CEILING NOTES:
1.THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL CHECK ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF
DUCTWORK, LIGHTING, FIRE PROTECTION, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. PLAN LOCATIONS SHOWN FOR
LIGHTING, DIFFUSERS, SPRINKLER HEADS, ETC. ARE TO ILLUSTRATE DESIGN INTENT. GENERAL CONTRACTOR SHALL COORDINATE FINAL LOCATIONS. ANY CHANGES
OR DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT'S/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE COMMENCEMENT OF NEW WORK.
2.CONTRACTOR SHALL PROVIDE AND INSTALL EXIT SIGNS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. CONTRACTOR SHALL COORDINATE THE
PLACEMENT OF EXIT LIGHTS WITH ENGINEER, FIRE OFFICIAL, AND OWNER. ALL EXIT LIGHTS ARE TO BE BUILDING STANDARD.
3.EXISTING CEILING GRID AND TILE SHALL REMAIN, UNLESS NOTED OTHERWISE. ( see demolition drawing A101) CONTRACTOR IS TO REMOVE AND REPLACE ANY EXISTING
CEILING TILES AND GRID THAT IS DAMAGED (BROKEN, CHIPPED, AND/OR PUNCTURED) WITH NEW TILE AND GRID TO MATCH EXISTING.
4.UNLESS OTHERWISE NOTED, CEILING HEIGHT THROUGHOUT THE SPACE SHALL BE EXISTING HEIGHTS.
5.ALL LIGHT FIXTURE, DIFFUSER, AND SPRINKLER HEAD LOCATIONS ARE PRELIMINARY UNTIL VERIFIED AND COORDINATED BY THE GENERAL CONTRACTOR. CHANGES
MADE TO THIS PLAN MUST BE BROUGHT TO THE ARCHITECT'S/DESIGNER'S ATTENTION PRIOR TO THE COMMENCEMENT OF ANY WORK.
6.SUPPLY AND INSTALL BUILDING STANDARD EMERGENCY LIGHTING UNITS AS REQUIRED BY CODE.
7.SPRINKLER HEAD LOCATIONS AND QUANTITIES TO BE FIELD COORDINATED WITH ELECTRICAL LIGHTING AND MECHANICAL DIFFUSER AND GRILLES. INSTALLATION
SHALL COMPLY WITH ALL APPLICABLE CODES. ANY NEW SPRINKLER HEADS ARE TO MATCH EXISTING.
8.SUPPLY AND INSTALL ALL BUILDING STANDARD STROBES, HORNS AND ALARM PULLS AS REQUIRED BY CODE.
9.USAGE OF FLEXIBLE DUCTING SHALL BE LIMITED TO A MAXIMUM OF 5'-0" FROM THE DIFFUSER. ALL OTHER DUCTING MUST BE SHEET METAL.
CEILING FIXTURE LEGEND
NEW OR RELOCATED 2'X2' BUILDING STANDARD AIR SUPPLY DIFFUSER TO MATCH EXISTING
EXISTING 2'X2' AIR SUPPLY DIFFUSER TO REMAIN
N
NEW OR RELOCATED RETURN AIR GRILL TO MATCH EXISTING
EXISTING RETURN AIR GRILL TO REMAIN
EXISTING EXIT LIGHT TO REMAIN
EXISTING SURFACE MTD EMERGENCY LIGHT TO REMAIN
N
NEW RESTROOM EXHAUST FAN
EXISTING 2'x4' FLUORESCENT FIXTURE TO REMAIN
NEW BUILDING STANDARD 2'x4', LAY-IN FLUORESCENT LIGHT FIXTURE TO MATCH EXISTING.
FIXTURES REMOVED FROM OTHER LOCATIONS MAY BE REUSED IN LIEU OF NEW
NEW OR RELOCATED SURFACE MTD DOUBLE HEAD EMERGENCY LIGHT TO MATCH EXISTINGN
5RZODQG'HVLJQ,QF
702 North Capitol Avenue
Indianapolis, Indiana 46204
D E S I G N
A R C H I T E C T U R E I N T E R I O R S G R A P H I C S
p 317 636-3980
f 317 263-2073
www.rowlanddesign.com
MERIDIAN MUSIC
CARMEL TECHNOLOGY
CENTER. BLDG 1
Date:Issue:
PRICING RELEASE1-27-2015
Drawn By:
Scale:
Project Number: 4994-01
CONSTRUCTION RELEASE3-23-2015
N
NEW OR RELOCATED RETURN AIR GRILL TO MATCH EXISTINGN
N
X1
NEW EXIT LIGHT TO MATCH EXISTINGNXI
EXISTING RECESSED CAN LIGHT TO REMAIN
8'-6" ( EXISTING)
8'-6" ( EXISTING)
8'-6" ( EXISTING)
11'-1" ( EXISTING)
11'-1" ( EXISTING)
TYP
TYP
TYP
TYP
8'-6" ( EXISTING)
TYP
8'-6" ( EXISTING)
EXISTING VAV BOX
AND MAIN SUPPLY
DUCTS TO REMAIN
VAV UNIT
RELOCATE DIFFUSERS
AND FLEXDUCT AS
SHOWN AND
REQUIRED
RELOCATE RETURN AIR GRILLS
AS SHOWN AND REQUIRED
RELOCATE RETURN AIR GRILLS
AS SHOWN AND REQUIRED
RELOCATE RETURN AIR GRILLS
AS SHOWN AND REQUIRED
8'-6" ( EXISTING)
8'-6" ( EXISTING)
8'-6" ( EXISTING)
8'-6" ( EXISTING)
8'-6" ( EXISTING)
8'-6" ( EXISTING)
( EXISTING)
8'-6" ( EXISTING)
8'-6" ( EXISTING)
8'-6" ( EXISTING)
11'-1" ( EXISTING)
11'-1" ( EXISTING)
11'-1" ( EXISTING)
8'-6" ( EXISTING)
8'-6" ( EXISTING)
CLOSET
111
LOUNGE / WAITING
110
REHEARSAL
108
REHEARSAL
107
REHEARSAL
102
ENTRY
101
RECEPTION
124
REHEARSAL
127
BREAK ROOM
126
CO
R
R
I
D
O
R
12
2
OFFICE
123
WOMEN
121
MEN
120
REHEARSAL
103
REHEARSAL
104
REHEARSAL
105
REHEARSAL
106
REHEARSAL
109
REHEARSAL
128
CORRIDOR
125
REHEARSAL
117
REHEARSAL
118
REHEARSAL
119
CLOSET
130
REHEARSAL
131
REHEARSAL
116
REHEARSAL
112
REHEARSAL
113
REHEARSAL
114
CORRIDOR
115
RECITAL
129
PLAN NOTES
1 EXISTING 2'X2' CEILING GRID WITH NEW CEILING TILE IN THIS AREA
2 EXISTING 2'X2' CEILING GRID WITH EXISTING CEILING TILE IN THIS AREA
11 1 1
1111
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
NEW RECESSED CAN LIGHT. FIXTURES REMOVED FROM OTHER LOCATIONS MAY BE REUSED IN
LIEU OF NEW
N
TR
TR
NEW LIGHT TRACK W/ HEADS. BRUCK LIGHTING (OR EQUAL) ECO SERIES WHITE TRACK WITH
Z15 LED TRACK HEADS, 3500 K, WHITE FINISH