HomeMy WebLinkAbout 0078.00 MiscellaneousS C HjUILILIE"R•
1993 MEC OVERALL BUILDING Uo COMPLIANCE
Date:
November 05 1998
Building File:
CEN2316.BLG
Home Builder:
CENTEX HOMES
Weather Site:
Indianapolis, IN
Model Name or Number:
2316
Degree Days, H/C:
5653/378
Insulation Contractor.
OVERHEAD DOOR INSUL. DIV
Energy Costs:
Indiana Gas
Contractor's Telephone:
317-842-7444
Elements
Roofs/Ceilings(U-Value)
Above -Grade Walls,(U-Value):
Basement Walls (U-Value):
Insulation Levels
1993 MEC As Designed
0.028
0.026
0.131
0.096
0.088
0.081
OVERALL Uo: 0.099 0.075
This home meets the overall thermal performance requirements of the 1993 Model Energy Code
based on 5653 heating degree-days. (Section 502, Model Energy Code, 1993 edition).
1;
Building Elements
Cavity Ins.
Contin. Ins
Frame
R-Value
R-Value
Spacing
Uo
Area
a- Roof/Ceilings
Roof
38.0
0.0
24.0" o.c.
0.025
811.1
Roof
38.0
0.0
24.0" o.c.
0.027
414:8'
Above-GradeWalls
Wall
13.0
4.9
Wood, 2x4, 16" o.c.
0.056
2399.2'
Joist
13.0
0.0
n/a
0.061
162.8
Window
n/a
n/a
n/a
0.460
62.8
Window
n/a
n/a
n/a
0.460
62.8
Window
n/a
n/a
n/a
0.460
125.5
Door
n/a
2.0
n/a
0.372
40.0
^+ Basement Walls
Wall
0.0
10.0
None
0.081
162.8
Schuller International, Inc. Building Insulation Division P.O. Box 5108 Denver, CO 80217.5105.
For Information on the Performance Home Total Insulation System, call 1-800-654-3103.
This Information does not constitute any vrarranty of energy cost or savings.
REWGold v2.33 (c)l 996 Architectural Energy Corporation,, Boulder, CO.
SIC HIUILILIE.1R
BUILDING FILE REPORT
Builder's File: CEN2316.BLG Date: November 05 1998 Page
Builder Information
' Home"BullderName:
Model Name or Number:
Development Name:
Property Address:
''Energy Analysis Info
,-insulation Contractor Name:
7 Telephone Number:
Building Plan Date:
General Design Characteristics
House Type:
Foundation Type:
Conditioned Floor Area:
Number of Bedrooms:
Conditioned Floor Area Over Garage:
CENTEX HOMES
2316
BLUEPRINT
OVERHEAD DOOR INSUL. DIV.
317-842-7444
10/11/98/
Two Stories
Slab
2362.00
4
0.00 % Of Total Floor Area
i
I
Heated
Basement
First
Level
Mid
Level
Second
Level
Third
Level
Distribution of Cond Floor Area(%)
51.0
49.0
Characteristics of Each Floor
Heated
Basement
First,
Level
Mid
Level
Second
Level
Third
Level
Number of Comers
l
10
8
Percent Open to Floor Above
3.0
0.0
Nominal Flat Ceiling Height
9.0
8.0
Percent Cathedral Ceiling
0.0
0.3
Schuller International, Inc. Building Insulation Division P.O. Box 5108 Denver, CO 802175108.
For Information on the Performance Home Total Insulation System, call 1500-654-3103.
This Information does not constitute any warranty of energy cost or savings.
REM/Gold v2.33 (c)l996 Architectural Energy Corporation, Boulder, CO.
BUILDING FILE REPORT
Page 2
6.BLG
:._
yBuiltlng Envelope Characteristics
Specify below...
4
Ins111ation Level
38.0
;t
--Ceiling(AtticAbove):
38.0
'Cathedral Ceiling:
13.0
+ ``
Rim/Band Joist:
13.0
Frame Wall(Frame Cavity):
Frame Wall(Continuous):
4.9
0.0
i,;
Masonry Wall:
0.0
'" Foundation Wall(Cavity):
10.0
Foundation Wall(Continous):
19 0
Frame Floor:
FLEX DUCT R•5
Duct:
1.00
Infiltration Rate(ACH):
Wall Construction, Type:
Frame
Double - Vinyl
1
Window Type
0.46
Window U-Value:
0.57
Window SHGC:
251.0 square feet
Window Area(excluding fnd walls):
2
Number of Non -Glass Exterior Doors:
Average Slab Depth Below Grade 0.0
Basement: 1 0
First Level:
ut
Mec7Typei
stems Characterstics Fuel -fired air distribution
Hem Type: Gas
HType: Air conditioner
Cem Type: Attic -under insul
Dn: Gas
Dt Water Fuel Type:
4.
Schuller Intemational• Inc. Building_ insulation omsion.P:O: Box 5106 Denver, CO 80217S10B.
For Information on the Performance. Home Total insulationsystem coat or sacall i D.-654 3103
of
This information does not constitute any warranty Boulder, CO.
REM1Gold � (0)1996 Archdectural Energy corporation,