Loading...
HomeMy WebLinkAboutA810.pdfX X X J 48 J 48 X X X ‹5RZODQG'HVLJQ,QF 702 North Capitol Avenue Indianapolis, Indiana 46204 D E S I G N A R C H I T E C T U R E I N T E R I O R S G R A P H I C S p 317 636-3980 f 317 263-2073 www.rowlanddesign.com MERIDIAN MUSIC CLAY TERRACE Date:Issue: TENANT REVIEW2-27-2015 Drawn By: Scale: Project Number: 5001-01 CONSTRUCTION DOCUMENTS3-10-2015 SHOWROOM 100 OFFICE 105 HALL 104 TOILET 102 HALL 103 ROOM 101 106 NORTH ELECTRICAL TELECOMMUNICATION SYMBOL KEY: REMOVE EXISTING DUPLEX OUTLET (DUE TO DEMOLITION OR EXISTING HEIGHT) REMOVE EXISTING DATA OUTLET (DUE TO EXISTING HEIGHT) EXISTING DUPLEX OUTLET TO REMAIN EXISTING QUAD OUTLET TO REMAIN EXISTING DATA OUTLET TO REMAIN NEW DUPLEX OUTLET NEW DATA OUTLET NEW DUPLEX OUTLET AT 48"H NEW JUNCTION BOX FOR FLAT SCREEN MONITOR AT 48"H REMOVE EXISTING RACK DATA JUNCTION BOX CONTRACTOR TO VERIFY IF EXISTING WIRING CAN BE REUSED IN NEW LOCATION EXISTING OUTLETS AT COUNTER HEIGHT, TO BE RELOCATED OR NEW AT STANDARD HEIGHT, 18" A.F.F. CENTERLINE OF OUTLET 1 ELECTRICAL PLAN NOTES: 2 ELECTRICAL NOTES: 1.ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, ELECTRICAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS, AND NATIONALLY ACCEPTED CODES AND STANDARDS. 2.ALL WIRE AND CABLE SHALL BE 98% CONDUCTIVITY COPPER, UNLESS OTHERWISE REQUIRED. WIRE SHALL HAVE 600V RATED THHN/THWN INSULATION. 3.ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. EMT CONDUIT SHALL USE STEEL COMPRESSION FITTINGS. 4.ALL CONDUITS SHALL HAVE AN EQUIPMENT GROUNDING CONDUCTOR. 5.ALL OUTLET AND DEVICE BOXES SHALL BE SHEET METAL TYPE COMPLYING WITH NEMA OSI. 6.ALL WIRING DEVICES TO BE SPECIFICATION GRADE BY COOPER, HUBBELL, PASS & SEYMOUR, OR LEVITRON. 7.ALL DUPLEX RECEPTACLES ARE TO BE 20 AMPERE RATED, NEMA CONFIGURATION 5-20. 8.ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED AT 18" AFF. TO CENTERLINE OF OUTLET, UNLESS NOTED OTHERWISE. 9.CONTRACTOR TO VERIFY FINISH OF SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES (INCLUDING DATA/TELEPHONE) WITH DESIGNER/ARCHITECT. 10.ALL DIMENSIONS SHOWN ARE TO THE CENTERLINE OF OUTLETS OR GROUPS OF OUTLETS, UNLESS NOTED OTHERWISE. 11.BACK TO BACK OUTLETS SHALL BE STAGGERED WITH A STUD SEPARATING THEM. 12.PROVIDE EMERGENCY STROBES, HORNS AND/OR OTHER EMERGENCY DEVICES AS REQUIRED BY STATE AND LOCAL BUILDING CODES. SUBMIT PROPOSED LOCATION AND PRODUCT FOR DESIGNER REVIEW AND APPROVAL. 13.ANY ABANDONED ELECTRICAL OR COMMUNICATIONS BOXES OR CABLING REMAINING IN EXISTING WALLS OR FLOOR ARE TO BE REMOVED BACK TO THEIR RESPECTIVE SOURCES. 14.ALL ENCLOSED AREAS ARE TO BE SWITCHED SEPARATELY. 1 SHOWROOM 100 HALL 104 TOILET 102 HALL 103 ROOM 101 106 NORTH 22 X 3 3 J 48