HomeMy WebLinkAbout146_E302-0002 (Const Issue 7-22-2010).PDFGENERAL NOTES
A. DIVISION 26 CONTRACTOR IS REQUIRED TO REVIEW, COMMENT AND COORDINATE ALL
WORK PRIOR TO ROUGH—IN WITH PLANS PREPARED BY ARTEC, ARCHITECTURAL
PLANS/SECTIONS/DETAILS. FAILURE TO FULLY COORDINATE MAY RESULT IN REWORK AT
DIVISION 26 CONTRACTOR'S EXPENSE.
O SH EET KEYNOTES
1. PROVIDE LIGHTING FIXTURE WITH AUTOMATIC EMERGENCY GENERATOR TRANSFER DEVICE
(GTD). SEE DETAIL ON SHEET E-501.
2. LUTRON N1500 WALL DIMMERS.
3. SEE THIRD FLOOR LIGHTING PLAN FOR ADDITIONAL OVERHEAD LIGHTING IN THIS ROOM.
4. PROVIDE LIGHTING FIXTURES BENEATH THE MECHANICAL CATWALK.
5. LIGHT SWITCHES CONTROL ALL LIGHTING FIXTURES IN THIS ROOM. SEE ELECTRICAL
THIRD FLOOR LIGHTING PLAN FOR ADDITIONAL OVERHEAD LIGHTING FIXTURES.
6. CONNECT LIGHTING FIXTURES IN THIS ROOM TO RELAY PANEL IN DIMMER ROOM 310,
UNLESS OTHERWISE NOTED.
7• 1 2"C, 28—#10 AND 1—#10 GRD TO STAGE DIMMER BOARD IN DIMMER ROOM 310.
EQUIPMENT/DEVICE PROVIDED BY THEATRICAL EQUIPMENT CONTRACTOR (TEC) AND THE
APPROPRIATE JUNCTION BOXES, CONDUIT AND WIRE ROUTED FROM EQUIIPMENT/DEVICES
TO THE STAGE DIMMER BOARD (SDB) AND ALL FINAL CONNECTIONS PROVIDED BY
DIVISION 26. COORDINATE AND VERIFY THE EXACT LOCATIONS AND ELECTRICAL
REQUIREMENT WITH THEATRICAL EQUIPMENT CONTRACTOR (TEC).
8. CONNECT LIGHTING FIXTURES IN THIS ROOM TO LOW VOLTAGE LIGHT SWITCHES LOCATED
BELOW AND TO RELAY PANEL IN DIMMER ROOM 310 UNLESS OTHER WISE NOTED. SEE
SHEET E301 FOR LOCATION OF LIGHT SWITCHES BELOW.
9• 1 1/2"C, FOURTEEN (14) CATEGORY 6 CABLES AND 1—#12 GRD TO ETHERNET
PROCESSOR IN STAGE DIMMER BOARD (SDB) FOR LIGHTING CONTROL.
10. 1 3/4"C, 2—#10 AND 1—#10 GRD TO STAGE DIMMER BOARD IN DIMMER ROOM 310.
EQUIPMENT/DEVICE PROVIDED BY THEATRICAL EQUIPMENT CONTRACTOR (TEC) AND THE
APPROPRIATE JUNCTION BOXES, CONDUIT AND WIRE ROUTED FROM EQUIIPMENT/DEVICES
TO THE STAGE DIMMER BOARD (SDB) AND ALL FINAL CONNECTIONS PROVIDED BY
DIVISION 26. COORDINATE AND VERIFY THE EXACT LOCATIONS AND ELECTRICAL
REQUIREMENT WITH THEATRICAL EQUIPMENT CONTRACTOR (TEC).
� 1• (1) 1"C, ONE (1) CATEGORY 6 CABLE AND 1—#12 GRD TO ETHERNET PROCESSOR IN
STAGE DIMMER BOARD (SDB) FOR LIGHTING CONTROL.
ROOM LEG EN D
Owner:
CARMEL THEATER
DEVELOPMENT COMPANY
117ll North Pennsylvania Street, Suite 200
Carmel, Indiana 46032
317.573-6050
Architect:
PEDCOR DESIGN GROUP
Architecture / Project Management:
355 City Center Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
Engineer:
L'AC UI S
CONSULTING ENGINEERS
9229 DELEGATES ROW, SUITE 550
INDIANAPOLIS, IN 46240
317.706.2075
WWW.LACQUIS.COM
�� -°{�r��a+ ' '
� �.
7-C-4
E.C.
OFFICE
BLDG.7-C-2
PARKING 7- -9
GARAGE
7-C-3
— — — —
7-C-11
KEY PLAN
��
��
Project:
COPYRIGHT & OWNERSHIP OF DOCUMENTS
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE
SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP.
ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL, ITS
SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE
CONSTRUED AS PUBLICATIDN IN DEROGATION OF COMMON LAW
COPYRIGHT,INTELLECTUAL PROPERTY RIGHTS OR OTHER
RESERVED RIGHTS, ALL INFORMATION CONTAINED HEREIN
CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE
ARCHITECT, JAMES R, STUTZMAN, AND PEDCOR DESIGN GRDUP, LLC,
NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE
RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE
RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED,
EXHIBITED,PHOTOGRAPHED,PUBLISHED,MODIFIED OR OTHERWISE
DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR
WRITTEN CONSENT OF THE ARCHITECT, JAMES R, STUTZMAN AND
PEDCOR DESIGN GROUP, LLC, c COPYRIGHT 2006, 2007, 2008,
2009 JAMES R, STUTZMAN, AIA, INDIANAPOLIS,
BID PACKAGE N0. 3
CONSTRUCTION ISSUE SET
Print Date Sheet Issue Date
07/22/10 04/01 /10
Drawn By Checked By
MAR PCB
Last Revision Date:
O0 .
O
O
O
O
O
Project Number:
Parcel 7C-1
Sheet Title:
ELECTRICAL SECOND
FL�OR CONTROL
LEVEL
Sheet Number: