HomeMy WebLinkAbout15060018 Building PlansA0.1 ARCHITECTURAL SPECIFICATIONS 05 - 0 6 - 1 5 BW S Is s u e f o r P e r m i t / C o n s t r u c t i o n : : : De s c r i p t i o n Is s u e d Da t e Ma r k DR A W I N G I S S U E & R E V I S I O N S T A T U S ©  2015 CARLSON ASSOCIATES, INC. CHK'D BY DRAWN BY PROJECT # 15-20-151500 NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made only by the Architect. 14 9 0 1 Q u o r u m D r i v e , S u i t e 5 9 5 Da l l a s , T X 7 5 2 5 4 ww w . c a r l s o n - d c . c o m Te l : 9 7 2 . 2 5 0 . 3 9 7 2 F a x : 9 7 2 . 2 3 3 . 7 5 7 5 Ca r l s o n co n s u l t i n g . d e s i g n . c o n s t r u c t i o n Gi a n t E a g l e S t o r e 6 5 5 0 11 5 0 5 I l l i n o i s S t r e e t Ca r m e l , I N In t e r i o r I m p r o v e m e n t s No. AR10400002 CYUG .TOR O T E C TIHCRA SIGER TERE D A N AIDNI STATE OF Date: 05/06/15 A1.1 PLANS 05 - 0 6 - 1 5 BW S Is s u e f o r P e r m i t / C o n s t r u c t i o n ROOM FINISH SCHEDULE NUMBER ROOM NAME MATL.BASE NORTH EAST SOUTH WEST FLOOR WALLS CEILING DOOR HARDWARE LEGEND ID DESCRIPTION QTY.TYPE LOCK TYPE LEVER/PULLS CLOSER TYPE STOP TYPE KEY CODE NOTES ROOM FINISH LEGEND DESCRIPTION MANUFACTURER MODEL COLOR NOTES Ceiling Walls Base Floor Paint Casework NOMINAL SIZE DOOR SCHEDULE DOOR FRAME DOOR DATA MARK WI D T H HE I G H T TH I C K N E S S JA M B D E P T H HE A D D E T A I L JA M B D E T A I L FR A M E T Y P E MA T E R I A L FI N I S H HW S E T MFR MODEL NO.MATERIAL FINISH NOTES : : : De s c r i p t i o n Is s u e d Da t e Ma r k DR A W I N G I S S U E & R E V I S I O N S T A T U S ©  2015 CARLSON ASSOCIATES, INC. CHK'D BY DRAWN BY PROJECT # 15-20-151500 NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made only by the Architect. 14 9 0 1 Q u o r u m D r i v e , S u i t e 5 9 5 Da l l a s , T X 7 5 2 5 4 ww w . c a r l s o n - d c . c o m Te l : 9 7 2 . 2 5 0 . 3 9 7 2 F a x : 9 7 2 . 2 3 3 . 7 5 7 5 Ca r l s o n co n s u l t i n g . d e s i g n . c o n s t r u c t i o n Gi a n t E a g l e S t o r e 6 5 5 0 11 5 0 5 I l l i n o i s S t r e e t Ca r m e l , I N In t e r i o r I m p r o v e m e n t s No. AR10400002 CYUG .TOR O T E C TIHCRA SIGER TERE D A N AIDNI STATE OF Date: 05/06/15 LP B - 0 A1.2 ELEVATIONS 05 - 0 6 - 1 5 BW S Is s u e f o r P e r m i t / C o n s t r u c t i o n FACE OF EXISTING WALL : : : De s c r i p t i o n Is s u e d Da t e Ma r k DR A W I N G I S S U E & R E V I S I O N S T A T U S ©  2015 CARLSON ASSOCIATES, INC. CHK'D BY DRAWN BY PROJECT # 15-20-151500 NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made only by the Architect. 14 9 0 1 Q u o r u m D r i v e , S u i t e 5 9 5 Da l l a s , T X 7 5 2 5 4 ww w . c a r l s o n - d c . c o m Te l : 9 7 2 . 2 5 0 . 3 9 7 2 F a x : 9 7 2 . 2 3 3 . 7 5 7 5 Ca r l s o n co n s u l t i n g . d e s i g n . c o n s t r u c t i o n Gi a n t E a g l e S t o r e 6 5 5 0 11 5 0 5 I l l i n o i s S t r e e t Ca r m e l , I N In t e r i o r I m p r o v e m e n t s No. AR10400002 CYUG .TOR O T E C TIHCRA SIGER TERE D A N AIDNI STATE OF Date: 05/06/15 G 1 1 1 1 0 ' 6'- 3 " 4'- 1 1 " G G :::Description Issued Date MarkDRAWING ISSUE & REVISION STATUS ‹20 15 CARLSON ASSOCIATES, INC.CHK'D BY MWDRAWN BY GWPROJECT # 15-20-151500 NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made only by the Architect.14901 Quorum Drive, Suite 595 Dallas, TX 75254 www.carlson-dc.com Tel: 972.250.3972 Fax: 972.233.7575 Carlson consulting.design.constructionGiant Eagle Store 6550 11505 Illinois Street Carmel, IN Interior Improvements Tel. 770.414.1628 Fax 770.414.6024 SBE Project No. 15048Norcross, Georgia 300925655 Peachtree Parkway, Suite 100Issue for Permit /Construction 05-06-15 E100FLOOR PLANS - ELECTRICAL x x x x x 1. 2. 3. 4. 5. 6. 7. 8. 9. � �. 11. 12. 13. ELECTRI CAL REN OVATI ON N OTES AL� WORK TO BE DONE BY LICENSED E�ECTRICAL CONTRACTOR. AL� WORK TO CONFORM TO AL� FEDERAL, STATE AND LOCAL CODES. ELECTRICAL CONTRACTOR TO TO RUN FEEDER CABLES FOR NEW PANEL FROM MARKET'S MAIN ELECTRICAL DISTRIBUTION PANEL. MAIN BREAKER AND CONDUITS BY SUPERMARKET. ELECTRICAL CONTRACTOR TO DETERMINE HOW CIRCUITS ARE WIRED IN PANEL SO PHASES ARE BALANCED AS EVEN AS POSSIBLE. TYPED ELECTRICAL PANEL DIRECTORY TO BE FILLED IN COMPLETELY BY ELECTRICAL CONTRACTOR. ALL ELECTRICAL RECEPTACLES AND DATA / PHONE JACKS INSTALLED IN THE MILLWORK SHALL BE UNDER THE COUNTER AND CUT INTO THE INSIDE FACE. ALL ELECTRICA� WIRING TO BE RUN IN RIGID EMT CONDUIT FROM JUNCTION BOX TO TERMINATION POINT IN WORK ROOM. ELECTRICAL CONTRACTOR TO PROVIDE TEMPORARY POWER AND LIGHTING DURING ALL PHASES OF CONSTRUCTION. ELECTRICAL CONTRACTOR TO OBTAIN OWNERS APPROVAL FOR ALL MATERIAL REQUIRED AND TO WARRANTY ALL SAID MATERIA� FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ELECTRICAL INSPECTION. ELECTRICAL CONTRACTOR TO CONSULT WITH BANK ON E�ECTRICAL REQUIREMENTS FOR INTERIOR AND EXTERIOR SIGNAGE. ELECTRICAL CONTRACTOR TO SUPPLY ANd INSTALL ALL COVER PLATES. FINISH TO BE STAINLESS STEEL. (CONFIRM WITH BANK) ELECTRICAL CONTRACTOR TO DRILL HOLES FOR ELECTRIC ACCESS IN MILL WORK AS REQUIRED. ELECTRICIAN TO SUPPLY AND INSTALL GROMMETS AS REQUIRED. CONFIRM FINISH) ELECTRICAL CONTRACTOR TO VERIFY VOLTAGE ANd SUPPLY AND INSTALL VOLTAGE REGULATOR AND/OR BUCK BOOSTER WHERE REQUIRED. 120V CIRCUIT FOR TC-1 BK-25 � Neutral �ine Neutral NOTES: 1 0 NOTES: �� � TC-1. E SWITCHING FOR SIGNAGE )L. ALL WIRING TO BE MINIMUM NO 12 AWG IN 3/4" EMT. SIGNAGE AND SIGNAGE INSTALLATION TO BE BY OWNERS SIGN CONTRACTOR. COORDINATE INSTALLATION REQUIREMENTS SIGN CONTRACTOR. I�TERIOR SIGNAGE WIRING DIAGRAM NO SCALE PROVIDE DISCONNECT FOR MANUAL SIGNAGE CONTROL. ALL WIRING TO BE MINIMUM NO 12 AWG IN 3/4" EMT. SIGNAGE AND SIGNAGE INSTAL�ATION TO BE BY OWNERS SIGN CONTRACTOR. COORDINATE INSTALLATION REQUIREMENTS SIGN CONTRACTOR. �\ EXTERIOR SIGNAGE WIRING DIAGRAM E-101/ NO SCALE INTERIOR SIGNAGE (BY OTHERS) PROVIDE PHOTOCE�L LIGHT SENSOR AT EXTERIOR FOR SIGNAGE CONTROL. EXTERIOR SIGNAGE (BY OTHERS) . � : t • , . � � ° . ��,�� . IIII � II II�IIIIIIIIIIIIIII �I II� � IIIIIIIIIIIIIIIIIIIII ; �� 1 1 � . . . . � _ . ; � .� I� s = s = � � - • t � '� ' � �t : � � : ' � �� '�i � - * 11 , � i� ! � i f : � I i S ■ ����� I I�� !i � � l• � . . .; '� i : "�',..'� � � . �'� � � � � ; � �� � � i �I`�� � ���� � ���� � ` ` ' • 1 ' � ` ' � � �� � ' �����l��� �������' ;���� i . . � . � - - �� • . - . �� 1111' s ��- ��� . . .. . . , e . . . �..��.. �I� • '�� ' � ' ` ' ' ;' ` � '� f � ����i`��������������IIIII■ .`r � �.. �: � �' "' � f ' ' • ' � � ! ' � i ._� i � �_ i _i � � � ' ��� � �� i : ' •. ' : '" ...."i �l # � � ! � �� � � � � � � : ■ �� ;i •" i � l •'. � �ll i � � �� � l � i : �� ... �. � � .: � �. . y. � � .. � s � .� r � . s ;. � � �. i y �. #. s � : �. s ., l. ��, �.. l * .,. . � .: s. . . f� f � � :�. . 1 ; l +� -1 � . i '. � + i i ..�. � a � i i � � 1 � � i � � � � ; ; � . � � i � . . • • . . . i` � '1 ` i i � ' + ''�•t ' i �. i i �:i • ! '' i i, # �, � �. . y . � y . y.i � . i a.. c•a � � � �1� � � i i� c';� ■, � � • 1 � � � i;� t 1 i . �, , . � �. i � * . a:i ' i � i' i�� � � � i •�� •'; �+ . , �� '.�■ . . ; . � i •��•� � � . � � � �i f • � � � f. � s � �. .� � * ; y. . i . � l � ' , �. �� � � " 1 �� l. # � s + s l. :� � s�. .�� . �� � � i � '. .. � : �. � � � � � ! ) •� � �. � � � l � � # ;. ]� ..� ] � i ��� �..� � t�� .� �� � � i � :i �. .. ' � ' �� � . � � �:�� �� � � � � . � i� � i� : �. �. . � ;. ; � � �. . � � . i i� � ' � i 1 �� � ' � 1 ' � . � . � � . � �. �� � I�� � �. f' �� � �� ' ' ' •. � �` •�i •� ` ''# ! i� • : ! i ...• � ' � '' i i •#�! ' + '� i ' i • •, ��, �. , � ; . 11, ' # : � •' � '' � � � � � � � i � � � 1 � � ���� 1 r + ';i ' '. � � i_• �� '� ' � � � 1. � . � �. . .i : � � i 1 �. . .. � .. �.. Y . ... .. ! �. � � � i � i � �s � t ■ � � ■s� � � y � �. • sy . ELECTRI CAL LEGEN D A-1,3,5 A-1,3,5, ADJACENT TO ARROW INDICATES HOMERUN OF CIRCUITS 1,3,5 TO PANEL A. MARKS ACROSS � RACEWAY RUNS INDICATE THE NUMBER OF #12 AWG CONDUCTORS. UNLESS NOTED NO MARKS INDICATE B a TWO #12 AWG CONDUCTORS. MULTI-WIRE BRANCH CIRCUITS SHAL� BE PROVIDED WITH DEDICATED NEUTRALS PER PHASE; DO NOT SHARE NEUTRAL CONDUCTORS. NUMERAL AND LOWER CASE LETTER INDICATES CIRCUIT CONNECTION AND SWITCH LEG DESIGNATION RESPECTIVELY. UPPER CASE LETfER INDICATES FIXTURE TYPE. NOTES: 1. ALL SYMBOLS INDICATED IN THIS LEGEND MAY NOT BE USED ON THE PLANS. 2. DIMENSIONS INDICATED IN LEGEND ARE TO BOTTOM OF OUTLET OR EQUIPMENT, UNLESS OTHERWISE INDICATED. DIMENSIONS INDICATED ARE TO COMPLY WITH ACCESSIBI�ITY CODE(S). 3. REFER TO SPECIFICATIONS FOR FINISH COLOR/TYPE OF DEVICES AND DEVICE PLATES; WHERE NOT INDICATED IN SPECIFICATIONS, CONFIRM FINISH REQUIREMENTS WITH ARCHITECT OR OWNER. 4. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHTING FIXTURES. XXXX MECHANICAL EQUIPMENT TAG - REFER TO MECHANICAL EQUIPMENT ELECTRICAL CONNECTION X SCHEDU�E FOR ADDITIONAL INFORMATION AND BRANCH CIRCUIT REQUIREMENTS. /'-"\ RACEWAY INSTALLED CONCEALED IN WALLS AND/OR ABOVE CEILING. �-�' -�� RACEWAY INSTALLED CONCEALED BELOW FLOOR, SLAB, OR GRADE. '� � PANELBOARD - FLUSH OR SURFACE MOUNTED, VOLTAGE AS INDICATED IN SCHEDULE. "WP" INDICATES AN WEATHERPROOF ELECTRICA� DEVICE/COVER. �� CEILING OUTLET AND FLUORESCENT 2x4 FIXTURE (HALF SHADED INDICATES NIGHT LIGHT FIXTURE. � Q CEILING OUTLET AND FLUORESCENT 2x2 FIXTURE (HALF SHADED INDICATES NIGHT �IGHT FIXTURE. �� DOWNLIGHT FIXTURE (SHADED INDICATES EMERGENCY FIXTURE, REFER TO LIGHTING FIXTURE SCHEDU�E FOR EMERGENCY BACK-UP) � EMERGENCY EGRESS FIXTURE, WITH BAl-fERY BACKUP. $ SING�E POLE TOGG�E SWITCN - 48" A.F.F. � DUPLEX RECEPTACLE - 18" A.F.F. OR AT HEIGHT INDICATED. NEMA-5-20R � DUPLEX 20A GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE - 18" A.F.F., OR AT HEIGHT INDICATED. "XX'� DUPLEX 20A RECEPTAC�E - XX" A.F.F. AS NOTED ON PLANS. �Q QQ -� 0 JUNCTION BOX - CEILING/WALL/FLOOR MOUNTED. � PEDESTAL FLOOR BOX WITH UTILITIES INDICATED. REFER TO NOTES ON DRAWINGS FOR REQUIREMENTS. DATA OUTLET 18" A.F.F. UNLESS OTHERWISE NOTED - 4"x4" BOX, PLASTER RING, AND 1" CONDUIT D FROM BOX TO ACCESSIBLE CEILING, NETWORK CABLING AS SPECIFIED OR AS IND►CATED. "X" (X) INDICATES QUANTITY OF CONNECTIONS/CABLES PER OUTLET. NO "X" INDICATES (2) CONNECTIONS/CABLES, UN�ESS OTHERWISE INDICATED. ► TE�EPHONE (ANA�OG) OUT�ET 18" A.F.F. UN�ESS OTHERWISE NOTED - 4"x4" BOX, P�ASTER RING, AND 1" CONDUIT FROM BOX TO ACCESSIBLE CEILING, CABLING AS SPECIFIED OR AS INDICATED. OTC-(X) TIME CLOCK LIGHTING CONTROLLER - ASTRONOMICAL, DUAL CHANNEL, DUAL SCHEDULE. EL72 SERIES BY PARAGON OR EQ. "X" INDICATES TIME CLOCK NUMBER DESIGNATION. �oannfLocATio�: BA�vK ��oRT� wA��� FEQ F�OM: SPD2 AIC FtATI(VG: 10kAIC (SEE NOTE 3) voL-r��� � P�as�: �2ai208v-�� An�P��A��: �ooA MOl1NTING: SURFACE MAIN: MCB DESCRIPTItJN KVA BKR PHASE BKR KVA DESCFtiPTION LiGHTS (SEE NOTE 1) 0.1 20/1 1 A 2 20/2 0.4 RADIANT CEILING HEATER LIGNTS (SEE NOTE 2) 0.7 20/1 3 B 4 --- �.4 WP RTU REGEPTACLE 0.2 2Q/1 5 C 6 2fli1 0.5 OFFICE RECEPiACLE (JFFICE RECEPTAC�E 0.4 20I1 7 A 8 20/1 0.5 (JFFiGE RECEPTACLE SPARE 20/1 9 B 10 20/1 0.2 TEL�ER RECEPTACLE TELLER RECEPTACLE 0.4 20/1 11 C 12 20l1 I��UM WALL 0.6 20/1 'l3 A 'l4 2fl/1 1.2 �ULKNEAD SIGN (SEE NOTE 2) TELLER RECEPTAC�E 0.2 20I1 15 B 16 20/1 �.2 WCJRK ROOM FtEGEPTAGLE wt��� �oon� ��cE�TACL� �s�� �o�r� �} o.� 20/1 7� c 1s 2oi7 0.4 WORK ROOM RECEPTACLE (SEE NOTE 1) W�RK RO�M RECEPTACLE Q.2 2Q/1 19 A 20 20l1 Q.6 ATN1 RECEPTACLE (SEE NOTE 1) SPARE 20/1 2'1 B 22 2fl/1 0.2 WORK RtJC�M RECEPTACLE (SEE NC}TE 1} LCD SCREENS 0.4 20I1 23 C 24 20/1 0.2 SEGURITY MCJNITCIR TiME CLOCK TG-1 0.1 20/1 25 A 26 20/1 1.2 EXTERIOR S1GN sPACE --- 2a B �$ 60�2 s.� �Tu-� SPACE --- 29 C 30 --- 3.5 CUNNECTED D.F. DEMAND EXISTING LOAD O.Q x 1.25 0.0 COOLiNG: 7.0 x 1.00 7.0 HEATiNG: 0.8 x 0.00 0.0 KVA LOAD BALANCE PER PNASE: KITCHEN: 0.0 PER NEC 220.56 0.0 PNASE A: 101.2% LIGHTING: 3.7 x 1.25 4.7 PHASE B: 92.0% MOTORS: 0.0 x 1.00 0.0 PHASE G: 1Q6.8% LARGEST MOTOR 0.0 PER NEC 220.18(A) 0.0 (�THER: O.i x 1.00 0.1 HIGFiEST PNASE LOAD RECEPTACLES: 4.8 PER NEC 220.44 4.8 49.2 AMPERES CONNECTED KVA 16.4 DEMAND KVA: '16.6 AVERAGE CONNECTED AMPS 45.7 DEMAND AMPS: 49.2 NOTES: (1}- PROViDE WITH �OCK-ON TAB. (2)- CIRCUITENG TO BE THROUGH TIME CLOCK (TC-1). SGHEQULE iNTERIOF2 LIGHTING FOR 7 QAY BUSiNESS HOURS (3)- COQRDINATE SHORT CIRCUIT RATING WITH FAULT CURRENT AVAILABLE FROM FEEDER. (4)- CIRCUITiNG/PANEL SCHEDULE SHOWN IS DIAGRAMMATIC. EC RESPONSIBLE FOR FINAL CiRCUITiNG, PANEL SIZING, LAYOUTlLOADiNG. (5)- EC TO COORDI(�ATE FINA� L(JCATION AND POWER REQUiREMENTS OF ALL EQUIPMENT WITH OWNER. SPENCER BRISTOI ENC�INEERING, INC. 5655 PFncl�lrzFF PARkway, SuirF 100 Norzca�ss, GeoaGin 3009`Z TeL 770.414.1628 Fnx 770.414.6024 SBE PaojEcr No. 15048 NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made onty by the Architect. �����\��J�l��������1�1�eJl`l'�� GENERAL SHOU�D A BIDDER FIND DISCREPANCIES IN, OR OMISSIONS FROM, THE DRAWINGS OR SPECIFICATIONS, OR SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHOULD AT ONCE NOTIFY THE ARCHITECT, WHO WILL SEND WRITTEN INSTRUCTIONS TO ALL BIDDERS. IF THESE ARE IGNORED BY THE CONTRACTOR, HE WILL BE RESPONSIBLE FOR FURNISHING THE PROPER OR WORKABLE EQUIPMENT AS NECESSARY. BEFORE SUBMITfING A BID, BIDDERS WILL BE HELD RESPONSIBLE TO HAVE VISITED THE SITE OF THE WORK AND FULLY INFORM THEMSELVES AS TO ALL EXISTING CONDITIONS AND LIMITATIONS, INC�UDING RU�ES, RATES AND FRINGE BENEFITS, TRAVE� PAY, AFFILIATION FEES AND TRANSPORTATION EXPENSE PREVAILING IN THE LOCAL LABOR MARKET. NO ALLOWANCE SNALL SUBSEQUENTLY BE MADE ON BEHALF OF THE BIDDER BY REASON OF ANY ERROR ON HIS PART. ADDENDA ANY INTERPRETATION, CORRECTIONS OR CHANGES OF THE DRAWINGS AND SPECIFICATIONS WIL� BE MADE ON�Y BY AN ADDENDUM DULY ISSUED BY THE ARCHITECT AND A COPY OF SUCH ADDENDUM WILL BE MAILED OR DELIVERED TO EACH PERSON OR FIRM. SCOPE OF CONSTRUCTION THE CONTRACT UNDER THESE SPECIFICATIONS INCLUDES ALL LABOR, MATERIAL, EQUIPMENT, AND SERVICES NECESSARY AND INCIDENTAL TO PROVIDE AND INSTALL IN P�ACE, FINISHED COMPLETE, UN�ESS OTHERWISE NOTED. A�� ELECTRICAL CONSTRUCTION IN ACCORDANCE WITH THESE SPECIFICATIONS AND ACCOMPANYING DRAWINGS, SUBJECT TO AND IN ACCORDANCE WITH ALL RULES AND REGULATIONS OF THE NATIONAL FIRE PROTECTION ASSOCIATION, NATIONAL ELECTRIC CODE, STATE AND MUNICIPAL CODES AND LOCAL POWER COMPANY. GENERAL AS FOLLOWS: • METERING ARRANGEMENT • POWER PANE�S • TRANSFORMERS • BRANCH WIRING • FEEDERS • LIGHTING FIXTURES AND LAMPS • TELEPHONE RACEWAY SYSTEM • WIRING OF EQUIPMENT FURNISHED BY OTHERS AND FINAL CONNECTIONS TO SAME • SECURITY RACEWAY SYSTEM EXAMINATION OF SITE BIDDERS SHALL EXAMINE CAREFULLY, THE ENTIRE SITE OF THE ELECTRICAL CONSTRUCTION. THEY SHALL MAKE ALL INVESTIGATIONS NECESSARY TO INFORM THEMSELVES THOROUGHLY AS TO FACILITIES FOR DELIVERING, PLACING AND USING THE NECESSARY EQUIPMENT AND MATERIALS AND RS TO ALL THE DIFFICULTIES INVOLVED IN COMPLETION OF ALL ELECTRICAL CONSTRUCTION IN ACCORDANCE WITH THE E�ECTRICAL SPECIFICATIONS AND DRAWINGS. DEMOLITION TAKE PARTICULAR NOTE OF THE DRAWINGS, BOTH GENERAL AND ELECTRICAL, TO DETERMINE THE AFFECTED AREAS OF THE EXISTING STRUCTURE. REMOVE ELECTRICAL APPURTENANCES IN TNE AFFECTED AREAS NOT TO BE REUSED INCLUDING WIRE, CONDUIT SWITCHES, OUTLETS, LIGHT FIXTURES, AND FITfINGS. IF ANY EXISTING ELECTRICAL ITEMS ARE TO BE REMOVED, EITHER PATCH AREA AS REQUIRED OR PROVIDE A BLANK COVERPLATE OVER BOXES TO REMAIN. ANY CONDUIT OR WIRING THAT IS NOT TO BE PERMANENTLY REMOVED AS NECESSARY AND REROUTED AND RECONNECTED AS REQUIRED. ITEMS REMOVED ABOVE SHALL BECOME THE PROPERTY OF THE OWNER UNLESS OTHERWISE NOTED. IF THE OWNER HAS NO USE FOR ANY ITEMS, REMOVE THEM FROM THE SITE. MAINTAIN THE CONTINUITY OF ANY PRESENT CIRCUITS THAT MAY BE INTERRUPTED BY THESE ALTERATIONS EVEN THOUGH THEY MAY NOT BE INDICATED ON THE DRAWING. FURNISH THE LABOR AND NECESSARY MATERIALS REQUIRED TO RESTORE THE CIRCUIT. WHERE CIRCUITS ARE �OOPED AND OUTLETS ARE REMOVED, MAKE ADJUSTMENTS AND CONNECTIONS TO RESTORE THE CIRCUITS. COORDINATION THE EXACT FIELD LOCATION OF WALLS, FLOORS, PARTITIONS, DOORS AND WINDOWS MAY VARY FROM THE LOCATIONS SHOWN ON THE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. PRIOR TO LOCATION OF S�EEVES, BOXES AND CHASES, FOR ROUGHING OF PIPING, CONDUIT, AND EQUIPMENT. THE CONTRACTOR SHALL CHECK PERSONALLY WITH THE GENERAL CONTRACTOR OR HIS REPRESENTATIVE TO DETERMINE THE EXACT FIELD LOCATION OF THE WALLS, FLOORS, DOORS, WINDOWS, AND PARTITIONS. IN ADDITION, THE CONTRACTOR SHALL DETERMINE THE EXACT DIRECTION OF DOOR SWING SO THAT LOCAL SWITCHES AND THERMOSTATS CAN BE INSTALLED AT THE �OCK SIDE OF DOORS, UNLESS SPECIFIED OTHERWISE. IT WILL BE THE SO�E RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROPERLY ROUGH FOR THE ELECTRICAL CONDUIT AND EQUIPMENT UNDER HIS CONTRACT. THE ELECTRICAL CONTRACTOR SHALL OBTAIN A SOURCE OF TEMPORARY POWER FROM THE EXISTING BUILDING PANELS. ARRANGE WITH THE OWNER FOR A SUITABLE SOURCE FOR TEMPORARY POWER. EXTEND POWER TO THE WORK AREA AND PROVIDE ADEQUATE GENERAL LIGHTING AND POWER OUT�ETS REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE WORK. ALL WORK TO CONFORM TO THE REQUIREMENTS OF OSHA. COORDINATE WORK WITH BUILDING TENANTS. ANY WORK WHICH MAY DISTURB OTHER TENANTS SHA�L BE PERFORMED DURING OFF-BUSINESS HOURS. PROCEDURE DUE TO THE SCHEMATIC NATURE AND SMALL SCALE OF THE ELECTRICAL DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL EXACT LOCATIONS, OFFSETS, FIl-fINGS, ACCESS PANE�S, PUL� BOXES, AND MISCEL�ANEOUS PARTS WHICH MAY BE REQUIRED TO FORM A COMPLETE THE DRAWINGS ARE GENERALLY INDICATIVE OF THE WORK TO BE INSTALLED. THIS CONTRACTOR SHALL CAREFULLY INVESTIGATE THE STRUCTURAL AND FINISH CONDITIONS AFFECTING THE WORK AND ARRANGE ALL WORK ACCORDINGLY. FURNISHING NECESSARY PARTS AND EQUIPMENT AS MAY BE REQUIRED TO MEET THE VARIOUS CONDITIONS. ALL MATERIALS AND EQUIPMENT INSTAL�ED BY THE CONTRACTOR SHAL� BE FIRMLY SUPPORTED AND SECURED TO THE CONSTRUCTION WHERE REQUIRED, WITH SUITABLE HANGERS AND ANCHORS OF TNE BEST QUA�ITY SPECIFICAL�Y DESIGNED FOR THE SERVICE REQUIRED. FINISHED OR UNFINISHED AREA - GENERAL DEFINITION FINISHED AREA: SHALL BE DEFINED AS ANY SPACE WITH THE WALLS EITHER TILED, P�ASTERED, COVERED OR PAINTED, EXCEPT CERTAIN CONCRETE OR CONCRETE BLOCK FOUNDATION WAL�S BELOW GRADE IN WHICH CHASES FOR LARGE VERTICA� PIPING WIL� NOT BE PERMITfED. WHERE THERE ARE CEILINGS IN FINISHED AREAS, ALL BOXES AND CONDUIT SHAL� BE CONCEALED ABOVE THE CEI�INGS UNLESS INDICATED "AT CEI�ING" IN WHICH CASE, BOXES AND CONDUIT SHAL� BE EXPOSED BELOW CEILINGS. AREAS WHERE BO�ifOM OF F�OORS OR ROOFS SLABS SERVE AS FINISHED CEILINGS SHALL BE CONSIDERED FINISHED AREAS. UNFINISHED AREAS: SHA�� BE DEFINED AS ANY SPACE WITHOUT A WALL FINISH (WITH OR WITHOUT CEI�INGS). WHEN IN DOUBT AS TO THE CLASSIFICATION OF A SPECIFIC SPACE, THE CONTRACTOR SHALL CHECK WITH THE ARCHITECT BEFORE ROUGH-IN. PROTECTION OF SERVICES THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, REPAIR, REPLACE AND MAINTAIN IN SERVICE, ANY UTILITIES, FACILITIES OR SERVICES (UNDERGROUND, ABOVE GROUND, INTERIOR OR EXTERIOR) DAMAGED, BROKEN OR OTHERWISE RENDERED INOPERATIVE DURING THE COURSE OF CONSTRUCTION. SHOP DRAWINGS THE CONTRACTOR SHALL FURNISH SHOP DRAWINGS, CATALOG CUTS, DATA SHEETS, ETC., TO COVER SPECIFIED INFORMATION FOR ALL ITEMS IN ANY WAY DESIGNED FOR THIS JOB. NONE OF THE FOLLOWING ITEMS SHALL BE INSTALLED IN THE CONSTRUCTION UNTIL FINAL APPROVAL HAS BEEN GIVEN BY THE OWNER. THIS CONTRACTOR SHALL CHECK SHOP DRAWINGS OF OTHER CONTRACTOR'S EQUIPMENT. TO ASCERTAIN PROPER �OCATION OF AL� EQUIPMENT AND CONNECTIONS, SUBMIT SNOP DRAWINGS, CATALOG CUTS, ETC., FOR THE FOLLOWING ITEMS: • LIGHTING AND POWER PANELS AND CABINETS • SWITCHES • LIGHTING FIXTURES • PLUG-IN STRIP • TRANSFORMERS CONDUIT INSTALLATION GENERAL: ALL WIRING SHALL BE RUN IN RIGID STEEL CONDUIT AND/OR ELECTRICAL METALLIC TUBING AS SPECIFIED HEREIN. WHERE THE SINGLE PO�E WORK IS USED ON BRANCH CIRCUITS, CIRCUIT WIRING MAY BE GROUPED IN ACCORDANCE WITH THE NEC. THE DRAWINGS ARE SCHEMATIC AND DIAGRAMMATIC AND INDICATE THE GENERAL METHOD OF INSTALLING ALL CIRCUIT WIRING AND THE OUTLETS WHICH ARE TO BE SUPPLIED.IF IT BECOMES NECESSARY TO CONNECT AN OUTLET TO A CIRCUIT OTHER THAN AS SHOWN OR RELOCATE AN OUT�ET, THIS SHA�� BE DONE WITHOUT ADDITIONAL CNARGE. THE SIZE AND GENERAL LOCATION OF THE VARIOUS FEEDERS ARE SHOWN ON THE DRAWINGS: HOWEVER, THE EXACT LOCATION AND ROUTING OF FEEDERS SHALL BE DETERMINED ON THE SITE BY THE CONTRACTOR. WHENEVER THE WORDS "CONDUIT" APPEARS HEREIN, IT SHALL REFER TO EITHER RIGID STEEL CONDUIT OR STEEL ELECTRIC METALLIC TUBING WHICHEVER IS APPLICABLE. NO CONDUIT SMALLER THAN 3/4" TRADE SIZE MAY BE USED. IN THE CASE OF FLEXIBLE CONDUIT. NO SIZE SMALLER THAN 1/2" O.D. MAY BE USED AT �IGHTWG FIXTURES, FANS, AND VARIOUS EQUIPMENT, AGAIN SIZED IN ACCORDANCE WITH NEC. MC CAB�E MAY BE USED IN CONCEALED AREAS AL�OWED BY NEC. ELECTRICAL METAL�IC TUBING (EMT): THE CONTRACTOR SHA�L FURNISH AND INSTAL� ELECTRICAL METALLIC STEEL TUBING IN ALL LOCATIONS EXCEPT WHERE METALLIC CONDUIT IS NOT PERMITTED TO INCLUDE THE FOL�OWING: • UNDERGROUND - USE PVC SCHEDULE. 40 • IN GRAVEL OR OTNER SUB-BASE FLOOR FILLS; HORIZONTAL RUNS IN CONCRETE FLOOR SLABS - USE PVC SCHEDULE. 40 • IN MASONRY WAL�S BE�OW GRADE • VERTICAL�Y IN POURED CONCRETE WAL�S • EXPOSED IN ANY WEATHERPROOF (WP) OR EXPLOSION PROOF (EP) AREA • CONCRETE FLOOR AND ROOF SLABS OR FLOOR FI�LS RIGID CONDUIT SHAL� BE INSTALLED IN ALL AREAS AND �OCATIONS WHERE EMT IS NOT PERMITTED. ALL APPLICABLE PORTIONS OF THE SPECIFICATION ON RIGID CONDUIT AND ITS INSTALLATION SHALL APPLY IN ITS ENTIRETY. EMT SHALL BE GALVANIZED OR SHERARDIZED AND COATED WITH ENAMEL BOTH INSIDE AND OUTSIDE. EACH LENGTH SHALL BEAR THE U.L. SEAL OF APPROVAL. IN ABOVE GRADE LOCATIONS, EMT WILL BE PERMITfED TO BE INSTAL�ED THROUGH WALL AND FLOOR CONSTRUCTION, IN CHASES, THROUGH JOISTS, AND IN ALL OTHER LOCATIONS, EXCEPT AS SPECIFIED ABOVE. WHERE RIGID CONDUIT IS INSTA�LED, THE CONDUIT MUST TERMINATE IN AN OUTLET BOX OR JUNCTION BOX WHERE THE TRANSITION TO EMT (AND VICE VERSA) MUST BE MADE. WNERE BOXES ARE USED ONLY FOR THE TRANSITION FROM TUBING TO CONDUIT (OR CONDUIT TO TUBING), THE CONTRACTOR SHALL A SUITABLE PLASTER RING AND A STAINLESS STEEL COVER PLATE. FLEXIBLE CONDUIT (METALLIC AND NON-METALLIC): ALL CONNECTIONS BETWEEN MOTOR JUNCTION BOXES AND CONDUIT OR JUNCTION BOXES SHALL BE MADE WITH SINGLE STRIP (GREENFIELD) OR APPROVED EQUAL GALVANIZED FLEXIBLE STEEL CONDUIT IN LENGTHS NOT TO EXCEED THE NEC REQUIREMENTS AND OF THE SAME SIZE AS THE MOTOR FEEDER CONDUIT. FLEXIBLE CONNECTIONS BETWEEN RECESSED LIGHTING FIXTURES, EXHAUST FANS, AND JUNCTION BOXES SHALL BE MADE WITH SINGLE STRIP (GREENFIELD) APPROVED EQUAL FLEXIBLE STEEL CONDUIT. WIRING �r,(�■�II�IIR�PEyt���il��i�tl:���l��_P►�1���/_\��_�1�L�7�Ey:/_1��:3�/_�y�il��i��i��� • LIGHTING AND POWER CIRCUITS . . . . . . . . . . . . . . . N0. 12 AWG • SIGNAL CIRCUITS WITH COMMON OR INDIVIDUAL LEADS ... N0. 14 AWG • REMOTE CONTROL LEADS . . . . . . . . . . . . . . . . . . N0. 14 AWG • FIXTURES . . . . . . . . . . . . . . . . . . . . . . . . . . N0. 14 AWG MIN AND AS REQ. BY UL AL� INSULATED �IGHTING AND POWER SECONDARY CONDUCTORS SHAL� BE COPPER, FIRST QUALITY, NEW AND SOUND, WITH 600 VOLT TYPE THHN INSULATION, 75*C MOISTURE AND HEAT RESISTANT TYPE THW, ASTM B-3 AND B-8. THE CONDUIT SYSTEM SHALL BE FREE OF ALL BURRS, SHARP EDGES AND DEFECTS BEFORE WIRE IS PULLED. COMMUNICATION, SOUND AND OTHER �OW-VOLTAGE WIRING SHAL� BE OF SIZE AND INSULATION RECOMMENDED BY THE MANUFACTURER OF THE EQUIPMENT BEING SERVED. THE CONTRACTOR SHALL REFER TO THE GENERA�, HEATING-VENTI�,4TING AND PLUMBING SPECIFICATIONS AND INCORPORATE ALL ELECTRICAL WORK REQUIRED BY THESE CONTRACTS INTO THIS CONTRACT. THE CONTRACTOR SHALL PROVIDE FOR ROUGH-IN FOR ALL FIXTURES AND DEVICES AND AFTER SET BY OTHER CONTRACTORS; SHALL WIRE THROUGH THE EQUIPMENT TO THE DEVICES FURNISHED AND INSTALLED WITH THE EQUIPMENT. WIRE ACCORDING TO MANUFACTURER'S SHOP DRAWINGS AS FURNISHED WITH THE RESPECTIVE EQUIPMENT. ALL ELECTRICAL POWER TO EQUIPMENT FURNISHED UNDER OTHER CONTRACTS SHALL BE INSTA��ED AND WIRED COMPLETELY BY THIS CONTRACTOR UN�ESS OTHERWISE NOTED. �sH uNE THE CONTRACTOR SHALL INSTALL, IN EACH EMPTY CONDUIT, ONE NYLON FISH LINE MARKED ON EACH END FOR THE FUTURE INSTALLATION OF WIRE AND CABLE. SPLICES - SECONDARY A�L SPLICING SHA�� BE DONE IN OUTLET BOXES, JUNCTION BOXES AND NOT IN THE CONDUIT. SPLICES MAY BE MADE WITH SOLDERLESS CONNECTORS, PRESSURE CONNECTORS, BUGS AND THEN INSULATED WITH TAPE. THE CONTRACTOR SHALL USE SCOTCH ELECTRICAL TAPE N0. 22 OR 33, SCOTCHLOK SPRING CONNECTORS WITH VINYL COVER, SCOTCH CAST RESIN N0. 4 AND SPLICING KIT OR PRESSURE SPLICE KIT, ALL AS APPROVED EQUAL AS RECOMMENDED BY THE MANUFACTURER OF THE SPLICING MATERIALS AND TNE WIRE MANUFACTURER. CONNECTORS WHICH LEAVE CUT ENDS OF WIRE EXPOSED TO FLEXIBLE OR SO�f CONNECTOR INSULATOR WIL� NOT BE PERMITfED. PROPER SIZE CONDUCTORS SHAL� BE USED AT ALL SP�ICE �OCATIONS. SOLDERED CONNECTIONS INSU�ATED WITH E�ECTRICAL PLASTIC TAPE WIL� BE PERMITTED. PROVIDE PULL BOXES AS REQUIRED. BOXES SHALL BE SUPPORTED INDEPENDENTLY OF CONDUITS ENTERING THEM WITH RODS, HANGERS, BRACKETS OR OTHERWISE SUITABLE MEANS. RACEWAY ACCESS ALL OUTLET BOXES SHALL BE OF GALVANIZED STEEL, AT LEAST 1" DEEP AND CAREFULLY SIZED AS TO THE NUMBER OF CONDUCTORS AND DEVICES AND ACCORDING TO APPROPRIATE SECTIONS OF THE NEC. BOXES SHAL� HAVE KNOCK-OUTS FOR CONDUIT TERMINATIONS AND MOUNTING LUGS AND EARS FOR COVERS. OUTLET BOXES FOR WIRING DEVICES IN FINISHED WALLS SHALL BE ONE PIECE STANDARD GANG TYPE OF SIZE TO ACCOMMODATE NUMBER OF DEVICES NOTED. BOXES SHALL HAVE PLASTIC COVERS TO BRING BOX OPENING FLUSH WITH FINISHED WALL. FLASHING ALL FLASHING OF CONDUITS EXTENDING THROUGH ROOF AND OTHER LOCATIONS SHAL� BE FURNISHED AND INSTALLED BY THE ELECTRICA� CONTRACTOR. swrrcHEs ALL SWITCHES MOUNTED VERTICALLY SHALL HAVE THE "ON" POSITION AT THE TOP AND ALL HORIZONTAL MOUNTED SWITCHES SHALL HAVE THE "ON" POSITION AT THE LEFT. TUMB�ER SWITCHES SHALL BE THE A.C. HEAVY DUTY, 120/277 VOLTS, FLUSN TOGGLE TYPE SWITCH RATED AT 20 AMPERES AND U.L. APPROVED. CONVENIENCE OUTLEfS DUPLEX RECEPTACLES IN ALL AREAS EXCEPT IN WP LOCATIONS AND SPECIFIED OTHERWISE, SHALL BE OF THE GROUNDED, 3-WIRE NEMA TYPE RATED AT 20 AMPERES AT 125 VOLTS. FURNISH WITH 0.032" STAINLESS STEEL COVERPLATE. RECEPTACLES TO BE IVORY FINISH. GFCI RECEPTACLES SHALL BE END OF LINE TYPE, SOLID STATE WITH TEST AND RESET BU�ifON, IL�UMINATED INDICTOR, RATED 125 VOLTS, 20 AMPERES AND SHALL CONTINUOUSLY MONITOR CURRENT IN THE PHASE AND NEUTRAL CONDUCTORS AND SHALL INTERRUPT THE CIRCUIT FOR A CURRENT DIFFERENTIAL OF MORE THAN 5MA TO THE OUTLET. WALL PLATES UNLESS OTHERWISE SPECIFIED, SWITCH, RECEPTACLES, PUSH BUTTONS, BLANK TELEPHONE AND OTHER OUTLET PLATES SHALL BE BRUSHED OR SATIN STAIN�ESS STEEL WITH BEVELED EDGES SO AS TO LAY FLAT AGAINST THE WAL�. WHERE MORE THAN 1 SWITCH OCCURS AT ONE POINT, GANG PLATES SHAL� BE USED. ALL PLATES SHALL BE SET TRUE AND PLUMB AND SHA�L FIT TIGHT AGAINST FINISHED WALL SURFACES AND OUTLET BOXES. �OCATION OF OUTLETS UN�ESS OTHERWISE INDICATED • WALL SWITCH OUTLETS . . . . . . . . . . . . . 4'-0" A.F.F. • CONVENIENCE OUT�ETS . . . . . . . . . . . . .1'-6" A.F.F. • ABOVE COUNTER OUTLETS . . . . . . . . . . . 4" TO CENTER ABOVE COUNTER OR BACKSPLASH • DESK TELEPHONE OUTLETS . . . . . . . . . . . 1'-6" A.F.F. • WALL TELEPHONE OUTLETS . . . . . . . . . . 4'-6" A.F.F. • PLUG-IN STRIP . . . . . . . . . . . . . . . . . TO BE DETERMINED AT SITE • EXTERIOR & INTERIOR WAL� BRACKETS. .... TO BE DETERMINED AT SITE TELEPHONE, DATA AND SECURtTY SYSTEMS PRIOR TO INSTALLATION OF CONDUIT AND BOXES, THE CONTRACTOR SHALL CONTACT THE OWNER AND FORMALLY REQUEST DETAILEd INSTRUCTIONS OF THEIR REQUIREMENTS. THE CONTRACTOR SHALL COMPLY WITH ALL INSTRUCTIONS OF THE TELEPHONE COMPANY AS THE SYSTEM MUST BE INSTAL�ED TO SUIT THE CURRENT AND FUTURE REQUIREMENTS OF THE OWNER. THE CONTRACTOR SHAL� FURNISH AND INSTALL CONDUIT, BOXES AND PULL STRING FOR THE TELEPHONE, DATA AND SECURITY SYSTEMS AS INDICATED. EACH OUTLET SHALL CONSIST OF 2" X 4" X 2-1/8 " BOX WITH PLASTIC RING AND COVERPLATE AS SPECIFIED AND 3/4" CONDUIT TO ACCESSIBLE CEILING AREA. MOTOR CONNECTIONS EACH CONTRACTOR WILL PROVIDE NECESSARY STARTERS AS REQUIRED FOR OPERATION OF THE MOTORS PROVIDED UNDER THEIR CONTRACT. THE ELECTRICAL CONTRACTOR SHALL SET THE STARTER AND LINE VOLTAGE CONTROLS AND MAKE ALL FINAL CONNECTIONS. THIS ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER DIRECTION OF ROTATION OF ALL MOTORS AND SHALL CHANGE CONNECTIONS AS REQUIRED TO PROVIDE FOR PROPER ROTATION. LIGHTING FlXTURES FIXTURE NUMBERS, AS SPECIFIED, HAVE BEEN TAKEN FROM THE CATALOGS OF FIXTURE MANUFACTURERS. FIXTURE NUMBERS AND DESCRIPTIONS ARE INTENDED TO DENOTE A STANDARD OF QUALITY AND TYPE. INSTALLATION FIXTURES USED FOR LAY-IN GRID SHALL HAVE ADDITIONAL SUPPORT AS REQUIRED AND SHALL HAVE ALL CLIPS INSTALLED TO INSURE RIGID INSTALLATION. EACH FIXTURE SHALL BE ADJUSTED TO ACCOMPLISH A SYMMETRICAL PLACEMENT IN THE CEILING SPACE AND EASY REMOVAL OF TNE LENS. RECESSED FIXTURE NOUSINGS SHA�L BE FREELY SUPPORTED THROUGH THE USE OF CHANNELS AND ADJUSTED TO PUT FRAME FLUSH WITH FINISHED CEILING. LIGHT �EAKS WILL NOT BE TOLERATED AND GASKETS SHA�L BE USED TO PREVENT THEM. A�L �ENSES SHALL HAVE A MINIMUM TOLERANCE AND SHALL FIT SNUG IN THEIR FRAMES. FIXTURES SHALL BE DESIGNED, ARRANGED, FURNISHED AND INSTALLED COMPLETE WITH ALL ACCESSORIES FOR MOUNTING TO THE CEILING CONSTRUCTION FOR WHICH IT IS TO BE INSTALLED. THE CONTRACTOR SHALL CHECK CAREFULLY WITN FINAL CEIUNG FINISH SCHEDULE OF ROOMS BEFORE ORDERING FIXTURES. THE CONTRACTOR SHAL� BE HELD RESPONSIBLE FOR THE INSTALLATION COMPLETE IN EVERY DETAIL. EXISTING ELECTRICAL DISTRIBUTION MODIFICATIONS FOR DISTRIBUTION EQUIPMENT MODIFICATIONS TO EXISTING MAIN SWITCHBOARDS OR PANELBOARDS, NEW SWITCHES AND CIRCUIT BREAKERS TO BE INSTALLED SHALL BE OF THE SAME MANUFACTURER, STYLE AND TYPE AS THE EXISTING EQUIPMENT, WITH RATINGS AS SHOWN. FURNISH AND INSTALL ORIGINAL MANUFACTURER MOUNTING AND INSTAL�ATION HARDWARE, CLOSURE PLATES, AND TRIM PIECES AS REQUIRED TO COMPLETE THE INSTALLATION. FIELD FABRICATED HARDWARE SHALL NOT BE ACCEPTABLE. ALL EXISTING DISTRIBUTION EQUIPMENT BEING MODIFIED SHALL BE RETURNED TO ORIGINAL, FULLY ENCLOSED CONDITION. FAULT CURRENT AND SERIES RATING MUST BE MAINTAINED WITH MODIFICATIONS. BEFORE ADDING A NEW FEEDER TO THE EXISTING BUILDING ELECTRICAL SERVICE, THE CONTRACTOR SHAL� CHECK THE RELATED EXISTING SERVICE OR DISTRIBUTION PANEL CAPACITY PER NEC 220.87, DO NOT MAKE ANY CONNECTION THAT WOULD OVER�OAD ANY CIRCUIT OR IMPROPERLY USE ANY EXISTING CIRCUIT. THE CONTRACTOR SHALL PERFORM A FIELD SURVEY OF ANY SUCH INADEQUATE CONDITION, AND PROVIDE INFORMATION TO THE ENGINEER IN DETAIL AND IN A TIMELY MANNER SO THAT NECESSARY REDESIGN MAY BE ACCOMPLISHED BY THE ENGINEER. ELECTRIC PANELS THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL PANELS AS SHOWN ON PLANS OR SPECIFIED. CIRCUITING SHOWN IS TENTATIVE AND MAY BE RE-ARRANGED FOR PURPOSE OF LOAD BALANCE, ETC. PANELS SHALL CONTAIN A FULL COMPLEMENT OF BREAKERS OF SIZES AND TYPE INDICATED ON PANEL SCHEDULES. CONTRACTOR SHALL VERIFY PANEL SPACE FOR FLUSH OR SURFACE MOUNTING. CABINETS SHALL BE CODE GAUGE STEEL WITH TRIM AND DOOR, LOCK AND KEYS AND DIRECTORY CARD HOLDER IN DOOR. TYPEWRITfEN PANEL DIRECTORY CARD SHAL� BE LE�f IN DOOR AT END OF JOB. PROVIDE FOUR LOCKING DEVICES PER PANEL TO BE USED AT OWNER'S DISCRETION. 120/208V PANELBOARDS, UNLESS OTHERWISE NOTED, SHALL BE SQUARE-D TYPE NQOD 120/208 VOLTS, 3 PHASE, 4 WIRE, S/N WITH MAIN BREAKER OR LUGS ONLY IN THE MAINS AS NOTED WITH SING�E POLE, INDIVIDUA� TRIP AND 2 AND/OR 3 PO�E COMMON TRIP BOLT-ON TYPE BRANCH CIRCUIT BREAKERS AND AS PER DRAWINGS AND PANEL SCHEDULES. EXTEND TWO EMPTY 1" CONDUITS FROM PANEL TO SPACE ABOVE DROPPED CORRIDOR CEILING FOR FUTURE USE. DISCONNECT SWITCHES FUSED AND NON-FUSED DISCONNECT SWITCHES SHA�L BE FURNISHED AT �OCATIONS SHOWN ON PLAN OR FOR EQUIPMENT MOUNTED IN REMOTE AREAS AS REQUIRED BY CODE. SWITCHES SHALL BE OF THE POLES INDICATED OR REQUIRED, 600 VOLT, IN NEMA ENCLOSURE FOR INDOOR OR NEMA 3R ENCLOSURE FOR EXTERIOR USE. SWITCHES SHALL BE EQUAL TO SQUARE-D HEAVY-DUTY TYPE. FURNISH COMPLETE SET OF FUSES FOR FUSED DISCONNECT. WHERE MOTOR FEEDS EXCEED 50' OR ARE LOCATED OUTSIDE AREA THAT PROTECTIVE DEVICES ARE LOCATED, THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL NON-FUSED DISCONNECT SWITCHES. LABELING PANELS, SWITCHES, ETC. AL� ELECTRIC PANELS AND PULL BOXES FOR SOUND, TV, AND TELEPNONE SHA�� BE �ABELED INSIDE OF THEIR COVERS AS THEIR USE AND FUNCTION. LABELING SHALL BE DONE BY STENCIUNG IN BLACK PRINT OR OTHER SUITAB�E MEMO ACCEPTABLE TO THE ARCHITECT. ALL DISCONNECT SWITCHES SHALL BE LABELED WITH VINYL ADHESIVE LETTERING AS TO ITS FUNCTION. ALL SWITCHES AND DEVICES LOCATED REMOTELY FROM THE EQUIPMENT IT SERVES SHALL BE SO LABELED AS TO IDENTIFICATION AND USE. ALL DEVICES THAT ARE NORMAL�Y SUPPLIED WITH DIRECTORIES SHA�L BE FILLED IN COMPLETELY WITH TYPED �ETfERING. PROJECT COMPLETION AT THE COMPLETION OF THE WORK, ALL PARTS OF THE ELECTRICAL SYSTEM SHALL BE TESTED FOR GROUNDS AND OTHER DEFECTS AND ALL PARTS SHALL BE PROPERLY ADJUSTED AND LE�1" IN PROPER OPERATING CONDITION. AL� OVER�OAD DEVICES INCLUDING THE OVERLOAD TRIP COILS OF THE STARTERS AND AUXI�IARIES SHAL� BE ADJUSTED FOR THE �OAD CONTROL�ED AND NOT THE MOTOR SIZE. GUARANTEE THE CONTRACTOR SHALL GUARANTEE ALL MATERIAL, EQUIPMENT AND WORKMANSNIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE ARCNITECT AND OWNER. HE SHA�� REPLACE AL� DEFECTIVE MATERIA� AND WORKMANSHIP FURNISHED AND INSTAL�ED BY HIM AND ALL OTHER WORK AND EQUIPMENT DAMAGED THEREBY WITHOUT COST TO THE OWNER. IN ADDITION TO THE ONE YEAR GUARANTEE, THE CONTRACTOR SHALL FURNISH ANY WARRANTIES OR GUARANTEES THAT NORMALLY COME WITH SPECIFIC PIECES OF EQUIPMENT THAT EXCEEDS THE ONE YEAR GUARANTEE. THESE ADDITIONAL WARRANTIES SHALL BE GIVEN TO THE OWNER FOR THE TIME PERIOD SPECIFIED. AS-BUILT DRAWINGS THE CONTRACTOR SHA�� PROVIDE COMPLETE AS BUILT DRAWINGS AT THE END OF THE PROJECT. DRAWINGS TO SHOW EXACT LOCATIONS OF ALL DEVICES AND EQUIPMENT ALONG WITH ALL PERTINENT CONCEALED CONDUIT RUNS. END OF ELECTRICAL SPECIFICATIONS SpENCER BRISTOI. ENGINEERING, INC. 5655 PFncl�lrzFF PARkway, SuirF 100 Norzca�ss, GeoaGin 3009`Z TeL 770.414.1628 Fnx 770.414.6024 SBE PaojEcr No. 15048 NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made onty by the Architect. MECHANICAL LEGEND SYMBO�S 24x12 RECTANGULAR DUCT SIZE: FIRST DIMENSION IS SIDE DRAWN ----- ROUND DUCTWORK OR FLUE PIPING �-��____�- RECTANGULAR TO ROUND DUCT TRANSITION FLEXIBLE ROUND DUCT �� FLEXIB�E DUCT CONNECTION SQUARE DUCT ELBOW WITH TURNING VANES �� �t� MVD MANUAL VOLUME DAMPER EQUIPMENT ON ROOF ABOVE T -� WALL MOUNTED THERMOSTAT OR TEMPERATURE SENSOR (� CUBIC FEET PER MINUTE AIRFLOW ABBREVIATIONS APPROX APPROXIMATE BAS BUILDING AUTOMATION SYSTEM COND CONDENSER CFM CUBIC FEET PER MINUTE DIA DIAMETER db DRY BULB DX DIRECT EXPANSION EER ENERGY EFFICIENCY RATING ERT ENTERING AIR TEMPERATURE Edb ENTERING DRY BULB ESP EXTERNAL STATIC PRESSURE EVAP EVAPORATOR Ewb ENTERING WET BULB FPM FEET PER MINUTE Ff FEET H HEIGNT HP HORSE POWER IN INCHES IN. WG INCHES WATER GAUGE kW KILOWAI-fS LAT LEAVING AIR TEMPERATURE Ldb LEAVING DRY BULB Lwb LEAVING WET BU�B MAX MAXIMUM MBH THOUSAND BTU PER HOUR MIN MINIMUM OA OUTDOOR AIR PD PRESSURE DROP PSIG POUNDS PER SQUARE INCH GAUGE RPM REVOLUTIONS PER MINUTE SEER SEASONAL ENERGY EFFICIENCY RATING SQ. FT. SQUARE FEET TEMP TEMPERATURE TYP TYPICAL W WIDTH wb WET BULB 'F DEGREES FAHRENHEIT � t TEMPERATURE DIFFERENCE GRILLE SCHEDULE MARK TITUS NECK MODULE FINISH NOTES MODEL No. SIZE SIZE DA TDC 9x9 24x24 WHITE 1:3:4:5:6: OB 50F 12x8 24x12 WHITE 2:3:4:5: OC 50F 12x12 24x24 WHITE 2:3:4:5: 1. SQUARE 24"x24" ALUMINUM LOUVER FACE CEILING SUPPLY DIFFUSER 2. 1/2"x1/2"x1/2" A�UMINUM EGG-CRATE CEILING DUCTED RETURN GRIL�E 3. PROVIDE LAY-IN FRAME TYPE 4. PROVIDE STEEL OPPOSED BLADE BALANCING DAMPER 5. SQUARE NECK 6. PROVIDE SQUARE TO ROUND TRANSITION ROOFTOP AIR COND ITIONING UNIT SCHED ULE � • �• •• RTU-1 I 50XL-A30 TOTA� SENSIBLE COOLING COOLING MBH MBH 28.6 20.0 TOTA� MIN APPROX. SUPPLY SUPPLY OA ESP FAN CFM CFM IN WG HP 1�1 �1 ! Ii ELEC HEAT kW/STAGES 7.5/2 NOTES 1:2:3:4:5:6:7:8:9:1 0:11:1 2:1 3:1 4: 1. COOLING CAPACITIES BASED ON AIR ENTERING EVAPORATOR AT 80'Fdb, 67'Fwb AND 95'F AMBIENT AIR TEMPERATURE. 2. HEATING CAPACITY BASED ON REVERSE CYC�E HEAT PUMP OPERATION AT 47°F AMBIENT AIR TEMPERATURE. 3. UNIT SHALL BE VERTICAL AIRFLOW, END REfURN AS MANUFACTURED BY CARRIER, TRANE, OR APPROVED MANUFACTURER. 4. PROVIDE WITH HINGED ACCESS PANELS, SIDE ACCESS FILTER RACK WITH FILTER, CURB, MANUAL OSD DAMPER, LOW AMBIENT KIT AND E�ECTRICAL HEAT. 5. PROVIDE WITH CONDENSER HAIL GUARDS. 6. ROUTE CONDENSATE TO APPROVED LOCATION. 7. PROVIDE FOR THROUGH-CURB ELECTRICAL WIRING. 8. PROVIDE 120V ELECTRICAL CONVENIENCE OUTLET. 9. PROVIDE FACTORY INSTALLED DISCONNECT OR CIRCUIT BREAKER. 10. PROVIDE ROOF CURB - CPRFCU011A00 CARRIER. COORDINATE INSTALLATION OF CURB WITH MARKET AND MARKETS ROOFING CONTRACTOR. INSTA�L CURB AND REQUIRED ACCESSORIES TO MAINTAIN ROOF WARRANTY. 11. PROVIDE FUSED ELECTRIC HEAT PACKAGE (CPHEATER085A00), DISCONNECTS AND INDOOR 7 DAY PROGRAMMABLE THERMOSTAT. 12. COORDINATE REQUIREMENTS FOR MOTOR CONTROLLERS/STARTERS WITH ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL FURNISH ALL MOTOR CONTROLLERS/STARTERS. 13. PROVIDE FUSED ELECTRIC HEAT PACKAGE (CPHEATER085A00), DISCONNECTS AND INDOOR 7 DAY PROGRAMMABLE THERMOSTAT. 14. PROVIDE ENERGY STAR RATED 15 SEER WITH PURON R-410A REFRIGERANT. GENERAL NOTES 1. SPACE ABOVE CEILING WILL BE CRITICAL COORDINATE DUCTWORK AND PIPING WITH UTILITIES AND OTHER TRADES. FIELD VERIFY FOR CLEARANCE BEFORE INSTALLATION. Fa COORDINATE FINAL LOCATIONS OF DIFFUSERS AND GRILLES WITH LIGHTING PLAN. PROVIDE ALL NEW DUCTWORK, DIFFUSERS, AND GRILLES FOR SUPPLY AND RETURN AIR. 4. ALL POWER WIRING BY ELECTRICAL CONTRACTOR. 5. ALL CONTROL WIRING BY HEATING CONTRACTOR. 6. DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO FIELD VERIFY ALL DUCT ROUTING. ADDITIONAL OFFSETS TO BE EXPECTED. 7. MECHANICAL CONTRACTOR TO VERIFY ALL POWER REQUIREMENTS OF EXISTING AND NEW EQUIPMENT WITH THE ELECTRICAL CONTRACTOR. 8. ALL DUCT RUNOUTS TO DIFFUSERS TO BE INSTALLED WITH MANUAL DAMPERS WITH LOCKING QUADRANTS. MAXIMUM �ENGTH OF FLEXIBLE DUCT = 5'-0". 9. THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL MISCELLANEOUS SUPPORTING STEEL FOR EACH ITEM OF MECHANICAL EQUIPMENT. 10. THE CONTRACTOR SHALL EXECUTE THE WORK IN STRICT ACCORDANCE WITH THE SPECIFICATIONS AND DRAWINGS. WHERE WORK IS SHOWN ON THE DRAWING AND NOT SPECIFIED OR SPECIFIED AND NOT SHOWN ON THE DRAWING, THE CONTRACTOR SHALL PROVIDE ALL SUCH WORK. 11. IN THE EVENT OF A CONFLICT BETWEEN THE SPECIFICATIONS AND DRAWINGS, THE MORE STRINGENT CONDITION SHALL APPLY. 12. MAINTAIN PROPER CLEARANCES AS RECOMMENDED BY THE EQUIPMENT MANUFACTURER AND ALL INDUSTRY STANDARDS. 13. PROVIDE DOUBLE THICKNESS TURNING VANES ON ALL SQUARE HEELED ELBOWS. 14. ALL JOINTS, SEAMS, AND CONNECTIONS FOR DUCTS TO BE IN ACCORDANCE WITH SMACNA REQUIREMENTS. TAPES AND MASTICS USED TO SEAL DUCTS SHAL� BE IN ACCORDANCE WITH UL 18A. TAPES AND MASTICS USED TO SEAL FLEXIBLE DUCTS AND A►R CONNECTORS SHALL COMPLY WITH UL 181 B. A�� DUCTWORK DESIGN, CONSTRUCTION, AND INSTALLATION SHALL CONFORM TO OHIO MECHANICA� CODE SECTION 603. 15. MECHANICAL CONTRACTOR TO PERFORM AIR BALANCING OF SYSTEM UPON COMPLETION OF INSTALLATION. AIR BALANCING REPORT SHA�L CONFORM WITH AABC OR NEBC STANDARDS. VENTILATION SYSTEM SHALL BE BALANCED TO 100 CFM TO MEET THE INDIANA MECHANICAL CODE. 16. SPRINKLER SYSTEM IS EXISTING. EXTEND OR RELOCATE SPRINKLER PIPING TO NEW CEI�ING ELEVATIONS. CONTRACTOR TO PROVIDE HEADS TO MATCH MAIN STORE AND APPROPRIATE FOR CEILING TYPE. COORDINATE FINAL HEAD LOCATIONS WITH DUCTWORK AND LIGHTING. 17. FIRE PROTECTION CONTRACTOR TO PREPARE SPRINKLER SHOP DRAWINGS FOR REVIEW. FIRE PROTECTION CONTRACTOR TO SUBMIT DRAWINGS TO THE PLAN REVIEWER PRIOR TO COMMENCING WORK ON SPRINKLER SYSTEM. 18. THE BUILDING STRUCTURE SHA�� NOT BE WEAKENED BY THE INSTALLATION OF MECHANICAL SYSTEMS PER INDIANA MECHANICAL CODE. 19. CONDENSATE DRAIN SYSTEM SHAL� TERMINATE AS REQUIRED BY INDIANA MECHANICAL CODE. NOTES TO CONTRACTOR: 1. CONTRACTOR SHALL VISIT THE SITE BEFORE WORK IS STARTED, AND SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO INSTALLATION. 2. CONTRACTOR SHALL FIELD VERIFY LOCATION OF RTU-1 WITH EXISTING CONDITIONS. ASSURE UNIT IS AT �EAST 10' AWAY FROM EDGE OF THE BUILDING AND THE OUTSIDE AIR INTAKE IS AT LEAST 10' AWAY FROM ANY BUILDING EXHAUST AND PLUMBING VENTS. ELECTRIC RADIANT CEILING PANEL HEATER SCHEDULE MARKEL HEAT MARK MODEL No. OUTPUT WATTS SIZE NOTES BTUH RCH-1 CP803 1280 375 2x2 1:2:3:4:5:6:7: RCH-2 CP803 1280 375 2x2 1:2:3:4:5:6:7: 1. 2'x2� ELECTRIC RADIANT CEILING PANEL HEATER 2. PROVIDE T-BAR MOUNT FOR LAY-IN CEILING 3. 1" THICK NOMINAL HEIGHT 4. 2" THICK INSULATION ON BACK OF PANEL 5. PROVIDE TIME DELAY THERMOSTAT, MAXIMUM OF 2-HOURS OF ENERGIZED 6. PROVIDE DISCONNECT SWITCH 7. PROVIDE A WA�� MOUNTED THERMOSTAT RCf I.��L' RCf FLOOR 1 /4" = 1'-( PLAN - MECHANICAL � � � _�,���'� � �..... KEY PLAN 2 �/s4» _ �'-o~ SpENCER BRISTO� ENC�INEERING, INC. 5655 PFncl�7rzEE PArekwny, SuirE 100 NoacRoss, GEoaciA 3009`L TEL 770.h14.1628 Fnx 770.414.602h Sk3F f'ieojECT No. 15048 NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made only by the Architect. GENERAL: A. THE GENERAL CONDITIONS OF THE GENERAL SPECIFICATIONS, ALONG WITH ALL APPLICABLE INSTRUCTIONS TO BIDDERS SHALL FORM A PART OF THIS SECTION OF THE SPECIFICATIONS. B. REFERENCE IS MADE TO REQUISITES FOR BIDDERS AND CONTRACTORS UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, WHICH SHALL BE CONSIDERED BINDING, UNLESS OTHERWISE NOTED UNDER THIS SECTION. ► •� EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE CONSTRUCTION DETAI�S, BOTH AS ON TENANT CONSTRUCTION DRAWINGS AND LANDLORD'S AS REFERRED T0, BEFORE SUBMITTING HIS BID AS NO ALLOWANCES WILL BE MADE BECAUSE OF THE CONTRACTOR'S UNFAMILIARITY WITH THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY THE PACE OF THE GENERAL CONSTRUCTION. 1►�9»[��[�Pt�l�•����1 ALL PROPOSALS SHALL PRECLUDE THAT CONTRACTOR IS FAMILIAR WITH JOBSITE CONDITIONS AND UTILITY LOCATIONS AND THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. '»i.��l��� AL� PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR INVOLVED. CODE REQUIREMENTS: A�L WORK UNDER THIS CONTRACT SHA�L COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS OR AS DIRECTED BY THE OWNER, AND SHALL SATISFY A�� APPLICABLE CODES, ORDINANCES, OR REGULATIONS OF THE GOVERNING BODIES, WHETHER SO SHOWN OR NOT, AND ALL MODIFICATIONS REQUIRED BY SUCH AUTHORITIES SHALL BE MADE BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO THE OWNER. MATERIALS AND WORKMANSHIP: A. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY THE MANUFACTURERS, AND UNLESS OTHERWISE SPECIFIED SHALL BE NEW, AND FREE FROM ANY DEFECTS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COMPETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE MANNER. WORK SHALL BE PROPERLY PROTECTED DURING CONSTRUCTION, AND ON COMPLETION, THE INSTALLATION SHALL BE THOROUGHLY CLEANED AND ALL DEBRIS PRESENT AS A RESULT OF THIS CONTRACT SHALL BE REMOVED CODES AND REGULATIONS: EACH SUBCONTRACTOR SHALL COMPLY WITH A�L LAWS, ORDINANCES, RULES AND REGUlATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN OR SPECIFICATIONS ARE AT A VARIANCE, HE SHALL PROMPTLY NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS, ORDINANCES, RULES AND REGULATIONS AND WITHOUT GIVING SUCH NOTICE, THE SUBCONTRACTOR SHAL� BEAR ALL COSTS ARISING THEREFROM. PROTECTION OF WORK AND PROPERTY: A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL HIS WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS WORK. HE SHALL MAKE GOOD ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND NOT TO HIS FAULT OR NEGLIGENCE. HE SHALL ADEQUATELY PROTECT ADJACENT PROPERTY AS WELL. B. EACH SUBCONTRACTOR SHA�L TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFE(Y OF THEIR EMPLOYEES ON THE WORK AND SHALL COMPLY W►TH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY TO A PERSON ON OR RDJACENT TO THE PREMISES WHERE THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN AL� INSURANCE REQUIRED TO PROTECT HIMSE�F, OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST PROPERTY DAMAGE AND PUBLIC LIABILITY. CHANGES IN THE WORK: THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEWG ADJUSTED ACCORDINGLY. COOPERATION: ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE ADEQUATE TIME AT THE PROPER STAGE OF CONSTRUCTION TO FULFILL HIS CONTRACTS. REFERENCE SHALL BE MADE TO THE OWNER FOR INSTRUCTIONS SNOU�D ANY QUESTIONS ARISE BETWEEN TRADES AS TO THE PLACING OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR SHOULD IT APPEAR DESIRABLE TO REMOVE ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE OF STRENGTH OF THE STRUCTURE. SUBSTITUTION OF MATERIALS: MANUFACTURER'S NAMES ARE �ISTED HEREIN TO ESTABLISH A STANDARD. THE PRODUCTS OF OTHER MANUFACTURERS WIL� BE ACCEPTABLE, IF IN THE OPINION OF THE TENANT, TNE SUBSTITUTE MATERIAL IS OF A QUALITY AS GOOD OR BETTER THAN THE MATERIAL SPECIFIED, AND WILL SERVE WITH EQUAL EFFICIENCY AND DEPENDABILITY, THE PURPOSE FQR WHICH THE ITEMS SPECIFIED WERE INTENDED. SHOP DRAWINGS: SHOP DRAWINGS AND CATALOGUE DATA ON ALL MAJOR ITEMS OF EQUIPMENT AND SYSTEMS, AND SUCH OTHER I�LUSTRATIVE MATERIAL AS MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THIS CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND CHANGES DURING CONSTRUCTION. DRAWINGS AND SPECIFICATIONS: A. THE DRAWWGS SHOW DIAGRAMMATICAL�Y THE �OCATIONS OF THE VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. B. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE CONTRACTOR IN ITEMS SHOWN ON CONTRACT DRAWINGS, THE SHQP DRAWINGS, DESCRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. RESPONSIBILITY: A. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS CONTRACT. HE SHALL PRODUCE COMPLETE FINISHED OPERATING SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS WORK, REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR INDICATED. B. CONTRACTOR SHALL SUPPLY TO LANDLORD AND TENANT A CERTIFIED BALANCE REPORT AT COMPLETION OF PROJECT. THIS IS REQUIRED FOR BOTH REMODELED AND NEW STORES. HEATING, VENTILATING AND AIR CONDITIONING GENERAL: A. THE WORK COVERED BY THIS SECTION OF THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE RESPECTIVE DRAWINGS, INFORMATION, OR INSTRUCTIONS TO BIDDERS, AND THE GENERAL CONDITIONS, ADDENDA, OR DIRECTIVES WHICH MAY BE ISSUED BY THE OWNER, HEREWITH, OR OTHERWISE, SHAL� BE COMPLIED WITH IN EVERY RESPECT. B. THE �ISTING HEREIN OF AN ARTICLE OR MATERIAL, OPERATION OR METHOD, REQUIRES THAT THE CONTRACTOR SHALL FURNISH AND INSTALL EACH ITEM LISTED, UNLESS SPECIFICALLY NOTED TO THE CONTRARY. THE CONTRACTOR SHALL PERFORM EACH OPERATION PRESCRIBED OR LISTED ACCORDING TO THE CONDITIONS STATED. EXAMINATION OF SITE: A�L CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL CONDITIONS THEREON AND/OR THEREIN. ALL PROPOSA�S SHA�L TAKE INTO CONSIDERATION AL� SUCH CONDITIONS AS MAY AFFECT THE WORK UNDER THIS CONTRACT. SCOPE: FURNISH ALL MATERIALS, EQUIPMENT, AND LABOR NECESSARY FOR A COMPLETE FULLY OPERATIVE HEATING, VENTILATING, AND AIR CONDITIONING SYSTEM EXCEPT AS SPECIFICA�LY EXCLUDED BY THE DRAWINGS, AND/OR TENANT'S DIRECTIONS. EQUIPMENT: A. ROOFTOP UNIT: 1. 2. 3. 4. 5. 6. UNITS SHALL BE FACTORY ASSEMBLED AND PRE—TESTED, AND WILL INCLUdE HEAVY GALVANIZED STEEL HOUSING FINISHED WITH BAKED ENAMEL, AIR COOLED CONDENSERS WITH COPPER TUBES AND ALUMINUM FINS, CONTROL PANEL, COMPRESSOR HIGH AND LOW PRESSURE CUTOUTS, MUFF�ERS, CRANKCASE HEATERS, LIQUID RECEIVE, ETC. COMPRESSORS SHALL BE OF THE HERMETICALLY SEALED OR SEMI—HERMEfICALLY SEA�ED TYPE. (LOW AMBIENT CONTROL STD.) FAN SHALL BE A �OW TO MEDIUM PRESSURE SINGLE ZONE DRAW—THRU UNIT EQUAL TO TRANE OR CARRIER. THE UNIT SHALL BE COMPLETE WITH COOLING AND/OR HEATING COILS AND ACCESSORIES AS SPECIFIED BUILT—IN MAGNETIC CONTACTORS, AIR FLOW SWITCH, AND FACTORY PREWIRED TO TERMINAL STRIPS FOR LINE AND CONTROL CONNECTIONS IN THE FIELD. A THERMAL CUTOUT SHALL BE FURNISHED WITH EACH STRIP HEATER TO PROTECT THE HEATER AGAINST AIR FAILURE. THE COMPLEfE HEATING UNIT SHALL BE LISTED BY UNDERWRITER'S LABORATORIES, INC. COILS SHALL BE ARRANGED FOR MINIMUM TWO STAGE CONTROL 1QKW AND ABOVE. FI�TERS SHA�� BE OF THE THROW AWAY TYPE WHEREVER POSSIBLE. IF FILTERS ARE OF THE PERMANENT IYPE, THEN THEY MUST BE OF THE CLEANABLE, HIGH VE�OCITY TYPE AND SHALL BE AMERICAN FILTERS, AIR MAYS, EVANS, OR APPROVED EQUAL. FILTERS SHALL BE OF THE OPTIMUM THICKNESS AND DESIGN FACE VELOCITY SHALL NOT EXCEED 550 FPM. INSTALLATION OF THE AIR CONDITIONING UNIT SHA�� BE SUCH SO AS TO NOT IMPEDE ACCESS TO THE FILTERS. IF THE FILTERS ARE IN FRAME HOLDERS, THEN SUCH HOLDERS SHALL BE PROVIDED WITH A LEFf HANDLE. B. ELECTRIC RADIANT CEILING HEATERS 1. RADIANT CEILING PANELS SHALL BE STEEL CASING, DESIGN TO FIT A 2'X2' CEILING GRID, AND SHALL HAVE A RECESS FRAME FOR FINISH CONSTRUCTION. PANEL SHALL HAVE A 36" LONG PRE—WIRED FLEXIBLE CABLE. C. ALL UNITS WILL BE EQUIPPED WITH DYNELCO MULTISTAT TMC2—PC—AVU THERMOSTAT. UNIT TO BE EQUIPPED WITH A TANDEM DAY/NIGHT THERMOSTAT ARRANGEMENT. DESIGN AND STANDARD CONDITIONS FOR THERMOSTAT OPERATION WILL BE AS FOLLOWS: COOLING: 75 F MINIMUM OCCUPIED COOLING TEMPERATURE 85 F COOLING NIGHT SETBACK. HEATING: 72 F MAXIMUM OCCUPIED HEATING TEMPERATURE 68 F HEATING NIGHT SETBACK. D. THE HVAC SUBCONTRACTOR SHALL IDENTIFY ALL HVAC EQUIPMENT AND APPARATUS WITH 2" HIGH PAINTED STENCILED STORE NAME ON ALL SIDES OF EQUIPMENT. I�lIZ�l�i�l�l.�:f A. SQUARE AND RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME GRADE SHEET STEEL OF THE FOLLOWING GAUGES: DUCT SIZE GAUGE 12" AND LESS N0. 26 U.S. GAUGE 13" TO 30" N0. 24 U.S. GAUGE 55" TO 84" N0. 20 U.S. GAUGE 85" AND OVER N0. 18 U.S. GAUGE B. SQUARE AND RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED AS FOLLOWS: SIZE 17" AND LESS 18" TO 30" 31" TO 54" METHOD "S" AND DRIVE CLEATS "L" STANDING SEAMS ON 3'-0" CENTERS 1-1/4" STANDING SEAMS ON 3'-0" CENTERS ROUND DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME GRADE SHEET STEEL OF THE FOLLOWING GAUGES: DUCT SIZE {DIAMETER) DUCTS FITTINGS 8" AND LESS 24 22 9" TO 18" 22 20 19" TO 30" 20 18 ALL 9Q DEGREE ELBQWS FOR ROUND DUCTWORK SHALL BE FIVE (5) PIECE. ALL LONGITUDINAL SEAMS SHALL BE FORMED BY PITfSBURGH �OCKS. JOINTS SHALL BE SWAGGED WITH ONE—HALF INCH (1 /2") OVERLAP. C. ALL SUPPLY AIR DUCTS (HEATING AND COOLING) AND RETURN AIR DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED STEEL WITH MINIMUM 1" THICK INTERNAL ACOUSTICAL AND THERMAL INSULATION. A�� EXHAUST AND RE�IEF AIR DUCTS SHA�� BE GALVANIZED STEEL. D. CONTRACTOR WIL� INSTAL� INSECT SCREENS ON ALL DUCT OPENINGS WHICH �EAD TO OR ARE OUTDOORS. INSECT SCREENS SHALL BE 10 GAUGE, ONE—HALF INCH (1/2") MESH IN REMOVABLE GALVANIZED STEEL FRAMES. E. ALL DUCTWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE PROCEDURES DESCRIBED IN THE AMERICAN SOCIETY OF HEATING REFRIGERATION AND AIR CONDITIONING ENGINEERS GUIDE (ASHRAE) AND FABRICATED AND INSTALLED IN ACCORDANCE WITH THE LATEST METHODS RECOMMENDED IN THE SHEETMETAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA) LOW VELOCITY DUCT MANUAL, LATEST EDITION. HANGERS AND SUPPORTS: A. AL� HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND LESS SHALL BE SUPPORTED BY MEANS OF BAND IRON HANGERS OF N0. 18 U.S. GAUGE ATfACHED TO THE DUCT BY MEANS OF RIVETS, SCREWS, OR CLAMPS, AND FASTENED TO STRUCTURE ABOVE BY TOGGLE BOLTS OR OTHER MEANS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. VERTICAL DUCTS SHALL BE SUPPORTED WITH 1-1 /4" x 1-1 /4" x 1-1/4" ANGLES WHERE THEY PASS THROUGH THE FLOOR LINES. B. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND MORE SHALL BE SUPPORTED BY MEANS OF ANGLE IRON TRAPEZE HANGERS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. FLASHING: A. CONTRACTOR WIL� PROVIDE WATER TIGHT 24 GA. SHEET METAL FLASHINGS AT ALL EXTERIOR WALLS AND ROOF PENETRATIONS. B. ALL CUTTING OF ROOF OPENINGS, SUPPORTS FOR ROOF OPENINGS, PITCH PANS, ROOF CURBS, FLASHINGS, COUNTER FLASHINGS, REPAIR TO ROOF, ETC. ASSOCIATED WITH HVAC SUBCONTRACTOR SHALL BE THE RESPONSIBILITY AND PART OF THE CONTRACT HVAC SUBCONTRACTOR. HE SHALL EMPLOY THE LANDLORD'S ROOFERS FOR THIS WORK SO AS TO MAINTAIN THE ROOF BOND. DAMPERS: A. SPLITTER DAMPERS SHALL BE FABRICATED OF SHEET STEEL NOT LESS THAN N0. 16 U.S. GAUGE WITH THE LEADING EDGE HEMMED. EACH DAMPER SHALL BE LARGE ENOUGH TO COVER THE SMAL�ER OF THE TWO OPENINGS IT CONTROLS. DAMPERS SHALL BE CONTROLLED AS FOLLOWS: EXPOSED OR ACCESSIBLE DUCTWORK — �OCKING QUADRANTS EQUAL TO YOUNG REGULATOR N0. 1 WITH DAMPER ROD END BEARINGS ON OPPOSITE END. CONCEALED DUCTWORK — LOCKING QUADRANT EQUAL TO YOUNG REGULATOR N0. 315 (CHROMIUM PIATED WITH DAMPER ROD END BEARINGS ON BOTH ENDS). B. VOLUME DAMPERS SHALL BE OF THE OPPOSED INTERLOCKING TYPE AS MANUFACTURED BY AMERICAN FOUNDRY AND FURNACES C0. (AFFCO) OR EQUAL. BLADES SHALL BE OF N0. 16 GAUGE SHEET METAL AND SHALL NOT EXCEED 48" IN �ENGTH OR 12" IN WIDTH. BLADES SHALL BE ON ONE—HALF INCH (1/2"" DIAMETER RUSTPROOF AXLE. BEARINGS SHAL� BE OF THE SE�F—LUBRICATING FERRULE TYPE. C. JOB FABRICATED TURNING VANES SHALL BE ACCEPTABLE IN SQUARE ELBOWS. PROVIDE AND INSTALL BARBER—COLMAN AIRTURNS OR EQUAL. TURNING VANES SHALL BE OF THE SAME GAUGE METAL AS THE DUCT IN WHICH THEY ARE INSTALLED. RADIUS ELBOWS SHALL HAVE A CENTERLINE RADIUS OF ONE AND ONE—HALF (1-1/2) TIMES THE DUCT WIDTH. SUPPORT OF DUCT SYSTEM: DUCTWORK SHALL BE SUPPORTED AT A�� TURNS AND TRANSITIONS AND NOT MORE THAN 8' O.C. FOR STRAIGHT DUCTS UP TO 35" TO 59" MAXIMUM DIMENSION, 6' O.C. AND DUCTS OVER 60: MAXIMUM DIMENSION, 4' O.C. HANGER DESIGN SHALL BE AS DESCRIBED IN THE LATEST EDITION OF THE "SMACNA" MANUA�. REINFORCEMENT MEMBERS MAY BE USED TO SUPPORT THE DUCT SYSTEM PROV►DED DETAILS OUTLINED IN THE AFOREMENTIONED DOCUMENTS ARE ADHERED T0. f:��11►I��I:iy�(�t�1iY� ALL DUCTS REQUIRING REINFORCEMENT SHALL BE REINFORCED ACCORDING TO THE LATEST EDITION OF "SMACNA" MANUAL. MATERIALS FOR REINFORCEMENT MEMBERS SHALL BE GALVANIZED STEEL. ALL SCREWS AND WASHERS SHALL BE PLATED OR GALVANIZED. ACCESSORY ITEMS: ALL MANUAL DAMPERS, FIRE DAMPERS, TURNING VANES, REGISTER CONNECTIONS, ACCESS DOORS OR OTHER ASSOCIATED ACCESSORIES SHALL BE INSTALLED ACCORDING TO THE LATEST PUBLICATION OF "SMACNA" MANUAL. PIPING: A. PIPING AND FITTINGS SHALL BE OF THE WEIGHTS AND TYPES SHOWN ON THE DRAWINGS. SIZES SHOWN ON THE DRAWINGS ARE NOMINAL PIPE SIZES. B. AL� PIPING SHALL BE INSTALLED PARA�LEL T0, OR AT RIGHT ANGLES WITH THE BUILDING WALLS AND PARTITIONS AND SHAL� BE INSTALLED WITH THE PROPER PITCH. C. ALL PIPING SHALL BE UPENDED AND POUNDED TO REMQVE ANY FOREIGN MAITER PRESENT AND SHALL BE SWABBED IF NECESSARY. TESTING AND ADJUSTING: CONTRACTOR WILL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, WILL BALANCE AIR FLOW IN ACCORDANCE WITH AIR QUANTITIES ON DRAW►NGS AND WILL RECORD VOLUME READINGS IN ACCORDANCE WITH ASHAE AND PROVIDE SAME TO TENANT. GAS PIPING SHA�� WITHSTAND AIR PRESSURE TESTING PER UNIFORM PLUMBING CODE. GUARANTEE: ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFfER DATE OF ACCEPTANCE. THE COMPLEfED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY TENANT SHAL� BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THIS SUBCONTRACTOR WITHOUT ADDITIONAL CHARGE TO THE TENANT. SEQUENCE OF OPERATION: A. ROOF UNIT SHALL BE CONTROLLED BY A WALL MOUNTED, 7—DAY PROGRAMMABLE THERMOSTAT. DURING THE OCCUPIED MODE, THE SUPPLY FAN SHALL RUN CONTINUOUSLY, THE OUTSIDE AIR DAMPER SHALL BE OPEN, AND THE COMPRESSORS AND/OR ELECTRIC HEAT SHALL CYC�E TO MAINTAIN SPACE TEMPERATURE SET POINT OF 75'F (ADJUSTABLE). B. DURING THE UNOCCUPIED MODE, THE OUTSIDE AIR DAMPER SHAL� BE CLOSED, AND THE SUPPLY FAN, AND ELECTRIC HEAT SHALL CYCLE TO MAINTAIN THE NIGHT SET BACK TEMPERATURE (55°F) ADJUSTABLE. •�• • PROVIDE MODIFICATIONS TO EXISTING SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. PROVIDE TEMPORARY FIRE PROTECTION DURING THE BUILDING CONSTRUCTION PHASE. FIRE PROTECTION WORK SHAL� BE IN STRICT ACCORDANCE WITH NFPA 13 — STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS AND NFPA 14 — STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS. FIRE PROTECTION SYSTEMS AND EQUIPMENT SHALL INCLUDE PIPING, VALVES, SPRINKLERS, PIPING TESTS, ETC., FOR A COMPLEfE WORKING SYSTEM. PRODUCTS AND MATERIALS UTILIZED FOR FIRE PROTECTION SERVICE SHALL BE UL LISTED AND FM APPROVED FOR THE INTENDED PURPOSE. SUGGESTED SPRINKLER LOCATIONS ARE SHOWN ON THE MECHANICAL PLANS. THE SPRINKLER LAYOUT IS SYMMETRICAL WITH RESPECT TO WALLS AND CEILING GRID. ANY DEVIATION FROM THIS lAYOUT MUST BE APPROVED BY THE ARCHITECT. PROVIDE ADDITIONA� SPRINKLER HEADS AS REQUIRED TO MEET NFPA 13 FOR ADVERSE CONDITIONS, BEAM AND BULKHEAD CONDITIONS, ETC. THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE THE LOCATION OF SPRINKLERS AND PIPING WITH ALL TRADES TO INSURE THAT THE ADEQUATE SPACE IS AVAILABLE FOR INSTALLATION OF EQUIPMENT. SOME REVISIONS TO THE SPRINKLER PLANS MAY BE REQUIRED AS A RESULT OF COORDINATION WITH OTHER TRADES. NO EXTRA CHARGES SHALL BE ALLOWED FOR REVISIONS RESULTING FROM COORDINATION ISSUES. UNIT PRICES FROM THE BID FORM SUPPLEMENT SHALL BE USED TO DETERMINE COMPENSATION FOR OTHER SITUATIONS. THE CONTRACTOR SHALL INVESTIGATE THE EXISTING CROSS MAINS AND BRANCH LINES AND COORDINATE ALL RELOCATIONS DUE TO INTERFERENCE WITH NEW WORK. SPRINKLERS INDICATED AS NEW OR RELOCATED WITHIN THE CEILING OF THE BANK SHALL BE NEW CONCEALED TYPE SIMILAR TO "STAR" QUASAR MODEL 0 WITH A TEMPERATURE RATING OF 135°F AND COLOR SHALL BE SELECTED BY THE ARCHITECT. THE CONTRACTOR SHALL BE RESPONSIBLE TO RELOCATE EXISTING STORE SPRINKLERS AND/OR PROVIDE NEW SPINKLERS TO MATCH EXISTING AS REQUIRED TO PROPERLY PROTECT THE STORE AREA IN ACCORDANCE WTH NFPA 13 AS A RESULT OF THE NEW BANK CONSTRUCTION. SpENCER BRISTOI. ENC�INEERING, INC. 5655 PFncl�7rzEE �'Ar:kwny, SuirF 100 NoacRoss, GEoaciA 3009`L TEL 770.h14.1628 Fnx 770.414.602h s�F r���oiE�T No. �so� NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made only by the Architect. C EFT R1 C EFT R1 10 ' 6'-3"4'-11" Bank Space 636 sq ft Work Rm.82 sq ft Teller/Office 514 sq ft INTERIOR IMPROVEMENTS Carmel Giant Eagle Market District (Store 6550) Tenant Fit Out A0.0 COVER SHEET 05 - 0 6 - 1 5 BW S Is s u e f o r P e r m i t / C o n s t r u c t i o n 11505 Illinois Street Carmel, IN 46032 : : : De s c r i p t i o n Is s u e d Da t e Ma r k DR A W I N G I S S U E & R E V I S I O N S T A T U S ©  2015 CARLSON ASSOCIATES, INC. CHK'D BY DRAWN BY PROJECT # 15-20-151500 NOTICE: As an instrument of service, this Drawing is the property of the Architect and may be used only for this Project. Modifications to this Drawing may be made only by the Architect. 14 9 0 1 Q u o r u m D r i v e , S u i t e 5 9 5 Da l l a s , T X 7 5 2 5 4 ww w . c a r l s o n - d c . c o m Te l : 9 7 2 . 2 5 0 . 3 9 7 2 F a x : 9 7 2 . 2 3 3 . 7 5 7 5 Ca r l s o n co n s u l t i n g . d e s i g n . c o n s t r u c t i o n Gi a n t E a g l e S t o r e 6 5 5 0 11 5 0 5 I l l i n o i s S t r e e t Ca r m e l , I N In t e r i o r I m p r o v e m e n t s No. AR10400002 CYUG .TOR O T E C TIHCRA SIGER TERE D A N AIDNI STATE OF Date: 05/06/15