HomeMy WebLinkAboutCIE_RevisedSet_031615.pdfMECHANICAI. &
ELECTRICAL NOTES
1. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE SUPPRESSION, AND
FIRE ALARM SYSTEMS SHALL BE DESIGNED AND INSTALLED BY THE
RESPECTIVE DESIGN/BUILD CONTRACTORS PER AGREEMENT WITH THE
OWNER. A�L TRADES SHAL� DESIGN AND INSTALL THEIR RESPECTIVE
SYSTEMS IN ACCORDANCE WITH ALL APPLICAB�E STATE AND LOCA�
BUI�DING CODES. COORDINATE WITH THE ARCHITECT IF ADDITIONAL
INFORMATION IS RE UIRED IN ORDER TO DO THE WORK IN TNE FIELD.
Q
SCHOTT DESIGN, INC. DOES NOT HAVE CHARGE OR RESPONSIBILITY FOR
TNE DESIGN OR INSTA�LATION OF SYSTEMS EXECUTED AS DESIGN/BUILD
WITH THE OWNER.
2. H.V.A.C. WORK GENERALLY INDICATED BY THIS DRAWING IS TO BE
PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT.
PROVIDE A FUNCTIONAL, COMFORTABLE ENVIRONMENT AND A
COMPLETE, WORKING SYSTEM. COMP�Y WITH THE INDIANA
MECHANICAL CODE AND AL� OTNER APPLICABLE CODES.
3. VERIFY NEAT LOADS OF ANY SPECIAL EQUIPMENT IN TNE TENANT
SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM
WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQUIPMENT. REVISE
ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFFICE SPACE TO BE
ON A SPLIT ZONE UNLESS APPROVED BY BUILDING OWNER/LAND�ORD.
4. RELOCATE AIR-SUPP�Y DIFFUSERS AND RETURN-AIR GRILLES AS
REQUIRED. PROVIDE PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR
FROM RETURN AIR GRILLES. LOCATION OF DIFFUSERS SHOWN ON P�AN IS
FOR REFERENCE ONLY. CONTRACTOR IS TO P�ACE LOCATION OF
DIFFUSERS AND RETURN AIR GRIL�ES AS REQUIRED BY CODE.
5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER
MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING
OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS.
b. E�ECTRIC POWER WORK GENERA��Y INDICATED BY THIS DRAWING IS
TO BE PROVIDED BY DESIGN/BUI�D SERVICES UNDER THE GENERAL
CONTRACT. PROVIDE A COMP�ETE, WORKING SYSTEM.
7. COMPLY WITH TNE INDIANA E�ECTRICAL AND MECHANICAL CODE
AND ALL OTNER APP�ICABLE CODES.
8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE
ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED.
9. A�L ELECTRICAL OUTLETS WITHIN b'-0" OF WATER ARE TO BE G.F.C.I.
10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM
ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE
FOR PU�LING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS
AT FACE PLATE.
1 1. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUT�ETS &
SWITCHPLATES TO MATCH EXISTING, UN�ESS OTHERWISE NOTED.
ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCNASE.
12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS
WHERE SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE
DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR.
ELECTRICIAN TO MAKE FINA� CONNECTION FROM WORKSTATION WHIP
TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR
WIRING THE BASE PANELS OF THE WORKSTATIONS.
13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION
FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR
TO RUNNING E�ECTRICAL CONDUITS TO JUNCTION BOXES.
14. E�ECTRIC �IGHTING WORK GENERALLY INDICATED BY THIS DRAWING
IS TO BE PROVIDED BY DESIGN/BUI�D SERVICES UNDER TNE GENERA�
CONTRACT. PROVIDE A COMPLETE, FUNCTIONAL SYSTEM.
15. VERIFY EXISTING LIGNTING CIRCUITING. SIZE NEW CIRCUITS AS
REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW
LAYOUT OF �IGHT FIXTURES.
1 b. ENSURE TNAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET
A.D.A. REQUIREMENTS.
17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIQE (1) GANG BOX
WITH A SINGLE COVERPLATE.
18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSEd
DOWNLIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS
UN�ESS OTHERWISE NOTED.
19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED
TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE
CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON P�AN ARE FOR
REFERENCE ONLY.
20. PROVIDE ALA12M NOTIFICATION APPLIANCES (HORNSISTROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER
REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL
APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL
FIRE CODE, NFPA).
21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF
FIRE DETECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID
CONFLICT WITH FEATURE WAL�S (CONFERENCE ROOMS AND RECEPTION
AREAS) AND TENANT-INSTA�LED ITEMS (I.E. PRESENTATION BOARDS, A/V
EQUIPMENT AND PROJECTION SCREENS).
22. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND
LAMPS IN AL� �IGHTS IN EXISTING SPACES. CONSULT WITH �AND�ORD.
FIRE PROTECTION NOTES
TNE FOLLOWING NOTES APPLY ON�Y IN EXISTING SPRINKLERED FACILITIES.
1. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER TNE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE
DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM.
2. THE DESIGN/BUI�D CONTRACTOR SHALL COMPLY WITH THE INDIANA
BUI�DING CODE, TNE INDIANA FIRE CODE, AND ALL OTNER APPLICAB�E
LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND
INSTA��ATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS.
3. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FI�E THOSE DRAWINGS, AND RE�ATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES NAVING
JURISDICTION OVER THE PROJECT.
4. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS
REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR
SPRINKLER NEADS WHERE APPLICABLE. FIE�D VERIFY EXISTING
CONDITIONS PRIOR TO TNE START OF WORK.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE A�� NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTA��ED ACCORDING TO NFPA 10.
COORDINATE WITH OWNER/�ANDLORD ON EXTINGUISHER TYPE ANQ
HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO
A VISIB�E EXTINGUISHER.
GENERAL PROJECT NOTES
1. AL� WORK SHA�� COMP�Y WITH THE REQUIREMENTS OF THE EXISTING BUI�DING 18. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW
CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE . SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND
DELIVERY OF MATERIA�S AND EQUIPMENT.
2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE
AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING 19. ENSURE THAT A�L MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST
THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF QUA�ITY STANDARDS OF EACN RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE
WORK. GENERAL CONTRACTOR IS RESPONSIB�E FOR ENSURING THAT ALL WORK IS IN
ACCORDANCE WITN A�L FEDERAL, STATE, AND �OCAL BUILDING CODES, AND
3. CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. TNE STANDARDS FOR GENERA�, MECHANICA�, AND ELECTRICAL CONSTRUCTION.
DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING
CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHA�� MAKE 20. ALL DETAI�S, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY
THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FU��Y SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER.
AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK.
21. REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL
4. FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WI�� NOT BE APPROVED
FOR ANY CONDITIONS OR CONF�ICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY
CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS
PREVENT OBTAINING RESU�TS AS SHOWN OR SPECIFIED. DO NOT SCA�E DRAWINGS. TNE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT.
NOTED DIMENSIONS TAKE PRECEDENCE.
22. FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS,
5. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASNED ON THIS DRAWING
DISCREPANCY TNROUGN THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC. AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO
BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED.
6. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING
ALL ON-SITE ACTIVITIES; SUCN AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS 23. REPAIR GYPSUM WAL�BOARD WHERE DEMO�ITION HAS OCCURRED AT
STORAGE AND NANDLING, DE�IVERIES, ACCESS TO THE WORK SITE, TRAFFIC REMAINING WAL�S. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION.
CONTRO�, AND BUILDING/PUB�IC SAFETY PROCEDURES DURING CONSTRUCTION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO
THE CONTRACTOR SNAL� ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN EXISTING CORE WALLS.
ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE.
24. PATCH ALL GYPSUM WAL�BOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH
7. THE GENERAL CONTRACTOR SHA�L COORDINATE WITH THE LANDLORD, DAILY DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND
WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO PREPARE FOR FINISH.
AND DURING HOLIDAYS. �AND�ORD RESERVES THE RIGHT TO RESTRICT
CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED 25. ALL MECHANICAL, E�ECTRICA�, PLUMBING, FIRE SUPPRESSION, AND FIRE ALARM
TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. SYSTEMS SHALL BE DESIGNED AND INSTAL�ED BY THE RESPECTIVE DESIGN/BUILD
CONTRACTORS PER AGREEMENT WITH THE OWNER. A�� TRADES SHALL DESIGN AND
8. FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR INSTAL� THEIR RESPECTIVE SYSTEMS IN ACCORDANCE WITH ALL APP�ICABLE STATE
SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE AND LOCA� BUILDING CODES. COORDINATE WITH THE ARCHITECT IF ADDITIONAL
TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED INFORMATION IS REQUIRED IN ORDER TO DO TNE WORK IN THE FIELD. SCHOTT
IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, DESIGN, INC. DOES NOT HAVE CHARGE OR RESPONSIBILITY FOR THE DESIGN OR
TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIB�E FOR DELAYS RESULTING INSTAL�ATION OF SYSTEMS EXECUTED AS DESIGN/BUI�D WITH THE OWNER.
FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES.
26. WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR(S) SHA�� PROVIDE
9. SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED DESIGN/BUILD DRAWINGS FOR MECNANICA�, PLUMBING, ELECTRICAL, OR FIRE
WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUPPRESSION. DRAWINGS SHA�L BE CERTIFIED BY A �ICENSED ENGINEER AND
SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW.
ALLOW REASONABLY SUFFICIENT TIME FOR TNE DESIGNER TO REVIEW THE REQUEST
AND RENDER A DECISION. 27. ALL EQUIPMENT ANDiOR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS.
10. SCHOTT DESIGN, INC., SHALL NOT HAVE CONTRO� OVER, OR BE IN CHARGE OF,
AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, 28. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
METNODS, SCNEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHA�� BE COMPLETION OF THE PROJECT. AL� SURFACES, FIXTURES, AND EQUIPMENT SHALL BE
RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE C�EAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION
PUBLIC AT ALL TIMES. THAT REPRESENTS THE HIGHEST �EVEL OF CARE AND PROFESSIONALISM. ENSURE ALL
GENERAL CONTRACTOR INSTA�LED APPLIANCE S WORK & DO NOT LEAK.
1 1. THE GENERA� CONTRACTOR SHA�� ESTABLISH WITH THE LAND�ORD C�EANUP
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO 29. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUA�S, OR
CONDUCT BUSINESS IN A SAFE AND C�EAN ENVIRONMENT. INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT TNE COMPLETION OF TNE
PROJECT.
12. THE GENERAL CONTRACTOR SHA�L COORDINATE WITH THE �ANDLORD, AN
AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND 30. ALL P�AN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW
PARKING CONSTRUCTION AND DELIVERY VENICLES. THE USE OF EXISTING REST ROOM GYPSUM BOARD WA�L, OR FACE TO FACE OF NEW GYPSUM BOARD WAL�. DO NOT
FACI�ITIES SHALL BE APPROVED BY TNE �ANDLORD. ONLY THOSE DESIGNATED AREAS SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN.
SHAL� BE USED BY CONSTRUCTION CREWS.
31. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW
13. TNE GENERAL CONTRACTOR SNA�L USE DUST PARTITIONS TO MINIMIZE BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW B�INDS WITH NEW TO MATCH
DISTURBANCES OF DAI�Y TENANT OPERATIONS DURING DEMOLITION AND BUI�DING STANDARD.
CONSTRUCTION WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD
STUDS @ 24"O.C., INSULATION AND b MIL VAPOR BARRIER ON EACH SIDE. 32. THE GENERA� CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYWG THE
REQUIREMENTS REGARDING �OCAL P�AN REVIEW, PERMITS, INSPECTIONS, AND FEES.
14. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE THE GENERAL CONTRACTOR SHA�� BE RESPONSIBLE FOR SUBMITTING A�� REQUIRED
DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCA� BUILDING OFFICIA�
INSTA��ATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. AND/OR PERMIT DEPARTMENT. A�L REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY
WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE
�IGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). OWNER/CONTRACTOR AGREEMENT.
15. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, 33. FIRE SEA� ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS
PRESENCE, HANDLING, REMOVA�, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, WITH APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.
THAT OF HAZARDOUS MATERIA�S IN ANY FORM ON THE PROJECT SITE.
34. WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED
1 b. PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS PARTITIONS, GYPSUM WALLBOARD WAL� TO BE SCRIBED TO FIT TIGH7, CAULKED AND
INCLUDING MILLWORK, WAL� STOPS, CABINETRY, ETC. FIRE DAMPERED IF REQUIRED.
17. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, 35. CONTRACTOR TO A��OW FOR UN�EVEL FLOOR CONDITIONS. A�� EXISTING F�OOR
WC. FOR APPROVA� ON ALL MATERIALS OR ITEMS WHERE TNE CONTRACTOR AND WALL SUBSTRATES SHALL BE LEVE�ED AND PATCHED AS REQUIRED TO RECEIVE
CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED.
DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODE� NUMBER.
DEMOLITION NOTES
1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO 7. REMOVE ALL ELECTRICAL OUT�ETS AND CONDUCTORS AS REQUIRED OR INDICATED. SA�VAGE
DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SA�VAGE REUSAB�E ITEMS. OUTLETS FOR REUSE IN NEW CONSTRUCTION.
2. NO STRUCTURA� OR �OAD-BEARING CONSTRUCTION SHA�L BE REMOVED, DEMOLISHED, OR 8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID INSTRUCTIONS.
DAMAGED AS A RESU�T OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE
DRAWINGS. PROTECT ALL EXISTING STRUCTURA� MEMBERS C}URING DEMOLITION%CONSTRUCTION. 9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH
THE CONTRACTOR SHA�� VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE AS, BUT NOT �IMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, �IGHT
DEMOLISHED ARE NOT STRUCTURAL CONTACT SCHOTT DESIGN IMMEDIATELY IF TNE FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. TNE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT
NT A T IN THE FIEL PE T THAT AN ITEM N TED F R DEM LITI N PPEAR T BE TNE CONTRACTOR'S COST ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE
CO R C OR(S) D SUS C O O O O A S O
STRUCTURAL OR OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS OTHERWISE BEEN REASQNABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S
THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION USE IN THE PROJECT.
WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND STRUCTURAL
MEMBERS. THE CONTRACTOR IS SO�E�Y RESPONSIBLE FOR INADVERTENT DAMAGE TO THE 10. PER TNE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION) REMOVE ALL
BUI�DING STRUCTURAL SYSTEM. ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA
WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC
3. PRIOR TO DEMO�ITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING THOSE ITEMS CABLES/RACEWAYS, AND PLTC CABLES. REFER TO SECTION 300.21.
THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE ITEMS THE OWNER
CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF WHICH THE OWNER CHOOSES TO 1 1. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL,
DISPOSE. COMP�Y WITH THE OWNER'S REQUESTS. OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SNALL BE CLOSED AND PROTECTED IN STRICT
ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGU�ATIONS OR PROCEDURES.
4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE MARK, LABE�, OR FLAG A�L TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE
BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE AN "AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS.
OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE TNE
ITEMS WERE RELOCATED, UN�ESS OTHERWISE DIRECTED BY OWNER. 12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO TNE BUILDING OWNER/LAND�ORD ON
ALL ITEMS BEING DEMO�ISHED, SUCH AS, METAL STUDS, DRYWALL, CARPET, CEILING TILES, DOORS,GLASS,
5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASNED AND CABINETRY. �
�INES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN QN DEMOLITION P�AN. VISIT AREA OF
WORK TO ASSURE EXTENT OF DEMO�ITION.
6. REMOVE ALL CARPET, VINYL BASE, VCT, WA�L FABRIC, AND ANY OTHER FINISHES AS REQUIRED
FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER TO FINISH
PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN.
EFFECTIVE CODES
- GAR - GENERAL PROVISIONS (675 IAC 12-1.1)
- INDIANA BUILDING CODE, 2014 EDITION (IBC, 2012 EDITION, 1ST PRINTING) ANSI A117.1-2009
- INDIANA PLUMBING CODE, 2012 EDITION
- INDIANA E�ECTRICA� CODE, 2009 EDITION (NFPA 70-2008)
- INDIANA MECHANICAL CODE, 2014 EDITION (IMC, 2012 EDITION, 1ST PRINTING)
- INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1, 2007 EDITION, AS AMENDED)
- INDIANA FIRE CODE, 2014 EDITION (IFC 2012 EDITION, 1ST PRINTING)
FINISH NOTES MILL/CASEWORK NOTES
1. AL� FINISHES SHA�L COMPLY WITN CHAPTER 8(INTERIOR FINISNES) OF THE 1. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE
INDIANA BUI�DING CODE FOR CLASS A FIRE RATINGS. PROVIDED UNDER TNE GENERAL CONTRACT.
2. FOR ALL NEW DRYWAL� INSTAL�ATIONS, INSTALL AS RECOMMENDED BY THE 2. UNLESS INDICATED QTHERWISE, COMP�Y WITH ARCHITECTURAL WOODWORK INSTITUTE
GYPSUM ASSOCIATION. (SUCN AS, CONTROL JOINTS, FINISH �EVELS, FASTENERS, (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.
TAPING DETAILS, CORNER BEADS, ETC.)
3. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE
3. ALL NEW P�ATES AND SWITCHES ARE TO MATCH EXISTING COLOR, UNLESS TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION.
OTNERWISE NOTED. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH
AFTERWARDS. CONTRACTOR TO CONFIRM EXISTING COLOR PRIOR TO PURCHASING 4. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON
NEW. P�ANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE
4. ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH ADJUSTMENTS TO CASEWORK AND MIL�WORK TO FIT FIELD CONDITIONS UNLESS DOING SO
COATS. WI�L SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.
5. FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR 5. VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION
OPENINGS TO MATCH VINY� BASE COLOR (IE.: WHERE VCT MEETS CARPET). DRAWINGS WITN FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY
REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERA� CONTRACTOR.
6. WHERE LIMITS OF WORK ARE SNOWN, OTHER INCIDENTAL WORK LIKE PAINTING
WHERE NEW OUTLETS HAVE BEEN INSTAL�ED, IS CONSIDERED PART OF TNE SCOPE 6. REFER TO MILLWORK SECTIONS & E�EVATIONS . UNLESS OTHERWISE SNOWN, PLASTIC
OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSP�ASHES WHERE INDICATED. BACKSPLASHES
AND BUI�DING OWNER. TO BE FIE�D APP�IED.
7. REFINISH SURFACES TO MATCH EXISTING WHERE DEMO�ITION HAS OCCURRED. 7. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS (CUSTOM
P�ASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINETRY).
8. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT
TO MATCH ADJACENT WALL FINISH. 8. TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND
CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.
9. SUBMIT FINISH SAMPLE OF MI��WORK (STAINED OR PAINTED AS SPECIFIED) TO D O C 11 M E N T A P P R
SCHOTT DESIGN FOR REVIEW AND APPROVA� PRIOR TO TNE FINISHING PROCESS OF
ALL MILLWORK.
10. REFERENCE INTERIOR ELEVATION & SECTIONS WNERE PROVIDED FOR ': TENANT�C�IENT, UPON SIGNATUI
ADDITIONA� FINISH INFORMATION.
1 1. ALL PAINTS AND ADNESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.
12. ALL ADHESIVES/SEA�ANTS TO BE USED AS RECOMMENDED BY PRODUCT ' TENANT/CLIENT COMANY NAME
MANUFACTURER.
NOT TO SCALE
KEY PLAN - 1 ST FLOOR
NOT TO SCAI.E
N
INDEX OF DRAWINGS
T1 1 1 COVER SHEET AND GENERA� PROJECT NOTES
L100 �IFE SAFETY PLAN
D111 DEMOLITION PLAN
A1 1 1 ARCHITECTURAL FLOOR PLAN
A121 REFLECTED CEILING PLAN: HVAC / �IGHTING
A131 FINISH P�AN
A21 1 DOOR SCHEDULE / INTERIOR DETAILS
A212 INTERIOR DETAILS
El 1 1 ELECTRICA� PLAN
O �
� N O
� � o �
� � �
-�--
cn Z '�n
- t� N
� ,vi � �
a` Q t� O
W � � U
O � a?
� .� Q 3
� 3
- 3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTE�IECTl1AL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
SSUE
02.02.15 REVIEW SET
02.06.15 STATE SUBMITTAL
03.12.15 A121 UPDATE
03.16.15 A111/A211/E111 NOTES
visoNs
DB IDESCRIPTION
PROJECT NUMBER
2014.423
PROJ. MGR DRAWN BY
MJ SS
1 ST FLOOR
COVER SHEET AND
GENERAL NOTES
2
3
4
5
6
7
8
9
10
11
12
� � � . � • . � �
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE
OCCUPANCY C�ASSIFICATION B(USINESS)
CHANGE OF OCCUPANCY CLASS? NO
TOTA� BUILDING AREA 35,386 SF/FLOOR X 3 STORIES = 106,158 SF
TOTA� PROJECT AREA 5,233 SF
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
GEN. OFFICE 5,233 SF 100 53
TOTAL OCCUPANTS IN PROJECT AREA 53
NUMBER OF REQUIRED EXITS 2
SPRINK�ER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0 SF
TOTA� AREA ON THE FLOOR 35,386 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE WALLS, AND/OR OCCUPANCY N/A
SEPARATIONS (IF REQUIRED)
LEGEN D
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT
FE FIRE EXTINGUISHER
EXIT SIGNAGE
EMERGENCY LIGHTING
� NIGHT IIGHT/EMERGENCY LIGHTING
NLEL
%
■
�
1. PROVIDE EMERGENCY �IGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED
TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE
CONTAINS 50 PERSONS OR MORE. FIXTURES SNOWN ON P�AN ARE FOR
REFERENCE ONLY.
2. PROVIDE A�ARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER
REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL
APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL
FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMP�ETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE
DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FI�E THOSE DRAWINGS, AND RE�ATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES NAVING
JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE A�� NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTA��ED ACCORDING TO NFPA 10.
COORDINATE WITH OWNER/�ANDLORD ON EXTINGUISHER TYPE AND
HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO
A VISIB�E EXTINGUISHER.
�l . REFER TO SHEET Al 1 1 FOR WALL TYPE AND CONSTRUCTION DETAILS
L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS,
FIRE PU�LS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS
AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCA� AND
STATE CODES.
AREA NOT IN CONTRACT
AREA OF WORK
LIFE SAFETY PLAN
0 4' 8' 16'
��
�
� �
O
� � o �
� � �
-�--
cn Z '�n
— t� N
� ,vi � �
Q` Q t� O
W � � U
O � N
�� �-3
� 3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTE�IECTl1AL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
SSUE
�
�
o�
N
�
�
��
W
�
�
Q
U
02.02.15 REVIEW SET
02.06.15 STATE SUBMITTAL
03.12.15 A121 UPDATE
03.16.15 A111/A211/E111 NOTES
visoNs
�
PROJECT NUMBER
2014.423
N
PROJ. MGR DRAWN BY
MJ SS
1 ST FLOOR
�IFE SAFETY
f�:l���l�[c�ti73�;T�►�i[�ITL����:/�'����C�t�l;Z�►TiI_�I�'
------ WALL
WA��
���s�� PAI2TIAL HEIGHT WALL �--�� PARTIAL HEIGHT WALL
c�� DOOR AND FRAME � DOOR AND FRAME
� _�.�
-�--{- WINDOW / SIDELIGHT j--E—� WINDOW / SIDELIGHT
�-----� CEI�ING GRID AND
�_____� TILES, 2'x4'
�--�--� CEI�ING GRID AND
�__�__� TILES, 2'x2'
�-�
' �C m SUPP�Y AIR DIFFUSERS
�c_�
c���c�
� �Q.` � EXHAUST FAN
L=J
�� =_�� LIGHT FIXTURE,
i.L __ �.�i FLUORESCENT, 2'x4'
r-� LIGHT FIXTURE,
�L=J FLUORESCENT, 2'x2'
,r.� LIGHT FIXTURE, CAN
�----i LIGHT FIXTURE,
FLUORESCENT
cv c�
�-� � �-+ LIGHT FIXTURE, TRACK
L�
?".� LIGHT FIXTURE, SCONC
LIGHT FIXTURE,
u� PENDANT
� LIGHT SWITCH
�y^ EXIT LIGHT
���
�-� EMERGENCY LIGHT
�� � E�ECTRIC OUT�ET(S)
�g�tp����
.�.�.�
DATA OR
��� COMMUNICATION
OUT�ET
NOTE: EXISTING FIXTURES TNAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
D01 REMOVE EXISTING SUITE ENTRY DOORS AND SIDELIGHTS. SEE DOOR
SCHEDULE ON SHEET A21 1 FOR NEW DOOR AND FRAME SYSTEM.
'
■
AREA NOT IN CONTRACT
AREA OF WORK
'! • • ' �
� �`
�
� �
O
� � O �
} � �
cnZ�'�
� ,vi � �
Q` Q t� O
W � � U
o � N
�� �-3
� 3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTE�IECTl1AL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
SSUE
02.02.15 REVIEW SET
02.06.15 STATE SUBMITTAL
03.12.15 A121 UPDATE
03.16.15 A111/A211/E111 NOTES
visoNs
�
PROJECT NUMBER
2014.423
PROJ. MGR DRAWN BY
MJ SS
1 ST FLOOR
DEMOLITION PLAN
,
�c�i�
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
W?
�Q WINDOW / SIDELIGHT
## DOOR AND FRAME
(SEE DOOR SCHEDU�E)
WA��
��- WINDOW / SIDELIGHT
�DOOR AND FRAME
_�
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
♦ ' �
NOTE:
ALI. PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
All WALLS ARE TO BE W1 UNLESS OTHERWISE NOTED.
NOT AI.L WALI TYPES LISTED BELOW ARE NECESSARII.Y USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
W� WAL� WITH INSU�ATION
35�g " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5/$' TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WAL� TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WAL� ABOVE
CEILING
W2 DEMISWG WAL� WITH SECURITY MESH
35�g " METAL STUDS AT 16" O.C.;
ONE LAYER OF 5/g" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WA�� AND 2'-0" SOUND BATT INSU�ATION
EACH SIDE OF WALL ABOVE CEILING;
PROVIDE META� SECURITY MESH ON TOP OF
WALL ABOVE CEILING TO DECK
DEMISING WALL TO DECK
W3 WITH INSUL.ATION
3�g" METAL STUDS AT 16" O.C.;
ONE LAYER OF %g" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERG�ASS SOUND BATT INSU�ATION INSIDE
WALL
NOTE: CAREFULLY TRANSITION FROM THE
VERTICAL FACE OF THE DRYWAL� TO THE
CEILING DECK (OR OTHER CEILING ELEMENT)
SO PAINT LINE BETWEEN THE TWO SURFACES
WILL NAVE A STRAIGHT AND FINISHED
APPEARANCE ON CORRIDOR SIDE OF WA�L
WHERE CEILING IS EXPOSED TO TNE DECK.
METAL STUD
EXISTING WIN
MULLION
wA«
THICKNESS
�
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
�INE OF EXISTING WINDOW
SIL� COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEA�ANT
�.x �, .�
� WAL� AT MU��ION D ETAI L
A>>> NOT TO SCALE
[c � • ���?
1. SEE SHEET El 1 1 FOR INTENDED FURNITURE LAYOUT.
SS
1 /2" ANODIZEC
ALUMINUM REVEAI
PLASTIC �AMINATE
PANEI
F
2 DETAI L
A>>> NOT TO SCALE
A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFI��S OR WNERE NEW WALLS
ARE IN �INE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x4", PAINTED WITH FIRE
A02 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
A03 NEW FIRE EXTINGUISHER IN RECESSED WALL CABINET TO BE
PROVIDED AND INSTA��ED BY CONTRACTOR. PAINT CABINET TO
MATCH ADJACENT WALL FINISH. ALL FIRE EXTINGUISHERS ARE TO
BE INSTAL�ED ACCORDING TO NFPA 10.
A04 CONSTRUCT NEW WAL� AROUND EXISTING EXPOSED COLUMN AS
TIGHTLY AS POSSIBLE. CONSULT WITH SDI IF COLUMN WRAP
GREATLY AFFECTS DESIGN INTENT AS SNOWN ON PLAN.
A05 P�ASTIC LAMINATE PANE� WITH APPROPRIATE SUBSTRATE.
UNDERLAP SUBSTRATE SUCH THAT SURFACE APPEARS
CONTINUOUS. TOP CAP TO BE SS-1, 1"THICK X WIDTH OF
ADJACENT WA�L. TOP OF WAL� CAP TO BE AT 3'-6" A.F.F. PUT A
REVEA� BETWEEN TOP OF THE WA�L AND TOP CAP AS SHOWN IN
DETAIL 2/Al 1 1. SEE SHEET A131 FOR MORE DETAIL.
A06 ALIGN NORTH FACE OF CASEWORK WITH SOUTH FACE DOOR
FRAME 05 AS SHOWN.
A07 PROVIDE �EVEL 5 FINISH PER MANUFACTURER'S
RECOMMENDATIONS FOR WA�L INDICATED TO ALLOW FOR
SMOOTH APP�ICATION OF INTENDED SPECIALTY PAINT OR DIGITAL
GRAPHICS AS NOTED ON SHEET A131. COORDINATE EXACT
GRAPHIC LQCATIQN AND REQUIREMENTS WITH TENANT.
A08 PROVIDE BLOCKING IN WALL FOR TENANT PROVIDED F�AT
SCREEN TV. COORDINATE WITH TENANT FOR EXACT �OCATION.
PROVIDE BLOCKING IN WALL FOR MAGNETIC GLASS BOARD.
A09 REFER TO SHEET A131 FOR EXACT SPECIFICATIONS AND
COORDINATE WITH TENANT ON EXACT LOCATION AND HEIGHT.
A10 PROVIDE ANY ADDITIONAL SUPPORT IN WALL REQUIRED FOR
FLOOR TO CEILING TEXTURED WALL PANE�. REFER TO SHEET A131
FOR TEXTURED WALL PANEL INFORMATION.
A1 1 NOT USED.
CONSTRUCT NEW WAL� AS C�OSE TO EXISTING CO�UMN AS
Al2 POSSIBLE. CONSULT WITN SDI IF COLUMN WRAP GREATLY AFFECTS
DESIGN INTENT AS SHOWN ON PLAN.
PROVIDE NEW BUTT-GLAZED GLASS WINDOW AT CORNER AS
A13 SHOWN. GLASS AND FRAME TO BE ALUMINUM STOREFRONT
SYSTEM TO MATCH NEW FRAMES THROUGHOUT. ALUMINUM TO
HAVE C�EAR ANODIZED FINISH. TOP OF FRAME TO ALIGN WITH
ADJACENT DOOR FRAME. CORNER TO NOT HAVE VERTICAL
FRAME AND TO BE A BUTT SEAM WITN AS MINIMA� GAP AS
POSSIBLE.
P01 PROVIDE POTABLE HOT AND CO�D WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
TENANT TO SUPPORT THEIR OWN HOT WATER NEEDS WITH NO
LANDLORD TIE-IN.
AT SINK, PROVIDE F�OOD STOP TYPE VALVE WITH �EAK
DETECTION.
PROVIDE WATER �INE FOR COFFEE AND REFRIGERATOR. CONFIRM
P02 LOCATION WITH TENANT.
P03 PROVIDE ALL NECESSARY PLUMBING CONNECTIONS FOR
TENANT'S DISHWASHER. SEE E2 ON EQUIPMENT SCHEDULE ON
SHEET A21 1 FOR EXACT REQUIREMENTS.
'
■
AREA NOT IN CONTRACT
AREA OF WORK
ARCHITECTURAL PLAN
0 4' 8' 16'
N
� �
O
N � o �
� � �
c-�—n Z � '�
� ,vi � �
Q` Q t� O
W � � U
O � N
�� �-3
� 3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTE�IECTl1AL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
SSUE
02.02.15 REVIEW SET
02.06.15 STATE SUBMITTAL
03.12.15 A121 UPDATE
03.16.15 A111/A211/E111 NOTES
visoNs
�
PROJECT NUMBER
2014.423
PROJ. MGR DRAWN BY
MJ SS
••�
� • � �
� � ' ' �
�c�i�
NEW OR RELOCATED
�IGHT FIXTURE, 2'x4',
� ���� �ED, DIRECT/INDIRECT
�IGHT FIXTURE, 2'x2',
��� FLUORESCENT.
PARABOLIC
�IGHT FIXTUl2E, 1'x4',
0
F�UORESCENT,
PARABOLIC
�IGNT FIXTURE, 1'x4',
� F�UORESCENT,
INDIRECT
�LIGHT FIXTl1RE,
TRACK
� RECESSED LIGNT FIXTURE
� WALL SCONCE LIGNT
FIXTURE
� LIGHT FIXTURE, PENDANT;
� TECH LIGHTING, OTTO PENDANT
CRYSTA� SATIN NICKE� FINISH
SIZE: 5'-5"H x 5.6"W
INSTALL AT 7'-0" A.F.F. TO BOTTOM OF
FIXTURE; CONFIRM EXACT LOCATION WITH
TENANT
CONTACT: TECN LIGHTING (847-410-4500)
�2 LIGHT FIXTURE, PENDANT;
LSI - ABO�ITE (BD300-10-CW-LED-120-
240-MSV CA 1220 WHITj;
SIZE: 12"H x 13"DIAM
INSTALL AT 10'-6" A.F.F. TO BOTTOM OF FIXTURE
CONTACT: TMS LIGNTING (905-793-1 174)
LIGHT FIXTURE, PENDANT;
� 3 SLIDE
CUPOLE PENDANT (BOW� PENDANT)
FINISN: WHITE
SIZE: 15.7"H x 31.5°DIAM
NOTE: INSTA�� HEIGHTS ARE TO BOTTOM OF FIXTUR
RECEPTION DESK: 8'-0" A.F.F.
WAITING AREA: 8'-0" A.F.F. AND 7'-0"A.F.F. ;
SEE REF�ECTED CEILING PLAN FOR MORE INFO
BREAK ROOM:
BOARD ROOM: 7'-0" A.F.F.
CONTACT: CAN BE PURCHASED AT
ALLMODERN.COM
N� INDICATES NIGHT �IGHT
LOCATION
Q EXIT LIGHT FIXTURE
� EMERGENCY LIGHT
FIXTURE
�N LIGHT SWITCH
�N3 LIGHT SWITCH, 3-WAY
�N4 LIGHT SWITCN, 4-WAY
�ND LIGHT SWITCN, DIMMER
� -" � � LIGHT CIRCUIT
CEI�ING GRID,
SUSPENDED, 2'x4'
CEI�ING GRID,
SUSPENDED, 2'x2'
CEILING GRID,
SUSPENDED, 4'x4' TEES
TO COMP�ETE GRID
GYPSUM BOARD
CEI�ING
° e
a:
OPEN TO DECK CEILING
e, . . a ,
RE�OCATED
DIFFUSER, ROUND
RELOCATED
�� ��� DIFFUSER, LAY-IN, 1'x4'
RELOCATED
DIFFUSER, LAY-IN, 4"x4
� EXHAUST FAN, 2'x2'
EXISTING TO REMAIN
�IGHT FIXTURE, 2'x4',
� F�UORESCENT,
PARABOLIC
��IGHT FIXTURE, 2'x2',
FLUORESCENT.
PARABOLIC
� �IGHT FIXTURE, 1'x4',
F�UORESCENT,
PARABOLIC
�IGHT FIXTURE, 1'x4',
~� F�UORESCENT,
INDIRECT
F��IGHT FIXTURE,
TRACK
� RECESSED LIGHT FIXTURE
� WALL SCONCE LIGHT
FIXTURE
� �IGHT FIXTURE,
PENDANT
NL �NDICATES NIGHT LIGNT
LOCATION
� EXIT LIGHT FIXTURE
� EMERGENCY LIGHT
FIXTURE
� LIGNT SWITCH
�3 �IGHT SWITCH, 3-WAY
�4 �IGNT SWITCH, 4-WAY
�p LIGNT SWITCN, DIMMER
��--�� �IGHT CIRCUIT
-� CEILING GRID,
SUSPENDED, 2'x4'
; -
CEILING GRID,
_ _ SUSPENDED, 2'x2'
CEILING GRID,
SUSPENDED, 4'x4'
GYPSUM BOARD
CEI�ING
r.,__ EXISTING DIFFUSER, lAY-IN,
1 'x4'
EXISTING DIFFUSER, LAY-IN,
4°x4'
� EXISTING EXHAUST FAN,
2'x2'
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND
CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
RE�OCATE DIFFUSERS &
MECHANICAL DIFFUSER RELOCATION
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
EN LARGED C
EILING PLAN
0 2' 4' 8'
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS
REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR
LIGNTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON P�AN ARE FOR REFERENCE ONLY. VERIFY ALL
LOCATIONS OF EMERGENCY EQUIPMENTS AND THERMOSTATS
WITH TENANT PRIOR TO INSTALLATION TO ENSURE THAT NO
FEATURE DESIGN WALLS ARE COMPROMISED. FAILURE TO DO SO
MAY RESULT IN CONTRACTOR HAVING TO RE�OCATE SUCH
EQUIPMENT AT TNEIR OWN EXPENSE.
2. LIGHTING P�ACEMENT AND QUANTITIES ARE FOR REFERENCE
ON�Y. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING
THAT LAY-OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1
STANDARDS. OVER 50% OF THE LIGHTING WI�� BE REP�ACED
WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE
M ET.
3. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE
OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH
ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON
OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH
TNAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS
DETECTED. PROVIDE CEI�ING MOUNTED OCCUPANCY SENSORS
IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTRO�S
(COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED
IF REQUIRED BY CODE.
MECHANICAL NOTES
1. SCOPE INTENT IS FOR EXISTING MECNANICAL SYSTEMS TO
REMAIN.
2. EXISTING F�EX DUCT AND DIFFUSERS BEING RELOCATED AS
NECESSARY PER WA�L LAYOUT. NO MAIN DUCTWORK BEING
RE�OCATED.
3. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR NOTIFYING
APPLICAB�E PARTIES IF ADDITIONAL WORK IS REQUIRED. REFER TO
MECHANICAL NOTES ON SHEET T1 1 1.
R01 CONTROL CORRIDOR AREA LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION. PROVIDE MULTIPLE SWITCNES AS REQUIRED.
COMPLIANCE WITH INDIANA ASHRAE 90.1 ENERGY CODES IS
RESPONSIBILITY OF ELECTRICAL CONTRACTOR AND/OR DESIGN
BUILD CONTRACTOR.
R02 CONTROL BOARD ROOM LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
COMPLIANCE WITN INDIANA ASHRAE 90.1 ENERGY CODES IS
RESPONSIBILITY OF ELECTRICAL CONTRACTOR AND/OR DESIGN
BUILD CONTRACTOR.
R03 CONTROL WAR ROOM LIGHTING WITH 3-WAY SWITCN AT THIS
LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
COMPLIANCE WITN INDIANA ASHRAE 90.1 ENERGY CODES IS
RESPONSIBILITY OF ELECTRICAL CONTRACTOR AND/OR DESIGN
BUILD CONTRACTOR.
R04 PROVIDE NEW DRYWA�L BULKHEAD. BULKHEAD WIDTH TO MATCH
WIDTH OF ADJACENT COLUMN SURROUND. BULKHEAD TO BE 8'-0"
A.F.F. AND EXTEND TO CEILING. CAREFULLY FINISH TRANSITION
FROM THE VERTICAL FACE OF THE DRYWAL� TO THE CEI�ING DECK
SO PAINT LINE BETWEEN THE TWO SURFACES WILL HAVE A
STRAIGHT AND FINISHED APPEARANCE.
INSTAL� FLOATING DRYWA�L CLOUD WITH 6"H DRYWALL EDGE
R05 AROUND PERIMETER. FLOAT CLOUD WITH ALL-THREAD INSTALLED
15" FROM EDGES. PAINT AL� THREAD SAME CO�OR AS CEILING
DECK. INSTAL� MINIMAL QUANTITY OF ALL-THREAD SUPPORTS AS
POSSIBLE. DESIGN INTENT IS TO MAKE ALL -THREAD SUPPORTS AS
VISUALLY UNOBTRUSIVE AS POSSIBLE. IF POSSIBLE, LOCATE FLEX
DUCT TO NEW DIFFUSERS SUCH THAT THEY ARE NOT VISIB�E FROM
GROUND LEVEL SEE PLAN FOR EXACT CLOUD DIMENSIONS.
NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW
C�OUD. FIRE SPRINKLER CONTRACTOR TO PROVIDE SUBMITTA� OF
FINAL LAY-OUT FOR FINA� APPROVAL PRIOR TO INSTALLATION. SEE
CEI�ING FINISH PLAN ON SHEET A131 FOR MORE INFORMATION.
CEI�ING CLOUD TO BE b" DEEP INSTALLED AT 9'-0° A.F.F. SEE PLAN
FOR ADDITIONAL DIMENSIONS. REFERENCE CEILING P�AN ON
A131 FOR FURTHER DIRECTION.
REMOVE AS MUCH OF THE EXPOSED CONDUIT, PIPING, JUNCTION
R06 BOXES AND MISCELLANEOUS UNUSED EQUIPMENT AS POSSIBLE.
C�EAN AND PREPARE FOR DRYFAL� PAINT. AS SPECIFIED, PAINT
EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK,
SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL
BEAMS AND FIREPROOFING WITH DRYFA�� PAINT PER
MANUFACTURER'S RECOMMENDATIONS (P3). CEILING C�OUD TO
BE b" DEEP INSTALLED AT 9'-0" A.F.F. SEE P�AN AND NOTE R05 FOR
ADDITIONAL DIMENSIONS AND INFORMATION. REFERENCE
CEI�ING PLAN ON A131 FOR FURTHER DIRECTION.
PROVIDE NEW 2' X 2' CEILING GRID AND TILE INSTA��ED AS HIGH
R07 AS POSSIBLE. TILE AND GRID TO BE ARMSTRONG'S DUNE BEVELED
EDGE TEGU�AR TILES WITH SUPRAFINE XL 9/16" EXPOSED TEE GRID
SYSTEM.
R08 CEI�ING CLOUD TO HAVE 42"± DIAMETER CUT OUT. SEE PLAN
DIMENSIONS FOR PLACEMENT OF CUT OUT WITHIN CLOUD. VERIFY
FINAL DIMENSIONS WITH TENANT PRIOR TO CONSTRUCTION.
/
� AREA NOT IN CONTRACT
❑ AREA OF WORK
REFLECTED CEILING PLAN
0 4' 8' 16'
N
O �
O
Nd"o �
} � �
cnZ�'�
� ,vi � �
Q` Q t� O
W � � U
O � N
�� �-3
� 3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTE�IECTl1AL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
SSUE
02.02.15 REVIEW SET
02.06.15 STATE SUBMITTAL
03.12.15 A121 UPDATE
03.16.15 A111/A211/E111 NOTES
visoNs
DB IDESCRIPTION
PROJECT NUMBER
2014.423
PROJ. MGR DRAWN BY
MJ SS
1 ST FLOOR
REFLECTED
CEILING PLAN
� �
��z������►'�
CARPET
CPT1 MFG: INTERFACE
TYPE: MODULAR TILE (50CM X 50CM)
PATTERN: A�LITERATION
COLOR: NICKEL/EARTN RUST 9722
INSTALLATION: QUARTER TURNED
VINY� COMPOSITION TI�E
VCT1 MFG: JOHNSONITE
SIZE: 12"xl2"
PATTERN: AZROCK TEXTILE
COLOR: V-287 WOOLLY WOOLLY
INSTALL: QUARTER TURNED
LUXURY VINYL TILE
�VP1 MFG: ARMSTRONG
S I Z E: 4"x48"
PATTERN: ARBOR ART
COLOR: FRUITWOOD NATURAL TP071
NOTE: SEE ARROW ON PLAN FOR PLANK INSTALL DIRECTION
GLASS WA�L TILE
GT1 MFG: VOGUE BAY
SIZE: 6" X 24" MOSAIC SHEET
STY�E: VOGUEBAY G�ASS TILE; CULTURA� BRICK MG25
GROUT: LATICRETE; 44 BRIGHT WNITE
. • . ■
• ■
MFG: JOHNSONITE
VB1 TYPE: 4" VINY� COVE,%8' GAUGE
COLOR: 63 BURNT UMBER
PAINT / WALLCOVERING
P1 MFG: PPG
TYPE: THE MASTER PALETTE
COLOR: ATMOSPHERE
# l OBB 83/006
PPG PAINTS U�TRAHIDE 250 EGGSHE��
PRIMER 1030N PVA WALL PRIMER
FINISH: EGGSHELL
P2 MFG: ZOLATONE (SPECIALITY PAINT)
COLOR: PFX-01030 PEARLTONE
P3 MFG: PPG (CEILING PAINT)
TYPE: THE MASTER PALETTE
COLOR: UNIVERSAL GRAY
#OONN 62/000
PPG PAINTS SPEEDHIDE SUPERTECH
6-726 XI SPRAY DRYFALL F�AT
PPG PAINTS PITTTECH 90-172 DTM PRIMER
FINISH: F�AT
NOTE: PAINT �INE BETWEEN VERTICAL FACE OF
DRYWALL TO TNE CEILING DECK TO HAVE A
STRAIGHT AND FINISHED APPEARANCE
P4 MFG: PPG
TYPE:
COLOR:
FINISH:
P5 MFG: PPG
TYPE:
COLOR:
�
FINISH:
MFG: PPG
TYPE:
COLOR
FINISH:
P� MFG: PPG
TYPE:
COLOR:
FINISH:
THE MASTER PALETTE
MOROCCAN SANDS
#OIYY 36/694
PPG PAINTS b-70 SPEEDHIDE LATEX FLAT
PPG PAINTS b-2 SPPEDHIDE PRIMER SEALER
F�AT
THE MASTER PALETTE
SCOTTISH WALTZ
#30GY 27/514
PPG PAINTS b-70 SPEEDHIDE LATEX FLAT
PPG PAINTS b-2 SPPEDHIDE PRIMER SEALER
F�AT
THE MASTER PALETTE
BESIDE THE OCEAN
#70BG 40/284
PPG PAINTS b-70 SPEEDHIDE LATEX FLAT
PPG PAINTS b-2 SPPEDHIDE PRIMER SEALER
F�AT
THE MASTER PALETTE
O�D WORLD BLUE
#10BB 09/155
PPG PAINTS b-70 SPEEDHIDE LATEX FLAT
PPG PAINTS b-2 SPPEDHIDE PRIMER SEALER
F�AT
P$ MFG: PPG
TYPE: THE MASTER PALETTE
COLOR: O�D WORLD BLUE
#IOBB 09/155
PPG PAINTS ULTRAHIDE 250 EGGSHELL
PRIMER 130N PVA WALL PRIMER
FINISH: EGGSNELL
P�ASTIC LAMINATE / SO�ID SURFACE
PL1 MFG: SURFACE MATERIALS (LAB DESIGNS)
STYLE: ABSTRACT
COLOR: L-1 1519 FOG DIFFUSION
PL2 MFG: SURFACE MATERIA�S (LAB DESIGNS)
STYLE: SO�ID COLOR
COLOR: L-11520 WHITE: LWEN FINISH
SS1 MFG: CORIAN
COLOR: WHITE JASMINE
THICKNESS: 1 /2" THICK
QZ� MFG: ZODIAQ
COLOR: CLOUD WHITE 2 CM - 3CM
�Q►'����i�
MFG: PULP STUDIOS
GL1 PATTERN: PINTURA GLASS MARKER AND MAGBOARD
COLOR: WHITE Ob
SIZE: b'X8'
NOTE: COORDINATE WITH TENANT ON EXACT HEIGHT
AND �OCATION.
OMFG: INTERLAM, INC.
TP1 PATTERN: ART DIFFUSION SOT002
COLOR: S WHITE HG
�)
INSTALL: VERTICAL PATTERN DIRECTION
NOTE: PANELS TO EXTEND FULL HEIGHT AND WIDTH
OF WALL. COORDINATE FINAL LAYOUT WITH
MANUFACTURER PRIOR TO ORDER. MUST BE
INSTA��ED BY CERTIFIED INSTA��ER.
� � �
F01 EXISTING FINISHES TO REMAIN. NEW DRYWALL CEILING CLOUD TO BE PAINTED P1 WITH P6 PLASTIC LAMINATE PANEL WITN APPROPRIATE SUBSTRATE. AT PROVIDE ZINC TERRAllO STRIP AT LVT TO CARPET TRANSITION.
O F05 ACCENT BORDER ON ALL 4 EXPOSED VERTICA� SIDES. Pb ACCENT F09 SEAMS, UNDERLAP SUCH THAT SURFACE APPEARS CONTINUOUS. F13 PROVIDE LEVE�ING LATEX UNDER CARPET AS SUCH THAT TOP OF
O O O
F02 NEW DRYWALL CEI�ING CLOUD TO BE PAINTED P1 WITH P7 BORDER TO BEGIN AT BOTTOM EDGE OF SIDES AND EXTEND TOP CAP TO BE SS1, 1" DEEP BY WIDTH OF ADJACENT WALL. TOP CARPET PILE IS LEVEL WITH TOP OF PLANK. SEAM SEA� CARPET
ACCENT BORDER ON AL� EXPOSED SIDES. P7 ACCENT BORDER TO UPWARDS 1". THE REMAINING 5" OF THE EDGE TO BE PAINTED Pl . OF WALL CAP TO BE AT 3'-6". PROVIDE HORIZONTAL ANODIZED EDGES. ZINC TERRAllO STRIP MUST BE LEVEL WITH OR SLIGHT�Y
BEGIN AT BOTTOM EDGE OF SIDES AND EXTEND UPWARDS 1". THE COORDINATE WITH TENANT FOR RECOMMENDATIONS FOR ALUMINUM REVEA� BETWEEN TOP OF PANE� AND TOP CAP AS HIGHER THAN THE P�ANK EDGE. TRANSITION PROFILE MUST BE
REMAINING 5" OF THE EDGE TO BE PAINTED P1. CEILING FINISH TO ALLOW FOR SMOOTH APPLICATION OF SHOWN IN DETAIL. P�ASTIC LAMINATE TO BE RAILROADED SUCH APPROPRIATE FOR FLOORING MATERIALS AND MUST BE SUBMITTED
INTENDED SPECIALTY PAINT OR DIGITAL GRAPHICS. COORDINATE THAT LINEAR PATTERN RUNS HORIZONTALLY. TO SDI FOR FINAL APPROVAL PRIOR TO INSTAL�ATION.
NEW DRYWALL CEI�ING CLOUD TO BE PAINTED Pl WITH P4 EXACT GRAPHIC LOCATION WITH TENANT.
F03 ACCENT BORDER ON A�L 4 EXPOSED VERTICAL SIDES. P4 ACCENT
BORDER TO BEGIN AT BOTTOM EDGE OF SIDES AND EXTEND
UPWARDS 1". THE REMAINING 5" OF THE EDGE TO BE PAINTED P1.
COORDINATE WITH TENANT FOR RECOMMENDATIONS FOR
CEILING FINISH TO ALLOW FOR SMOOTH APP�ICATION OF
INTENDED SPECIALTY PAINT OR DIGITA� GRAPHICS. COORDINATE
EXACT GRAPHIC LOCATION WITH TENANT.
NEW DRYWALL CEI�ING CLOUD TO BE PAINTED P1 WITH P5
F04 ACCENT BORDER ON A�L 4 EXPOSED VERTICAL SIDES. P5 ACCENT
BORDER TO BEGIN AT BOTTOM EDGE OF SIDES AND EXTEND
UPWARDS 1". THE REMAINING 5" OF THE EDGE TO BE PAINTED P1.
COORDINATE WITH TENANT FOR RECOMMENDATIONS FOR
CEILING FIMSH TO ALLOW FOR SMOOTH APP�ICATION OF
INTENDED SPECIALTY PAINT OR DIGITA� GRAPHICS. COORDINATE
EXACT GRAPHIC LOCATION WITH TENANT.
F06 PROVIDE JOHNSONITE SLIMLINE TRANSITION STRIP AT CARPET TO
VCT OR CONCRETE TRANSITION. (COLOR TBD.) VERIFY
TRANSITION STRIP PROFILE IS APPROPRIATE FOR HEIGNT OF
SPECIFIED FINISHES.
AREA TO RECEIVE APPLIED DIGITAL GRAPNIC OR DIMENSIONAL
F07 EPVC. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH
TENANT.
PROVIDE NEW AREA RUG USING CPTI . ATTACH (42) INDIVIDUAL
F10 TILES TIGHTLY TO ONE ANOTHER ON BACKSIDE USING INTERFACE
TAC-TILE ADHESIVE STRIPS PER MANUFACTURER'S
RECOMMENDATION. FINAL RUG SIZE TO BE 6 TILES BY 7 TILES AND
APPROXIMATE�Y 9'-8" X 1 1'-b". EDGES DO NOT NEED BAND.
F1 1 PROVIDE VERTICAL FRY REGLET REVEA� AT TRANSITION FROM
PLASTIC LAMINATE TO DRYWALL. DESIGN INTENT IS FOR REVEA� TO
MATCN "F" REVEA�. 5/8" DEEP X 1/2" WIDE, BUT CONTRACTOR IS
RESPONSIBLE FOR SELECTING MOST APPROPRIATE PROFI�E FOR
THIS APPLICATION.
F08 P�ASTIC LAMINATE PANE� WITH APPROPRIATE SUBSTRATE. AT
SEAMS, UNDER�AP SUCH THAT SURFACE APPEARS CONTINUOUS. PROVIDE MOSAIC GLASS BACK SPLASH (GT1 j BETWEEN TOP OF
PATTERN TO BE RAILROADED SUCH THAT STRIPE PATTERN RUNS F12 COUNTER AND BOTTOM OF UPPER CABINETS. SEE SNEET A212 FOR
HQRIZONTALLY. EXACT LOCATION.
GENERAL NOTES
1. REFERENCE ELEVATIONS OF CASEWORK FOR BASE MATERIALS.
BASE ON CASEWORK DOES NOT NECESSARI�Y MATCH VINYL BASE
ON ADJACENT WALL.
CEILING FINISH PLAN
0 4' 8' 16'
� AREA NOT IN CONTRACT
❑ AREA OF WORK
FINISH PLAN
0 4' 8' 16'
N
� �
O
N � o �
� � �
c-�—n Z � '�
� ,vi � �
Q` Q t� O
W � � U
O � N
�� �-3
� 3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTE�IECTl1AL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
SSUE
02.02.15 REVIEW SET
02.06.15 STATE SUBMITTAL
03.12.15 A121 UPDATE
03.16.15 A111/A211/E111 NOTES
visoNs
�
PROJECT NUMBER
2014.423
N
PROJ. MGR DRAWN BY
MJ SS
••�
. ,
_ TOEXISTING GENERAL CASEWORK NOTES D40R SCHEDULE
� STACK
,y2�v. � , DOORS . FRAME 'HARDWARE'
r�'' 1. MILLWORKER TO PROVIDE SUBMITTAL FOR PROPOSED SEAMING OF NUM. DIMENSIONS REMARKS
� I TYPE MATERIAL FINISH TYPE MATERIAL FINISH SET
c��. � � ( P�ASTIC LAMINATES, QUARTZ AND SOLID SURFACE PRIOR TO
�I=' � ORDERING MATERIALS. 3 nnoHAwK ' , ,
� 1� 3'-0"x8'-0"x1 /4' (PAIR) p2 ROTaRvsiRCH SEE REMARK F4 SEE REMARK SEE REMARK E�, CL, PP Rl Rl . PROVIDE NEW FUL� HEIGHT DOUB�E WOOD DOORS WITH FU�� FLUSH
� � � � J SEl ECT WHITE �
NEw 2�" DEEP, 4.5° THICK BEAD LITE KITS AND SIDELITES ON EITHER SIDE WITH 4" SQUARE WOOD
I ( SO�ID SURFACE fSSI) CAS EW O R K N OTES ALUMINUM CLEAR ALUMINUM CLEAR
1� ' 3'-0"x8'-0"xl3/4' D3 F3 C�, PP FRAME. LOBBY SIDE OF DOOR AND FRAME TO BE STAINED TO MATCH o �
� ( couNrER ENCAsiN� ' STOREFRONT ' ANODIZED ' ' STOREFRONT ' ANODIZED ' d- 0
TENANr's REFRi�ERAroR; BUI�DING STANDARD IN LOBBY. DOOR AND FRAME ON TENANT'S SIDE � N
02 3'-0"x8'-0"xl3/4' ' D3 ; ALUMINUM CLEAR F2 ALUMINUM C�EAR OL, CH 43 `o p U
I -� � so�i� suRFACE couNrER O TO HAVE CLEAR FINISH. DOOR HARDWARE TO BE ROCKWOOD'S p�
' STOREFRONT ' ANODIZED ' ' STOREFRONT ' ANODIZED ' , N �I' �
� ��, ( CLG. TO EXTEND 3° PAST BASE 1. PROVIDE A.W.I. CUSTOM GRADE, FLUSH-OVERLAY CABINETS. O 3 ALUMINUM CLEAR ALUMINUM C�EAR MEZZOTEK WITHOUT GRIP ZONE (RM2120, 1-1 /2" DIA, 20" CTC.
��"�• CABINETS. NO &ACK SP�ASH 03 3�-O��XH�-O��XI �4 � D3 F2 OL, CH N z���
( ' STOREFRONT ' ANODIZED ' ' STOREFRONT ' ANODIZED ' COORDINATE WITH TENANT IF BACK UP MANUA� LOCK IS DESIRED. IF —� �
I OR SIDE SP�ASHES. SCRIBE HEIGHT OF OPENING IS FABRICATE WITH PLASTIC �AMINATE (PL1) COVERED M.D.O. � N��
ALUMINUM CLEAR ALUMINUM C�EAR SO, PROVIDE SUBMITTALS TO SDI AND TENANT FOR REVIEW.
� ( saCK oF suRFaCE to wa�� 3a t/2° aEaR; vERiFv BOARD WITH CKP BRAND PREMIUM SERIES STAINLESS STEEL BAR 04 3'-0"x8'-0"xl3/4' D3 F2 OL, CH �— t'? -'�
AT TRANSITION FROM BACK F I N A L H E I G H T P R I O R T O STOREFRONT ' ANODIZED STOREFRONT ' ANODIZED � �(� O
( P U L L # 8 0 0 0- 1 2 8 M M C O O R D I N A T E W I T H E L E V A T I O N S F O R
� OF COUNTER TO WALL FagRicarioN ( �� 3„ ALUMINUM CLEAR ALUMINUM C�EAR R2. PROVIDE PAIR OF 3' 2" X 8'-3" ± SLIDING GLASS DOORS (CLEAR w Q��
I �EXIST QUANTITIES AND DIRECTION OF LAMINATE GRAIN (HORIZONTA� AS 05 3'-0"x8'-0"xl /4 D3 STOREFRONT ANODIZED ' F2 STOREFRONT ANODIZED OL, CH ANODIZED ALUMINUM STOREFRONT STYLE) ON TRACK. TRACK TO BE p�� N
a°v. NEw 25�� DEEP PLASTIC INDICATED BY ARROWS ON ELEVATIONS): �� '
SiNK ( LAMINATE (PLl) COUNTERTOP 24" DEEP COUNTERTOPS, 23" DEEP BASE CABINETS, 12" DEEP 06 3'-0"x8'-0"xl3/4' ' D3 ' ALUMINUM CLEAR F2 ALUMINUM C�EAR OL, CH MOUNTED ABOVE FRAME; CONTRACTOR TO VERIFY PROPER DOOR d- ._ Q 3
2"�'• ( NO gaCK SP�aSH oR Si�E : ' STOREFRONT ' ANODIZED ' STOREFRONT ANODIZED SIZE FOR CONNECTION TO TRACK SO THAT DOOR REACHES WITHIN � 3
SPLASHES. SCRIBE BACK OF �� UPPER CABINETS. ALUMINUM CLEAR ALUMINUM C�EAR � 3
�.�. ( NOTE: REFER TO FLOORPLAN 07 3'-0"x8'-0"xl3/4' D3 F2 OL, CH 1/2" OF FINISHED FLOOR. OUTSIDE EDGE OF DOORS TO ALIGN WITH
SURFACETO WALLAT INSIDE EDGE OF SIDE�IGHT FRAME WHEN DOORS ARE IN CLOSED
aN� casEwoRK E�EvarioNs STOREFRONT ' ANODIZED ' ' STOREFRONT ' ANODIZED '
( FOR SINK �OCATIONS. TRANSITION FROM BACK OF 2. PROVIDE A.W.I. CUSTOM GRADE, FLUSH-OVERLAY CABINETS. ALUMINUM CLEAR ALUMINUM C�EAR
� ( couNTER ro wa��. �'�� ��`, u.c. �� ���� FABRICATE WITH P�ASTIC LAMINATE PL1 COVERED M.D.O. BOARD 08 � 3'-0"x8'-0"xl3/�" �� D3 � � � F2 � � � OL, CH POSITION. CONTRACTOR TO PROVIDE SUBMITTAL OF TRACK TO MATCH
� �� % �� �� � FRi�GE BY ���� �� �., STOREFRON DIZE STOREFRON DIZE C�EAR ANODIZED FINISH AS C�OSELY AS POSSIB�E. DOOR PULLS TO BE
t ) T'� ANO D'� T' ANO D'
����, , ( �� � ' � WITH CKP BRAND PREMIUM SERIES STAINLESS STEEL BAR PULL �� ALUMINUM �� CLEAR �� ALUMINUM �� C�EAR
NEw aasE caawEls � - -- __- � rENANT; � �- ___ _���- 09 3'-0"x8'-0"xl3/4' �� D3 �� � � F2 � � � OL, CH � ROCKWOOD'S MEZZOTEK WITHOUT GRIP ZONE (RM2120, 1-1 /2" DIA, 20"
(: ' (sEE casEwoRK uo1E 2) - �R �N SEE El ON GR iN (#8000-128MMj. COORDINATE WITH E�EVATIONS FOR QUANTITIES. STOREFRONT ' ANODIZED ' ' STOREFRONT ' ANODIZED ' CTC ON INSIDE AND OUTSIDE OF ROOM TOTA� OF 4 PULLS . PROVIDE
2"W• EQu�P�`r'ENT DIRECTION OF LAMINATE GRAIN HORIZONTAL AS INDICATED BY Mo"AwK ALUMINUM CLEAR � �
����.�. F���ER pANE�As NEEpEp; sct�Eou�E � 1� 3'-0"x8'-0"xl3/�" � Dl � ROTaRvsiRCH C�EAR � Fl � � � S� STOPPER ON INSIDE FACE OF TRACK SUCH THAT DOOR PULL DOES NOT
� ' � ' ARROWS ON ELEVATIONS): se�ecrwHirE � STOREFRONT ' ANODIZED
gorH si�Es �� �� HIT FRAME WNEN IN FULLY OPEN POSITION. +
2"`�'� 25" DEEP COUNTERTOPS, 24" DEEP BASE CABINETS, 12" DEEP � 3„ ALUMINUM CLEAR ALUMINUM CLEAR
BASE TO BE PLl TO MATCH l,� l�� 11 3�-���XB�-���Xl �4 D3 Fl P$
ExisT To � E�Q• 42-� � 2'-0" 42-� � E.Q. � UPPER CABINETS. STOREFRONT ANODIZED STOREFRONT ANODIZED R 3. Q O O R A N D F R A M E T O M A T C H B U I L D I N G S T A N D A R D O N C O R R I D O R T H I S D R A W I N G, A N D T H E I D E A S,
4„ W CABINETS; GRAIN DIRECTION TO � A L U M I N U M C L E A R A L U M I N U M C L E A R
BUII.DING MATCH CABINETS HO�D 1 1 3'-O"x8'-0"xl3�q" � D3 � � Fl � � � PS SIDE. �DESIGNS AND CONCEPTS CONTAINED
�RAw � STOREFRONT �� ANODIZED � � STOREFRONT �� ANODIZED � HEREIN, ARE THE EXC�USIVE
� RISER DIAGRAM 2 ELEVATION - RECEPTION 101 COFFEE EQUIPMENT SCHEDULE ,5 ���� 3�-o��Xs�-o��X,3,4�,PA,R, ��� 04 � A��M�N�M � ��EAR �� Fs � A��M�N�M � ��EAR PP �� Rz
� STOREFRONT ' ANODIZED �� ' STOREFRONT ' ANODIZED R4. PAINT EXISTING METAL DOOR AND FRAME TO MATCH ADJACENT WA��. ; INTE��ECTt1AL PROPERTY OF SCHOTT
'' ' ` nnoHAwK ALUMINUM CLEAR DESIGN, INC., AND ARE NOT TO BE
A21 1 TYPICA� A�� SINGLE LOCATIONS A21 1 0 1' 2' 4' E1: COFFEE BAR UNDER COUNTER REFRIGERATOR: 15 3'-0"x8'-0"xl3/4' Dl Ro� crwHrE C�EAR Fl STOREFRONT ANODIZED PS USED OR REPRODUCED IN WHO�E, OR
MAGIC CHEF - MODEL #MCWBC77DZC MONAwK ALUMINUM CLEAR IN PART, WITHOUT THE WRITTEN
16 BOTTLE/77 CAN DUAL-ZONE WINE AND BEVERAGE COOLER 16 3'-0"x8'-0"xl3/4' Dl RorARv aiRCH C�EAR Fl SL, ES, CL, CR R3 CONSENT OF SCHOTT DESIGN.
e�ecTwHirE ' STOREFRONT ANODIZED
17 � EXISTING � -- � -- � -- � -- �� -- -- � -- � R4 �� �
E2: BREAK ROOM REFRIGERATOR:
2�-0° FRIGIDAIRE - MODEL #FFTR 1821 QS
���� 18 CU.FT. TOP FREEZER REFRIGERATOR IN STAINLESS STEEL
E3: BREAKROOMMICROWAVE DOOR/FRAME NOTES HARDWARE LEGEND �
FRIGIDAIRE - MODEL #FFCT1278LS �
b ' COUNTERTOP MICROWAVE WITH CONVECTION IN STAINLESS STEEL W
2�'0'" 1. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE W
A2� � E4: BREAK ROOM DISHWASHER CL CLOSER �
PROVIDE NEW BUI�DING STANDARD DOORS MATCHING SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL
NEw i°THICK PLASTIC GE BUI�T-IN WITH HIDDEN CONTROLS, G�DT69bDSS, EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO ACCESS CONTROL�ED ELECTRONIC AND/OR MAGNETIC CH COAT HOOK �
N 4 3'-6�� >> CR CARD READER BY TENANT N.I.C.
A2>> �anniNATE (P�t) PaNE� 32 32' NIGN, STAINLESS STEEL. MATCH EXISTING. PRE-MACHINE NEW DOORS FOR HARDWARE AND ASSOCIATED DEVICES. ALL � �
�'-o' DB DEADBOLT � vi
CY�INDRICAL LOCKSETS. SPECIFICATIONS AND INSTALLATIONS MUST COMPLY DL DUMMY �EVER NM
�° QuaR7z (Qzt) aCCEN7 WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS EL ELECTROMAGNETIC �OCK PER IBC 2012
�' � � COUNTER TOP 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW OF EGRESS. ( ) J Z`- J
� � A211 DOORS. REUSE EXISTING HARDWARE ON EXISTING ES ELECTRIC STRIKE BY TENANT (N.I.C.) � Q
n' . o � VERTICAL FACE OF DESK TO BE H HOLD OPEN �
P�asric �aMwaTE �P��i; DOORS WHERE POSSIB�E. FOR NEW DOOR HARDWARE, 7. PROVIDE BUTT HINGES ON A�� DOORS AS FOL�OWS: ; ��
W = - �RaiN �iREcrioN ro aE PROVIDE BUILDING STANDARD, GRADE 2 MINIMUM. • 7'-0" HT. TO HAVE 3 HINGES KP KICK PLATE Q�
- 3'-6" �RAiN HORizoNTa� PROVIDE A.D.A. ACCESSIB�E �EVER HANDLES ON NEW • GREATER THAN 7'-0' IN HT. TO HAVE 4 HINGES KS KICK STOP ��
��-o" N i/a" HIGN X 1/2" DEEP SELF REVEA LOCK AND LATCHSETS. • FIMSH TO MATCH HARDWARE SET OL OFFICE LOCKSET � � 7
PH PANIC HARDWARE � W L
a° PLASTIC LAMINATE (PL1) BASE 3. PROVIDE NEW BUILDING STANDARD FRAMES AS 8. PROVIDE 1 SET OF SILENCERS ON ALL DOOR FRAMES PL PRIVACY LOCKSET
AT SAME P�ANE AS UPPER �� PP PUSN/PULL �
5 12, o„ PORTION; GRAIN DIRECTION TO REQUIRED. REUSE EXISTING FROM DEMO�ITION WHERE UN�ESS OTHERWISE NOTED. PS PASSAGE LATCHSET �
A211 MATCH PLl PANEL ABOVE POSSIBLE. �
9. PROVIDE WAL� STOP (FLOOR STOP WHERE APP�ICAB�E) PV PIVOT HINGE i /IC� W
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE RL ROLLER LATCHES �
3 P LA N— R E C E PTI O N 4 E L E VATI O N— R E C E PTI O N 101 D ES K ADJACENT WA�L CORNERS UNLESS OTHERWISE NOTED WOOD BLOCKING BEHIND WALL STOP. SL STOREROOM LOCKSET W I� �
ON PLAN. TS TOP STRIKES /I� ��
A21 1� O� D ES K 0 2' 4' 8' A21 1 � �� 2� 4� 10. �ESSEE MUST TAKE ALL PROPER STEPS TO PROTECT o�
5. REFER TO TENANT AND LANDLORD FOR KEYING EXISTING FINISNES AT TNE PROPERTY INCLUDING, BUT �
PLASTIC �AMINATE (PL1) REQUIREMENTS AND LOCKSETS. NOT �IMITED TO, THOSE IN THE �OBBY AND CORRIDORS. ( �
FI�E CABINETS WITH 2
`.�
FILE DRAWERS WITH � ,�
SLIDES AND FILE �� O R/ F RAM E TY P ES
HANGER PROYIDE P�ASTIC LAMINATE (PL1 J FINISH Q�
LOCKS ON DRAWERS
AND PU�IS AS WIRE MANAGEMENTTRAY; �
INDICATED (SEE EXACT STYLE AND LOCATION 1" DEEP, 12" WIDE 4UARTZ II� N
NEW 1" THICK PLASTIC 3-b CASEWORK NOTE 2} Tg� (QZ1) TRANSACTION TOP
1�
LAMINATE (PL1) PANEL 10�-0�� 4�-10�� 5-2�� 3�-4° j �
---- QUARTZ (QZI� FINISH
o� 2' 1'-8" 2„ 6, 0„ 2, �,_8„ 2„ 2„ 3, 0„ 2, �, 4„ 2„ 2„ 3, �„ 2, �,_8„ 2„ 2„ 3, �„ 2, �
CONDUIT FROM WALL TO
SERVICE PANEL MOUNTED NEW 24" DEEP PLASTIC
QUARTZ (QZl ) PANEL AND o DATA AND ELECTRICAL 3�� LAMINATE (PL1 � WORK � — � � �
COUNTER r> GRAIN SURFACE; PROVIDE 2 c� N c� c�
o PLASTIC GROMMETS IN
VERTICAL FACE OF DESK TO BE - GRAIN _ WORK SURFACE, EXACT �„
3' °� COLOR AND LOCATION TO Ya" TEMPERED /a TEMPERED Ya" TEMPERED
PLASTIC LAMINATE (PL1) GLASS G�ASS GLASS WITH '
OPEN STORAGE; PLASTIC BE DETERMINED � � VINYL FILM �SSUE
1/4" HIGH X 1/2" DEEP SELF REVEAL � LAMINATE (PL1) FINISH ON ALL ` GRPHIC � `
suRFacEs (sEE casEwoRK -- -- - � � � _ � , �� � `��, �`� - _ - _ - _ DATE � �� DESCRIPTION��
PLASTIC �AMINATE (PL1) SIDE
4" PLASTIC LAMINATE (PL1) BASE NOTE 2) o GRAIN PANEL � � � � -��' � -��' � -��' � OZ.OZ.� S REVIEW SET
AT SAME PLANE AS UPPER �-� '- � e GRAW GRAW �
PORrioN; �RaiN �iRECTioN To � N � i 02.06.15 STATE SUBMITTAL
MATCN PLl PANEL ABOVE GRAIN 1/4" HIGH X 1/2" DEEP SELF REVEAL i 03.12.15 A121 UPDATE
GRAIN
4" PLASTIC LAMINATE (PL1) BASE � ` � ; 03.16.15 Al l l/A211/E111 NOTES
s ELEVATION RECEPTION 101 DESK ArsAMEP�A"EAs�PPER
� 3'-0" 1'-3" PORTION; GRAIN DIRECTION TO
MATCH PLl PANEL ABOVE
A211 0 �' �' 4' �REVIsoNs
6 E L E VATI O N- R E C E PTI O N 101 D ES K �,AR oATE ���� oB oEs�R�PT�oN ����
az> > o,� r a� F4 F3 F2 F 1 ; ..._ ...................................�__ .....--
, 2�-s��
4' 2'-8° �--4�� 6�-0° 4'1 2'-8" „ 3'-2" � � � �
1"THICK, 12" WIDE QUARTZ (QZI) 4" CLEAR
TRANSACTION TOP 4" CLEAR
QUARTZ (QZl ) FINISH � %a" TEMPERED �ANODNUM ANODIZED �
GLASS WITH TRIM ALUMINUM
VINYL FILM TRIM Ya" TEMPERED
GRPHIC GLASS
PLASTIC LAMINATE (PL1 � FINISH
24" WIDE PLASTIC LAMINATE � 4" WOOD
GRAIN FRAME, - - - -
(PLi) WORKSURFACE - - �'? o 0 0
� �
WIRE MANAGEMENT TRY; N � � STAINED TO �
EXACT STYLE AND PLASTIC LAMINATE (PL1) FI�E � � � MATCH °� � CO
LOCATION TBD CABINETS WITH 2 BOX `:� BUILDWG
DRAWERS AND 1 FILE DRAWER STANDARD ON G4LASS WTH G4LA S WITH
� � � LOBBY SIDE VINYL FILM VINYL FILM j
; GRAW GRAIN WITH SLIDES AND FILE HANGER, � AND MATCH GRPHIC GRPHIC =
��_g� PROVIDE �OCKS AND PULLS AS TENANT FINISH o
PLASTIC �AMINATE (PL1) GRAI (NDICATED
PENCIL DRAWER ~ � -
ON TENANT
GRAW GRAIN SIDE
4° PLASTIC LAMINATE �PLI ) BASE � �I-�
AT SAME PLANE AS UPPER I�
PROJECT NUMBER
PORTION; GRAIN DIRECTION TO F5 D4, D3 D2 D 1 20� 4.423
��-3�� ��� MATCHPLi PANELABOVE
7
ELEVATION — RECEPTI4N 101 DESK PRo�nn�R oRawN eY
A21 1 0 1' 2' 4'
1 ST FLOOR
DOOR SCHEDULE
INTERIOR DETAILS
EQUIPMENT SCHEDULE
E1: COFFEE BAR UNDER COUNTER REFRIGERATOR:
MAGIC CHEF — MODEL #MCWBC77DZC
16 BOTTLE/77 CAN DUAL—ZONE WINE AND BEVERAGE COOLER
E2: BREAK ROOM REFRIGERATOR:
FRIGIDAIRE — MODEL #FFTR 1821 QS
18 CU.FT. TOP FREEZER REFRIGERATOR IN STAIN�ESS STEE�
E3: BREAK ROOM MICROWAVE
FRIGIDAIRE — MODEL #FFCT1278LS
COUNTERTOP MICROWAVE WITH CONVECTION IN STAINLESS STEEL
E4: BREAK ROOM DISHWASHER
GE BUILT—IN WITH HIDDEN CONTROLS, GLDT696DSS,
32 32' HIGN, STAINLESS STEEL.
1'-6"
NEW PLASTIC LAMINATE
(PL2) WA�L CABINETS
(SEE CASEWORK NOTE 2)
NEW 2' DEEP PLASTIC
LAMINATE (PL1 � PANTRY
STYLE CABINET WITH ROD
AND SHELF (SEE DETAIL
9/A212) PROVIDE
UPGRADED PULLS LISTED
IN CASEWORK NOTE 2
NEW 25" DEEP SOLID
SURFACE (SSl)
COUNTERTOP, WITH 4"
BACKSPLASH
NEW P�ASTIC LAMINATE
(PL1) BASE CABINETS,
(SEE CASEWORK NOTE 2)
VB1 BASE
� � �
. , ,� ,
0 1' 2' 4'
PLASTIC LAMINATE (PLl ) SHELF
SUPPORTS (TYP. EACN END)
ly" DIA. ROD
NOTE: WHERESPAN
EXCEEDS 4`-0", PROVIDE A
CENTER SUPPORT BRACKET.
NOTE: PROVIDE (2)
BRUSHED CHROME DOUB�E
COAT HOOKS AT MAXIMUM
48" A.F.F. FOR ADA
COMP( IANCE.
AT D DETA L
9 CO /RC� I
A212 0 3" 6" 1' 2'
FILLER PANEL AS NEEDED
NEW PLASTIC LAMINATE
(PL2) WALL CABINETS
(SEE CASEWORK NOTE 2)
GLASS MOSAIC
BLACKSPLASH (GTl )
33°x21"STAINLESS STEEL
DOUBLE BOWL SINK, WITH GARBAGE
DISPOSAL; FAUCET TO BE DANZE'S
AMALFI SINGLE HANDLE KITCHEN
FAUCET IN STAILNESS STEEL,
MODEI #D409030SS
NEW 24" DEEP SOLID SURFACE (SSl )
COUNTERTOP, NO BACKSPLASH;
SCRIBE BACK OF SURFACE TO WALL
AND SEAL TRANSITION WITH CLEAR
SILICONE SEALANT
NEW BASE CABINETS ,
(SEE CASEWORK NOTE 2)
VB1
3
A212
2'-6"
(V
4 � 4
A212 A212
3
A212
2 PLA� - WORK 114
A212 �S �A N D 0 1' 2' 4'
1'-9" . 2'-9"
2'-9" . 2'-9"
2'-6"
NEW 2'-6" DEEP SOLID
SURFACE (SSl)
COUNTERTOP
NEW PLASTIC LAMINATE
(PL1) BASE CABINETS
(SEE CASEWORK NOTE 2)
2'-9„
VB1
P7
114 I S �A N D°,� 2� 4�
- - - - -. y' . _ . .. ... .
� - . - -� �- -- � - - — - REFRIG�BY �
- - - - -- -- - - - - - - �� TENA T;
���) �,) �,� � ( I �,' �`�i I,'� � � seE e2 oN
I EQUIPMENT I
� �� SCHEDULE �
, _,
- r - -- �- �- � T===�' _=- � � — — — — �
- — - ,_ _
�
. '— ' --` •— 'I I
� _ -- II� I
�� `' _ � 00 '= =� � I I I
�; �
� DISHWASNER �I I
\\ I I _ I I _ _ I�— -- TENANT; ���� II I
�� �., GRAIN� � SEE E4 ON �I I
\
EQUIPMENT
�� ;; SCHEDULE �L — — — — �
� 2'-6" � 2'-6" � 2'-9" � 2'-0" � 1'-3" � 3'-0"
0 1' 2' 4'
(V �
2° X 4" WOOD
BLOCKING
PLASTIC LAMINATE (PL1)
WITH APPROPRIATE
SUBSTRATE.ATSEAMS, M
UNDERLAPSUBSTRATE
SUCH THAT SURFACE_
APPEARS TO BE
CONTINUOUS
NEW 2'-6" DEEP SOLID
SURFACE (SS1)
COUNTERTOP
NEW PLASTIC LAMINATE
(P�l ) BASE CABINETS
(SEE CASEWORK NOTE 2)
PLASTIC LAMINATE (PL1)
OPEN SHELVING
� 2 -9 �
114 I S LA N D°,� 2� 4�
I
�
1" DEEP SOLID SURFACE
(SS 1) COUNTER TOP;
WIDTN VARIES, SEE
DETAIL 5/A212 FOR
DIMENSIONS /
!� �0����I �O� 11�
� 1�
I •
2�_�" I. 7_6�
2�_b�
SHORTEN EXTENSION OF
DRAWER AND SNORTEN
DEPTH OF DRAWER SUCH
THAT FULL EXTENSION
DOESN'T HIT PULL OF
ADJACENT DRAWER.
SHOW FINAL
CONFIGURATION IN
SHOP DRAWINGS FOR
FINAL APPROVAL
SOLID SURFACE (SS 1)
ON VERTICAL PANEL
NEW PLASTIC LAMINATE
(PLi) BASE CABWET (SEE
CASEWORK NOTE 1)
FILLER PANEL AS
NEEDED; BOTN SIDES
VB1
0 1' 2' 3'
NEW 19" DEEP, 1" THICK
SOLID SURFACE (SSl )
COUNTER TOP
NEW 24" DEEP SOLID
SURFACE (SS i )
COUNTERTOP WITN 7"
HIGH BACKSPLASH
FILLER PANEL AS NEEDED;
BOTH SIDES
NEW PLASTIC LAMINATE
(PLi ) BASE CABINETS
(SEE CASEWORK NOTE 1 j
vat
SO�ID SURFACE SS1
NEW 12" DEEP, 1"THICK
SOUD SURFACE (SSl ) -
COUNTER TOP
■�������
�
�� ���
��
8�,
0 1' 2' 4'
O �
O
N � � �
� � �
-�--
v> Z '�
— t� N
� ,vi � �
�` Q t� O
W � <'`� U
O � N
�� �-3
� 3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTE�IECTl1AL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
SSUE
02.02.15 REVIEW SET
02.06.15 STATE SUBMITTAL
03.12.15 A121 UPDATE
03.16.15 A111/A211/E111 NOTES
visoNs
DB IDESCRIPTION
PROJECT NUMBER
2014.423
PROJ. MGR DRAWN BY
MJ SS
1 ST FLOOR
�c�i�
I�I_��i��•�•]►��R•�c•7���:���I.c�•l;Z�,T,r_���'
� POWER OUTLET, DUP�EX
�POWER OUTLET,
QUADRUPLEX
� JUNCTION BOX
. CEILING MOUNTED
JUNCTION BOX
� BOX, B�ANK COVER PLA
� BOX, OPEN
Q CABLE BOX, OPEN
p POWER POLE FOR
8 ELECTRICAL AND DATA.
PROVIDE JUNCTION BOX
ABOVE CEILING.
FLOOR BOX WITN POWER
�I� AND DATA, F�USH
MOUNTED
� POWER OUT�ET, DUPLEX
� POWER OUTLET,
QUADRUP�EX
QJ JUNCTION BOX
. CEILING MOUNTED
JUNCTION BOX
� BOX, BLANK COVER P�ATE
�p BOX, OPEN
' �• � � � �•
■
FLOOR BOX WITH POWER
�IQ AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH F�CJOR BOX WITH
0 Kj JUNCTION BOX AND � tQ JUNCTION BOX AND
DATA, FLUSH MOUNTED DATA, F�USH MOUNTED
DATA/COMMUNICATION DATA/COMMUNICATION
I�i OUTLET (PROVIDE BOX b OUT�ET
AND PUL� STRING ONLY)
DED DEDICATED CIRCUIT
GFCI GROUND FAU�T CIRCUIT
INTERRUPT OUT�ET
+42" HEIGHT OF ELECTRICAL
OR DATA DEVICE
GENERAL NOTES: ALL OUTLETS ARE TO INSTALLED 18" MIN.
A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES
UNLESS NOTED OTHERWISE.
REFER TO DOOR SCHEDULE AND COORDINATE WITN
TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES AND CARD READERS.
ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY
WSTAL�ED BY THE TENANT'S SECURITY CONTRACTOR AND ARE
TYPICALLY NOT SPECIFIED BY SCHOTT DESIGN, INC.
E01 PROVIDE JUNCTION BOX FOR ELECTRONIC STRIKE AT DOOR FOR
CARD READER (CARD READER BY TENANT) AND/OR MAG LOCK.
COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR
SCHEDULE FOR MORE DETAILS.
E02 COORDINATE COPIER RECEPTAC�E WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
E03 PROVIDE, POWER AND DATA RECEPTACLE FOR WALL MOUNTED
TELEVISION. EXACT HEIGHT AND LOCATION TO BE DETERMINED.
E04 PROVIDE JUNCTION BOX AT THIS LOCATION FOR TENANT'S
DISHWASNER AND/OR GARBAGE DISPOSAL.
E05 NOT USED.
PROVIDE FLUSH MOUNT FLOOR CORE FOR E�ECTRICA� AND
E06 DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON
EXACT LOCATION. �ESSEE CONTRACTOR TO PROVIDE PROPOSED
DEMOLITION PLAN FOR CONCRETE DEMO AND TRENCHING
REQUIRED FOR FLOOR BOXES.
E07 COORDINATE ALL STORAGE ROOM ELECTRICAL REQUIREMENTS
WITH TENANT.
� AREA NOT IN CONTRACT
❑ AREA OF WORK
ELECTRICAL PLAN
0 4' 8' 16'
N
� �
O
N � � �
� � �
c-�—n Z � '�
� ,vi � �
Q` Q t� O
W � � U
O � N
�� �-3
� 3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTE�IECTl1AL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
�
•
SSUE
02.02.15 REVIEW SET
02.06.15 STATE SUBMITTAL
03.12.15 A121 UPDATE
03.16.15 A111/A211/E111 NOTES
visoNs
�
PROJECT NUMBER
2014.423
N
PROJ. MGR DRAWN BY
MJ SS