HomeMy WebLinkAboutPacket for PC 07-21-15at
UPDATES
TAB
ŋ
7260 SHADELAND STATION
INDIANAPOLIS, IN 46256-3957
TEL 317.547.5580 FAX 317.543.0270
www.structurepoint.com
7260 SHADELAND STATION
INDIANAPOLIS, IN 46256-3957
TEL 317.547.5580 FAX 317.543.0270
www.structurepoint.com
(FUTURE BY OTHERS)
STREET ASTREET A
(FUTURE BY OTHERS)
ALLEY
PLAN
GROUND FLOOR
PLAN
TYPICAL FLOOR
PLAN
THIRD FLOOR
PLAN
FOURTH FLOOR
PLAN
ROOF FLOOR
BUILDING SECTION
PLAN
GROUND FLOOR
PLAN
ROOF FLOOR
(FUTURE BY OTHERS)
ALLEY
STREET A
F(
U
T
U
R
E
B
Y
O
T
H
E
R
S
)
7260 Shadeland Station | Indianapolis, Indiana 46256
2014.02691
GRAND BOULEVARD,
DATE
TEL 317.547.5580 | FAX 317.543.0270
CARMEL, IN. 46032 REVISION SCHEDULE
ISSUANCE INDEX
www.structurepoint.com
CERTIFIED BY
AND SUITES BY
GRAND & MAIN
MAIN STREET &
FAIRFIELD INN
DESCRIPTION
N
PROJECT PHASE:
MARRIOTT @
O
I
T
C
G
Project Number
U
N
I
R
D
T
N
S
E
N
02/16/2015
P
O
L
C
A
DESIGN
R
V
DATE:
O
O
F
R
NO.
T
P
PO
A
N
CONTACT RUSS MILLER:
FOR PRICING REQUESTS
rmiller@cbmcinc.com
317-780-8350
MOUNTING HEIGHT
LIGHT LOSS FACTOR
CALCULATED AT
FOOTCANDLES
rev. 08.19.2014
ALPHA (LED)
Alpha Floodlight
design . performance . technology
Max Weight: 27.0 lbs
www.beaconproducts.com
Max EPA: 1.32 sq ft
Sample AL-U60NB-1365K4X4UNVPECPMPCLBBT
Ordering////////
ABCDEFGHI
DETAILS A. MODELF. ELECTRICAL OPTIONS
AL-D Alpha, down light PEC photocell, button
16 3/8
1,3
AL-U Alpha, up light PCR-TL photocell, twist-lock
1,3
PCR-SC photocell, shorting cap
1,2
B. ENGINE-WATTS 2PF dual power feed
24NB-55 55 Watts - LED array
36NB-80 80 Watts - LED array G. MOUNTING OPTIONS
60NB-136 136 Watts - LED array WM wall mount
72NB-170 170 Watts - LED array PM 3 pier mount
72NB-220 220 Watts - LED array SF3 2 3/8 OD tenon (std.)
20
H. SHIELD OPTIONS
C. CCT - COLOR TEMP FL full louver
3K 3000K FV full visor
13
9 3/8
4K 4000K HL half louver
5K 5000K (std.)HV half visor
D. BEAM
2X2 I. COLOR
narrow spot
7 5/16
4X4BBT basic black textured
5X5BMT black matte textured
6X6WHT white textured
5X3MBT metallic bronze textured
Standard SF3 mount
Wall Mount (WM)
3X5BZT bronze textured
Slips 2 3/8 to 3 O.D. Tenon
DBT dark bronze textured
SHIELD OPTIONS
GYS gray smooth
E. VOLTAGE DPS dark platinum smooth
Full LouverFull Visor
UNV 120-277V GNT green textured
347 347V MST metallic silver textured
480 480V MTT metallic titanium textured
OWI old world iron
RAL
______________
MOUNTING OPTIONS
11 3/4
1/2
Half LouverHalf Visor
1
6
1
not available @ 347V or 480V input
2
available on 24NB-55, 72NB-170, and 72NB-220 only
3
PCR-TL and PCR-SC not available on AL-U
ORDERING
rev. 08.19.2014
ALPHA (LED)
Alpha Floodlight
design . performance . technology
Max Weight: 27.0 lbs
Max EPA: 1.32 sq ft
Intended Use: The Alpha Luminaire is a high performance LED energy and main-
tenance lighting solution, designed with optical versatility. Markets include large areas Warranty: Beacon luminaires feature a 5 year limited warranty. Beacon LED luminaires
requiring perimeter lighting, security fence lighting, truck terminals, car lots, recreational with LED arrays feature a 5 year limited warranty covering the LED arrays. LED drivers
are
covered by a 5 year limited warranty. PIR sensors carry a 5 year limited warranty from the
is intended to be used to reduce energy and maintenance associated with HID legacy sensor manufacturer. See Warranty Information on www.beaconproducts.com complete
lighting technology.
details and exclusions.
Construction:
aluminum that is pre-treated and powder-coated to meet the most rugged industry stan-
adhesion per ASTM D522, resists surface impacts of up to 160 inch-pound. All external
hardware is corrosion resistant.
Adjustable cast knuckle:
O.D. tenon. The knuckle is designed for continuous aiming adjustment without the use
is cast serrations. The cast knuckle uses cast external degree markers for aiming. The
aiming adjustment is design to operate with a single bolt adjustment. The Alpha can
adjust 30-degrees up from Nadir to straight up vertical.
Electrical Assembly:
components and shall be provided with an internal terminal block for AC power connec-
tions. The compartment is designed for an optional twist lock photo control.
Optical: The Alpha luminaire provides the best combination of vertical and horizontal
illumination while reducing light behind the poles. The Alpha features revolutionary indi-
vidual LED optical control based on TIR high performance acrylic optical designs. Flood
Lighting optics are available in 2x2, 4x4, 5x5, 6x6, 5x3 and 3x5 NEMA distributions and
are interchangeable with Type 2, 3,4, and Type V roadway and area lighting optics. The
Alpha also features a protective lens cover. Well designed optics result in fewer poles and
life-cycle cost as well as initial installation costs.
Lifeshield Circuit: Thermal circuit shall protect the luminaire from excessive tempera-
ture by interfacing with its 0-10V dimmable drivers to reduce drive current as necessary.
The factory-preset temperature limits shall be designed to ensure maximum hours of
-
and may be reliably operated in any ambient temperature up to 55ºC
(131 ºF).
Operation shall be smooth and undetectable to the eye. Thermal circuit shall directly
measure the temperature at the LED solder point. For maximum simplicity and reliability,
the device shall have no dedicated enclosure, circuit board, wiring harness, gaskets, or
hardware. Device shall have no moving parts, and shall operate entirely at low voltage
(NEC Class 2). Thermal circuit shall be designed to fail on, allowing the luminaire to
revert to full power in the event of an interruption of its power supply, or faulty wiring
Power/Lumens & Distributions
connection to the drivers.
Delivered
TM21
Calculated % Lumen
Delivered
EngineWattageLumens
Maint.
Device shall be able to co-exist with other 0-10V control devices (occupancy sensors,
LPW
(varies by optic)at 100,000 hrs
external dimmers, etc.). The device will effectively control the solder point temperature
as needed; otherwise it will allow the other control device(s) to function unimpeded.
24NB555000-566091-10396.19%
36NB808190-927091-10394.41%
Fasteners: All fasteners shall be stainless steel. When tamper resistant fasteners are
required, spanner HD (snake eye) style shall be provided (special tool required, consult
60NB13612600-1400093-10392.73%
factory).
72NB17016150-1700099-10485.79%
Drivers: Luminaires are equipped with an LED driver that accepts 100V through 277V,
72NB22019400-2040091-9583.97%
50 Hz to 60 Hz (UNV), or a driver that accepts 347V or 480V input. Power factor is .92 at
TM21 is the framework for taking LM-80 data and making useful LED lifetime projec-
full load. All electrical components are rated at 50,000 hours at full load and 40-C ambi-
tions. Reported and Calculated Lifetimes shown are based on hours at the time of
ent conditions per MIL-217F Notice 2. Optional 0 to 10 volt dimming drivers are available
this printing. For current Reported and Calculated hours please contact factory or
upon request. Component-to -component wiring within the luminaire will carry no more
Beacons web-site.
than 80% of rated current and is listed by UL for use at 600VAC at 50°C or higher. Plug
disconnects are listed by UL for use at 600 VAC.
CCT (COLOR TEMP) CRI
Lumen Output (Color Rendering)
Surge Protector: The on-board surge protector shall be a UL recognized component
Multipliers
for the United States and Canada and have a surge current rating of 10,000 Amps using
the industry standard 8/20 pSec wave. The LSP shall have a clamping voltage of 320V
5000° K = 1.0min 67 CRI
enclosure.
4000° K = .92min 70 CRI
3000° K = .75min 80 CRI
The luminaire shall bear a CSA label and be marked suitable
for wet locations.
SPECIFICATION
SB2
7260 Shadeland Station | Indianapolis, Indiana 46256
2014.02691
GRAND BOULEVARD,
DATE
TEL 317.547.5580 | FAX 317.543.0270
PLANTING
CARMEL, IN. 46032
REVISION SCHEDULE
DETAILS
ISSUANCE INDEX
www.structurepoint.com
CERTIFIED BY
AND SUITES BY
GRAND & MAIN
MAIN STREET &
FAIRFIELD INN
L101
DESCRIPTION
PROJECT PHASE:
MARRIOTT @
Project Number
02/16/2015
DESIGN
DATE:
NO.
Note: All groundcover beds shall be planted
12" Prepared Soil; Refer to Specifications
using triangular planting scheme. Refer to
using triangular planting scheme. Refer to
12" Prepared Soil; Refer to Specifications
Planting Schedule for On-Center planting
Planting Schedule for On-Center planting
Note: All perennial beds shall be planted
3" Shredded Hardwood Bark Mulch
3" Shredded Hardwood Bark Mulch
Area to Receive Hardwood Bark Mulch
Refer to Plans for Finish Grade.
Compacted Subgrade
Compacted Subgrade
Remove Container
Topsoil (As Specified)
Existing Grade
Split Peat Pot
dimension.
dimension.
Existing Grade
GROUNDCOVER PLANTING
PERENNIAL PLANTING
ACCORDING TO THE DETAILS ON THIS SHEET.
NOTE: LANDSCAPING MUST BE PLANTED
SPADE EDGE
3"
Not to ScaleNot to ScaleNot to Scale
3"
5"
1'-8½"1½"1'-2"
3'-0" (914)
ALLEY
TAB 10