Loading...
HomeMy WebLinkAbout15070024 Building PlansProject Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: B E A U T Y + G R A C E C a r m e l , I n d i a n a 4 6 0 3 2 C a r m e l C i t y C e n t e r - B l d g A 7 5 1 H a n o v e r P l a c e , S u i t e 1 5 9 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 6.05.2015 N PEDCOR DESIGN GROUP T1.1 Title Sheet CONSTRUCTION DOCUMENTS AJE MC6/04/2015 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 751 Hanover Place ARCHITECT: JAMES ROBERT STUTZMAN, AIA, NCARB PEDCOR DESIGN GROUP, LLC 355 CITY CENTER DRIVE CARMEL, INDIANA 46032 PHONE: (317) 705-7979 FAX: (317) 705-7980 DRAWING INDEX T1.1 Title Sheet SP.1 Specifications LS.1 Life Safety Plan LS.2 Life Safety Plan A1.1 Demolition Plans A1.2 Construction/Finish Plans A1.3 Ceiling/Elec/Data Plans A4.1 Schedules/Enlarged Restroom Plans 1 A1.1 SECTION CUT WINDOW NUMBER DOOR NUMBER ROOM NAME & NUMBER ELEVATION REFERENCE 1 A1.1 SECTION REFERENCE DETAIL REFERENCE REFERENCE SYMBOLS 1 A1.1 WHICH DETAIL APPEARS INDICATES SHEET IN INDICATES DETAIL NUMBER A 1 A1.1 EL. = 100'-0" T.O. FINISHED FLOOR ELEVATION MARK 1 A1.1 100 OFFICE 100 SCALE: 1/8" = 1'-0" PLAN BUILDING OWNER: CARMEL CITY CENTER, L.L.C. 770 THIRD AVENUE SW CARMEL, INDIANA 46032 PHONE: (317) 587-0320 FAX: (317) 587-0350 CI T Y C E N T E R BE A U T Y + G R A C E SITE MAP SITE VICINITY MAP SITE MAP C H E C K SE T Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: B E A U T Y + G R A C E C a r m e l , I n d i a n a 4 6 0 3 2 C a r m e l C i t y C e n t e r - B l d g A 7 5 1 H a n o v e r P l a c e , S u i t e 1 5 9 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 6.05.2015 N PEDCOR DESIGN GROUP A1.2 Construction/Finish Plans CONSTRUCTION DOCUMENTS AJE MC6/04/2015 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 751 Hanover Place N N FN1 FN2 FN3 FN4 FN5 1.ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. CONTRACTOR TO VERIFY LEAD TIME AS SOON AS CONTRACT IS AWARDED AND NOTIFY ARCHITECT IF SPECIFIED FINISHES WILL NOT BE AVAILABLE. DESIGN FEES MAY ACCRUE FOR TIME SPENT TO RESELECT ANY MATERIALS WHICH BECOME UNAVAILABLE DUE TO DELAYS IN ORDERING. BASE IN REST ROOMS MUST BE MINIMUM 5" HEIGHT TO MEET BOARD OF HEALTH CODE. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED OR ARE TO BE EASED USING LATEX TO ACHIEVE A SMOOTH TRANSITION FROM FINISH TO FINISH. ALL NEW DOORS TO BE STAINED ST1 UNLESS NOTED OTHERWISE. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED SEMI-GLOSS TO MATCH ADJACENT WALL. 1. 2. 3. 4. 5. 9. 10. 6. 7. GROUT TO HAVE H.B. FULLER CONSTRUCTION PRODUCTS, GROUT BOOST ADDITIVE STAIN BLOCKER. 8. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK TO DESIGNER FOR REVIEW AND APPROVAL BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. PAINT ALL EXPOSED METAL SURFACES (i.e.. GRILLS, HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFACE. ALL DRYWALL BULKHEADS ARE TO BE PAINTED P2, UNLESS NOTED OTHERWISE ON REFLECTED CEILING PLANS. PAINT NEW PLYWOOD PHONE BOARD WITH FIRE RETARDANT PAINT. COLOR TO MATCH ADJACENT WALL FINISH. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. ALTERNATES GENERAL FINISH NOTES FINISH PLAN NOTES STAINED CONCRETE MFG: SCOFIELD PRODUCT: LITHOCHROME, TINTURA STAIN COLOR: TBD LOCATION: GENERAL CONTACT: SCOTT REYES, 586.292.1492 VINYL BASE MFG: JOHNSONITE COLOR: XXX SIZE: 4" COVE LOCATION: GENERAL CONTACT: BARB LUSTIG, 317.443.8137 BASE FLOORCOVERING PAINT MFG: SHERWIN WILLIAMS COLOR: ANEW GRAY SW7030 FINISH: EGGSHELL LOCATION: GENERAL P1 PAINT FINISH LEGEND WOOD FINISHES CUT EXISTING WALL TILE TO ALLOW FOR 6" TILE BASE. USE SCHLUTER TRIM AT CUT EDGE TO BE: SATIN NICKEL. PORCELAIN TILE - 12"x12" MFG: ORCHID PORCELAIN PATTERN: ERIS COLOR: BISCOTTI 203 MORTAR: TEC, 1FLEX GROUT: TEC, 991 PARCHMENT LOCATION: RESTROOM PAINT MFG: SHERWIN WILLIAMS COLOR: AGREEABLE GRAY SW7029 FINISH: FLAT LOCATION: BULKHEADS P2 PAINT-DRY FOG MFG: SHERWIN WILLIAMS COLOR: SW6991 BLACK MAGIC FINISH: FLAT LOCATION: OPEN CEILING P3 P4 PAINT MFG: SHERWIN WILLIAMS COLOR: XXX FINISH: SATIN LOCATION: ACCENT P5 PAINT MFG: SHERWIN WILLIAMS COLOR: SHOJI WHITE SW7042 FINISH: EGGSHELL LOCATION: RESTROOM SPECIES: WALNUT CUT: PLAIN-SLICED MFG: MARSHFIELD LOCATION: DOORS COLOR: CLEAR WOOD STAINST1 ZINC TRANSITION STRIP BETWEEN CONCRETE AND TILE TO BE SCHLUTER, SATIN ANODIZED ALUMINUM. PORCELAIN TILE - 12"x12" MFG: ORCHID PORCELAIN PATTERN: ERIS COLOR: BISCOTTI 203 MORTAR: TEC, 1FLEX GROUT: TEC, 991 PARCHMENT LOCATION: RESTROOM WALLCOVERING W1 END WALL TILE AT INSIDE CORNER. PROVIDE STAINED CONCRETE MOCK UP ON EXISTING CONCRETE IN THIS AREA. ALL OPEN, EXPOSED CEILINGS TO MATCH P3. EXISTING, OPEN PAINTED CEILING TO BE TOUCHED UP AS NEEDED AND DUCTWORK DUSTED AND CLEANED. B1 SC1 PCT1 3'-0"5'-5 1/8"5'-5 1/8" 7'-4 1/4"6'-0"2'-11 3/4" 5 '-2 " 5 '-2 " 4'-7 3/4" FP7 FP2 FP10FP10 FP1 FP3 FP7FP7 FP7 FP7 FP14 FP14 FP11 FP8 FP12 FP1 FP9 FP15 FP13 FP1 1 0 5 101 104 RESTROOM 105 STORAGE/ OFFICE 104 RETAIL 100 DRESSING 102 HALL 109 W 3 W3 D I S P L A Y 1 0 1 "Q U O T E " W A L L SUITE 159 1674 S.F. DRESSING 103W4 W4 W2 W 1 W 1 Stair SA6 Stair SA6 P Q Q.2P.1 P.5 17.1 17 16.1 16 16.9 FN4 FN3 FN2 FN1 FN1 FN5 FN5 RESTROOM 105 STORAGE/ OFFICE 104 RETAIL 100 DRESSING 102 HALL 109 P4 P1 P1 P1 P1 D I S P L A Y 1 0 1 "Q U O T E " W A L L SUITE 159 1674 S.F. DRESSING 103 P5 P5 Stair SA6 Stair SA6 W1 PCT1 SC1 B1 SC1 B1 SC1 B1 SC1 B1 P Q Q.2P.1 P.5 17.1 17 16.1 16 16.9 13. APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. 14. 15. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 16. ALL CORE WALLS AND DEMISING WALLS SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES.PROVIDE 3/4"x4'x8' FIRE RETARDANT PLYWOOD PHONE BOARD IN MECHANICAL ROOM. PHONE BOARD TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. CONFIRM QUANTITY OF EXTINGUISHERS WITH FIRE DEPARTMENT. IF EXTINGUISHERS NEED TO BE ADDED VERIFY LOCATIONS WITH THE ARCHITECT. INFILL WHERE DOOR WAS REMOVED. MATCH ADJACENT WALL CONSTRUCTION. ALIGN FINISHED FACES. FP12 FP11 FP10 FP9 FP8 CONSTRUCTION PLAN NOTES: FP1 FP2 FP3 FP4 FP5 FP6 FP7 4 0 0 NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. DENOTES NEW MILLWORK. DENOTES AREA NOT IN CONTRACT. GENERAL CONSTRUCTION NOTES: DIMENSIONS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. 1. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES.2. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION.3. 4. 5. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. 6. 7. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). 8. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL. 9. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. 10. ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH AND INSTALLED ACCORDING TO CODE. LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW OF AESTHETIC PURPOSES ONLY. 11. 12. AT ENDS OF WALL AND AT 48" O.C. WALLS TO EXTEND TO 11'-6" AFF. PROVIDE METAL KNEE BRACES NEW PARTIAL HEIGHT WALL CONSTRUCTION TO BE 3-5/8" 20 GAUGE METAL STUDS @16"O.C. 4 -7 /8 " 4 -7 /8 " 4 -7 /8 " 7 -1 /8 " WITH 5/8" GYPSUM WALL BOARD EACH SIDE. 3-5/8" 25 GAUGE METAL STUDS @16"O.C. WALLS TO EXTEND TO DECK ABOVE. W4 WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W3 3-5/8" 20 GAUGE METAL STUDS @16" O.C. PROVIDE 6" INSULATION INSIDE WALL WALLS TO EXTEND TO DECK ABOVE. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W2 WALLS TO EXTEND TO DECK ABOVE. 6" 20 GAUGE METAL STUDS @16"O.C. WITH 5/8" GYPSUM WALL BOARD EACH SIDE. W1 EXISTING PARTITION TO REMAIN NEW WALL PARTITION NEW LOW WALL PARTITION WALL LEGEND: NOTES: USE MOISTURE-MOLD RESISTANT GYPSUM WALLBOARD MEETING ASTM D3273 ON ALL WALL SURFACES RECIEVING FRP PANELS AND IN RESTROOMS. INSULATION FOR INTERIOR WALL APPLICATION SHALL BE FORMALDEHYDE-FREE, UNFACED, GLASS-FIBER BLANKET INSULATION IN BATT FORM CONFORMING TO ASTM C 655, TYPE I, WITH THICKNESS TO BE EQUAL OR GREATER THAN THE STUD THICKNESS OF THE WALL INTO WHICH IT IS INSTALLED. CEMENT BOARD TO BE USED IN ALL SECTIONS AND PORTIONS OF WALLS WITH TILE FINISH. SEE FINISH PLANS TO COORDINATE FINISH LOCATIONS. SEE A4.2 FOR DOOR SCHEDULE. ALL PENETRATIONS IN RATED WALL PARTITIONS AND FLOOR SYSTEMS SHALL BE FIRE RATED ASSEMBLIES. SUBMIT PRODUCT DATA AND ASSEMBLY DRAWINGS WITH TEST FILE NUMBERS FOR REVIEW. PROVIDE A WATER METER TO MONITOR WATER SUPPLY TO THE SHOWROOM. EXISTING DOOR AND FRAME. CLEAN EXISTING WINDOW SHADES AND CONFIRM THEY ARE IN WORKING ORDER. FP13 FP14 FP15 PROVIDE AND INSTALL NEW WATER HEATER ABOVE RESTROOM CEILING. PROVIDE 3-5/8" INSULATION INSIDE WALL RELOCATE PLUMBING LINES AND INSTALL SINGLE BOWL SINK AND COUNTER ASSEMBLY REMOVED DURING DEMOLITION. NOT USED. NOT USED. ALL WALLS TO BE PATCHED AND PAINTED UNLESS NOTED OTHERWISE. INSTALL GRAB BARS REMOVED DURING DEMO. PROVIDE BLOCKING AS NEEDED. INSTALL MIRROR REMOVED DURING DEMO ABOVE SINK. PROVIDE BLOCKING AS NEEDED FOR TENANT PROVIDED AND INSTALLED CURTAIN ROD AND DRAPERY. VERIFY MOUNTING HEIGHT IN THE FIELD. NOT USED. SCALE: 3/16" = 1'-0" 1 Construction Plan A1.2SCALE: 3/16" = 1'-0" 2 Finish Plan A1.2 Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: B E A U T Y + G R A C E C a r m e l , I n d i a n a 4 6 0 3 2 C a r m e l C i t y C e n t e r - B l d g A 7 5 1 H a n o v e r P l a c e , S u i t e 1 5 9 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 6.05.2015 N PEDCOR DESIGN GROUP A1.1 Demolition Plans CONSTRUCTION DOCUMENTS AJE MC6/04/2015 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 751 Hanover Place N N DP1 DP3 DP1 DP1 DP1 DP2 DP2 DP5 DP3 DP4 DP6 DP4 DP4 DP2 DP6 DP6 DP4 DP7 DP8 DP9 DP10 DP11 DP11 DP11 DP11 DP12 DP6 Stair SA6 Stair SA6 P Q Q.2P.1 P.5 17.1 17 16.1 16 16.9 DP15 DP13 DP13 DP13 DP14 DP14 DP14 DP17 DP14 DP14 DP14 DP14 DP16 DP17 DP14 DP18 DP18 DP14 DP17 DP15 DP15 DP15 Stair SA6 Stair SA6 P Q Q.2P.1 P.5 17.1 17 16.1 16 16.9 J REMOVE LIFE SAFETY ITEMS AS SHOWN. SAVE FOR REUSE. REMOVE LIGHT FIXTURES SHOWN ON THE PLAN. SAVE LIGHT FIXTURES FOR REUSE. REMOVE ELECTRICAL/DATA/TV OUTLETS AND BLANK JUNCTION BOXES, INCLUDING ALL ATTACHED WIRING BACK TO MAIN PANEL. REMOVE EXISTING FLOOR AND WALL TILE. PREP FOR STAINED CONCRETE. REMOVE EXISTING CARPET TILE AND BASE. PREP FOR STAINED CONCRETE. REMOVE EXISTING DOORS AND FRAMES. SAVE FOR REUSE. REMOVE EXISTING WALLS SHOWN AS DASHED AND PREP FOR NEW CONSTRUCTION. DP10 DP9 DP8 DP7 DEMOLITION PLAN NOTES: DP1 DP2 DP3 DP4 DP5 DP6 DP11 REMOVE EXISTING SUSPENDED CEILING AND GRID WHERE SHOWN AND SAVE FOR REUSE. REUSE DEMO'D GRID AS MUCH AS POSSIBLE. DP12 DP13 DP14 1. DEMOLITION LEGEND:GENERAL DEMOLITION NOTES: REMOVE ALL WALLS, MILLWORK, DOORS AND DOOR FRAMES AS SHOWN DASHED. RESERVE DOORS AND DOOR FRAMES FOR RE-USE IN NEW PROJECT SCOPE. 2. 3. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNER'S DIRECTION UNLESS NOTED OTHERWISE. EXISTING CONSTRUCTION TO BE REMOVED. EXISTING PARTITION TO REMAIN. DUPLEX WALL OUTLET TO BE REMOVED. PHONE/DATA WALL OUTLET TO BE REMOVED. T THERMOSTAT TO BE REMOVED. 5. 4. DEMOLISH DENOTED EXISTING CEILING SYSTEM CLEARLY AND CLEANLY BACK TO A POINT WHERE INSTALLATION OF NEW CEILING SYSTEM IS POSSIBLE. SEE CEILING DEMOLITION PLAN FOR EXTENT OF WORK. DEMOLISH EXISTING WALL AND/OR FLOOR SURFACES BACK TO A POINT WHERE INSTALLATION OF NEW FLOORING FINISHES IS POSSIBLE. 6. 7. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH PLAN TO COORDINATE LOCATION OF NEW FINISHES. REMOVE ELECTRICAL AND DEVICE LINES IN WALLS THAT ARE TO BE REMOVED, INCLUDING ALL ATTACHED WIRING. DEMOLISH ELECTRICAL DEVICES AND WIRING BACK TO A POINT WHEREAS PROPER PREPARATION FOR NEW FINISHES IS POSSIBLE. SEE ELECTRICAL AND FINISH PLANS FOR FURTHER INFORMATION. 8. ALL DEMOLISHED RECEPTACLES FROM EXISTING WALLS TO REMAIN SHALL HAVE DRYWALL PATCHED AND REPAIRED PRIOR TO INSTALLATION OF WALL FINISHES. 2X4 LIGHT FIXTURE TO BE REMOVED. EXIT SIGN TO BE REMOVED. LIGHT SWITCH TO BE REMOVED. EMERGENCY LIGHTING TO BE REMOVED. CEILING TILE AND GRID TO BE REMOVED. REMOVE ALL EXISTING FLOOR OUTLETS SHOWN. PROVIDE AN EVEN FLOOR SURFACE IN PREPARATION FOR NEW FLOOR FINISH. HORN/STROBE AND PULL STATION TO BE REMOVED. DENOTES AREA NOT IN CONTRACT. 2X2 LIGHT FIXTURE TO BE REMOVED. ELECTRICAL JUNCTION BOX AT THE CEILING TO BE REMOVED. BLANK WALL OUTLET TO BE REMOVED.B CABLE WALL OUTLET TO BE REMOVED. REMOVE EXISTING CASEWORK AND COUNTERS. REMOVE EXISTING PLUMBING FIXTURES, TOILET PARTITIONS, AND ACCESSORIES. SAVE FOR REUSE AS NOTED. STORE REMAINING ITEMS NOT REUSED ON THIS PROJECT. REMOVE EXISTING ART HANGING SYSTEM. SAVE FOR REUSE. REMOVE EXISTING WATER HEATER AND RELATED ITEMS. REMOVE EXISTING FIREPLACE AND SAVE FOR REUSE. REMOVE EXISTING WALL TILE ON ALL WALLS EXCEPT FOR PLUMBING WALL AT TOILET. REMOVE EXISTING COAT ROD/SHELF AND HANGERS. SAVE FOR REUSE. DP15 REMOVE DRYWALL CEILING CLOUDS AND ASSOCIATED HANGING SYSTEM. DP16 REMOVE DRYWALL COVE CEILING. DP17 REMOVE DRYWALL CEILING. DP18 SCALE: 3/16" = 1'-0" 1 Demo Plan A1.1SCALE: 3/16" = 1'-0" 2 Demo Ceiling Plan A1.1 Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: B E A U T Y + G R A C E C a r m e l , I n d i a n a 4 6 0 3 2 C a r m e l C i t y C e n t e r - B l d g A 7 5 1 H a n o v e r P l a c e , S u i t e 1 5 9 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 6.05.2015 N PEDCOR DESIGN GROUP A1.3 Ceiling/Elec/Data Plans CONSTRUCTION DOCUMENTS AJE MC6/04/2015 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 751 Hanover Place N N CEILING HEIGHT IS INDICATED BY BENCHMARK UNLESS NOTED OTHERWISE. SUBCONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO THE DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. GENERAL CEILING NOTES:CEILING PLAN NOTES: LOCATE NEW SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. CP1 CP2 EXISTING BULKHEADS TO REMAIN. 11. 10. 9. 8. 5. 6. 7. 4. 1. 2. 3. N NL D 3 NIGHTLIGHT LOCATION. THREE-WAY SWITCH. DIMMER SWITCH. TWO WAY SWITCH. GYPSUM BOARD CEILING. DENOTES NEW SWITCH LOCATION. INDICATION TO BE DUAL-LITE LES SERIES, LED EDGE LIT EXIT SIGN OR EQUAL. CEILING MOUNTED EXIT LIGHT W/ DIRECTION REFLECTED CEILING LEGEND: MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR AND ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. ELECTRICAL CONTRACTOR AND ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN-BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS AND ENGINEER CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. HVAC UNITS TO BE LOCATED ABOVE ACCESSIBLE FINISHED CEILING IN RESTROOM TO REDUCE NOISE FROM HEAT PUMP UNIT. EMERGENCY LIGHTING SHALL BE CONNECTED TO THE EMERGENCY GENERATOR. LIGHTS TO BE MOUNTED AT 11'-6" AFF, UNLESS NOTED OTHERWISE. LAMPS IN ALL FIXTURES TO BE 3500K COLOR TEMPERATURE. PROVIDE OPEN CEILING WITH ALL EXPOSED SURFACES TO BE PAINTED P3. PROVIDE SPIRAL DUCT, HARD PIPE CONDUIT FOR ALL WIRING, AND ALIGNMENT OF ALL VISIBLE ITEMS. CP3 CP4 INFILL BULKHEAD TO MATCH EXISTING CONSTRUCTION WHERE WALL WAS REMOVED. BULKHEAD TO BE PAINTED P2. PROVIDE NEW BULKHEAD WITH RELOCATED WALL WASH DOWNLIGHTS. RETURN BULKHEAD TO DECK ABOVE. PROVIDE LIGHTING CONTROL TIMER SYSTEM FOR THIS SUITE WITH (6) ZONES. PROVIDE (1) ZONE FOR THE DISPLAY WINDOW LIGHTS AT PERIMETER AND (1) FOR EXTERIOR SIGNAGE. CP5 CP6 CP7 CP8 CP9 CP10 EXISTING CEILING TILES TO REMAIN. REPLACE ANY STAINED OR DAMAGED TILES. PROVIDE ACOUSTICAL CEILING TO BE: ARMSTRONG, DUNE. SEE LEGEND FOR SPECIFICATIONS. LIGHT FIXTURES TO BE ON OCCUPANCY SENSOR. CP11 CP12 CP13 CP14 INSTALL LIFE SAFETY ITEMS REMOVED DURING DEMO. INCLUDE PLAN AS PART OF SUBMITTAL PROCESS FOR DESIGNER REVIEW. CP15 2 X 2 LAY-IN GRID SUSPENSION SYSTEM TO BE: ARMSTRONG, DUNE TEGULAR WITH 15/16" PRELUDE XL GRID. RESTROOM EXHAUST CONNECTION. PROVIDE GRILL IN CEILING FOR CONNECTION TO BUILDING EXHAUST SYSTEM. NOTE: CONTACT ANGELA JUNGBAUER, TECHLITE CORP., 317.578.2626 FOR ALL LIGHT FIXTURES. SEE LEGEND FOR "OR EQUAL". RELOCATED WALL WASH FIXTURE TO BE: NORA LIGHTING, NHPV6-2642-EL AND NTS-734-W W/ (1) 26W CFTR TRIPLE TUBE LAMP OR EQUAL. EXISTING PENDANT FIXTURE TO BE: JUNO LIGHTING, 12P-32TB-CL-DIM-P60B OR EQUAL. W/ (1) 32W CFTR TRIPLE TUBE LAMP. LIGHTS TO BE ON DIMMERS. MOUNT AT 11'-6" TO BOTTOM OF FIXTURE. EXISTING OR RELOCATED 6" RECESSED DOWNLIGHT TO BE: NORA LIGHTING, NHPV6-2642-EL W/ (1) 26W CFTR TRIPLE TUBE LAMP OR EQUAL. NEW TRACK LIGHTS TO BE: NORA LIGHTING, SINGLE-CIRCUIT TRACK NT-3000 WITH TRACK HEADS NTH-108. MOUNT AT 11'-6" AFF TO BOTTOM OF FIXTURE, VERIFY IN FIELD. DUAL-LITE LZ SERIES OR EQUAL. MOUNT AT 10' AFF. BATTERY BACK-UP EMERGENCY LIGHT FIXTURE TO BE RELOCATED WALL SCONCE TO BE: KICHLER LIGHTING, TULLY 3 LT, 45151OZ, OLDE BRONZE. SEE ELEVATION FOR MOUNTING HEIGHT. TO BE MERCURY LIGHTING, MER-CWLXTE, WET LOCATION LED COMBO UNIT OR EQUAL. OUTDOOR EXIT LIGHT/EMERGENCY COMBO RELOCATE SCONCE REMOVED FROM MEN'S RESTROOM AT THIS LOCATION. TIE INTO OCCUPANCY SENSOR. EXISTING LIGHT FIXTURES TO REMAIN. REPLACE ANY NON-WORKING LAMPS. ALL LAMPS TO BE SAME COLOR TEMPERATURE. NEW ACCENT LIGHT FIXTURES PROVIDED BY TENANT, INSTALLED BY G.C. PROVIDE NEW JUNCTION BOX OR ACCESS TO EXISTING AS NEEDED. LIGHTS TO BE TIED TOGETHER ON CIRCUIT. RELOCATE LIGHTS REMOVED DURING DEMO NOTED WITH AN 'R'. REVIEW HVAC DESIGN AND PROVIDE SEPARATE SYSTEM FOR THIS SUITE. CONTACT SIGNS BY DESIGN TO COORDINATE INSTALL OF ILLUMINATED SIGN AND SOUTH AWNING LOGO. SIGNAGE IS TENANT COST. CONTACT, TOBIE WARSTLER, 317-876-7900. PROVIDE NEW ACOUSTICAL CEILING SYSTEM TO BE: ARMSTRONG, 2'X2' DUNE W/ 15/16" PRELUDE GRID. REUSE EXISTING TILE AND GRID REMOVED DURING DEMO AS MUCH AS POSSIBLE. PROVIDE OCCUPANCY SENSOR FOR OFFICE AND RESTROOM. R R N EXTEND EXISTING BULKHEADS AT THESE LOCATIONS TO ALIGN WITH NEW WALLS.CP16 RELOCATE EXISTING LIGHT FIXTURES AS SHOWN.CP17 39'-5/8" 9 '-6 5 /8 " 1 5 '-2 " 2'-0" 2 '-4 1 /4 " 1 3 '-6 1 /4 " 2 '-3 1 /8 " 8 '-0 " 8 '-0 " 3'-0"8'-0"8'-0"8'-0" EQ.EQ.EQ.EQ. E Q . E Q . E Q . E Q . 2'-8 1/2"5'-10"2'-8 1/2" E Q . E Q . EQ.EQ. E Q . E Q . E Q . E Q . EQ.EQ. OPEN 9' 9' OPEN OPEN 11'-6" 11'-6" 11'-6"11'-6" 10' 8'8' 11'-6" 11'-6" CP7 CP7 CP1 CP1 CP6 CP17 CP3 CP3 CP3 CP6 CP2 CP5 CP3 CP4 CP4 CP4 CP4CP4 CP6 CP6 CP15 CP5 CP8 CP9 CP9 CP9 CP16CP16 CP10 CP11 CP9 CP9 CP12 CP13 CP13 CP14 R N R R R R R R R R R R R R N N N CL CL Stair SA6 Stair SA6 P Q Q.2P.1 P.5 17.1 17 16.1 16 16.9 J J EP1 EP3 EP1 EP1 EP3EP3 EP2 EP4 RESTROOM 105 STORAGE/ OFFICE 104 WP RETAIL 100 DRESSING 102 HALL 109 +44" +44" +102" D I S P L A Y 1 0 1 "Q U O T E " W A L L SUITE 159 1674 S.F. DRESSING 103 N N N N N N N +xx" D Stair SA6 Stair SA6 P Q Q.2P.1 P.5 17.1 17 16.1 16 16.9 J GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. ELECTRICAL/DATA PLAN NOTES: FURNITURE, FIXTURES, AND EQUIPMENT SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 5. 6. 7. 8. 4. 3. 2. 1.EP1 PROVIDE NEW ELECTRICAL AND DATA OUTLETS SHOWNS WITH AN 'N'. EP2 DUPLEX WALL OUTLET. DEDICATED CIRCUIT OUTLET.D CABLE TV OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44"HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR AND ENGINEER TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. MECHANICAL CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. ELECTRICAL CONTRACTOR AND ENGINEER IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. ENGINEER IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. DESIGN-BUILD CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS AND ENGINEER CERTIFICATION CALCULATIONS AND SPECIFICATIONS FOR REVIEW AND OBTAINING PERMITS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. 9. 220V CIRCUIT OUTLET.220 ELECTRICAL JUNCTION BOX. QUAD WALL OUTLET. LOCATION OF EXISTING ELECTRICAL PANEL IN SERVICE CORRIDOR. RELOCATE EXISTING ELECTRICAL WHERE CASEWORK WAS REMOVED TO 18" AFF TO CENTER OF BOX.EP3 EP4 WATERPROOF OUTLET.WP PROVIDE 20 AMP DEDICATED JUNCTION BOX FOR FUTURE EXTERIOR SIGNAGE. COORDINATE INSTALLATION AND WIRING OF SECURITY AND SPEAKERS/MUSIC SYSTEMS WITH TENANT. WALL MOUNTED ELECTRICAL JUNCTION BOX. SCALE: 3/16" = 1'-0" 1 Reflected Ceiling Plan A1.3SCALE: 3/16" = 1'-0" 2 Elec/Data Plan A1.3 Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: B E A U T Y + G R A C E C a r m e l , I n d i a n a 4 6 0 3 2 C a r m e l C i t y C e n t e r - B l d g A 7 5 1 H a n o v e r P l a c e , S u i t e 1 5 9 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 6.05.2015 N PEDCOR DESIGN GROUP A4.2 Schedules/ Enlarged RR Plans CONSTRUCTION DOCUMENTS AJE MC6/04/2015 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 751 Hanover Place HARDWARE L = L O C K S E T 7'-0" 7'-0"RESTROOM 104 105 3'-0" 3'-0"1 3/4" 1 3/4" WOOD WOOD HM HM 7'-0" SIZE DISPLAY R O O M N A M E O P E N I N G N U M B E R 101 W I D T H H E I G H T E L E V A T I O N M A T E R I A L 1 3/4" T H I C K DOOR M A T E R I A L E L E V A T I O N HM FRAME PP,CL,S, DB L,CL,S REMARKS D O O R S C H E D U L E STOR/OFFICE 3'-0"WOOD D1 D1 D1 D1 D1 D1 S = S T O P P S = P A S S A G E S E T C L = C L O S E R PP,CL 1. DOOR SCHEDULE NOTES: ALL DOORS TO BE STAINED ST1. 2. 3. ALL HOLLOW METAL DOOR FRAMES TO BE PREPPED AND PAINTED SEMI-GLOSS TO MATCH ADJACENT WALL. OWNER'S CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4.PROVIDE NEW HARDWARE TO BE: SCHLAGE, AL-SERIES, JUP STYLE, 626 FINISH LEVER HARDWARE. PIVOT HINGES-IVES, 7244F, US32D. PUSH/PULL-IVES, 8305 PULL PLATE, US26D W/ IVES 8300. PUSH-IVES, 8200 PUSH PLATE, US26D. KICKPLATE-IVES, 8400, US32D. OCCUPANCY DEADBOLT-SCHLAGE, B571 OR EQUAL. CLOSERS TO HAVE HOLD OPEN OPTION.5. P P = P U S H /P U L L S E T P = P U S H COORDINATE KEYING LOCKSETS WITH BUILDING MGMT. ALL EXISTING BUILDING DOORS TO BE KEYED ALIKE W/ STORAGE 112. OFFICE 115 TO BE KEYED SEPARATE. 6. D B = D E A D B O L T 2 '-0 " 3 A4.2 4 A4.2 5 A4.2T1 T8 T3 T7 T10 T4 T6 T5 T9 T2 T13 RESTROOM 2 '-7 " 3 " 2 '-1 0 " 3 '-6 " T9 SMOOTH PAINTED DRYWALL. RELOCATED SINK AND COUNTER ASSEMBLY. 6" TILE BASE. T7 RELOCATED MIRROR. RELOCATED WALL SCONCE. T5 T4 T6 5 '-2 " 3'-0" 2 '-1 0 " T1 T2 T8 SMOOTH PAINTED DRYWALL. EXISTING DECORATIVE TRIM. EXISTING PORCELAIN WALL TILE. T3 T10 T13 SOAP DISPENSER TOILET TISSUE DISP. NO.ITEM GRAB BAR - 42" MIRROR W/ TEMPERED GLASS T1 T3 GRAB BAR - 36" T2 T4 T5 T6 REST ROOM ACCESSORY SCHEDULE BOBRICK BOBRICK BOBRICK BRADLEY KOHLER CATALOG NUMBER B-6806 X 36 RELOCATE B-6806 X 42 RELOCATE MOUNTING HEIGHT MOUNT AT 36" AFF TO BOTTOM. STACK AT 22" A.F.F. AND 30" A.F.F. TO TOP. VERIFY IN FIELD. MOUNT AT 34" A.F.F. MOUNT AT 34" A.F.F. MANUFACTURER (OR APPROVED EQUAL) MOUNT IN COUNTER. PAPER TOWEL DISPENSER/TRASH B-543 K-1895-C-G BOBRICK B-43944 RELOCATE T7 T8 BOBRICK MOUNT AT 30" A.F.F. TO TOP.BOBRICKSANITARY NAPKIN DISPOSAL (WALL MOUNT)B-270 T9 T10 KOHLER 747 (XXX X 42") SEE ELEV. RELOCATE SEE MFG RECOMMENDATIONS. GRAB BAR - 18"B-6806 X 18 RELOCATE MOUNT AT 39" A.F.F. FAUCET FORTE K-10217 -4-G SINK/COUNTER/TRAP COVER BRADLEY TERREON LAV DECK 3071-1-BS-SHANK RT- RIVER-TEMP-DSWHT- LDTRAPS-BRKT VESSEL RIM HEIGHT 34" A.F.F. FURNISH W/ STRAIGHT RECTANGULAR BACK SPLASH. MOUNT IN COUNTER. K-4368 W/ K-4670-C SEAT PROVIDE SLOAN G2 OPTIMA PLUS 8111 BATTERY POWERED FLUSHOMETER.FLOOR MOUNTED TOILET KOHLERT13 7 '-0 " 2 " 3'-0"2"2" D1 3 9 " - 4 1 " 39" - 41" 1 '-6 " 3'-6" 1 '-1 0 " 8 " T8 T2 T1 T3 T10 T13 SCALE: 1/4" = 1'-0" 2 ENLARGED RESTROOM PLAN A4.2 SCALE: 1/2" = 1'-0" 4 RESTROOM ELEVATION A4.2 SCALE: 1/2" = 1'-0" 5 RESTROOM ELEVATION A4.2 SCALE: 1/4" = 1'-0" 1 DOOR SCHEDULE NOTES A4.2 SCALE: 1/2" = 1'-0" 3 RESTROOM ELEVATION A4.2 Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: B E A U T Y + G R A C E C a r m e l , I n d i a n a 4 6 0 3 2 C a r m e l C i t y C e n t e r - B l d g A 7 5 1 H a n o v e r P l a c e , S u i t e 1 5 9 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 6.05.2015 N PEDCOR DESIGN GROUP LS.1 Life Safety Plan CONSTRUCTION DOCUMENTS AJE MC6/04/2015 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 751 Hanover Place N R.6 Plaza P111 Color Concrete Paving.bpn PLAZA R A N G E L I N E R O A D BE BE BE PE BE BE PE & BE PE BE PLAZA BUILDING A BUILDING B BE SCALE: 1" = 20' 1 PHASE I LIFE SAFETY PLAN LS.1 WALL TYPES-FIRE RATINGS 1 HOUR RATED 2 HOUR RATED 3 HOUR RATED EGRESS PATH EXITS AND LOCATIONS BE PE PARKING EXIT BUILDING EXIT OP ORIGINATION POINT CARMEL CITY CENTER -PHASE 1 BUILDINGS 2. HORIZONTAL FIRE SEPARATIONS:  ● ASSEMBLIES SEPARATING THE GARAGE PARKING LEVEL AND FIRST FLOOR OF BUILDINGS ABOVE IS THREE HOURS(3HRS.) ● ASSEMBLIES SEPARATING THE GARAGE PARKING LEVEL AND PLAZA ABOVE IS ONE AND ONE HALF HOUR (1 1/2 HR.)  ● ASSEMBLIES SEPARATING THE FIRST FLOOR OF BUILDINGS AND SECOND FLOOR ABOVE IS TWO HOURS (2 HRS). CONSTRUCTION DESIGN RELEASE SHELL & CORE PROJECT NUMBER: 317796 RELEASE DATE: 06.19.07 2 HR. RATED. 2 HR. RATED. 1 HR. RATED. BEAUTY + GRACE BLDG A 1ST FLR Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: B E A U T Y + G R A C E C a r m e l , I n d i a n a 4 6 0 3 2 C a r m e l C i t y C e n t e r - B l d g A 7 5 1 H a n o v e r P l a c e , S u i t e 1 5 9 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 6.05.2015 N PEDCOR DESIGN GROUP LS.2 Life Safety Plan CONSTRUCTION DOCUMENTS AJE MC6/04/2015 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 751 Hanover Place BEAUTY + GRACE LIFE SAFETY & CODE SUMMARY PROJECT SUMMARY This project is a new tenant impr ovement pr oject known as BEAUTY + GRACE occupying 1,674 square f eet of the ground f loor of an existing Shell and Core pr oject known as Carmel City Center. The BEAUTY + GRACE pr oject occupies approximately three percent (3%) of the ground f loor area of a seven (7) story building. Beneath the ground f loor and separated with a 3-hour f ire r esistive assembly, is an unheated parking garage. The BEAUTY + GRACE pr oject is a Group M occupancy, and the construction type of this pr oject and the shell and core is I-B. The entire f acility is f ully protected by an automatic spr inkler system, and is surrounded by at least 30 f eet of yard depth. The BEAUTY + GRACE tenant is a Mercantile Occupancy providing a retail f acility f or Carmel r esidents. APPLICABLE CODES & STANDARDS Indiana General Administrative Rules (675 IAC 12) 2006 Indiana Building Code (IBC 2012) 2014 Accessibilit y-Indiana Building Code (ANSI A 117.1-2009) 2014 Minimum Design Loads f or Buildings (ASCE 7-2010) 2014 Indiana Plumbing Code, 2012 Edit ion 2012 Indiana Mechanical Code, 2014 Edit ion (IMC 2012) 2014 Indiana Elect rical Code, 2008 Edit ion (NFPA 70-2008) 2009 Indiana Fuel Gas Code, 2014 Edit ion (IFGC 2012) 2014 Indiana Fire Code (IFC 2012) 2014 Indiana Energy Conservat ion Code (ASHRAE 90.1 2007) 2010 NFPA 10-2010 Port able Fire Ext inguishers 2012 NFPA 13-2010 Inst allat ion of Fire Sprink ler Systems 2012 NFPA 72-2010 Nat ional Fire Alarm Code 2014 NFPA 90A- Inst allat ion of Air Condit ioning & Ventilating Systems 2015 NFPA 90B  — Inst allat ion of Warm Air Heating  & Air Condit ioning Systems    2015 ADA Standards f or Accessible Design 2010          OCCUPANCY CLASSIFICATIONS: BEAUTY + GRACE Tenant: Group M Building Shell & Cor e: Group A-2, A-3, B, M, R-2 Parking Garage: Group S-2 OCCUPANT LOAD BEAUTY + GRACE Total Gross Area 1,674 sq f t M Occupancy @ 30 sf /person 55 persons CONSTR UCTION TYPES: BEAUTY + GRACE Tenant: Type I-B Building Shell & Core: Type I-B Parking Garage: Type I-A BUILDING AREAS: BEAUTY + GRACE Tenant: 1,674 sf Shell & Core: (Ground Floor) 59,470 sf Shell & Core: (Total Building A) 309,587 sf Shell & Core: (Total Phase I) 508,691 sf FIRE RESISTANCE BEAUTY + GRACE Tenant & Shell & Core (Ground Floor ): Walls: All construction to be non-combustible Exit Passageways: 2 hours Fire walls: 2 hours Exit Access Corridors: 1 hour Floor: 3 hours (Separating B and S-2) Ceiling: 1 hour (Separating B and R-2) INTER IOR FINISHES BEAUTY + GRACE Tenant & Shell & Core (Ground Floor ): Vertical Exits & Passageways: Class B Exit Access Corridors Class C All Others Class C FIRE PR OTECTION 100% protection by an automatic sprinkler system per NFPA 13-1999 100% pr otection by a f ire alarm & annuciator system meeting NFPA 72-2002 Sprinkler f ire pump and backup power meeting NFPA 20-1999 Stairway pressurization meeting IBC 2008 and NFPA 92A-2002 ACCESSIBILITY REQUIR EMENTS All tenant restrooms comply with ICC/ANSI A 117.1-2009 PR EVIOUS IDHS APPROVALS Pr oject No. 317769 CDR Letter Foundation Release 04.25.06 Pr oject No. 317796 CDR Letter Standard R elease - Architectural & Structural 06.19.07 Pr oject No. 352730 CDR Letter Standard Release -Architectural Structural Electrical 07.19.11 RESTROOM 105 STORAGE/ OFFICE 104 RETAIL 100 DRESSING 102 HALL 109 D I S P L A Y 1 0 1 "Q U O T E " W A L L SUITE 159 1674 S.F. DRESSING 103 Stair SA6 Stair SA6 N P QP.5P QP.5P QP.5 17 16 17 16 17 16 SCALE: 3/16" = 1'-0" 1 Life Safety LS.2 LEGEND EGRESS PATH, POINT OF BEGINNING EGRESS PATH, POINT OF EXITING EGRESS PATH, DISTANCE TRAVELX'-X" 3 5 '-0 " 2 4 '-9 " Project Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: B E A U T Y + G R A C E C a r m e l , I n d i a n a 4 6 0 3 2 C a r m e l C i t y C e n t e r - B l d g A 7 5 1 H a n o v e r P l a c e , S u i t e 1 5 9 COPYRIGHT & OWNERSHIP OF DOCUMENTS State Release Set: 6.05.2015 N PEDCOR DESIGN GROUP SP.1 Specifications CONSTRUCTION DOCUMENTS AJE MC6/04/2015 PLAZA LEVEL KEY PLAN N.T.S. THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 751 Hanover Place ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY JUNCTION BOXES ARE NOT PERMITTED. TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE. SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT OWNER SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. FLOOR SLAB DOES NOT VARY BY MORE THAN ¼" IN 20'-0" NON- LIMITED TO APPLIANCES AND FILES, OWNER SHALL CONFIRM THAT FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. FRAMING CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED EXISTING CONSTRUCTION AND WALL TYPES. SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, TO BOTTOM OF FINISHED CEILINGS. TO TOP OF FINISHED FLOORS. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. TO FINISHED FACE OF DRYWALL. DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: PROCEEDING WITH CONSTRUCTION. REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO OWNER TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH-IN" LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO ELECTRICAL CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL PROVIDING PROPER ACCESS TO RECEPTACLES. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD OUTLETS, UNLESS OTHERWISE NOTED. DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. OWNER SHALL DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS COORDINATE WITH OTHER CEILING COMPONENTS. SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A DESIGN/BUILD DRAWINGS FOR FIRE PROTECTION, MECHANICAL, ELECTRICAL, AND THE OWNER IS TO PROVIDE A COMPLETE PACKAGE OF INSTALLATION AND INTER-SYSTEM COORDINATION OF MECHANICAL AND BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE DESIGN/BUILD CONTRACTOR SHALL ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTIN AND HVAC) AND PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS THE OWNER SHALL MAINTAIN FOR THE ENTIRE LENGTH OF THE PROJECT ADDITIONAL CHARGE TO THE PARTY AFFECTED. ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT THE OWNER SHALL BE HELD RESPONSIBLE FOR DAMAGES EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE OWNER THE OWNER SHALL PROTECT THE BUILDING PREMISES AND CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR ELEVATORS, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, LIGHT FIXTURES ( CATALOG CUTS ). HVAC THERMOSTATS, DIFFUSERS AND GRILLES ( PLANS AND CATALOG CUTS ). PAINT ( 8" X 11" DRAW DOWNS). PLUMBING (FIXTURES AND PLAN). FLOORING AND BASE ( COLOR SAMPLES ). CONCRETE MOCK-UP. SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6" X 6" ACOUSTICAL SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND "FURNISHED AND/OR INSTALLED" ITEMS. OWNER SHALL INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE THE OWNER SHALL COORDINATE AND SCHEDULE WORK BY OTHERS BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON-REGULAR WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN SUBMIT THE FOLLOWING INFORMATION: 1.8 1.7 1.6 AGENT. 1.5 .11 .10 .9 .8 .7 AWNINGS. .6 .5 PANEL ). .4 DOORS, FRAMES AND HARDWARE. .3 .2 .1 FOLLOWING ITEMS: 1.4 WORKMANSHIP. 1.3 1.2 1.1 GENERAL REQUIREMENTS1 MANUFACTURER'S RECOMMENDATIONS. 0.7 INTERPRETATION. REDUCIBLE ACRYLIC DRY FOG COATING. FINISH: 2 COATS #57601 UNI-GRIP-WB WATER1. PROVIDE SHOP DRAWINGS FOR OWNER;S APPROVAL PRIOR TO FABRICATION. FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI EQUIPMENT, PROVIDE FIRE-RETARDANT TREATED PLYWOOD PANELS, APA PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, STANDARDS. JURISDICTION. CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH PLYWOOD WITH FIRE-RETARDANT CHEMICALS TO COMPLY WITH AWPA FIRE-RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND C-D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32". CONTENT. .1 6.4 6.3 6.2 GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE WOOD AND PLASTIC REQUIRED TO COMPLETE WORK. METAL FABRICATIONS DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE RECORD SEPIA TO SERVE AS PART OF THE "AS-BUILT" SET. 6.1 6 5.1 5 2.11 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. REQUIREMENTS FOR HEAT-STRENGTHENED GLASS. GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 DOOR HARDWARE: SEE DOOR SCHEDULE ON SHEET A4.2. PLY PC-5 PARTICLE BOARD SOLID CORE. WOOD VENEER FACES: WALNUT. SEE FINISH LEGEND. INTERIOR DOORS: AWI SECTION 1300 "PREMIUM GRADE" PRE-MACHINED 5- 9.1 FINISHES9 8.4 8.3 8.2OWNER SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED SERVICES IN USE. OWNER SHALL SECURELY CAP AND/OR VALVE- OWNER SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURIING CONSTRUCTION OR EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING IN SCOPE OF CONTRACT. 2.10 2.9 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS NOTED TO BE REPAIRED. FINISHES. ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED ON EXISTING-CONSTRUCTION-TO-REMAIN, THOROUGHLY REMOVE DRAWINGS. BE INCLUDED. 2.8 2.6 2.5 2.4 PAINTED TO MATCH THE ADJACENT WALL SURFACE. STEEL - (ALUMINUM) FRAMES UNLESS NOTED OTHERWISE. COLOR TO BE INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD SNAP-ON TYPE "TREMCO ACRYLIC LATEX 834"; TREMCO, INC. "SONOLAC"; SONNEBORN BUILDING PRODUCTS "AC-20"; PECORA CORP. "CHEM-CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. ACRYLIC-EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS "PROGLAZE WHITE"; TREMCO CORP. 8.1 DOORS AND WINDOWS8 .4 .3 .2 .1 SURFACES: 7.2 .5 .4 "863 #345 WHITE"; PECORA CORP. "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. "DOW CORNING 786"; DOW CORNING CORP. FIXTURES AND JOINTS IN TOILET ROOMS: ONE-PART MILDEW-RESISTANT SILICONE SEALANT - AT COUNTERS, GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL WIDTH NOT TO EXCEED 1/8 U.O.N. JOINTS BEWTEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM STRAIGHT WITH NO DISTORTIONS. INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND .3 .2 .1 7.1 JOINT SEALERS7 OUTLETS. 6.11 6.10 6.9 CASEWORK: FURNISHINGS EQUIPMENT SEMI RECESSED, DUO-PANEL, FIELD PAINTED. BUILDING STANDARD, PROVIDE JL INDUSTRIES "AMBASSADOR" SERIES, FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO ACRYLIC DRY FOG FLAT FINISH: REDUCIBLE ACRYLIC DRY FOG COATING FINISH: 2 COATS #57601 UNI-GRIP-WB WATER ACRYLIC DRY FOG FLAT FINISH: SEMI-GLOSS FINISH FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC LATEX PRIMER. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC ACYRLIC SEMI-GLOSS ENAMEL FINISH: SEMI-GLOSS ENAMEL. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC LATEX PRIMER. A. NON-FERROUS STRUCTURE:4. 1. A. FERROUS STRUCTURE:3. 2. 1. A. NON-FERROUS METAL:2. 2. .1 PRIMER: 1 COAT #41702 METALCLAD ACRYLIC ACRYLIC SEMI-GLOSS ENAMEL FINISH: FOR THE VARIOUS SUBSTRATES, AS INDICATED. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 1. A. FERROUS METAL:1. .1 REINSTALL SUCH ITEMS. 9.11 12.1 12 11 10.1 YORKTOWNE CABINETS.3 MERILLAT INDUSTRIES, INC..2 IMPERIAL CABINET CO., INC..1 FOLLOWING: MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE TENANT, INSTALLED BY OWNER, UNLESS NOTED OTHERWISE. GN.10 GN.9 CLOSE-IN OF WALLS. GN.8 GN.7 OBSERVATION. GN.6 WITH CONSTRUCTION. LATEX TEXTURE COATING-SAND FINISH (WET AREAS) SPECIALTIES PRECAST CONCRETE: INSTALL CARPET TILES USING ASHLAR VERTICAL METHOD. INSTALL BROADLOOM CARPET BY DIRECT GLUE. 10 YEARS AATCC 134 AATCC 16E ASTM C423 ASTM E662 ASTM E84 ASTM 2859 .2 .1 WARRANTY: STATIC RESISTANCE: FADE RESISTANCE: SOUND ABSORPTION: SMOKE DENSITY: SURFACE BURNING: FLAMMABILITY: 10 2. 1. CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING SURFACE VARIATION OF ¼" IN 10 FEET, NON-CUMULATIVE. HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS STANDARDS: 9.8 9.7 .2 .1 A. 13. 2. TEXTURE COATING. FINISH: 1 COAT #44101 DEV-VO-TEX LATEX LATEX HOUSE PAINT PRIMER. PRIMER: 1 COAT #1502 WONDER-SHIELD ACRYLIC GN.5 OTHERWISE. GN.4 GN.3 D. C. B. A. GN.2 LATEX SATIN ENAMEL. FINISH: 2 COATS #35XX WONDER TONE ACYRLIC GN.1 GENERAL NOTESGN CONSTRUCTION. 15/16.13 FOR SPECIFIC LOCATION. 15/16.12 15/16.11 WHITE. NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND RESPONSIBILITIES OF THE OWNER WHICH MAY BE PARAPHRASED THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1997 EDITION, 0.6 GOVERN THE WORK. 0.5 SPECIFIED CAPACITIES OF THE EQUIPMENT. 0.4 PROJECT. 0.3 RULES AND REGULATIONS. 0.2 OWNER'S RESPONSIBILITY. 10.1 WORKMANSHIP. 3.14 3.7 3.3 PROCEEDING WITH CONSTRUCTION. 3.2 AS FOLLOWS: 0.1 CONTRACT CONDITIONS0 SPECIFICATIONS AND GENERAL NOTES WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR WORK. EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE 2.3 2.2 2.1 DEMOLITION THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL REQUIREMENTS. EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT HOISTING, CARTING, ELEVATOR SERVICE, STANDARD AND OVERTIME 2 1.12 1.11 OPERATING FOR TEN DAYS. WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH OR EQUAL. SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF MANUFACTURED BY KNAPE & VOGT. HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS WITH POSITIVE STOP AND LOCKOUT POSITION, WITH DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES 6.8 6.7 .5 .4 MANUFACTURED BY STANLEY. MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MOCKETT DP78-26M. PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, BY GRASS OR EQUAL. HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES" CABINET HARDWARE SCHEDULE: SEMI-EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP-28. (0.028" NOMINAL THICKNESS); EDGES: GP-28 (0.028" NOMINAL GP-50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP-28 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: .3 .2 .1 .3 .2 THICKNESS). .1 THE OWNER SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 1.10 1.9 .4 .3 .2 AFFECT THE CONTRACT SUM AND CONTRACT TIME. ACCOMMODATE THE SUBSTITUTION. PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400B FOR ELECTRICAL OR DATA OUTLET LOCATIONS. PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL NEMA LD 3 AND GP-50 (0.050" NOMINAL THICKNESS). COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH 6.6 .2 SURFACES. .1 6.5 ACRYLIC LATEX SATIN ENAMEL FINISH: GYPSUM WALLBOARD: STAIN-VARNISH RUBBED FINISH: ACRYLIC LATEX SEMI-GLOSS ENAMEL FINISH: ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALL ZINC TRANSITION STRIP BETWEEN CARPET AND TILE TO BE SCHLUTER, SCHENE. INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN REFLECTED CEILING PLAN SHALL GOVERN. IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL RESILIENT FLOORING:9.6 .1 CASED OPENING UNLESS NOTED OTHERWISE. 9.5 UNLESS NOTED OTHERWISE. .2 1. A. 10. 4. 3. COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM CORNERS WITH COVE SHAPES, JOINTS TO MATCH UP. OUTSIDE CORNERS WITH CORNER SHAPES; WALL-TO-FLOOR INSIDE CORNERS SQUARE WITH FULL OR CUT FIELD TILES; PROVIDE FACTORY-MADE CORNER AND TRIM SHAPES. MAKE PORCELAIN TILE: INSTALL TILE IN ACCORDANCE WITH TILE COUNCIL OF .1 DAMAGED OR SOILED TILES. 9.4 .1 AMERICA GUIDELINES. 9.3 2. 1. B. 2. 1. A. WOOD:8. 2. 1. A. CONCRETE:7. PRIMER-SEALER. PRIMER: 1 COAT #50801 WONDER TONES LATEX ALKYD SATIN VARNISH. FINISH: 2 COATS #4600 WONDER WOODSTAIN QUICK DRY SEALER. SEALER: 1 COAT #4900 WONDER WOODSEALER ALKYD STAIN. 15/16.10 15/16.9 INSTALLATION SHALL OCCUR. 15/16.8 15/16.7 EQUIPMENT. 15/16.6 OWNER'S AGENT. STAIN: 1 COAT #96XX WONDER WOODSTAIN PASTE WOOD FILLER (OPEN GRAIN WOODS). FILLER: 1 COAT #4800 WONDER WOODSTAIN SEMI-GLOSS ENAMEL. FINISH: 2 COATS #83XX MIRROLAC-WB ARCYLIC PRIMER-SEALER. PRIMER: 1 COAT #51701 WONDER-PRIME LATEX LATEX SATIN ENAMEL. FINISH: 2 COATS #35XX WONDER TONES ACRYLIC PURPOSE PRIMER-SEALER. PRIMER: 1 COAT #51801 KILSTAIN-WB ALL- 15/16.5 15/16.4 15/16.3 CERTIFIED ENGINEER. 15/16.2 COMPLY WITH ASTM C 840 STANDARD SPECIFICATION FOR APPLICATION AND FINISHING OF GYPSUM BOARD; GA 214 RECOMMENDED LEVELS OF GYPSUM BOARD FINISH; AND GA216-2000 APPLICATION AND FINISHING OF GYPSUM BOARD. WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE "X" TAPERED .1 9.2 ELECTRICAL SYSTEMS. 15/16.1 MECHANICAL AND ELECTRICAL15/16 FIRE EXTINGUISHERS (CATALOG CUTS). WARRANTY: LIFETIME WARRANTY ON ALL ARCHITECTURAL FLUSH WOOD DOORS, INCLUDING THOSE DOORS WITH VIEW PANELS AND LOUVERS. PROVIDE DRAFT COPY OF WARRANTY WITH SUBMITTALS. MANUFACTURER STANDARD FACTORY PRE-FINISHED WITH PERFORMANCE EQUAL TO AWI STANDARDS SECTION 1500 CONVERSION VARNISH SYSTEM; A TWO-PART CATALYZED SYSTEM FOR PREMIUM GRADE PER AWI 1500-T-14. COLOR TO BE SELECTED BY THE ARCHITECT. .2 .1 DRYWALL FINISHING: PROVIDE GYPSUM WALLBOARD MINIMUM FINISH LEVELS MEETING THE CRITERIA ESTABLISHED IN GA 214 AS FOLLOWS: LEVEL 1 - GYPSUM WALLBOARD PERMANENTLY CONCEALED FROM VIEW. LEVEL 2 - GYPSUM WALLBOARD BEHIND AN APPLIED WALLCOVERING, AND WALLS AND CEILINGS IN MECHANICAL AND EQUIPMENT ROOMS. LEVEL 4 - GYPSUM WALLBOARD ON INTERIOR WALLS FOR ALL TENANT SPACES. LEVEL 5 - GYPSUM WALLBOARD ON ALL FINISHED CEILINGS AND ALL COMMON AREA WALLS. .2 SEE EQUIPMENT PLAN FOR SPECIFICATION AND BUILDING REQUIREMENTS.11.2 MEP SHELL SPECIFICATIONS: IN ADDITION TO THE NOTES BELOW, THE PREVIOUSLY ISSUED SPECIFICATION FOR DIVISION 15 AND 16 SHALL BE APPLICABLE TO ALL WORK UNDER THESE CONTRACT DOCUMENTS. COPIES OF THE SPECIFICATION ARE AVAILABLE FROM THE ARCHITECT (PEDCOR DESIGN GROUP) AND THE OWNER. 15/16.0 FIRE PROTECTION (PLAN). ELECTRICAL (PLAN). INSTALL ZINC TRANSITION STRIP BETWEEN VINYL AND TILE TO BE SCHLUTER, RENO-U..2 INSTALL VINYL TRANSITION STRIP BETWEEN VINYL AND CARPET TO BE JOHNSONITE CTA-40-C..3 INSTALL TRANSITION BETWEEN RESTROOM FLOOR & WALL TILE TO BE SCHLUTER DILEX-AHK..4 PROVIDE FULL COVERAGE MORTAR APPLICATION (TCNA DETAIL F-125 FULL COVERAGE) IN WOMEN'S RESTROOM, KITCHEN, PREP, AND DISHES USING TEC, 1FLEX CRACK ISOLATION MORTAR. CONTACT MARC MULARONI 330.283.3997 .2 PROVIDE SOFT JOINTS IN THE TILE WORK PER TCNA EJ-171 DETAILS. REFERENCE 7/A4.5.3 MITER TILE AT OUTSIDE CORNERS..4