Loading...
HomeMy WebLinkAbout102_M203 (Const Issue 7-22-2010).PDFO S H E ET KEYN OTES �• 48/36 RA DUCT DOWN. CAP DUCT TOP. 2. 116/60 SA FROM BELOW.. 3. 48/48 RA CONNECTED TO 68/42 RA. 4• OUTSIDE AIR INTAKE LOUVER 12'-0"W x 10'-0"H. NOMINAL MOUNTING HEIGHT 12'-0" ABOVE MECHANICAL ROOM FLOOR. 5• 12'-0"W x 7'-0"D x 7'-6"H OUTSIDE AIR INTAKE INSULATED PLENUM. 6• 18/10 RA FROM BELOW. 7• 14/14 SA DOWN. 8• 14/16 SA DOWN. 9• 24/24 SA DOWN. 10. 10'-0"W x 6'-0"H RELIEF AIR LOUVER. NOMINAL MOUNTING HEIGHT 12'-0" ABOVE MECHANICAL ROOM FLOOR. � 1• 5'-0"W x 6'-0"H RELIEF AIR LOUVER. NOMINAL MOUNTING HEIGHT 12'-0" ABOVE MECHANICAL ROOM FLOOR. PROVIDE 3'-0" DEEP INSULATED PLENUM. 12• INSTALL RLF-2 1'-8" ABOVE MECHANICAL PLATFORM. PROVIDE ADDITIONAL BRACING FOR WALL HOUSING. 13• PROVIDE 12"x12" ACCESS PANEL. 14. FOR DUCT OPENING COVER REFER TO DETAIL 9/M501. 15. EXTEND TRANSFER/RETURN AIR AIR DUCTWORK ABOVE DOOR (TYP.). 16. 18/24 ELEVATOR VENT WITH GOOSENECK. INTERLOCK NORMALLY OPEN, HOLD—CLOSED MOTORIZED DAMPER WITH SMOKE DETECTION SYSTEM. INSTALL MOTORIZED DAMPER WITHIN DUCT AT ROOF LEVEL. MECHANICAL CONTRACTOR TO PROVIDE 24V TRANSFORMER. 17. 60x120 TYPE ACDSH ACOUSTICAL ROOF FIRE VENT. REFER TO ARCH. DWG. 18• INSTALL 48/36 AS HIGH AS POSSIBLE ABOVE CEILING. FOR DUCT OPENING COVER REFER TO DETAIL 9/M501. 19• COVER DUCT OPENING PER DETAIL 9/M501. HVAC TH I RD FLODR - CATWALK OBSERVATION GALLERY PLAN SCALE: 1/8" = 1'-0" 0 4' 8' 16' Owner: CARMEL THEATER DEVELOPMENT COMPANY 11711 North Pennsylvania Street, Suite 200 Carmel, Indiana 46032 317.573-6050 Architect: . . � : � �, 4 ,' PEDCOR DESIGN GROUP Architecture / Project Management: 355 City Center Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Engineer: L'AC UIS CONSULTING ENGINEERS 9229 DELEGATES ROW, SUTTE 550 INDIANAPOLIS, IN 46240 317.706.2075 WWW.LACQUIS.COM 7-C-4 E.C. OFFICE BLDG.7-C-2 PARKING GARAGE 7-C-3 — — — — 7-C-11 KEY PLAN �� �� Project: r 1 U � ti J M W � U Z � � �� Q c� � N � � � M � C� � O z � � � � � � W c� .. W � — Z ._ � m � — o � � �� J � U W w '— � � _ � � ._ � pC � � � Q m o z � U O � U � w `� a� C� � Q � J J � COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL, ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATIDN IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS, ALL INFORMATIDN CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R, STUTZMAN, AND PEDCOR DESIGN GRDUP, LLC, NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED,PHOTOGRAPHED,PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTEDIN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R, STUTZMAN AND PEDCOR DESIGN GROUP, LLC, c COPYRIGHT 2006, 2007, 2008, 2009 JAMES R, STUTZMAN, AIA, INDIANAPOLIS, BID PACKAGE N0. 3 CONSTRUCTION ISSUE SET rin a e Sheet Issue Date 07/22/10 04/01 /10 Drawn By Checked By OSO AJM Last Revision Date: O O O O O O Project Number: Parcel 7C-1 Sheet Title: HVAC THIRD FLOOR CATWALK/OBSERV. GALLERY Sheet Number: