NORTH
FINISH NOTES:
1.PRIOR TO INSTALLATION OF NEW FINISHES CONTRACTOR SHALL INSPECT ALL
SUBSTRATES. IF A SUBSTRATE IS DEEMED UNACCEPTABLE THE CONTRACTOR SHALL TAKE
THE NECESSARY STEPS TO RECTIFY THE SITUATION OR CONTACT THE ARCHITECT WITH
THE CONCERN. PROCEEDING WITH THE INSTALLATION OF FINISHES WILL BE CONSTRUED
THAT THE INSTALLER AND/OR FINISHER HAS ACCEPTED SAID SUBSTRATE. NO CHANGE
ORDER WILL BE ISSUED TO RECTIFY CONCEALED, OR UNSATISFACTORY SUBSTRATE ONCE
FINISH WORK HAS PROCEEDED.
2.PREPARE ALL WALL CONSTRUCTION, NEW AND EXISTING, TO RECEIVE NEW FINISHES AS
PER MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR
ALL FINISHES.
3.FLOORING CONTRACTOR TO LEVEL EXISTING FLOOR PER MANUFACTURER'S
RECOMMENDATION AS REQUIRED TO ACCEPT NEW FLOORING.
4.ALL FLOORING TRANSITIONS SHALL COMPLY WITH ADA GUIDELINES.
5.PAINT ALL EXPOSED METAL SURFACES, SUCH AS GRILLES, FIRE EXTINGUISHER CABINETS,
ETC, WITH ALKYD TYPE PAINT. COLOR TO MATCH ADJACENT SURFACE.
6.CONTRACTOR TO PROVIDE AND INSTALL FLOORING TRANSITIONS AS INDICATED ON
FINISH PLAN. WHERE NONE ARE NOTED, CONTRACTOR TO VERIFY REQUIRED
TYPE/COLOR WITH DESIGNER.
7.FINISHES FOR HOLLOW METAL DOORS AND METAL FRAMES SHALL MATCH WALL COLOR,
SHEEN TO BE SEMI-GLOSS, UNLESS NOTED OTHERWISE.
8.ALL PAINTED SURFACES SHALL RECEIVE A MINIMUM OF ONE BASE COAT AND TWO
FINISH COATS.
9.THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL NEW INTERIOR WALL
AND CEILING FINISHES WILL BE CLASS B MINIMUM, WITH A FLAME SPREAD RATING OF 75
MAXIMUM, AND A SMOKE DEVELOPED INDEX OF 450 MAXIMUM, PER IBC SECTION 803.
10.AT ENTRY, EXISTING BRICK / BRICK VENEER TO REMAIN AS IS, DO NOT PAINT.
FINISH LEGEND:
C1
B1
EX EXISTING VCT TO REMAIN, PATCH AND REPAIR AS REQUIRED FOR DOOR CONSTRUCTION
CARPET 1 - BROADLOOM
MANUFACTURE: MOHAWK GROUP
PATTERN: SOLVE
COLOR: 7975 COGNITION GREY
CARPET 2 - BROADLOOM
MANUFACTURE: MOHAWK GROUP
PATTERN: IN THE LOOP
COLOR: TO BE DETERMINED BY DESIGNER
WOOD FLOORING
MANUFACTURE: SOMERSET HARDWOOD FLOORING
DISTRIBUTION: GILFORD FLOORING
COLLECTION: CHARACTER COLLECTION
CONSTRUCTION: SOLIDPLUS ENGINEERED
COLOR: WALNUT
THICKNESS: 1/2"
SIZE: 5" WIDE PLANKS x VARIOUS LENGTHS FROM 10" TO 78"
GLOSS LEVEL: LOW GLOSS
FINISH PLAN NOTES:
1
2
FLOOR
WALL BASE
WALL
PAINT EXISTING WINDOW MULLIONS, INTERIOR AND EXTERIOR, TO MATCH
EXISTING PEWTER COLOR ON EXISTING BUILDING EXTERIOR FACADE.
COORDINATE COLOR MATCH WITH OWNER. PAINT EXISTING DOOR AND
EXTERIOR AWING FRAME TO MATCH PEWTER COLOR.
NEW FLOOR TRANSITION STRIP
NEW WOOD REDUCER STRIP, BY SOMERSET TO MATCH WOOD FLOORING
NEW BIRCH HARDWOOD WOOD BASE STAINED TO MATCH NEW WOOD FLOOR
SEE BASE PROFILE DETAIL 2/A700
NEW 4" RUBBER COVE BASE
MANUFACTURE: JOHNSONITE
COLOR: TO BE DETERMINED BY DESIGNER
P1 PAINT 1 - SHERWIN WILLIAMS SW7009 PEARLY WHITE, EG-SHEL FINISH
PAINT 2 - SHERWIN WILLIAMS SW7029 AGREEABLE GRAY, EG-SHEL FINISH
PAINT 3 - MATCH EXISTING PEWTER COLOR
COLUMN FINISH = EG-SHEL
WINDOW/DOOR FRAMES FINISH = SEMI-GLOSS
WALLCOVERING 1
MANUFACTURE: MDC WALLCOVERING
PATTERN: ASHANTI SHADOWS
WIDTH: 52/54"
COLOR: MCO1901/4526 FLINT
INSTALLATION: REVERSIBLE HANG / RANDOM MATCH
WALLCOVERING 2
MANUFACTURE: MDC WALLCOVERING
PATTERN: ASHANTI SHADOWS
WIDTH: 52/54"
COLOR: MCO1897/4526 SANDSTONE
INSTALLATION: REVERSIBLE HANG / RANDOM MATCH
B2
P2
P3
WC1
WC2
WD
1111
C2
3
2
EX
WD
C1
C2
C1 C1
B1 P1
B2 P2
B2
P2
B2 B2P2
P2
C1
B2
P2
2
WD B1
WC1
WC2
WC2
WC2
CEILING - SEE A400 SHEET
PAINT 4 - SHERWIN WILLIAMS SW7007 CEILING BRIGHT WHITE, FLAT SHEENP4
3
B2 P2
P3
COLUMN, ALL SIDES
P3
COLUMN, ALL SIDES
11
16
"
312"
1116"
4 1 2 "
BIRCH HARDWOOD, STAINED TO
MATCH WOOD FLOOR
BIRCH HARDWOOD, STAINED TO
MATCH WOOD FLOOR