Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.3 REFLECTED CEILING_ELEC_DATA PLANS.pdf
Project Number: Sheet Title: Issue Date: Sheet Number: Project: C A R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 4 6 0 3 2 B L U M O O N C A F E Drawn By Checked ByPrint Date Revisions: 6/17/15 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 2 0 0 S O U T H R A N G E L I N E R O A D I N D I A N A D E S I G N C E N T E R S U I T E 1 0 9 A1.3 REFLECTED CEILING/ELEC/ DATA PLANS Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 6/17/15 CONSTRUCTION DOCUMENTS 06/17/15 AJE MC THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 11 GE A M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. N N J 6 '-3 1 /2 " 8 '-0 " 8 '-0 " 5'-6"8'-0" 9'-0" 9'-0" 9'-0" OPEN 14'-0" OPEN OPEN OPEN 9'-6" 9'-6" OPEN 14'-0" CP7 CP10 CP3 CP1 CP2 CP4 CP5 CP6 CP6 CP7 CP8 CP9 3 3 75CS5EXS75CS5EXS NL B B B UUUU DN UP R R N N N N R R R R R F 220 220 2 2 0 220 220EP3 EP3 220 5 '-4 " EP5 EP2 EP2 EP8 EP8 EP1 EP1 EP1 EP2 +48" D KITCHEN 103 DINING 101 SERVICE 102 +42" +42" +42" GFI J J J +48" +48" 75CS5EXS75CS5EXS +48" +48" N N N N NN NNNN +42" AFF 5'-0" AFF 9'-0" AFF N N N DN UP SUITE 109 2,634 SF N N N N N N N N N N N N N DISHES 104 DINING 105 GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 5. 6. 7. 4. 3. 2. 1. DUPLEX WALL OUTLET. 220V CIRCUIT OUTLET.220 ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. FLOOR MOUNTED FLUSH MOUNT JUNCTION BOX FOR HARDWIRE CONNECTION.J G.C. TO INSTALL AND HOOK-UP ALL EQUIPMENT AND FURNITURE PROVIDED BY THE TENANT. TENANT'S DELIVERY OF THE EQUIPMENT AND FURNITURE TO THE SITE IS TO BE COORDINATED. VERIFY ALL ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION. ELECTRICAL/DATA PLAN NOTES: PROVIDE NEW POWER AND DATA OUTLETS SHOWN WITH AN 'N'. TIE NEW ELECTRICAL INTO EXISTING SUITE 109 ELECTRICAL PANEL. EP1 PROVIDE SEPARATE LINE ITEM COST FOR NEW ELECTRICAL/DATA IN SUITE 113. TIE NEW ELECTRICAL INTO EXISTING ELECTRICAL PANEL. EP2 CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: CEILING PLAN NOTES: LOCATE NEW SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. CP1 CP2 PROVIDE NEW SUSPENDED CEILING SYSTEM TO MATCH EXISTING. CEILING SYSTEM TO BE ARMSTRONG, 2'X4' GEORGIAN 793 SQUARE LAY-IN W/ PRELUDE XL 15/16" EXPOSED TEE GRID AT 14'-0" AFF. REUSE EXISTING CEILIG TILE REMOVED DURING DEMOLITION AND REPLACE ANY STAINED OR DAMAGED TILES. RELOCATE 2'X4' LIGHTS SHOWN WITH 'R' REMOVED FROM KITCHEN. NEW LIGHT 'N' TO MATCH EXISTING. WIRE LIGHTS TO BE CONTROLLED ON NEW SWITCH. 5. 6. 7. 4. 1. 2. 3. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. PROVIDE 4" ARMSTRONG AXIOM EDGE AND NEW CEILING TILES TO FINISH EXISTING CEILING CLOUD. RADIUS TO MATCH OPPOSITE SIDE. RELOCATE PENDANT LIGHTS SHOWN WITH 'R' REMOVED DURING DEMOLITION. PROVIDE NEW PENDANT LIGHT 'N' TO MATCH EXISTING. EXISTING OPEN CEILING TO REMAIN. OPEN CEILING TO BE PAINTED P2 TO MATCH EXISTING. CP3 CP4 CP5 RECONFIGURE THE EXISTING HVAC FAN-COIL UNIT AND DUCTWORK TO INCLUDE THIS SPACE.CP6 CP7 HVAC DUCT TO BE DESIGNED WITH BAFFLES TO REDUCE NOISE FROM HEAT PUMP UNIT.8. TIE NEW DINING AREA LIGHTING INTO EXISTING CIRCUIT WITH OTHER DINING AREA LIGHTS. PROVIDE SPIRAL DUCT, HARD PIPE CONDUIT FOR ALL WIRING, AND ALIGNMENT OF ALL VISIBLE ITEMS. CP8 INCLUDE ANY RECONFIGURATION OF HVAC SYSTEM NEEDED IN THE ADJACENT SUITE 113 AS SEPARATE LINE ITEM COST. CP9 PROVIDE NEW CEILING FAN. VERIFY IF FAN CAN BE TIED INTO EXISTING FAN CONTROL OR IF SEPARATE CONTROL IS NEEDED. NL D 3 NIGHTLIGHT LOCATION. THREE-WAY SWITCH. DIMMER SWITCH. TWO WAY SWITCH. GYPSUM BOARD CEILING. NEW 2 X 4 LAY-IN GRID SUSPENSION SYSTEM TO BE: ARMSTRONG, GEORGIAN 793 SQUARE LAY-IN W/ 15/16" PRELUDE GRID. DUAL-LITE TO REMAIN. REFLECTED CEILING LEGEND: EXISTING CEILING MOUNTED EXIT LIGHT W/ DIRECTION INDICATION 2' X 4' FLUORESCENT FIXTURE TO BE: MERCURY LIGHTING, LENS TROFFER, 35E-432-OCT-9A-ELB-UNI, W/ (4) 32W T8 LAMPS. HIGH BAY FIXTURE TO BE: IMPACT ARCHITECTURAL LIGHTING, P3412-PFR-242-BA-FROST/FLAT FROST-UNIVOLT, W/ (2) 42W CFTR TRIPLE TUBE LAMPS. MOUNT @ 12'-0" TO BOTTOM OF FIXTURE. NOTE: CONTACT KIM WINSHIP, CM BUCK & ASSOCIATES, 317.299.1515 X110, FOR ALL LIGHT FIXTURES, UNLESS NOTED OTHERWISE. RETURN AIR GRILL. N DENOTES NEW LIGHT FIXTURE. R DENOTES RELOCATED LIGHT FIXTURE. 2 X 2 LAY-IN GRID SUSPENSION SYSTEM TO MATCH EXISTING. ARMSTRONG, TINCRAFT CIRCLES 8008, COLOR WHITE, FLUSH TEGULAR W/ 15/16" PRELUDE GRID. CEILING FAN TO BE: EMERSON HF956BS, 56" BRUSHED STEEL W/ CFDRX-BS DOWNROD. MOUNT AT 12'-0" TO BOTTOM OF FAN. SCALE: 1/8" = 1'-0" 1 Reflected Ceiling Plan A1.3 SCALE: 1/8" = 1'-0" 2 Electrical plan A1.3 11 L 10 9 MK L 11 10 9 MK