Loading...
HomeMy WebLinkAbout198_SVC-011-SYMBOLLEGEND (Const Issue 7-22-2010).PDF� 3 �a � �p Z W � W � J J 0 m � � � � 0 U � DEVICE IDENTIFICATION NUMBER DEVICE DESIGNATION ZONE DESIGNATION (IF APPLICABLE) NOTE: SEE DEVICE DETAIL AND WIRE ROUTING SCHEDULE FOR DETAILS SYMBOL DESCRIPTION MICROPHONE LEVEL — GROUP A M2 Microphone Receptacle — 2 circuit MMP Monitor Microphone — 1 circuit LINE LEVEL — GROUP B PS 1 Powered Loudspeaker Receptacle— 1 circuit Note: Provide one 120V 20A AC IG ckt adjacent to each �PS 1 � device Note: Switching of AC circuits for "PS1 � devices will be controlled by SCC—supplied equipment within ARR VIDEO AND R/F LEVEL — GROUP D IRE Infrared Emitter Receptacle— 1 Circuit (loop—through) Note: All °IR° receptacles shall have an adjacent 120V 15A non—isolated Ground Circuit Power consumption per �IR� device < 40w MV Modulated Video System Reciever Receptacle Note: All �MV� receptacles shall have an adjacent 120V 15A non—isolated Ground Circuit Power consumption per "MV" device < 80w CV2 Closed Circut Video System Receptacle — 2 Ckt Note: All �CV2� receptacles shall have an adjacent 120V 15A non—isolated Ground Circuit Power consumption per "MV" device < 80w CV4 Closed Circut �deo System Receptacle — 4 Ckt Note: All �CV4� receptacles shall have an adjacent 120V 15A non—isolated Ground Circuit Power consumption per "MV" device < 80w INTERCOM LEVEL — GROUP E H4 Intercom Receptacle— 4 circuit HM House Manager's Panel SOUND SYSTEM LOUDSPEAKER LEVEL — GROUP F S 1 Sound System Loudspeaker Receptacle— 1 connector 2 circuit S2 Sound System Loudspeaker Receptacle— 2 connector 4 circuit S4 Sound System Loudspeaker Receptacle— 4 connector 8 circuit UBS Under—Balcony Loudspeaker— 8� Recessed Mount 70.7 VOLT COMMUNICATION SYSTEM LOUDSPEAKER LEVEL — GROUP G SCA Monitor/Page Speaker (70V)— 8n Recessed #—(indicates paging zone) Mount Electrical Enclosure: AMK Innovations BC8-7 SCB Monitor/Page Speaker (70V)— 8� Surface Ceiling #—(indicates paging zone) Mount Electrical Enclosure: Atlas Sound SE175-4 SSW Monitor/Page Speaker (70V)— 8" Surface Wall #—(indicates paging zone) Mount Electrical Enclosure: Atlas Sound SE175-4 SSA Monitor/Page Speaker Receptacle (70V) #—(indicates paging zone) V Monitor/Paging Volume Control (70V) VC Monitor/Paging Volume Control (70V) w/Paging Disable Switch NOTE: ALL DEVICES IN THIS CATEGORY ARE TO BE LOOPED THROUGH DEVICES IN THE SAME ZONE, THEN TO COMMUNICATIONS RACK ROOM. SYMBOL DESCRIPTION SOUND & COMMUNICATION SYSTEM MULTIPLE LEVEL PANELS — VARIOUS TE: SEE DEVICE DETAIL AND WIRE ROUTING SCHEDULE FOR PANEL DETAILS R## Sound & Communication Combination Panel Recording System Microphone Input Panel SYMBOL DESCRIPTION SOUND & COMMUNICATION SYSTEM A—C POWER RECEPTACLES SHOWN FOR REFERENCE ONLY — ALL DETAILS PER ELECTRICAL SPEC L/50q A—C NEMA L5-20 Duplex 1 ckt, 20A, Receptacle— IG S&C Isolated Ground Type L/ Surface Mounted Adjacent to an S&C Device Type M/ On Self—Powered Loudspeaker Panel A—C QUAD Receptacle— 1 ckt, 20A S&C Isolated Ground Type A/ Surface Mounted adjacent to an S&C Device Type B/ Flush Mounted adjacent to an S&C Device A—C DUPLEX Receptacle— 1 ckt, 20A S&C Isolated Ground Type C/ Surface Mounted adjacent to an S&C Device Type D/ Flush Mounted adjacent to an S&C Device Type E/ Surface Mounted with Waterproof Cover Type F/ Recessed adjacent to an S&C Device in Floor Box A—C DUPLEX Receptacle— 1 ckt. Standard Safety Ground Note: These ckts may originate from any Power Panel Note: See "MVr »CV2 ; �CV4n & �IRE; above for power requirements Type G/ Surface Mounted adjacent to an S&C Device Type H/ Flush Mounted adjacent to an S&C Device Type I/ Recessed for use with LCD TVs JUNCTION BOXES Type J/ 20A IG Circuit in Junction Box adjacent to S&C Device or Rack Type K/ 20A Std Circuit in Junction Box adjacent to S&C Device or Rack DIVERSITY DESIGNATION 100q [20A Typical Load] 50� 10A Typical Load] 25q 5A Typical Load 10q 2A Typical Load TYPE DESCRIPTION MFG / CAT No. O.D. (in.) AREA (in.) NOTES MICROPHONE LEVEL — GROUP A A 1 1x24 AWG twisted quad. copper strand shield Mogami 2820 0.197 0.030 (1 ch.) (16x37 stranding) LINE LEVEL — GROUP B B 1 1 x22 AWG twisted quad. mylar shield Belden 1800B 0.135 0.014 (1 ch.) (7x30 strand�ng) SPARE — SOUND SYSTEM — GROUP C Empty conduit only. VIDEO & RF LEVEL — GROUP D D 1 4x24 AWG twisted pair skew—free UTP cable Belden 7989R 0.365 0.060 RF Video Receiver System Line (MAN) D2 75 ohm Precision Video Coaxial Cable Belden 9116 0.270 0.057 Production Video Line (CCTV) (18 AWG solid center cond. & double copper braided shield) D3 75 ohm RG-6/U Type Low Belden 1694A 0.275 0.059 Word Clock / MADI / HD—SDI Loss Digital Coax�al Cable (18 AWG and Copper Braid Shield) D5 50 ohm RG-58A/U Type B'cast Coaxial Cable Belden 9311 0.195 0.030 Infrared Emitter (RF signal only) (20 AWG stranded cntr. cond.(19x32) & mylar w/ copper braid shield) D6 50 ohm RG-8/U Type B'cast Coaxial Cable Belden 9914 0.405 0.129 RF Microphone System Antenna (10 AWG solid center cond. & mylar w/ copper braid shield) INTERCOM LEVEL & DC CONTROL — GROUP E E4 4x20 AWG twisted .pair, mylar shield Belden 1815A 0.384 0.116 Production Intercom (4 ch.) (7x30 stranding) E20 4x22 AWG twisted pair, unshielded Belden 9746 .281 0.062 Sequential Power System Voltage chrome PVC 'acket 7x30 strandin J � 9) E22 2x22 AWG twisted pair, unshielded Belden 9744 .244 0.047 Sequential Power System Switching chrome PVC 'acket 7x30 strandin Control S stem Volta e J � 9) Y 9 LOW VOLT/IMPEDANCE LOUDSPEAKER LEVEL — GROUP F F1 12 AWG THHN—THWN stranded copper TBD 0.13 0.013 Low Volt/Impedance Loudspeaker 1 cond.) bu�ld�n w�re, one conductor (Used �n pa�rs only — DO NOT IST) 65x30 stranding) 70.7 VOLT LOUDSPEAKER LEVEL — GROUP G G 1 2x 18 AWG multiconductor cable Alpha 1897 0.2 0.031 70.7 Volt Communication System (16x30 stranding) Loudspeaker (1 ckt.) G2 3x18 AWG multiconductor cable Alpha 1898 0.21 0.035 70.7 Volt Volume Control (1 ckt.) (16x30 stranding) SPARE — COMMUNICATION SYSTEM — GROUP H Empty conduit only FIBER OPTIC LEVEL — GROUP J J 1 Fiber Optic Cable Multi—Mode Belden PTD6002 .184 0.051 Digital Audio J2 Fiber Optic Cable Single—Mode Belden M9D042 .255 0.051 Digital Audio J3 4x24 AWG twisted pair, category 6 Belden 1872A 0.200 0.031 Digital Audio ALLOWABLE CONDUIT TYPES: 1. ELECTRIC METALLIC CONDUIT (EMT) 2. GALVANIZED RIGID STEEL CONDUIT (GRS) 3. PVC—COATED RIGID STEEL CONDUIT IN CONCRETE SLAB NOTE: PVC CONDUIT SHALL NOT BE ALLOWED FOR ANY SOUND & COMMUNICATION SYSTEMS WIRING. NO EXCEPTIONS ! MINIMUM SEPARATION REQUIRED BETWEEN SOUND & COMMUNICATION SYSTEM CONDUIT SIGNAL LEVELS SPARE — INTERCOM SOUND SYSTM 70.7 VOLT SPARE — FIBER ISOLATED WIRING MICROPHONE LINE SOUND R/F LEVEL & LOUDSPEAKER LOUDSPEAKER COMM. OPTIC GROUND SIGNAL LEVEL LEVEL LEVEL SYSTEM LEVEL DC CONTROL LEVEL LEVEL SYSTEM LEVEL A—C POWER GROUP — A GROUP — B GROUP — C GROUP — D GROUP — E GROUP — F GROUP — G GROUP — H GROUP — J LEVEL MICROPHONE LEVEL GROUP — A ADJACENT 6" 6" 9" 12" 15" 18" 18" ADJACENT 24" LINE LEVEL GROUP — B 6" ADJACENT ADJACENT 3" 6" 9" 12" 12" ADJACENT 18" SPARE — SOUND SYSTEM GROUP — C 6" ADJACENT ADJACENT 3" 6" 9" 12" 12" ADJACENT 18" R/F LEVEL GROUP — D 9" 3" 3" ADJACENT 3" 6" 9" 9" ADJACENT 15" INTERCOM LEVEL & DC CONTROL 12" 6" 6" 3" ADJACENT 3" 6" 6" ADJACENT 12" GROUP — E SOUND SYSTEM LOUDSPEAKER LEVEL 15" 9" 9" 6" 3" ADJACENT 3" 3" ADJACENT 9" GROUP — F 70.7 VOLT LOUDSPEAKER LEVEL 18" 12" 12" 9" 6" 3" ADJACENT ADJACENT ADJACENT 6" GROUP — G SPARE — COMM. SYSTEM GROUP — H 18" 12" 12" 9" 6" 3" ADJACENT ADJACENT ADJACENT 6" FIBER OPTIC LEVEL GROUP — J ADJACENT ADJACENT ADJACENT ADJACENT ADJACENT ADJACENT ADJACENT ADJACENT ADJACENT ADJACENT ISOLATED GROUND A—C POWER LEVEL 24" 18" 18" 15" 12" 9" 6" 6" ADJACENT ADJACENT MINIMUM SEPARATION REQUIRED BETWEEN SOUND & COMMUNICATION SYSTEM CONDUIT AND ALL OTHER CONDUIT — PRODUCTION LIGHTING — --------------- AC POWER --------------- WIRING CONDUIT 120 VOLT 277 VOLT DIMMED ALL 277/480 VOLT SIGNAL LEVEL TYPE COMPOSITE SIGNAL / BRANCH BRANCH LIGHTING MOTOR FEEDER VIDEO TTL VIDEO CIRCUITS CIRCUITS CIRCUITS CIRCUITS CIRCUITS EMT/IMC/GRSC 9" 12" 36" 36" 36" 36" 36" MICROPHONE LEVEL GROUP — A PVC IN SLAB -------- PVC CONDUIT IS NOT ACCEPTABLE FOR USE WITH MICROPHONE LEVEL WIRING! -------- EMT/IMC/GRSC 3" 6" 24" 24" 24" 24" 24" LINE LEVEL GROUP — B PVC IN SLAB -------- PVC CONDUIT IS NOT ACCEPTABLE FOR USE WITH LINE LEVEL WIRING! -------- EMT/IMC/GRSC 3" 6" 24" 24" 24" 24" 24" SPARE — SOUND SYSTEM GROUP — C PVC IN SLAB -------- PVC CONDUIT IS NOT ACCEPTABLE FOR USE AS MICROPHONE LEVEL SPARE CONDUIT! -------- EMT/IMC/GRSC ADJACENT 3" 15" 15" 15" 15" 15" RF LEVEL GROUP — D PVC IN SLAB -------- PVC CONDUIT IS NOT ACCEPTABLE FOR USE WITH RF LEVEL WIRING! -------- ROUTING EMT/IMC/GRSC 3" ADJACENT 12" 12" 12" 12" 12" INTERCOM LEVEL & DC CONTROL GROUP — E PVC IN SLAB -------- PVC CONDUIT IS NOT ACCEPTABLE FOR USE WITH INTERCOM & DC CONTROL WIRING! -------- EMT/IMC/GRSC 6" 3" 12" 12" 12" 12" 12" LOW VOLT LOUDSPEAKER GROUP — F PVC IN SLAB -------- PVC CONDUIT IS NOT ACCEPTABLE FOR USE WITH LOW VOLT LOUDSPEAKER WIRING! -------- EMT/IMC/GRSC 9" 6" 9" 12" 12" 12" 12" 70.7 VOLT LOUDSPEAKER GROUP — G PVC IN SLAB -------- PVC CONDUIT IS NOT ACCEPTABLE FOR USE WITH 70.7 VOLT LOUDSPEAKER WIRING! -------- EMT/IMC/GRSC 15" 12" ADJACENT ADJACENT 12" 12" 12" ISO GND AC POWER PVC IN SLAB -------- PVC CONDUIT IS NOT ACCEPTABLE FOR USE WITH ISO GROUND WIRING! -------- ARTEC DESIGN AND PLANNING SERVICES FOR PERFORMING ARTS FACILITIES 114 WEST 2GTH STREET 12TH FLOOR NEW YORK NEW YORK USA 10001-6812 TEL: +1(212) 242 0120 FAX: +1(212) 645 8635 www.ArtecConsultants.com i��•���� FOR INFORMATI4N ONLY. REFER TO ELECTRICAL AND ARCH ITECTU RAL DRAWI NGS DATE: REVISIONS: DRAWN BY: SDP SCALE: NTS PROJECT NUMBER: 3796 oATE: 11 J U N 10 CHECKED BY: PSP PRo�ECT: CARMEL THEATER CARMEL, IN No. TiT�E: SOUND & VIDEO COMMUNICATION DEVICE LEGEND AND CONDUIT SEPARATION DRAWING NUMBER: SVC-011