HomeMy WebLinkAbout49 E0.1.PDFABBREV. DES RIPTION ABBREV. DESCRIPTION
C
A or AMP AMPERE INCL INCLUDE
AC ALTERNATING CURRENT ISG ISOLATED GROUND SURGE GUARD
A/C AIR CONDITIONING JB JUNCTION BOX
ACU AIR CONDITIONING UNIT KEC KITCHEN EQUIPMENT CONTRACTOR
ADD ADDITION KVA KILOVOLT AMPERE
AFF ABOVE FINISHED FLOOR KVAR KILOVOLT AMPERE REACTIVE
AH U AI R HAN D LI N G U N IT KW K I LOWATT
AIC AMPERE INTERRUPTING CAPACITY LAB LABORATORY
AL ALUMINUM LB POUND
APPROX APPROXIMATELY LS LIFE SAFETY
ARCH ARCHITECT LTG LIGHTING
ATS AUTOMATIC TRANSFER SWITCH MATV MASTER ANTENNA TELEVISION
AUTO AUTO MATI C MAX MAX I M U M
AVG AVERAGE MC MECHANICAL CONTRACTOR
BL BUILDING LINE MCB MAIN CIRCUIT BREAKER
BLDG BUILDING MCC MOTOR CONTROL CENTER
C CONDUIT MDP MAIN DISTRIBUTION PANEL
°C DEGREES CELSIUS MECH MECHANICAL
CAB CABINET MIN MINIMUM
CB or C/B CIRCUIT BREAKER MISC MISCELLANEOUS
CCTV CLOSED CIRCUIT TELEVISION MLO MAIN LUGS ONLY
C LG C EI LI N G MTD M 0 U NTED
COMM COMMUNICATION OFCI OWNER FURN.—CONT. INSTALLED
COMP COMPRESSOR OF01 OWNER FURNISHED—OWNER INSTALLE
CONC CONCRETE OR OPERATING ROOM
CONST CONSTRUCTION PB PUSHBUTTON
CONTR CONTRACTOR PH or � PHASE
CT CURRENT TRANSFORMER PIV POST INDICATOR VALVE
CU COPPER PNL PANELBOARD
DEPT DEPARTMENT PL PILOT LIGHT
DIST DISTRIBUTION PREFAB PREFABRICATED
DWG DRAWING PWR POWER
EC ELECTRICAL CONTRACTOR RECEPT RECEPTACLE
EF EXHAUST FAN REF/REFR REFRIGERATOR
ELEC ELECTRIC RPM REVOLUTION PER MINUTE
ELEV ELEVATO R S HT S H EET
EMER EMERGENCY SPEC SPECIFICATIONS
ENCL ENCLOSURE SQ SQUARE
EQUIP EQUIPMENT STD STANDARD
EWC ELECTRIC WATER COOLER SW SWITCH
EXH EXHAUST SWBD SWITCHBOARD
°F DEGREES FAHRENHEIT SWGR SWITCHGEAR
FA FIRE ALARM TCC TEMP. CONTROL CONTRACTOR
FAAP FIRE ALARM ANNUNCIATOR PANEL TB TERMINAL BOX
FACP FIRE ALARM CONTROL PANEL TEMP TEMPERATURE
FCU FAN COIL UNIT TV TELEVISION
FIXT FIXTURE TYP TYPICAL
FLUOR FLUORESCENT U/C UNDERCABINET/UNDERCOUNTER
FVR FI LMVI EWER U H U N IT H EATER
G or GND GROUND UV UNIT VENTILATOR
GALV GALVAN I Z ED V VO LT
GC GENERAL CONTRACTOR VFD VARIABLE FREQUENCY DRIVE
GFCI GROUND FAULT CIRCUIT INTERRUPTEI�P VIDEO PROJECTOR
GFI GROUND FAULT INTERRUPTER VSD VARIABLE SPEED DRIVE
HID HIGH INTENSITY DISCHARGE VSD VARIABLE SPEED DRIVE
H OA HAN D— 0 FF—AUTO MATI C W/ W ITH
HP HORSEPOWER W/0 WITHOUT
HPS HIGH PRESSURE SODIUM WP WEATHERPRO F
XFMR TRANSFORMER
SYMBOL DESCRIPTION
� PHASE
CONDUCTORS
F60 � GROUND QUANTITY OF CONDUCTORS OR CABLES IN CONDUIT
SWITCH LEG F60 INDICATES FEEDER SIZE. SEE SCHEDULE
NEUTRAL
CONDUIT TURNED UP
� CONDUIT TURNED DOWN
� JUNCTION OR PULL BOX
Q FLOORBOX SEE NOTES FOR DESCRIPTION
DEVICE HEIGHT ABOVE FLOOR
TO BOTTOM OF DEVICE
RECEPTACLES, SURFACE RACEWAY, 18" — GENERAL AREAS
VOICE/DATA OUTLETS, TV OUTLETS 18" — MECHANICAL EQUIPMENT ROOMS
2" — ABOVE BACKSPLASH TOP TO BOTTOM
36" — BEHIND DOMESTIC REFRIGERATORS
36 8c 24" — BEHIND DOMESTIC WASHER AND
52" — WALL M 0 U NTED TELEP H 0 N E 0 UTLET
TOGGLE SWITCHES 46"
RECESSED MOTOR CONTROLLERS 46"
ELECTRIC PANELS, TERMINAL CABINETS 72" TO TOP OF BOX OR TUB
MAN UAL P U LL STATI O N 46"
FIRE HORN/STROBE 80"
SYMBOL DESCRIPTION
------------------------------------------ LI G HT/S C R EEN ED CO NTI N U 0 U S LI N ES I N D I CATE EX I STI N G TO R EMAI N
--- HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED
HEAVY CONTINUOUS LINES INDICATE NEW WORK
DRYERS
SYMBOL DESCRIPTION
X 2 X=FIXTURE TYPE 2=CIRCUIT NUMBER c=SWITCH LEG
O� , ,
•
O
O>
�
L1
F — FLUORESCENT
FLUORESCENT TYPE FIXTURE
O NORMAL POWER
• "EM" AN D"N L" WITH BATTERY BAC K— U P
DOWNLIGHT TYPE FIXTURE
WALLWASH DOWNLIGHT TYPE FIXTURE
WALL M 0 U NT FI XTU R E
DIMMING SYSTEM LIGHTING CONTROL STATION "L1 "
TRACK LIGHTING
�'° LI G HT PO LE
STAN D BY LI G HTI N G— BATTE RY U N IT 0 N LY
STANDBY LIGHTING — BATTERY UNIT WITH LIGHT HEADS
STANDBY LIGHTING — REMOTE LIGHT HEAD WALL MOUNT
� )
EXIT LIGHT (MOUNTED ON CEILING)
EXIT LIGHT SURFACE MOUNTED ON WALL
� )
EXIT LIGHT WITH DIRECTIONAL ARROWS
OCCUPANCY SENSOR
SYMBOL DESCRIPTION
.
...
.
1
O
1
DUPLEX RECEPTACLE
DUPLEX RECEPTACLE — EMERGENCY CIRCUIT
QUADRAPLEX RECEPTACLE — NORMAL CIRCUIT
AS FO LLOWS: )
QUADRAPLEX RECEPTACLE — EMERGENCY CIRCUIT
SIMPLEX RECEPTACLE — NORMAL CIRCUIT
� SIMPLEX RECEPTACLE — EMERGENCY CIRCUIT ("X" DENOTES
X AS FOLLOWS:
)
NONE — 20 AMP, 125VAC
GFI — 20 AMP, 125VAC, GROUND FAULT INTERRUPTER TYPE
HM — 20 AMP, 125VAC, HORIZONTAL MOUNT TYPE
IG — 20 AMP, 125VAC, ISOLATED GROUND TYPE
S— 20 AM P, 125VAC, S U RG E G UAR D P ROTECTI O N TYP E
ST — 20 AMP, 125VAC, SAFETY TYPE
WP — 20 AMP, 125VAC, WEATHERPROOF TYPE
� SPECIAL RECEPTACLE — NORMAL CIRCUIT (SEE DRAWINGS AND
SPECIFICATIONS
e SPECIAL RECEPTACLE — EMERGENCY CIRCUIT (SEE DRAWINGS
AND SPECIFICATIONS)
S
3
S
4
S
P
S
k
0
0 S
a a
�
TOGGLE SWITCH — 20 AMP, 120/277VAC
TOGGLE SWITCH — 3—WAY
TOGGLE SWITCH — 4—WAY
TOGGLE SWITCH — PILOT LIGHT
TOGGLE SWITCH — KEY OPERATED
INDIVIDUAL LIGHT DIMMER
LETTER DESIGNATION INDICATES SWITCH LEG
FLOOR BOX OR PEDESTAL RECEPTACLE (SEE NOTES)
SYMBOL DESCRIPTION
N CABLE TELEVISION JACK
SYMBOL DESCRIPTION
S LOUDSPEAKER — CEILING MOUNTED
"BLANK" — PAGING SPEAKER
� VOLUME CONTROL
S LOUDSPEAKER — WALL MOUNTED
SYMBOL DESCRIPTION
M MANUAL SENDING STATION
F AUTOMATIC FIRE DETECTION DEVICE ("X" DENOTES AS FOLLOWS:)
X
NONE — PHOTOELECTRIC TYPE
B— BEAM TYPE
P — PHOTOELECTRIC TYPE
R — RATE—OF—RISE TYPE
T — TEMPERATURE TYPE
FSD — FIRE/SMOKE DAMPER
D AUTOMATIC DUCT DETECTOR ("X" DENOTES AS FOLLOWS:)
x
NONE — IONIZATION TYPE
P — PHOTOELECTRIC TYPE
T
L
S
S
S
S
S
S
H
H
H
H
C
C
B
B
V
R
U
A
S
TPX
SYMBOL
D
K
CR
OQ
SYMBOL
�
v
�
WA
❑
D U CT D ETECTO R R E M OTE TEST STATI 0 N
REMOTE DETECTOR ALARM LAMP
SPRINKLER SYSTEM FLOW SWITCH
SPRINKLER SYSTEM TAMPER SWITCH
P AK R— IN PR TI N
S E E S GLE OJEC 0
SPEAKER — SINGLE PROJECTION WITH VISUAL ALARM SIGNAL
SPEAKER — DOUBLE PROJECTION
SPEAKER — DOUBLE PROJECTION WITH VISUAL ALARM SIGNAL
HORN — SINGLE PROJECTION
HORN — SINGLE PROJECTION WITH VISUAL ALARM SIGNAL
HORN — DOUBLE PROJECTION
HORN — DOUBLE PROJECTION WITH VISUAL ALARM SIGNAL
CHIME
CHIME WITH VISUAL ALARM SIGNAL
BELL
BELL WITH VISUAL ALARM SIGNAL
VISUAL ALARM SIGNAL DEVICE
DOOR RELEASE DEVICE — FIRE ALARM ACTIVATED
DOOR UNLOCK OPEN DEVICE — FIRE ALARM ACTIVATED
�
FIRE ALARM SYSTEM ADDRESSABLE RELAY
DESCRIPTION
BRANCH PANELBOARD AND CABINET — RECESSED MOUNT
BRANCH PANELBOARD AND CABINET — SURFACE MOUNT
DISTRIBUTION PANELBOARD AND CABINET — RECESSED MOUNT
DISTRIBUTION PANELBOARD AND CABINET — SURFACE MOUNT
DISCONNECT SWITCH — FUSED
DISCONNECT SWITCH — NON—FUSED
MOTOR CONTROLLER
COMBINATION MOTOR CONTROLLER
HORSEPOWER RATED MANUAL MOTOR STARTER TOGGLE SWITCH
WITH THERMAL OVERLOAD PROTECTION ("X" DENOTES AS
FOLLOWS:)
NONE SINGLE POLE
2-2POLE
3-3POLE
HORSEPOWER RATED MANUAL MOTOR STARTER TOGGLE SWITCH
WITH THERMAL OVERLOAD PROTECTION WITH PILOT LIGHT
("X" DENOTES AS FOLLOWS:)
NONE — SINGLE POLE
2-2POLE
3-3POLE
DESCRIPTION
DOOR SECURITY SYSTEM DOOR CONTACT
DOOR SECURITY SYSTEM KEYPAD
DOOR SECURITY SYSTEM CARD READER / PROX READER
CAM ERA
DESCRIPTION
VO I C E O N LY O UTLET
V0 I C E AN D DATA 0 UTLET
DATA 0 UTLET
CEILING MOUNTED WIRELESS ACCESS OUTLET LOCATION
�ENERAL PROJECT NOTES:
(THESE NOTES APPLY TO ALL E-DRAWINGS)
A. ALL WORK INDICATED ON THE ELECTRICAL DRAWINGS IS NEW ANQ BY THIS CONTRACTOR UNLESS OTHERWISE
INDICATED.
B. REFER TO ARCHITECTURAL, CIVIL, MECHANICAL AND PLUMBING DRAWINGS AND ALL SPECIFICATIONS FOR
ADDITIONAL ELECTRICAL WORK NOT INDICATED ON THE ELECTRICAL DRAWINGS OR IN THE ELECTRICAL
SPECIFICATIONS.
C. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID ALL ALLOWANCES, FEES AND COSTS TO COMPLETE THIS
P ROJ ECT.
D. THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL REQUIRED LABOR ANQ PROVIDE ALL MATERIAL, EQUIPMENT
INCLUDING ALL CONTRACTOR'S SERVICES NECESSARY TO COMPLETE INSTALLATION OF THE REQUIRED SYSTEMS IN
FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED INSTALLATION SHALL BE
FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR COMPLETE AND
OPERATIONAL SYSTEMS.
E. PROVIDE ALL DISCONNECTS, STARTERS, OUTLETS, RECEPTACLES, WIRING, CONDUIT, ETC. AS REQUIRED TO
PROPERLY CONNECT ALL EQUIPMENT. FIELD VERIFY REQUIREMENTS WITH APPROVED SUBMITTALS, NAME PLATES,
EQUIPMENT SUPPLIERS, ETC. PRIOR TO INSTALLATION. ADJUST SIZE OF DISCONNECTS, BREAKERS, WIRING, ETC.
AS REQUIRED BY COQES TO COMPLETE THE ELECTRICAL INSTALLATION.
F. THE EXACT LOCATION OF LIGHT FIXTURES SHALL BE GOVERNED BY THE AR�HITECTURAL DRAWINGS UNLESS
4THERWISE N4TED. THE ELECTRICAL DRAWINGS SHALL INDICATE THE TYPE AND CIRCUITING INFORMATION OF
THE FIXTURES.
G. COORDINATE EXACT LOCATIONS OF LIGHTING FIXTURES, WIRING DEVICES, OUTLETS, ETC. WITH ARCHITECTURAL
REFLECTEQ CEILING PLANS, SCHEDULES, ELEVATIONS, DETAILS AND APPROVED SHOP DRAWINGS PRIOR TO
ROUGH-IN AND ADJUST ACCORDINGLY.
H. ALL DIMENSIONS SHOWN SHALL BE FROM THE FINISHED FLOOR TO THE BOTT4M OF EQUIPMENT, DEVICE OR
OUTLET BOX, UNLESS OTHERWISE NOTED.
I. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRED TO MINIMIZE SOUND
TRANSMISSION.
J. ALL CIRCUITS ARE 20 AMP, SINGLE-P�LE UNLESS OTHERWISE INDICATED.
K. MINIMUM WIRE SIZE SHALL BE 12 AWG UNLESS OTHERWISE INDICATED. MINIMUM CONDUIT SIZE SHALL BE 3/4"
UNLESS OTHERWISE INDICATED.
L. ALL CIRCUITS SHALL CONTAIN A GROUND WIRE.
M. EACH NEUTRAL WIRE SHALL BE DEDICATED TO A CIRCUIT. DO NOT SHARE NEUTRAL WIRING WITH MULTIPLE
CIRCUITS.
N. PROVIDE #1Q WIRING FOR ALL 12Q VOLT, 20 AMP CIRCUITS EXCEEDING 75 FEET IN LENGTH AND FOR ALL 277 VOLT,
20 AMP CIRCUITS EXCEEDING 175 FEET IN LENGTH UNLESS OTHERWISE NOTED WITH LARGER WIRING.
O. PROVIDE ONE HOUR UL FIRE RATED ENCLOSURE OVER ALL LIGHT FIXTURES THAT PENETRATE THE FIRE RATED
CEILINGS. PROVIDE UL LISTED ONE HOUR ENCLOSURE. ALLOW MINIMUM THREE INCHES OF SPACE MINIMUM
BETWEEN FIXTURE ENCLOSURE/HOUSING AND FIRE RATED BOX.
P. INTERIOR COMMON AREAS, SUCH AS CORRIDORS, AND EXTERIOR LIGHTING WILL BE CONTROLLED VIA RELAY
SYSTEM WITH ASTR�NOMICAL CLOCK AND DIGITAL OVERRIDE CONTROL STATIONS SIMILAR TO LUTR4N
SOFTSWITCH SYSTEM. REFER TO SPECIFICATIONS AND SCHEDULES FOR ADQITIONAL INFORMATION.
Q. WHERE OCCUPANCY SENSORS ARE INDICATED ON PLANS, THE ENTIRE ROOM SHALL BE COVERED.
MANUFACTURER IS RESPONSIBLE FOR SENSOR LAYOUT. ADDITIONAL SENSORS REQUIRED FOR LACK OF
COVERAGE SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. PROVIDE QUANTITY AS REQUIRED.
CEILING AND WALL MOUNTED SENSORS SHALL BE DUAL TECHNOLOGY TYPE. SENSORS SHALL INCLUDE ALL POWER
SUPPLIES AND RELAYS NECESSARY TO CONTROL LIGHT FIXTURES IN R40M/AREA. SENSORS SHALL OPERATE IN
"VACANCY" MODE - MANUAL ON/AUTO OFF. ACCEPTABLE MANUFACTURERS ARE: HUBBELL, SENSOR SWITCH,
LEVITON, PHILIPS.
R. VERIFY EXACT LOCATI4N OF ALL TELECOMMUNICATION OUTLETS WITH THE OWNER IN THE FIELD PRIOR TO
ROUGH-IN.
+ ��
S. INSTALL ALL RECEPTACLES AND TELECOM OUTLETS AT 18 A.F.F. UNLESS OTHERWISE N TED.
T. INSTALL SMOKE DETECTORS A MINIMUM OF 3 FEET AWAY FROM AIR VENTS.
U. PROVIDE BOXES WITH CONDUIT STUBBED INTO ACCESSIBLE CEILING SPACE FOR ALL COMMUNICATIONS DEVICES
SUCH AS FIRE ALARM, SECURITY, DOOR CONTROL, VOICE/DATA, VIDEO, ETC. UNLESS 4THERWISE NOTED.
V. COLOR OF DEVICES INSTALLED IN CEILINGS AND CLOUDS SHALL BE SELECTED BY ARCHITECT.
W. PROVIDE PULL-WIRE IN ALL EMPTY CONDUITS.
X. PROVIDE BOXES FOR ALL COMMUNICATIONS DEVICES SUCH AS FIRE ALARM, SECURITY, DOOR CONTROL,
VOICE/DATA, VIDEO, ETC. UNLESS 4THERWISE NOTED.
Y. PROVIDE PLASTIC BUSHINGS 4N THE ENDS OF ALL COMMUNICATION SYSTEMS CONDUIT UNLESS OTHERWISE
NOTED.
Z. IN LOCATIONS WHERE MULTIPLE LIGHTING SWITCHES ARE SHOWN, INSTALL THESE LIGHTING SWITCHES IN ONE
MULTI-GANG BOX.
AA. FIELD VERIFY EXACT LOCATION OF LIGHTING FIXTURES FIRE ALARM DEVICES SECURITY SYSTEM DEVICES ETC. IN
ROOMS THAT CONTAIN EXPOSED DUGTWORK AND PIPING AND RELOCATE AS RE UIRED BY THE ENGINEER.� �
Q
AB. WHERE SPACE ALLOCATIONS WITH REGARD TO ELECTRICAL EQUIPMENT ARE NOT ADEQUATE FOR THE SPECIFIED
ELECTRICAL EQUIPMENT; THE ENGINEER SHALL BE CONSULTED BEFORE ORDERING THE EQUIPMENT AND BEFORE
ANY INSTALLATION IS PERFORMED.
AC. CUTTING AND PATCHING, AND CORE DRILLING FOR ELECTRICAL WORK SHALL BE THE RESPONSIBILITY OF THE
ELECTRICAL CONTRACTOR.
AD. ALL EXTERIOR DUPLEX RECEPTACLES SHALL BE GFCI WITH "WHILE-IN-USE" WEATHER PROOF COVERS.
AE. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EQUIPMENT ELECTRICAL DISCONNECTING MEANS
PROVIQED BY THE ME�HANI�AL AND PLUMBING CONTRACTORS.
AF. GFCI CIRCUIT SHALL BE INSTALLED SUCH THAT GFCI RECEPTACLE SHALL ONLY TRIP ITSELF AND DOES NOT TRIP OR
DISCONNECT POWER ON ANY OTHER RECEPTACLE.
AG. DEVICE LOCATIONS AND RACEWAY ROUTING SHOWN ON DRAWINGS IS DIAGRAMMATIC. CONTRACTOR SHALL
VERIFY ALL CONDITIONS PRIOR TO STARTING CONSTRUCTION.
AH. CONTRACTOR SHALL INCLUDE IN HIS BID PROVIDING COMPLETE THE FOLLOWING ITEMS TO BE USED AT THE
OWNERS DISCRETION AT ANY POINT IN THE PROJECT INCLUDING AFTER WALLS AND CEILINGS ARE COMPLETE AND
FINISHED AT LOCATIONS TO BE DETERMINED BY THE OWNER. ALL CUTTING AND PATCHING OF INTERIOR WALLS
AND FINISHES SHALL BE INCLUDED IN THE CONTRACTORS BID (BRICK AND POURED CONCRETE EXCLUDED} FOR
EACH OF THESE ITEMS. TURN ANY UNUSED DEVICES OR EQUIPMENT OVER TO OWNER AT PROJECT COMPLETION.
REFER TO SPECIFICATIONS FOR ADDITIONAL ITEMS.
a. TWENTY {20} 20A, 120V DUPLEX RECEPTACLES INCLUDING UP TO 50 FEET OF RACEWAY AND ASSOCIATED
WIRING AT EACH L�CATION.
b. FOUR {4} VOICE/QATA OUTLET BOXES IN�LUDING UP TO TWENTY FEET OF RACEWAY FOR EACH OUTLET BOX.
c. TWO {2} SMALL {20A, 120V} MOTOR / EQUIPMENT CONNECTIONS COMPLETE INCLUDING UP TO 50 FEET OF
RACEWAY, TOGGLE DISCONNNECT AND ASSOCIATED WIRING AT EACH L4CATION.
d. TWO (2} FIRE ALARM HORNNISUAL OR VISUAL ONLY DEVICE OUTLET BOXES INCLUDING UP TO TWENTY FEET
OF RACEWAY FOR EACH OUTLET BOX.
e. TWO (2} EXIT SIGN INSTALLED COMPLETE AND WIRED TO APPROPRIATE LIFE SAFETY PANEL LIGHTING
CIRCUIT.
g. TWO (2} SECURITY SYSTEM ROUGH-IN SINGLE-GANG BOXES EACH INCLUDING UP TO 10 FEET OF RACEWAY AT
EACH LOCATION.
AJ. CONTRACTOR SHALL COORDINATE WITH THE LOCAL POWER COMPANY AND PROVIDE NEW PERMANENT
ELECTRICAL SERVICE TO THE BUILDING. VERIFY WHAT THE LOCAL POWER COMPANY WILL FURNISH AND INSTALL
AND WHAT THIS CONTRACTOR SHALL FURNISH AND INSTALL. THIS CONTRACTOR SHALL PROVIDE ALL WORK
INCLUDING LABOR AND MATERIALS NOT PROVIDED BY THE LOCAL POWER COMPANY TO PROVIDE THE NEW
PERMANENT ELECTRICAL SERVICE. THIS CONTRACTOR SHALL PAY ALL FEES CHARGED BY THE LOCAL POWER
COMPANY TO PROVI DE THE NEW SERVICE.
�;; ECTOR CONSULTING ��c
,r';';;�":'' Meclaanical & E/ectrica/ Engineering
�;;nn
,�,,;.
�!lir
''�" ' �OD5 Narth Senate Avenue
��r
lndianapo/is, lndiana 46202
ph. 3 �7.632.4444
fax 397.fi32.4960
��������� � �����,�%i
��� C`� 000000�� A��i
�� `�o�°° '°�J' 1/ �i
��� G °° °°/l� ��
..
�Qo p � o! fi �
� o �v O ,i � v� �
_�o� � o ,
_ �W o Z� J_
. —
_�°~ � O W a°Q-
� �
-
= o%� Z 0 Q 40 =
— �
� �� N N �� �;
' ° v�
� � �y O o ��
;
.
�, �°°oo � oo° � .
/�/ �i,/,, ��OO000000�°� ` ♦
���i" �� o �� �
%,, P ����
�/111����11\� r -
.
� �
o �
,
� �
,� � . �o
�� �
0 0 '�
N V
NN �
�� �. .
���
NN '
��
��
c� c�