HomeMy WebLinkAbout017_S401 - GENERAL NOTES LEGEND AND ABBREV (Const Issue 7-22.PDFABBREVIATIONS LIST
AR ANCHOR RODS 0/0 OUT TO OUT
ABV ABOVE OA OVERALL
ACI AMERICAN CONCRETE INSTITUTE OC ON CENTER
ADD'L ADDITIONAL OD OUTSIDE DIAMETER
ADH ADHESIVE OF OUTSIDE FACE
ADJ ADJACENT OH OVER HEAD
AESS ARCHITECTURALLY EXPOSED OPNG OPENING
STRUCTURALSTEEL OPP OPPOSITE
AFF ABOVE FINISHED FLOOR OPP HD OPPOSITE HAND
AGGR AGGREGATE OSB ORIENTED STRAND BOARD
AHU AIR HANDLING UNIT OSL OUTSTANDING LEG
AISC AMERICAN INSTITUTE OF OVS OVERSIZE HOLE
STEEL CONSTRUCTION PAF POWDER ACTUATED FASTENER
AISI AMERICAN IRON AND PC PRECAST
STEELINSTITUTE PL PLATE
ALUM ALUMINUM PLF POUNDS PER LINEAR FOOT
ALT ALTERNATE PLYWD PLYWOOD
APPROX APPROXIMATE PNL PANEL
ARCH ARCHITECT PROJ PROJECTION
ARCH'L ARCHITECTURAL PSF POUNDS PER SQUARE FOOT
ASTM AMERICAN SOCIETY OF PSI POUNDS PER SQUARE INCH
TESTING MATERIALS PSL PARALLEL STRAND LUMBER
AWS AMERICAN WELDING SOCIETY PT PRESSURE TREATED
L ANGLE PTN PARTITION
BAL BALANCE R RADIUS
BB BOND BEAM RD ROOF DRAIN
B/B BACK TO BACK REF REFERENCE
BC BOTTOM CHORD REINF REINFORCE(D) (ING) (MENT)
BD BOARD REQ'D REQUIRED
BLDG BUILDING REV REVISION/REVISED
BLK BLOCK RO ROUGH OPENING
BLW BELOW RRD ROOF RELIEF DRAIN
BM BEAM RTN RETURN
BOTT BOTTOM RTU ROOF TOP UNIT
BP BEARING PLATE RW RETAINING WALL
BRDG BRIDGING SCHED SCHEDULE
BRG BEARING SECT SECTION
BRK BRICK SHT SHEET
BS BOTH SIDES SIM SIMILAR
BSMT BASEMENT SJ SAWCUT JOINT
BTWN BETWEEN SJI STEEL JOIST INSTITUTE
BUC BUILT UP COLUMN SL SLOPED
c CAMBER SPA SPACE(S)
C/C CENTER TO CENTER SPECS SPECIFICATIONS
CANT CANTILEVER SQ SQUARE
CAIS CAISSON SS STAINLESS STEEL
CFS COLD FORMED STEEL SSL SHORT SLOTTED HOLES
CJ CONTROL AND/OR STD STANDARD
CONSTRUCTION JOINT STIFF STIFFENERS
CL CENTERLINE STL STEEL
CLR CLEAR STRUCT STRUCTURAL
CMU CONCRETE MASONRY UNIT SYMM SYMMETRICAL
COL COLUMN T&B TOP AND BOTTOM
COORD COORDINATE T&G TONGUE AND GROOVE
COMP COMPACTED TB TIE BEAM
CONC CONCRETE TC TOPCHORD
CONN CONNECTION TEMP TEMPERATURE
CONST CONSTRUCTION TEC THEATER EQUIPMENT CONTRACTOR
CONT CONTINUOUS TF TRENCH FOOTING
CONTR CONTRACTOR THK THICK
CTR CENTER THKS THICKENED SLAB
CTR'D CENTERED THR'D THREADED
DIA DIAMETER TL TOTAL LOAD
DIAG DIAGONAL TOP'G TOPPING
DIM DIMENSION TRANS TRANSVERSE
DL DEAD LOAD TYP TYPICAL
DLT DEEP LEG TRACK UNO UNLESS NOTED OTHERWISE
DO DITTO VERT VERTICAL
DN DOWN VIF VERIFY IN FIELD
DTL DETAIL w/ WITH
DWG DRAWING WD WOOD
DWL DOWEL WO WINDOW OPENING (MASONRY)
EA EACH WP WORKING POINT
EE EACH END WT WEIGHT
EF EACH FACE WWF WELDED WIRE FABRIC
EJ EXPANSION JOINT
ENG ENGINEER ELEVATION TOP AND BOTTOM OF LIST
ELEV ELEVATION
ELECT ELECTRICAL T/ "ELEVATION, TOP OF"
EOD EDGE OF DECK B/ "ELEVATION, BOTTOM OF"
EOS EDGE OF SLAB T/BB TOP OF BOND BEAM
EQ EQUAL T/BM TOP OF BEAM
EQUIV EQUIVALENT T/CONC TOP OF CONCRETE
ES EACH SIDE T/F TOP OF FOOTING
EW EACH WAY T/LDG TOP OF LEDGE
EXIST EXISTING T/MAS TOP OF MASONRY
EXP EXPANSION T/P TOP OF PIER
EXT EXTERIOR T/SLAB TOP OF SLAB
F/ FACE OF T/STL TOP OF STEEL
FD FLOOR DRAIN T/W TOP OF WALL
FDN FOUNDATION T/GB TOP OF GRADE BEAM
FIN FINISH T/CAIS TOP OF CAISSON
FLR FLOOR B/PL BOTTOM OF PLATE
FLG FLANGE B/F BOTTOM OF FOOTING
FS FARSIDE
FTG FOOTING SPECIAL CHARACTERS
GA GAUGE
GALV GALVANIZED ° DEGREE
GB GRADE BEAM � PLUS OR MINUS
GC GENERAL CONTRACTOR ELEVATION
GL GLULAM f� DIAMETER
GR GRADE
HC HOLLOW CORE
HD HOLD DOWN
HGT HEIGHT
HI HIGH
HK HOOK
HORIZ HORIZONTAL
HP HIGH POINT
HS HEADED STUD
HSS HOLLOW STRUCTURAL SECTION
ID INSIDE DIAMETER
IF INSIDE FACE
INFO INFORMATION
INT INTERIOR
INV INVERT
JST JOIST
JT JOINT
K KIP
KO KNOCK OUT
LB POUND
LDG LEDGE
LG LONG
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LNTL LINTEL
LSL LONG SLOTTED HOLES
LONG LONGITUDINAL
LP LOW POINT
LVL LAMINATED VENEER LUMBER
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MBM METAL BUILDING MFR
MCJ MASONRY CONTROL JT
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOM MOMENT
MSW MASONRY SHEAR WALL
MSL MEAN SEA LEVEL
MTL METAL
NO NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
COL MARK, SEE SCHEDULE
P16 = PIER MARK, SEE SCHEDULE FOR ACTUAL SIZE,
T/P = TOP OF PIER ELEV � BASEPLATE AND ANCHOR
P 16 T/P -0'-8" RODS '
F4 = COL FTG MARK, SEE SCHEDULE �_ 55`� �
T/F = TOP FTG ELEV F4 T/F -2'-8" �` �
� _
�� � G
O N
, ,
� � �� �
� N
CONCRETE MASONRY UNIT WALL (MW) �� � I �
T/STL SEE SCHED FOR SIZE AND REINF I POCHE REPRESENTS
+(SEE PLAN) I � MASONRY WALL
TM/ = TOP OF WALL ELEV �
SPOT ELEV INDICATES CONCRETE WALL (CW), SEE SCHED � INDICATES EDGE
TOP OF CONC FOR WALL THICKNESS AND REINF I OF WALL FTG
INDICATES EDGE OF WALL
FTG UNDER FLOOR SLAB C 8 T/W -0'-8"
-- ---------- -� _�------
-a ' ., a - -. ' e .v - '
POCHE REPRESENTS P16 WF24 T/F_-2'-8"
� CONCRETE WALL F4
S401 CONCRETE WALL FTG (WF), SEE
SCHED FOR SIZEAND REINF
T/F = TOP OF FTG ELEV
INDICATES SECTION CUT ,� 2
2
S401
INDICATES PLAN DETAIL
COL GRID, COLUMNS CENTERED ON
GRID INTERSECTION, UNO
FOUNDATION PLAN LEGEND
SCALE: 3/4" = 1'-0"
11
COL GRID, COLUMNS
CENTERED ON GRID
INTERSECTION, UNO
BEAM CAMBER �_ _
�
M
U
�
NUMBER OF �
SHEAR STUDS �
�
INDICATES BEAM SIZE ��
INDI CATES JOIST SIZE
2
S401
INDICATES PLAN DETAIL
�
T/JOIST GIRDER ELEV � +'
Y
�
�
z
JOIST GIRDER SIZE �� �
(UNFACTORED) M
HORIZ BRIDING �
"X" BRIDGING
�o
�
r
�
Y
�
�
r
�/
�\
12
EDGE OF DECK,
� PERIMETER ANGLE
W 14x22
+23'-0„
+23'-0"
�
N
X
�
�
+24'-0"
�
�Y
.0 U
W W
� p
�
�z o
Q
Q ¢ O N
•z�z N
X
�
�
=
OPENING THRU
DECKAND FRAMING
INDICATES SECTION CUT
1
S401
TOP OF STEEL ELEV
AT GRID INTERSECTION
C
ASD REACTION IN KIPS
TOP OF STEEL ELEV
� -� INDICATES BEAM SIZE
32LH12 JOIST SIZE
I NDI CATES KNEE BRA CE
m
Y
W14x22 +24'-0" `°
D
� 2 I
MOMENT CONNECTION INDICATES BRACING
S501
INDICATES BRACING ELEVATION
FRAMING PLAN LEGEND
SCALE: 3/4" = 1'-0"
H
STRUCTURAL STEEL NOTES
SS1. All structural steel shall conform to the following:
W Shapes ASTM A992, Grade 50.
Angles, Channels, Plates, Bars ASTM A36 (Fy=36 ksi)
HSS Tubes ASTM A500, Grade B(Fy=46 ksi)
HSS Pipes ASTM A500, Grade B(Fy=42 ksi)
Anchor Rods ASTM F1554, Grade 36
SS2. All steel shall be detailed, fabricated and erected in accordance with AISC 360 "ALLOWABLE STRENGTH
DESIGN FOR STRUCTURAL STEEL BUILDINGS" and AISC 303 "CODE OF STANDARD PRACTICE", Thirteenth
Edition. Unfactored Reactions are shown on plan; Design for 6 Kips if reaction not indicated on drawings.
SS3. All bolted connections shall be made with 3/4" diameter, A325 bolts with nuts and washers, unless otherwise noted. All
connections shall be shear bearing connections tightened to snug-tight condition, unless otherwise noted. All
connections shall conform to the ASD SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490
BOLTS.
SS4. All shop and field welds shall be made using E70 electrodes or equivalent.
SS5. All headed concrete anchors shall be ASTM A108 (Fy=50 ksi), 3/4" diameter x 4" after welding, unless noted
otherwise.
SS6. Steel fabricator shall obtain the size and location of all openings for grilles, louvers, etc. before proceeding with the
fabrication and erection of any required frames.
SS7. Provide Heckman #129 and #130 channel slot and channel slot anchors at
all columns that abut masonry walls, unless noted.
SS8. Provide temporary bracing of the structure until all permanent lateral support is in place.
SS9. Structure Stability: The entire roof and/or floor decking materials must be fully erected and connected to the
supporting steel before temporary, erection bracing is removed.
SS10. RD = Roof Drain location. Provide steel frame for drains. See other drawings for actual drain type, number, size,etc.
Coordinate with drain contractor.
STEEL JOIST NOTES
SJ1. Provide all joists, bridging and accessories for the complete erection of joists in accordance with the current Steel
Joist Institute "STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB STEEL JOISTS AND JOIST
GIRDERS" and Underwriters Laboratories "STANDARD, FIRE TESTS OF BUILDING CONSTRUCTION AND
MATERIALS".
SJ2. Bridging shall be completely erected and joists aligned before any construction loads are placed on joists.
SJ3. Do not weld bottom chord of joists to columns unless noted on drawings.
SJ4. Install erection bolts at all joist girder to column and joist to column connections.
SJ5. Provide uplift bridging at all joists as per "STANDARD SPECIFICATIONS AND LOAD TABLES FOR OPEN WEB
STEEL JOISTS AND JOIST GIRDERS" for a net uplift load as shown on wind load tables.
STEEL DECK NOTES
MD1. All metal deck material, fabrication and installation shall conform to Steel Deck Institute" SDI SPECIFICATIONS
MD2. Roof deck shall be welded using a 36/7 pattern with (4) #10 TEK sidelap fastener unless otherwise shown in typical detail
MD3. Provide TS 21/2x 21/2x 1/8 deck support, field welded to joist or beam at all deck span changes.
MD4. Provide L3x3x1/4 deck support at all columns where required, unless noted.
MD5. Provide 20 gauge cover plate at all roof deck span changes.
MD6. Provide L3x3x1/4 at all unsupported edges of deck and around roof perimeter, unless otherwise noted.
MD7. All deck shall be provided in a minimum of 3-span lengths where possible.
MD8. Deck shall be fastened to prevent uplift loads shown on wind load tables.
MASONRY AND REINFORCED MASONRY NOTES
M1. Minimum 28 day compressive strength of concrete masonry units shall be 3750 p.s.i. based on net area of the unit.
Specified design compressive strength of masonry shall be fm = 2500 p.s.i. All units for exterior walls, load-
bearing walls and shear walls shall be normal weight block.
M2. All mortar shall be Type S. No admixtures may used unless approved by architect/engineer. Mortar shall not be
used for grouting cores or filling bond beams.
M3. All block shall be laid in a running bond pattern.
M4. Course grout shall be used were grouting is required. Slump shall be 8" +/-1". Minimum grout compressive
strength shall be 3000 p.s.i.
M5. All reinforcing shall be ASTM A615 Grade 60 (Fy=60 ksi). Lap all reinforcing a minimum of 48 bar diameters.
M6. See architectural and specifications for all control joint locations. Reinforcing in bond beams shall be
discontinuous at control joints.
M7. Provide ladder type horizontal joint reinforcement at 16" o.c. Side rods and cross rods shall be #9 wire, galvanized,
see specifications. Cut joint reinforcement at control joints.
M8. Provide "L" bars at all bond beam corners as required.
M9. Fill cores of block solid with grout two full courses below the bearing of all beams or lintels supported on masonry.
M10. All attachments to block shall be made with Hilti HX 1/2" diameter x 3" sleeve anchors, unless noted otherwise.
Anchors shall be installed per manufacturer's recommendations.
M11. See typical schedules for masonry and steel lintels not indicated on plans.
M12. All masonry units below grade to be grouted solid.
M13. Provide ties to all structural steel.
M14. All interior, non-load bearing masonry walls over 12'-0" high, shall be supported on thickened slab as per typical
detail. Wall vertical reinforcing shall be #5 @ 48" OC full height. Unless noted otherwise.
M15. All cores with reinforcing steel shall be grouted solid, full height of wall.
MASONRY ANCHORAGE
M1. All attachments to masonry shall be made with Hilti anchors as scheduled below unless noted otherwise. Anchors shall
be installed per manufacturer's recommendations.
M2. At steel connections to masonry construction, provide the following hole diameters in steel elements to accommodate
field tolerances:
1/2" anchors: 9/16" dia std, 13/16" dia w/ 1/4"x2"x2" weld washer where noted.
3/4" anchors:13/16" dia std,1" dia w/ 3/8"x3"x3" weld washers where noted.
M3. Where weld washers are indicated, do not weld until epoxy adhesives have fully cured. Do not apply excessive heat
which made adversely affect epoxy adhesives. Weld two opposite edges of weld washer typically with 3/16" fillet weld.
M4 Type 1-A: Grout Filled Concrete Block.
3/4"x6 5/8" embedment HIT, or A36 threaded rod, secured with Hilti HY150 epoxy.
Design values: 37401b T, 20201b V.
Type 1-B:Hollow Concrete Block (NW or LW).
1/2"x2"embedment Hilti HIT-A rod w/screen tube and Hilti HY20 epoxy.
Design values: 5251b T, 1230 Ib V.
Type 1-C:Hollow Concrete Block Through-bolt.
3/4"x8" or 13" Hilti HIT, or A36 threaded rod, w/ Hilti HY20 epoxy, screen tube, steel sleeve, 3/8"x6"x6" plate
washer.
Design values:14001b T,18001b V.
Type 1-D:Grout Filled Concrete Block.
3/4"x4-3/4" embedment Hilti Kwik Bolt II expansion bolt.
Design values: 1620 T, 3110 V(>16" from edges)
M5. Type 2-A:Hollow Brick and Clay Tile.
1/2"x3-3/8" embedment Hilti HIT-A, or A36 threaded rod, w/ Hilti HY20 epoxy and screen tube.
Design values: 7751b T, 13751b V(Brick)
1501b T, 5001b V(Clay tile)
Type 2-B:Hollow Brick and Clay Tile.
1/2"x3-3/8" embedment Hilti HIT-A, or A36 threaded rod, w/ Hilti HIT-I insert, Hilti HY20 epoxy, screen tube.
Design values: 11601b T, 16351b V(Hollow Brick)
1851b T, 5001b V(Clay Tile)
Type 2-C:Multiwythe Brick through-bolt.
3/4"x8"embedment Hilti HIT, or A36 threaded rod, w/ Hilti HY20 epoxy, screen tube, steel sleeve, 3/8"x6"x6"
plate washer.
Design values:14001b T,18001b V.
Type 2-D: Multiwythe Brick, voided wythes.
3/4"x8"embedment Hilti HIT, orA36 threaded rod, w/ Hilti HY20 epoxy, screen tube, steel sleeve.
Design values: 8001b T,14001b V.
COLD FORMED STEEL FRAMING NOTES
SF1. All light gage, cold formed steel (CFS) members shall conform to the following minimum requirements (See
drawings
for application):
TYPE SIZE OLD GAGE SPACING GRADE
Exterior Wall Studs 800 S 162-43 18 16" oc, max. ST33H (33 ksi)
Interior Studs 600 S 162-43 18 16" oc, max. ST33H (33 ksi)
SF2.
SF3.
SF3.
SF4.
SF6.
SF7.
SF8.
SF9.
All sheet steel shall comply with ASTM A1003. Coating shall be G90 galvanizing.
Provide steel tracks complying with ASTM C955, thickness to match studs, 2" flange width.
Provide 1/2" ASTM F1554, Grade 36 anchor bolts at all steel tracks, u.n.o. Anchor bolt spacing = 48" OC, u.n.o.
Provide anchor bolt at 8" from the ends of all walls, u.n.o.
All cold formed steel members shall comply with the requirements of the latest AISI Specification.
Field welding is not permitted. Provide screwed connections.
For all non-load bearing studs, provide deflection clips isolating the stud from the primary structure.
Provide 5/8" sheathing on outside face of all exterior wall studs.
GENERAL NOTES
G1. BUILDING CODES:
Model: International Building Code 2006
Local: Indiana Building Code 2007
Steel: American Institute of Steel Construction 360, ASD Thirteenth Edition
Concrete: American Concrete Institute, 318-05.
G2. DESIGN LOADS:
Roof
Dead Load: 30 psf
Live Load: 30 psf
Office Floor
Dead Load: 84 psf
Live Load: 100 psf
G3.
G4.
G5.
G6.
G7
G8.
plans,
G9.
Theater Lobby Floor:
Dead Load: 106 psf
Live Load: 100 psf
Corridor Floor:
Dead Load: 106 psf
Live Load: 100 psf
Stage Floor:
Dead Load: 94 psf
Live Load: 150 psf
SNOW
Flat Roof Snow Load: 20 psf
Snow Exposure Category: B
Snow Exposure Factor: 1
Snow Importance Factor: 1.10
Thermal Factor: 1
WIND
Basic Wind Speed: 90 mph
Wind Importance Factor: 1.15
Building Classification: Type 2
Wind Exposure Category: Enclosed
Exposure: B
SEISMIC
Seismic Use Group: Building Classification III
Seismic Importance Factor 1.25, R=5.5
Seismic Design Category: B
Spectral Response, Sds: 0.143
Spectral Response, Sd1: 0.090
Site Class: C
Basic Building System: Building Frame
Basic Resisting System: Special reinforced masonry shear walls.
Design Base Shear: 0.023W
Analysis Procedure: Equivalent lateral force.
LOADING GALLERIES - STAGEHOUSE:
Dead Load: 75 psf
Live Load: 500 psf
OPERATING GALLERIES - STAGEHOUSE:
Dead Load: 75 psf
Live Load: 150 psf
GRIDIRON - STAGEHOUSE, STAGE APRON:
Dead Load: 30 psf
Live Load (on grating) 81 psf, including concentrated loads
Live Load (on grating): 1,000 Ib conc. load over 1'-0"x1'-0" area, OR 2,000 Ib over 1'-6"x1'6"
Live Load: 300 plf (rope rigging gridwells)
MECHANICAL FLOOR:
Dead Load: 77 psf
Live Load: 150 psf
MECHANICAL MEZZANINE & CATWALKS:
Dead Load: 50 psf
Live Load: 40 psf
Reactions and forces indicated are unfactored, Allowable Strength Design loads.
If Drawings and specifications are in conflict, the most stringent restrictions and requirements shall govern.
Contractor shall bring all discrepancies to the attention of the engineer immediately.
Verify all existing conditions prior to any construction or fabrication. If different than shown, notify
engineer/architect immediately for modification of drawings.
All contractors are required to coordinate their work with all disciplines to avoid conflicts. The architectural,
mechanical, electrical and plumbing aspects are not in the scope of these drawings. Therefore, all required
materials and work may not be indicated. It is the contractor's responsibility to coordinate these drawings with all
other construction documents. Refer to architectural drawings for all dimensions not shown on these drawings.
locations, their work with all other disciplines.
The contract documents represent the structure only. They do not indicate the method of construction. The
contractor shall provide all measures necessary to protect the structure during construction. Such measures shall
include, but not limited to, bracing, shoring, underpinning, etc. McComas Engineering is not responsible for the
contractor's means, methods, techniques, sequences or safety procedures during construction.
Notes and details shall take precedence over general structural notes. Where no details or sections are shown,
construction shall conform to similar work on the project. Typical sections and details may not be cut on the
but apply unless noted otherwise.
Provisions for future expansion:
Vertical: None
Horizontal: None
REINFORCED CONCRETE NOTES (Foundations, Slabs & Walls)
RC1. All concrete shall have the following 28 day compressive strengths:
LOCATION STRENGTH AIR ENTRAINMENT
Wall Footings, Spread Footings: 3000 psi 2%
Mat Foundations 4000 psi 2%
All concrete exposed to freeze/thaw, exterior
slabs, piers, walls, columns, grade beams,
concrete exposed to freeze/thaw: 4000 psi 6%
Interior slabs on grade,
fill for metal deck: 4000 psi Non AE
RC2. All reinforcing steel shall be detailed, supplied and placed in accordance with ACI 315, ACI 318 and CRSI MSP-1.
RC3. All reinforcing steel shall be shop fabricated and, where applicable, shall be wired together and conform to ASTM A-
615, Grade 60.
RC4. Chamfer edges of exposed concrete 3/4", unless noted otherwise.
RC5. Contractor shall make four, 6"x12" test cylinders for each 50 cubic yards of concrete poured for each days operation
Break 1 at 7 days, 2 at 28 days and retain spare.
RC6. All welded wire fabric shall conform to ASTM A185, Fy(min) of 65 ksi. All welded wire fabric laps shall be 8".
RC7. All finished concrete, concrete formwork and falsework shall be in accordance with ACI 301. Contractor is solely
responsible for the design and construction of all formwork, falsework and shoring.
RC8. Provide the following coverages over reinforcing:
LOCATION
Footings: Bottom and Unformed edges 3"
Footings: Formed edges and top 2"
Slab on grade: Welded wire fabric Upper Third
Fill for Metal Deck: Welded wire fabric Upper Third
Reinforcing Steel: Bottom 2"
RC9. Provide sleeves for all openings in grade beams or walls to totally separate pipe from concrete.
SHALLOW FOUNDATION AND SLAB ON GRADE NOTES
SF1. Design Soil Bearing Pressure: @ 1st Floor @ Basement
Spread Footings 2500 psf 5000 psf
Wall Footings 2000 psf 4000 psf
(Based on soils report prepared by Patriot Engineering on July 16, 2009).
SF2. Soil to be stripped, compacted and tested in accordance with the recommendations of the soils engineer and project
specifications.
SF3. Footings shall be placed on firm, undisturbed soil or on engineered fill. Engineered Fill: Naturally or artificially graded
mixture of natural or crushed gravel, crushed stone, and natural or crushed sand; ASTM D 2940; with at least 90
percent passing a 1-1/2-inch sieve and not more than 12 percent passing a No. 200 sieve.
SF4. Slabs shall be placed on compacted, free-draining, frost-free drainage course. Drainage Course: Narrowly graded
mixture of washed crushed stone, or crushed or uncrushed gravel; ASTM D 448; COURSE-aggregate grading Size 57;
with 100 percent passing a 1-1/2-inch sieve and 0 to 5 percent passing a No. 8 sieve. All fill shall be compacted to a
minimum dry density of 95% of the modified Proctor maximum dry density (ASTM-D1557), placed in 6" to 8" lifts. Pea
gravel may not be used as fill. Utility trenches and excavations under the foundations or slabs shall meet the same
requirements. See soils investigation report for further recommendations.
SF5. Undercutting of the soil for foundation and/or slab placement may be required. These drawings do not indicate the
entire scope of undercutting, fill or bad soil removal that may be required to attain the design soil bearing pressures. It
is the responsibility of the contractor to obtain a soils investigation report, before bidding, to assess the extent of
excavation and compaction that may be required to meet the design criteria. The contractor shall retain the services of
a soils engineer to monitor all backfilling operations and to inspect footing bearing material. A report certified by the
soils engineer shall be furnished to the architectlengineer verifying that all foundations were placed on a material
capable of sustaining the design bearing pressures.
SF6. If dewatering is required, sumps shall not be placed within the foundation excavation.
SF7. Maintain a maximum slope between adjacent footing bearing elevations of 2 horizontal to 1 vertical. Maintain a 2
horizontal to 1 vertical slope next to existing foundations to avoid undermining foundations.
SF8. No horizontal joints are permitted in any foundation. Vertical joints are permitted only in wall footings.
SF9. Shallow foundations may be earth-formed where the excavation permits. If earth-forming is used, add 2" to the width
and length of all foundations.
SF10. The bottom of all foundations shall be a minimum of 36" below final grade.
SLAB ON GRADE NOTES
1. Plastic Vapor Retarder: ASTM E 1745, Class C, or polyethylene sheet, ASTM D 4397, not less than 10 mils (0.25
mm) thick. Include manufacturer's recommended adhesive or pressure-sensitive joint tape.
2. Penetrating Liquid Floor Treatment: Clear, chemically reactive, waterborne solution of inorganic silicate or
siliconate materials and proprietary components; odorless; colorless; that penetrates, hardens, and densifies
concrete surfaces. Provide Curecrete Distribution Inc.; Ashford Formula.
3. Trowel finish: Finish surfaces to the following tolerances, according to ASTM E 1155 (ASTM E 1155M), for a
randomly trafficked floor surface:
a. Specified overall values of flatness, F(F) 35; and of levelness, F(L) 25; with minimum local
values of flatness, F(F) 24; and of levelness, F(L)17.
4. No joint filling required.
Owner:
CARMEL THEATER
DEVELOPMENT COMPANY
117ll North Pennsylvania Street, Suite 200
Carmel, Indiana 46032
317.573.6050
Architect:
t��a. �.�.... �.�. � �. ��...�`
..� � i�.�.� �� ��.�..��`� `��
PEDCOR DESIGN GROUP
Architecture / Project Management
355 City Center Drive
Carmel Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
Engineer:
MCC O S
STRUCTURAL ENGINEERS FORENSIC ENGINEERS NATIONAL CONSULTANTS
1717 East 116th Street, Suite 200, Carmel, Indiana 46032
317-580-0402 www.mccomaseng.com 317-582-0766 Fax
OFFICE BLDG
�-c-2
PARKING I6,
GARAGE c�
�-c-s �
7-C-4
E.C. ----------
UNDERGROUND
- DETENTION 7-C-11�
KEY PLAN
SCALE: NTS
PLAN NORTH
Project:
COPYRIGHT & OWNERSHIP OF DOCUMENTS
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION
AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND
PEDCOR DESIGN GROUP. NO PART OR WHOLE OF THIS DESIGN, THESE
DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS
OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED,
COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR
OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR
WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND
PEDCOR DESIGN GROUP. c COPYRIGHT 2009 JAMES R. STUTZMAN, AIA,
INDIANAPOLIS.
BID PACKAGE NO. 4
Print Date: Sheet Issue Date:
07/22/10 12/22/09
Drawn By: Checked By:
LKM/njh/KLS JAF
Last Revision Date:
No. Date Description
O 02/24/10 BID PKG.2-AD.N0.1
07/22/10 CONST ISSUE SET
�
�
�
�
�
Project Number:
Parcel 7C-1
Sheet Title:
GENERAL NOTES
LEGEND AND
AB B REV
Sheet Number:
�
�
L
ME129019