Loading...
HomeMy WebLinkAboutA1.4 Electrical_Data Plan.PDFProject Number: Revisions: Drawn By Checked ByIssue Date James Robert Stutzman, AIA, NCARB Architecture / Project Management: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: UN I T E D F I D E L I T Y B A N K Ca r m e l , In d i a n a 4 6 0 3 2 Ca r m e l C i t y C e n t e r - B l d g A 72 0 S . R a n g e L i n e R o a d , S u i t e 1 4 0 COPYRIGHT & OWNERSHIP OF DOCUMENTS N D N M M M M M M M M MM M M M M M M M M M M M M M M M M M M TRASH DISP.DA3 Mtr R m 1A - 2 ( A 1 4 8 ) StairSA4 ElevEA12 StairSA3 ElevEA6 StairSA5 StairSA1 ElevEA9 ElevEA8 ElevEA1 StairSA2 StairSA6 ElevEA11 ELEVEA4ELEVEA5 ElevEA3 ElevEA2 ElevEA7 ElevEA10 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. KEY PLAN PEDCOR DESIGN GROUP A1.4 Electrical/Data Plan AJR MC2/11/2015 STATE RELEASE SET: 02/11/2015 SUITE 140 N EP1 EP1 EP1 EP1 EP2 EP2 EP2 EP3 EP4 EP3 GFI DEPOSIT TABLE VAULT SAFE D D D N +72" DED N N DED N N +42" N +42" N +42" N +42" N N N N +66"N +66" N NN D +108" D +108" D +108" D +108" WAITING AREA 101 SUPPLY ROOM 106 EXISTING RESTROOM 108 OFFICE 103 TELLER 102 N DED DED 1 DATA 1 PHONE 3 DATA 1 PHONE 3 DATA M NM.5L.5 24 25 GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 7. 9. 6. 5. 4. 3. DUPLEX WALL OUTLET. DEDICATED CIRCUIT OUTLET.DED CABLE TV OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. VERIFY IN THE FIELD. 8. EP1 PROVIDE NEW ELECTRICAL AND DATA OUTLETS SHOWN WITH AN 'N'. ALL PENETRATIONS THROUGH THE DEMISING WALL BETWEEN THE TENANT AND THE SERVICE CORRIDOR NEED TO BE FIRE RATED. USE WHITE FIRE RATED CAULK. FIRE ALARM SYSTEM SHALL BE COMPATIBLE AND TIED TO THE EXISTING BUILDING FIRE ALARM SYSTEM. SYMBOLS SHOWN WITH A 'D' ARE TO BE REMOVED. PULL WIRES BACK TO MAIN PANEL.EP2 MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR & ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. OWNER TO VERIFY WITH TENANT THERMOSTAT LOCATIONS FOR FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2.ELECTRICAL CONTRACTOR & ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS & ENGINEERED CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. ELECTRICAL JUNCTION BOX EXISTING ELEC/DATA TO BE DEMO'D.D RUN CONDUIT FROM WALL THROUGH FURNITURE TO SURFACE MOUNTED JUNCTION BOXES. COORDINATE IN THE FIELD AFTER FURNITURE INSTALL. EP3 PROVIDE (2) 3/4" CONDUIT W/ SINGLE J-BOXES FOR 110V STUB INTO ROUGH OPENING AND TO ACCESSIBLE CEILING. SEE MFG CUT SHEET. EP4 SCALE: 1/4" = 1'-0" 1 Electrical/Data Plan A1.4