5RZODQG'HVLJQ,QF
702 North Capitol Avenue
Indianapolis, Indiana 46204
D E S I G N
A R C H I T E C T U R E I N T E R I O R S G R A P H I C S
p 317 636-3980
f 317 263-2073
www.rowlanddesign.com
MERIDIAN MUSIC
CLAY TERRACE
Date:Issue:
TENANT REVIEW2-27-2015
Drawn By:
Scale:
Project Number: 5001-01
CONSTRUCTION DOCUMENTS3-10-2015
SHOWROOM
100
OFFICE
105
HALL
104
TOILET
102
HALL
103
ROOM
101
106
NORTH
ELECTRICAL TELECOMMUNICATION SYMBOL KEY:
REMOVE EXISTING DUPLEX OUTLET (DUE TO DEMOLITION OR EXISTING HEIGHT)
REMOVE EXISTING DATA OUTLET (DUE TO EXISTING HEIGHT)
EXISTING DUPLEX OUTLET TO REMAIN
EXISTING QUAD OUTLET TO REMAIN
EXISTING DATA OUTLET TO REMAIN
NEW DUPLEX OUTLET
NEW DATA OUTLET
NEW DUPLEX OUTLET AT 48"H
NEW JUNCTION BOX FOR FLAT SCREEN MONITOR AT 48"H
REMOVE EXISTING RACK DATA JUNCTION BOX
CONTRACTOR TO VERIFY IF EXISTING WIRING CAN BE REUSED IN NEW
LOCATION
EXISTING OUTLETS AT COUNTER HEIGHT, TO BE RELOCATED OR NEW
AT STANDARD HEIGHT, 18" A.F.F. CENTERLINE OF OUTLET
1
ELECTRICAL PLAN NOTES:
2
ELECTRICAL NOTES:
1.ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL
CODES, ELECTRICAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS, AND
NATIONALLY ACCEPTED CODES AND STANDARDS.
2.ALL WIRE AND CABLE SHALL BE 98% CONDUCTIVITY COPPER, UNLESS OTHERWISE
REQUIRED. WIRE SHALL HAVE 600V RATED THHN/THWN INSULATION.
3.ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. EMT CONDUIT SHALL USE STEEL
COMPRESSION FITTINGS.
4.ALL CONDUITS SHALL HAVE AN EQUIPMENT GROUNDING CONDUCTOR.
5.ALL OUTLET AND DEVICE BOXES SHALL BE SHEET METAL TYPE COMPLYING WITH NEMA
OSI.
6.ALL WIRING DEVICES TO BE SPECIFICATION GRADE BY COOPER, HUBBELL, PASS &
SEYMOUR, OR LEVITRON.
7.ALL DUPLEX RECEPTACLES ARE TO BE 20 AMPERE RATED, NEMA CONFIGURATION 5-20.
8.ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED AT 18" AFF. TO CENTERLINE OF
OUTLET, UNLESS NOTED OTHERWISE.
9.CONTRACTOR TO VERIFY FINISH OF SWITCH PLATES, MONUMENTS, AND ELECTRICAL
COVER PLATES (INCLUDING DATA/TELEPHONE) WITH DESIGNER/ARCHITECT.
10.ALL DIMENSIONS SHOWN ARE TO THE CENTERLINE OF OUTLETS OR GROUPS OF
OUTLETS, UNLESS NOTED OTHERWISE.
11.BACK TO BACK OUTLETS SHALL BE STAGGERED WITH A STUD SEPARATING THEM.
12.PROVIDE EMERGENCY STROBES, HORNS AND/OR OTHER EMERGENCY DEVICES AS
REQUIRED BY STATE AND LOCAL BUILDING CODES. SUBMIT PROPOSED LOCATION
AND PRODUCT FOR DESIGNER REVIEW AND APPROVAL.
13.ANY ABANDONED ELECTRICAL OR COMMUNICATIONS BOXES OR CABLING REMAINING
IN EXISTING WALLS OR FLOOR ARE TO BE REMOVED BACK TO THEIR RESPECTIVE
SOURCES.
14.ALL ENCLOSED AREAS ARE TO BE SWITCHED SEPARATELY.