HomeMy WebLinkAbout4994-01 - A810 032415.pdf+42 +42 +42 +42 GF +42 GF +42 B B +36 B B +48 +48 +48 +42 +42 +42 +42 B B B +48 DED B+48 DED B DED J DED N NN N N N N N N N N N N NN N NNN N NORTH EXISTING QUAD OUTLET, 18" A.F.F. TO REMAIN ELECTRICAL TELECOMMUNICATION SYMBOL KEY: EXISTING DUPLEX OUTLET, 18" A.F.F. TO REMAIN GFI EXISTING GROUND FAULT DUPLEX OUTLET, (42" A.F.F. /ABOVE BACK SPLASH) UNLESS NOTED OTHERWISE TO REMAIN DED EXISTING DEDICATED DUPLEX OUTLET, 18" A.F.F. TO REMAIN EXISTING TELECOMMUNICATION OUTLET WITH BLANK COVER PLATE. TO REMAIN EXISTING PHONE / DATA OUTLET TO REMAIN ELECTRICAL NOTES: 1.ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, ELECTRICAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS, AND NATIONALLY ACCEPTED CODES AND STANDARDS. 2.ALL WIRE AND CABLE SHALL BE 98% CONDUCTIVITY COPPER, UNLESS OTHERWISE REQUIRED. WIRE SHALL HAVE 600V RATED THHN/THWN INSULATION. 3.ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. EMT CONDUIT SHALL USE STEEL COMPRESSION FITTINGS. 4.ALL CONDUITS SHALL HAVE AN EQUIPMENT GROUNDING CONDUCTOR. 5.ALL OUTLET AND DEVICE BOXES SHALL BE SHEET METAL TYPE COMPLYING WITH NEMA OSI. 6.ALL WIRING DEVICES TO BE SPECIFICATION GRADE BY COOPER, HUBBELL, PASS & SEYMOUR, OR LEVITRON. 7.ALL DUPLEX RECEPTACLES ARE TO BE 20 AMPERE RATED, NEMA CONFIGURATION 5-20. 8.WHERE MORE THAN ONE SWITCH AND/OR OUTLETS OCCURS AT A LOCATION, GANG SWITCHES TOGETHER WITH A COMMON OUTLET BOX AND PROVIDE A SINGLE WALL-PLATE. 9.ALIGN ALL THERMOSTATS VERTICALLY ABOVE SWITCHES AT 60" AFF. COORDINATE WITH MECHANICAL CONTRACTOR. IF A THERMOSTAT IS NEEDED WHERE A SWITCH DOES NOT OCCUR, COORDINATE LOCATION WITH ARCHITECT/DESIGNER. 10.ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED AT 18" AFF. TO CENTERLINE OF OUTLET, UNLESS NOTED OTHERWISE. 11.CONTRACTOR TO VERIFY FINISH OF SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES (INCLUDING DATA/TELEPHONE), TO BE BUILDING STANDARD. 12.ALL DIMENSIONS SHOWN ARE TO THE CENTERLINE OF OUTLETS OR GROUPS OF OUTLETS, UNLESS NOTED OTHERWISE. 13.BACK TO BACK OUTLETS SHALL BE STAGGERED WITH A STUD SEPARATING THEM. 14.PROVIDE EMERGENCY STROBES, HORNS AND/OR OTHER EMERGENCY DEVICES AS REQUIRED BY STATE AND LOCAL BUILDING CODES. 15.ANY ABANDONED ELECTRICAL OR COMMUNICATIONS BOXES OR CABLING REMAINING IN EXISTING WALLS OR FLOOR ARE TO BE REMOVED BACK TO THEIR RESPECTIVE SOURCES. 16.ALL ENCLOSED AREAS ARE TO BE SWITCHED SEPARATELY. SEE SHEET A 400 FOR REFLECTED CEILING PLAN 17.CONTRACTOR IS TO COORDINATE PLACEMENT OF EXIT LIGHTS WITH ENGINEER, FIRE OFFICIAL, AND OWNER. ALL EXIT LIGHTING TO BE BUILDING STANDARD. SEE SHEET A400 T EXISTING THERMOSTAT EXISTING ELECTRICAL PANEL TO REMAIN1 ELECTRICAL PLAN NOTES: ‹5RZODQG'HVLJQ,QF 702 North Capitol Avenue Indianapolis, Indiana 46204 D E S I G N A R C H I T E C T U R E I N T E R I O R S G R A P H I C S p 317 636-3980 f 317 263-2073 www.rowlanddesign.com MERIDIAN MUSIC CARMEL TECHNOLOGY CENTER. BLDG 1 Date:Issue: PRICING RELEASE1-27-2015 Drawn By: Scale: Project Number: 4994-01 CONSTRUCTION RELEASE3-23-2015 B J EXISTING PHONE / DATA JUNCTION BOX WITH SPLIT COVER PLATE. INSTALL NEW BLANK COVER PLATE 1 NEW DUPLEX OUTLET, 18" A.F.F. UNLESS NOTED OTHERWISE N DED N NEW DEDICATED DUPLEX OUTLET, 18" A.F.F. UNLESS NOTED OTHERWISE