HomeMy WebLinkAbout610_3550_LD300.pdfSCONCE TYPE WS1 / WS2. SIZE VARIES
BASED ON FIXTURE TYPE.
TEXTURED NICHIHA PANEL
CONDUIT
RECESSED JUNCTION BOX
WOOD BLOCKING WRAPPED IN
ALUMINUM
NOTE:
1. REFER TO ARCHITECTURAL DETAILS
FOR SPECIFICS ON INTEGRATION OF
FLASHING, BLOCKING AND JUNCTION
BOXES.
2. NOTE THAT 2X4 FRAMING MUST BE
ADJUSTED BY THE G.C. TO AVOID
J-BOX CONFLICTS AND TO ALLOW
FOR PROPER FEEDING OF WS1 AND
WS2 FIXTURES.
FLASHING
BOTTOM CHORD OF TRUSS
TRUSS WEBBING
TYPE LS1 / LS7 SURFACE MOUNTED TO UNISTRUT
NOTE: E.C. IS RESPONSIBLE FOR PROVIDING ALL
MOUNTING HARDWARE, CONDUIT FEEDS, CABLE
CONNECTORS, AND OTHER ACCESSORIES AS
NEEDED. COORDINATE INSTALLATION WITH THE G.C.
REFERENCE ARCHITECTURAL DETAILS FOR
ADDITIONAL INFORMATION.
UNISTRUT (BEYOND) MOUNTED AT TWO LOCATIONS
ALONG FIXTURE
FEED WIRE CONCEALED WITHIN UNISTRUT
MOUNTING HARDWARE TO SECURE UNISTRUT TO
TRUSS
UNISTRUT MOUNTED TO BOTTOM OF TRUSS
TYPE LS2-5 MOUNTED TO UNISTRUT
BOTTOM CHORD OF TRUSS BEYOND
MOUNTING HARDWARE TO SECURE UNISTRUT TO
TRUSS
NOTE: E.C. IS RESPONSIBLE FOR PROVIDING ALL
MOUNTING HARDWARE, CONDUIT FEEDS, CABLE
CONNECTORS, AND OTHER ACCESSORIES AS
NEEDED. COORDINATE INSTALLATION WITH THE G.C.
REFERENCE ARCHITECTURAL DETAILS FOR
ADDITIONAL INFORMATION.
FEED WIRE CONCEALED WITHIN UNISTRUT
TYPE LR1-3 FIXTURE
BOTTOM OF LENS SITS FLUSH WITH
SURROUNDING FINISHED CEILING
FINISHED CEILING
SKIM COAT APPLIED OVER FIXTURE
SPACKLE FLANGE. APPLICATION
SHALL BE CLEAN AND SEAMLESS,
MATCHING THE SURROUNDING
FINISHED CEILING AS SPECIFIED BY
THE ARCHITECT. E.C. AND G.C. TO
COORDINATE.
FRAMING AS NEEDED TO SUPPORT
DRYWALL. E.C. TO COORDINATE
INSTALLATION AND CEILING
FRAMING AROUND FIXTURES WITH
G.C. AS TO ALLOW FOR
CONTINUOUS RUNS OF FIXTURES
AS SHOWN ON THE DRAWINGS.
THREADED ROD TO STRUCTURE
ABOVE
MOUNTING SCREWS AS NEEDED TO
ATTACH DRYWALL TO FRAMING
SPACKLE FLANGE SECURED TO
FRAMING
Ä
CL
WALL
BOTTOM CHORD OF TRUSS. NOTE: E.C. IS
RESPONSIBLE FOR PROVIDING ALL MOUNTING
HARDWARE AND COORDINATING INSTALLATION
WITH ARCHITECTURAL DETAILS AND G.C.
TYPE DL2 SURFACE MOUNTED TO JUNCTION BOX
TRUSS WEBBING
MC CABLE RUNNING ALONG TOP OF BOTTOM
TRUSS CHORD
JUNCTION BOX MOUNTED TO BOTTOM OF
BOTTOM TRUSS CHORD
NOTE: E.C. IS RESPONSIBLE FOR PROVIDING ALL
MOUNTING HARDWARE, CONDUIT FEEDS, CABLE
CONNECTORS, AND OTHER ACCESSORIES AS
NEEDED. COORDINATE INSTALLATION WITH THE G.C.
REFERENCE ARCHITECTURAL DETAILS FOR
ADDITIONAL INFORMATION.
NOTE:
1.
2.
E.C. IS RESPONSIBLE FOR PROVIDING ALL
MOUNTING HARDWARE, CONDUIT FEEDS,
CABLE CONNECTORS, AND OTHER
ACCESSORIES AS NEEDED. COORDINATE
INSTALLATION WITH THE G.C. REFERENCE
ARCHITECTURAL DETAILS FOR ADDITIONAL
INFORMATION.
FIXTURES SHALL BE CENTERED BETWEEN
TRUSSES.
%'+.+0)
,70%6+10$1:/1706'&61%'+.+0)
56'/
%10&7+6
6;2'&.(+:674'56'//1706'&(41/
%'+.+0)
#.+)0
$1661/%*14&1(64755
LD300
ISSUED FOR 50 %
ISSUED FOR REDLINE REVIEW
ISSUED FOR CONSTRUCTION
ISSUED FOR PERMIT
KICK OFF MEETING
FINAL APPROVED PLAN
ISSUED FOR BID
GETGO, LLC.
SPCR
NO.
REV.
NO.
--
KAB
3550
THE BRIDGES
CARMEL, INDIANA02/27/15
02/24/15
02/27/15
--
01/23/15
--
02-27-15
AS NOTED
BEA
TYPE E1 SECTION DETAIL NOT USED TYPE LS1 / LS7 SECTION DETAIL TYPE LS2-5 SECTION DETAIL
TYPE DL1 SECTION DETAIL TYPE DL2 SECTION DETAIL TYPE LR1-3 SECTION DETAIL
3"=1'-0"73"=1'-0"61"=1'-0"5
3"=1'-0"43"=1'-0"33"=1'-0"23"=1'-0"1
NOT USED
3"=1'-0"8