Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T1.4 1ST FLOOR LIFE SAFETY PLAN.pdf
Project Number: Sheet Title: Issue Date: Sheet Number: Project: C A R M E L , I N D I A N A By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) 4 6 0 3 2 B L U M O O N C A F E Drawn By Checked ByPrint Date Revisions: 6/17/15 State Release Set COPYRIGHT & OWNERSHIP OF DOCUMENTS 2 0 0 S O U T H R A N G E L I N E R O A D I N D I A N A D E S I G N C E N T E R S U I T E 1 0 9 T1.4 1ST FLOOR LIFE SAFETY PLAN Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 6/17/15 CONSTRUCTION DOCUMENTS 06/17/15 AJE MC THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 11 GE A M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. BUILDING CODES: SPRINKLER SYSTEM: PROJECT BUILDING CODES BUILDING HEIGHT: OCCUPANCY LOAD:175 PERSONS PER TABLE 1004.1.2. FULLY PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM AS PER NFPA 13 - 2010 CODE COMPLIANCE SCHEDULE Indiana Building Code, 2014 Edition (IBC 2012) Indiana Accessibility Code (ICC/ANSI A117.1-2009) Minimum Design Loads (ASCE 7-2010) Indiana Plumbing Code, 2012 Edition (UPC 1997) Indiana Mechanical Code, 2014 Edition (IMC 2012) Indiana Fuel Gas Code, 2014 Edition (IFGC 2012) NFPA 13-2010 Installation of Sprinkler Systems OCCUPANCY Group A-2 - Assembly Use Group CONSTRUCTION TYPE: Type II-B - Non-combustible construction materials; Non-rated 2014 2014 2014 2012 2014 2014 2012 PROJECT AREA: Indiana Electrical Code, 2008 Edition (NFPA 70-2008)2009 APPROVALS:PROJECT NO. 323831 CDR LETTER FOUNDATION RELEASE 02.02.07 PROJECT NO. 323831 CDR LETTER STANDARD RELEASE - ARCHITECTURAL 02.16.07 PROJECT NO. 323831 CDR LETTER STANDARD RELEASE - MEP 02.04.08 FIREWALL VARIANCE NO. 10-04-57 (A,B,C,D) 04.06.10 2 STORY. 2,634 S.F. GROSS TENANT AREA General Administrative Rules (675 IAC 12)2006 NFPA 72-2010 National Fire Alarm Code 2014 N L L.7L.6 L.9 MJK.1K K.5G.3 G.4 H H.5 .6 .5 1 F 5 7 G 6 3 2.9 2 8 8.1 A.1 C E 10 4 H.9 11 9.1 9.9 10.9 10.85 7.8 7.3 3.8 3.3 BA.5A A.2 D 9 SCOPE OF WORK 1 0 3 127B 127C 127A 1 0 2 C 123D 127D 1 0 9 D 111D 109E 101C 123B 123C 123A A R E A -A A R E A -B AREA-B AREA-C A R E A -A A R E A -B AREA-B AREA-C 52'-7" FEET OF TRAVEL BLUE MOON EXPANSION SUITE 109 7 0 '-7 " F E E T O F T R A V E L EXIT EXIT MEN'S RESTROOM WOMEN'S RESTROOM 75CS5EXS 75CS5EXS UP DN UP DN DN UP UP DN UP DN SCALE: 1/16" = 1'-0" 1 LIFE SAFETY PLAN T1.4 BLU MOON EXPANSION 555 SF (ABOVE PARKING GARAGE)