Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.3 Reflected Ceiling Plan.PDF
Project Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: UN I T E D F I D E L I T Y B A N K Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - B l d g A 72 0 S . R a n g e L i n e R o a d , S u i t e 1 4 0 COPYRIGHT & OWNERSHIP OF DOCUMENTS N D N M M M M M M M M MM M M M M M M M M M M M M M M M M M M TRASH DISP.DA3 Mtr R m 1A - 2 ( A 1 4 8 ) StairSA4 ElevEA12 StairSA3 ElevEA6 StairSA5 StairSA1 ElevEA9 ElevEA8 ElevEA1 StairSA2 StairSA6 ElevEA11 ELEVEA4ELEVEA5 ElevEA3 ElevEA2 ElevEA7 ElevEA10 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. KEY PLAN PEDCOR DESIGN GROUP A1.3 Reflected Ceiling Plan AJR MC2/11/2015 STATE RELEASE SET: 02/11/2015 SUITE 140 N 5' - 3 7 / 8 " 16'-0"19'-3 11/16" 5' - 3 7 / 8 " OPEN 9'-0" 11'-6" OPEN OPEN CP2 CP4 CP2 CP2 CP5 CP5 CP5 CP3 CP6 CP1 CP7 CP7 CP5 CP8 CP8 N N M NM.5L.5 24 25 OWNER TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. GENERAL CEILING NOTES: CEILING PLAN NOTES: PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. SUPPLY/INSTALL NEW VOICE/DATA CABLE TRAY AS DIRECTED ON REFLECTED CEILING PLAN. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 10. 9. 8. 5. 6. 7. 4. 1. 2. 3. REFLECTED CEILING LEGEND: ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. OWNER TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. LOCATE NEW SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM ARCHITECT AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. CP1 CONTROL LIGHTING FROM THIS LOCATION. HVAC UNITS ARE TO BE LOCATED IN THE STORAGE AREA. CP2 EXISTING OPEN CEILING TO REMAIN. TOUCH UP CEILING PAINT P4 AS NEEDED. TOUCH UP PAINT ON ALL EXPOSED MECHANICAL AND ELECTRICAL ITEMS AS NEEDED. CP3 EXISTING SUSPENDED ACOUSTICAL CEILING TO REMAIN. REPLACE ANY DAMAGED OR STAINED CEILING TILES TO MATCH EXISTING. TWO WAY SWITCH. GYPSUM BOARD CEILING TO BE PAINTED P5. INDICATION DUAL-LITE TO BE: MERCURY LIGHTING MER-ELXTE OR EQUAL. CEILING MOUNTED EXIT LIGHT W/ DIRECTION 2' X 2' SUSPENDED CEILING TO BE ACT1. N PENDANT MOUNTED LIGHT FIXTURE TO BE: ATLANTIC LIGHTING - P-V8-42-BL-C72. LIGHT FIXTURES ARE TO BE MOUNTED AT 13'-0" AFF TO THE BOTTOM OF THE FIXTURE. VERIFY IN THE FIELD. AIR CRAFT CABLE IS TO BE PROVIDED AND TO BE ADJUSTABLE. EXHAUST GRILLE IN CEILING FOR USE WITH BUILDING'S EXHAUST SYSTEM. CP4 EXISTING PAINTED DRYWALL BULKHEAD TO REMAIN. TOUCH UP PAINT AS NEEDED TO BE P5. CP5 EXISTING LIGHT FIXTURES TO REMAIN. REPLACE ANY NON-WORKING LAMPS. ALL LAMPS TO BE THE SAME COLOR TEMPERATURE. EMERGENCY LIGHT. CONFIRM LOCATIONS IN THE FIELD. 11.COORDINATE ALL LIGHTING CIRCUITS WITH THE TENANT. CP6 REMOVE TRACK AND SAVE FOR REUSE. CAP POWER AS NEEDED. CP7 ADD NEW LIGHT FIXTURES WITH AN 'N' TO MATCH EXISTING. TIE NEW LIGHTS INTO EXISTING CIRCUIT AND SWITCH WITH OPEN AREA LIGHTING. CP8 PROVIDE SHED STYLE AWNINGS WITH OPEN ENDS. TENANT LOGO TO BE ON ANGLED SURFACE OF AWNING. SEE SHEET A4.1 FOR DETAILS. M M.5L.5 4 A4.1 6 A4.1 FABRIC AWNING OVER ALUMINUM AWNING TRUSSES, W/ MILL FINISH OVERHEAD NOTE: SUBMIT ATTACHMENT DETAIL FOR CONNECTION OF AWNING FRAME TO WALL STRUCTURE. FABRIC AWNING OVER ALUMINUM AWNING TRUSSES, W/ MILL FINISH OVERHEAD SCALE: 1/4" = 1'-0" 1 Reflected Ceiling Plan A1.3 SCALE: 1/2" = 1'-0" 2 AWNING LAYOUT PLAN A1.3