Loading...
HomeMy WebLinkAbout 0087.00 Sewer/Water Permit/sCLAY TOWNSHIP REGIONAL WASTE DISTRICT s SANITARY SEWER PERMIT' ]'Conditional Permit 0 Final Permit 1. INDIVIDUAL LOTS/EXISTING BUILDINGS Project Title:: q , A , /� �y4tiA Vic✓ '- V f a"i' I t/ l Location: Piat'S (� n P ,. b, Lot # I U g Street; address ' [�{ u� CityU Zip:__ `1 County: / Interceptor Charges Paid• LOC EDU Fee 00 PLEASE NOTE: Installation of building sewershall be per the specifications of the Clay Township Regional Waste District (see reverse) and any conditionsnoted,below. All,installations`shall be inspected by District personnel during "open,trench",phase and'before backfilling with sand orstone to six'inches above the pipe. NO footing or foundatioh drains„or other sources of ground or stornwater, shall be permitted to enter the Distdd's sanitary sewer system. The District will assume no IiabilitV for drains which are below the grade level of the 'Permit, holder (property owner„developeror builder)'.willbe responsible. For damages tothe District's sewers system including manholes, castings, manhole lids and thelike, caused, by construction activity on the building site which is the subject of this permit; the permit holder is also responsible. Inspections by thelDistdctare MANDATORY and shall bevranged by contacting'.the District's office at ti449200 one to four hours in advance. All new construction;will be_ placed on billing six months after connection,has been made: Bysigning below, I'attestdhat l am familiar with the -District's specifications and agree to accept responsibility,for:all wo one, Under ihispermit ., District'millp sump, pump 'ins ect all connections 30,to 60 days_after the lateral inspection has been om leted. (have received a copy of Ordinance No. 943-99 and"agree to follow all District standards effective with ado tion ofthis ordinance. _Conditional Pernlf Termsi " ] No CONNECTION to the sewer until further notification. i [ ] Certificate of Insurance -must be,on file with CTRWD listed as certificate holder. [ ] .48:hours notice before work'starts on, manhole,eore;drilling orcuts of `active' lines and District inspector must be on site. . [ ] AII,Districtfees will be pa d'in full. [ ]Approval pending Districts review of plans. [ ] p pp p pp priatecountyor,cityagencies ;forwork'in Copies of a roved permits a ro the right-of-wayroad cutsor are attached, [ J No occupancy until further notification .. .•' " . Y., 1. .:; I All,Conditions have.been meVand.fIM4 permit issued' 19 Builder/ er Signature Phone Printed / a InspectionFee Paid; $75.00 v v ti ntes s Permit issued this day f 2000 •� " b+ Jay W. ley, Utility Manager AtWA> Pegmit-w.12-994 Permit valid only with.CTRWD seal in red ink. I SENTRY:SCHNEIDER ENGINEERING 1-17- 0 ;10:38..AM (317)805-2803" 317 ml Itdz;S U/ J THE 30PO North Post Ruud Engineering IndlAnsp.11, Indlnnn Sur4eylTls 462M-0060 Gts • lss SCHNEIDER 317-898-8282 Geology. MASTER BVILC ER 317-895-2603 TAX . CORPORATION NOTE; 142 DRAWNG 15 UASCD ON CONSTRUCTION TLANS OR RECORD ' DRAWINGS AND IS NOT BASED UPON A FIELD SURVEY. • THE, SC11NLIDER'CORP. DOES NOT WARRANT THE ACCURACY OR SUFFICIENCY Or THIS INFORMATION. THE CONTRACTOR SHOULD VERIFY'.EXISTING CONDITIONS PRIOR TO ANY CONSIRUCTON.. ANY DISCREPANCY FOUND UPON THIS DRAWING SHOULD BE REPORTED To THE:SCHNEIDER CORP.'IMMEDIATELYi FAILURE TO DO SO WILL RESULT IN THE CONTRACTORS ASSUMPTION OF IIARILITY. I BLOCK "L" COMMON AREA LME,LSE, DE SPA SEWL'R'- — — — 8' S(DEWAI,K LOT # 185 11,080 SF le'XI2, PATIO O oa.0a I 8 20.07 F SUMP BSMT I. N 2ND MOM \ a SC EA OVHANC 200 1ASC RESJF'E.D CRAWL r---- / RSMT FFE I CAR, \ CAR = 909.8 / 30' s 15'U d'OE� OTA fl J WATER LINE _iW1\ 4L2' o 3" - K ONC N R 5 b I I APRON ELEV=907.4 PER PLAN NOTE: 111E OAGEMENT CLEVATON DOMCTE0 HEREON MAE BEEN OEItHMINEO AND BASED UPON THE PAD GRADES AND OR CONTOURS TAKEN FRO Die CONSTRUCTION PLANS FOR THE SUBDIVISION. LINLFSS STATFD, INFORMATION ABOUT FLUCTUATING WATER TABLES. SOIL CONOI (IONS f ABOVE DIE NORMAL POOL ELEVATION ER UNLESN A STUDY OF FACTS EXCAVATION PROCESS. ANY GROUNDWATER SHOULD BE HOMED IMMEDIATPMY, NAILED z' AROVF THE GROUNDWATER MONIQUCS SRIOULO 8E INCORPORATED ASSUMED NORTH SCALE 1" - 30' * APPHOXIMAIE LUCATIUN CONFIRM BEFORE OTO I CONSTRUCTION 6" SAN LATERAL & SUB —SURFACE DRAIN LATERAL lF0-0.01 PROPOSED GRADE ESPRIT DRIVE 50' R/W TC=90fi PER PLAN. Ic—_ 009.2b SEWER ., PER. PLAN PLOT PLAN PREPARED FOR: PULTE HOMES OF INDIANA PLOT PLAN LOT # 18;i SADDLE CREEK SECTION 6 INSTR. # 9909919786 PC # 2 SLIDE # 245 1557 ESPRIT DRIVE NOTE; IN THE RESIDENTIAL DISTRICTS LIMITING HEICHT TO TWENIY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEF.I75 TWENTY-FIVE (25) FEET IN HEIGHT. PER CARMEL ZONING ORDINANCE 26,1.1. SQUARE FOOTAGE; PATIO -; 216 SF PURLIC WALK -- 340 ±SF PRIVATE WALK - 80 ±Sf CONC. DRIVEWAY - 626 3SF HYDRO SEEDING - 5,985 ±SF SOD — 308 1SQ YARDS EVEN WITH FRON I OF I-ISE NOTE: GARAGE F.F.E. IS PROPOSED TO BE 2.4' ABOVE CURB AT DRIVEWAY PER PLAN. TYPICAL SWALE SECTION JOB # 00-0224-14 01/14/00 DKK