HomeMy WebLinkAbout410_3550_P203.pdfFLOOR AND
SUB-FLOOR
18"
12"
6"
AS SHOWN ON DWG'S OR PIPE SIZE AND MATERIAL
PEA GRAVEL
SPECS.
BACKFILL & BEDDING:
BELOW GRADE VAPOR RECOVERY TRENCH DETAIL
FK-P-022
SCALE: N.T.S.
DRAWING NUMBER
DATE
REVISIONS
REMARKS SCALE: N.T.S.
DRAWING NUMBER
DATE
REVISIONS
REMARKS
VAPOR RECOVERY VENT THRU ROOF
FK-P-021
& FLASHING
DRAW BAND WITH SEALANT
STORM COLLAR
ROOF CONE
4" PVC.
ALUMINUM
DUCTWORK
METABESTOS TYPE "B"
GRAVITY VENT CAP.
TERMINATE AT 3'-0"
ABOVE ROOF.
MAINTAIN A MINIMUM
CLEARANCE OF 10'-0"
FROM ALL OUTSIDE
AIR INTAKES.
NOTE:
AVOID ROOF JOISTSROUTE PVC TO
2" CLEARANCE THIMBLE
REFER TO PLANSFOR CONTINUATION
AND SIZE
PROVIDE TRANSITION
PIECE FROM PVC TO
ALUMINUM
(SEE PLAN)
TRENCH
SCALE: N.T.S.
DRAWING NUMBER
DATE
REVISIONS
REMARKS
FK-P-024
TYPICAL BEVERAGE EQUIPMENT FW MANIFOLD
FW
WALL
1
{CODED NOTES:
}ROUTE 1" FW PIPING DOWN TIGHT TO WALL. COORDINATE THE EXACT LOCATION WITH GETGO CONSTRUCTION MANAGER.
TWO(2) SIOUX CHIEF COPPER MANIFOLD #672XV1010 WITH TEN(10) 1/2" BALL VALVE BRANCHES 2" ON CENTER FOR PEX PIPING CONNECTIONS.
BACKFLOW PREVENTER, WATTS NO. SD-3 WITH WATTS BRASS STRAINER 777SI REPLACING THE PLASTIC STRAINER PROVIDED WITH THE SD-3.
CONFIRM WITH LOCAL PLUMBING INSPECTOR TO VERIFY WHICH PIECES OF BEVERAGE EQUIPMENT REQUIRE ATMOSPHERIC DRAIN VALVES
(TYPICALLY THE CARBONATOR PUMPS). PROVIDE WATTS NO. SD-2 DOUBLE CHECK (NO ATMOSPHERIC DRAIN) TYPE BACKFLOW PREVENTER FOR
ANY EQUIPMENT THE LOCAL INSPECTORS GRANTS PERMISSION TO INSTALL THE SD-2 INSTEAD OF THE SD-3.
EXTEND 1/4" FLEXIBLE COPPER DRAIN TUBING FROM BACKFLOW PREVENTER RELIEF TO NEW MOP SINK IN THE KITCHEN STORAGE WITH AIR GAP.
3/8" PEX PIPING (1/2" FW PEX FOR FCB MACHINES CARBONATOR PUMPS), ZIP TIE PIPING TOGETHER AND RUN ABOVE CEILING TO BEVERAGE BAR
EQUIPMENT. SUPPORT PEX PIPING WITH CLEVIS HANGERS WITH METAL SADDLE ANCHORED FROM ROOF JOIST.
ROUTE PEX GROUP PIPING DOWN BEVERAGE BAR WALL AND INTO CABINET SPACE.
MOUNT PEX GROUP PIPING AND RUN HORIZONTALLY ALONG THE BACK OF THE CABINET NO LESS THEN 28" ABOVE FINISHED FLOOR AND ROUTE
TO EACH PIECE OF BEVERAGE BAR EQUIPMENT.
PROVIDE BRONZE SHUT-OFF VALVE DIRECTLY BELOW BEVERAGE EQUIPMENT IN MILLWORK. PLASTIC SHUT-OFF VALVE IS NOT PERMITTED.
3/8" MALE FLARE FITTING.
FILTERED WATER CONNECTION TO BEVERAGE EQUIPMENT.
FILTERED WATER PIPING (INDICATED FOR TWO(2) PIECES OF BEVERAGE EQUIPMENT). CONFIRM QUANTITY REQUIRED WITH BEVERAGE
EQUIPMENT.
SPARE
MILLWORK BASE
8TYP.
10 TYP.
2TYP.
WALL
6
TY
P
.
9TYP.
COUNTER
TYP.
11
5
SCALE: N.T.S.
DRAWING NUMBER
DATE
REVISIONS
REMARKS
FK-P-026
OIL/GREASE CONTAINMENT TANK UNIT DETAIL
{NOTES:}
A.