Loading...
HomeMy WebLinkAbout4994-01 A400 032415.pdfN N N NN N N N N N N N N N N N N N N N N N N N N N N N N N N NX1 N N N NN N NN NNNN N N N N NNN N N N N NX1 N N N N N NN N N N N NNN N N N TR N TR TR TR TR N NNN NORTH CEILING NOTES: 1.THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL CHECK ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, FIRE PROTECTION, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. PLAN LOCATIONS SHOWN FOR LIGHTING, DIFFUSERS, SPRINKLER HEADS, ETC. ARE TO ILLUSTRATE DESIGN INTENT. GENERAL CONTRACTOR SHALL COORDINATE FINAL LOCATIONS. ANY CHANGES OR DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT'S/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE COMMENCEMENT OF NEW WORK. 2.CONTRACTOR SHALL PROVIDE AND INSTALL EXIT SIGNS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. CONTRACTOR SHALL COORDINATE THE PLACEMENT OF EXIT LIGHTS WITH ENGINEER, FIRE OFFICIAL, AND OWNER. ALL EXIT LIGHTS ARE TO BE BUILDING STANDARD. 3.EXISTING CEILING GRID AND TILE SHALL REMAIN, UNLESS NOTED OTHERWISE. ( see demolition drawing A101) CONTRACTOR IS TO REMOVE AND REPLACE ANY EXISTING CEILING TILES AND GRID THAT IS DAMAGED (BROKEN, CHIPPED, AND/OR PUNCTURED) WITH NEW TILE AND GRID TO MATCH EXISTING. 4.UNLESS OTHERWISE NOTED, CEILING HEIGHT THROUGHOUT THE SPACE SHALL BE EXISTING HEIGHTS. 5.ALL LIGHT FIXTURE, DIFFUSER, AND SPRINKLER HEAD LOCATIONS ARE PRELIMINARY UNTIL VERIFIED AND COORDINATED BY THE GENERAL CONTRACTOR. CHANGES MADE TO THIS PLAN MUST BE BROUGHT TO THE ARCHITECT'S/DESIGNER'S ATTENTION PRIOR TO THE COMMENCEMENT OF ANY WORK. 6.SUPPLY AND INSTALL BUILDING STANDARD EMERGENCY LIGHTING UNITS AS REQUIRED BY CODE. 7.SPRINKLER HEAD LOCATIONS AND QUANTITIES TO BE FIELD COORDINATED WITH ELECTRICAL LIGHTING AND MECHANICAL DIFFUSER AND GRILLES. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CODES. ANY NEW SPRINKLER HEADS ARE TO MATCH EXISTING. 8.SUPPLY AND INSTALL ALL BUILDING STANDARD STROBES, HORNS AND ALARM PULLS AS REQUIRED BY CODE. 9.USAGE OF FLEXIBLE DUCTING SHALL BE LIMITED TO A MAXIMUM OF 5'-0" FROM THE DIFFUSER. ALL OTHER DUCTING MUST BE SHEET METAL. CEILING FIXTURE LEGEND NEW OR RELOCATED 2'X2' BUILDING STANDARD AIR SUPPLY DIFFUSER TO MATCH EXISTING EXISTING 2'X2' AIR SUPPLY DIFFUSER TO REMAIN N NEW OR RELOCATED RETURN AIR GRILL TO MATCH EXISTING EXISTING RETURN AIR GRILL TO REMAIN EXISTING EXIT LIGHT TO REMAIN EXISTING SURFACE MTD EMERGENCY LIGHT TO REMAIN N NEW RESTROOM EXHAUST FAN EXISTING 2'x4' FLUORESCENT FIXTURE TO REMAIN NEW BUILDING STANDARD 2'x4', LAY-IN FLUORESCENT LIGHT FIXTURE TO MATCH EXISTING. FIXTURES REMOVED FROM OTHER LOCATIONS MAY BE REUSED IN LIEU OF NEW NEW OR RELOCATED SURFACE MTD DOUBLE HEAD EMERGENCY LIGHT TO MATCH EXISTINGN ‹5RZODQG'HVLJQ,QF 702 North Capitol Avenue Indianapolis, Indiana 46204 D E S I G N A R C H I T E C T U R E I N T E R I O R S G R A P H I C S p 317 636-3980 f 317 263-2073 www.rowlanddesign.com MERIDIAN MUSIC CARMEL TECHNOLOGY CENTER. BLDG 1 Date:Issue: PRICING RELEASE1-27-2015 Drawn By: Scale: Project Number: 4994-01 CONSTRUCTION RELEASE3-23-2015 N NEW OR RELOCATED RETURN AIR GRILL TO MATCH EXISTINGN N X1 NEW EXIT LIGHT TO MATCH EXISTINGNXI EXISTING RECESSED CAN LIGHT TO REMAIN 8'-6" ( EXISTING) 8'-6" ( EXISTING) 8'-6" ( EXISTING) 11'-1" ( EXISTING) 11'-1" ( EXISTING) TYP TYP TYP TYP 8'-6" ( EXISTING) TYP 8'-6" ( EXISTING) EXISTING VAV BOX AND MAIN SUPPLY DUCTS TO REMAIN VAV UNIT RELOCATE DIFFUSERS AND FLEXDUCT AS SHOWN AND REQUIRED RELOCATE RETURN AIR GRILLS AS SHOWN AND REQUIRED RELOCATE RETURN AIR GRILLS AS SHOWN AND REQUIRED RELOCATE RETURN AIR GRILLS AS SHOWN AND REQUIRED 8'-6" ( EXISTING) 8'-6" ( EXISTING) 8'-6" ( EXISTING) 8'-6" ( EXISTING) 8'-6" ( EXISTING) 8'-6" ( EXISTING) ( EXISTING) 8'-6" ( EXISTING) 8'-6" ( EXISTING) 8'-6" ( EXISTING) 11'-1" ( EXISTING) 11'-1" ( EXISTING) 11'-1" ( EXISTING) 8'-6" ( EXISTING) 8'-6" ( EXISTING) CLOSET 111 LOUNGE / WAITING 110 REHEARSAL 108 REHEARSAL 107 REHEARSAL 102 ENTRY 101 RECEPTION 124 REHEARSAL 127 BREAK ROOM 126 CO R R I D O R 12 2 OFFICE 123 WOMEN 121 MEN 120 REHEARSAL 103 REHEARSAL 104 REHEARSAL 105 REHEARSAL 106 REHEARSAL 109 REHEARSAL 128 CORRIDOR 125 REHEARSAL 117 REHEARSAL 118 REHEARSAL 119 CLOSET 130 REHEARSAL 131 REHEARSAL 116 REHEARSAL 112 REHEARSAL 113 REHEARSAL 114 CORRIDOR 115 RECITAL 129 PLAN NOTES 1 EXISTING 2'X2' CEILING GRID WITH NEW CEILING TILE IN THIS AREA 2 EXISTING 2'X2' CEILING GRID WITH EXISTING CEILING TILE IN THIS AREA 11 1 1 1111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 NEW RECESSED CAN LIGHT. FIXTURES REMOVED FROM OTHER LOCATIONS MAY BE REUSED IN LIEU OF NEW N TR TR NEW LIGHT TRACK W/ HEADS. BRUCK LIGHTING (OR EQUAL) ECO SERIES WHITE TRACK WITH Z15 LED TRACK HEADS, 3500 K, WHITE FINISH