HomeMy WebLinkAbout410_3550_P203.pdfFLOOR AND SUB-FLOOR 18" 12" 6" AS SHOWN ON DWG'S OR PIPE SIZE AND MATERIAL PEA GRAVEL SPECS. BACKFILL & BEDDING: BELOW GRADE VAPOR RECOVERY TRENCH DETAIL FK-P-022 SCALE: N.T.S. DRAWING NUMBER DATE REVISIONS REMARKS SCALE: N.T.S. DRAWING NUMBER DATE REVISIONS REMARKS VAPOR RECOVERY VENT THRU ROOF FK-P-021 & FLASHING DRAW BAND WITH SEALANT STORM COLLAR ROOF CONE 4" PVC. ALUMINUM DUCTWORK METABESTOS TYPE "B" GRAVITY VENT CAP. TERMINATE AT 3'-0" ABOVE ROOF. MAINTAIN A MINIMUM CLEARANCE OF 10'-0" FROM ALL OUTSIDE AIR INTAKES. NOTE: AVOID ROOF JOISTSROUTE PVC TO 2" CLEARANCE THIMBLE REFER TO PLANSFOR CONTINUATION AND SIZE PROVIDE TRANSITION PIECE FROM PVC TO ALUMINUM (SEE PLAN) TRENCH SCALE: N.T.S. DRAWING NUMBER DATE REVISIONS REMARKS FK-P-024 TYPICAL BEVERAGE EQUIPMENT FW MANIFOLD FW WALL 1 {CODED NOTES: }ROUTE 1" FW PIPING DOWN TIGHT TO WALL. COORDINATE THE EXACT LOCATION WITH GETGO CONSTRUCTION MANAGER. TWO(2) SIOUX CHIEF COPPER MANIFOLD #672XV1010 WITH TEN(10) 1/2" BALL VALVE BRANCHES 2" ON CENTER FOR PEX PIPING CONNECTIONS. BACKFLOW PREVENTER, WATTS NO. SD-3 WITH WATTS BRASS STRAINER 777SI REPLACING THE PLASTIC STRAINER PROVIDED WITH THE SD-3. CONFIRM WITH LOCAL PLUMBING INSPECTOR TO VERIFY WHICH PIECES OF BEVERAGE EQUIPMENT REQUIRE ATMOSPHERIC DRAIN VALVES (TYPICALLY THE CARBONATOR PUMPS). PROVIDE WATTS NO. SD-2 DOUBLE CHECK (NO ATMOSPHERIC DRAIN) TYPE BACKFLOW PREVENTER FOR ANY EQUIPMENT THE LOCAL INSPECTORS GRANTS PERMISSION TO INSTALL THE SD-2 INSTEAD OF THE SD-3. EXTEND 1/4" FLEXIBLE COPPER DRAIN TUBING FROM BACKFLOW PREVENTER RELIEF TO NEW MOP SINK IN THE KITCHEN STORAGE WITH AIR GAP. 3/8" PEX PIPING (1/2" FW PEX FOR FCB MACHINES CARBONATOR PUMPS), ZIP TIE PIPING TOGETHER AND RUN ABOVE CEILING TO BEVERAGE BAR EQUIPMENT. SUPPORT PEX PIPING WITH CLEVIS HANGERS WITH METAL SADDLE ANCHORED FROM ROOF JOIST. ROUTE PEX GROUP PIPING DOWN BEVERAGE BAR WALL AND INTO CABINET SPACE. MOUNT PEX GROUP PIPING AND RUN HORIZONTALLY ALONG THE BACK OF THE CABINET NO LESS THEN 28" ABOVE FINISHED FLOOR AND ROUTE TO EACH PIECE OF BEVERAGE BAR EQUIPMENT. PROVIDE BRONZE SHUT-OFF VALVE DIRECTLY BELOW BEVERAGE EQUIPMENT IN MILLWORK. PLASTIC SHUT-OFF VALVE IS NOT PERMITTED. 3/8" MALE FLARE FITTING. FILTERED WATER CONNECTION TO BEVERAGE EQUIPMENT. FILTERED WATER PIPING (INDICATED FOR TWO(2) PIECES OF BEVERAGE EQUIPMENT). CONFIRM QUANTITY REQUIRED WITH BEVERAGE EQUIPMENT. SPARE MILLWORK BASE 8TYP. 10 TYP. 2TYP. WALL 6 TY P . 9TYP. COUNTER TYP. 11 5 SCALE: N.T.S. DRAWING NUMBER DATE REVISIONS REMARKS FK-P-026 OIL/GREASE CONTAINMENT TANK UNIT DETAIL {NOTES:} A.