HomeMy WebLinkAbout135_E001 (Const Issue 7-22-2010).PDFFI RE ALARM I DENTITY SYMBOLS � CONTROL RELAY � CONTROL RELAY ❑F Q HORN AND STROBE � HORN UNIT ONLY � STROBE UNIT ONLY F s SPEAKER AND STROBE ❑F MANUAL PULL STATION sO SMOKE DETECTOR � DUCT SMOKE DETECTOR WITH TWO AUXILIARY CONTACTS RTs REMOTE STATION FOR DUCT DETECTOR USED AT DUCT WORK OPENING DA AREA TYPE SMOKE DETECTOR USED AT DUCT WORK OPENING � ELEVATOR RECALL WITH AUXILIARY CONTACTS Q,� SELF CONTAINED SMOKE DETECTOR-SINGLE STATION TYPE Q, SMOKE DETECTOR-VISUAL AND AUDIBLE SIGNAL � BEAM SMOKE DETECTOR, "R"-INDICATES RECEIVER Q5 BEAM SMOKE DETECTOR, "S" INDICATES SENDING UNIT � CARBON MONOXIDE DETECTOR. LINE VOLTAGE WITH BATTERY BACKUP � FLAME DEfECTOR � AUTOMATIC HEAT DETECTOR, "R" INDICATES RATE OF RISE � AUTOMATIC HEAT DETECTOR, "F" INDICATES FIXED TEMPERATURE 190'F � HYDROGEN DETECTOR � MOTOR OPERATED FIRE/SMOKE DUCT DAMPER Fs WATER FLOW SWITCH, BY DIVISION 15 � LOW PRESSURE SWITCH, BY DIVISION 15 ❑Ts TAMPER SWITCH, BY DIVISION 15 P�v POST INDICATOR VALVE, BY DIVISION 15 Eo� END-OF-LINE RESISTOR FIRE ALARM COMM I DENTITY SYM BOLS � FIRE ALARM MASTER BOX � FIRE FIGHTER'S PHONE FT CODE TRANSMITTER � DRILL KEY SWITCH � KEY REPOSITORY (KNOX BOX) FA FIRE ALARM ANNUNCIATOR PANEL, 2 LINES OF 4' CHARACTERS LCD DISPLAY FACP FIRE ALARM CONTROL PANEL EVA VOICE EVACUATION PANEL FATC FIRE ALARM TERMINAL CABINET BAn BATTERY PACK AND CHARGER As� AIR SAMPLING CONTROL/DETECTOR PANEL WITH ASSOCIATED AIR SAMPLING PIPING NETWORK �R TRANSPONDER IAM INDIVIDUALLY ADDRESSABLE MODULE- MONITOR (PROVIDES ADDRESS FOR CONTACT) � INDIVIDUALLY ADDRESSABLE MODULE- RELAY (PROVIDES CONTACT CLOSURE) ONE-LINE IDENTITY SYMBOLS CAPACITOR � CIRCUIT BREAKER (OPEN), "xxAF" INDICATES FRAME SIZE, yyAT "yyAT" INDICATES TRIP SIZE ,oc� CIRCUIT BREAKER (ENCLOSED), "xxAF" INDICATES FRAME »'�`T SIZE, "yyAT" INDICATES TRIP SIZE � PRIMARY DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" yyAT INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE ,ou� LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER, "xxAF" �T INDICATES FRAM SIZE, "yyAT" INDICATES TRIP SIZE ,� LOW VOLTAGE DRAW OUT TYPE CIRCUIT BREAKER. WITH yyAT CURRENT LIMITING FUSES, "xxAF" INDICATES FRAME SIZE, �► "yyAT" INDICATES TRIP SIZE, "zzA" INDICATES FUSE RATING CONTACT NORMALLY OPEN (NO) ("TC"-WITH TIMED CLOSING) CONTACT NORMALLY CLOSED (NC) ("TO"-WITH TIMED OPENING) 0 CURRENT TRANSFORMER CABINET 1�► FUSED CUTOUTS, "zzA" INDICATES FUSE RATING � 1 DISCONNECT SWITCH UNFUSED � 1 »„ DISCONNECT SWITCH AIR BREAK WITH FUSE, zzA � INDICATES FUSED RATING �► FUSE, "zzA" INDICATES FUSED RATING �r OVERLOAD RELAY � GROUNDING CONNECTION-SYSTEM AND OR EQUIPMENT K2 KIRK KEY INTERLOCK SYSTEM LIGHTNING ARRESTER AND GROUNDING TO PROTECT ALL �o--�r PHASES 3 MOTOR AND LABEL, "3" DENOTES HORSEPOWER �a-�oc-x-x Mo MOTOR OPERATOR FOR CIRCUIT BREAKERS OR SWITCH �� NETWORK PROTECTOR � PANEL BOARD � POTHEAD � STRESS CONE �'�✓�/� RESISTOR O SHUNT TRIP l� � MAGNEfIC STARTER WITH NEMA SIZE INDICATED c�i GROUND FAULT CIRCUIT INTERRUPTER, PERSONNEL PROTECTION � XXX � � XXXv Xo GENERATOR GENERATOR n �:,.� T� TRANSFORMER, DRY TYPE, UNLESS OTHERWISE INDICATED � rr/�v r r� aee � POTENTIAL TRANSFORMER, "3" INDICATES QUANTITY (3) �3� CURRENT TRANSFORMER, "3" INDICATES QUANTITY, ��,� "400-5A" INDICATED RATIO Q 3-PHASE, 3-WIRE DELTA CONNECTION � CORNER GROUNDED DELTA � 3-PHASE, 4-WIRE WYE CONNECTION (GROUNDED N EUTRAL) ,� ADJUSTABLE FREQUENCY DRIVE 3 REFERENCES DETAIL xx-x-x N U M BER �' �' � BUS DUCT OR BUS WAY �' �" ""� �"Y WIRE WAY �"�`�" TRANSFER SWITCH SWITCH BOARD M ETER I DENTITY SYM BOLS CM CUSTOMER MEfER OD DEMAND METER (UTILITY) WM WATTHOUR METER (UTILITY) SECURITY IDENTITY SYMBOLS � CCN CAMERA "WP" INDICATES WEATHER-PROOF EXTERIOR CAMERA � CCN COAXIAL CABLE OUTLET AND POWER OUTLET � CCN MONITOR OUTLET C�a DOORBELL a0/ DOOR BUZZER B� DOOR CHIME � ELECTRIC DOOR OPENER Es ELECTRIC DOOR STRIKE ic INTERCOM UNIT - FLUSH MOUNT M� MASTER INTERCOM AND DIRECTORY UNIT � MOTION DEfECTOR � SECURITY DOOR ALARM MAGNETIC LOCK � SECURITY CARD READER. "WP" INDICATES WEATHER-PROOF sc SECURITY CONTROL PANEL � SECURITY DOOR CONTACTS O SECURITY EXIT PUSH BUTTON ❑K SECURITY KEYPAD SWITCH I DENTITY SYMBOLS S SINGLE POLE SWITCH S� SWITCH (EDIT AS NEEDED FOR 2-WAY, 3-WAY, a SWITCH • LEG ETC. S� SWITCH (EDIT AS NEEDED FOR 2-WAY, 3-WAY, OR a ' SWITCH LEG ETC. S� CIRCUIT BREAKER SWITCH SpT SINGLE POLE/DOUBLE THROW SWITCH S� GLOW SWITCH TOGGLE, GLOWS IN OFF POSITION SH HORIZONTALLY MOUNTED-WITH ON POSITION TO THE LEFT SK KEY OPERATED SWITCH KEY OPERATED SWITCH WITH PILOT LIGHT ON WHEN SKP SWITCH IS ON S�� LOW VOLTAGE SWITCH S� LOW VOLTAGE MASTER SWITCH SM� MOMENTARY CONTACT SWITCH SP SWITCH WITH PILOT LIGHT ON WHEN SWITCH IS ON ST TIMER SWITCH S� WEATHERPROOF SINGLE POLE SWITCH � DIMMER SWITCH. RATED 1000W, UNLESS OTHERWISE INDICATED. "LV" = LOW VOLTAGE "FL" = FLUORESCENT 4 OCCUPANCY SENSOR, WALL MOUNTED WITH OFF-AUTO OVERRIDE SWITCH OCCUPANCY SENSOR, CEILING MOUNTED, "P"- INDICATES O MULTIPLE SWITCHES WIRED IN PARALLEL COMMUNICATION I DENTITY SYM BOLS 0 DATA OUTLET � DATA OUTLEf FLOOR TYPE � TELEPHONE/DATA OUTLET � TELEPHONE/DATA OUTLEf FLOOR TYPE � TELEPHONE OUTLET �w TELEPHONE OUTLET-WALL MOUNTED � TELEPHONE OUTLEf FLOOR TYPE � CALL IN SWITCH � CABLE ANTENNA SYSTEM OUTLET (CAN) �M MASTER ANTENNA SYSTEM OUTLEf (MAN) � MICROPHONE OUTLEf-FLOOR MOUNTED � MICROPHONE OUTLET-WALL MOUNTED MONITOR/PAGE SPEAKER-CEILING MOUNTED. SUBSCRIPT � REPRESENTS ZONE NUMBER. R= RECESSED, S= SURFACE MTD. � SPEAKER-WALL MOUNTED � SPEAKER HORN �I SPEAKER BI-DIRECTIONAL PAGING-WALL MOUNTED OI SPEAKER BI-DIRECTIONAL PAGING-CEILING MOUNTED ic INTERCOM UNIT-FLUSH MOUNTED M� MASTER INTERCOM AND DIRECTORY UNIT � VOLUME CONTROL � EQUIPMENT CABINET � EQUIPMENT RACK-WALL MOUNTED � EQUIPMENT RACK-FREE STANDING �� TERMINAL CABINEf WITH 3/4" PLYWOOD BACKING � PLYWOOD BACKBOARD DISTRIBUTION IDENTITY SYMBOLS � LIGHTING OR POWER PANEL, RECESSED � LIGHTING OR POWER PANEL, SURFACE � DISTRIBUTION PANEL � LIGHTING OR POWER PANEL ON NORMAL/GENERATOR FEEDER � DISTRIBUTION PANEL ON NORMAL/GENERATOR FEEDER � MOTOR CONTROL CENTER (MCC) � DRY TYPE TRANSFORMER . TRANSFORMER-PAD MOUNT cT CURRENT TRANSFORMER CABINET c� GENERATOR OO METER � METER AND SOCKET � TRANSFER SWITCH LIGHTING IDENTITY SYMBOLS � SURFACE MOUNTED 2'x4' FIXTURE � SURFACE MOUNTED 2'x4' EMERGENCY FIXTURE � RECESSED MOUNTED 2'x4' FIXTURE � RECESSED MOUNTED 2'x4' EMERGENCY FIXTURE 0 SURFACE MOUNTED 1'x4' FIXTURE � SURFACE MOUNTED 1'x4' EMERGENCY FIXTURE � RECESSED MOUNTED 1'x4' FIXTURE � RECESSED MOUNTED 1'x4' EMERGENCY FIXTURE O SURFACE MOUNTED FIXTURE 0 SURFACE MOUNTED EMERGENCY FIXTURE � RECESSED MOUNTED FIXTURE � RECESSED MOUNTED EMERGENCY FIXTURE O POLE MOUNTED FIXTURE 0 POLE MOUNTED EMERGENCY FIXTURE 0 SUSPENDED FIXTURE � SUSPENDED EMERGENCY FIXTURE i-O WALL MOUNTED FIXTURE � WALL MOUNTED EMERGENCY FIXTURE -r�- WALL MOUNTED FIXTURE � WALL MOUNTED EMERGENCY FIXTURE I—I LUMINAIRE STRIP TYPE FIXTURE (2 FOOT) �� LUMINAIRE STRIP TYPE FIXTURE (3 FOOT) �� LUMINAIRE STRIP TYPE FIXTURE (4 FOOT) � � EXIT LIGHTING FIXTURE, ARROWS AND EXIT FACE AS � INDICATED ON DWGS (MOUNTING HEIGHTS TO BE DETERMINED BY JOB SPECIFICATION � � "d FIXTURE-DOUBLE OR SINGLE HEAD SPOT LIGHT �4 � EMERGENCY BATTERY UNIT WITH LIGHTING HEADS �► EMERGENCY BATTERY REMOTE LIGHTING HEADS � LIGHT TRACK, LENGTH AS INDICATED ON DWGS WITH NUMBER OF LIGHTS INDICATED ON DWGS AND SCHEDULE � IN-GROUND OR FLOOR MOUNTED FIXTURE �-O SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE o-❑ SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE o-0 SINGLE LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE �o TWIN LUMINAIRE POLE MOUNTED SITE LIGHTING FIXTURE o-� ROADWAY LUMINAIRE-COBRA HEAD � BOLLARD TYPE SITE LIGHTING FIXTURE ABBREVIATIONS AN D TERMS � PHASE EWC ELECTRIC WATER COOLER OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED 'F DEGREES FAHRENHEIT EX EXISTING OL OVERLOAD A/C AIR CONDITIONING FCU FAN COIL UNIT OZ OUNCE A AMPERES FLR FLOOR P POLE ACCU AIR COOLED CONDENSING UNIT FPVAV FAN POWERED VAV UNIT PE PNEUMATIC ELECTRIC AF AMPERE FUSE FT FOOT, FEET PH PHASE AFC ABOVE FINISHED COUNTER FURN FURNACE PSI POUNDS PER SQUARE INCH AFF ABOVE FINISHED FLOOR G GROUND PSIA POUNDS PER SQUARE INCH ABSOLUTE AHU AIR HANDLING UNIT GC GENERAL CONTRACTOR PSIG POUNDS PER SQUARE INCH GAUGE AIC AMPERES INTERRUPTING CAPACITY GFI GROUND FAULT INTERRUPTING PTAC PACKAGED TERMINAL AIR CONDITIONER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE HHWP HEATING HOT WATER PUMP RCPT RECEPTACLE ARCH ARCHITECT HO HUB OUTLET REV REVOLUTIONS AVG AVERAGE HOA HAND-OFF-AUTOMATIC RM ROOM B/I BYPASS ISOLATION HORIZ HORIZONTAL RPM REVOLUTIONS PER MINUTE BE BOTTOM ELEVATION HP HORSEPOWER RPS REVOLUTIONS PER SECOND BHP BRAKE HORSEPOWER HR HOUR(S) RTU ROOF TOP UNIT BLDG BUILDING HRTU HEATING ONLY ROOFTOP UNIT SF SQUARE FOOT BSMT BASEMENT Hz HERTZ SPEC SPECIFICATION BtuH BRITISH THERMAL UNIT PER HOUR ID INSIDE DIAMEfER SQ SQUARE C CONDUIT IN INCH, INCHES ST SHUNT TRIP CB CIRCUIT BREAKER INT INTERIOR STD STANDARD CCW COUNTERCLOCKWISE INV INVERT SW SWITCH CH CHILLER K KELVIN TBI TO BE INSTALLED CHWP CHILLED WATER PUMP kW KILOWATT TBR TO BE REMOVED CLG CEILING LBS POUNDS TR TO REMAIN COMPR COMPRESSOR LTG LIGHTING TE TOP ELEVATION COND CONDENSER MAX MAXIMUM TEMP TEMPERATURE CONV CONVECTOR MBH THOUSAND Btu PER HOUR TF TRANSFER FAN CT COOLING TOWER MC MECHANICAL CONTRACTOR TRANS TRANSITION CU CONDENSING UNIT MCA MINIMUM CIRCUIT AMPS TYP TYPICAL CUH CABINEf UNIT HEATER MCC MOTOR CONTROL CENTER UH UNIT HEATER CUV CLASSROOM UNIT VENTILATOR MFR MANUFACTURER UON UNLESS OTHERWISE NOTED CW CLOCKWISE MIN MINIMUM UV UNIT VENTILATOR CWP CONDENSER WATER PUMP MISC MISCELLANEOUS V VOLTS DC DIRECT CURRENT MTD MOUNTED VAV VARIABLE AIR VOLUME DED DEDICATED CIRCUIT MV MEDIUM VOLTAGE VB VACUUM BREAKER DS DISCONNECT SWITCH NA NOT APPLICABLE VERT VERTICAL DWG DRAWING NEC NATIONAL ELECTRIC CODE VF VENTILATION FAN EA EACH NIC NOT IN CONTRACT VFD VARIABLE FREQUENCY DRIVE EC ELECTRICAL CONTRACTOR NL NON-LINEAR W WIRE, WATT EF EXHAUST FAN NOM NOMINAL WP WEATHERPROOF EFF EFFICIENCY NTS NOT TO SCALE W/ WITH EL ELEVATION OD OUTSIDE DIAMETER, OVERFLOW DRAIN W/0 WITHOUT ETR EXISTING TO REMAIN POWER I DENTITY SYM BO LS � SINGLE CONVENIENCE RECEPTACLE � DUPLEX CONVENIENCE RECEPTACLE. 20A 125V. WALL MOUNT DEVICE � DOUBLE DUPLEX CONVENIENCE RECEPTACLE. � SINGLE CONVENIENCE RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT � DUPLEX CONVENIENCE RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT � DOUBLE DUPLEX CONVENIENCE RECEPTACLE ON EMERGENCY/STANDBY CIRCUIT � SPECIAL RECEPTACLE a CLOCK HANGER OUTLET RECESSED MOUNTED 8'-0" AFF � OR 8" BELOW CEILING AS INDICATED � MULTI-OUTLET ASSEMBLY � MULTI-OUTLET ASSEMBLY � FLOOR DUPLEX CONVENIENCE RECEPTACLE. � FLUSH MOUNT FLOOR BOX, ADJUSTABLE, WITH BOTH POWER AND VOICE/DATA RECEPTACLES Q JUNCTION BOX � MOTOR � PUSH-BUTTON � ON/OFF PUSH-BUTTON STATION . aTHREE FUNCTION PUSH-BUTTON SWITCH � (UP/DOWN/STOP) $,� MOTOR STARTER SWITCH � TOGGLE DISCONNECT SWITCH � THERMAL MOTOR SWITCH WITH HANDLE GUARD AND PADLOCK CAPABILITY, "P"-INDICATES PILOT LIGHT �P � DISCONNECT SWITCH, UNFUSED TYPE � DISCONNECT SWITCH, FUSED TYPE � ENCLOSED CIRCUIT BREAKER ❑� MAGNETIC CONTACTOR � MAGNETIC MOTOR STARTER � COMBINATION MAGNETIC STARTER AND DISCONNECT SWITCH .- PHASE, NEUTRAL, GROUND ; PHASE, PHASE, NEUTRAL, GROUND = PHASE, PHASE, PHASE, NEUTRAL, GROUND . - PHASE, PHASE, NEUTRAL, NEUTRAL, GROUND . : PHASE, PHASE, GROUND = PHASE, PHASE, PHASE, GROUND .- � HOMERUN PHASE, NEUTRAL, GROUND, HOMERUN • GROUND ♦ CONNECTION GENERAL ELECTRICAL NOTES A. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE APPROXIMATE. ALL LOCATIONS SHALL BE FIELD VERIFIED. B. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE - LATEST EDITION ADOPTED BY INDIANA, THE INDIANA ELECTRICAL CODE AMENDMENTS, LOCAL/MUNICIPAL CODES, AND THE AUTHORITY HAVING JURISDICTION. C. ALL CONNECTIONS TO EQUIPMENT SUBJECT TO MOVEMENT OR VIBRATION SHALL BE LIQUID TIGHT FLEXIBLE METAL CONDUIT, NOT LESS THAN 12" IN LENGTH, NOR GREATER THAN 36" IN LENGTH. D. ALL CONDUIT PENEfRATIONS SHALL BE SEALED WITH APPROPRIATE CONDUIT SEALING MATERIAL. E. ALL CABLE SIZES SHALL UTILIZE COPPER CONDUCTORS. FIELD VERIFY LOCATIONS OF BUILDING EXPANSION JOINTS WHEN ROUTING CONDUIT. ALL CONDUITS CROSSING EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION FITTINGS. EXPANSION FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC, AND MANUFACTURER'S WRITTEN RECOMMENDATIONS. FEEDERS FROM PANEL BOARDS BACK TO MAIN SWITCHBOARD, BETWEEN AUTO TRANSFER SWITCHES AND THEIR SOURCES/LOADS, BETWEEN DRY-TRANSFORMERS AND THEIR SOURCES/LOADS. ARE NOT INDICATED ON THE FLOOR PLAN DRAWINGS. FEEDERS ARE PART OF THE WORK, AND SHALL BE SIZED AS INDICATED ON THE ONE LINE DIAGRAM. CABLE TRAY IS SHOWN ON THE PLANS. IF PORTIONS OF CABLE TRAY CANNOT BE INSTALLED DUE TO CONFLICT WITH STRUCTURE OR OTHER EQUIPMENT, THE CONTRACTOR SHALL PROVIDE (2) 4" C. WITH INSULATED BUSHINGS THAT OVERLAP 1" INTO THE TRAY TO AVOID CONFLICTS IN THESE LOCATIONS. HOME RUNS SHALL NOT BE COMBINED IN A RACEWAY UNLESS SHOWN ON THE CONTRACT DRAWINGS. SINGLE PHASE BRANCH CIRCUIT HOME RUNS MAY BE COMBINED AT THE CONTRACTOR'S DISCRETION NOT GREATER THAN (3) PHASE CONDUCTORS, (3) NEUTRAL CONDUCTORS, AND A GROUNDING CONDUCTOR. EACH SINGLE PHASE BRANCH CONDUCTOR SHALL HAVE A DEDICATED NEUTRAL BACK TO THE PANEL. CONDUITS 2" AND LARGER THAT PENETRATE EXTERIOR WALLS SHALL USE LINK-SEALS. WHERE LOW VOLTAGE (CONTROL) CABLING IS ALLOWED TO BE INSTALLED WITHOUT A RACEWAY, IT SHALL BE SUPPORTED PER SECTION 260523 NOT EXCEEDING INTERVALS OF 48 INCHES, AND NOT MORE THAN 6 INCHES FROM CABINETS, BOXES, FITTINGS, OUTLETS, RACKS, FRAMES AND TERMINALS. NOTATION DE IGNATOR GENERAL NOTES: NOTES THAT APPLY EQUALLY TO ALL DISCIPLINES WITHIN THE DRAWING SET. GENERAL ELECTRICAL NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN NOTES: THE DISCIPLINE. GENERAL SHEET NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON NOTES: WHICH THEY APPEAR. SHEET KEYNOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON WHICH THEY APPEAR AND USE A KEYNOTE INDICATOR TO IDENTIFY ITEMS. SUBSET DESIGNATORS G-000 GENERAL A-000 ARCHITECTURAL F-000 FIRE PROTECTION P-000 PLUMBING M-000 MECHANICAL E-000 ELECTRICAL T-000 TELECOMMUNICATION SHEETTYPE DESIGNATORS E-000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES) E-100 PLANS (DEMOLITION, SITE, FOUNDATION) E-200 PLANS (POWER) E-300 PLANS (LIGHTING) E-400 LARGE SCALE VIEWS (PLANS, SECTIONS) E-500 DETAILS E-600 SCHEDULES E-700 SHORT SPECIFICATIONS E-800 DIAGRAMS (CONTROLS, RISERS, ONE-LINES) E-900 3D REPRESENTATIONS (ISOMETRICS) REFERENCE SYM BOLS SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA FOR KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR ADDITIONAL ADDITIONAL INFORMATION. INFORMATION. SECTION LOCATION BEYOND AREA KEYNOTE INDICATORS IN DRAWING MODULE EXTENSION NUMERICAL CHARACTER PLAN RELATES TO ITEM A1 POINT LEADER 1 1 1 E-301 AREA LEADER SECTION LOCATION AT SUBSET SHEET LINE LEADER DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL DRAWING BLOCK REFERENCE DRAWING MODULE LOCATION FOR INFORMATION. TITLE INDICATOR: ADDITIONAL INFORMATION. LARGE SCALE VIEW LOCATION DETAIL LOCATION IN DRAWING MODULE LOCATION IN DRAWING MODULE DRAWING MODULE (IDENTIFYING LOWER LEFT OF MULTIPLE MODULES) � � ^ � aL A1 A1 � DRAWING BLOCK TITLE E-401 I E-501 � �� SCALE: �/s" _ �'-o" 0 4' s' �s' �_I `� NUMERIC SCALE GRAPHIC SCALE NORTH ARROW LARGE SCALE VIEW LOCATION DEfAIL LOCATION AT AT SUBSET SHEEf SUBSEf SHEEf MATCH LINE REFERENCE SHEEf LOCATION FOR ADDITIONAL REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL INDICATOR: INFORMATION. INFORMATION. FLOOR PLAN OVERLAP B�OND AREA REVISION INDICATOR � EXTENSION n SEE E-102 � � �� � REFER TO ADDITIONAL PLAN SHEEf FOR CONTINUATION REVISION CLOUD LIGHTING INDICATOR: REFERENCE SCHEDULE LOCATION FOR ADDITIONAL INFORMATION. A "A" = FIXTURE TYPE, REFER TO FIXTURE SCHEDULE, a� "2" = CIRCUIT NUMBER, "a" = SWITCH IDENTIFICATION J � • J ■1 � ■1 J J Owner: CARMEL THEATER DEVELOPMENT COMPANY 117ll North Pennsylvania Street, Suite 200 Carmel, Indiana 46032 317.573-6050 Architect: . � rt �, PEDCOR DESIGN GROUP Architecture / Project Management: 355 City Center Drive Carmel, Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Engineer: L'AC UI S CONSULTING ENGINEERS 9229 DELEGATES ROW, SUITE 550 INDIANAPOLIS, IN 46240 317.706.2075 WWW.LACQUIS.COM �� -°{�r���+ ' � �. 7-C-4 E.C. OFFICE BLDG.7-C-2 PARKING 7- -9 GARAGE 7-C-3 — — — — 7-C-11 KEY PLAN sc��� �s PLAN N�RTH Project: COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL, ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATIDN IN DEROGATION OF COMMON LAW COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS, ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R, STUTZMAN, AND PEDCOR DESIGN GRDUP, LLC, NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED,PHOTOGRAPHED,PUBLISHED,MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R, STUTZMAN AND PEDCOR DESIGN GROUP, LLC, c COPYRIGHT 2006, 2007, 2008, 2009 JAMES R, STUTZMAN, AIA, INDIANAPOLIS, BID PACKAGE N0. 3 CONSTRUCTION ISSUE SET Print Date Sheet Issue Date 07/22/10 04/01 /10 Drawn By Checked By MAR PCB Last Revision Date: O O O O O O Project Number: Parcel 7C-1 Sheet Title: ELECTRICAL SYMBOLS AND ABBREVIATIONS SHEET Sheet Number: