HomeMy WebLinkAboutcomcheck.pdfProject Title: Dr Timothy Towne DC Report date: 12/19/14
Data filename: P:\140188 Dr Tim Towne DC\DOCS\comcheck.cck Page 1 of 2
COMcheck Software Version 3.9.4
Interior Lighting and Power
Compliance Certificate
90.1 (2007) Standard
Section 1: Project Information
Project Type: Alteration
Project Title : Dr Timothy Towne DC
Construction Site: Owner/Agent: Designer/Contractor:
14580 River Road
Carmel, IN
Charles Key
KLC Realty, LLC
3825 S. East Street
Indianapolis, IN 46227
Shawn Curran
Curran Architecture
6925 East 96th Street
Suite 105
Indianapolis, IN 46250
(317)288-0681
scurran@curran-architecture.com
Section 2: Interior Lighting and Power Calculation
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B x C)
Common Space Types:Office - Enclosed 1200 1.1 1320
Total Allowed Watts =1320
Section 3: Interior Lighting Fixture Schedule
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
D
Fixture
Watt.
E
(C X D)
Common Space Types:Office - Enclosed (1200 sq.ft.)
LED 1: LED MR 4W:11 6 5 8 0
Linear Fluorescent 1: 48" T8 32W (Super T8): Electronic: 2 9 85 765
Compact Fluorescent 1: Triple 4-pin 18W: Electronic: 2 1 36 36
Total Proposed Watts =881
Interior Lighting PASSES
Section 4: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and
other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 90.1 (2007) Standard
requirements in COMcheck Version 3.9.4 and to comply with the mandatory requirements in the Requirements Checklist.
Shawn Curran, President
Name - Title Signature Date
Section 5: Post Construction Compliance Statement
Record Drawings and Operating and Maintenance Manuals:
❑1. Construction documents with record drawings and operating and maintenance manuals provided to the owner.
Lighting Designer or Contractor Name Signature Date
Project Title: Dr Timothy Towne DC Report date: 12/19/14
Data filename: P:\140188 Dr Tim Towne DC\DOCS\comcheck.cck Page 2 of 2
COMcheck Software Version 3.9.4
Mechanical Compliance Certificate
90.1 (2007) Standard
Section 1: Project Information
Project Type: Alteration
Project Title : Dr Timothy Towne DC
Construction Site: Owner/Agent: Designer/Contractor:
14580 River Road
Carmel, IN
Charles Key
KLC Realty, LLC
3825 S. East Street
Indianapolis, IN 46227
Shawn Curran
Curran Architecture
6925 East 96th Street
Suite 105
Indianapolis, IN 46250
(317)288-0681
scurran@curran-architecture.com
Section 2: General Information
Building Location (for weather data):Indianapolis, Indiana
Climate Zone:5a
Section 3: Mechanical Systems List
Quantity System Type & Description
1 Water Heater 1:
Electric Storage Water Heater, Capacity: 6 gallons
No minimum efficiency requirement applies
SWH COMPLIANCE REQUIRED.
Section 5: Compliance Statement
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application. The proposed mechanical alteration project has been designed to
meet the 90.1 (2007) Standard, Chapter 8, requirements in COMcheck Version 3.9.4 and to comply with the mandatory requirements in the
Requirements Checklist.
Shawn Curran, President
Name - Title Signature Date
Section 6: Post Construction Compliance Statement
❑HVAC record drawings of the actual installation and performance data for each equipment provided to the owner within 90 days after
system acceptance.
❑HVAC O&M documents for all mechanical equipment and system provided to the owner within 90 days after system acceptance.
❑Written HVAC balancing report provided to the owner.
The above post construction requirements have been completed.
Principal Mechanical Designer-Name Signature Date
12/19/14