ENGINEER. L. PLUMBING CONTRACTOR SHALL COORDINATE THE LOCATION OF VENTS THROUGH ROOF WITH ROOFTOP UNIT AIR INTAKE LOCATIONS. VENTS MUST BE A MINIMUM 10'-0" FROM AIR INTAKES, PER CODE. M. DO NOT ATTACH SCREWS, NAILS, HANGERS OR FASTENERS OF ANY TYPE TO ROOF DECK. N. ALL PIPE DROPS IN SALES AREA FROM ROOF TO LOW WALLS OR EQUIPMENT SHALL BE COORDINATED AND GROUPED TOGETHER WITH OTHER MECHANICAL PIPES. O. NO SURFACE MOUNTED WATER OR VENT LINES PERMITTED EXPOSED IN PREP ROOMS. P. ALL CASE DRAINS MUST BE ACCESSIBLE AND SCREENED TO PREVENT RODENT ENTRY. Q. ALL PLUMBING FIXTURES OR EQUIPMENT DRAINING INTO THE SANITARY SEWER SYSTEM VIA AN INDIRECT WASTE CONNECTION SHALL HAVE A 1" AIR GAP AS REQUIRED BY UNIFORM PLUMBING CODE. R. PLUMBING CONTRACTOR SHALL INSTALL CHECK VALVES IN HOT & COLD WATER SUPPLY LINES TO OWNER FURNISHED FOOD PREP AND UTENSIL STAINLESS STEEL SINKS IN PREP AREAS. S. ALL GENERAL PURPOSE WATER HEATERS SHALL BE SET AT 110° F. SET WATER HEATER SERVING UTENSIL WASHER TO 140° MINIMUM AND PROVIDE THERMOSTATIC MIXING VALVE FOR SANITIZING PURPOSES. T. PROVIDE CHECK VALVE IN WATER LINES FOR ALL 3 COMPARTMENT SINKS AND MOP RECEPTORS TO PROHIBIT BACKFLOW. U. ALL ISOLATION VALVES SHOULD BE INSTALLED AT 10'-6" WHERE POSSIBLE. GENERAL NOTES PLUMBING SYMBOLS EXISTING TO REMAIN EXISTING TO BE REMOVED NEW WORK SANITARY WASTE VENT PIPING DOMESTIC COLD WATER (DCW) DOMESTIC HOT WATER (DHW) DOMESTIC HOT WATER RETURN (DHWR) NATURAL GAS CONDENSATE DRAIN BALL VALVE GATE VALVE CHECK VALVE BALANCING VALVE PRESSURE REDUCING VALVE GAS COCK FLOOR DRAIN HUB DRAIN VENT THRU ROOF WALL CLEANOUT NEW WORK POINT CONNECTION GREASE WASTE COMBINATION WASTE & VENT (HUB DRAINS) SOFTENED WATER REVERSE OSMOSIS WATER STORM DRAIN OVERFLOW DRAIN BUTTERFLY VALVE FLOOR SINK (ROUND) FLOOR SINK (SQUARE) INDIRECT WASTE PRESSURE GAUGE THERMOSTATIC MIXING VALVE FLOOR OR GRADE CLEANOUT COMBINATION WASTE & VENT (EXISTING SYSTEMS) CAPPED SANITARY DRAIN PIPING BELOW SLAB WS CB E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 PD1.1 DEMOLITION PLAN PLUMBING WASTE AND VENT E- 1 12" V E- 4" SAN E- 4 " S A N E- 4 " S A N E- 3" SAN E- 1 12" V E- 1 12" V EXISTING FCO (TYP) 2 1 (TYP) 2 (TYP) (TYP) EXISTING VTR 3 EXISTING GCO EXISTING VTR PLUMBING WASTE AND VENT DEMOLITION PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 7 : 2 8 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES A. CONTRACTOR SHALL REMOVE ALL EXISTING PLUMBING FIXTURES, EQUIPMENT AND ASSOCIATED PIPING, HANGERS AND ACCESSORIES INCLUDING VALVES, ETC. REMOVE PIPING BACK TO MAINS AND CAP SERVICE UTILITIES AT FLOOR OR WALL AS REQUIRED, INCLUDING SANITARY WASTE, WATER AND GAS PIPING FOR FUTURE EXTENSION UNDER TENANT FINISH PORTION OF PROJECT. B. NOTIFY OWNER IN WRITING AND FIELD VERIFY EXISTING CONDITIONS PRIOR TO PERFORMING ANY SAWCUTTING, TRENCHING, CORING OR ANY STRUCTURAL MODIFICATIONS DUE TO DEMOLITION. ENSURE THAT NO ADVERSE EFFECT TO THE BUILDINGS INTEGRITY WILL OCCUR. C. ANY EXISTING CONDITION DISCOVERED DURING THE DEMOLITION PHASE WHICH, BY GENERALLY ACCEPTED CONSTRUCTION PRACTICES, SHOULD BE REMEDIED SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND/OR ENGINEER IMMEDIATELY. D. PROVIDE PROTECTION TO THE EXISTING FACILITY FROM DAMAGE OF ANY KIND DURING ALL PHASES OF THE PROJECT. E. OBTAIN WRITTEN APPROVAL FROM THE ARCHITECT AND/OR ENGINEER BEFORE REUSING ANY EXISTING EQUIPMENT, COMPONENTS OR OPENINGS. WS CB EXISTING SYSTEMS / EQUIPMENT / LOCATIONS / CIRCUITING INFORMATION ON THIS DRAWING ARE FROM OWNERS AS-BUILT RECORD DOCUMENTS, AND ARE FOR REFERENCE USE. REFER TO F1 FIXTURE PLAN FOR ADDITIONAL STORE FIXTURE REQUIREMENTS. CONTRACTOR SHALL FIELD VERIFY ALL NECESSARY CIRCUITS FOR REUSE, PRIOR TO DEMOLITION. INFORMATION FROM OWNERS AS-BUILT DOCUMENTS ARE BELIEVED TO BE ACCURATE BUT CONTRACTOR MUST FIELD VERIFY ACCURACY PRIOR TO SUBMITTING BID. KEY NOTES 1. EXISTING PLUMBING FIXTURE TO REMAIN. 2. EXISTING PLUMBING FIXTURE TO BE REMOVED INCLUDING ALL PIPING, FITTINGS, HANGERS AND ACCESSORIES. CAP PIPING BELOW SLAB OR ABOVE CEILING.. 3. EXISTING FLOOR DRAIN TO BE REMOVED AND CAPPED OFF BELOW SLAB. REFER TO DETAIL PD-B/P5.1. E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 P1.2 DEMOLITION PLAN PLUMBING DOMESTIC WATER AND GAS EXISTING WATER SERVICE W/BFP 1 (TYP) EXISTING WATER HEATER ABOVE TO REMAIN 2 (TYP) 2 (TYP) PD1.2 PLUMBING WATER AND GAS DEMOLITION PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 2 : 3 6 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES A. CONTRACTOR SHALL REMOVE ALL EXISTING PLUMBING FIXTURES, EQUIPMENT AND ASSOCIATED PIPING, HANGERS AND ACCESSORIES INCLUDING VALVES, ETC. REMOVE PIPING BACK TO MAINS AND CAP SERVICE UTILITIES AT FLOOR OR WALL AS REQUIRED, INCLUDING SANITARY WASTE, WATER AND GAS PIPING FOR FUTURE EXTENSION UNDER TENANT FINISH PORTION OF PROJECT. B. NOTIFY OWNER IN WRITING AND FIELD VERIFY EXISTING CONDITIONS PRIOR TO PERFORMING ANY SAWCUTTING, TRENCHING, CORING OR ANY STRUCTURAL MODIFICATIONS DUE TO DEMOLITION. ENSURE THAT NO ADVERSE EFFECT TO THE BUILDINGS INTEGRITY WILL OCCUR. C. ANY EXISTING CONDITION DISCOVERED DURING THE DEMOLITION PHASE WHICH, BY GENERALLY ACCEPTED CONSTRUCTION PRACTICES, SHOULD BE REMEDIED SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND/OR ENGINEER IMMEDIATELY. D. PROVIDE PROTECTION TO THE EXISTING FACILITY FROM DAMAGE OF ANY KIND DURING ALL PHASES OF THE PROJECT. E. OBTAIN WRITTEN APPROVAL FROM THE ARCHITECT AND/OR ENGINEER BEFORE REUSING ANY EXISTING EQUIPMENT, COMPONENTS OR OPENINGS. WS CB EXISTING SYSTEMS / EQUIPMENT / LOCATIONS / CIRCUITING INFORMATION ON THIS DRAWING ARE FROM OWNERS AS-BUILT RECORD DOCUMENTS, AND ARE FOR REFERENCE USE. REFER TO F1 FIXTURE PLAN FOR ADDITIONAL STORE FIXTURE REQUIREMENTS. CONTRACTOR SHALL FIELD VERIFY ALL NECESSARY CIRCUITS FOR REUSE, PRIOR TO DEMOLITION. INFORMATION FROM OWNERS AS-BUILT DOCUMENTS ARE BELIEVED TO BE ACCURATE BUT CONTRACTOR MUST FIELD VERIFY ACCURACY PRIOR TO SUBMITTING BID. 1. EXISTING PLUMBING FIXTURE TO REMAIN. 2. EXISTING PLUMBING FIXTURE TO BE REMOVED. CONTRACTOR SHALL REMOVE FIXTURE, HANGERS, FITTINGS, PIPING AND ACCESSORIES AS REQUIRED. SEE NEW WORK PLAN FOR FIXTURES BEING INSTALLED BACK IN THIS PLACE (WHERE APPLICABLE) KEY NOTES E 1 2 3 4 D C B A E- 1 12" V E- 4" SAN E- 4 " S A N E- 4 " S A N E- 3" SAN E- 1 12" V E- 1 12" V SCALE: 3/32"=1'-0" 1 P1.1 PLUMBING WASTE AND VENT PLAN PL3-20 PLHSW PL3-20 PLHSW PL1BR VAC VAC EXISTING VTR 1 (TYP) 2 VACUUM SYSTEM 4 5 5 6 6 6 6 6 6 6 PL3C-18NS XXX CHECKLANES 100 SALES 117 MEN 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 101 MEAT PREP 102 PRODUCE PREP 7 7 7 8FS-1 2" VA C VA C VA C 3" 2" 3" VAC DISCHARGE 2" TIE NEW 1 12" VENT INTO EXISTING 4" 112" RISER (TYP) V ECO (TYP) MOP SINK ICE MACHINE PLHSW PL1SLND PL1PC PL3-20 PLHSW ROUTE PIPING AS HIGH AS POSSIBLE 114 STORAGE 104 HALL 'C' 111 JANITOR'S CLOSET 119 ACCT. 118 CUSTOMER SERVICE 116 WOMEN 9 10 P1.1 PLUMBING WASTE AND VENT PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : T u e s d a y , D e c e m b e r 0 9 , 2 0 1 4 9 : 1 1 : 3 9 A M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES A. REFER TO SHEET P0.1 FOR LEGENDS, ABBREVIATIONS AND GENERAL NOTES. WS CB KEY NOTES 1. EXISTING PLUMBING FIXTURE TO REMAIN. 2. NEW PLUMBING FIXTURE TO BE INSTALLED. TIE INTO SANITARY WASTE AND VENT PIPING AS INDICATED. PROVIDE ALL NECESSARY FITTINGS AND ACCESSORIES. 3. PROVIDE NEW HUB DRAIN AND TIE BACK INTO EXISTING SANITARY BELOW SLAB AS INDICATED. 4. VACUUM SYSTEM EQUAL TO ACORNVAC DUPLEX 60 GALLON, 3 HP LIQUID RING VAC CENTER STACK MOUNTED WITH 24" DIAMETER WASTE STORAGE TANKS WITH SE CONTROL PANEL. CONTRACTOR SHALL DISASSEMBLE THE SYSTEM AS REQUIRED TO FIT INTO SPACE AND PROVIDE CLEARANCE FOR MAINTENANCE. COORDINATE WITH EQUIPMENT SUPPLIER. 5. PROVIDE 2" SWING CHECK AND SHUT-OFF VALVE AT EACH RISER. 6. PROVIDE ACCUMULATOR FOR EACH FIXTURE: HAND SINK = 0.5 GPM, ONE AND THREE COMP = 10 GPM, REFRIGERATED CASE = 1.0 GPM 7. PROVIDE LOW PROFILE GREASE TRAP FOR ONE AND THREE COMPARTMENT SINKS PER LOCAL CODE HAVING JURISDICTION. ONE COMP SINK = 30 LB GREASE, 15 GPM FLOW THREE COMP SINK = 50 LB GREASE, 25 GPM FLOW TRAPS WILL NEED TO BE VENTED PER MANUFACTURER'S RECOMMENDATIONS. 8. FLOOR SINK FS-1 EQUAL TO JAY R SMITH MODEL 3200, 18" SQUARE x 12" DEEP, 4" SANITARY - PROVIDE 1" AIR GAP. 9. ROUTE 3 4" CONDENSATE DRAIN FROM COOLERS TO MOP SINK. 10. MOP SINK FURNISHED WITH ACORNVAC EQUIPMENT, INSTALLED BY PLUMBING CONTRACTOR. NOTE: SUCCESSFUL CONTRACTOR SHALL CONTACT ACORNVAC AND RECEIVE ON-LINE TRAINING TO ENSURE PROPER INSTALLATION OF SYSTEMS, PIPING AND EQUIPMENT. E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 P1.2 PLUMBING DOMESTIC WATER AND GAS PLAN PL1BR EXISTING 1" WATER SERVICE WITH BFP GWH-1 80 GALLONS PL3-20 PLHSW 1 (TYP) 2 3 PL3-20 PLHSW PL3-20 PLHSW HB-2 1" 3 4" 12" DCW AND DHW DOWN TO FIXTURE (TYPICAL) 3 4" 3 4" DCW AND DHW TIE INTO EXISTING 12" DHW TIE INTO EXISTING 12" DCW AND DHW EXP-1 PL3C-18NS 4 12" DCW AND DHW DN TO FIXTURE (TYP) PL3-20 2 PLHSW PL1M PL1SLND PL1PC G G G NEW GAS METER PER UTILITY CO 1" GAS MOUNTED ON WALL 10'-0" AFF 5 5 52" GAS TO GENERATOR 2" GAS MOUNTED ON WALL 10'-0" AFF 1" GAS TO WATER HEATER EXISTING GAS TO ROOFTOP UNITS ICE MACHINE 6 HB-2 HB-2 HB-2 WATER HEATER ABOVE TO REMAIN XXX CHECKLANES 100 SALES 117 MEN 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 101 MEAT PREP 102 PRODUCE PREP 114 STORAGE 104 HALL 'C' 111 JANITOR'S CLOSET 119 ACCT. 118 CUSTOMER SERVICE 116 WOMEN P1.2 PLUMBING DOMESTIC WATER AND GAS PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 6 : 3 3 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES A. REFER TO SHEET P0.1 FOR LEGENDS, ABBREVIATIONS AND GENERAL NOTES. WS CB KEY NOTES 1. EXISTING PLUMBING FIXTURE TO REMAIN. 2. NEW PLUMBING FIXTURE TO BE INSTALLED. TIE INTO DOMESTIC WATER PIPING AS INDICATED. PROVIDE ALL NECESSARY VALVES, FITTINGS AND ACCESSORIES. 3. PROVIDE WATER HEATER INSTALLED ABOVE COOLER. PROVIDE GAS CONNECTION TO EQUIPMENT INCLUDING GAS COCK, UNION, PRV (WHERE APPLICABLE), FULL SIZE DIRT LEG AND FLEXIBLE CONNECTOR. COORDINATE WITH EQUIPMENT PROVIDER. PROVIDE DRAIN PAN AND ROUTE DISCHARGE TO COLLECTOR FOR ICE MACHINE BELOW. 4. PROVIDE 12" DCW FOR ACORNVAC MAKE-UP WATER WITH SEDIMENT FILTER, BACKFLOW PREVENTER AND VALVES. 5. PROVIDE NEW GAS CONNECTION AT METER AND EXTEND GAS PIPING ON ROOF TO NEW EQUIPMENT AS INDICATED. PROVIDE GAS COCK, UNION, PRV (2PSI - 11"-14" W.C.) AND FLEXIBLE CONNECTOR. 6. PROVIDE VALVE AND IN-LINE WATER FILTER FOR ICE MACHINE. V - 4 AJ P - 0 0 5 2 8 - 0 0 4 AL L D I M E N S I O N S I N I N C H E S Co p y r i g h t - " T h i s d r a w i n g a n d t h e in f o r m a t i o n c o n t a i n e d h e r e i n i s a n d sh a l l r e m a i n t h e p r o p e r t y o f AC O R N V A C , I N C . I t m u s t n o t be u s e d o r r e p r o d u c e d f o r a n y o t h e r pu r p o s e o t h e r t h a n t h a t s t a t e d i n t h e do c u m e n t s f o r w h i c h i t w a s p r o d u c e d . Un a u t h o r i z e d u s e i n a n y f o r m wh a t s o e v e r i s s t r i c t l y p r o h i b i t e d ©" VA C U U M P L U M B I N G S Y S T E M KR O G E R J 9 5 9 - C A R M E L , I N IN S T A L L A T I O N D E T A I L S Ac o r n V a c , I n c . (8 0 0 ) 5 9 1 - 9 9 2 0 - F A X ( 9 0 9 ) 9 0 2 - 5 0 4 1 VA C U U M P L U M B I N G S Y S T E M 13 8 1 8 O a k s A v e n u e C h i n o , C A 9 1 7 1 0 U . S . A . JM T 21 N O V E M B E R , 2 0 1 4 3/ 1 6 " = 1 2 " ( E ) P5.5 PLUMBING DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 7 : 0 7 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 WS CB V - 3 AJ P - 0 0 5 2 8 - 0 0 3 AL L D I M E N S I O N S I N I N C H E S Co p y r i g h t - " T h i s d r a w i n g a n d t h e in f o r m a t i o n c o n t a i n e d h e r e i n i s a n d sh a l l r e m a i n t h e p r o p e r t y o f AC O R N V A C , I N C . I t m u s t n o t be u s e d o r r e p r o d u c e d f o r a n y o t h e r pu r p o s e o t h e r t h a n t h a t s t a t e d i n t h e do c u m e n t s f o r w h i c h i t w a s p r o d u c e d . Un a u t h o r i z e d u s e i n a n y f o r m wh a t s o e v e r i s s t r i c t l y p r o h i b i t e d ©" VA C U U M P L U M B I N G S Y S T E M KR O G E R J 9 5 9 - C A R M E L , I N ZO N E C O N T R O L P A N E L D E T A I L S Ac o r n V a c , I n c . (8 0 0 ) 5 9 1 - 9 9 2 0 - F A X ( 9 0 9 ) 9 0 2 - 5 0 4 1 VA C U U M P L U M B I N G S Y S T E M 13 8 1 8 O a k s A v e n u e C h i n o , C A 9 1 7 1 0 U . S . A . JM T 21 N O V E M B E R , 2 0 1 4 9/ 1 6 " = 1 2 " ( E ) P5.4 PLUMBING DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 7 : 0 1 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 WS CB V - 2 AJ P - 0 0 5 2 8 - 0 0 2 AL L D I M E N S I O N S I N I N C H E S Co p y r i g h t - " T h i s d r a w i n g a n d t h e in f o r m a t i o n c o n t a i n e d h e r e i n i s a n d sh a l l r e m a i n t h e p r o p e r t y o f AC O R N V A C , I N C . I t m u s t n o t be u s e d o r r e p r o d u c e d f o r a n y o t h e r pu r p o s e o t h e r t h a n t h a t s t a t e d i n t h e do c u m e n t s f o r w h i c h i t w a s p r o d u c e d . Un a u t h o r i z e d u s e i n a n y f o r m wh a t s o e v e r i s s t r i c t l y p r o h i b i t e d ©" VA C U U M P L U M B I N G S Y S T E M KR O G E R J 9 5 9 - C A R M E L , I N ZO N E C O N T R O L P A N E L D E T A I L S Ac o r n V a c , I n c . (8 0 0 ) 5 9 1 - 9 9 2 0 - F A X ( 9 0 9 ) 9 0 2 - 5 0 4 1 VA C U U M P L U M B I N G S Y S T E M 13 8 1 8 O a k s A v e n u e C h i n o , C A 9 1 7 1 0 U . S . A . JM T 21 N O V E M B E R , 2 0 1 4 9/ 1 6 " = 1 2 " ( E ) P5.3 PLUMBING DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 6 : 5 6 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 WS CB V - 1 AJ P - 0 0 5 2 8 - 0 0 1 AL L D I M E N S I O N S I N I N C H E S Co p y r i g h t - " T h i s d r a w i n g a n d t h e in f o r m a t i o n c o n t a i n e d h e r e i n i s a n d sh a l l r e m a i n t h e p r o p e r t y o f AC O R N V A C , I N C . I t m u s t n o t be u s e d o r r e p r o d u c e d f o r a n y o t h e r pu r p o s e o t h e r t h a n t h a t s t a t e d i n t h e do c u m e n t s f o r w h i c h i t w a s p r o d u c e d . Un a u t h o r i z e d u s e i n a n y f o r m wh a t s o e v e r i s s t r i c t l y p r o h i b i t e d ©" VA C U U M P L U M B I N G S Y S T E M KR O G E R J 9 5 9 - C A R M E L , I N VA C U U M C E N T E R D E T A I L S Ac o r n V a c , I n c . (8 0 0 ) 5 9 1 - 9 9 2 0 - F A X ( 9 0 9 ) 9 0 2 - 5 0 4 1 VA C U U M P L U M B I N G S Y S T E M 13 8 1 8 O a k s A v e n u e C h i n o , C A 9 1 7 1 0 U . S . A . JM T 21 N O V E M B E R , 2 0 1 4 9/ 1 6 " = 1 2 " ( E ) P5.2 PLUMBING DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 6 : 5 1 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 WS CB PLUMBING INSTALLED BY EXHAUST AND INTO FLOOR DRAIN LOOP. DISCHARGE WITH MINIMUM 1" TRAP CONDENSATION TUBE PROVIDE 1/2" PIPE REDUCER TANK REFER TO DETAIL G AND PRESSURE RELIEF VALVE PROVIDE PIPE UNIONS, GROUND JOINT UNION 6" LONG DIRT LEG INSTALL ASME TEMPERATURE VALVE (WHEN REQUIRED) FOR DISSIMILAR METALS DIELECTRIC IF REQUIRED FLOOR DRAIN FURNISHED WITH WATER HEATER COLD WATER SUPPLY TO WATER HEATER HOT WATER TO FIXTURES AS SHOWN ON PLANS CHECK VALVE (TYP) COPPER RELIEF VALVE DISCHARGE LINE FULL SIZE OF OVER FLOOR SINK PVC EXHAUST BY PLUMBING THERMOMETER PROVIDE A HARD EXHAUST ELBOW INSTALLED BY DRAIN VALVE FURNISHED W/ HEATER GAS SHUT-OFF COCK CONTRACTOR MECHANICAL CONTRACTOR GAS-FIRED WATER HEATER PD-N (VERIFY THRU ROOF OR WALL) FLOOR PLANS 10-23-2012 WS DATE: SCALE: DRAWN: NONE TO HEATER, NO PIPE UNION: BUTYL DIAPHRAGM TANK WITH POLYPROPYLENE LINING, FDA APPROVED FOR FILL TANK WITH AIR PRESSURE TO MATCH WATER PRESSURE, WELDED STEEL EXPANSION EXPANSION TANK PD-E1 11-23-2012 WS DATE: SCALE: DRAWN: NONE P5.1 PLUMBING DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 6 : 4 7 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 WS CB P6.1 PLUMBING SCHEDULES FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 7 : 1 3 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 WS CB KROGER PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION BASIS OF DESIGN NOMINAL PIPE SIZE NOTES MISC REMARKS DCW DHW WASTE VENT PL1PC ONE COMPARTMENT SINK A 1/2" 1/2" 2" 1 1/2" PROVIDE FAUCET, STRAINER, VALVES PL1SLND SEAFOOD PREP SINK A 1/2" 1/2" 2" 1 1/2" PROVIDE FAUCET, STRAINER, VALVES PL3-20 THREE COMPARTMENT SINK A 1/2" 1/2" 2" 1 1/2" PROVIDE FAUCET, STRAINER, VALVES PL3C-18NS THREE COMPARTMENT SINK A 1/2" 1/2" 2" 1 1/2" PROVIDE FAUCET, STRAINER, VALVES PLHSW HAND SINK A 1/2" 1/2" 1 1/2" 1 1/2" PROVIDE FAUCET, STRAINER, ANGLE VALVES, P-TRAP, TMV FS-1 FLOOR SINK JAY R SMITH 3200 - - 4" - PC 18" SQ x 12" DEEP NOTES A KROGER FURNISHED EQUIPMENT B NO SUBSTITUTIONS WILL BE ALLOWED x DENOTES TRENCH DRAIN LENGTH IN FEET PC PLUMBING CONTRACTOR PURCHASED AND INSTALLED KROGER SPECIALTIES SCHEDULE MARK DESCRIPTION BASIS OF DESIGN SIZE FLOW GPM PIPE CONNECTION SIZE NOTES REMARKS SAN DCW DHW EXP EXPANSION TANK AMTROL ST-12 A 4.4 TANK VOLUME, 3.2 MAX ACCEPTANCE GT-1 GREASE TRAP PLASTIC TRAPS 50 25 3" - - A LOW PROFILE HB-1 HOSE BIBB WOODFORD MODEL 84 - - - 3/4 - A POLISHED CHROME FINISH, LOOSE TEE KEY OPERATED HB-2 HOSE BIBB WOODFORD MODEL 84 - - - - 3/4 A POLISHED CHROME FINISH, LOOSE TEE KEY OPERATED TMV MIXING VALVE SYMMONS 5-210-CK - - - - - A POINT-OF-USE WCO WALL CLEANOUT SIOUX CHIEF - - - - - A CLEANOUT COVER KIT WHA-A WATER HAMMER SIOUX CHIEF 5 - - 3/4 3/4 A PDI RATING A WHA-B WATER HAMMER SIOUX CHIEF 10 - - 1 1 A PDI RATING B NOTES A PROVIDED BY PLUMBING CONTRACTOR KROGER WATER HEATER SCHEDULE MARK LOCATION BASIS OF DESIGN TANK CAPACITY (GALLONS) GAS INPUT (MBH) EFFICIENCY GPH RECOVERY (100 DEG F) ELECTRICAL DATA KROGER K NUMBER REMARKS KILOWATTS (kW) VOLTS PHASE Hz GWH-1 SEE PLAN LOCHINVAR 200CGN-080-DF9 80 199 80% 194 -120 1 60 060-00044500 PROVIDE WATTS E-100HEAVY DUTY WATER HEATER STAND NOTES A FURNISHED BY KROGER, INSTALLED BY PLUMBING CONTRACTOR KROGER BACKFLOW PREVENTER SCHEDULE MARK LOCATION BASIS OF DESIGN PIPING CONNECTIONS MAXIMUM FLOW GPM DESIGN FLOW GPM MAXIMUM PRESSURE LOSS PSI SYSTEM SERVED NOTES REMARKS DCW DRAIN BFP-1 SEE PLAN WATTS 009LF 3/4" 3/4" 12 6 12 DOMESTIC A REDUCED PRESSURE PROVIDE W/ STRAINER NOTES A PROVIDE FULL SIZE RELIEF DRAIN. VERIFY FLOOR DRAIN WILL HANDLE DISCHARGE B PROVIDE WITH STRAINER C ALL MATERIALS SHALL BE LEAD-FREE M0.1 HVAC COVER SHEET FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 5 : 2 6 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 BASIS OF DESIGN •OUTDOOR SUMMER DESIGN (0.4%): 91 dB / 75 wB •OUTDOOR WINTER DESIGN (99.6%): -3 dB •INDOOR SUMMER DESIGN: 73dB, 45% RH SUMMER, 73dB WINTER, NO HUMIDITY CONTROL AIR TERMINALS 24x24 LAY -IN SUPPLY DIFFUSER OCTAGONAL DROP BOX DIFFUSER RECTANGULAR DROP BOX DIFFUSER VAV DIFFUSER EXHAUST OR RETURN GRILLE SUPPLY DUCT UP EXHAUST OR RETURN DUCT UP ANNOTATION CEILING DIFFUSER- NECK INLET SIZE AND DUCT RUN OUT SIZE UON CFM EXHAUST GRILLE - SIZE CFM VARIABLE AIR VOLUME DIFFUSER CFM CD-8 250 CFM DROP BOX- 6 WAY THROW CFM DROP BOX- 2 WAY THROW CFM SUPPLY DIFFUSER ROUND- DIAMETER CFM ROUND LOUVER DIFFUSER 20"x12" RECTANGULAR DUCT SIZE (CLEAR INSIDE DIMENSIONS) ROUND DUCT DIAMETER 12" ROUND ELBOW CURVED SUPPLY DIFFUSER TAP WITH DAMPER ROUND TAP WITH DAMPER SIZE TO MATCH CD NECK RECTANGULAR ELBOW WITH VANES CURVED SUPPLY DIFFUSER CFM THERMOSTAT/SENSOR T EG- 12X12 200 CFM VAV-DIFF 410 CFM DB-6W 5000 CFM DB-2W 5000 CFM SDR- 30 1900 CFM CSD- 18x20 500 CFM AC-1xx 2 MECHANICAL SYMBOLS DESIGN: CARMEL IN, ELEV: 853'• FLEX DUCT GENERAL NOTES NEW WORK POINT ABBREVIATIONS ACU AIR CONDITIONING UNIT H HUMIDITY AD ACCESS DOOR HP HORSEPOWER AFF ABOVE FINISHED FLOOR HX HEAT EXCHANGER AFG ABOVE FINISHED GRADE KW KILOWATT BTU BRITISH THERMAL UNIT LAT LEAVING AIR TEMPERATURE BFP BACK FLOW PREVENTER MBH 1,000 BTUH PER HOUR CAP CAPACITY MCA MINUMUM CIRCUIT AMPACITY CFH CUBIC FEET PER HOUR MOCP MAXIMUM OVERCURRENT PROTECTION CFM CUBIC FEET PER MINUTE NTS NOT TO SCALE CONT CONTINUATION OA OUTSIDE AIR CO CARBON MONOXIDE OAT OUTSIDE AIR TEMPERATURE CO2 CARBON DIOXIDE OBD OPPOSED BLADE DAMPER CU CONDENSING UNIT MC MECHANICAL CONTRACTOR DB DRY BULB PD PRESSURE DROP DN DOWN PRV PRESSURE REDUCING VALVE E EXISTING PSI POUNDS PER SQUARE INCH EA EXHAUST AIR RA RETURN AIR EAT ENTERING AIR TEMPERATURE REF REFRIGERANT OR REFRIGERATION EC ELECTRICAL CONTRACTOR REQ’D REQUIRED EER ENERGY EFFICIENCY RATIO RH RELATIVE HUMIDITY EF EXHAUST FAN RPM REVOLUTION PER MINUTE EFF EFFICIENCY S SENSOR EH ELECTRIC HEATER SA SUPPLY AIR EMS ENERGY MANAGEMENT SYSTEM SD SMOKE DETECTOR ESP EXTERNAL STATIC PRESSURE SEER SEASONAL ENERGY EFFICIENCY RATIO EXP EXPANSION TANK SP STATIC PRESSURE F FAHRENHEIT T THERMOSTAT FD FIRE DAMPER TSP TOTAL STATIC PRESSURE FLA FULL LOAD AMPERAGE TYP TYPICAL FSD FIRE SMOKE DAMPER UH UNIT HEATER G GAS UON UNLESS OTHERWISE NOTED GA GAUGE VAV VARIABLE AIR VOLUME GPM GALLONS PER MINUTE WB WET BULB AREA TO BE DEMOLISHED MECHANICAL EQUIPMENT TAG DRAWING KEYNOTE A. ALL ROOF PENETRATIONS SHALL BE COMPLETED IN ACCORDANCE WITH ROOFING SYSTEM REQUIREMENTS AND ROOF MANUFACTURERS INSTRUCTIONS. COORDINATE ALL WORK WITH ROOFING CONTRACTOR. B. CONTRACTOR SHALL VERIFY EXACT HEIGHTS OF ALL CEILINGS PRIOR TO START OF WORK. SEE ARCHITECTURAL SHEETS FOR CEILING DETAILS AND CONSTRUCTION. COORDINATE EXACT DUCTWORK INSTALLATION WITH CEILING HEIGHTS AND STRUCTURE AS REQUIRED. C. SEE ELECTRICAL LIGHTING SHEETS FOR EXACT LOCATION OF ALL LIGHT FIXTURES. COORDINATE EXACT DIFFUSER AND GRILLE LOCATIONS WITH LIGHTING FIXTURES AS REQUIRED. D. INSTALL ALL DUCTWORK AS HIGH AS POSSIBLE WHILE COORDINATING WITH ALL OTHER TRADES. OFFSET AND TRANSITION DUCTWORK BETWEEN AND BENEATH STRUCTURAL MEMBERS WHERE REQUIRED. E. ALL DUCTWORK SHALL MEET SMACNA "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE", LATEST EDITION. DUCT GAUGES, REINFORCEMENTS, METHODS OF CONNECTION, TRANSITIONS AND CONSTRUCTION WILL BE FIELD VERIFIED, MEASURED AND INSPECTED FOR COMPLIANCE. DUCTWORK NOT MEETING SMACNA STANDARDS WILL BE REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. UNLESS OTHERWISE NOTED, THE PRESSURE CLASSIFICATION FOR ALL DUCTWORK SHALL BE 2" WATER GAUGE POSITIVE OR NEGATIVE. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS PRIOR TO DUCT FABRICATION. F. ALL DUCTWORK IN EXPOSED SALES AREAS SHALL BE SHEET METAL ONLY, NO FLEX DUCT ALLOWED. FINAL CONNECTIONS TO DIFFUSERS, GRILLES AND REGISTERS SHALL BE SHEET METAL DUCT ONLY. SUPPORT DUCTWORK PER SMACNA AND CODE. FURNISH WITH PAINT-LOC FINISH OR PRIME FOR PAINTING. G. ALL DIMENSIONS ARE LISTED IN INCHES UNLESS OTHERWISE NOTED. H. HVAC CONTRACTOR SHALL FIELD-COORDINATE ALL CONDITIONS, UNIT LOCATIONS, OBSTRUCTIONS AND DUCTWORK INSTALLATION PRIOR TO DUCT FABRICATION. TRANSITION AND OFFSET DUCTWORK AS REQUIRED TO MAKE FIT IN CEILING SPACES AND FIELD CONDITIONS. DUCTWORK FABRICATED BY THE HVAC CONTRACTOR PRIOR TO FIELD COORDINATION AND CONFLICT RESOLUTION SHALL BE AT THE RESPONSIBILITY AND COST OF THE HVAC CONTRACTOR. OWNER SHALL NOT BE RESPONSIBLE FOR SHOP FABRICATED DUCTWORK SIZED DIRECTLY FROM THE HVAC DRAWINGS. I. DO NOT CUT, DRILL HOLES OR REMOVE ANY PORTION OF STRUCTURAL MEMBERS, BEAMS OR PURLINS. ROUTE ALL DUCTWORK, PIPING AND CONDUIT AROUND AND BELOW STRUCTURAL MEMBERS AS REQUIRED. INSTALL DUCTWORK IN ACCORDANCE WITH LATEST SMACNA STANDARDS. J. DO NOT ATTACH SCREWS, NAILS, HANGERS OR FASTENERS OF ANY TYPE TO ROOF DECK. SUPPORT ALL MECHANICAL EQUIPMENT FROM STRUCTURE AND CONTRACTOR - INSTALLED KICKERS ONLY. PROVIDE AND INSTALL INTERMEDIATE KICKERS BETWEEN PURLINS AS REQUIRED TO HANG EQUIPMENT AND SHEET METAL DUCTWORK. K. ALL TEMPERATURE CONTROLS, EMS CONTROLS AND SMOKE DETECTOR SHUT-DOWN WORK SHALL BE COMPLETED BY EMS CONTROLS CONTRACTOR. SEE 'EM' SHEETS FOR ALL ASSOCIATED WORK. L. HVAC CONTRACTOR SHALL FIELD ADJUST ALL DIFFUSERS, REGISTERS AND DRUM LOUVERS DISCHARGE AIRFLOW AWAY FROM ALL OPEN REFRIGERATED CASES, SWAYING SIGNAGE, CHECK STAND/PREP WEIGHT SCALES AND OTHER NOTICEABLE CONFLICTING LOCATIONS AT THE COMPLETION OF CONSTRUCTION (TYP) M. HVAC CONTRACTOR SHALL PROVIDE AND INSTALL PERMANENT ENGRAVED PLASTIC - LAMINATE SIGNS WITH MINIMUM 1"-TALL LETTERING AT ALL ROOFTOP UNITS, EXHAUST FANS AND HVAC EQUIPMENT LOCATIONS THROUGHOUT ENTIRE BUILDING AND ROOFTOP. MOUNT PERMANENTLY IN AN APPROPRIATE AND EFFECTIVE LOCATION, WITH UNIT DESIGNATION AND AREA SERVED SHOWN, PRIOR TO FINAL PUNCH DATE. SEE EMS CONTROL DRAWINGS FOR LABELING OF ALL REMOTE SENSORS, THERMOSTATS AND CONTROL DEVICES. N. HVAC CONTRACTOR SHALL PROVIDE BALANCING DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS WHERE BRANCHES LEAD FROM LARGER DUCTS AS REQUIRED FOR AIR BALANCING. INSTALL MINIMUM OF TWO DUCT WIDTHS FROM BRANCH TAKEOFF. O. HVAC CONTRACTOR SHALL PROVIDE TURNING VANES IN ALL RECTANGULAR DUCTWORK WITH 90 DEGREE MITERED ELBOWS. OD OUTSIDE DIMENSION 24x22 RECTANGULAR DUCT 24"x22" OD FCU FAN COIL UNIT RTU ROOFTOP UNIT LK CB E 1 2 3 4 D C B A T T T T T T RTU-1 4 RTU-2 RTU-3 2 4 4 3 2 2 3 2 5 4 6 SCALE: 3/32"=1'-0" 1 MD1.1 HVAC DEMOLITION PLAN 2 7 1 (TYP.) 2 SF-1 GUH-1 EF-1 GUH-1 CU-1 CU-3 EF-3 MD1.1 HVAC DEMOLITION PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 5 : 5 5 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 KEY NOTES 1 EXISTING TO REMAIN. 2 REMOVE/RELOCATE EXISTING CEILING AIR DEVICE. EXTEND/CONNECT DUCT AS REQUIRED TO ACCOMMODATE NEW LOCATION IN NEW CEILING GRID. 3 REMOVE/RELOCATE EXISTING THERMOSTAT. EXTEND/CONNECT WIRE AS REQUIRED. SEE NEW WORK PLAN FOR NEW LOCATION. 4 EXISTING CONDENSING UNIT TO BE ABANDON IN PLACE. CONTRACTOR TO RECLAIM REFRIGERANT IN STRICT ACCORDANCE WITH LOCAL REQUIREMENTS, CAN AND SEAL AND DISPOSED OF PROPERLY 5 EXISTING EXHAUST FAN TO BE ABANDON IN PLACE. REMOVE ALL ASSOCIATED DUCTWORK - TURN OVER TO OWNER. 6 EXISTING AC UNIT TO BE REMOVE AND TURNED OVER TO KROGER PM. REMOVE REFRIGERANT IN PIPING AND CAP AND SEAL. 7 REMOVE RELOCATE EXISTING DUCTWORK AND AIR DEVICES. SEE NEW WORK PLAN FOR NEW LOCATION. GENERAL NOTES A. REFER TO SHEET M0.1 FOR LEGENDS, ABBREVIATIONS, AND GENERAL NOTES. LK CB EXISTING SYSTEMS / EQUIPMENT / LOCATIONS / CIRCUITING INFORMATION ON THIS DRAWING ARE FROM OWNERS AS-BUILT RECORD DOCUMENTS, AND ARE FOR REFERENCE USE. REFER TO F1 FIXTURE PLAN FOR ADDITIONAL STORE FIXTURE REQUIREMENTS. CONTRACTOR SHALL FIELD VERIFY ALL NECESSARY CIRCUITS FOR REUSE, PRIOR TO DEMOLITION. INFORMATION FROM OWNERS AS-BUILT DOCUMENTS ARE BELIEVED TO BE ACCURATE BUT CONTRACTOR MUST FIELD VERIFY ACCURACY PRIOR TO SUBMITTING BID. E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 M1.1 HVAC PLAN T T T T RTU-1 2 TT 3 2 2 2 3 RTU-2 RTU-3 1 1 1 5 1 1 1 CAP CAP 250 CFM 60 CFM 300 CFM 60 CFM 4 3175 CFM 3175 CFM 2 370 CFM 5 118 ACCT. 117 CUSTOMER SERVICE XXX CHECKLANES 100 SALES 117 MEN 114 STORAGE 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 104 MEAT PREP 102 PRODUCE PREP 101 HALL "C" 111 JANITOR'S CLOSET 116 WOMEN TRANSFER DUCT DETAIL ·22" GAUGE GALVANIZED DUCTWORK ·60" LONG, 14" x 14" OD ·1" INTERNAL INSULATION - ALL SURFACES ·12" x 12" SCREENED OPENING EACH END ·CAULK PENETRATION AT WALL Notes: 6 " 6 " M1.1 HVAC PLAN HVAC DETAILS, AND SCHEDULES FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 5 : 4 2 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES A. REFER TO SHEET M0.1 FOR LEGENDS, ABBREVIATIONS, AND GENERAL NOTES. KEY NOTES 1 EXISTING TO REMAIN. 2 NEW LOCATION OF RELOCATED AIR DEVICE. FIELD VERIFY EXACT LOCATION/DUCT ROUTING.RECONNECT WITH SAME SIZE DUCT. INSULATE TO MATCH EXISTING. COORDINATE WITH EXISTING CONDITIONS. REBALANCE EXISTING AIR DEVICES TO EXISTING CFM. 3 NEW LOCATION OF RELOCATED THERMOSTAT. EXTEND/CONNECT WIRE AS REQUIRED. FIELD VERIFY ROUTING. 4 14x14x60 OD GALVANIZED TRANSFER DUCT WITH 1" LINER. PROVIDE 12X12 SCREENED OPENING ON TOP 6" FROM FROM EACH END FOR TRANSFER ON TOP OF TRANSFER DUCT. LOCATE 6" BELOW DECK AND SEAL OPENING/PENETRATION AROUND DUCT. 5 RELOCATE EXISTING DUCTWORK AND AIR DEVICES. EXTEND AND RECONNECT TO EXISTING SUPPLY FAN. FIELD VERIFY EXACT ROUTING. REBALANCE EXISTING AIR DEVICES TO CFM NOTES. LK CB E0.1 ELECTRICAL COVER SHEET FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 2 : 4 1 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES- POWER GENERAL NOTES- LIGHTING GENERAL NOTES - DEMOLITION ABBREVIATIONS A AMPERES AC ALTERNATING CURRENT IG ISOLATED GROUND A/C AIR CONDITIONING KCMIL THOUSAND CIRCULAR MILS AFF ABOVE FINISHED FLOOR KVA KILOVOLT- AMPERES AFG ABOVE FINISHED GRADE MC METAL CLAD CABLE AFP ABOVE FINISHED PAVEMENT MCB MAIN CIRCUIT BREAKER AHU AIR HANDLING UNIT MCC MOTOR CONTROL CENTER AIC AMPERE INTERRUPTING CAPACITY MDF MAIN DISTRIBUTION FRAME AL ALUMINUM MLO MAIN LUGS ONLY ATS AUTOMATIC TRANSFER SWITCH NEC NATIONAL ELECTRICAL CODE AWG AMERICAN WIRE GAUGE NEMA NAT. ELEC. MANUFACTURERS ASSOC. BEC BUILDING ELECTRICAL CONTRACTOR NL NIGHT LIGHT C CONDUIT P POLE CB CIRCUIT BREAKER PC PLUMBING CONTRACTOR CC CONTROL SYSTEM CONTRACTOR PNL PANEL CT CURRENT TRANSFORMER PWR POWER CU COPPER RC REFRIGERATION CONTRACTOR DC DIRECT CURRENT RMC RIGID METAL CONDUIT DIA DIAMETER RTU ROOF TOP UNIT EF EXHAUST FAN ST SHUNT TRIP EM EMERGENCY UG UNDERGROUND EMT ELECTRICAL METALLIC TUBING UL UNDERWRITERS LABORATORY FEC FIXTURE ELECTRICAL CONTRACTOR V VOLT FLA FULL LOAD AMPERES VA VOLT- AMPERE FMC FLEXIBLE METAL CONDUIT W WATTS OR WIRE GCO GENERAL CONTRACTOR WH WATER HEATER GFCI GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF GND GROUND XFMR TRANSFORMER HC MECHANICAL CONTRACTOR (HVAC) XX" MOUNTING HEIGHT AFF UON UNLESS OTHERWISE NOTED A. REFER TO EQUIPMENT SCHEDULE FOR MOUNTING HEIGHTS AND ADDITIONAL INFORMATION. B. INSTALL ELECTRICAL OUTLETS FOR REFRIGERATION ISLAND CASES IN A STRAIGHT LINE ALIGNED WITH THE HUB DRAWING. COORDINATE WITH PLUMBING DIMENSIONS SIGNED PLAN. C. ALL DIMENSIONS INDICATED ON PLANS THAT ARE FROM INTERIOR PARTITIONS WHERE THE RETURN AIR SHAFT IS INDICATED ARE TAKEN FROM THE SALES AREA SIDE OF THE ROOF DECK HIGH PARTITION, NOT THE RETURN AIR SHAFT PARTITION. D. FIELD COORDINATE UNDER-SLAB CONDUIT AND RACEWAY LAYOUTS WITH ALL AFFECTED DISCIPLINES PRIOR TO SLAB PLACEMENT. E. FLUSH MOUNT ALL WALL OUTLETS IN FOOD PREP AREAS. OUTLETS LOCATED ABOVE STAINLESS STEEL TABLES SHALL BE A MINIMUM OF 46" AFF. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLES FOR ALL 125 VOLT SINGLE PHASE 15 AND 20 AMP OUTLETS INSTALLED IN KITCHEN / FOOD PREP TYPE AREAS. MOUNT ALL WALL OUTLETS IN ALL PREP AREAS HORIZONTALLY. IN ADDITION TO THE ABOVE, PROVIDE WEATHERPROOF COVERS (NEMA 3R WHILE IN USE) FOR ALL OUTLETS IN PRODUCE PREP AND MEAT PREP. F. PROVIDE 10 FEET OF FLEXIBLE CONDUIT FOR REFRIGERATED CASES SERVED FROM WALL JUNCTION BOXES AND 6 FEET FOR ISLAND REFRIGERATED CASES FOR CONNECTION TO CASES BY THE PHASE II EQUIPMENT CONTRACTOR. G. ALL WALL MOUNTED OUTLETS SERVING REFRIGERATED CASES WITH RETURN AIR PLENUM ABOVE SHALL BE ACCESSIBLE (WITH ALL WIRING PLENUM RATED AS / IF APPLICABLE). H. REFER TO ELECTRICAL DIMENSION PLANS FOR GENERAL DIMENSIONAL INFORMATION THAT SHALL ALSO SCHEMATICALLY APPLY FOR CORRESPONDING SYSTEMS WORK. I. CIRCUITS PULLED THRU RACEWAYS SHALL BE 120V UNLESS INDICATED OTHERWISE. J. WIRE CASH REGISTERS (GE38) WITH SEPARATE AND INDEPENDENT CIRCUITS. CIRCUITS SHALL HAVE A SEPARATE AND INDEPENDENT GROUND WIRE, AND SEPARATE AND INDEPENDENT NEUTRAL WIRE (CANNOT BE PHASED OUT AT THE PANEL). EACH BRANCH CIRCUIT FOR CASH REGISTERS SHALL BE AS FOLLOWS: (3) #10 AWG WIRES EACH CASH REGISTER, (1) HOT, (1) NEUTRAL AND (1) INSULATED / ISOLATED GROUND (PLUS EQUIPMENT GROUND). K. DEDICATED ELECTRICAL ISOLATED GROUND PANEL(S) SHALL BE USED EXCLUSIVELY FOR ITEMS SO SPECIFIED - OTHER CIRCUITRY WILL NOT BE PERMITTED IN THIS PANEL. THESE PANELS SHALL BE 208Y/120V, 3-PHASE, 5-WIRE WITH FEEDERS CONSISTING OF (3) HOTS, (1) INSULATED NEUTRAL AND (1) INSULATED AND ISOLATED GROUND (PLUS EQUIPMENT GROUND), WITH GROUND AND NEUTRAL BUSSES INSULATED AND ISOLATED FROM THE PANEL. ALL WIRING DEVICES SERVED BY THE DEDICATED ELECTRIC PANEL SHALL BE EQUIPPED AND WIRED FOR ISOLATED GROUND. L. ALL ELECTRICAL AND COMMUNICATION JUNCTION / OUTLET BOXES SHOWN AGAINST THE WALL SHALL BE MOUNTED IN THE WALL. REFER TO THE ELECTRICAL EQUIPMENT SCHEDULE FOR MOUNTING INFORMATION. M. ROUTE ALL ANTI-SWEAT CIRCUIT HOME-RUNS THROUGH THE PMAC PANEL LOCATED AT THE SOURCE PANELBOARD. ORIGINATE ALL CASE ANTI-SWEAT HEATER CIRCUITS FROM PANELBOARD(S) EXCLUSIVELY USED FOR ANTI-SWEAT HEATER CIRCUITS AND NOT REQUIRING ACCESS BY STORE PERSONNEL. N. PROVIDE NEMA L15-30R TYPE RECEPTACLE FOR ALL MIXERS AND GRINDERS. O. ORIGINATE THE FOLLOWING CIRCUITS FROM PANELBOARD(S) NOT REQUIRING ACCESS BY STORE PERSONNEL: COOLING COILS (COOLERS, FREEZERS, RETARDER, PRODUCE PREP AND MEAT PREP), CASE FANS AND COMBINATION CASE FANS / ANTI-SWEAT HEATERS. P. FURNISH AND INSTALL ALL WIRES AND CABLES. REFRIGERATION CONTRACTOR SHALL MAKE FINAL TERMINATIONS AT BOTH ENDS OF EACH WIRE / CABLE AS APPLICABLE FOR DEFROST AND 208V COOLING COILS. PROVIDE SUFFICIENT SLACK AT BOTH ENDS TO ALLOW FOR SERVICE LOOPS AND TO FACILITATE PROPER TERMINATIONS. ELSEWHERE, INCLUDING POWER WIRING SHOWN ON OTHER DRAWING SHEETS, ELECTRICAL CONTRACTOR SHALL MAKE ALL REQUIRED TERMINATIONS. Q. ALL EXTERIOR SIGN CIRCUITS AND SITE LIGHTING CIRCUITS WITH THE EXCEPTION OF EMERGENCY LIGHTING SHALL ORIGINATE IN ONE ELECTRIC PANEL THAT SHALL BE USED EXCLUSIVELY FOR SIGNAGE AND SITE LIGHTING REQUIREMENTS. PANEL SHALL BE LOCATED IN ECR / DATA CENTER ROOM AND PROGRAMMED BY A LIGHTING CONTROLLER (LCI). SEE SPECS AND ESD DETAILS FOR ADDITIONAL INFORMATION. R. IN GENERAL, RECEPTACLES SHOWN WITHOUT EQUIPMENT MARKING OR OTHER CALLOUT ARE CONVENIENCE OUTLETS THAT SHALL BE MOUNTED AT 18" AFF. S. REGARDLESS OF WHERE JB'S ARE SHOWN ON DRAWINGS, FEED CASES FROM WALL WHEREVER CASES ARE LOCATED AGAINST A WALL. INSTALL WALL OUTLET / JUNCTION BOXES FOR SUCH CASES SO THAT BOTTOMS OF BOXES ARE TWO (2) INCHES ABOVE TOP OF RESPECTIVE CASE (FIELD VERIFY). T. SEE DETAIL "F" ON E5 SERIES DRAWINGS FOR SPECIAL CIRCUITING AND DIMENSIONING REQUIREMENTS THAT APPLY TO REFRIGERATED CASE EQUIPMENT. U. FEC IS RESPONSIBLE FOR ALL NEC REQUIRED LOCAL DISCONNECTING MEANS (NOT FURNISHED WITH EQUIPMENT OR BY KROGER) FOR A COMPLETE INSTALLATION. PROVIDE ALL DISCONNECTING MEANS PER NEC 422.31. V. ALL ELECTRICAL CONDUITS IN THE SALES AREA DESCENDING FROM ROOF FRAMING TO EITHER LOW WALLS OR EQUIPMENT SHOULD BE COORDINATED AND GROUPED TOGETHER WITH OTHER MECHANICAL PIPING. W. ANY ELECTRICAL SERVICE FEEDERS THAT CROSS EXTERIOR WALLS SHALL BE COORDINATED WITH CIVIL DRAWINGS. X. PROVIDE 6 FEET OF FLEXIBLE CONDUIT TO SERVE ISLAND REFRIGERATED CASES CONNECTED TO FLOOR MOUNTED JUNCTION BOXES WITH ELECTRICAL CONDUCTORS RUNNING CONTINUOUSLY THROUGH JUNCTION BOX AND FLEXIBLE CONDUIT FOR CONNECTION TO CASES BY INSTALLING CONTRACTOR. Y. PROVIDE 6 FEET OF SEAL-TIGHT FLEXIBLE CONDUIT TO SERVE REFRIGERATED CASES CONNECTED TO FLOOR MOUNTED PLASTIC (WATER-PROOF) JUNCTION BOXES WITH ELECTRICAL CONDUCTORS RUNNING CONTINUOUSLY THROUGH JUNCTION BOX AND SEAL-TIGHT CONDUIT FOR CONNECTION TO CASES BY INSTALLING CONTRACTOR. Z. ALL FLOOR MOUNTED JUNCTION BOXES IN WASH DOWN, SEAFOOD, MEAT, DELI, AND BAKERY PREP AREAS SHALL BE WEATHERPROOF AND CONDUIT SHALL BE WEATHERPROOF SEAL-TIGHT. AA. ALL DISCONNECT SWITCHES SHALL BE MOUNTED SO OPERATING HANDLE IS CENTERED AT 5'-0" AFF, UNLESS OTHERWISE NOTED. AB. FIELD COORDINATE EXACT ROUTING OF NEW CONDUIT / WIRING SYSTEMS WITH EXISTING CONDITIONS. ADJUST ROUTING TO ACCOMMODATE EXISTING CONDITIONS. ALL NEW CONDUIT / WIRING SYSTEMS SHALL BE CONCEALED ABOVE CEILINGS OR WITHIN WALLS. WHEN ROUTING CONDUIT / WIRING SYSTEMS IN OPEN CEILING AREAS, HOLD CONDUITS AS HIGH AS POSSIBLE. AC. PANELBOARD SCHEDULES CONTAIN INFORMATION FROM CURRENT FIELD PANEL SCHEDULES AND NEW CIRCUIT ASSIGNMENTS. SCHEDULES SHALL BE FIELD VERIFIED AND ANY DISCREPANCIES BETWEEN SCHEDULES AND ACTUAL FIELD WIRING CONDITIONS SHALL BE DOCUMENTED ON RED-LINE AS-BUILT DRAWINGS. REVISED PANELBOARD SCHEDULE CARDS SHALL BE PLACED INTO EACH PANEL UPON COMPLETION OF THE PROJECT. AF. CERTIFIED REFRIGERATION SHOP DRAWINGS MUST BE RECEIVED AND APPROVED PRIOR TO ORDERING ELECTRICAL PANELS, CIRCUIT BREAKERS, FUSES, AND WIRING FOR THE REFRIGERATION UNITS. ANY DEVIATIONS IN ACTUAL APPROVED REFRIGERATION SHOP DRAWINGS VERSUS DESIGN MUST BE VERIFIED AND EQUIPMENT ORDERS ADJUSTED TO MATCH ACTUAL SUBMITTAL DRAWINGS. AG. REFER TO SPECIFICATION 11 41 46 (REFRIGERATION CONTROLS INSTALLATION), FOR WORK REQUIREMENTS. WORK REQUIREMENTS ARE IDENTIFIED IN THE INSTALLER RESPONSIBILITY MATRIX. AH. REFER TO SPECIFICATION 11 41 63 (FIXTURE AND EQUIPMENT ELECTRICAL INSTALLATION) FOR ADDITIONAL INSTALLATION RESPONSIBILITIES. AI. NOTE THAT KEYED NOTES ARE GROUPED BY GENERAL TOPIC AND THAT SOME NUMBERS MAY BE MISSING IN SEQUENCE. SUCH NUMBERS ARE NOT ACCIDENTLY MISSING, THEY ARE NOT USED FOR THIS PROJECT. AJ. "BEC" SHALL REFER TO BUILDING ELECTRICAL CONTRACTOR BIDDING TO THE GENERAL CONTRACTOR, "FEC" SHALL REFER TO FIXTURING ELECTRICAL CONTRACTOR SEPARATELY BIDDING EQUIPMENT TO KROGER. FOR ALL REMODELS AND EXPANSIONS, BEC AND FEC RESPONSIBILITIES WILL BE COMBINED AND FALL TO THE ELECTRICAL CONTRACTOR BIDDING TO THE GENERAL CONTRACTOR. AK. REFER TO HVAC / ELECTRICAL COORDINATION SCHEDULE FOR REQUIREMENTS FOR EQUIPMENT DISCONNECTS, MOTOR CONTROLS, AND CONTROLS. AL. PROVIDE THE FOLLOWING MINIMUM WIRE SIZE TO THE FIRST OUTLET (DEVICE) OF A 15 OR 20 AMP BRANCH CIRCUIT. PROVIDE MINIMUM #10 AWG TO THE LAST OUTLET FOR ALL BRANCH CIRCUITS MORE THAN 200 FEET IN LENGTH. UP TO 50 FEET # 12 50 TO 200 FEET # 10 MORE THAN 200 FEET # 8 MINIMUM PROVIDE MINIMUM AWG CONDUCTOR SIZE FOR GENERAL BRANCH CIRCUITING AS FOLLOWS. WHERE APPLICABLE INCREASE AS REQUIRED TO ACCOMMODATE VOLTAGE DROP. OVERCURRENT CU AWG OVERCURRENT CU AWG 15 / 20 AMPERE # 12 60 / 70 AMPERE # 4 25 / 30 AMPERE # 10 80 AMPERE # 3 40 AMPERE # 8 90 AMPERE # 2 50 AMPERE # 6 100 AMPERE # 1 AM. ELECTRICAL CONTRACTOR RESPONSIBILITIES FOR KROGER FURNISHED MATERIAL SHALL BE AS FOLLOWS: 1. RECEIVE, UNLOAD, STORE, AND PROTECT PRODUCT ON SITE. 2. INSPECT PRODUCTS UPON RECEIPT FOR SHORTAGES, DAMAGES, DEFECTS, AND NOTIFY SUPPLIER (AND KROGER) WITHIN 24 HOURS. 3. NOTIFY SUPPLIER (AND KROGER) WITHIN 20 DAYS OF RECEIPT OF ANY HIDDEN DAMAGES FOR PRODUCTS REVIEWED. A. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR FIXTURE LOCATIONS AND PLACEMENT. B. ALL EXTERIOR LIGHTING AND SIGN CIRCUITS SHALL BE CONTROLLER THROUGH EXISTING SYSTEMS. C. ALL FLUORESCENT LAMPS SHALL BE 3500K LAMPS, FURNISHED BY KROGER UNLESS NOTED OTHERWISE. D. FLUORESCENT FIXTURES IN BACKROOM AREAS SHALL BE INSTALLED 16'-0" ABOVE FLOOR OR ON BOTTOM OF ROOF STRUCTURE. E. TYPE "M8" SHALL BE LOCATED OVER GRINDER IN THE COOLER. THIS FIXTURE SHOULD BE ON LIFE SAFETY. CODE REQUIRES 60 FC OVER THE GRINDER, 10 FC THROUGHOUT. IF THE GRINDER IS NOT LOCATED INSIDE THE COOLER, USE ONLY TYPE "M10" TO ACHIEVE LIGHT LEVEL. F. NO SURFACE MOUNTED ELECTRICAL CONDUITS PERMITTED TO BE EXPOSED IN MEAT OR PRODUCE PREP AREA. G. MINIMIZE EXPOSED SURFACE MOUNTED ELECTRICAL CONDUITS LOCATED IN WALK-IN COOLER AND FREEZER. H. ALL CONDUITS FOR PREP ROOM LIGHTING SHALL BE RUN ON TOP OF INSULATED ROOF PANEL AND STUBBED THROUGH PANEL INTO LUMINAIRE AT EACH LUMINAIRE LOCATION. REFER TO ESD-26 ON E5-SERIES DRAWINGS. I. FIELD COORDINATE EXACT ROUTING OF NEW CONDUIT / WIRING SYSTEMS WITH EXISTING CONDITIONS. ADJUST ROUTING TO ACCOMMODATE EXISTING CONDITIONS. ALL NEW CONDUIT / WIRING SYSTEMS SHALL BE CONCEALED ABOVE CEILINGS OR WITHIN WALLS. WHEN ROUTING CONDUIT / WIRING SYSTEMS IN OPEN CEILING AREAS, HOLD CONDUITS AS HIGH AS POSSIBLE. J. LIGHTING FIXTURES TO BE DEMOLISHED AS WELL AS CONDUIT / WIRING SYSTEMS SHALL BE REMOVED BACK TO LAST ACTIVE JUNCTION / TERMINATION BOX. IF TERMINATION POINT DOES NOT EXIST, REMOVE CONDUIT / WIRING BACK TO SOURCE. K. ALL EXISTING LIGHTING FIXTURES THAT REMAIN SHALL BE CLEANED AND RELAMPED. ANY BALLAST THAT ARE DEFECTIVE SHALL BE REPLACED. L. REFERENCE DEMOLITION SHEETS AND NEW WORK SHEETS FOR COMPLETE WORK DETAILS. M. PANELBOARD SCHEDULES CONTAIN INFORMATION FROM CURRENT FIELD PANEL SCHEDULES AND NEW CIRCUIT ASSIGNMENTS. SCHEDULES SHALL BE VERIFIED AND ANY DISCREPANCIES BETWEEN SCHEDULES AND ACTUAL FIELD WIRING CONDITIONS SHALL BE DOCUMENTED ON RED-LINE AS-BUILT DRAWINGS AND UPDATED PANELBOARD SCHEDULES CARDS SHALL BE PLACED INTO EACH PANEL UPON COMPLETION OF THE PROJECT. N. WHERE APPLICABLE, MOUNT LUMINAIRES AS CLOSE TO THE BOTTOM OF THE UNISTRUT SUPPORTING THE REFRIGERATION PIPING IN THE BACK AREAS. ELSEWHERE MOUNT LUMINAIRES IN-BETWEEN BAR JOISTS TO PROJECT FROM DAMAGE IN THE BACK AREAS. PROVIDE MINIMUM CLEARANCE OF 16'-0" AFF. O. PROVIDE PROTECTIVE CLEAR SAFETY SHIELDS FOR ALL EXPOSED FLUORESCENT LAMPS IN FOOD PREP AREAS (SEE SPECIFICATIONS). P. EXIT SIGNS TO BE SURFACE MOUNTED WHEREVER POSSIBLE. MOUNT OPEN CEILING SALES FLOOR EXIT SIGNS AT 12'-0" AFF OR 2'-0" BELOW MAIN LUMINAIRE MOUNTING HEIGHT IN AREA, WHICHEVER IS LOWER. VERIFY MOUNTING HEIGHT PRIOR TO INSTALLATION WITH LOCAL AUTHORITY HAVING JURISDICTION. Q. PROVIDE THE FOLLOWING MINIMUM WIRE SIZE TO THE FIRST FIXTURE OF A 20 AMP LIGHTING BRANCH CIRCUIT. PROVIDE MINIMUM #10 AWG TO THE LAST FIXTURE FOR ALL CIRCUITS MORE THAN 200 FEET IN LENGTH. UP TO 50 FEET # 12 50 TO 200 FEET # 10 MORE THAN 200 FEET # 8 MINIMUM R. ELECTRICAL CONTRACTOR RESPONSIBILITIES FOR KROGER FURNISHED MATERIAL SHALL BE AS FOLLOWS: 1. RECEIVE, UNLOAD, STORE, AND PROTECT PRODUCT ON SITE. 2. INSPECT PRODUCTS UPON RECEIPT FOR SHORTAGES, DAMAGES, DEFECTS, AND NOTIFY SUPPLIER (AND KROGER) WITHIN 24 HOURS. 3. NOTIFY SUPPLIER (AND KROGER) WITHIN 20 DAYS OF RECEIPT OF ANY HIDDEN DAMAGES FOR PRODUCTS REVIEWED. A. ----- (DASHED) OR HATCHED = WORK TO BE REMOVED BY ELECTRICAL CONTRACTOR. B. SEE ELECTRICAL SPECIFICATIONS FOR FURTHER GENERAL DEMOLITION RELATED REQUIREMENTS. COORDINATE ALL WORK CAREFULLY WITH OWNER'S REPRESENTATIVE(S). THE FOLLOWING NOTES APPLY FOR ALL ELECTRICAL SYSTEMS. C. SELECTIVELY DISCONNECT AND REMOVE ALL ABANDONED EXISTING ELECTRICAL WORK THROUGHOUT THE FACILITY, AS REQUIRED TO ACCOMMODATE NEW WORK OF ALL TRADES, NEW LAYOUTS, REPLACEMENT SYSTEMS, ETC. REMOVE RELATED CONDUIT AND WIRING BACK TO NEAREST CONCEALED ACCESSIBLE JUNCTION BOX "UPSTREAM". EXTEND CONDUIT, WIRING, ETC. AS REQUIRED TO ACCOMMODATE NEW OR RELOCATED ELECTRICAL WORK. REMOVE ALL ABANDONED WIRING/CABLING BACK TO RESPECTIVE SOURCE. D. IN WALLS AND CEILINGS THAT ARE TO BE DEMOLISHED, DISCONNECT AND REMOVE ALL EXISTING FIXTURES, DEVICES, WIRING, OUTLET BOXES, JUNCTION BOXES, CONDUIT, ETC. REMOVE ALL RELATED WIRING BACK TO SOURCE. E. IN WALLS AND CEILINGS THAT ARE TO REMAIN IN RENOVATION AREAS, DISCONNECT AND REMOVE ALL EXISTING FIXTURES, DEVICES, WIRING AND CONDUIT FOR ABANDONED ELECTRICAL WORK. REMOVE ALL RELATED WIRING BACK TO SOURCE. REMOVE OUTLET BOXES AND NEATLY PATCH FINISHED SURFACE IN ALL AREAS THAT WILL RECEIVE NEW FINISHES AND BE OCCUPIED AFTER RENOVATION. IN UNFINISHED AREAS, OUTLET BOXES MAY REMAIN - PROVIDE BLANK WALL PLATES. THIS NOTE ALSO APPLIES FOR EXISTING WORK THAT WILL BE RENDERED INACCESSIBLE BY NEW FURNITURE AND EQUIPMENT LAYOUT. F. NOTE THAT ADDITIONAL ELECTRICAL DEMOLITION RELATED WORK IS REQUIRED, ABOVE AND BEYOND THE WORK INDICATED ON THIS SHEET. REFER TO SPECIFICATIONS. G. DASHED ARCHITECTURAL LINES INDICATE WALLS, DOORS, ETC. TO BE REMOVED BY OTHERS. H. REMOVE ALL SURFACE MOUNTED BOXES, CONDUIT AND RACEWAY ASSOCIATED WITH ELECTRICAL DEMOLITION OF ANY EQUIPMENT/DEVICE SERVED FROM SAME. I. PROVIDE NEW DEVICES AND WALL PLATES FOR ALL RE-USED SWITCH / RECEPTACLE LOCATIONS, INDOOR AND OUTDOOR. REFER TO NEW WORK DRAWINGS TO DETERMINE IF SUCH DEVICE REPLACEMENTS SHALL INCLUDE SPECIAL REQUIREMENTS SUCH AS GFIC RECEPTACLES, TVSS RECEPTACLES, QUADS, ETC. FIELD SURVEY THE ENTIRE FACILITY PRIOR TO SUBMITTING A BID SINCE NOT ALL SUCH EXISTING DEVICES ARE INDICATED ON DRAWINGS. J. EXISTING WORK SHOWN HAS BEEN DERIVED FROM RECORD DOCUMENTS, AND HAS BEEN VERIFIED TO THE BEST OF OUR ABILITY. THIS WORK IS SHOWN FOR GENERAL SCHEMATIC PLANNING REFERENCE; IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REVIEW ALL EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. 1) WHERE APPLICABLE, ELECTRICAL CONTRACTOR MAY RE-USE EXISTING CONDUIT / ROUTING WHERE EXISTING CONDUIT (TYPE, MATERIAL, ETC.) MEETS SPECIFICATION STANDARDS. E.C. SHALL REMOVE ALL ABANDONED CONDUIT NOT USED IN THIS MANNER. K. PROVIDE NEW CONDUIT/RACEWAY / DROPS, WALL OUTLET BOXES, WIRING, FITTINGS, ETC. AS NECESSARY TO FULFILL NEW WORK REQUIREMENTS. DETERMINE EXACT CONDITIONS/REQUIREMENTS IN FIELD AND PROVIDE ALL REQUIRED WORK. L. PROVIDE ALL REQUIRED ELECTRICAL DISCONNECTIONS AND RECONNECTIONS FOR ALL CASES AND EQUIPMENT THAT ARE LOCATED IN AREAS WHERE NEW OR REPLACEMENT FLOORING MATERIALS OR FINISHES ARE BEING INSTALLED. M. PROVIDE COMPLETE ELECTRICAL DEMOLITION AS REQUIRED FOR THE LIGHTING, POWER AND SYSTEMS WORK THROUGHOUT ALL PROJECT AREAS. UNLESS SPECIFICALLY NOTED OTHERWISE ON PLANS OR DETERMINED OTHERWISE DURING THIS CONTRACTOR'S PRE-DEMOLITION SURVEY, ALL ABANDONED EXISTING ELECTRICAL WORK IN THE PROJECT AREAS SHALL BE DISCONNECTED AND REMOVED IN ITS ENTIRETY BY THE ELECTRICAL CONTRACTOR. ALL RELATED WORK SHALL COMPLY WITH THE NOTES SPECIFIED HEREAFTER. N. IT IS NOT THE INTENT OF THESE CONTRACT DOCUMENTS THAT EXISTING CONDITIONS BE ACCURATELY SHOWN. EXISTING ELECTRICAL WORK IS SHOWN TO A LIMITED EXTENT ON DRAWINGS AND IS SHOWN FOR GENERAL PLANNING/SCHEMATIC REFERENCE ONLY. THE ACCURACY OF THE LOCATIONS AND QUANTITIES SHOWN IS NOT GUARANTEED. O. PRIOR TO SUBMITTING A BID, THE ELECTRICAL CONTRACTOR SHALL PERFORM A DETAILED WALK-THROUGH FIELD INSPECTION, TO REVIEW THE EXISTING STRUCTURES AND PREMISES, TO DETERMINE ALL EXISTING CONDITIONS, DEVICE/EQUIPMENT LOCATIONS, ETC., AND TO COMPARE THE ABOVE WITH CONTRACT DOCUMENTS AS REQUIRED TO MAKE ALL NECESSARY BASE BID ALLOWANCES FOR ALL REQUIRED ELECTRICALLY RELATED DEMOLITION AND NEW CONSTRUCTION WORK. NO SUBSEQUENT ALLOWANCE TO THE CONTRACT COST WILL BE MADE FOR ANY ERRORS OR OMISSIONS RESULTING FROM INSUFFICIENT REVIEW OF EXISTING CONDITIONS BY THE ELECTRICAL CONTRACTOR. P. PROVIDE ALL NECESSARY DEMOLITION RELATED WORK AS REQUIRED TO CLEAR AND REMOVE ALL EXISTING ELECTRICAL WORK TO BE ABANDONED AND AS REQUIRED TO ACCOMMODATE ALL NEW WORK OF ALL TRADES. IN GENERAL, REMOVE ALL ABANDONED CONDUIT AND WIRING. EXTEND CONDUIT, WIRING, ETC., AS REQUIRED TO ACCOMMODATE NEW OR RELOCATED ELECTRICAL WORK. WHERE WIRING EXTENSIONS ARE REQUIRED FOR LOW VOLTAGE SYSTEMS WORK, COORDINATE IN ADVANCE WITH RESPECTIVE EQUIPMENT / SYSTEM VENDOR TO ENSURE THAT SPLICING METHODS WILL NOT COMPROMISE THE INTEGRITY OF THE SYSTEM. Q. IT IS RECOGNIZED THAT THERE MAY BE SOME CONDUIT SYSTEMS RENDERED INACTIVE BY DEMOLITION, CAUSING DISCONNECTION OF "DOWNSTREAM" OUTLETS, ETC. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INVESTIGATE THESE TYPES OF CONDITIONS (FOR ALL SYSTEMS) PRIOR TO DEMOLITION. PROVIDE ALL NECESSARY CORRECTIVE ELECTRICAL WORK PRIOR TO DEMOLITION TO ENSURE THAT SUCH "DOWNSTREAM" DEVICES REMAIN PERMANENTLY ACTIVE THROUGHOUT DEMOLITION, NEW CONSTRUCTION AND AFTER PROJECT COMPLETION. R. ALL WIRING, DEVICES, CONDUIT, ETC., CONFLICTING WITH CONSTRUCTION RELATED WORK OF ANY AND ALL TRADES SHALL BE REMOVED AND/OR RELOCATED BY THE ELECTRICAL CONTRACTOR AS NECESSARY AND/OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE IN THE FIELD. ELECTRICAL DISCONNECTIONS (AND / OR RECONNECTIONS) FOR EQUIPMENT TO BE REMOVED (AND / OR RELOCATED) BY OTHER TRADES SHALL BE MADE BY THE ELECTRICAL CONTRACTOR. S. EXCEPT WHERE REUSE IS INDICATED, REFER TO OWNER FOR DISPOSITION REQUIREMENTS OF ALL REMOVED ELECTRICAL EQUIPMENT. FOR EQUIPMENT TO BE REUSED AND EQUIPMENT WHICH THE OWNER ELECTS TO RETAIN, PROTECT AND TRANSPORT SAME TO AN OWNER DESIGNATED AREA ON SITE AS DIRECTED IN FIELD. ALL REUSE EQUIPMENT SHALL BE CLEANED, CHECKED FOR PROPER OPERATION AND REINSTALLED AS INDICATED IN PROJECT MANUAL OR ON DRAWINGS. T. ELECTRICAL EQUIPMENT TO BE REUSED AND SALVAGE MATERIALS RETAINED BY OWNER SHALL BE CAREFULLY REMOVED (UNDAMAGED) AND TURNED OVER TO OWNER. DISCONNECT (NOT JUST CUT) ALL WIRING AND "WHIPS" FROM EQUIPMENT TERMINAL POINTS AND CAREFULLY TRANSPORT TO AND NEATLY STORE AT AN ON-SITE STORAGE LOCATION AS DIRECTED IN FIELD. COMPONENTS SHALL BE NEATLY STORED AS GROUPS BY SYSTEM TYPE. U. UNLESS DIRECTED OTHERWISE IN FIELD, ALL OTHER ELECTRICAL DEMOLITION MATERIALS SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR WHO SHALL PROMPTLY REMOVE SAME FROM THE JOB SITE AND LEGALLY DISPOSE OF SAME. V. REFER TO ARCHITECTURAL DRAWINGS FOR MORE SPECIFIC DEFINITIONS OF DEMOLITION AREAS. REFER TO DRAWINGS OF ALL TRADES FOR ELECTRICALLY RELATED DEMOLITION WORK WHICH MAY BE REQUIRED. W. ALL ABANDONED CONDUITS SHALL BE CLEARED BACK TO RESPECTIVE SOURCES, EVEN IF SOURCES ARE OUTSIDE OF THE CONFINES OF THE PROJECT AREA. UNLESS DIRECTED OTHERWISE IN FIELD, ALL ABANDONED SYSTEMS CABLES SHALL BE DISCONNECTED AT BOTH ENDS AND REMOVED BACK TO RESPECTIVE SOURCES, EVEN IF SOURCES ARE OUTSIDE OF THE CONFINES OF THE PROJECT AREA. COORDINATE ALL WORK CAREFULLY WITH OWNER PRIOR TO BEGINNING ANY ELECTRICAL DEMOLITION WORK. X. DETERMINE IN FIELD WHICH OF THE EXISTING BRANCH CIRCUITS WILL REMAIN ACTIVE. RECONNECT AND SCHEDULE SAME AS REQUIRED. EXISTING BRANCH CIRCUIT WIRING, NOT CONFLICTING WITH NEW CONSTRUCTION, MAY BE REUSED AT THE DISCRETION OF THE ELECTRICAL CONTRACTOR. IF SO, ENSURE THAT ALL REUSED SHARED NEUTRALS ARE PROPERLY BALANCED WITH THE RIGHT PHASE CONDUCTORS, ENSURE THAT CONDUCTOR INSULATION IS PROPERLY COLOR-CODED FOR ALL REUSED CONDUCTORS, AND ENSURE ALL CIRCUIT IDENTIFICATION BANDS ARE CORRECT ON ALL CONDUCTORS. RETYPE PANELBOARD DIRECTORIES FOR ALL PANELBOARDS AFFECTED BY THIS PROJECT. Y. PROVIDE NEW CONDUIT AS REQUIRED. ROUTING OF ALL NEW EXPOSED CONDUIT WORK IN THE EXISTING BUILDING SHALL BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION AND SHALL BE MOUNTED AS HIGH AS POSSIBLE IN ALL CASES. ALL WIRING SHALL BE NEW. EXISTING BRANCH CIRCUIT AND SYSTEMS CONDUIT, NOT CONFLICTING WITH NEW CONSTRUCTION, MAY BE REUSED AT THE DISCRETION OF THE ELECTRICAL CONTRACTOR. DO NOT EXCEED NEC REQUIRED CONDUIT FILL AND DO NOT INSTALL WIRING FED FROM DIFFERENT SOURCES IN COMMON CONDUIT (SEE SPECIFICATIONS). Z. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND MAINTAIN TEMPORARY LIGHTING AND POWER WITHIN THE CONSTRUCTION SPACE. DERIVE TEMPORARY POWER FROM A LOCAL PANELBOARD AS DIRECTED BY OWNER'S REPRESENTATIVE. OWNER SHALL PAY FOR CURRENT FOR ALL TRADES. REFER TO GENERAL CONDITIONS. PROVIDE MINIMUM OF 10 FOOTCANDLES OF LIGHT AND PROVIDE GFI PROTECTION. INSTALLATION METHODS SHALL BE PER NEC. ALL PERMANENT WIRING SHALL BE INSTALLED IN CONDUIT. TEMPORARY BRANCH CIRCUIT POWER WIRING FOR PHASED CONSTRUCTION SHALL BE INSTALLED IN CONDUIT. TEMPORARY LOW VOLTAGE WIRING FOR PHASED CONSTRUCTION IS NOT REQUIRED TO BE INSTALLED IN CONDUIT, BUT MUST BE REMOVED AS SOON AS IT IS ABANDONED. PROVIDE ALL REQUIRED TEMPORARY POWER AND SYSTEMS WIRING/CONNECTIONS AS REQUIRED FOR ALL TEMPORARY OCCUPANCY AREA WHICH WILL BE USED TO ACCOMMODATE THE MULTIPLE CONSTRUCTION PHASES. AA. ALL WORK AND SYSTEM SHUTDOWNS SHALL BE CAREFULLY COORDINATED IN ADVANCE WITH OWNER'S REPRESENTATIVE AND ALL AFFECTED TRADES SO THAT NORMAL BUILDING ACTIVITIES AND OTHER CONSTRUCTION TRADES ARE MINIMALLY AFFECTED. ALL REQUIRED ELECTRICALLY RELATED DEMOLITION AND/OR NEW CONSTRUCTION WORK, WHICH WILL AFFECT ANY AND ALL OCCUPIED AREAS (INCLUDING THOSE WHICH ARE LOCATED OUTSIDE THE IMMEDIATE AREA OF PROJECT WORK) SHALL BE PERFORMED AT SPECIAL TIMES IF / AS DIRECTED BY OWNER'S REPRESENTATIVE IN FIELD. AB. WHERE INDICATED ON DRAWINGS, REMOVE EXISTING DEVICES, FIXTURES, EQUIPMENT, ETC. IN AFFECTED AREAS AND PROTECT DURING DEMOLITION AND CONSTRUCTION PHASES. CLEAN AND REINSTALL / RELOCATE THESE EXISTING DEVICES AS INDICATED ON DRAWINGS. MODIFY AND / OR EXTEND RELATED EXISTING WIRING IN CONDUIT AS REQUIRED. EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE HEREIN OR ON DRAWINGS, ALL ELECTRICAL WORK SHOWN ON NEW WORK PLANS SHALL BE NEW. AC. IF ANY EXISTING CODE OR SAFETY VIOLATIONS ARE DISCOVERED BY THE ELECTRICAL CONTRACTOR, THEY SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION (DETAILED IN WRITING) OF THE OWNER'S REPRESENTATIVE ALONG WITH THE CONTRACTOR'S PROPOSED COST FOR CORRECTIONS. AD. INDICATED LIGHTING FIXTURES TO BE DEMOLISHED AS WELL AS CONDUIT / WIRING SYSTEMS SHALL BE REMOVED BACK TO LAST ACTIVE JUNCTION / TERMINATION BOX. IF TERMINATION POINT DOES NOT EXIST, REMOVE CONDUIT / WIRING BACK TO SOURCE. AE. ALL EXISTING LIGHTING FIXTURES THAT REMAIN SHALL BE CLEANED AND RELAMPED. ANY BALLAST THAT ARE DEFECTIVE SHALL BE REPLACED. AF. REFERENCE DEMOLITION SHEETS AND NEW WORK SHEETS FOR COMPLETE WORK DETAILS. AG. ELECTRICAL PANELS SHOWN FOR REFERENCE, UNLESS OTHERWISE NOTED FOR ADDITIONAL WORK. IDF INTERMEDIATE DISTRIBUTION FRAME RCP RECIRCULATION PUMP VIF VERIFY IN FIELD J J DUPLEX RECEPTACLE, MOUNTED 18" AFF UON FLOOR MOUNTED DUPLEX RECEPTACLE, MOUNTED 18" AFF UON CEILING MOUNTED DUPLEX RECEPTACLE CEILING MOUNTED, THREE PHASE SPECIAL RECEPTACLE SURFACE MOUNT ELECTRICAL PANEL, AS INDICATED ON PLANS AND SCHEDULES CEILING MOUNTED POWER CORD REEL QUAD RECEPTACLE, MOUNTED 18" AFF UON WALL MOUNTED, THREE PHASE SPECIAL RECEPTACLE, MTD. 18" AFF UON CEILING MOUNTED, SINGLE PHASE SPECIAL RECEPTACLE WALL MOUNTED, SINGLE PHASE SPECIAL RECEPTACLE, MTD 18" AFF UON CEILING MOUNTED JUNCTION BOX WALL MOUNTED JUNCTION BOX RECESSED MOUNT ELECTRICAL PANEL, AS INDICATED ON PLANS AND SCHEDULES XX X XXX J EM M DB NON FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH COMBINATION DISCONNECT/STARTER TELEPHONE/POWER POLE (TUBE STEEL CHASE FURNISHED BY KROGER, INSTALLED BY BEC) LA1-1 XX-XX M MANUAL MOTOR STARTER LIGHTING GENERATOR EPO DUPLEX RECEPTACLE, OWNER TAG / ID OF EQUIPMENT SERVED GE56C-32 2' X 4' RECESSED TROFFER 2' X 4' RECESSED TROFFER ON EMERGENCY CIRCUIT 1' X 4' RECESSED TROFFER 3' NARROW STRIP LIGHT 8' STANDARD STRIP LIGHT EMERGENCY WALL PACK 8' PENDANT MOUNTED DIRECT/INDIRECT LIGHT 7" RECESSED DOWNLIGHT 7" RECESSED DOWNLIGHT ON EMERGENCY CIRCUIT 8' VAPORTIGHT INDUSTRIAL SURFACE MOUNTED LIGHT 8' VAPORTIGHT INDUSTRIAL SURFACE MOUNTED LIGHT ON EMERGENCY CIRCUIT 4' VAPORTIGHT INDUSTRIAL SURFACE MOUNTED LIGHT EXTERIOR WALL PACK TRACK MOUNTED WALL WASHER LED TRACK HEAD LED TRACK HEAD EXIT SIGN EXIT SIGN WITH CHEVRON TO ONE SIDE SPECIALTY LIGHTING TRACK. REFER TO SPECIALTY LIGHTING PLAN FOR EXACT LENGTHS POWER 3 TS1 US1 MS1 DRAWING NOTE, XX = DRAWING NOTE DESIGNATION PARTIAL PLAN DETAIL BUBBLE, X = DETAIL NUMBER, XXX = SHEET NUMBER WHERE DETAIL IS LOCATED CONNECTION POINT TRANSFORMER ELECTRICAL PANELBOARD DIRECT BUY - FURNISHED BY KROGER, INSTALLED AND WIRED BY BUILDING ELECTRICAL CONTRACTOR JUNCTION BOX GROUND ONE-WAY OCCUPANCY SENSOR, CEILING-MOUNTED ULTRASONIC WALL SWITCH, 20 SQ FT COVERAGE PASSIVE INFRARED WALL SWITCH, 30 SQ FT COVERAGE MOTOR, M = MOTOR HORSEPOWER RATING CIRCUIT BREAKER LIGHTING/POWER HOMERUN WITH PANELBOARD AND CIRCUIT CALLOUT UNDERFLOOR RACEWAY SYSTEM WITH JUNCTION BOX CONNECTION UNDERFLOOR RACEWAY SYSTEM END PLUG UNDERFLOOR RACEWAY SYSTEM AS DEFINED ON PLAN DRAWINGS AND DETAILS FEEDER TYPE, REFER TO FEEDER SCHEDULE FOR DETAILS EQUIPMENT MANUFACTURER - FURNISHED BY EQUIPMENT MANUFACTURER. INSTALLED AND WIRED BY BUILDING ELECTRICAL CONTRACTOR SWITCHING SINGLE POLE LIGHT SWITCH 3-WAY LIGHT SWITCH SINGLE POLE TIMER SWITCH SINGLE LINE DIAGRAM MISCELLANEOUS EXISTING WORK NEW WORK ANNOTATION TS3 THREE WAY TIMER SWITCH DISCONNECT SWITCH SIZE FUSE SIZE, ** REPRESENTS SIZING PER EQUIPMENT NAME PLATE DATA FLOOR MOUNTED JUNCTION BOX J ELECTRICAL SYMBOLS EXISTING LIGHT TO BE REMOVED CL # TRACK MOUNTED CURRENT LIMITER, # REPRESENTS CURRENT LIMITER AMPACITY EXISTING WORK TO BE REMOVED OS2 OS1 TWO-WAY OCCUPANCY SENSOR, SUSPENDED AT 12'-6" AFF M01 MOMENTARY OVERRIDE LIGHT SWITCH OS3 TWO-WAY OCCUPANCY SENSOR, SUSPENDED AT 12'-6" AFF OS4 TWO-WAY OCCUPANCY SENSOR, SUSPENDED 15'-6" AFF OS5 ONE-WAY, WIDE-ANGLE OCCUPANCY SENSOR, CASE MOUNTED 1-CASE CONNECTION 2-CASE CONNECTION 3-CASE CONNECTION AM CB EXISTING FIRE ALARM SYSTEM SHALL REMAIN AND BE UPDATED AS REQUIRED FOR BUILDING MODIFICATIONS. COORDINATED ANY CHANGES WITH KROGER PM FOR APPROVAL. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEVELOPING PLANS AND SUBMITTING FOR PERMITTING. FIRE ALARM NOTE E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 ED1.1 ELECTRICAL LIGHTING DEMOLITION PLAN 2 2 2 4 3 4 4 4 TYP THIS GROUP OF LIGHTS 3333 33333 4 4 4 1 TYP FOR ALL LIGHTING UNLESS OTHERWISE TAGGED 4 ED1.1 ELECTRICAL LIGHTING DEMOLITION PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 3 : 5 6 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 KEY NOTES GENERAL NOTES A. REFER TO SHEET E0.1 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. 1. EXISTING LIGHTING TO REMAIN. 2. EXISTING LIGHTING FIXTURE TO BE RAISED TO BOTTOM OF CEILING BEAM, COORDINATE RE-POSITIONING OF THIS FIXTURE WITH COOLER / FREEZER BOX AND REFRIGERATION EQUIPMENT INSTALLATION. 3. EXISTING LIGHTING FIXTURES TO BE REPOSITIONED FOR CEILING WORK, COORDINATE WORK WITH GENERAL CONTRACTOR. 4. EXISTING LIGHTING TO BE REMOVED AND RETAINED FOR RE-INSTALLATION WHEN SPACE IS TO TURNED BACK OVER TO LANDLORD UPON COMPLETION OF KROGER USE. EXISTING SYSTEMS / EQUIPMENT / LOCATIONS / CIRCUITING INFORMATION ON THIS DRAWING ARE FROM OWNERS AS-BUILT RECORD DOCUMENTS, AND ARE FOR REFERENCE USE. REFER TO F1 FIXTURE PLAN FOR ADDITIONAL STORE FIXTURE REQUIREMENTS. CONTRACTOR SHALL FIELD VERIFY ALL NECESSARY CIRCUITS FOR REUSE, PRIOR TO DEMOLITION. INFORMATION FROM OWNERS AS-BUILT DOCUMENTS ARE BELIEVED TO BE ACCURATE BUT CONTRACTOR MUST FIELD VERIFY ACCURACY PRIOR TO SUBMITTING BID. AM CB E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 ED1.2 ELECTRICAL POWER DEMOLITION PLAN LP3-10 LP1-23 LP2-31 LP2-25 LP2-3 LP3-7 LP2-31 LP2-28 LPCR-1 LP1-23 LPCR-3 LP2-3 LP2-3 LP2-5 LP2-5 LP2-5 LP2-27 LP2-29 LP2-39 LP2-39 LP2-1 LP2-1 LP2-1 LP2-41 LP2-41 LP2-41 LP3-10 LPSP-30 LPSP-28 MDP LP3-14 LP3-12 LP3-14 LP3-12 MDP LP2-35 LP2-37 LP4-13 LP2-29 LP4-15 LP2-29 LP4-19 LP4-17 LP3-5 LP2-1 LP2-1 LP2-7 LP2-25 LP1-23 LP2-37 LP2-35 LP2-35 LP4-13 LP4-13 LP4-13 LP4-15 LP4-17 LP4-17 LP4-19 LP4-24,26 LP4-28 LP4-13 LP4-15 LP4-13 LP4-13 LP4-15 LP4-19 LP4-17 LP4-17 LP4-15 LP2-39 LP4-13 LP1-23 LP2-35 LP2-37 ED1.2 2 ED1.2 3 ED1.2 4 1 1 1 1 2 2 2 2 2 LP4-16 LP4-39 LP4-37 LPCR-11 LPCR-5 LP2-11 LP2-19 LPCR-29 LPCR-35 LP3-39 LP3-37 LPCR-35 LP4-18 LPCR-35 LP2-23 LP4-21 LPCR-23 LP4-21 LPCR-23 LPCR-19 LP2-23 LP3-41 LP2-9 LPCR-6 LPCR-9 LP4-16 LP4-41 LPCR-9 LP4-16 LPCR-8 LP2-12 LP2-22 LP2-24 LPCR-14 LP4-16 LPCR-16 LPCR-16 LP4-25 LPCR-37 LP4-42 LP4-25 LP3-34 LP4-41 LPCR-5 LP3-33 LPCR-24 LPCR-26 LPCR-42 LP4-41 LPCR-5 LPCR-22 LPCR-35 LPCR-21 LP4-21 LPCR-21 LP4-21 LPCR-35 LP2-9 LP2-9 LP2-9 LPCR-17 LP2-23 LPCR-19 LP2-23 LPCR-17 LP3-25 LPCR-42 LP4-38 LPCR-8 LP4-36 LP4-34 LP4-32 LP 3 - 3 2 LP4-25 LPCR-39 LP4-25 LPCR-8 SCALE: 1/4"=1'-0" 2 ED1.2 ENLARGED DEMOLITION PLAN 1 1 1 1 2 2 2 LPCR-34 LPCR-32 LPCR-30 LPCR-28 LPCR-6 LP3-36 LPCR-40 LP3-40 LPCR-20 LP3-42 LPCR-20 LP3-38 LPCR-40 LPCR-40 SCALE: 1/4"=1'-0" 4 ED1.2 DEMOLITION PLAN ENLARGED 2 LPCR-18 LPCR-18 LPCR-2 LPCR-4 LP4-11 LPCR-12 LP4-11 LPCR-12 LP4-5 LP4-7 LP4-35 LP4-23 LP4-33 LPCR-4 LP4-9 LPCR-10 LP4-9 LPCR-10 LP4-9 LPCR-10 SCALE: 1/4"=1'-0" 3 ED1.2a DEMOLITION PLAN ENLARGED 2 ED1.2 ELECTRICAL POWER DEMOLITION PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 4 : 1 5 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 KEY NOTES GENERAL NOTES A. REFER TO SHEET E0.1 FOR LEGENDS, ABBREVIATIONS, AND GENERAL NOTES. 1 EXISTING SPACE TO REMAIN. NO WORK. 2 PROVIDE SELECTIVE ELECTRICAL DEMOLITION SERVICES FOR ALL ELECTRICAL SYSTEMS THROUGHOUT THE EXISTING SPACES THAT WILL BE RENOVATED UNDER THIS PROJECT (INCLUDING PANELBOARDS, FEEDERS, BRANCH CIRCUITING, CONDUIT, WIRING, DEVICES, ETC.). ALSO PROVIDE TEMPORARY CONSTRUCTION POWER AND LIGHTING AS REQUIRED. FIELD VERIFY ALL RELATED EXISTING CONDITIONS IN DETAIL PRIOR TO SUBMITTING A BID. EXISTING SYSTEMS / EQUIPMENT / LOCATIONS / CIRCUITING INFORMATION ON THIS DRAWING ARE FROM LANDLORDS AS-BUILT RECORD DOCUMENTS, AND ARE FOR REFERENCE USE. REFER TO F1 FIXTURE PLAN FOR ADDITIONAL STORE FIXTURE REQUIREMENTS. CONTRACTOR SHALL FIELD VERIFY ALL NECESSARY CIRCUITS FOR REUSE, PRIOR TO DEMOLITION. INFORMATION FROM OWNERS AS-BUILT DOCUMENTS ARE BELIEVED TO BE ACCURATE BUT CONTRACTOR MUST FIELD VERIFY ACCURACY PRIOR TO SUBMITTING BID. PROVIDE SELECTIVE DEMOLITION FOR AREAS REQUIRING EQUIPMENT REMOVAL FOR KROGER EQUIPMENT LAYOUTS. WHEN KROGER VACATES FACILITY UPON COMPLETION OF NEW STORE, EC IS RESPONSIBLE FOR RETURNING SPACE TO ORIGINAL PRECONSTRUCTION CONDITIONS. AM CB E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 E1.1 ELECTRICAL LIGHTING PLAN 4 2 2 2 2222 2 2 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 3 LP1-42 119 ACCT. 118 CUSTOMER SERVICE XXX CHECKLANES 100 SALES 109 BREAK ROOM 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 1'-6" 1'-6" 6' - 4 " 12 ' - 3 " 13 ' - 7 " 5' - 7 " 6' - 1 0 " 15 ' - 7 " 6' - 1 0 " 2'-1" 6'-2" D10 D11 1 S TYP 6 5 117 MEN 116 WOMEN 114 STORAGE 112 DATA 110 HALL "A" 115 HALL "B" 113 OFFICE 103 SEAFOOD PREP 104 MEAT PREP 102 PRODUCE PREP 101 HALL "C" 111 JANITOR'S CLOSET 21 3 C1 C1E C1 2 2'-7" 5' - 7 " E1.1 ELECTRICAL LIGHTING PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 2 : 5 7 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 KEY NOTES GENERAL NOTES 1. EXISTING TO REMAIN, UNLESS OTHERWISE NOTED. 2. RELOCATED LIGHT FIXTURE - WIRE INTO EXISTING NORMAL LIGHTING CIRCUIT. FIELD-VERIFY CIRCUIT AMPACITY BEFORE MODIFYING. IF CIRCUIT EXCEEDS 15 AMPS, NEW CIRCUITING WILL BE REQUIRED. 3. NEW LIGHT FIXTURE - WIRE INTO EXISTING NORMAL LIGHTING CIRCUIT. FIELD-VERIFY CIRCUIT AMPACITY BEFORE MODIFYING. IF CIRCUIT EXCEEDS 15 AMPS, NEW CIRCUITING WILL BE REQUIRED. 4. PROVIDE TIMER STYLE LIGHT SWITCH FOR FREEZER / COOLER. 5. FIXTURE WIRED AHEAD OF LOCAL LIGHT SWITCH, FIXTURE SHALL REMAIN CONSTANTLY ON. 6. MOUNT EMERGENCY LIGHTING BATTERY PACK ON EXTERIOR OF COOLER / FREEZER BOX. HEADS ARE TO BE REMOTE MOUNTING INSIDE BOX. LIGHTS SHALL TURN ON IN THE EVENT THAT THERE IS A LOSS OF BUILDING POWER. A. REFER TO SHEET E0.1 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. AM CB E 1 2 3 4 D C B A SY S T E M H SY S T E M H SY S T E M H SYSTEM H SYSTEM A SYSTEM B SYSTEM B SYSTEM C SYSTEM D SYSTEM F SYSTEM G SYSTEM E SYSTEM F SY S T E M E SCALE: 3/32"=1'-0" 1 E1.3 ELECTRICAL POWER PLAN P5D8HX M5DFR8HX M5DFR12HX M5DFR12HX M5DFR12HX DA5D12HX P5D12HX P5D8HX DA5D12HX M5DFR12HX P5D12HX P5D12HX P5D12HX P5D12HX P5D12HX P5D12HX F5DN8HX S204SC2 T4S T6D T6D T4D S36TR-8 DA 5 D 8 H X D A 5 D 8 H X DS 8 H E MS 8 H E MS 8 H E DS 1 2 H E G8 0 S C - 6 0 T8D T6D T4S GE216B GE186 D70V E102 E102 E15MK DA5D12HX GGDNIC8HI GGDNIC8HI GGDNLT12HI GGDNLT12HI AR E 6 6 AR E 6 6 AR E 6 6 AR E 6 6 AR E 6 6 AR E 6 6 (1 2 ) D A 2 - 2 8 L J J J J J J LP-SP LP-3 LP-1 MDP2 MDP LP-4 LP-2 LP-CR T6D LP4-34 LP4-4 LP4-6 LP 4 - 6 LP4-34 GGDITT10HI GGDITT12HI GGDITT10HI GG D N I C 6 P H I GG D N I C 6 P H I LP4-36 LP4-38 LP 4 - 3 6 LP4-32 LP4-38 LP4-38 LP 4 - 3 8 LP 4 - 9 LP 4 - 1 1 LP4-15 LP4-17 LP4-19 LP4-21 LP4-23 LP4-25 LP4-27 LP4-26 LP4-26 LP4-28 LP 4 - 2 8 LP2-19 LP2-21 LP2-23 LP2-25 LP2-27 LP2-29 LP2-31 LP2-33 LP2-9 LP2-11 LP2-16 LPCR-4 LP2-26 LP2-24 LP2-20 LP2-22 LPCR-1 LPCR-3 LPCR-5 LPCR-11 LPCR-9 LPCR-7 LPCR-15 LPCR-17 LPCR-2 9 10 10 ACORNVAC SYSTEM JDAC-55 LP4-2 DMHF4AM LP4-10,12 CHICKEN ROTISSERIE FIELD COORDINATE WIRING AND BREAKER SIZE WITH EQUIPMENT LPCR-20 LPCR-22 LPCR-24 LPCR-26 118 ACCT. 117 CUSTOMER SERVICE XXX CHECKLANES 100 SALES 117 MEN 116 WOMEN 114 STORAGE 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 104 MEAT PREP 102 PRODUCE PREP J DAC-55 LP4-2 J DAC-55 LP4-2 LP3- 39,41,43 ATS LP3 GENERATOR J LP4-40,42 40' REF TRAILER LP3-20,22,24 20' REF TRAILER LP3-32,34 20' REF TRAILER LP3-36,38 REFRIG SYSTEM A LP3-20,22,24 REFRIG SYSTEM B LP3-2,4,6 REFRIG SYSTEM C LP3-15,17,19 REFRIG SYSTEM D LP3-8,10,12 REFRIG SYSTEM E LP3-21,23,25 REFRIG SYSTEM F LP3-14,16,18 REFRIG SYSTEM G LP3-27,29,31 REFRIG SYSTEM H LP3-33,35,37 LPCR-21 LPCR-19 LPCR-17 EXTERIOR REFRIGERATION EQUIPMENT SHALL BE LOCATED UNDER DIRECTION OF KROGER PROJECT MANAGER. INTERIOR REFRIGERATION EQUIPMENT SHALL BE LOCATED UNDER DIRECTION OF KROGER PROJECT MANAGER. EQUIPMENT WILL BE MOUNTED ABOVE COOLER BOXES. 1 2 3 4 5 6 7 8 TYP FOR ALL FLOOR SALES EQUIPMENT J DOOR CONTROLLER (EXISTING) 11 12 M23 LP2-18 T4D LPCR-6 M115E LPCR-8 M115E LPCR-10 S24T S24T D23T D25 D23T D25 LPCR-12 LPCR-12 LPCR-12 POWER REEL LPCR-14 A1E J J J J J 13 GE38 GE38 GE102A 14 GWH-1 LPSP-36 J FAN COIL LP3-40 J FAN COIL LP3-40 J FAN COIL LP3-42 J FAN COIL LP3-42 J GENERATOR EPO 15 RX TRAILER LP3-26,28,30 101 HALL "C" 111 JANITOR'S CLOSET RC PANEL ABOVE COOLER LPSP-38 16 J JE9C E9K LPCR-35 E9S LPCR-33 J J J E9S LPCR-33 E9S LPCR-33 J FAN COIL LP3-40 E 1 2 3 4 D C B A J J J J J J J 13'-3" 49 ' - 2 " 14'-9" 5' - 3 " 118 ACCT. 117 CUSTOMER SERVICE XXX CHECKLANES 100 SALES 117 MEN 116 WOMEN 114 STORAGE 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 104 MEAT PREP 102 PRODUCE PREP J J J J 18'-2" 2' - 5 " 2'-4" 4'-0" 10 " 2' - 1 " 5' - 4 " 6' - 6 " 5' - 5 " 1' - 8 " 7' - 3 " 9' - 1 " 1' - 4 " 2' - 6 " 5' - 1 1 " 1' - 1 0 " 3' - 0 " 3' - 1 0 " 9' - 1 0 " 11 ' - 1 0 " SCALE: 3/32"=1'-0" 2 E1.3 ELECTRICAL POWER DIMENSION PLAN 5' - 7 " 5'-10" 2' - 3 " 1' - 1 1 " 4'-6" 3' - 5 " 2' - 4 " 3' - 1 0 " 5' - 6 " 1' - 4 " 19 ' - 5 " 2' - 0 " J J J J J J J J J J 101 HALL "C" 111 JANITOR'S CLOSET 1' - 1 0 " 3' - 3 " 2' - 0 " 6' - 1 0 " 3'-5" 11'-3" 14 ' - 6 " 29 ' - 2 " 2' - 5 " 8'-11" J J J J J J E1.3 ELECTRICAL POWER PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 2 : 1 9 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES A. REFER TO SHEET E0.1 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. AM CB KEY NOTES 1. EXISTING ELECTRICAL EQUIPMENT SHALL REMAIN. RE-CIRCUIT LOADS AS INDICATED ON UPDATED PANEL SCHEDULES. EXISTING CIRCUITS / WIRING SHALL BE REMOVED TO ACCOMMODATE EQUIPMENT LAYOUTS / REQUIREMENTS. PANEL LP-3 SHALL REMAIN (INACTIVE), BUT THE FEEDER TO THIS PANEL WILL BE UPDATED AND ROUTED TO THE NEW LP-3 LOCATION. 2. COORDINATE LOCATION OF AUTOMATIC TRANSFER SWITCH AND PANEL LP-3 WITH KROGER PM AND ALL OTHER TRADES. 3. REFRIGERATED TRAILERS SHALL BE LOCATED ADJACENT TO THE BUILDING. CONDUITS SHALL BE ROUTED OVERHEAD (OR ABOVE GRADE AND PROTECTED FROM DAMAGE). COORDINATE EXACT TERMINATION LOCATION WITH KROGER PM. 4. REFRIGERATION UNITS SHALL BE LOCATED ABOVE THE COOLER WALK-IN BOXES. THE ARRANGEMENT OF THE UNITS SHALL BE COORDINATED WITH THE KROGER PM AND REFRIGERATION ENGINEER. 5. COORDINATE LOCATION OF WASTEWATER VACUUM SYSTEM WITH KROGER PM AND PLUMBING CONTRACTOR. PROVIDE POWER FOR LOCAL CONTROL PANEL, PANEL SHALL BE FIELD LOCATED, POWER FROM PANEL LP-3. 6. AREA SHALL REMAIN, ELECTRICAL DEVICES SHALL REMAIN IN SERVICE AND BE LABELED IN EXISTING PANELBOARDS. 7. INSTALL OWNER PROVIDED POWER POLES FOR CHECKOUT LANES AND ASSOCIATED SALES FIXTURES. COORDINATE LOCATION OF POLES WITH KROGER PM. 8. ALL FLOOR SALES EQUIPMENT SHALL HAVE OVERHEAD FEEDS, COORDINATE LOCATION OF UTILITY DROPS WITH OTHER TRADES. 9. THE FOLLOWING APPLIES FOR ALL KITCHEN AND FOOD PREP TYPE AREAS. BEC SHALL PROVIDE GFCI RECEPTACLES FOR ALL 15A/120V AND 20A/120V RECEPTACLES. INSTALL ALL WALL POWER AND SYSTEMS OUTLETS RECESSED, FLUSH MOUNTED. INSTALL ALL WALL POWER AND SYSTEMS OUTLETS RECESSED, FLUSH MOUNTED. INSTALL ALL COUNTER HEIGHT POWER AND SYSTEM WALL OUTLETS HORIZONTALLY. CENTER THEM IN RESPECTIVE TILE OF THE BAND OF BULLNOSE WALL TILE THAT WILL BE INSTALLED. SEE ARCHITECTURAL DETAILS AND FIELD COORDINATE WITH TILE INSTALLER. DO NOT INSTALL POWER OR SYSTEMS OUTLETS WHERE WALL FINISH STYLES MEET - EITHER INSTALL FULLY IN BELOW THE BAND OF BULLNOSE TILE OR IN BULLNOSE WALL TILE AS DESCRIBED ABOVE. FEC TO PROVIDE ALL REQUIRED LOCAL DISCONNECTS FOR EQUIPMENT IN AREA PER NEC. 10. THE FOLLOWING APPLIES FOR PRODUCE PREP AND MEAT PREP. BEC SHALL PROVIDE WEATHERPROOF (RATED NEMA 3R WHILE-IN-USE) COVERS FOR ALL OUTLETS. PROVIDE GFCI RECEPTACLES FOR ALL 15A/120V AND 20A/120V RECEPTACLES. INSTALL ALL COUNTER HEIGHT POWER AND SYSTEM WALL OUTLETS HORIZONTALLY. SEE ARCHITECTURAL DETAILS AND FIELD COORDINATE WITH TILE INSTALLER. DO NOT INSTALL POWER OR SYSTEMS OUTLETS WHERE WALL FINISH STYLES MEET - EITHER INSTALL FULLY IN BELOW THE BAND OF BULLNOSE TILE OR IN BULLNOSE WALL TILE AS DESCRIBED ABOVE. 11. EXISTING DOOR CONTROLLER SHALL REMAIN, IDENTIFY WIRING / CIRCUIT IN PANELBOARD AND UPDATE SCHEDULE. 12. PROVIDE 6" CONCRETE PAD FOR GENERATOR, PAD TO EXTEND 4" OUTSIDE OF ENCLOSURE. CONDUITS SHALL BE ROUTED OVERHEAD (OR ABOVE GRADE AND PROTECTED FROM DAMAGE). COORDINATE EXACT TERMINATION LOCATION WITH KROGER PM 13. BEC SHALL INSTALL OWNER-FURNISHED CORD REEL FOR DISPLAY POWER DROPS. SEE SPECIFICATION SECTION 26 05 33 FOR MORE DETAILS. COORDINATE FINAL LOCATION WITH KROGER PROJECT MANAGER PRIOR TO ROUTING CONDUIT / WIRING. 14. PANEL LP3 TO BE DE-ENERGIZED AND ROOF TOP SERVICE RECEPTACLE CIRCUITS TO BE RELOCATED TO PANEL LPSP. 15. BEC SHALL PROVIDE GENERATOR EMERGENCY POWER OFF (EPO). FIELD WIRE EPO SWITCH INSIDE BUILDING NEAR EGRESS DOOR AS SHOWN ON DRAWING FOR EMERGENCY SHUTOFF OF GENERATOR LOCATED OUTSIDE. SEE SINGLE LINE DIAGRAM FOR MORE DETAIL. 16. COORDINATE LOCATION WITH ENERGY MANAGEMENT CONTRACTOR. E5.1 ELECTRICAL DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 3 : 1 8 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 AM CB 7 TO TELEPHONE TERMINAL BOARD 6 54 10 2 11 DESIGN CALCULATED LOAD 3 100 A OVERCURRENT PROTECTION DEVICE 2 1 4 5 3 4 #1 + 1#6IG - 1-1/2"C 8 10 11 9 6 9 "MDP" MAIN DISTRIBUTION PANELBOARD SPD NEUTRAL BUS GROUND BUS REMOVABLE LINK TO UNDERGROUND UTILITY SERVICE 1 7 FIELD MEASURED LOADS AØ BØ CØ CONDUIT & FEEDER SIZE FEEDER RTU-1 RTU-2 RTU-3 WP WP WP MDP MDP MDP RTU-3 RTU-2 RTU-1 LP-4 LP-2 LP-1 LP-SP LP-CR (SEE NOTE 3) SCALE: N.T.S. 1 E-510 FEEDER DIAGRAM 208Y/120V,3Ø,4W, MAIN SERVICE NO. M 4#1/0 - 2"C 150 A 150 A (2) SETS OF (4) 250kcmil AL & (1) #1 AL GROUND IN 3 INCH CONDUIT (EACH) 400 A 4#1/0 + 1#6G - 2"C 150A 100 A 3#6 - 1"C 60 A 60 A 3#10 - 3/4"C 25 A 2 SETS 4#500 KCMIL - (2) 3-1/2"C 800 A 3#12 + 1#12G-3/4"C 20 A 8 CU-1 WP MDP CU-2 28360 VA 40485 VA 40380 VA 54720 VA 30400 VA 40226 VA 4323 VA 18000 VA 18000 VA 6500 VA 285717 VA 4#1/0 - 2"C 4 #1 - 1-1/2"C 3#6 - 1"C 12 3#12 + 1#12G-3/4"C 15 A 4323 VA 12 CU-2 WP MDP CU-1 EX EX EX EX EX EX EX EX EX EX EX EX LP-3 EX 1 1 1 1 1 2 2 3 3 1 4 4 4 4 4 6 E6.2 ELECTRICAL SINGLE LINE DIAGRAM AND SCHEDULES FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 3 : 2 3 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 SINGLE LINE KEY NOTES 1 EXISTING PANELBOARDS SHALL REMAIN, AND BE RE-CIRCUITED AS REQUIRED TO POWER EQUIPMENT. PROVIDE NEW BRANCH BREAKERS, TO MATCH EXISTING, FOR NEW BRANCH CIRCUIT WORK SHOWN ON DRAWINGS AS APPLICABLE. REWORK POSITIONING OF EXISTING BRANCH BREAKERS AS / IF REQUIRED TO ACCOMMODATE NEW MULTI-POLE BREAKERS IF APPLICABLE. COMBINE EXISTING LIGHTLY LOADED CIRCUITS IF REQUIRED FOR SAME. RE-LABEL AND RE-COLOR CODE RELATED CONDUCTORS, ETC. IF REQUIRED. X PROVIDE NEW TYPEWRITTEN PANELBOARD DIRECTORY/SCHEDULE AT THE END OF EACH CONSTRUCTION PHASE, SHOWING ACCURATE DESCRIPTIONS THAT REFLECT NEW WORK AND REMOVED WORK. 2 ROUTE NEW FEEDER TO PANEL LP-3 VIA TRANSFER SWITCH, AS SHOWN ON GENERATOR SINGLE LINE DIAGRAM. REFER TO PLAN VIEW FOR LOCATIONS OF EQUIPMENT. EXISTING PANEL LP-3 SHALL REMAIN IN PLACE. BUT BE OUT OF SERVICE. ANY CIRCUITS THAT NEED TO REAMIN SHOULD BE REFED FROM ADJACENT PANELS. 3 EXISTING LIGHTING CONTACTORS TO REMAIN AND BE MODIFIED AS REQUIRED, FIELD VERIFY OPERATION AND DEMONSTRAT SYSTEM FUNCTION TO KROGER PM. 4 EXISTING RTU AND CU UNITS SHALL REMAIN IN SERVICE. 5 PROVIDE CONCRETE EQUIPMENT PAD FOR EXTERIOR GENERATOR. 6 PROVIDE 400 AMP FUSIBLE SWITCH IN MAIN DISTRIBUTION BOARD. SINGLE LINE LEGEND A. FEEDERS DENOTED BY A "*" HAVE BEEN OVERSIZED TO COMPENSATE FOR VOLTAGE DROP. B. "CU" = COPPER CONDUCTOR C. "AL" = ALUMINUM CONDUCTOR D. "EX" = EXISTING CONDUIT / WIRING E. IF ALUMINUM CONDUCTORS ARE USED FOR ANY FEEDER AND LUGS/TRANSFORMER COMPARTMENT DO NOT ALLOW THE INCREASED SIZE, COPPER CONDUCTORS SHALL BE INSTALLED. GENERAL NOTES- FEEDER SCHEDULE GENERAL SINGLE-LINE/RISER NOTES A. EXISTING CONDITIONS REFLECT BEST AVAILABLE INFORMATION. REMOVE INDICATED ELECTRICAL EQUIPMENT, FEEDERS AND OTHER RELATED MATERIALS DURING THE DEMOLITION PERIOD OF THE RESPECTIVE CONSTRUCTION PHASE. B. PARALLEL FEEDER CONDUCTORS SHALL BE CUT TO EXACTLY THE SAME LENGTHS AND SHALL BE FROM THE SAME FACTORY RUN. ALL CONNECTIONS FOR SAME SHALL BE TORQUED TO IDENTICAL VALUES. C. EXTERIOR ELECTRICAL WORK SHALL NOT ONLY BE WEATHERPROOF AND WATER-TIGHT, BUT SHALL ALSO BE RUST-RESISTANT. D. CONDUCTORS BELOW GRADE OR SUBJECT TO MOISTURE SHALL BE "XHHW-2". E. PROVIDE FACTORY SERIES COORDINATION FOR LIFE SAFETY CIRCUIT BREAKERS (INCLUDING ALL BRANCH BREAKERS), RELATIVE TO "UPSTREAM" BREAKERS, SO THAT ONLY THE BREAKER CLOSEST IN THE CIRCUIT TO THE LOAD TRIPS UPON AN OVERLOAD OR FAULT CONDITION. F. POWER DISTRIBUTION EQUIPMENT SUPPLIER SHALL PROVIDE EQUIPMENT APPROPRIATELY RATED AND BRACED TO ACCOMMODATE THE AVAILABLE FAULT CURRENT AT THE UTILITY COMPANY TRANSFORMER SECONDARIES. THIS SUPPLIER SHALL ACCORDINGLY PROVIDE ANY RELATED CALCULATIONS SO THAT THEIR EQUIPMENT IS PROPERLY COORDINATED FOR THE AVAILABLE FAULT CURRENT. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THIS SUPPLIER WITH COPIES OF THE ELECTRICAL DOCUMENTS AS REQUIRED SO THAT PROPERLY RATED/BRACED EQUIPMENT IS PROVIDED UNDER BASE BID. G. ALL SWITCHBOARD DISTRIBUTION MAIN SWITCH FUSES SHALL BE EQUAL TO BUSSMAN 3OW-PEAK, DUAL-ELEMENT, TIME-DELAY, CLASS RK1. ALL SWITCHBOARD DISTRIBUTION FUSES SHALL BE EQUAL TO BUSSMAN LOW-PEAK, DUAL-ELEMENT, TIME-DELAY, CLASS RK-1. IN ADDITION TO PROVIDING ALL REQUIRED NEW FUSES, REPLACE ALL EXISTING FUSES THAT DO NOT CURRENTLY MEET FUSE SPECIFICATIONS (SUCH REPLACEMENT FUSES WILL BE FURNISHED BY KROGER). H. UNLESS SPECIFICALLY SHOWN OTHERWISE ON THE SINGLE-LINE DIAGRAM, THE AVAILABLE FAULT CURRENT AT ALL NEW POWER DISTRIBUTION EQUIPMENT IS LESS THAN 10,000 AMPERES. I. PROVIDE GROUNDING ELECTRODE CONDUCTORS PER THE PROVISIONS OF THE NEC, NEC ARTICLE 250, AND TABLE 250-66. J. PROVIDE EQUIPMENT GROUNDING CONDUCTORS PER THE PROVISIONS OF THE NEC, NEC ARTICLE 250, AND TABLE 250-122. K. WORKING CLEARANCES SHALL BE PROVIDED FOR ALL ELECTRICAL EQUIPMENT (SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, STARTERS, DISCONNECTS, ETC. AS APPLICABLE) IN STRICT COMPLIANCE WITH THE NEC AND NEC CHAPTER 1, PART B, SECTION 110-26(a). LOCATIONS SHOWN ON FLOOR PLANS ARE SCHEMATIC AND DIAGRAMMATIC IN NATURE. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COMPLIANCE WITH THE ABOVE N.E.C. REFERENCE. THIS REQUIREMENT APPLIES TO EQUIPMENT ON FLOOR PLANS, EQUIPMENT SHOWN ON RISER, EQUIPMENT FURNISHED BY THE OWNER OR OTHER CONTRACTORS, AND EQUIPMENT FURNISHED BY THE ELECTRICAL CONTRACTOR. L. EXISTING EQUIPMENT / PANELBOARD SHALL REMAIN (OR BE RELOCATED OR REPLACED IF SO INDICATED). PROVIDE NEW BRANCH BREAKERS, TO MATCH EXISTING, FOR NEW BRANCH CIRCUIT WORK SHOWN ON DRAWINGS AS APPLICABLE. REWORK POSITIONING OF EXISTING BRANCH BREAKERS AS / IF REQUIRED TO ACCOMMODATE NEW MULTI-POLE BREAKERS IF APPLICABLE. COMBINE EXISTING LIGHTLY LOADED CIRCUITS IF REQUIRED FOR SAME. RE-LABEL AND RE-COLOR CODE RELATED CONDUCTORS, ETC. IF REQUIRED. REMOVE ALL ABANDONED BRANCH CIRCUIT WIRING AND CONDUIT FOR ALL PREVIOUSLY ABANDONED / REMOVED LOADS AND FOR ALL LOADS THAT WILL BE ABANDONED / DEMOLISHED / REMOVED UNDER THIS PROJECT. FIELD VERIFY ALL SPECIFICS. PROVIDE NEW TYPEWRITTEN PANELBOARD DIRECTORY / SCHEDULE AT THE END OF EACH CONSTRUCTION PHASE, SHOWING ACCURATE DESCRIPTIONS THAT REFLECT NEW WORK AND REMOVED WORK . M. HOLD ALL NEW OVERHEAD ELECTRICAL WORK AS TIGHT AS POSSIBLE TO THE BOTTOM OF THE OVERHEAD STRUCTURE. LOCATE ANY RELATED PULLBOXES SO THAT THEY WILL BE FULLY ACCESSIBLE AFTER ALL CONSTRUCTION WORK IS COMPLETE. AS WITH ALL WORK, COORDINATE IN ADVANCE WITH ALL OTHER TRADES. N. PROVIDE NEW BRANCH BREAKERS, TO RESPECTIVELY MATCH EXISTING, AS APPLICABLE AT ALL EXISTING PANELBOARDS THROUGHOUT THAT SERVE NEW BRANCH CIRCUIT HOME-RUNS. REWORK POSITIONING OF EXISTING BRANCH BREAKERS IF REQUIRED TO ACCOMMODATE NEW MULTI-POLE BREAKERS. COMBINE EXISTING LIGHTLY LOADED CIRCUITS IF REQUIRED FOR SAME. RE-LABEL AND RE-COLOR CODE RELATED CONDUCTORS, ETC. IF REQUIRED. O. ALL PANELS HAVE NEMA 1 ENCLOSURES UNLESS OTHERWISE NOTED. P. ALL PANEL ARE SURFACE MOUNTED UNLESS OTHERWISE NOTED. CM CB K100-NG-OD-120/208 GENERAC, OUTDOOR STANDBY GENERATOR, 120/208 VAC 3 PHASE, NATURAL GAS, 100 KW RATING, ENCLOSURE - STANDARD - STEEL, BLOCK HEATER 1500W, NO MAIN LINE CIRCUIT BREAKER (MLCB), BUS BARS ONLY, LH, 100DBA ALARM HORN, REMOTE EMERGENCY STOP BREAK GLASS EPA CERTIFIED, INDUSTRIAL GREY ENCLOSURE, INSTALLATION NOT INCLUDED. PRICE INCLUDES FACTORY STARTUP ONLY. ATS SOLD SEPARATELY. K-0046624 HTSN400G1 ATS, 400 AMP, 120/208V, 3 POLE, NEMA 1 ENCLOSURE MODEL HTSN400G1 K-0007901 LUMINAIRE SCHEDULE FIXTURE TYPE EPRO ITEM # FIXTURE DESCRIPTION MANUFACTURER OSRAM SYLVANIA LAMP # OF LAMPS / FIXTURE OSRAM SYLVANIA LAMP PART # OSRAM SYLVANIA LAMP EPRO K # OSRAM SYLVANIA BALLAST SPECIFICATION # OF BALLASTS / FIXTURE OSRAM SYLVANIA BALLAST PART # OSRAM SYLVANIA BALLAST EPRO K # SYSTEM WATTAGE C1 K-0008205 RECESSED 2'X4' W/ (3) T8 LAMPS & (1) INSTANT START BALLAST, PRISMATIC LENS W/ NO REVEAL, GRID CEILING. COOPER (METALUX) 2GR8-332A-UNV-QHE3X32ISNSC FO28/835/XP/SS/ECO 3 22178 K-0037162 QHE 3X32T8/UNV ISN-SC 1 49970 K-0002521 72 C1E K-0008376 EMERGENCY RECESSED 2'X4' W/ (3) T8 LAMPS & (1) INSTANT START BALLAST, 18-CELL SPECUALR W/ BLACK REVEAL, GRID CEILING. COOPER (METALUX) 2GR8-332A-120-EL-I320-QHE3X32ISNSC FO28/835/XP/SS/ECO 3 22178 K-0037162 QHE 3X32T8/UNV ISN-SC 1 49970 K-0002521 72 D10 K-0019133 8'-0" (2) T8 LAMP STRIP FLUORESCENT W/ (1) PROSTART BALLAST. COOPER (METALUX) 8TSSF-232-UNV-QHE4X32PSNSC FO28/835/XP/SS/ECO 4 22178 K-0037162 QHE 4X32T8/UNV PSN-SC 1 51418 K# not yet assigned 98 D11 K-0019134 4'-0" (2) T8 LAMP STRIP FLUORESCENT W/ (1) PROSTART START BALLAST. COOPER (METALUX) SSF-232-UNV-QHE2X32PSNTC FO28/835/XP/SS/ECO 2 22178 K-0037162 QHE 2X32T8/UNV PSN-MC 1 51408 K-0020399 51 EM K-0008360 EMERGENCY LIGHT W/ (2) PAR36 TYPE LAMP HEADS. COOPER (SURELITES) CC4WH-NONHEAD AND 6T6DWWH (MOUNT BATTERY UNIT OUTSIDE COOLER BOX AND REMOTE HEADS ON INTERIOR OF COOLER BOX) MR16 LAMP 6V 9W LAMPS INCLUDED 2 9 M6 K-0019146 8'-0" (2) T8 LAMP VAPORTIGHT W/ INTERNAL PRISMATIC LENS, STAINLESS STEEL LATCHES, WET LABEL, TOP MOUNT CONDUIT & (1) PROSTART BALLAST. COOPER (METALUX) 8TVT2-232DR-UNV-QHE4X32PSNSC-WL-TH -SSL FO30/835/XP/SS/ECO 4 22060 K-0002502 QHE 4X32T8/UNV PSN-SC 1 51418 K# not yet assigned 103 M6E K-0038957 8'-0" (2) T8 LAMP VAPORTIGHT W/INTERNAL PRISMATIC LENS. STAINLESS STEEL LATCHES, WET BABEL, TOP MOUNT CONDUIT & (1) PROSTART BALLAST. EMERGENCY FIXTURE. COOPER (METALUX) 8TVT2-232-DR-120-EL-I232DL-QHE4X32PSNSC-WL-TH-SSL FO30/835/XP/SS/ECO 4 22060 K-0002502 QHE 4X32T8/UNV PSN-SC 1 51418 K# not yet assigned 103 M7 K-0019147 4'-0" (2) T8 LAMP VAPORTIGHT WITH INTERNAL PRISMATIC LENS, STAINLESS STEEL LATCHES, WET LABEL, TOP MOUNT CONDUIT & (1) PROSTART BALLAST. COOPER (METALUX) VT2-232DR-UNV-QHE2X32PSNMC-WL-TH -SSL FO30/835/XP/SS/ECO 2 22060 K-0002502 QHE 2X32T8/UNV PSN-MC 1 51408 K-0020399 53 M13 K-0021076 2 FT VAPOR TIGHT LED LIGHT FIXTURE - 4100K COOPER VT-LD2-30DR-UNV-L840-CD1-WL-U LEDs INCLUDED 36 MOTION SENSORS / POWER PACKS / SWITCHES TS1 K-0019120 TIMER SWITCH COOPER (GREENGATE) TSW-MV MS1 K-0019122 OCCUPANCY SWITCH, SINGLE LOAD WATTSTOPPER OS P/N PW-100 MECHANICAL - PLUMBING - ELECTRICAL COORDINATION SCHEDULE Project: KROGER J959 CARMEL, IN (EXPRESS) Design: BRANSCUM Comm No: 515013 Checked: BRANSCUM MECHANICAL-PLUMBING-ELECTRICAL COORDINATION SCHEDULE GAS POWER DISCONNECT MOTOR CONTROL CONTROL NOTES MARK DESCRIPTION LOCATION MBH VOLTS PH HP kW FLA MCA MOCP FURN INST WIRE TYPE FURN INST WIRE TYPE FURN INST WIRE HVAC EQUIPMENT HVAC EQUIPMENT - TO BE ABANDON IN PLACE AC-1 MINI SPLIT SYSTEM WALL CU-1 CONDENSING UNIT ROOF CU-3 CONDENSING UNIT ROOF EF-3 EXHAUST FAN HVAC EQUIPMENT - EXISTING TO REMAIN RTU-1 ROOFTOP UNIT ROOF RTU--2 ROOFTOP UNIT ROOF RTU-3 ROOFTOP UNIT ROOF EH-1 ELEC. HEATER WALL GUH-1 UNIT HEATER GUH-2 UNIT HEATER EF-1 EXHAUST FAN EF-2 EXHAUST FAN EF-2 EXHAUST FAN SF-1 SUPPLY FAN ROOF EWH ELEC. HEATER WALL EWH ELEC. HEATER WALL EWH ELEC. HEATER WALL PLUMBING EQUIPMENT AND FIXTURES GWH-1 WATER HEATER (GAS) ABOVE SEAFOOD PREP 199 120 1 EC EC EC NA MFR MFR MFR LOW EC EC EC ELECTRIC SPARK IGNITION AC-1 ACORNVAC SYSTEM BACK ROOM 208 3 (2) 2 EC EC EC MFR MFR EC EC LINE EC EC EC CB CIRCUIT BREAKER CS COMBINATION STARTER CC CONTROLS CONTRACTOR MCC MOTOR CONTROL CENTER CN CONTROL MG MAGNETIC STARTER OR CONTACT DB DIRECT BUY MS MANUAL STARTER DC DISCONNECT MSR MANUAL STARTER WITH CONTROL RELAY EC ELECTRICAL CONTRACTOR OV OVERCURRENT PROTECTION EM EQUIPMENT MANUFACTURER VFD VARIABLE FREQUENCY DRIVE EX EXISTING FAC FIRE ALARM CONTRACTOR FLA FULL LOAD AMP BAS BUILDING AUTOMATION SYSTEM FPC FIRE PROTECTION CONTRACTOR CPT CONTROL POWER TRANSFORMER FURN FURNISH EMS ENERGY MANAGEMENT SYSTEM FUSE FUSE FA FIRE ALARM GC GENERAL CONTRACTOR LINE LINE VOLTAGE CONTROLS INST INSTALL LOW LOW VOLTAGE CONTROLS OR OWNER MAN MANUAL MC MECHANICAL CONTRACTOR MC MOTOR CONTROL MFR MANUFACTURER TC TIME CLOCK E6.2.1 ELECTRICAL PANEL SCHEDULES FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 3 : 3 4 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 LP1 LP2 LP3 PANEL SCHEDULE LEGEND LP4 LPCR LPSP - - MDP AM CB PANEL: LP1 (EXISTING) 120/208V, 3PH, 4W LOCATION: ELECTRICAL ROOM 225 AMP MLO SUPPLY FROM: MDL 10,000 AIC (MINIMUM) MOUNTING: SURFACE LOAD IN KVA PER PHASE CKT DESCRIPTION BKR PL A B C PL BKR DESCRIPTION CKT 1 EX-LIGHTING CONTACTOR A 0.00 1.40 1 20 EX-OFFICE LIGHTS 2 3 0.00 0.00 1 20 EX-SPARE 4 5 0.00 1.20 1 20 EX-STORE ROOM LIGHTS 6 7 EX-REAR DOORBELL 20 1 0.10 0.00 EX-LIGHTING CONTACTOR B 8 9 EX-FIRE BELL 20 1 0.10 0.00 10 11 EX-REAR EXIT/ SECURITY LIGHTS 20 1 0.60 0.00 12 13 EX-EXIT SIGNS 20 1 0.50 0.98 1 20 EX-RX LIGHTS 14 15 EX-EM/ LIGHTS 20 1 1.20 0.70 1 20 EX-RX LIGHTS 16 17 EX-CONTACTOS BY-PASS 20 1 0.50 1.18 1 20 EX-RX TAKE CARE LIGHTS 18 SPLIT BUS SEPARATION 19 EX-FRONT SALES LIGHTS ROW 2 20 1 1.48 1.48 1 20 EX-WEST SOFFIT 20 21 EX-FRONT SALES LIGHTS ROW 3 20 1 1.48 0.00 1 20 EX-SPARE 22 23 EX-COSMETICS RECEPTACLE 20 1 0.00 1.48 1 20 EX-FRONT SALES LIGHTS ROW 1 24 SPLIT BUS SEPARATION 25 EX-REAR SALES LIGHTS 20 1 1.42 1.40 1 20 EX-REAR SALES LIGHTS ROW 12 26 27 EX-REAR SALES LIGHTS 20 1 1.13 1.20 1 20 EX-REAR SALES LIGHTS ROW 10 28 29 EX-REAR SALES LIGHTS 20 1 1.00 0.70 1 20 EX-GONDOLAS E & N 30 31 EX-SALES LIGHTS S ROW 20 1 1.11 1.48 1 20 EX-REAR SALES LIGHTS ROW 11 32 33 EX-PLUGMOLD/ GONDOLA LIGHTS 20 1 0.86 1.48 1 20 EX-REAR SALES LIGHTS 34 35 EX-FUJI PHOTO PROC. 20 1 1.11 1.48 1 20 EX-REAR SALES LIGHTS 36 37 EX-FUJI PHOTO PROC. 20 1 1.48 1.18 1 20 EX-REAR SALES LIGHTS 38 39 EX-REAR SALES LIGHTS 20 1 1.11 1.30 1 20 EX-REAR SALES LIGHTS 40 41 EX-REAR SALES LIGHTS 20 1 1.48 0.72 1 20 COOLER/ PREP ROOM LIGHTS 42 TOTAL PER PHASE: 14.00 10.55 11.45 KVA TOTAL CONNECTED LOAD: 36.00 KVA 99.99 AMPS FEEDER DEMAND LOAD: 36.00 KVA 99.99 AMPS PROVIDE SWITCHING DUTY CIRCUIT BREAKERS FOR LIGHTING CIRCUITS CONTROLLED FROM BREAKER PROVIDE HACR CIRCUIT BREAKERS FOR HVAC AND REFRIGERATION EQUIPMENT ABBREVIATIONS: # (GF) = GROUND FAULT INTERRUPTER, (ST) = SHUNT TRIP, (LO) = LOCK-ON, (IG) = ISOLATED GROUND, (HL)=HAND LOCK *** (GFE) = GROUND FAULT INTERRUPTER FOR EQUIPMENT EX - IN DESCRIPTION INDICATES EXISTING LOAD N - NEW CIRCUIT BREAKER, RETAIN EXISTING BREAKERS FOR RE-USE PANEL: LP2 (EXISTING) 120/208V, 3PH, 4W LOCATION: ELECTRICAL ROOM 225 AMP MLO SUPPLY FROM: MDL 10,000 AIC (MINIMUM) MOUNTING: SURFACE LOAD IN KVA PER PHASE CKT DESCRIPTION BKR PL A B C PL BKR DESCRIPTION CKT 1 EX-GEN. SALES RECEPTACLE 20 1 0.18 0.60 1 20 EX-FRONT SLIDING DOOR 2 3 EX-SPARE 20 1 0.00 0.18 1 20 EX-ELECTRONIC ARTICLE SURV. 4 5 EX-UNIT HEATER/ EXHAUST FAN 20 1 0.15 1.50 1 20 EX-WOMENS HAND DRYER 6 7 EX-SPARE 20 1 0.00 1.50 1 20 EX-WATER COOLER 8 9 TABLE RECEPTACLE - MEAT/ SEAFOOD 20 1 0.80 1.50 1 20 EX-MENS HAND DRYER 10 11 TABLE RECEPTACLE - MEAT/ SEAFOOD 20 1 0.80 0.00 1 20 SPARE 12 13 EX-BREAK ROOM 20 1 0.18 0.30 1 20 EX-DIEBOLD 14 15 EX-BREAK ROOM 20 1 0.18 0.70 1 20 REMOVE ICE FLAKER - SEAFOOD 16 17 EX-EXISTING CIRCUIT 20 1 0.00 1.02 1 20 WRAP AND WEIGH - MEAT PREP 18 19 COMPUTERS - OFFICE 20 1 0.11 0.80 1 20 TABLE RECEPTACLE - PRODUCE PREP 20 21 REFRIGERATOR - BREAKROOM 20 1 0.80 0.80 1 20 TABLE RECEPTACLE - PRODUCE PREP 22 23 MICROWAVE - BREAKROOM 20 1 1.68 1.33 1 20 ICE MERCHANDISER 24 25 COFFEE MACHINE - BREAKROOM 20 1 1.44 0.13 1 20 ICE MERCHANDISER EVAPORATOR 26 27 SEAFOOD STORAGE FREEZER - BACKROOM 20 1 1.79 0.00 1 20 EXISTING CIRCUIT 28 29 TABLE RECEPTACLE - DELI PREP 20 1 0.80 0.50 2 20 EX-RESTROOM WALL HEATER 30 31 TABLE RECEPTACLE - DELI PREP 20 1 0.80 0.50 32 33 TABLE RECEPTACLE - DELI PREP 20 1 0.80 0.75 2 20 EX-RENZOR ROOF UNIT 34 35 SPARE 20 1 0.00 0.75 36 37 EX-HEATER/ EXHAUST - STOCKROOM 20 1 0.25 0.00 1 20 SPARE 38 39 0.25 0.50 2 20 EX-REAR HALL HEATER 40 41 0.25 0.50 42 TOTAL PER PHASE: 6.79 9.04 9.28 KVA TOTAL CONNECTED LOAD: 25.12 KVA 69.77 AMPS FEEDER DEMAND LOAD: 17.56 KVA 48.77 AMPS PROVIDE SWITCHING DUTY CIRCUIT BREAKERS FOR LIGHTING CIRCUITS CONTROLLED FROM BREAKER PROVIDE HACR CIRCUIT BREAKERS FOR HVAC AND REFRIGERATION EQUIPMENT ABBREVIATIONS: # (GF) = GROUND FAULT INTERRUPTER, (ST) = SHUNT TRIP, (LO) = LOCK-ON, (IG) = ISOLATED GROUND, (HL)=HAND LOCK *** (GFE) = GROUND FAULT INTERRUPTER FOR EQUIPMENT EX - IN DESCRIPTION INDICATES EXISTING LOAD N - NEW CIRCUIT BREAKER, RETAIN EXISTING BREAKERS FOR RE-USE PANEL: LP3 (NEW) 120/208V, 3PH, 4W LOCATION: ELECTRICAL ROOM 400 AMP MLO SUPPLY FROM: MDL 42,000 AIC (MINIMUM) MOUNTING: SURFACE LOAD IN KVA PER PHASE CKT DESCRIPTION BKR PL A B C PL BKR DESCRIPTION CKT 1 SPARE 20 1 0.00 4.19 3 60 THSD751-502S SYSTEM B REFRIGERATION 2 3 SPARE 20 1 0.00 4.19 4 5 SPARE 20 1 0.00 4.19 6 7 SPARE 20 1 0.00 4.19 3 60 THSD751-502S SYSTEM D REFRIGERATION 8 9 THSD751-502S SYSTEM A REFRIGERATION 60 3 4.19 4.19 10 11 4.19 4.19 12 13 4.19 3.48 3 45 HICA0734PLKHD SYSTEM F REFRIGERATION 14 15 THSD751-502S SYSTEM C REFRIGERATION 60 3 4.19 3.48 16 17 4.19 3.48 18 19 4.19 2.40 3 50 40' REFRIGERATED CONTAINER 20 21 HICA0494PSKGF SYSTEM E REFRIGERATION 35 3 2.40 2.40 22 23 2.40 2.40 24 25 2.40 4.20 3 100 PHARMACY 26 27 HICA0326PLKDE SYSTEM G REFRIGERATION 20 3 1.44 4.20 28 29 1.44 4.20 30 31 1.44 1.25 2 30 20' REFRIGERATED CONTAINER 32 33 HICA0494PSKHF SYSTEM H REFRIGERATION 35 3 2.40 1.25 34 35 2.40 1.25 2 30 20' REFRIGERATED CONTAINER 36 37 2.40 1.25 38 39 ACORN VACUUM SYSTEM 30 3 0.96 0.90 1 20 FAN COILS - PREP AREAS 40 41 0.96 0.90 1 20 FAN COILS - DAIRY COOLER 42 43 0.96 0.00 1 20 SPARE 44 45 VACUUM SYSTEM CONTROL PANEL 20 1 0.18 0.00 1 20 SPARE 46 47 SPARE 20 1 0.00 0.00 1 20 SPARE 48 TOTAL PER PHASE: 36.54 36.37 36.19 KVA TOTAL CONNECTED LOAD: 109.11 KVA 303.08 AMPS FEEDER DEMAND LOAD: 109.11 KVA 303.08 AMPS PROVIDE SWITCHING DUTY CIRCUIT BREAKERS FOR LIGHTING CIRCUITS CONTROLLED FROM BREAKER PROVIDE HACR CIRCUIT BREAKERS FOR HVAC AND REFRIGERATION EQUIPMENT ABBREVIATIONS: # (GF) = GROUND FAULT INTERRUPTER, (ST) = SHUNT TRIP, (LO) = LOCK-ON, (IG) = ISOLATED GROUND, (HL)=HAND LOCK *** (GFE) = GROUND FAULT INTERRUPTER FOR EQUIPMENT EX - IN DESCRIPTION INDICATES EXISTING LOAD N - NEW CIRCUIT BREAKER, RETAIN EXISTING BREAKERS FOR RE-USE R - RELOCATED CIRCUIT FROM PREVIOUS LP3 PANEL PANEL: LP4 (EXISTING) 120/208V, 3PH, 4W LOCATION: ELECTRICAL ROOM 225 AMP MLO SUPPLY FROM: MDL 10,000 AIC (MINIMUM) MOUNTING: SURFACE LOAD IN KVA PER PHASE CKT DESCRIPTION BKR PL A B C PL BKR DESCRIPTION CKT 1 SPARE 20 1 0.00 0.10 1 20 COOLER DOOR SENSOR 2 3 EX-CU-3 20 1 0.60 1.26 1 20 CASE LIGHTS 4 5 20 1 0.60 1.42 1 20 CASE LIGHTS 6 7 EX-GP TANS HUB 20 1 0.00 0.18 1 20 EX-RECEIVING RECEPTACLE 8 9 CASE ANTI SWEATS 20 1 1.20 1.50 2 50 CHICKEN ROTISSERIE 10 N 11 CASE ANTI SWEATS 20 1 0.80 1.50 12 13 EX-EXAM WATER HEATER 20 1 0.00 0.00 1 20 SPARE 14 15 CASE ANTI SWEATS 20 1 0.72 0.00 1 20 EXISTING CIRCUIT 16 17 CASE ANTI SWEATS 20 1 1.37 0.00 1 20 EX-SPARE 18 19 CASE ANTI SWEATS 20 1 0.74 0.50 1 20 EX-EXAM ROOM HEATER 20 21 CASE ANTI SWEATS 20 1 0.98 0.50 1 20 EX-EXAM ROOM HEATER 22 23 CASE ANTI SWEATS 20 1 0.70 0.00 1 20 SPARE 24 25 CASE ANTI SWEATS 20 1 0.70 1.66 1 20 CASE FANS 26 27 CASE ANTI SWEATS 20 1 0.84 1.08 1 20 CASE FANS 28 29 EX-GP TANS HUB 20 1 0.00 0.00 1 20 SPARE 30 31 CASE ANTI SWEATS 20 1 0.00 0.96 1 20 CASE LIGHTS 32 33 CASE ANTI SWEATS 20 1 0.00 1.44 1 20 CASE LIGHTS 34 35 CASE ANTI SWEATS 20 1 0.00 0.93 1 20 CASE LIGHTS 36 37 EX-OFFICE/ STOCK ROOM HEATER 20 1 0.50 1.50 1 20 CASE FANS 38 39 20 1 0.50 0.20 1 20 GENERATOR BATTERY CHARGER 40 41 SPARE 20 1 0.00 1.50 1 20 GENERATOR BLOCK HEATER 42 TOTAL PER PHASE: 6.83 10.81 8.82 KVA TOTAL CONNECTED LOAD: 26.46 KVA 73.49 AMPS FEEDER DEMAND LOAD: 26.46 KVA 73.49 AMPS PROVIDE SWITCHING DUTY CIRCUIT BREAKERS FOR LIGHTING CIRCUITS CONTROLLED FROM BREAKER PROVIDE HACR CIRCUIT BREAKERS FOR HVAC AND REFRIGERATION EQUIPMENT ABBREVIATIONS: # (GF) = GROUND FAULT INTERRUPTER, (ST) = SHUNT TRIP, (LO) = LOCK-ON, (IG) = ISOLATED GROUND, (HL)=HAND LOCK *** (GFE) = GROUND FAULT INTERRUPTER FOR EQUIPMENT EX - IN DESCRIPTION INDICATES EXISTING LOAD N - NEW CIRCUIT BREAKER, RETAIN EXISTING BREAKERS FOR RE-USE PANEL: LPSP (EXISTING) 120/208V, 3PH, 4W LOCATION: ELECTRICAL ROOM 225 AMP MLO SUPPLY FROM: MDL 10,000 AIC (MINIMUM) MOUNTING: SURFACE LOAD IN KVA PER PHASE CKT DESCRIPTION BKR PL A B C PL BKR DESCRIPTION CKT 1 EX-FRONT SIGN 20 1 1.20 1.30 2 30 EX-SITE LIGHTING 2 3 EX-FRONT SOFFIT 20 1 1.40 1.30 4 5 EX-FRONT SOFFIT 20 1 1.40 0.00 1 20 EX-SIGNAGE 6 7 EX-FRONT SOFFIT 20 1 1.40 0.00 1 20 EX-SIGNAGE 8 9 EX-FRONT SIGN 20 1 1.40 0.00 1 20 EX-SIGNAGE 10 11 EX-SIGNAGE 20 1 0.00 0.00 1 20 EX-SIGNAGE 12 13 EX-SIGNAGE 20 1 0.00 0.00 1 20 EX-SIGNAGE 14 15 EX-SIGNAGE 20 1 0.00 0.00 1 20 EX-SIGNAGE 16 17 EX-SIGNAGE 20 1 0.00 0.00 1 20 EX-SIGNAGE 18 19 EX-SITE LIGHTING 30 2 1.30 0.00 1 20 EX-SIGNAGE 20 21 1.30 0.00 1 20 EX-SIGNAGE 22 23 DEFROST 20 2 0.00 1.30 2 30 EX-SITE LIGHTING 24 25 0.00 1.30 26 27 DEFROST 40 2 0.00 0.00 1 20 EX-LED SIGN LIGHTING CONTROLLER 28 29 0.00 0.00 1 20 EX-LED SIGN LIGHTING CONTROLLER 30 31 DEFROST 40 3 0.00 0.18 1 20 ROOF TOP GFCI 32 R 33 0.00 0.18 1 20 ROOF TOP GFCI 34 R 35 0.00 0.10 1 20 GAS WATER HEATER IGNITION - ABOVE SF 36 37 DEFROST 40 3 0.00 0.18 1 20 RC PANEL 38 39 0.00 0.00 SPACE 40 41 0.00 0.00 SPACE 42 TOTAL PER PHASE: 6.86 5.58 2.80 KVA TOTAL CONNECTED LOAD: 15.24 KVA 42.33 AMPS FEEDER DEMAND LOAD: 15.24 KVA 42.33 AMPS PROVIDE SWITCHING DUTY CIRCUIT BREAKERS FOR LIGHTING CIRCUITS CONTROLLED FROM BREAKER PROVIDE HACR CIRCUIT BREAKERS FOR HVAC AND REFRIGERATION EQUIPMENT ABBREVIATIONS: # (GF) = GROUND FAULT INTERRUPTER, (ST) = SHUNT TRIP, (LO) = LOCK-ON, (IG) = ISOLATED GROUND, (HL)=HAND LOCK *** (GFE) = GROUND FAULT INTERRUPTER FOR EQUIPMENT EX - IN DESCRIPTION INDICATES EXISTING LOAD N - NEW CIRCUIT BREAKER, RETAIN EXISTING BREAKERS FOR RE-USE R - RELOCATED CIRCUIT FROM PREVIOUS LP3 PANEL PANEL: LPCR (EXISTING) 120/208V, 3PH, 4W LOCATION: ELECTRICAL ROOM 225 AMP MLO SUPPLY FROM: MDP 10,000 AIC (MINIMUM) MOUNTING: SURFACE UPDATE ALL PANEL CIRCUIT BREAKERS WITH 20 AMP SINGLE POLE BREAKERS LOAD IN KVA PER PHASE CKT DESCRIPTION BKR PL A B C PL BKR DESCRIPTION CKT 1 CHECKSTAND REGISTER 20 1 0.72 1.80 1 20 MOBILE HOT FOOD 2 3 CHECKSTAND REGISTER 20 1 0.72 0.80 1 20 TABLE RECEPTACLE - MEAT PREP 4 5 CHECKSTAND REGISTER 20 1 0.72 0.80 1 20 TABLE RECEPTACLE - MEAT PREP 6 7 CHECKSTAND REGISTER 20 1 0.72 1.80 1 20 WRAPPER - MEAT PREP 8 9 CHECKSTAND REGISTER 20 1 0.72 1.80 1 20 WRAPPER - MEAT PREP 10 11 CHECKSTAND REGISTER 20 1 0.72 0.98 1 20 SCALES/ SLICERS - DELI/ SEAFOOD 12 13 EAS DEACTIVATOR, PRINTER, LANE LIGHT 20 1 0.09 0.18 1 20 POWER REEL 14 15 EAS DEACTIVATOR, PRINTER, LANE LIGHT 20 1 0.09 0.00 1 20 SPARE 16 17 RECEPT ACCOUTING 20 1 0.36 0.00 1 20 EX-OFFICE SERVER 18 19 RECEPT CUSTOMER SERVICE 20 1 0.36 0.36 1 20 MDF EQUIPMENT 20 21 RECEPT CUSTOMER SERVICE 20 1 0.36 0.50 1 30 MDF EQUIPMENT 22 23 SPARE 20 1 0.00 0.50 1 30 MDF EQUIPMENT 24 25 SPARE 20 1 0.00 0.36 1 20 MDF EQUIPMENT 26 27 EX-BREAK ROOM 20 1 0.00 0.00 1 20 EX-OFFICE RECEPTACLE 28 29 EX-EXISTING CIRCUIT 20 1 0.00 0.00 1 20 EX-OFFICE RECEPTACLE 30 31 EX-RECEIVING RECEPTACLE 20 1 0.00 0.00 1 20 EX-OFFICE RECEPTACLE 32 33 EAS PEDESTALS 20 1 0.54 0.00 1 20 SPARE 34 35 EAS CONTROLLER 20 1 1.80 0.21 1 20 EX-PHONE BOARD 36 37 EX-OFFICE SYSTEM RECEPTACLE 20 1 0.00 0.20 1 20 EX-PHONE BOARD 38 39 EX-OFFICE SYSTEM RECEPTACLE 20 1 0.00 0.00 1 20 EX-OFFICE RECEPTACLE 40 41 EX-OFFICE SYSTEM RECEPTACLE 20 1 0.00 0.00 1 20 SPARE 42 TOTAL PER PHASE: 6.59 5.53 6.09 KVA TOTAL CONNECTED LOAD: 18.21 KVA 50.57 AMPS FEEDER DEMAND LOAD: 16.35 KVA 45.41 AMPS PROVIDE SWITCHING DUTY CIRCUIT BREAKERS FOR LIGHTING CIRCUITS CONTROLLED FROM BREAKER PROVIDE HACR CIRCUIT BREAKERS FOR HVAC AND REFRIGERATION EQUIPMENT ABBREVIATIONS: # (GF) = GROUND FAULT INTERRUPTER, (ST) = SHUNT TRIP, (LO) = LOCK-ON, (IG) = ISOLATED GROUND, (HL)=HAND LOCK *** (GFE) = GROUND FAULT INTERRUPTER FOR EQUIPMENT EX - IN DESCRIPTION INDICATES EXISTING LOAD N - NEW CIRCUIT BREAKER, RETAIN EXISTING BREAKERS FOR RE-USE PANEL: MDP (EXISTING) 120/208V, 3PH, 4W LOCATION: ELECTRICAL ROOM 800 AMP MLO SUPPLY FROM: UTILITY 65,000 AIC (MINIMUM) MOUNTING: SURFACE SERVICE ENTRANCE RATED LOAD IN KVA PER PHASE CKT DESCRIPTION FUSE PL A B C PL FUSE DESCRIPTION CKT EX 1 LP-1 150 3 14.00 6.79 3 150 LP-2 2 EX 3 10.55 9.04 4 5 11.45 9.28 6 N 7 LP-3 / VIA ATS-EQ 400 3 35.58 6.83 3 100 LP-4 8 EX 9 36.19 10.81 10 11 36.19 8.82 12 EX 13 LP-CR 100 3 6.59 6.86 3 150 LP-SP 14 EX 15 5.53 5.58 16 17 6.09 2.80 18 EX 19 RTU-1 60 3 6.00 6.00 60 150 RTU-2 20 EX 21 6.00 6.00 22 23 6.00 6.00 24 EX 25 RTU-3 25 3 6.00 1.44 3 20 CU-1 26 EX 27 6.00 1.44 28 29 6.00 1.44 30 31 0.00 1.44 3 15 CU-2 32 EX 33 0.00 1.44 34 35 0.00 1.44 36 37 0.00 0.00 38 39 0.00 0.00 40 41 0.00 0.00 42 TOTAL PER PHASE: 97.53 98.59 95.52 KVA TOTAL CONNECTED LOAD: 291.63 KVA 810.09 AMPS FEEDER DEMAND LOAD: 275.95 KVA 766.52 AMPS PROVIDE SWITCHING DUTY CIRCUIT BREAKERS FOR LIGHTING CIRCUITS CONTROLLED FROM BREAKER PROVIDE HACR CIRCUIT BREAKERS FOR HVAC AND REFRIGERATION EQUIPMENT ABBREVIATIONS: # (GF) = GROUND FAULT INTERRUPTER, (ST) = SHUNT TRIP, (LO) = LOCK-ON, (IG) = ISOLATED GROUND *** (GFE) = GROUND FAULT INTERRUPTER FOR EQUIPMENT EX - IN DESCRIPTION INDICATES EXISTING LOAD N - NEW CIRCUIT BREAKER, RETAIN EXISTING BREAKERS FOR RE-USE EM0.1 ENERGY MANAGEMENT COVER SHEET FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 4 : 2 1 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES DISTANCE > 300'-0" DISTANCE < 300'-0" LOAD PER COOLER/FREEZER UP TO 12 AMPS 12 TO 18 AMPS 18 TO 30 AMPS (2) #12 - 1" CONDUIT (2) #10 - 1" CONDUIT (2) #8 - 1" CONDUIT (2) #10 - 1" CONDUIT (2) #8 - 1" CONDUIT (2) #6 - 1" CONDUIT (2) #10 - 1" CONDUIT (2) #12 - 1" CONDUIT (2) #12 - 1" CONDUIT (2) #12 - 1" CONDUIT (2) #12 - 1" CONDUIT (2) #12 - 1" CONDUIT 24V / SINGLE PHASE 120V / SINGLE PHASE 208V / SINGLE PHASE VOLTAGE DISTANCE < 300'-0" DISTANCE > 300'-0" INSTALLATION GUIDES SOLENOID WIRING SCHEDULE 208V COOLING COIL WIRING SCHEDULE A. REFER TO THE E SERIES SHEETS FOR ALL OTHER RELATED SCHEDULES, DETAILS, ETC RELATING TO THIS PLAN. B. PROVIDE A MINIMUM OF (2) 1" CONDUITS FOR EACH REFRIGERATION CIRCUIT, CONSISTING OF (1) CONDUIT FOR LOW VOLTAGE AND (1) FOR LINE VOLTAGE. C. DEFROST WIRING AND SUCTION STOP SOLENOID CABLES MAY BE COMBINED IN THE SAME CONDUIT, ONLY IF OVERALL FILL DOES NOT EXCEED 40% (FIELD VERIFY). D. FURNISH AND INSTALL ALL WIRES AND CABLES. PROVIDE FINAL TERMINATIONS FOR ALL LINE VOLTAGE WIRING UNO, REFRIGERATION CONTRACTOR SHALL MAKE FINAL TERMINATIONS AT BOTH ENDS OF LOW VOLTAGE WIRES / CABLES AND DEFROST WIRING. PROVIDE SUFFICIENT SLACK AT BOTH ENDS TO ALLOW FOR SERVICE LOOPS AND TO FACILITATE PROPER TERMINATIONS. ELSEWHERE, INCLUDING RELATED POWER WIRING SHOWN ON OTHER DRAWING SHEETS, PROVIDE ALL REQUIRED TERMINATIONS. E. IF A DISCREPANCY EXISTS BETWEEN THIS DRAWING AND THE SPECIFICATIONS, REFER TO KROGER PROJECT ENGINEER FOR RESOLUTION. F. WHERE APPLICABLE FOR ISLAND TYPE CASE LOCATIONS, INSTALL CONDUIT BELOW SLAB AND PROVIDE OUTLET BOXES SURFACE MOUNTED JUST ABOVE FLOOR SLAB. G. REFER TO EQUIPMENT SCHEDULES ON E5-SERIES DRAWINGS FOR MOUNTING HEIGHTS AND ADDITIONAL INFORMATION. ALSO SEE DETAILS ON SHEET E5-SERIES DRAWINGS WHERE APPLICABLE. H. INSTALL ELECTRICAL OUTLETS FOR REFRIGERATION ISLAND CASES IN A STRAIGHT LINE ALIGNED WITH THE HUB DRAWING. COORDINATE WITH PLUMBING DIMENSIONS SIGNED PLAN. I. ALL DIMENSIONS INDICATED ON PLANS THAT ARE FROM INTERIOR PARTITIONS WHERE THE RETURN AIR SHAFT IS INDICATED ARE TAKEN FROM THE SALES AREA SIDE OF THE ROOF DECK HIGH PARTITION, NOT THE RETURN AIR SHAFT PARTITION. J. COORDINATE THE UNDERSLAB CONDUIT AND RACEWAY LAYOUT WITH ALL AFFECTED PARTIES PRIOR TO SLAB PLACEMENT. K. PROVIDE 16 FEET OF FLEXIBLE CONDUIT FOR REFRIGERATED CASES SERVED FROM WALL JUNCTION BOXES AND 8 FEET FOR ISLAND REFRIGERATED CASES FOR CONNECTION TO CASES BY THE PHASE II EQUIPMENT CONTRACTOR. L. ALL WALL MOUNTED OUTLETS SERVING REFRIGERATED CASES WITH RETURN AIR PLENUM ABOVE SHALL BE ACCESSIBLE (WITH ALL WIRING PLENUM RATED AS / IF APPLICABLE). M. REFER TO ELECTRICAL DIMENSION PLANS FOR GENERAL DIMENSIONAL INFORMATION THAT SHALL SCHEMATICALLY APPLY FOR CORRESPONDING SYSTEMS WORK. N. IF DEFROST SYMBOL IS SHOWN ON THE PLAN, BUT THE EQUIPMENT IS NOT LISTED IN THE "DEFROST WIRING SCHEDULE", THEN ROUGH-IN THE CONDUIT AND OUTLET BOX (WITH BLANK PLATE) FOR FUTURE TERMINATION. O. REFER TO RISD-11 FOR MOUNTING SPECIFICS (LOCATIONS, HEIGHTS, ETC.) REGARDING REFRIGERATION UNIT ACCESSORIES AND ANCILLIARY EQUIPMENT. P. REFRIGERATION PITS SHOWN FOR REFERENCE ONLY. BEC TO UTILIZE REFRIGERATION TRENCHES FOR ELECTRICAL CONDUIT WHERE EVER POSSIBLE. COORDINATE ALL TRENCHES WITH REFRIGERATION CONTRACTOR AND GENERAL CONTRACTOR. BEC IS RESPONSIBLE FOR ANY ADDITIONAL UNDERFLOOR TRENCHES AS REQUIRED BY ELECTRICAL DRAWINGS. Q. REFER TO SPECIFICATION 11 41 46 (REFRIGERATION CONTROLS INSTALLATION) FOR WORK REQUIREMENTS. WORK REQUIREMENTS ARE IDENTIFIED IN THE INSTALLER RESPONSIBILITY MATRIX. R. REFER TO SPECIFICATION 11 41 63 (FIXTURE AND EQUIPMENT ELECTRICAL INSTALLATION) FOR ADDITIONAL INSTALLATION REQUIREMENTS. A. THE EMS-CONTRACTOR SHALL BE RESPONSIBLE FOR SUPERVISING THE COMPLETE INSTALLATION OF THE ENERGY MANAGEMENT SYSTEM (EMS). THIS SHALL INCLUDE, BUT NOT BE LIMITED TO THE START-UP, PUNCHDOWN, AND PROGRAMMING ADJUSTMENT OF THE REFRIGERATION / BUILDING CONTROL SYSTEM, INCLUDING REFRIGERATION, HVAC, AND LIGHTING CONTROL. B. THE EMS-CONTRACTOR SHALL PROVIDE ALL COORDINATION BETWEEN VARIOUS TRADES, INCLUDING REFRIGERATION, HVAC, AND ELECTRICAL TO ENSURE THAT ALL EQUIPMENT IS PROPERLY CONTROLLED AND THAT ALL CONTROL POINTS HAVE BEEN ACCOMMODATED. THIS SHALL INCLUDE VERIFYING ALL HVAC EQUIPMENT TO BE CONTROLLER, VERIFYING ALL STAGES OF HEATING, COOLING, HEAT RECLAIM, MULTI- SPEED FANS, ETC. AND ENSURING THAT ADEQUATE SENSORS HAVE BEEN SUPPLIED TO ENABLE PROPER CONTROL OF SAME. C. UPON COMPLETION OF THE EMS INSTALLATION, THE EMS-CONTRACTOR SHALL PROVIDE ACCURATE AND COMPLETE AS-BUILT DOCUMENTATION TO THE OWNER AND THE ENGINEER. THIS DOCUMENTATION MUST INCLUDE AN 8-1/2" X 11" PLAN INDICATING THE LOCATIONS OF ALL OF THE CASE CONTROLLERS, PROBES, SENSORS, RELAYS, REMOTE I/O BOARDS AND MODULES, CONTROLLERS, MODEMS, AND REFRIGERANT LEAK SENSORS FOR THE ENTIRE EMS INSTALLATION, INCLUDING REFRIGERATION, HVAC, AND LIGHTING SYSTEMS. THE BEC / FEC SHALL FURNISH AND INSTALL AN 8-1/2" X 11" DRAWING SHOWING THE LOCATIONS OF ALL REFRIGERATION CIRCUITS, THIS DRAWING SHALL BE MOUNTED ADJACENT TO THE CONTROL PANEL. THIS DOCUMENT SHALL ALSO INCLUDE A COMPLETE PRINTOUT SHOWING TERMINATION POINTS, BOARD LAYOUTS, AND INITIAL CONTROL SET POINTS FOR REFRIGERATION, HVAC, AND LIGHTING CONTROL SYSTEMS. D. ONCE THE NEW CONTROL SYSTEM HAS BEEN INSTALLED AND THE HVAC SYSTEMS ARE READY TO BE BROUGHT ONLINE, THE HVAC CONTACTOR MUST PROVIDE THE NECESSARY SUPERVISION FOR STARTUP OF THE CONTROL SYSTEM AND COORDINATE STARTUP WITH DANFOSS ONSITE. THE HVAC CONTRACTOR MUST ENSURE THAT ALL THE HVAC SYSTEMS ARE OPERATING CORRECTLY AND PROVIDE ANY FINE TUNING OF THE SYSTEM THAT IS REQUIRED. E. THIS DRAWING IS DIAGRAMMATIC IN NATURE AND IS INTENDED TO CONVEY INSTALLATION REQUIREMENTS REGARDING THE ENERGY MANAGEMENT CONTROL SYSTEM. THIS DRAWING IS PICTORIALLY DRAWN FOR CLARIFICATION PURPOSES ONLY, DO NOT SCALE. THIS DRAWING IS GENERIC AND NOT ALL COMPONENTS SHOWN ARE REQUIRED FOR INSTALLATION. REFER TO RESPONSIBILITY CHART FOR FINAL EQUIPMENT AND INSTALLATION REQUIREMENTS. F. REFRIGERATION CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ENERGY MANAGEMENT ISSUES REGARDING REFRIGERATED CASES, EVAPORATOR COILS, REFRIGERATION CONDENSERS, PREP ROOM REFRIGERATION, COMPRESSOR RACKS, AND HOT WATER RECLAIM SYSTEMS. IT SHALL BE THE RESPONSIBILITY OF THE REFRIGERATION CONTRACTOR TO ENSURE A FULLY OPERATIONAL SYSTEM. REFER TO DETAIL #2 FOR ADDITIONAL INFORMATION REGARDING CONTRACTOR RESPONSIBILITIES. G. LOW VOLTAGE EMS CONTROL WIRING BY EMS CONTRACTOR. ALL OTHER HIGH VOLTAGE WIRING SHALL BE BY THE GENERAL CONTRACTORS ELECTRICAL CONTRACTOR. H. REFER TO REFRIGERATION LEGENDS FOR INFORMATION REGARDING FIXTURE, WALK-IN COOLER / FREEZERS, EVAPORATORS, CONDENSERS, AND RECLAIM REQUIREMENTS. R PROVIDE (2)#14 FOR CONTROL RELAY & #14 SHIELDED TWISTED PAIR FOR TEMPERATURE SENSOR. IF U.H. HAS CPC BOARD, PROVIDE 4-WIRE SHIELDED CONDUCTOR IN LIEU OF ABOVE. SEE REFRIGERATION WIRING SCHEDULE ON THIS SHEET. PROVIDE POWER WIRING IN 1" EMT CONDUIT FROM RESPECTIVE DANFOSS "RC" PANEL TO FIRST COIL FAN IN MEAT COOLER AND EACH WALK-IN FREEZER, AND FROM FIRST FAN TO OTHER FANS AS / IF APPLICABLE. SEE 208V COOLING COIL FAN WIRING SCHEDULE. 208V COOLING COIL FAN INSTALL & WIRE 2-STAGE THERMOSTAT (FURNISHED BY HVAC CONTRACTOR). CONTACTOR AND CONTROL POWER TRANSFORMER WILL BE PROVIDED (FACTORY INSTALLED) BY DUCT HEATER MANUFACTURER. SEE POWER PLAN FOR POWER WIRING. BELDEN SHIELDED CABLE AS DIRECTED IN FIELD BY REFRIGERATION EQUIPMENT VENDOR. PROVIDE CABLE IN 1" EMT CONDUIT FROM CONTROL PANEL TO CONTROL PANEL USING A LOOP CONFIGURATION (NOT RADIAL). CONTROL PANELS SHALL BE FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. S VERIFY IN FIELD. BELDEN #8760 #18-2 SHIELDED CABLE OR APPROVED EQUAL (PLENUM RATED IF APPLICABLE). BELDEN #8771 #18-3 SHIELDED CABLE OR APPROVED EQUAL (PLENUM RATED IF APPLICABLE). PROVIDE OUTLET BOX MOUNTED ON COLUMN AT 7'-6" ABOVE FINISHED FLOOR. PROVIDE CABLE IN 3/4" EMT CONDUIT FROM TEMPERATURE SENSOR TO "BC" CONTROL PANEL. TEMPERATURE SENSOR SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. SEE DETAIL ESD-46 ON E5-SERIES DRAWINGS. PROVIDE OUTLET BOX MOUNTED ON COLUMN AT 7'-6" ABOVE FINISHED FLOOR. PROVIDE CABLE IN 3/4" EMT CONDUIT FROM HUMIDITY SENSOR TO "BC" CONTROL PANEL. HUMIDITY SENSOR SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. SEE DETAIL ESD-46 ON E5-SERIES DRAWINGS. PROVIDE OUTLET BOX AT COOLER / FREEZER DOOR AS DIRECTED BY REFRIGERATION CONTRACTOR. PROVIDE CABLE IN 1" EMT CONDUIT FROM SENSOR TO RESPECTIVE "RC" PANEL. SENSOR SHALL BE FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. PROVIDE OUTLET BOX AT CASE. PROVIDE CABLE IN 1" CONDUIT FROM SENSOR TO RESPECTIVE "RC" CONTROL PANEL. SENSOR SHALL BE FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. PROVIDE OUTLET BOX AT CASE. PROVIDE CABLE IN 1" CONDUIT FROM SOLENOID TO RESPECTIVE "RC" CONTROL PANEL. SOLENOID SHALL BE FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. PROVIDE CABLE IN 3/4" EMT CONDUIT BETWEEN ROOFTOP HVAC UNITS AND FROM RTU'S TO "BC" CONTROL PANEL AS SHOWN. PROVIDE CABLE IN 3/4" EMT CONDUIT BETWEEN UNIT HEATERS AND FROM UNIT HEATER(S) TO "BC" CONTROL PANEL AS SHOWN. PROVIDE CABLE IN 3/4" EMT CONDUIT BETWEEN DOMESTIC HOT WATER RECLAIM TANKS AND FROM TANK(S) TO "BC" CONTROL PANEL AS SHOWN. IMMERSIBLE TEMP SENSOR SHALL BE FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. T BELDEN #6841 #18-2 SHIELDED CABLE OR APPROVED EQUAL (PLENUM RATED IF APPLICABLE). PROVIDE SELF-REGULATING HEATING CABLE (WITH CONDUIT STUB-UPS) BELOW FREEZER FLOOR AS INDICATED ON DETAIL ESD-7 ON E5-SERIES DRAWINGS. SEE DETAIL ESD-7 ON E5-SERIES DRAWINGS. SUCTION STOP SOLENOID DOOR SENSOR UNDERFLOOR HEATING CABLES TEMPERATURE SENSOR (REFRIGERATION) TEMPERATURE SENSOR (HVAC) HUMIDITY SENSOR ROOFTOP UNIT UNIT HEATER EXISTING RECLAIM TANK SEE SOLENOID WIRING SCHEDULE ON THIS SHEET. ELECTRIC DUCT HEATER RU PROVIDE CABLE IN 3/4" EMT CONDUIT FROM EACH CONTROLLER TO ASSOCIATED REMOTE CONDENSER. PROVIDE OUTLET BOX AT CASE. PROVIDE CABLE IN 1" CONDUIT FROM EPR TO RESPECTIVE "RC" CONTROL PANEL. EPR SHALL BE FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. EVAPORATOR PRESSURE REGULATOR #14 TWISTED PAIR (PLENUM RATED IF APPLICABLE). BELDEN #8760 #18-2 SHIELDED CABLE OR APPROVED EQUAL (PLENUM RATED IF APPLICABLE). BELDEN #8760 #18-2 SHIELDED CABLE OR APPROVED EQUAL (PLENUM RATED IF APPLICABLE). BELDEN #8760 #18-2 SHIELDED CABLE OR APPROVED EQUAL (PLENUM RATED IF APPLICABLE). PROVIDE OUTLET BOX AT CASE. PROVIDE WIRING FROM CASE TO RESPECTIVE REFRIGERATION UNIT "RC" PANEL (1 OR 3 PHASE AS SCHEDULED), SEE DEFROST WIRING SCHEDULE. PROVIDE WIRING IN 1" CONDUIT FOR WALK-IN COOLERS / FREEZERS AND ALL OTHER APPLICATIONS. IN ADDITION, PROVIDE 1" CONDUIT FOR KLIXON UNITS. KLIXON UNITS TO BE WIRED IN SERIES PER REFRIGERATION CIRCUIT WITH A SINGLE HOME RUN TO "RX" PER CIRCUIT. DEFROST CONDUIT CONDUIT: BEC WIRE: FEC BRANCH DEFROST CONDUIT SEE REFRIGERATION WIRING SCHEDULE ON THIS SHEET. PROVIDE OUTLET BOX AT CASE. PROVIDE WIRING FROM CASE TO RESPECTIVE (1 OR 3) PHASE DEFROST CONNECTION POINT PER RISD-13 (WHERE APPLICABLE), OR DIRECTLY TO REFRIGERATION UNIT UNIT. SEE DEFROST WIRING SCHEDULE. PROVIDE WIRING IN 1" CONDUIT FOR ALL OTHER APPLICATIONS. IN ADDITION, PROVIDE 1" CONDUIT FOR KLIXON UNITS. KLIXON UNITS TO BE WIRED IN SERIES PER REFRIGERATION CIRCUIT WITH A SINGLE HOME RUN TO "RX" PER CIRCUIT. SEE REFRIGERATION WIRING SCHEDULE ON THIS SHEET. REFER TO SPECIFICATION 26.05.19 FOR CABLING REQUIREMENTS AND ADDITIONAL INFORMATION. RECLAIM 3-WAY VALVE PROVIDE CABLE IN 3/4" EMT CONDUIT BETWEEN 3-WAY VALVE AND "RC" CONTROL PANEL. PROVIDE OUTLET BOX AT CASE. PROVIDE CABLE IN 1" CONDUIT FROM SENSOR TO RESPECTIVE "RC" CONTROL PANEL. SENSOR SHALL BE FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. DEFROST TERMINATION THERMOSTAT BELDEN #8760 #18-2 SHIELDED CABLE OR APPROVED EQUAL (PLENUM RATED IF APPLICABLE). #ROUTE INDICATED HOME-RUNS AS FOLLOWS, FIELD VERIFY ALL PANEL LOCATIONS. WHERE REFRIGERATION EQUIPMENT IS SERVED FROM A "SYSTEM", ROUTE TO "RC" CONTROL PANEL IN REAR COMPRESSOR ROOM. WHERE REFRIGERATION EQUIPMENT IS SERVED FROM RACK "A" OR RACK "B", ROUTE TO RESPECTIVE RACK'S "RC" CONTROL PANEL IN REAR COMPRESSOR ROOM. WHERE REFRIGERATION EQUIPMENT IS SERVED FROM A REFRIGERATION UNIT UNIT, ROUTE TO RESPECTIVE REFRIGERATION UNIT UNIT'S "RC" CONTROL PANEL. IN THE NOTES STATED ABOVE, PROVIDE SHALL MEAN FURNISH AND INSTALL. "BEC" TO REFER TO BUILDING ELECTRICAL CONTRACTOR BIDDING TO THE GENERAL CONTRACTOR, "FEC" TO REFER TO FIXTURING ELECTRICAL CONTRACTOR SEPARATELY BIDDING EQUIPMENT TO KROGER. , BEC AND FEC RESPONSIBILITIES WILL BE COMBINED AND FALL TO THE ELECTRICAL CONTRACTOR BIDDING TO THE GENERAL CONTRACTOR. FEC TO PROVIDE AND WIRE ALL ADDITIONAL CONTACTORS, RELAYS, AND ADDITIONAL ENCLOSURES NECESSARY FOR A FULLY FUNCTIONAL DEFROST SYSTEM. REFER TO REFRIGERATION VENDOR EQUIPMENT SCHEDULE FOR REFRIGERATION UNIT SYSTEMS AS THESE ARE TYPICALLY PROVIDED WITH THE REFRIGERATION UNIT UNIT. FOR RACK AND PARALLEL SYSTEMS, ASSUME NONE ARE PROVIDED BY THE MANUFACTURER. REFER TO REFRIGERATION CONTROL EQUIPMENT RESPONSIBILITY SCHEDULE IN SPECIFICATION 11 41 46 FOR RESPONSIBILITIES OF ALL LOW VOLTAGE CABLING AND OTHER EMS SPECIALTIES. FROZEN FOOD CASE MOTION SENSORS FOR CONTROL OF CASE LIGHTING, SENSOR TO BE CONTROL POWER FOR CASE LIGHTS. SEE DETAIL EISD-1 ON E5-SERIES DRAWINGS. MOTION SENSOR (APPLIES ONLY FOR EMS DRAWING SHEETS) SYMBOL DESCRIPTION CABLE/CONDUCTORS NOTE INSTALLATION RESPONSIBILITY 3DC# CONDUIT: BEC WIRE: FEC 1DC# DC# CF# CONDUIT: BEC WIRE: BEC SS# CONDUIT: BEC WIRE: BEC EPR# CONDUIT: BEC WIRE: BEC DS CONDUIT: BEC WIRE: FEC CONDUIT: BEC WIRE: BEC FH TS# CONDUIT: BEC WIRE: FEC DT CONDUIT: BEC WIRE: FEC "RC" "RX" "BC" "BX" REFRIGERATION CONTROL PANEL BUILDING CONTROL PANEL CONDUIT: BEC WIRE: FEC CONDUIT: BEC WIRE: BEC CONDUIT: BEC WIRE: BEC HS CONDUIT: BEC WIRE: BEC MS CONDUIT: BEC WIRE: FEC CONDUIT: BEC WIRE: BEC CU CONDENSING UNIT UH CONDUIT: BEC WIRE: BEC RT CONDUIT: BEC WIRE: BEC DH CONDUIT: BEC WIRE: BEC 3W CM CB DEFROST SCHEDULE J959 REFRIGERATION DEFROST WIRING CHART Protocol Unit Circuit 1Ph Breaker Size Wire Size 3Ph Breaker Size Wire Size F 1 40/3P (3)#8,(1)#10G F 2 40/3P (3)#8,(1)#10G F 3 20/2P (2)#10,(1)10G G 1 40/2P (2)#8,(1)#10G E 1 2 3 4 D C B A SY S T E M H SY S T E M H SY S T E M H SYSTEM H SYSTEM A SYSTEM B SYSTEM B SYSTEM C SYSTEM D SYSTEM F SYSTEM G SYSTEM E SYSTEM F SY S T E M E TS TS 3DC 1DC SS SS DT TS 1DC SS DT DC DT DC DC DC 3DC SS DT DC DC DT GGDNIC8HI GGDNIC8HI GGDNLT12HI GGDNLT12HI GGDITT10HI GGDITT12HI GGDITT10HI GG D N I C 6 P H I GG D N I C 6 P H I DC DC TS TS TS TS SCALE: 3/32"=1'-0" 1 EM1.A ENERGY MANAGEMENT PLAN 119 ACCT. 118 CUSTOMER SERVICE XXX CHECKLANES 100 SALES 117 MEN 116 WOMEN 114 STORAGE 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 104 MEAT PREP 102 PRODUCE PREP 101 HALL "C" 111 JANITOR'S CLOSET FAN COIL FAN COIL FAN COIL FAN COIL FAN COIL FAN COIL EM1.1 ENERGY MANAGEMENT PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 4 : 4 1 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 GENERAL NOTES A. PROVIDE A MINIMUM OF (2) 1" CONDUITS FOR EACH REFRIGERATION CIRCUIT, CONSISTING OF (1) CONDUIT FOR LOW VOLTAGE AND (1) FOR LINE VOLTAGE. B. DEFROST WIRING AND SUCTION STOP SOLENOID CABLES MAY BE COMBINED IN THE SAME CONDUIT, ONLY IF OVERALL FILL DOES NOT EXCEED 40% (FIELD VERIFY). C. FURNISH AND INSTALL ALL WIRES AND CABLES. PROVIDE FINAL TERMINATIONS FOR ALL LINE VOLTAGE WIRING UNO, REFRIGERATION CONTRACTOR SHALL MAKE FINAL TERMINATIONS AT BOTH ENDS OF LOW VOLTAGE WIRES / CABLES AND DEFROST WIRING. PROVIDE SUFFICIENT SLACK AT BOTH ENDS TO ALLOW FOR SERVICE LOOPS AND TO FACILITATE PROPER TERMINATIONS. ELSEWHERE, INCLUDING RELATED POWER WIRING SHOWN ON OTHER DRAWING SHEETS, PROVIDE ALL REQUIRED TERMINATIONS. D. IF A DISCREPENCY EXISTS BETWEEN THIS DRAWING AND SPECIFICATIONS, SPECIFICATIONS SHALL PREVAIL. E. WHERE APPLICABLE FOR ISLAND TYPE CASE LOCATIONS, INSTALL CONDUIT BELOW SLAB AND PROVIDE OUTLET BOXES SURFACE MOUNTED JUST ABOVE FLOOR SLAB. F. REFER TO EQUIPMENT SCHEDULES ON E5-SERIES DRAWINGS FOR MOUNTING HEIGHTS AND ADDITIONAL INFORMATION. ALSO SEE DETAILS ON SHEET E5-SERIES DRAWINGS WHERE APPLICABLE. G. INSTALL ELECTRICAL OUTLETS FOR REFRIGERATION ISLAND CASES IN A STRAIGHT LINE ALIGNED WITH THE HUB DRAWING. COORDINATE WITH PLUMBING DIMENSIONS SIGNED PLAN. H. ALL DIMENSIONS INDICATED ON PLANS THAT ARE FROM INTERIOR PARTITIONS WHERE THE RETURN AIR SHAFT IS INDICATED ARE TAKEN FROM THE SALES AREA SIDE OF THE ROOF DECK HIGH PARTITION, NOT THE RETURN AIR SHAFT PARTITION. I. COORDINATE THE UNDERSLAB CONDUIT AND RACEWAY LAYOUT WITH ALL AFFECTED PARTIES PRIOR TO SLAB PLACEMENT. J. PROVIDE 10 FEET OF FLEXIBLE CONDUIT FOR REFRIGERATED CASES SERVED FROM WALL JUNCTION BOXES AND 6 FEET FOR ISLAND REFRIGERATED CASES FOR CONNECTION TO CASES BY THE PHASE II EQUIPMENT CONTRACTOR. K. ALL WALL MOUNTED OUTLETS SERVING REFRIGERATED CASES WITH RETURN AIR PLENUM ABOVE SHALL BE ACCESSIBLE (WITH ALL WIRING PLENUM RATED AS/IF APPLICABLE). L. REFER TO ELECTRICAL DIMENSION PLANS FOR GENERAL DIMENSIONAL INFORMATION THAT SHALL SCHEMATICALLY APPLY FOR CORRESPONDING SYSTEMS WORK. M. IF DEFROST SYMBOL IS SHOWN ON THE PLAN, BUT THE EQUIPMENT IS NOT LISTED IN THE "DEFROST WIRING SCHEDULE", THEN ROUGH-IN THE CONDUIT AND OUTLET BOX (WITH BLANK PLATE) FOR FUTURE TERMINATION. N. REFER TO RISD-11 FOR MOUNTING SPECIFICS (LOCATIONS, HEIGHTS, ETC.) REGARDING PROTOCOL UNIT ACCESSORIES AND ANCILLARY EQUIPMENT. O. REFRIGERATION PITS SHOWN FOR REFERENCE ONLY. BEC TO UTILIZE REFRIGERATION TRENCHES FOR ELECTRICAL CONDUIT WHERE EVER POSSIBLE. COORDINATE ALL TRENCHES WITH REFRIGERATION CONTRACTOR AND GENERAL CONTRACTOR. BEC IS RESPONSIBLE FOR ANY ADDITIONAL UNDER FLOOR TRENCHES AS REQUIRED BY ELECTRICAL DRAWINGS. P. PROVIDE HOME-RUN(S) FOR INDICATED EQUIPMENT / DEVICES TO EXISTING REFRIGERATION UNIT "PU-A" PANELBOARD. PROVIDE 208V/1 ∅ HOME-RUN(S) FOR DEFROST CIRCUITS AND 208V WALK-IN FREEZER/COOLER COILS (SEE SCHEDULES). PROVIDE NEW BRANCH CIRCUIT BREAKER(S), TO MATCH EXISTING, IF REQUIRED. TERMINATE ALL WIRING AS DIRECTED BY REFRIGERATION VENDOR. Q. PROVIDE HOME-RUN(S) FOR INDICATED EQUIPMENT / DEVICES TO NEW REFRIGERATION UNIT "PU-B" PANELBOARD. PROVIDE 208V/1 ∅ HOME-RUN(S) FOR DEFROST CIRCUITS AND 208V WALK-IN FREEZER / COOLER COILS (SEE SCHEDULES). TERMINATE ALL WIRING AS DIRECTED BY REFRIGERATION VENDOR. 1 PROVIDE ALL REQUIRED CONDUIT AND WIRING. 2 PROVIDE JUNCTION/OUTLET BOXES AT CASES OR COILS AS APPLICABLE. 3 PROVIDE SEPARATE CONDUITS FOR EACH HOME-RUN TYPE (LIGHTS, ANTI-SWEATS, FANS, 208V DEFROSTS, 208V COIL FANS). 4 PROVIDE MINIMUM 1" CONDUIT FOR ALL 208V WIRING HOME-RUNS. FEED FROM WALL WHERE CASE IS LOCATED AGAINST A WALL. 5 SEE DEFROST FAN WIRING SCHEDULE FOR 208V DEFROST HOME-RUN WIRING REQUIREMENTS. 6 SEE 208V COILING COIL FAN WIRING SCHEDULE FOR 208V COIL HOME-RUN WIRING REQUIREMENTS. 7 TERMINATE ALL WIRING AS DIRECTED BY REFRIGERATION VENDOR. 8 PROVIDE SUFFICIENT SLACK AT BOTH ENDS TO ALLOW FOR SERVICE LOOPS AND TO FACILITATE PROPER TERMINATIONS. 9 FIELD VERIFY ALL PANEL LOCATIONS FOR REFRIGERATION EQUIPMENT SERVED FROM AN EXISTING SYSTEM OR PROTOCOL UNIT, 10 PROVIDE HOME-RUN(S) TO RESPECTIVE SYSTEM OR PROTOCOL UNIT. 11 IF DEFROST SYMBOL IS SHOWN ON THE PLAN, BUT THE EQUIPMENT IS NOT LISTED IN THE "DEFROST WIRING SCHEDULE", THEN ROUGH-IN THE CONDUIT AND OUTLET BOX (WITH BLANK PLATE) FOR FUTURE TERMINATION. 12 REFER TO RISD-11 (KROGER DRAWINGS) FOR TYPICAL VSD/REMOTE DEFROST INSTALLATION LOCATIONS (UNLESS OTHERWISE NOTED). CM CB 1 +1 2 + 5 S h l d S h l d 1+ 1 - 2 + 2 - 3 + 3 - 4 + 4 - +1 2 + 5 S h l d S h l d 5+ 5 - 6 + 6 - 7 + 7 - 8 + 8 - NO 1 AD A P - K O O L AK 2 - X M 2 0 5 B No . 0 8 0 Z 0 0 1 5 Ex t e n s i o n 8 A I 8 D O PR E S S P R E S S R Re l a y O v e r r i d e 1 1 Po w e r Co m m E r r o r OF F - A U T O - O N Ov e r r i d e Re l a y OV R 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 OV R 2 OV R 3 OV R 4 OV R 5 OV R 6 OV R 7 OV R 8 NC C NO 2 NC C NO 3 NC C NO 4 NC C NO 5 NC C NO 6 NC C NO 7 NC C NO 8 NC C +12 +5 ShldShld 1+ 1- 2+ 2- 3+ 3- 4+ 4- +12 +5 ShldShld 5+ 5- 6+ 6- 7+ 7- 8+ 8- NO 1 ADAP-KOOL AK2-XM 205B No. 080Z0015 Extension 8AI8DO PRESS P R E S S R Relay Override 1 1 Power Comm Error OFF-AUTO-ON Override Relay OVR 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 OVR 2 OVR 3 OVR 4 OVR 5 OVR 6 OVR 7 OVR 8 NC C NO 2 NC C NO 3 NC C NO 4 NC C NO 5 NC C NO 6 NC C NO 7 NC C NO 8 NC C Sig Sig Sig Gnd Gnd Gnd Gnd Sig Gnd Gnd Gnd Sig Sig Sig Gnd Sig Length of Run bd. / 23-2500GL) output option C01680420 Dual 4-20mA Output Board C01703300 Install charcoal filter at unit, and outside ait filter on the outside of building. (Install outside) In-Line Filter Charcoal Filter C01680417 (Part of 4-20 ma C01703200 C01680408 18 gauge, non-shielded cable 18 gauge, shielded cable and ppm inputs. and wire as shown. (18 awg.) Run 2-conductor shielded cable to AK2 module Install 250 ohm precision resistors at zone 250 ohm resistor Spill Alarm Run tubing from HGM-300 to each location and install filters at each sample point. Run 120 vac to HGM-300. 13 14 15 16 17 18 19 20 21 24 23 22 SHLD AI5 AI6 AI7 AI8 +12 +5 SHLD +5 +12 AI4 AI3 AI2 12 11 10 9 8 7 6 5 4 3 2 AI1 1 080Z0007 NLNL Main Pwr Gnd Pwr Aux 4NO4NC 120 VAC Evacuate Alarm System Fault Alarm Leak Alarm Purge Zone-1 Zone-2 Zone-3 (Outside Air intake) Zone-4 Zone-5 Zone-6 Zone-8 Zone-7 Tubing End Of Line Filter Evacuate Leak Spill 4C 3NO3NC 2NO2NC 3C 1NC 1NO 1C 2C Gnd RS485 Exhaust B A Common Common Loop 1 Zone Loop 2 PPM AK2 Module HGM300 PPM signal HGM300 Zone signal Sys Fault HGM-300 RCO TP-78 RESET ADAP-KOOL No. 080Z0061 AK2-CM 101A SERVICE R STATUS 3 STATUS 2 ERROR STATUS 1 POWER POWER COMM ERROR ADAP-KOOL AK2-XM 101A No. 080Z0027 Extension AI8 PRESS P R E S S R EM5.1 ENERGY MANAGEMENT DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 4 : 4 8 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 CM CB LIGHTING CONTACTOR PANEL L2 NOTES: 2. 1. 4. 3. L1 O C L 24V L O C L O C 24V 24V 5. DATE: SCALE: NONE DRAWN: CONTROL SYSTEM - LIGHTING CONTROL EMS-1 09/27/11 .. Comm Module: Code # 080Z0016 Address 5 Location: Rack B Condenser Code#080Z0016 8 DO 5 1 1 NC Condenser Fan 5 1 2 NC Condenser Fan I/O MODULE POINT NUMBER MODULE ADDRESS I/O MODULE NUMBER 8 73 7 7 3 5 4 6 56 4 RCO TP-78 10 8 9 2 0 8 9 2 1 3 56 4 2 109 MODULE ADDRESS SET AT ZERO 8 73 7 7 3 5 4 6 56 4 RCO TP-78 10 89 2 0 89 21 3 56 4 2109 RESET ADAP-KOOL No. 080Z0061 AK2-CM 101A SERVICE R STATUS 3 STATUS 2 ERROR STATUS 1 POWER G + -S AB MODULE 5-1 MODULE 5-2 MODULE 5-3 COMM MODULE DATE: SCALE: NONE DRAWN: KEY AND COMM MODULE SETTINGS EMS-2 09/27/11 .. (FROZEN FOOD & ICE CREAM) N MULTI-DECK L I O C F ACOIL (FROZEN FOOD & ICE CREAM) GLASS DOOR REACH-IN COIL MULTI-DECK TOP MOUNT COIL (DAIRY/DELI) F A N C O I L MULTI-DECK (DAIRY/DELI/MEAT) 4. 3. 5. 1. 2. NOTES: TS TS TS TS DATE: SCALE: NONE DRAWN: CONTROL SYSTEM - CASE TEMPERATURE SENSOR LOCATIONS (MULTI DECK) TS-1 09/27/11 .. DATE: SCALE: NONE DRAWN: CONTROL SYSTEM - CASE TEMPERATURE SENSOR LOCATIONS (SINGLE DECK) TS-2 09/27/11 .. (FROZEN FOOD & ICE CREAM) BACK-TO-FRONT DISCHARGE WIDE ISLAND NOTES: FRONT-TO-BACK DISCHARGE (FROZEN FOOD & ICE CREAM) WIDE ISLAND (PRODUCE) TOP DISCHARGE FAN (PRODUCE MODEL) TYPICAL ISLAND COIL (MEAT, PRODUCE & ICE CREAM) SINGLE DECK COIL 4. 3. 5. 1. 2. TS TS TS TS TS TS TS THE STANDARD TEMPERATURE SENSOR, LOCATION IS TO BE VERIFIED BY THE ENERGY MANAGEMENT SYSTEM CONTRACTOR. THE STANDARD TEMPERATURE SENSOR IS TO BE MOUNTED IN THE PRIMARY DISCHARGE AIR PLENUM. CONTRACTOR IS TO LABEL EACH SENSOR CABLE WITH THE SYSTEM NUMBER ON BOTH ENDS. CONTRACTOR TO PROVIDE CONDUIT TO ABOVE THE CEILING AREA, OR 10'-0" AB. FL. FOR EACH CIRCUIT'S SENSOR WIRING. NO LINE VOLTAGE WIRING OR CONTROL WIRING PERMITTED IN THIS CONDUIT. CONTRACTOR TO INSTALL AND TERMINATE CABLE FROM EACH CASE SENSOR TO THE APPROPRIATE ANALOG INPUT CARD FOR THE REFRIGERATION RACK CONCERNED TEMP SENSOR 2/C - 18AWG CABLE BELDEN #8761 (DANFOSS P/N : 084N002700) COOLER BOX WITH ONE REFRIGERATION CIRCUIT DISCHARGE COOLER BOX COOLER BOX TEMP SENSOR RETURN AIR AIR DISCHARGE AIR COOLER BOX (TWO WAY BLOWER COIL) EVAPORATOR DISCHARGE AIR AIR RETURN TYPICAL AI TERMINATION AIR DISCHARGE COOLER BOX TEMP SENSOR TEMP SENSORS COOLER BOX DISCHARGE AIR AIR DISCHARGE COIL #2 COOLER BOX WITH ONE REFRIGERATION CIRCUIT COOLER BOX WITH ONE EVAPORATOR TOP VIEW OF COOLER BOX TOP VIEW OF COOLER BOX WITH MORE THAN ONE EVAPORATOR COIL #1 2. 3. 4. 5. NOTES: 1. +12+5ShldShld 1+ 1- 2+ 2- 3+ 3- 4+ 4- PRESS TS TS TS DANFOSS TEMPERATURE SENSOR (ATTACH TO FAN GUARD) THE STANDARD TEMPERATURE SENSOR (DANFOSS P/N: 084N002700) IS TO BE MOUNTED & LOCATION VERIFIED BY THE CONTRACTOR. THE STANDARD TEMPERATURE SENSOR IS TO BE MOUNTED IN THE RETURN AIR STREAM. CONTRACTOR IS TO LABEL EACH SENSOR CABLE WITH THE SYSTEM NUMBER ON BOTH ENDS. CONTRACTOR TO PROVIDE CONDUIT TO ABOVE THE CEILING AREA, OR 10'-0" AB. FL. FOR EACH CIRCUIT'S SENSOR WIRING. NO LINE VOLTAGE WIRING OR CONTROL WIRING PERMITTED IN THIS CONDUIT. CONTRACTOR TO INSTALL AND TERMINATE CABLE FROM EACH SENSOR TO THE APPROPRIATE ANALOG INPUT CARD FOR THE REFRIGERATION RACK CONCERNED. DATE: SCALE: NONE DRAWN: CONTROL SYSTEM - TEMPERATURE SENSOR INSTALLATION (COOLER BOX) TS-4 09/27/11 .. OU T P U T S I N P U T S LIGHT LEVEL SENSORS LIGHTING CONTACTORS / ZONES HEATING STAGES COOLING STAGES FAN SPACE TEMPERATURE SENSOR RELATIVE HUMIDITY SENSOR RETURN TEMPERATURE SENSOR OUTDOOR TEMPERATURE SENSOR DESCRIPTION FOUR FOUR TWO ONE ONE LARGE RTU GUH ONE ONE TWO ONE COMMON ONE SMALL RTU TWO FIELD VERIFY ONE LIGHTING ONE SEE EM-2 FOR LOCATIONS FINAL CONNECTIONS BY KROGER (BOTH ENDS), FURNISH AND INSTALL IN CONDENSER CONTROL PANEL INSTALL IN ELECTRICAL ROOM RIC-SEAL PENETRATIONS ONE ON ROOF FACING NORTH, ONE ON INSIDE FOR SKYLIGHTS LOCATE NEAR ELECTRICAL LIGHTING PANEL RIC-SEAL PENETRATIONS SEE ARCHITECTURALS FOR DETAILS EMS-C TO CONNECT HOT WATER HEAT TEMPERATURE SENSOR PROVIDED BY KROGER. POWER WIRING BY EC F / I UNDERGROUND EMS CONDUIT HVAC CONTROL EQUIPMENT UNDERGROUND EMS CONDUIT REM - REFRIGERATION EQUIPMENT MANUFACTURER (OEM) KROGER - OWNER F / I - FURNISH AND INSTALL CATEGORY-5 NETWORK CABLE TO ECR ROOM F - FURNISH I - INSTALL NETWORK TO REMOTE MODULE RTU BOARDS SALES AREA TEMPERATURE SENSORS DESCRIPTION NO-SWEAT PANELS NETWORK WIRING AMBIENT SENSORS WIRING TO AK-SC255 WIRING TO HVAC FIELD SENSORS RELATIVE HUMIDITY SENSORS ENVIRONMENTAL CONTROLLER PANEL F / I EMS-C - EMS CONTRACTOR RIC - REFRIGERATION INSTALLATION CONTRACTOR EC - ELECTRICAL CONTRACTOR HVAC-M - HVAC EQUIPMENT MANUFACTURER (OEM) HVAC-C - HVAC CONTRACTOR LEGEND F / I F F F F RESPONSIBILITY REM RIC KROGER F I F / I F / I F / I F / I I I I EC EMS-C I LIGHTING CONTROL EQUIPMENT REM DESCRIPTION CLEAN POWER/ JUNCTION BOXES TO DANFOSS PANELS LIGHTING CONTROL CONTACTORS (EXCLUDING HA, HB, HC, LC) WIRING FROM CONTROL BOARDS TO CONTACTORS MODULES W/ENCLOSURE AND TRANSFORMER LOW LIGHT SENSORS COMMUNICATION NETWORK WIRING PROVIDE ELECTRICAL FOR ALL DANFOSS CONTROLS WIRING TO HOT WATER RECLAIM CONTROL WALK-IN DOOR SWITCHES UNDERGROUND EMS CONDUIT SPORT II EPR VALVES RESPONSIBILITY RIC KROGER F F F / I I F / I F / I EC I EMS-C I F I F / I F / I F / I F / I F / I F / I REFRIGERATION CONTROL EQUIPMENT REM F / I F / I DESCRIPTION WALK-IN COOLER / FREEZER ANALOG TEMPERATURE SENSORS CONDENSER RELAY MODULES W/ENCL & TRANSFORMERS REFRIG LIQUID LINE SOLENOID VALVES (WHEN APPLICABLE) WIRING TO REFRIGERATION LIQUID LINE SOLENOID VALVES WIRING TO REFRIGERATION FIELD SENSORS I/O MODULES & TRANSFORMERS IN RACKS REFRIGERATED FIXTURE ANALOG TEMPERATURE SENSORS WIRING TO REFRIGERATION SUCTION STOP SOLENOID VALVES DEFROST TERMINATION WIRING NETWORK WIRING BETWEEN RACK CONTROLLERS RACK SENSORS AND TRANSDUCERS RACK CONTROLLER UNITS F / I F RESPONSIBILITY RIC KROGER F / I F / I F / I F / I I AS APPLICABLE CONDUIT BY EC EC EMS-C AS APPLICABLE COMMENTS COMMENTS COMMENTS F MAY BE MOUNTED ABOVE PANELBOARD LEAVE ENDS NEATLY COILED. COMMENTS EMS-C EC F / I KROGER RIC REM RESPONSIBILITY F / I EMERGENCY GENERATOR REMOTE ANNUNCIATOR DESCRIPTION MODEM - EMS CONTROLLER GENERAL LOCATE IN CUSTOMER SERVICE AREA FOR DIVISIONS WITH 3rd PARTY MAINTENANCE ONLY -- MOTIION SENSORS FOR LOCAL DEPARTMENT LIGHTS NOT CONNECTED TO EMS. MOTION DETECTORS SUPPLIED & INSTALLED BY ELECTRICAL CONTRACTOR -- NETWORK WIRING TO CONDENSERS F / I WIRING BETWEEN RACK AND HVAC CONTROLLERS F / I WALK-IN DEFROST THERMOSTATS LOW TEMP F / I F / I HOT WATER HEAT RECLAIM TEMPERATURE PROBE IF WALK-IN LOCAL BOOR ALARM F / I SUCTION STOP F I LOOP PIPING HVAC-M HVAC-M HVAC-M HVAC-M MODULES FOR AAON SMALL RTU'S F / I F / I MODULES FOR AAON RN26 THRU RN70 RTU'S THESE CHARTS FOR REFERRAL ONLY - VERIFY RESPONSIBILITIES WITH KROGER PROJECT MANAGER AND GENERAL CONTRACTOR PRIOR TO BID I F EPR F I LOOP PIPING HVAC/LIGHTING CONTROL POINT SCHEDULE THIS DRAWING REPRESENTS A TYPICAL STORE, AND SERVES AS A TEMPLATE FOR DEVELOPING JOB SPECIFIC DRAWINGS. YOUR DRAWINGS SHALL REFLECT THE DESIGN REQUIREMENTS FOR YOUR SPECIFIC STORE, AND SHALL USE THE LAYOUT ESTABLISHED BY THIS TEMPLATE. USE OF THE TEMPLATE IS NECESSARY TO SUPPORT THE DESIGN, AND PROCUREMENT SYSTEMS WITHIN THE KROGER COMPANY. REFER TO SHEET EM SERIES SHEETS FOR STORE SPECIFIC CONTROL POINT CONNECTIONS.. A2- A1- A1+ A2+ 8 8 Extension 8AI8DO OVERRIDE RELAY +12V ADAP-KOOL 7 6 7 6 4 5 3 4 5 3 COMM ERROR 1 2 1 2 POWER R OVR7 OVR8 OFF - AUTO - ON OVR4 OVR5 OVR6 OVR2 OVR3 OVR1 RELAY OVERRIDE A4- A3- A3+ A4+ +12V +5V shld shld A5+ A5- A6+ A6- A7+ A7- A8+ A8- shld +5V shld 1C 1NC 2NO 3C 3NC 4NO 5C 5NC 6NO 7C 7NC 8NO 8NC 8C 7NO 6NC 6C 5NO 4NC 4C 3NO 2NC 2C 1NO A2- A1- A1+ A2+ 8 8 Extension 8AI8DO OVERRIDE RELAY +12V ADAP-KOOL 7 6 7 6 4 5 3 4 5 3 COMM ERROR 1 2 1 2 POWER R OVR7 OVR8 OFF - AUTO - ON OVR4 OVR5 OVR6 OVR2 OVR3 OVR1 RELAY OVERRIDE A4- A3- A3+ A4+ +12V +5V shld shld A5+ A5- A6+ A6- A7+ A7- A8+ A8- shld +5V shld 1C 1NC 2NO 3C 3NC 4NO 5C 5NC 6NO 7C 7NC 8NO 8NC 8C 7NO 6NC 6C 5NO 4NC 4C 3NO 2NC 2C 1NO A2- A1- A1+ A2+ 8 8 Extension 8AI8DO OVERRIDE RELAY +12V ADAP-KOOL 7 6 7 6 4 5 3 4 5 3 COMM ERROR 1 2 1 2 POWER R OVR7 OVR8 OFF - AUTO - ON OVR4 OVR5 OVR6 OVR2 OVR3 OVR1 RELAY OVERRIDE A4- A3- A3+ A4+ +12V +5V shld shld A5+ A5- A6+ A6- A7+ A7- A8+ A8- shld +5V shld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o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 4 : 5 3 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 CM CB Hot Surface G V GVO2 V B S h i e l d L A G N IOPS P/N: C20125416 16 CIRCUIT LAYOUT SHOWN FOR REFERENCE (OTHERS AVAILABLE - IN MULTIPLES OF 4) +12 +5 ShldShld 1+ 1- 2+ 2- 3+ 3- 4+ 4- +12 +5 ShldShld 5+ 5- 6+ 6- 7+ 7- 8+ 8- NO ADAP-KOOL AK2-XM 205B No. 080Z0015 Extension 8AI8DO PRESS R Relay Override 1 1 Power Comm Error OFF-AUTO-ON Override Relay OVR 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 OVR 2 OVR 3 OVR 4 OVR 5 OVR 6 OVR 7 OVR 8 NC CNO 2 NC C NO 3 NC CNO 4 NC C NO 5 NC CNO 6 NC CNO 7 NC C NO 8 NC CSW-1 SW-4 SW-2 SW-3 PRESS PRESS 24 VAC/VDC +- G TP-78 LON G B A XM-205B CM-101A +12 +5 ShldShld 1+ 1- 2+ 2- 3+ 3- 4+ 4- +12 +5 ShldShld 5+ 5- 6+ 6- 7+ 7- 8+ 8- NO ADAP-KOOL AK2-XM 205B No. 080Z0015 Extension 8AI8DO PRESS R Relay Override 1 1 Power Comm Error OFF-AUTO-ON Override Relay OVR 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 OVR 2 OVR 3 OVR 4 OVR 5 OVR 6 OVR 7 OVR 8 NC CNO 2 NC C NO 3 NC CNO 4 NC C NO 5 NC CNO 6 NC C NO 7 NC C NO 8 NC C XM-205B VO2 G 2V G1V SERVICE STATUS EM5.3 ENERGY MANAGEMENT DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 4 : 5 8 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 CM CB DATE: SCALE: NONE DRAWN: AK-SC 255 CONTROL SYSTEM - CARD POWER WIRING EMS-10 09/27/11 .. DATE: SCALE: NONE DRAWN: EMS-9 09/27/11 .. DATE: SCALE: NONE DRAWN: VSD BYPASS CONTROL WIRING - LOCATED IN RACK ELECTRICAL PANEL EMS-8 09/27/11 .. DATE: SCALE: NONE DRAWN: CONTROL SYSTEM - CONDENSER CONTROL TERMINATION EMS-7 09/27/11 .. CONTACTOR (TYPICAL) 30 AMPS 1 FAN FUSE POWER CONNECTION L2 L3 L1 FUSE TO FIELD FUSE FAN TYPICAL CONDENSER CONTROL WIRING BY OEM 2 FAN 3 FAN FAN 4 FAN 5 6 FUSE FUSE FUSE FUSE 7 FAN 8 FAN CONTACTOR SPLIT FUSE FUSE NOTES: 1. 2. 24VDC (SEE SHEET-6) POWER SUPPLY CONNECTION NETWORK COMM MODULE 080Z0061 CONTRACTOR TO PROVIDE 3/4" CONDUIT FOR COMMUNICATION WIRING CABLE FROM EACH RACK CONTROLLER TO ASSOCIATED REMOTE CONDENSER. CONTRACTOR TO INSTALL AND TERMINATE NETWORK. NETWORK SHALL BE DAISY CHAINED AND TERMINATED AT BOTH ENDS OF NETWORK. AK2 I/O MODULE 080Z0018 TO NETWORK COMM MODULE 080Z0061 422A AK2 I/O MODULE 080Z0017 DIN RAIL 080Z0290 POWER IOPS POWER SUPPLY PN 080Z0052 (56VA) S h i e l d N E T W O R K A B Vout1 O U T P U T 1 O U T P U T 2 GND Vout2 GND 1-1/2 amp SB 250 VAC VO2 REV 2.3 G N L 1 2 V A C Input Power Fuse: SERVICE ADDRESS STATUS 431 422 101 211 213 441 442 DROPLEG TEMP SENSOR AMBIENT TEMP SENSOR 120 vac Class 1 Wiring 24vdc Address Switches +12+5ShldShld 1+ 1- 2+ 2- 3+ 3- 4+ 4- +12+5ShldShld 5+ 5- 6+ 6- 7+ 7- 8+ 8- NO 1 ADAP-KOOL AK2-XM 205B No. 080Z0015 Extension 8AI8DO PRESS P R E S S R Relay Override 1 1 Power Comm Error OFF-AUTO-ON Override Relay OVR 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 OVR 2 OVR 3 OVR 4 OVR 5 OVR 6 OVR 7 OVR 8 NC C NO 2 NC C NO 3 NC C NO 4 NC C NO 5 NC C NO 6 NC C NO 7 NC C NO 8 NC C SW-1 P R E S S 4 P R E S S 47 6 5 7 6 5 8 0 1 9 8 0 1 9 SERVICE RESET STATUS 3 STATUS 2 SERVICE RESET STATUS 3 STATUS 2 STATUS 1 COMM ERROR POWER STATUS 1 COMM ERROR POWER 33337 6 45 37 6 45 3 7 6 45 7 6 45 SW-4 SW-2 8 0 1 9 228 0 1 9 22 SW-3 8 0 1 9 28 0 1 9 2 No. 080Z0061 AK2-CM 101A ADAP-KOOL No. 080Z0061 AK2-CM 101A ADAP-KOOL COMM TP78 RR PRESS PRESS 24 VAC/VDC +- G TP-78 LON G B AInput AC Output DC 100-240V 24V 2.5A 22.5-29.5V ++--L +-N()() No. 080Z0055 TO VSD / BYPASS PANEL TO V S D / B Y P A S S P A N E L Twisted Pair stranded 22AWG wire with shield. Belden cable no. 8761 or equivalent. Note: There is no polarity requirement on network terminals A and B. The shield must be connected. INSTALL END OF LINE RESISTOR IF NETWORK TERMINATES HERE Output Ratings: 0-10 VDC FROM LOW PRESSURE BUILDING TRANSDUCER FROM SPACE TEMP SENSOR FROM DISCH AIR SENSOR FROM RH SENSOR FROM COMP PROOF #1 FROM COMP PROOF #2 FROM AIR FLOW SWITCH FROM SMOKE DETECTOR TO HEAT STAGE 1 TO HEAT STAGE 2 TO COOL STAGE 1 TO COOL STAGE 2 TO FAN TO REHEAT SOLENOID AK-SC 255 CONTROL SYSTEM - TYPICAL COMBO BOARD Input AC Output DC 100-240V 24V 2.5A 22.5-29.5V ++--L +-N()() No. 080Z0055 I/O MODULE POWER SUPPLY (24 VDC) NOMINAL INPUT VOLTAGE: OUTPUT VOLTAGE: UNIT SHIPPED FOR 230 VAC SUPPLY. 115V 230V I/O POWER SUPPLY (IOPS) 230V GND N 115/230Vac ~ 600/300 mA L TYPE 1 1.0A 250V SB 115V Secondary Primary 12V 24V Da n f o s s POWER STATUS LED (RED) 12/24Vac ~ . IO P S - 3 V e r s i o n 24V 12V 1. 0 GND 5.0A 250V . SB POWER SET JUMPERS W3 & W4 FOR 12 OR 24 VOLTS SEE DETAIL BELOW SET JUMPERS W1 & W2 FOR 115 OR 230 VOLTS SEE DETAIL BELOW 100-240 VAC 45-65 Hz 1.4 A (120 VAC) 0.4 A (240 VAC) 24 VDC +/- 1%%% 2.5 A 60 VA OUTPUT ADJUSTMENT THIS DRAWING REPRESENTS A TYPICAL STORE, AND SERVES AS A TEMPLATE FOR DEVELOPING JOB SPECIFIC DRAWINGS. YOUR DRAWINGS SHALL REFLECT THE DESIGN REQUIREMENTS FOR YOUR SPECIFIC STORE, AND SHALL USE THE LAYOUT ESTABLISHED BY THIS TEMPLATE. USE OF THE TEMPLATE IS NECESSARY TO SUPPORT THE DESIGN, AND PROCUREMENT SYSTEMS WITHIN THE KROGER COMPANY. REFER TO SHEET E1.3.2 FOR STORE SPECIFIC CONTROL POINT CONNECTIONS.. NO 1 ADAP-KOOL AK2-XM 204B No. 080Z0016 Extension 8DO PRESS P R E S S R Relay Override 1 1 Power Comm Error OFF-AUTO-ON Override Relay OVR 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 OVR 2 OVR 3 OVR 4 OVR 5 OVR 6 OVR 7 OVR 8 NC C NO 2 NC C NO 3 NC CNO 4 NC C NO 5 NC C NO 6 NC CNO 7 NC C NO 8 NC C SW-1 P R E S S 4 P R E S S 4765 76 5 8 0 1 9 8 0 1 9 SERVICE RESET STATUS 3 STATUS 2 SERVICE RESET STATUS 3 STATUS 2 STATUS 1 COMM ERROR POWER STATUS 1 COMM ERROR POWER 33337 6 45 37 6 45 3 7 6 45 7 6 45 SW-4 SW-2 8 0 1 9228 0 1 922 SW-3 8 0 1 928 0 1 92 No. 080Z0061 AK2-CM 101A ADAP-KOOL No. 080Z0061 AK2-CM 101A ADAP-KOOL COMM TP78 RR PRESS PRESS 24 VAC/VDC +- G TP-78 LON G B A 2. 1 115V 230V N L 70 - 2 1 6 IO P S V e r s i o n Da n f o s s A u t o m a t i c C o n t r o l s 24V 3 2 1 3 2 1 3 2 1 250V 2.5A 12V GND 12/24VAC ~ GND TYPE 1 SB 3 2 1 115/230V ~ 320/160 mA POWER W1 F2 W4 W3 F1 W2 9 10 5 4 3 6 7 8 2 9 10 5 4 3 6 7 8 2 F2 W4 LD1 D1 R6 MK2 W3 L2 F1 R1 R2 MK1 L1 C2 W2 W1 C1 C3 K A2- A1- A1+ A2+ 88 Extension 8AI8DO OVERRIDE RELAY +12V ADAP-KOOL 7 6 7 6 4 5 3 4 5 3 COMM ERROR 1 2 1 2 POWER R OVR7 OVR8 OFF - AUTO - ON OVR4 OVR5 OVR6 OVR2 OVR3 OVR1 RELAY OVERRIDE A4- A3- A3+ A4+ +12V +5V shld shld A5+ A5- A6+ A6- A7+ A7- A8+ A8- shld +5V shld 1C 1NC 2NO 3C 3NC 4NO 5C 5NC 6NO 7C 7NC 8NO 8NC 8C 7NO 6NC 6C 5NO 4NC 4C 3NO 2NC 2C 1NO EM5.4 ENERGY MANAGEMENT DETAILS FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 5 : 0 3 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 CM CB E 1 2 3 4 D C B A SCALE: 3/32"=1'-0" 1 ET1.1 SYSTEMS PLAN E102 E102 AR E 6 6 AR E 6 6 AR E 6 6 AR E 6 6 AR E 6 6 AR E 6 6 S24 S24 D23T D23T GE38 GE38 (2 ) (2 ) (2 ) (2 ) (2 ) (2 ) (2 ) (2 ) GE102A 4 1 1 1 1 1 8 9 119 ACCT. 118 CUSTOMER SERVICE XXX CHECKLANES 100 SALES 117 MEN 116 WOMEN 114 STORAGE 112 DATA 110 HALL "A" 109 BREAK ROOM 115 HALL "B" 113 OFFICE 108 DAIRY COOLER 105 BACK ROOM 107 ELECTRIC ROOM 106 DELI PREP 103 SEAFOOD PREP 104 MEAT PREP 102 PRODUCE PREP 101 HALL "C" 111 JANITOR'S CLOSET ET1.1 SYSTEMS PLAN FACILITY ENGINEERING K.M.A.: CENTRAL INDIANAPOLIS, IN 46250 5960 CASTLEWAY WEST DR. OWNER 12/08/2014 BID/PERMIT ISSUE TH I S D O C U M E N T I S T H E P R O D U C T A N D E X C L U S I V E P R O P E R T Y O F C O L E + R U S S E L L A R C H I T E C T S , I N C . N E I T H E R T H E D O C U ME N T N O R T H E I N F O R M A T I O N I T C O N T A I N S M A Y BE C O P I E D O R U S E D F O R O T H E R T H A N T H E S P E C I F I C P R O J E CT F O R W H I C H I T W A S P R E P A R E D W I T H O U T T H E E X P L I C I T C ON S E N T O F C O L E + R U S S E L L A R C H I T E C T S , I N C . PL O T T E D : M o n d a y , D e c e m b e r 0 8 , 2 0 1 4 4 : 4 5 : 2 2 P M TENANT FIT-OUT J-959 1215 S. RANGELINE RD CARMEL, IN 46032 515013 SIGNED: 12-08-14 KEY NOTES GENERAL NOTES 1 PROVIDE TELEPHONE AND/OR DATA OUTLET BOX (AS APPLICABLE) FOR COUNTERTOP OR OTHER SPECIAL HEIGHT EQUIPMENT (COUNTERTOP, CASEWORK, ETC.) FOR EACH DEVICE SHOWN. COORDINATE WITH PLUGMOLD WHERE APPLICABLE. COORDINATE SPECIFICS IN FIELD. PROVIDE CONDUIT(S) AS INDICATED IN VOICE/DATA OUTLET SCHEDULE ON THIS SHEET. 2 PROVIDE (1) 1" EMPTY CONCEALED CONDUIT FOR CASH REGISTERS AND COMMUNICATIONS FROM OUTLET BOX UP TO JOIST SPACE. 3 PROVIDE (2) 1" EMPTY SEAL-TIGHT FLEXIBLE CONDUITS FROM TOP OF EACH TELE-POWER POLE TO INSIDE CASEWORK BASE. REFER TO DETAIL ESD-62, ON THE E5 SERIES SHEETS. 4 PROVIDE (2) 1" EMPTY CONDUITS FROM CASHIER STATION TO EACH U-SCAN STATION VIA TELE-POWER POLES. REFER TO DETAIL ESD-62A, ON THE E5 SERIES SHEETS. 5 PROVIDE TELEPHONE AND/OR DATA OUTLET BOX (AS APPLICABLE) AT 1'-6" A.F.F. FOR EACH DEVICE SHOWN, UNLESS OTHERWISE NOTED. PROVIDE CONDUIT(S) AS INDICATED IN VOICE/DATA OUTLET SCHEDULE. 6 PROVIDE DATA CONDUIT DROP TO THEFT DETECTION ELECTRONIC SURVEILLANCE SYSTEM CONTROL BOX AS INDICATED ON DETAIL ESD-52, ON SHEET E5.2. COORDINATE WORK WITH DECOR ELEMENTS AT ALL DOORS IN SALES AND VESTIBULE AREAS. 7 PROVIDE TELEPHONE AND/OR DATA OUTLET BOX AT 48" A.F.F. PROVIDE CONDUIT AS INDICATED IN "VOICE/DATA" OUTLET SCHEDULE. 8 MDF DATA RACK - STUB (2) 3" CONDUITS TO OVERHEAD JOIST SPACE. 9 PROVIDE JUNCTION BOX AT 48" A.F.F. FOR TERMINATION OF SCALE CONDUITS. 10 PROVIDE (1) DUPLEX TELEPHONE OUTLET BOX CONNECTED TO A NON-DEDICATED TELEPHONE LINE WITH WITHIN TWO FEET OF FIRE ALARM CONTROL PANEL FOR BACK-UP CONNECTION TO TELEPHONE SYSTEM. 11 PROVIDE 8'H X 4'W X 3/4"D PLYWOOD EQUIPMENT TELEPHONE TERMINAL BOARD (IDF/TTB) PER SPECIFICATIONS. STUB (2) 3" EMPTY CONDUITS TO OVERHEAD JOIST SPACE. PROVIDE (1) 4" EMPTY CONDUIT FROM ECR ROOM TELEPHONE TERMINAL BOARD TO TELEPHONE TERMINAL BOARD IN REAR OF STORE, ROUTED OVERHEAD. PROVIDE (1) 2" EMPTY CONDUIT FROM TELEPHONE TERMINAL BOARD, ROUTED OVERHEAD, AND TERMINATED IN BAR JOIST SPACE IN BACK ROOM NEAR DOCK RECEIVING DESK FOR SECURITY WIRING. FIELD VERIFY SPECIFICS FOR ALL LOCATIONS AND TERMINATION REQUIREMENTS. TELEPHONE OUTLET, (#) REPRESENTS QUANTITY OF TELEPHONE DEVICES GREATER THAN (1) DATA OUTLET, (#) REPRESENTS QUANTITY OF DATA DEVICES GREATER THAN (1) 3/4" THICK, 4' HIGH, 8FT LENGTH TELEPHONE PLYWOOD BACKBOARD SECURITY SYSTEM KEYPAD JUNCTION BOX CEILING MOUNTED SECURITY CAMERA WALL MOUNTED SECURITY CAMERA WALL MOUNTED DOOR SWITCH S SECURITY SYSTEM SIREN KP PROVIDE EMPTY CONCEALED GALVANIZED STEEL EMT CONDUIT DROP(S) FROM OVERHEADJOIST SPACE TO VOICE/DATA OUTLET BOXES AS DEFINED IN THIS SCHEDULE. PROVIDE INSULATED THROAT FITTINGS (OR BUSHINGS), SWEEP BENDS AND 200 POUND DRAG LINES. PROVIDE 4" SQUARE X 2-1/8" DEEP OUTLET BOX FOR ALL APPLICATIONS. INSTALL FLUSH MOUNTED WHEREVER POSSIBLE. INSTALL AT 18" A.F.F. UNLESS INDICATED OTHERWISE. PROVIDE SINGLE GANG RING FOR UP TO FOUR (4) TOTAL JACKS AND TWO GANG RING FOR UP TO EIGHT (8) JACKS. PROVIDE QUANTITIES OF CONDUIT DROPS AS REQUIRED. QUANTITY OF VOICE/DATA JACKS SERVED MINIMUM CONDUIT SIZE REQUIRED 2 3/4" 4 1" 8 1-1/4" 12 1-1/2" SYSTEMS/SECURITY SYMBOLS XX DRAWING NOTE, XX = DRAWING NOTE DESIGNATION ANNOTATION TELEVISION VOICE/DATA OUTLET SCHEDULE (#) (#) A. ALL RACEWAYS AND BOXES FOR CT DEVICES SHALL BE PROVIDED BY BEC. DEVICES TO BE PROVIDED BY OTHERS. PROVIDE PULL STRINGS AND END BUSHINGS IN ALL RACEWAYS. ALL CONDUIT FOR DATA DROPS STUB UP ABOVE ACCESSIBLE CEILING. B. REFER TO EQUIPMENT SCHEDULE ON E5-SERIES DRAWINGS FOR MOUNTING HEIGHTS AND ADDITIONAL INFORMATION. ALSO SEE DETAILS ON SHEET E5-SERIES DRAWINGS WHERE APPLICABLE. C. ALL DIMENSIONS INDICATED ON PLANS THAT ARE FROM INTERIOR PARTITIONS WHERE THE RETURN AIR SHAFT IS INDICATED ARE TAKEN FROM THE SALES AREA SIDE OF THE ROOF DECK HIGH PARTITION, NOT THE RETURN AIR SHAFT PARTITION. D. COORDINATE THE UNDERSLAB CONDUIT/RACEWAY LAYOUT WITH ALL AFFECTED PARTIES PRIOR TO SLAB PLACEMENT. E. THE FOLLOWING APPLIES FOR ALL KITCHEN AND FOOD PREP TYPE AREAS. INSTALL ALL WALL OUTLETS RECESSED, FLUSH MOUNTED. INSTALL ALL OUTLETS LOCATED ABOVE STAINLESS STEEL TABLES AT 42” AFF. MOUNT ALL WALL OUTLETS IN ALL PREP AREAS HORIZONTALLY. DO NOT INSTALL OUTLETS WHERE GYPSUM BOARD MEETS WALL TILE - EITHER INSTALL FULLY IN GYPSUM BOARD OR IN WALL TILE. F. IN ADDITION TO REQUIREMENTS SET FORTH UNDER NOTE D ABOVE, PROVIDE WEATHERPROOF (NEMA 3R WHILE IN USE) OUTLETS IN PRODUCE PREP AND MEAT PREP. G. REFER TO ELECTRICAL DIMENSION PLANS FOR GENERAL DIMENSIONAL INFORMATION THAT SHALL SCHEMATICALLY APPLY FOR CORRESPONDING SYSTEMS WORK. AM CB PROVIDE (2) 2 INCH CONDUIT PENETRATIONS AT APPROXIMATELY 16 FEET ABOVE FINISHED GRADE. CONDUITS ARE TO BE USED FOR COMMUNICATION PATHWAYS AND SEALED ONCE CABLING SYSTEM IS IN PLACE. COORDINATE EXACT LOCATION OF PENETRATIONS WITH KROGER PM AND T1 CABLE INSTALLER. T1 CONDUIT NOTE