Loading...
HomeMy WebLinkAboutA1.1 Construction Plan.PDFProject Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: UN I T E D F I D E L I T Y B A N K Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - B l d g A 72 0 S . R a n g e L i n e R o a d , S u i t e 1 4 0 COPYRIGHT & OWNERSHIP OF DOCUMENTS N D N M M M M M M M M MM M M M M M M M M M M M M M M M M M M TRASH DISP.DA3 Mtr R m 1A - 2 ( A 1 4 8 ) StairSA4 ElevEA12 StairSA3 ElevEA6 StairSA5 StairSA1 ElevEA9 ElevEA8 ElevEA1 StairSA2 StairSA6 ElevEA11 ELEVEA4ELEVEA5 ElevEA3 ElevEA2 ElevEA7 ElevEA10 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. KEY PLAN PEDCOR DESIGN GROUP A1.1 Construction Plan AJR MC2/11/2015 STATE RELEASE SET: 02/11/2015 SUITE 140 N 10'-2 19/64" 21 ' - 1 3 / 4 " 1 A4.1 2 A4.1 FP9 FP5 FP8 FP6 FP7 FP3 FP3 FP2 FP3 FP1 FP12 VAULT SAFE 103 10 6 10 2 108 W2 WAITING AREA 101 SUPPLY ROOM 106 EXISTING RESTROOM 108 OFFICE 103 TELLER 102 M NM.5L.5 24 25 APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 13. 14. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 15. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. REMOVE EXISTING CARPET TILE AS NEEDED TO BUILD NEW WALLS. COVER AND PROTECT ALL OTHER CARPET TILE. REPLACE AND CLEAN ALL CARPET TILE AFTER CONSTRUCTION IS COMPLETE. ALIGN FINISHED FACES. CONSTRUCTION PLAN NOTES: FP1 FP2 FP3 GENERAL CONSTRUCTION NOTES: DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. 1. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION.3. 4. 5. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 6. 7. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 8. 9. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 10. 11. 12. EXISTING PARTITION TO REMAIN NEW WALL PARTITION WALL LEGEND: NOTES: SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. ALL WALLS ARE TO BE W2 UNLESS NOTED OTHERWISE. 2. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL UNLESS NOTED OTHERWISE. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE ARCHITECT FOR REVIEW FOR AESTHETIC PURPOSES ONLY. SEE A4.1 FOR DOOR SCHEDULE. ALL PENETRATIONS IN RATED WALL PARTITIONS AND FLOOR SYSTEMS SHALL BE FIRE RATED ASSEMBLIES. SUBMIT PRODUCT DATA AND ASSEMBLY DRAWINGS WITH TEST FILE NUMBERS FOR REVIEW. USE MOISTURE-MOLD RESISTANT GYPSUM WALLBOARD MEETING ASTM D3273 ON ALL WALL SURFACES IN RESTROOMS. INSULATION FOR INTERIOR WALL APPLICATION SHALL BE FORMALDEHYDE-FREE, UNFACED, GLASS-FIBER BLANKET INSULATION IN BATT FORM CONFORMING TO ASTM C 665, TYPE I, WITH THICKNESS TO BE EQUAL OR GREATER THAN THAT STUD THICKNESS OF THE WALL INTO WHICH IS IT INSTALLED. CENTER WALL ON WINDOW MULLION AS PER BUILDING STANDARD DETAIL. USE SEALANT AT MULLION FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION REFERENCE DETAIL 6/A4.1. PROVIDE AND INSTALL BLOCKING FOR WALL MOUNTED TELEVISION. TELEVISIONS ARE TO BE MOUNTED AT 60" AFF TO THE BOTTOM. VERIFY IN THE FIELD WITH THE TENANT BEFORE LOCATING BLOCKING AND ELECTRICAL FOR TELEVISIONS. 10 0 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. DENOTES AREA NOT IN CONTRACT. 4- 7 / 8 " WALLS TO EXTEND TO STRUCTURAL DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W1 3-5/8" 20 GAUGE METAL STUDS @16" O.C. INSULATION INSIDE WALL. WALLS TO EXTEND TO 11'-6" AFF. PROVIDE 3-5/8" WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W2 3-5/8" 20 GAUGE METAL STUDS @16"O.C. EXISTING DOOR AND FRAME. SEE BUILDING SHELL PLAN. FP6 4- 7 / 8 " REMOVE THE HANDLE ON THE EXTERIOR SIDE OF DOOR.FP4 REMOVE THE EXISTING BUILDING EXPANSION JOINT AND REINSTALL PROPERLY RECESSED IN THE WALL. FP5 PROVIDE OPENING IN EXISTING WALL FOR TENANT NIGHT DEPOSITORY. COORDINATE OPENING SIZE AND LOCATION WITH MFG. INSTALLATION RECOMMENDATION. FP7 PROVIDE BLOCKING IN WALL AS NEEDED FOR TENANT PROVIDED SIGNAGE.FP8 PROVIDE NEW WINDOW TO BE 4’-0” X 7’-0” AT 36” AFF TO THE BOTTOM W/PAINTED HOLOW METAL FRAME AND !” CLEAR TEMPERED GLASS. SEE ELEVATION 5/A4.1 FOR DETAILS. FP9 NOT USED.FP10 NOT USED.FP11 PROVIDE BLACK OUT WINDOW FILM. CONTACT SOLAR CONCEPTS, BILL SWHEAR 317-335-3100.FP12 NEW LOW WALL PARTITION NOT USED.FP13 SCALE: 1/4" = 1'-0" 1 Construction Plan A1.1