Loading...
HomeMy WebLinkAbout001 - ONE PDF IUH Rehab 100% Set 09-22-2015DAVID ARCHI T E C T R E G I S TERED AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:54 PM Title Sheet T0-1 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of NORTH HOSPITAL 11700 North Meridian Street | Carmel, Indiana 46032 Outpatient Rehab Renovation Drawing Index E000 Electrical Symbols and Legend E101 First Floor Power Plan P-1001st Floor Plumbing P-101Domestic Hot and Cold P-102Domestic Hold and Cold Iso P-103Sanitary Waste P-104Sanitary Vent P-105Sanitary Waste and Vent Iso P-106Sanitary Waste and Vent Details M1.14First Floor HVAC Plan - Area 4T0-1 Title Sheet A0-1 General Information A2-1 First Floor Plans A3-1 Enlarged Plans and Wall Sections A7-1 Door Schedule and Typical Details A9-1 Reflected Ceiling Plan A10-1Casework Elevations A10-2Casework Elevations A11-1Room Finish Plan REVISIONS DATE BY Architectural Mechanical Plumbing Electrical 1.CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE SITE TO BECOME FAMILIAR WITH AND VERIFY THE EXISTING CONDITIONS. THESE DEMOLITION DRAWINGS SHALL SERVE TO AID THE CONTRACTOR IN HIS EVALUATION OF THE EXTENT OF DEMOLITION; BUT SHALL NOT BE HELD TO BE ALL INCLUSIVE. 2.CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THE INSTALLATION OF NEW CONSTRUCTION AND AS NECESSARY TO FULFILL THE PURPOSE AND INTENT OF THE FINISHED WORK, WHETHER OR NOT IT IS SPECIFICALLY SHOWN OR NOTED IN THESE DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS CALLED TO BE REMOVED THROUGH OUT THE ENTIRE SET OF DOCUMENTS. 3.CONTRACTORS SHALL FIELD INSPECT ALL DEMOLITION WORK PRIOR TO REMOVAL, TO INSURE SUCH REMOVAL DOES NOT IMPAIR STRUCTURAL INTEGRITY OF THE EXISTING BUILDING. IF THE INSPECTION INDICATES THAT THE STRUCTURAL INTEGRITY MAY BE IMPAIRED, NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY. 4.REMOVE ALL DAMAGED OR EXISTING FINISH MATERIALS FROM REMAINING WALLS, PARTITIONS AND COLUMNS (GYPSUM BOARD,WALL FABRIC, PANELING, TILE, MASONRY, CONCRETE, ETC...). PATCH WALLS AND COLUMNS AS REQUIRED TO RECEIVE NEW FINISH MATERIALS. 5.CONTRACTORS SHALL BE RESPONSIBLE FOR PROVIDING, INSTALLING AND MAINTAINING DUST TIGHT TEMPORARY CONSTRUCTION BARRIERS TO ALL AREAS WITHIN THE CONSTRUCTION LIMIT LINES, DURING THE CONSTRUCTION PROCESS. LOCATIONS SHALL BE COORDINATED WITH THE OWNER AND ARCHITECT. 6.ALL CONSTRUCTION AREAS, REMOVAL TRAFFIC PATTERN AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN OF DEBRIS BY THE CONTRACTORS DAILY. 7.PROTECT FROM DEMOLITION AND RECONSTRUCTION DEBRIS, ALL "EXISTING TO REMAIN" FIXTURES AND EQUIPMENT REQUIRED TO REMAIN IN PLACE DURING CONSTRUCTION. 8.REFER TO REMAINING DRAWINGS FOR RECONSTRUCTION. ALL CONTRACTORS SHALL COORDINATE THE DEMOLITION AND RECONSTRUCTION WORK, TO BE ASSURED THAT THEIR WORK IS COMPLIMENTARY TO THE WORK OF ALL OTHER CONTRACTORS AND COMPLETE IN ALL RESPECTS. 9.UNLESS NOTED OTHERWISE ALL DEMOLITION MATERIAL BECOMES THE PROPERTY OF THE CONTRACTORS AND IS TO BE REMOVED FROM THE PROPERTY, IN A LEGAL MANNER. THE OWNER RESERVES THE RIGHT AND SHALL BE GIVEN THE OPPORTUNITY TO CLAIM ITEMS WHETHER OR NOT THOSE ITEMS WERE SPECIFICALLY NOTED FOR REMOVAL, RELOCATION, OR AS RETURNED TO OWNER AND SAME SHALL BE RETURNED TO OWNER. 10.THE CONTRACTOR RESPONSIBLE FOR GENERAL DEMOLITION WORK SHALL COORDINATE ANY AND ALL ASBESTOS REMOVAL WITH THE OWNER. ALL ASBESTOS REMOVAL WILL BE PREFORMED BY A LICENSED ASBESTOS REMOVAL CONTRACTOR. THIS TYPICALLY INCLUDES FLOOR TILE, TILE MASTIC AND PIPE INSULATION. 11.ITEMS SHOWN IN LIGHTER PEN WEIGHTS ARE EXISTING TO REMAIN. 12.GENERAL CONTRACTOR RESPONSIBLE FOR PATCHING ALL REMOVED ELECTRICAL OUTLETS. ELECTRICAL CONTRACTOR TO PROVIDE GENERAL CONTRACTOR WITH QUANTITIES. 13.REMOVE EXISTING FINISHES AS REQUIRED TO INSTALL NEW FINISHES. PREPARE SURFACES TO RECEIVE NEW FINISH AS PER FINISH MANUFACTURER'S PRINTED INSTRUCTIONS, SEE FINISH SCHEDULE FOR NEW FINISHES. 14.REMOVE EXISTING CEILINGS AND CEILING SUPPORT SYSTEM WHERE NEW CEILINGS ARE INDICATED, UNLESS OTHERWISE NOTED. THESE NOTES SHALL APPLY TO ALL DEMOLITION DRAWINGS AND TO ALL CONTRACTORS AND/OR SUBCONTRACTORS THAT WORK ON THIS PROJECT. INDICATES EXISTING WALL TO BE REMOVED IN ITS ENTIRETY. INDICATES EXISTING DOOR, FRAME AND ASSOCIATED HARDWARE TO BE REMOVED IN ITS ENTIRETY. SEE DOOR SCHEDULE FOR ITEMS TO BE SALVAGED AND REUSED IN OTHER AREAS. THESE NOTES APPLY TO ALL FLOOR PLANS, AND TO ALL CONTRACTORS AND/OR SUBCONTRACTORS THAT WORK ON THIS PROJECT. 1.OWNER WILL REMOVE ALL FURNISHINGS, LOOSE EQUIPMENT, SUPPLIES, ETC.... PRIOR TO CONSTRUCTION COMMENCING. 2.ALL EQUIPMENT AND MATERIALS LABELED AS "SALVAGE" OR "RELOCATE AS DIRECTED BY OWNER" SHALL BE REMOVED, PROPERLY PROTECTED AND TRANSPORTED TO A LOCATION ON THE PREMISES AS DIRECTED BY THE OWNER. 3.ALL GENERAL CONTRACTORS AND THEIR SUBCONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE CONSTRUCTION SITE TO BECOME FAMILIAR WITH ALL EXISTING CONDITIONS WHICH AFFECT THAT SPECIFIC PORTION OF THEIR WORK. ANY CONFLICTS OR APPARENT DEFICIENCIES MUST BE SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BIDDING. 4.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMING IN WRITING THE OWNER ON A WEEKLY BASIS OF THE CONSTRUCTION SCHEDULE FOR THE APPROACHING TWO WEEKS CONSTRUCTION ACTIVITY. ANY STORAGE OF MATERIALS, ACCESS OR EGRESS PROBLEMS, TRAFFIC FLOW OR NORMAL OWNER OPERATIONS WHICH ARE TO BE AFFECTED MUST BE PROTECTED AND/OR AGREED UPON BY THE OWNER. ALL COSTS SHALL BE INCURRED BY THE GENERAL CONTRACTOR. 5.THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY WOOD BLOCKING FOR ALL TRADES. THIS BLOCKING SHALL BE FIRE RETARDANT. 6.ANY PLASTER WORK REQUIRING NEW FINISH SHALL BE SMOOTH, SOUND AND IN A FLUSH PLANE BEFORE FINISH APPLICATION. CONTRACTOR SHALL REPAIR THE SURFACE FOR THE NEW FINISH AS SCHEDULED. 7.ALL FIRE RATED WALLS AND FLOOR PENETRATIONS MUST COMPLY WITH ASTME-814. 8.ITEMS SHOWN IN LIGHTER PEN WEIGHT ARE EXISTING TO REMAIN. 9.REMOVE ALL DAMAGED GYPSUM BOARD, MASONRY, CONCRETE, PLASTER, ETC... FROM EXISTING SURFACES AND REPAIR TO MATCH ADJACENT CONSTRUCTION PRIOR TO REFINISHING. ALL SURFACES SHALL BE SMOOTH AND IN A FLUSH PLANE. 10.ALL CONSTRUCTION AREAS, REMOVAL TRAFFIC PATTERN AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN OF DEBRIS BY THE CONTRACTORS DAILY. 11.PROTECT FROM DEMOLITION AND RECONSTRUCTION DEBRIS, ALL "EXISTING TO REMAIN" FIXTURES AND EQUIPMENT REQUIRED TO REMAIN IN PLACE DURING CONSTRUCTION. 12.REFER TO REMAINING DRAWINGS FOR RECONSTRUCTION. ALL CONTRACTORS SHALL COORDINATE THE DEMOLITION AND RECONSTRUCTION WORK, TO BE ASSURED THAT WORK IN EITHER OF THESE AREAS IS COMPLEMENTARY TO THE OTHER AND COMPLETE IN ALL RESPECTS. ANY CONFLICTS OR APPARENT DEFICIENCIES MUST BE SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BIDDING. 13.ALL WALL HUNG CASEWORK REQUIRES CONTINUOUS HORIZONTAL WOOD BLOCKING BETWEEN STUDS AT TOP AND BOTTOM OF CASEWORK. BRACE WALL TO DECK AS REQUIRED. 14.ALL DIMENSIONS ARE FROM FACE OF BASE MATERIAL (STUD/CMU) TO FACE OF BASE MATERIAL (STUD/CMU) UNLESS NOTED OTHERWISE. 15.PORTIONS OF THE BUILDING SHALL BE OCCUPIED DURING CONSTRUCTION. THE GENERAL CONTRACTOR SHALL FOLLOW THE FOLLOWING LIFE SAFETY ISSUES. FAILURE TO LIST ALL LIFE SAFETY ISSUES DOES NOT RELIEVE THE CONTRACTORS FROM COMPLYING WITH FEDERAL, STATE AND LOCAL CODES, THE CONTRACTUAL AGREEMENT BETWEEN THE CONTRACTOR AND OWNER, AND OTHER GOVERNING BODIES WHICH HAVE JURISDICTION ON THIS PROJECT. THE FOLLOWING ARE INTERIM LIFE SAFETY CODE ISSUES WHICH ARE SPECIFIC TO THIS PROJECT AND MUST BE ADDRESSED: a.INSURE ALL EXITS PROVIDE FREE AND UNOBSTRUCTED EGRESS. STAFF AND PERSONNEL SHALL RECEIVE TRAINING AND WRITTEN NOTIFICATION IF ALTERNATIVE EXITS MUST BE DESIGNATED. b.INSURE FREE AND UNOBSTRUCTED ACCESS TO EMERGENCY DEPARTMENTS OR SERVICES FOR EMERGENCY FORCES. COORDINATE WITH OWNER AND ARCHITECT. c.INSURE FIRE ALARM, DETECTION AND SUPPRESSION SYSTEMS ARE NOT IMPAIRED. A TEMPORARY, BUT EQUIVALENT, SYSTEM SHALL BE PROVIDED, INSTALLED AND TESTED PRIOR TO ANY EXISTING FIRE SYSTEM BEING IMPAIRED. d.INSURE TEMPORARY CONSTRUCTION PARTITIONS ARE SMOKE TIGHT AND BUILT OF NON COMBUSTIBLE MATERIALS. THESE PARTITIONS SHALL BE COORDINATED WITH THE OWNER AND ARCHITECT. e.SMOKING SHALL BE PROHIBITED EXCEPT IN DESIGNATED AREAS OF THE BUILDING. f.DEVELOP AND ENFORCE STORAGE, HOUSEKEEPING AND DEBRIS REMOVAL PROCEDURES THAT REDUCE THE FLAMMABLE AND COMBUSTIBLE FIRE LOAD TO THE LOWEST LEVEL NECESSARY FOR DAILY OPERATIONS. g.IOSHA REQUIRES MATERIAL SAFETY DATA SHEETS (MSDS) FOR ALL MATERIALS BEING USED OR STORED ON THIS PROJECT BE MADE AVAILABLE TO ALL WORKERS ON THIS JOBSITE. COPIES MUST BE PROVIDED TO THE OWNER'S DIRECTOR OF SECURITY, IMMEDIATELY, AS WORK BEGINS. h.SECURE ALL TOOLS AND CONSTRUCTION MATERIALS DURING BREAKS AND NON-CONSTRUCTION HOURS. 1.ALIGN ALL CEILING AND BULKHEAD REVEALS, CONTROL OR SEISMIC JOINTS WITH THE ADJACENT REVEAL, CONTROL OR SEISMIC JOINTS IN WALLS INDICATED ON ELEVATIONS. 2.ALL CEILING AND BULKHEAD HEIGHTS INDICATED ARE TO FINISHED FACE OF GYPSUM BOARD OR TO THE BOTTOM FACE OF ACOUSTICAL CEILING TILE PAD, UNLESS NOTED OTHERWISE. 3.CEILING CONTRACTOR TO PROVIDE ALL CEILING GRID TO SUPPORT HVAC SUPPLY DIFFUSERS AND RETURN GRILLS. 4.DEVICES OTHER THAN LIGHTING AND DIFFUSERS ARE SHOW IN APPROXIMATE LOCATIONS, FINAL LOCATION TO BE COORDINATED WITH ALL TRADES AND ARCHITECT. 5.AT LOCATIONS WHERE GYPSUM BOARD CEILINGS ARE INDICATED, THE CONTRACTOR HAS THE OPTION TO USE LIGHT GAGE METAL FRAMING OR SUSPENDED GYPSUM BOARD GRID UNLESS OTHERWISE DETAILED. THE CONTRACTOR WILL COORDINATE ANY MODIFICATIONS WITH THE OTHER TRADES ON THE PROJECT. THE CEILING CONTRACTOR'S FINAL MEANS AND METHODS WILL NOT CONFLICT WITH THE WORK OF OTHERS OR THE INTENT OF THESE DOCUMENTS. 6.WHERE EXISTING SUSPENDED ACOUSTICAL CEILINGS ARE SCHEDULED TO REMAIN, CUT AND PREP THE CEILING GRID IN PREPARATION FOR REPAIRING. SALVAGE ENOUGH CEILING PADS FOR RECONSTRUCTION. STORE AND PROTECT ALL MATERIALS. USE NEW MATCHING MATERIALS FOR RECONSTRUCTION AS REQUIRED. 7.SEE THE ROOM FINISH SCHEDULE FOR ADDITIONAL COMMENTS REGARDING MATERIALS AND FINISHES. 8.THE DESIGNATION 'CJ' INDICATES GYPSUM BOARD CONTROL JOINTS. WHERE INDICATED PROVIDE USG #093 ZINC CONTROL TYPICAL. INSTALL JOINT THROUGH THE FULL EXTENTS OF ANY GYPSUM CEILING OR BULKHEAD. WHERE THE GYPSUM CEILING COMPONENT MEETS A GYPSUM WALL, EXTEND THE CONTROL JOINT DOWN TO THE FLOOR TYPICAL. 9.THE GENERAL CONTRACTOR WILL PROVIDE AND INSTALL ALL SUPPLEMENTAL AND/ OR MISCELLANEOUS STEEL FRAMING AS REQUIRED BY THEMSELVES OR BY THEIR SUBCONTRACTORS FOR THE INSTALLATION OF THE EQUIPMENT SCHEDULED AND SPECIFIED. NOT ALL OF THE REQUIRED SUPPORT STEEL MAY BE DETAILED OR CALLED OUT FOR IN THESE DOCUMENTS. COORDINATE ALL REQUIREMENTS WITH THE SPECIFICATIONS, EQUIPMENT SUPPLIERS AND SUBCONTRACTORS. THERE WILL BE NO CHANGE ORDERS TO THE PROJECT FOR SUPPLEMENTAL STEEL WHERE OMISSIONS MAY OCCUR IN THE BIDDING DOCUMENTS. THESE NOTES APPLY TO ALL CONSTRUCTION DRAWINGS AND TO ALL CONTRACTORS AND/OR SUBCONTRACTORS THAT WORK WITHIN THIS BUILDING. Architectural: Nick Slater Kyle Hardie MSKTD & Associates 317.917.1190 Interiors: Sarah Savage MSKTD & Associates 317.917.1190 ROOM NAME 101 1t 1 A 101A A101 1 SIM DETAIL NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER X X SHEET NUMBER DETAIL NUMBER NEW DOOR AND FRAME SPECIFIC CONSTRUCTION NOTES ROOM NAME AND NUMBER ELEVATION SYMBOL PLAN DETAIL NEW COLUMN LINE EXISTING COLUMN LINE SECTION PARTITION TYPE WINDOW ELEVATION SYMBOL TOILET ACCESSORY 1 SPECIFIC DEMOLITION NOTES 1i3.5Ax / Xx-x 1 A101 EXTEND TO 6" A.F.C. 1.5A 1.5B 3 5/8" METAL STUD @ 16" O.C. 5/8" GYPSUM BOARD EACH SIDE SOUND ATTENUATION BLANKET INSULATION 3 5/8" METAL STUD @ 16" O.C. 5/8" GYPSUM BOARD EXTEND TO 6" A.F.C. 1'-5" MIN. 1'-7" TO SEAT HDCP. MAX. 1'-5" MIN. SPACE MUST REMAIN FREE AND CLEAR OF OBSTRUCTION 2'-10" HDCP MAX. 2'-3" HDCP MIN. 8" 6" 9"2'-5" MIN. WALL MOUNT WATER CLOSET 17" - 19" MIN. CLEAR 2'-3" HDCP MIN. 9" MIN. 8" MAX 6" MAX 3' - 0" HDCP DRINKING FOUNTAIN 59" MIN. (AT FLOOR-MOUNTED TOILET) 4' - 10" 1' - 0" 56" MIN. (AT WALL-HUNG TOILET) TOILET PARTITION (WHERE OCCURS) 6" 12" MIN. 24" MIN. 16" - 18"33" - 3 6" 17" - 19" 17" MAX. ACC ESSIBL E HEIG HT 24" STD. 3' - 6" 1' - 0" 2' - 0" 15" MIN. WATER CLOSET SIDE WALL 1 1/2" DIA. GRAB BAR WITH 1 1/2" GAP FROM WALL WATER CLOSET BACK WALL URINAL ACCESSIBLE SEAT HT.TOILET PAPER MOUNTING AREA URINAL SCREEN (WHERE OCCURS) LAVATORY OR VANITY SINK 60" MIN. MIN. 9" 6" TOE SPACE 6" TOE SPACE SEE PLANS FOR PROJECT-SPECIFIC DIMENSIONS SEE PLAN NOTES: 1.REFERENCE THE CURRENT APPLICABLE STATE AND FEDERAL ACCESSIBILITY STANDARDS FOR ACCESSIBLE DESIGN. 2.SEE FLOOR PLANS AND OTHER DETAILS FOR APPLICABLE PROJECT SPECIFIC REQUIREMENTS AND DIMENSIONS. 3.AMBULATORY ACCESSIBLE COMPARTMENTS AND FIXTURES, WATER CLOSETS, AND TOILET COMPARTMENTS FOR CHILDREN'S USE ARE NOT SHOWN. SEE APPLICABLE CODES FOR REQUIREMENTS. 39" - 41" 54" MIN. 42" MIN. 12" MAX. MIN. 1 1/2" 15" MIN. 7" - 9"MIN. 9" TOILET PARTITION (WHERE OCCURS) VERTICAL GRAB BAR 36" MIN. STANDARD ROLL-IN-TYPE SHOWER WITH SEAT 60" MIN. WIDTH 30" MIN. DEPTH STANDARD ROLL-IN-TYPE SHOWER WITH SEAT MAX. 6" MAX. 6" 33" - 36"MIN. 1 1/2" 38" MIN. 48 " MAX. 27" MAX. 17" - 19 " SEAT HEIGHT CONTROL LOCATION FOLDING-TYPE ACCESSIBLE SHOWER SEAT 33" - 36" BACK WALL ALL METAL STUD WALLS OVER 10'-0" TALL SHALL BE LATERALLY BRACED ABOVE 10'-0" WITH 1 1/2" COLD ROLLED CHANNELS AT 48" O.C. VERTICALLY. ATTACHMENT SHALL BE AS DESCRIBED AND ILLUSTRATED IN THE "UNIMAST INCORPORATED", STEEL FRAMING SYSTEMS, TECHNICAL INFORMATION MANUAL. 0=EXISTING 1=METAL STUDS 2=MASONRY 3=WOOD 4=CONCRETE 5=MISC 0=EXISTING O= EXISTING CONSTRUCTION MATERIALS AND SIZE OF WALL ARE TO BE VERIFIED BY THE GENERAL CONTRACTOR 1=METAL STUDS 1=7/8" 2=1 5/8" 3=2" 4=2 1/2" 5=3 5/8" 6=4" 7=6" 8=EXTERIOR COMPOSITE WALLS 9= INTERIOR COMPOSITE WALLS 2=MASONRY 1=1 5/8" 2=2 5/8" 3=3 5/8" 4=5 5/8" 5=7 5/8" 6=9 5/8" 7=11 5/8" 8=EXTERIOR COMPOSITE WALLS 9=INTERIOR COMPOSITE WALLS 3=WOOD 1=1 1/2" (2") 2=2 1/2" (3") 3=3 1/2" (4") 4=4 1/2" (5") 5=5 1/2" (6") 6=7 1/4" (8") 7=9 1/4" (10") 8=EXTERIOR COMPOSITE WALLS 9=INTERIOR COMPOSITE WALLS 4=CONCRETE 1=4" 2=6" 3=8" 4=10" 5=12" 6=18" 7=24" 8=EXTERIOR COMPOSITE WALLS 9=INTERIOR COMPOSITE WALLS 5=MISC 1=PRE-ENGINEERED BUILDING DESCRIBES THE BASE WALL MATERIAL INDICATES THE DEPTH OF THE BASE WALL MATERIAL 1 . 5 A DESCRIBES THE MATERIALS BEING USED TO COVER THE BASE WALL MATERIALS. SEE SHEET A0.1 48" MAX. 2' - 10" HDCP. 15" MIN. SANITARY NAPKIN DISPOSAL TO OPERABLE MECH ANISM 4' - 0" MAX. SOAP DISPENSER 48" M AX H DCP. 54" M AX. TOILET SEAT COVER DISPENSER SANITARY NAPKIN / TAMPON DISPENSER TO OPERABLE MECHANISM 48" HDCP. FORWARD REACH TO OPE RABLE MECHANISM 54" MAX. SIDE R EACH ROBE HOOK SHOWER CURTAIN ROD HAND DRYER 48" MAX. HDCP. 6' - 0" 6' - 8" MAX. HDCP. 4' - 0" CENTERLINE OF UPPER MOST CONTROL CL 6" MIN. STAINLESS STEEL HINGED ACCESS PANEL 1'-4" X1'-4" STAINLESS STEEL HINGED ACCESS PANEL 1'-4" X1'-4" 3' - 6" MAX. ACCESS PANEL BELOW LAVATORY ACCESS PANEL ABOVE TOILET 48" MAX. TO OPERABLE MECHANISM 48" MAX. MIRROR PAPER TOWEL DISPENSER ABOVE LAVATORIE S, SINKS, OR COUNTE RS 40" MAX.* SEE PLAN ROOM SIGNAGE 5' - 0" 4" SURFACE MOUNTED FULL-LENGTH MIRROR SEE PLAN SEE PLAN 1' - 4"OTHER CONDITIONS ROBE HOOK 48" MAX. SHELVES 40" MIN. - 48" MAX. *DIMENSION IS TO BOTTOM OF REFLECTIVE SURFACE TOILET PAPER DISPENSER 15" MIN. 7" - 9" PROPOSED USE Healthcare Clinic CLASSIFICATION B-Business IBC sec. 308.3 CONSTRUCTION TYPE Type I-A IBC Table 601 AUTOMATIC SPRINKLERS Fully Sprinkled, Class I FLOOR AREA Medical Office Suite 5,530 sq. ft. HEIGHT (7) Seven Stories 106' - 8" FIRE RESISTANT REQUIREMENTS Structural Frame 3-Hours IBC Table 601 Exterior Bearing Walls 3-Hours Floor 2-Hour Roof 1-1/2 Hour Shafts 1-Hour (Less than 3-Stories)IBC 707.4 2-Hours (4 Story) Stairs 1-Hour (Less than 3-Stories)IBC 1005.3.2 2-Hours (4 Story) APPLICABLE CODES NFPA 101 Life Safety Code: 2000 Edition. Chapter 18 New Healthcare Occupancies Guidelines for Design and Construction of Hospital and Healthcare Facilities: 2001 Edition. Indiana Fire Prevention and Building Safety Code IAC 675 General Administrative Rules (GAR) Building Code:2014 Indiana Building Code Plumbing Code:2012 Indiana Plumbing Code (IPC) Electrical Code:2009 Indiana Electrical Code (IEC) Mechanical Code:2014 Indiana Mechanical Code (IEC) with Indiana Amendments The Indiana Energy Conservation Code (IECC), 2010 Edition (consisting of ASHRAE 90.1, 2007 Edition with Indiana Amendments) Fire Code:2014 Indiana Fire Code (IFC) Handicapped Accessiblility Code: 2014 Indiana Building Code Chapter 11 (consisting of 675 IAC 13-2.5-12 Chapter 11) 1 HOUR FIRE (Hazardous Rooms) 2 HOUR FIRE (Occupancy Separation, Smoke Proof Enclosures, Exit Passageways, and Vertical Openings SMOKE BARRIER WALL (1 Hour Rated Walls, 20 Min. Rated Doors) TRAVEL DISTANCE SMOKE TIGHT EXIT ACCESS CORRIDOR (Non-Rated Corridors; Hazardous Areas) FEC -Fire Extinguisher Cabinet DAVID ARCHI T E C T R E G I S TERED AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:34 PM General Information A0-1 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of General Demolition Notes General Reconstruction Notes General Ceiling Plan Notes Contacts Graphic Symbols Partition Types Plumbing Fixture Mounting Heights Partition Standards Toilet Accessory Mounting Heights Code Summary 1/16" = 1'-0" First Floor Life Safety Plan Rated Wall Legend REVISIONS DATE BY 1514.9 16 16.1 16.314131211.411.311109.9 A B C D ADULT GYM K197 EXAM 5 K195 EXAM 4 K194 EXAM 3 K193 EXAM 2 K192 TEP / EXAM 1 K191 Pt. TOILET K190 SPEECH K188 STORAGE K187 FLEX ROOM 1 K186 STORAGE K179 Pt. TOILET K178E LINEN CABINETS K185 PEDS GYM K178 PEDS EXAM 1 K178DBREAK ROOM K181 EXAM 6 K178C 12 SEATS ADULT CHARTING K199 STORAGE K198 1 4 5 A3-1 2 A3-1 4 A3-1 3 5/ A10-1 8/ A10-1 K191K192K193K194K195K196 K198 K190 K189 K199 K188 K187 K186 K178EK179K183 K176 K177 K178D K178C 11 1 1 1 1 1 6/ A10-1 7/ A10-1 CORRIDOR K176A CONSULT K183 OFFICE K189 WORKROOM K177ARECEPTION K177 STORAGE K178B STORAGE K178A A3-1 1 K172B AUDIO VIS K182 PUBLIC TOILET K172A WORK K170 SECURITY K170A OFFICE K170C OFFICEK170B SECURITY K172 CLASS K173 CLASS K1C09 CORRIDOR K1C10 ELEV LOBBY K174 CLASS K175 CLASS K1C06 ELEV LOBBY ELEV-2 ELEVATOR ELEV-3 ELEVATOR K180 PUBLIC TOILET 3 10' - 0 3/4"6' - 11 3/8" 3' - 0" 2' - 5" 11' - 1 3/8"10' - 7 1/8" 3 3 6' - 4 1/4" 6' - 7" 8' - 2" 3 4 10' - 5" 16' - 1" CORRIDOR K1C13 1 6 6 7 8 12/ A7-1 CORRIDOR K1C03 PASSAGE K178F 2 11' - 5 5/8"1' - 11 3/8"18' - 5 5/8"11' - 5 7/8"5' - 0 1/4" 2' - 1 1/4" 1 3 3 1' - 7 1/8" 1 4' - 5 7/8" 1' - 2 1/2" 1 1 0 .0 0 ° 4' - 3 3/4"11' - 8"4" 11' - 6 1/2 " 10 K201 EXAM 6 K196WAITING K200 OFFICE K201 1 WAITING K176 9 1.ALL FURNITURE PROVIDED BY OWNER. 2.SEE SHEET A10-1 THRU A10-2 FOR CASEWORK ELEVATIONS. 3.SEE A3-1 FOR ENLARGED PLANS. 4.DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED. 5.ALL HINGED SIDE DOOR JAMBS AT STUD WALLS ARE 4" FROM FACE OF STUD UNLESS OTHERWISE NOTED. 6.ALL PARTITION TYPES ARE TO BE 1.5A UNLESS OTHERWISE NOTED. 7.ROBE/COAT HOOK TYPICAL ON ALL EXAM ROOM AND TOILET ROOM DOORS. 1514.9 16 16.1 16.314131211.411.311109.9 A B C D K177 GYM K177F STORAGE K177D STAFF TOILET K1C11 CORRIDOR K177E WORK K178D TREATMENT/EXAM K178C CAST K178 GYM K178B STORAGE K178A STORAGE K177C LOUNGE K176 WAITING K177A OFFICE K174A RECEPT K177B STORAGE K177H TREATMENT/EXAM K1C13 CORRIDOR K177G TREATMENT/EXAM K177J TREATMENT/EXAM K177K TREATMENT/EXAM K177L TREATMENT/EXAM K177M PATIENT TOILET K195 GYM K194 OFFICE K193 WORK K190 WAITING K1C14 CORRIDOR K195A OFFICE K192 OFFICE K191 OFFICE K191A WORK K172B AUDIO VIS K182 PUBLIC TOILET K172A WORK K170 SECURITY K170A OFFICE K170C OFFICEK170B SECURITY K172 CLASS K173 CLASS K1C09 CORRIDOR K1C10 ELEV LOBBY K174 CLASS K175 CLASS K1C06 ELEV LOBBY ELEV-2 ELEVATOR ELEV-3 ELEVATOR K180 PUBLIC TOILET K1C03 CORRIDOR 3 4 111 1 1 1 1 22 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 33 3 3 4 4 4 3 4 4 4 4 4 4 4 4 5 5 5 5 5 2 1 6 6 7 8 4 6 6 6 6 6 7 6 6 6 9 6 10 9 6 9 6 6 11 96 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 121212 12 12 12 14 2 13 1 6 6 12 12 2 4 1.REMOVE EXISTING ACCESSORIES, i.e. TACKBOARDS, TOILET ACCESSORIES, ETC. 2.REMOVE EXISTING FLOOR THROUGHOUT SPACE AND PREP SUBSURFACE FOR NEW FLOORING. EXISTING TOILET ROOMS ARE CERAMIC TILE. DAVID ARCHI T E C T R E G I S TERE D AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:38 PM First Floor Plans A2-1 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of 1/8" = 1'-0" First Floor Plan Outpatient Rehab Specific Plan Notes 1 ALIGN NEW WALL FINISH WITH ADJACENT EXISTING CONSTRUCTION. 2 EXISTING DESK RELOCATED. 3 INFILL WALL OPENING WITH SIMILAR CONSTRUCTION. ENSURE THAT NEW SURFACES ARE FLUSH WITH ADJACENT CONSTRUCTION. 4 SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER BY OWNER. 5 (DASHED, BOLD LINE) EXTENDED EXISTING WALL CONSTRUCTION TO DECK AS REQUIRED FOR 2-HOUR RATED CONSTRUCTION. INSTALL 2-LAYERS OF 5/8" TYPE "X" GYPSUM BOARD ON BOTH SIDES. 6 5'-0" x 6'-0" THERAPY MAT BY OWNER. 7 WALL OPENING WITH 7'-2" FINISHED HEAD HEIGHT. 8 REFRIGERATOR BY OWNER. 9 FRAME WALL TO MATCH EXISTING PROFILE AND ANGLE AT EXISTING CASEWORK / RECEPTION DESK TO BE RELOCATED. 10 RELOCATED FULL GLASS ENTRY SYSTEM. MODIFY SILL AND HEAD CONDITIONS IN FIELD SO THAT NOT EXISTING GLASS PANELS SHALL BE CUT. PROVIDE OVERHEAD STEEL FRAMING AS NECESSARY. General Plan Notes 1/8" = 1'-0" First Floor Demolition Plan Outpatient Rehab Specific Demolition Notes 1 REMOVE PORTION OF EXISTING WALL FRAMING FOR NEW DOOR OPENING. COORDINATE OPENING SIZE WITH ARCHITECTURAL DRAWINGS. 2 REMOVE EXISTING DOOR, FRAME, AND HARDWARE IN ITS ENTIRETY. 3 REMOVE EXISTING PLUMBING FIXTURES IN ITS ENTIRETY. 4 REMOVE EXISTING CASEWORK IN ITS ENTIRETY. 5 EXISTING CEILING AND CASEWORK TO REMAIN. 6 REMOVE EXISTING WALL IN ITS ENTIRETY. 7 REMOVE EXISTING SHELVING IN ITS ENTIRETY. 8 REMOVE EXISTING WATER HEATER. REFER TO MECHANICAL DRAWINGS. 9 REMOVE EXISTING INTERIOR WINDOW IN ITS ENTIRETY. 10 REMOVE EXISTING LOCKERS IN THEIR ENTIRETY. 11 REMOVE EXISTING FIRE EXISTINGUISHER AND CABINET AND RETURN TO OWNER. 12 REMOVE EXISTING CEILING IN ITS ENTIRETY. 13 REMOVE FULL HEIGHT GLASS WALL AND VERIFY ENTRY DOOR. SALVAGE, PROTECT AND REINSTALL AT NEW LOCATION. 14 REMOVE EXISTING DESK. SALVAGE, PROTECT AND REINSTALL AT NEW LOCATION. SEE FLOOR PLAN FOR NEW LOCATION. General Demolition Notes REVISIONS DATE BY Tectonic Copyright 2007 1.ACCESSORY PROVIDED AND INSTALLED BY CONTRACTOR. 2.ACCESSORY PROVIDED AND INSTALLED BY OWNER. BLOCKING PROVIDED BY CONTRACTOR, VERIFY LOCATION. 3.ACCESSORY PROVIDED BY OWNER. INSTALLED BY CONTRACTOR. 4.SEE FINISH SCHEDULE AND SPECIFICATIONS. 3/ A10-2 4/ A10-2 5/ A10-2 8/ A10-2 9/ A10-2 10/ A10-2 7/ A10-2 6/ A10-2 2/ A10-2 1/ A10-2 PEDS EXAM 1 K178D EXAM 6 K178C BREAK ROOM K181 WORKROOM K177A RECEPTION K177 CORRIDOR K176A PEDS GYM K178 E F K178C K178D K177 5' - 0 3/4"8' - 10 7/8"7' - 0 7/8" 7' - 5 7 /8 " 6' - 3 1/8" 6' - 10 1 /4" 3' - 10 1/4" 9' - 10 3/4" 3' - 4" 1' - 3 1/2" 4 5/8 " 4' - 0" 4' - 1 5/8" 1' - 3" 8' - 0"2' - 11" 4' - 6"7' - 1 1/2" WALL OPENING 3' - 6" COPY/ PRINT -/ --- 4' - 4 7/8" Pt. TOILET K178E A B C D EFG H J EF 1/ A10-1 2/ A10-1 K178E 1.5B 1.5B FLEX ROOM 1 K186 STORAGE K187 SPEECH K188 STORAGE K179 PEDS GYM K178 EF 4/ A10-1 SIM 4/ A10-1 SIM K188 K187 K186 K179 2' - 0" 2' - 4 7/8" 10' - 4 7/8" 10' - 6 3/4"12' - 4 7/8"2' - 1 1/4" 6' - 7" 8 ' - 2 " 7' - 6 3/4" 6' - 11 5/8" 1' - 6" 11 3/8" 1' - 6" EF EXISTING TERRAZZO BASE EXISTING 1/2" DRYWALL REVEAL 1/2" DRYWALL REVEAL (SIMILAR TO FRY-REGLET #DRM-50-625) SOLID SURFACE COUNTERTOP (SS-2 - "BLACK") 5/8" GYPSUM BOARD (FLUSH w/ EXISTING ADJACENT) 1/2" DRYWALL REVEAL (SIMILAR TO FRY-REGLET #DRM-50-625) PLASTIC LAMINATE (PL-1) ACCENT PANELS w/ 1/2" REVEALS PLASTIC LAMINATE (PL-1) ACCESS HOUSING ENCLOSURE. ENCLOSURE TO RUN FROM SIDE WALL TO SIDE WALL w/ ACCESSIBLE CLIPS. CONTRACTOR TO COORDINATE DESIGN w/ OVERHEAD COILING DOOR UNIT. GYPSUM BOARD SIDE JAMBS OVERHEAD COILING DOOR, FACE OF WALL MOUNT (MANUAL, CHAIN OPERATED) A7-1 9 A7-1 9 SIM. 3" 6" 1' - 9" 1' - 0" 5 1/2"2 1/2" 8 1/2" 4 " 9 1/2 " 3' - 6" 3' - 6" 1/2" +/- 1' - 1 1/2"4 3/8"5/8" OFFSET 1' - 9" 2' - 6" 2' - 0" E F H 4/ A10-1 3/ A10-1 K192 4/ A10-1 SIM H EXAM 2 K192 TEP / EXAM 1 K191 LINEN CABINETS K185 8' - 3 1/4" 2' - 1 3/4" K191 10' - 0 7/8"11' - 9 1/4" E F Pt. TOILET K190 A B C D EFG H J K190 1.5B 1.5B 1' - 6"1' - 6" 6' - 11 3/8" 9' - 1 " 1' - 3 3/8" EXISTING TERRAZZO BASE EXISTING 1/2" DRYWALL REVEAL 8 1/2 " 4 " 9 1/2 " 4' - 6" 2' - 6" 3" 6 " 9" 1' - 0" 1/2" DRYWALL REVEAL (SIMILAR TO FRY-REGLET #DRM-50-625) SOLID SURFACE COUNTERTOP (SS-2 - "BLACK") 6" 5/8" GYPSUM BOARD (FLUSH w/ EXISTING ADJACENT) 1/2" DRYWALL REVEAL (SIMILAR TO FRY-REGLET #DRM-50-625) +/- 1' - 1 1/2"4 3/8"5/8" SETBACK 1/2" PLASTIC LAMINATE (PL-1) ACCENT PANELS w/ 1/2" REVEALS PLASTIC LAMINATE (PL-1) ACCESS HOUSING ENCLOSURE. ENCLOSURE TO RUN FROM SIDE WALL TO SIDE WALL w/ ACCESSIBLE CLIPS. CONTRACTOR TO COORDINATE DESIGN w/ OVERHEAD COILING DOOR UNIT.1' - 9" GYPSUM BOARD SIDE JAMBS 2' - 6" 1 1/2" 2' - 0" OVERHEAD COILING DOOR, FACE OF WALL MOUNT (MANUAL, CHAIN OPERATED) A7-1 9 A7-1 9 SIM. DAVID ARCHI T E C T R E G I S TERED AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:41 PM Enlarged Plans and Wall Sections A3-1 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of Outpatient Rehab Toilet Accessories Schedule NOTE: MANUFACTURER'S NUMBERS REFER TO "BOBRICK CO." UNLESS NOTED OTHERWISE, AND ARE USED FOR QUALITY CONTROL ONLY. THEY ARE NOT INTENDED TO LIMIT BIDDING TO ONE MANUFACTURER. ITEM ACCESSORY DESCRIPTION MANUFACTURER'S NUMBERS REMARKS A SINGLE GRAB BAR - 42"B-6806x42 1 B SINGLE GRAB BAR - 36"B-6806x36 1 C SINGLE GRAB BAR - 18" (VERTICAL)B-6806x18 1 D SURFACE MOUNTED 2 ROLL TOILET PAPER DISPENSER --2 E SURFACE MOUNTED PAPER TOWEL DISPENSER --3 F SURFACE MOUNTED SOAP DISPENSER --2 G 24" x 36" MIRROR B-165-2436 1 H ROBE/COAT HOOK B-6717 1 J SANITARY NAPKIN DISPOSAL B-254 1 Toilet Accessory Remarks 1/4" = 1'-0" Enlarged Plan1 1/4" = 1'-0" Enlarged Plan2 3/4" = 1'-0" Wall Section5 1/4" = 1'-0" Enlarged Plan3 1/4" = 1'-0" Enlarged Plan4 3/4" = 1'-0" Wall Section6 REVISIONS DATE BY HARDWARE SET #1 (STORAGE) 3 HINGES - 5 KNUCKLE 1 LOCKSET - STORAGE FUNCTION 1 CYLINDER CORE 1 WALL BUMPER 3 DOOR SILENCER HARDWARE SET #2 (EXAM/TREATMENT ROOMS) 3 SWING CLEAR HINGES 1 PASSAGE SET 1 WALL BUMPER 3 DOOR SILENCER HARDWARE SET #3 (STAFF/PATIENT TOILET) 3 HINGES - 5 KNUCKLE 1 PRIVACY SET 1 WALL BUMPER 3 DOOR SILENCER HARDWARE SET #4 (OFFICES) 3 HINGES 1 LOCKSET - OFFICE FUNCTION 1 CYLINDER CORE 1 WALL BUMPER 3 DOOR SILENCER HARDWARE SET #5 (RATED DOOR - 90 MIN.) 3 HINGES 1 PASSAGE LOCKSET 1 CLOSER 1 WALL BUMPER 3 DOOR SILENCER BACKER ROD AND SEALANT (BOTH SIDES) 4 1/2" ALUMINUM STOREFRONT 1" INSULATED GLASS EXISTING FLOOR LINE 6" REFER TO PARTITION TYPE FOR WALL CONSTRUCTION DOUBLE METAL STUD FRAMING CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME 2"SEE SCHEDULE REFER TO PARTITION TYPE FOR WALL CONSTRUCTION DOUBLE METAL STUD FRAMING CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME 2" SEE SCHEDULE F SEE SCHED. SEE SCHED. 1 2" SEE SCHED. 2"SEE SCHED.2" EXTEND FROM TOP OF WALL BASE TO CEILING 2" 2" ACROVYN CORNER GUARD ACOUSTICAL LAY-IN CEILING 5/8" GYPSUM BOARD 3 5/8" METAL STUD ACOUSTICAL LAY-IN CEILING BOTTOM OF BULKHEAD SEE REFLECTED CEILING PLAN ACOUSTICAL LAY-IN CEILING 5/8" GYPSUM BOARD 3 5/8" METAL STUD ACOUSTICAL LAY-IN CEILING BOTTOM OF BULKHEAD EXISTING CONSTRUCTION CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME 2" SEE SCHEDULE EXISTING CONSTRUCTION CONTINUOUS SEALANT (BOTH SIDES) HOLLOW METAL DOOR FRAME 2"SEE SCHEDULE 1 0 5 .0 0 ° R 1 /4 " 1/4" 1 1/4" 1 1/2" 3/8" 1" 2" LAMINATE CABINET DOOR LAMINATE BULKHEAD 3/4" LAMINATE ACCESS PANEL ON Z-CLIPS. PL-1, REFER TO CASEWORK ELEVATIONS. CONCEAL FASTENERS. SUPPORT AT CASEWORK 4"H SOLID SURFACE BACKSPLASH - SS-1 SOLID SURFACE COUNTER - SS-1 PLASTIC LAMINATE APRON - PL-1, REFER TO CASEWORK ELEVATIONS CLEAR KNEE SPACE MAX 6" 9" MIN 11" 8" 2' - 1" 1 1/2"1" 2' - 10" MAX 29" MIN 27" MIN EXISTING FULL GLAZING SYSTEM RELOCATED EXISTING CEILING WOOD BLOCKING STEEL STRUCTURE TO DECK (SUPPORT OF GLASS PANELS) ACOUSTICAL LAY-IN CEILING 1 5/8" METAL STUD FRAMING - EXTEND 12" ABOVE CEILING 5/8" GYPSUM BOARD 3' - 0" 6' - 8" EXISTING FULL-GLAZING SYSTEM TO BE RELOCATED 11' - 8" 8 ' - 0" EXISTING PIVOT HINGE EXISTING MAG LOCK EXISTING CYLINDER LOCK REMOVE PORTION OF EXISTING TRACK/SHOE REMOVE PORTION OF EXISTING OVERHEAD TRACK/SHOE 13 A7-1 DAVID ARCHI T E C T R E G I S TERED AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:43 PM Door Schedule and Typical Details A7-1 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of Door Hardware Schedule Outpatient Rehab Door and Opening Schedule Opening No. Door Frame Details Label Door Glass Hdw. Set RemarksSizeMat.Ele.Mat.Ele.Head Jamb Sill K176 4'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 --90 MIN --5 K177 3'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------4 K177C 8'-0" x 4'-8", M100 Manual Op. System, Jamb Mount ALUM 8/A10-2 ALUM 8/A10-2 6/A3-1 Face Mount 6/A3-1 ------- K178C 3'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------4 K178D 4'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------2 K178E 4'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------3 K179 3'-6" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------1 K183 4'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------2 K186 4'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------2 K187 3'-6" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------1 K188 4'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------2 K189 3'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------4 K190 4'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------3 K191 4'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------2 K192 4'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------2 K193 4'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------2 K194 4'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------2 K195 4'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------2 K196 4'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A7-1 4/A7-1 ------2 K198 3'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------1 K199 3'-0" x 7'-0" x 1 3/4"WD F HM 1 1/A7-1 2/A7-1 ------4 K200 3'-0" x 8'-0" x 1"Ex. GLASS FG HM 1 2/A2-2 --2/A2-2 Ex.Ex. K201 3'-0" x 7'-0" x 1 3/4"WD F HM 1 3/A2-2 4/A2-2 ------4 1 1/2" = 1'-0" Door Sill Detail5 1 1/2" = 1'-0" Door Jamb Detail1 1 1/2" = 1'-0" Door Head Detail2 Door ElevationsFrame Elevations 6" = 1'-0" Corner Guard Detail6 1 1/2" = 1'-0" Bulkhead Detail7 1 1/2" = 1'-0" Bulkhead Detail8 1 1/2" = 1'-0" Door Head Detail3 1 1/2" = 1'-0" Door Jamb Detail4 12" = 1'-0" Edge Profile9 3" = 1'-0" Cabinet / Soffit Detail10 1 1/2" = 1'-0" Counter Section11 REVISIONS DATE BY 1" = 1'-0" Glazing Wall Section13 1/4" = 1'-0" Relocated/Modified Glass Entry System12 1514.9 16 16.1 16.314131211.411.311109.99.7 A B C D LINEN CABINETS K185 TEP / EXAM 1 K191 EXAM 2 K192 EXAM 3 K193 EXAM 4 K194 EXAM 5 K195 STORAGE K198 ADULT CHARTING K199 ADULT GYM K197 Pt. TOILET K190 SPEECH K188 STORAGE K179 Pt. TOILET K178E STORAGE K187 FLEX ROOM 1 K186 PEDS GYM K178BREAK ROOM K181 PEDS EXAM 1 K178D EXAM 6 K178C 1 2 4 11 1 OFFICE K189 CONSULT K183 WORKROOM K177A RECEPTION K177 CORRIDOR K176A STORAGE K178A STORAGE K178B K172B AUDIO VIS K182 PUBLIC TOILET K172A WORK K170 SECURITY K170A OFFICE K170C OFFICEK170B SECURITY K172 CLASS K173 CLASS K1C09 CORRIDOR K1C10 ELEV LOBBY K174 CLASS K175 CLASS K1C06 ELEV LOBBY ELEV-2 ELEVATOR ELEV-3 ELEVATOR K180 PUBLIC TOILET 44444 5' - 0" TYP 3CORRIDOR K1C13 3 1 A.F.F. 9' - 7 1/2" .1' - 0" PASSAGE K178F 44 4 5 6 6 6 66 6 CORRIDOR K1C03 WAITING K200 OFFICE K201 EXAM 6 K196 WAITING K176 7 GYPSUM BOARD CEILING/BULKHEAD 1.REFER TO MEP FOR FIXTURE TYPES AND LOCATIONS. 2.ALL ACOUSTICAL LAY-IN CEILINGS AT 8'-9" A.F.F. UNLESS OTHERWISE NOTED. LAMINATE BULKHEAD 2' x 2' LAY-IN CEILING 2' x 4' LAY-IN CEILING GASKETED OR CLIPPED CEILING DAVID ARCHI T E C T R E G I S TERED AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:46 PM Reflected Ceiling Plan A9-1 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of 1/8" = 1'-0" First Floor Reflected Ceiling Plan Outpatient Rehab Specific Reflected Ceiling Plan Notes 1 EXISTING CEILING TO REMAIN. 2 3 5/8" METAL STUD FRAMING (@ 16" O.C.) W/ GYPSUM BOARD ON ALL SIDES. BOTTOM OF BULKHEAD TO BE 8' - 0" A.F.F. 3 3 5/8" METAL STUD FRAMING (@ 16" O.C.) W/ GYPSUM BOARD ON ALL SIDES. BOTTOM OF BULKHEAD TO BE 8' - 7" A.F.F. 4 CUBICAL CURTAIN TRACK AND CURTAIN. REFER TO FINISH SCHEDULE. 5 PLASTIC LAMINATE (PL-1) ACCESSIBLE ENCLOSURE AROUND OVERHEAD COILING DOOR. MOUNT SO THAT ENCLOSURE IS EASILY REMOVABLE. 6 NURSE CALL INDICATOR DOME LIGHT. CENTER ABOVE DOOR. 7 3 5/8" METAL STUD FRAMING (@ 16" O.C.) W/ GYPSUM BOARD ON ALL SIDES. BOTTOM OF BULKHEAD TO BE 7' - 8" A.F.F. PAINT BOTTOM AND SIDES PT-6. General Ceiling Plan Notes REVISIONS DATE BY LAMINATE BULKHEAD - PL-1 2' - 11"2' - 6"2' - 6"2' - 6"1' - 6" 1" FILLER 2' - 11"2' - 6"2' - 6"2' - 6"1' - 6" 1" FILLER PL-1 PL-1 PL-1 PL-1 PL-1 PL-1 PL-1 PL-1 SINK SOLID SURFACE COUNTER AND BACKSPLASH - SS-1 12' - 0" AP RESILIENT BASE - RB-1 12' - 0" PL-1 2' - 7 1/2" 2' - 6" 1' - 8" 2' - 10" 11 A7-1 2 1/2" FILLER 3' - 0"3' - 0"3' - 0"3' - 0" 2 3/8" FILLER 12' - 4 7/8" LAMINATE BULKHEAD - PL-1 PL-1PL-1PL-1PL-1 RESILIENT BASE - RB-1 7' - 0" LAMINATE BULKHEAD - PL-1 1" FILLER 4' - 0"4' - 0" 1" FILLER 8' - 2" PL-1 PL-1 RESILIENT BASE - RB-1 2' - 7 1/2" 7' - 0" INTERMEDIATE VERTICAL SUPPORTS 2' - 10" 1" FILLER 3' - 0"3' - 10 1/2"2' - 0"1' - 6"2' - 10 1/2" 1" FILLER 3' - 0"10' - 3" LAMINATE BULKHEAD - PL-1 PL-1 PL-1 SOLID SURFACE COUNTER AND BACKSPLASH - SS-1 1' - 9" 7' - 0" SINK 13' - 4" AP 13' - 4" RESILIENT BASE - RB-1 PLASTIC LAMINATE COUNTER AND BACKSPLASH - PL-2 2' - 6" PL-1 G 11 A7-1 S SINK PL-1 PL-1PL-1 PL-1 PL-1 1' - 9" 2' - 6" 1' - 8" 2' - 10" 13' - 7 1/2" 4' - 0"4' - 0"2' - 7"2' - 9" LAMINATE BULKHEAD - PL-1 1' - 9" 7' - 0" SOLID SURFACE COUNTER AND BACKSPLASH - SS-1 6' - 6 1/8"2' - 9"2' - 6" 1" FILLER 8' - 3 1/2" LAMINATE BULKHEAD - PL-1 AP RESILIENT BASE - RB-1 8' - 9" PL-1 1' - 0" 1" 42" OVERHEAD STORAGE BIN (FURNISHED & INSTALLED BYOWNER) 1" LAMINATE PANEL PLASTIC LAMINATE COUNTER AND BACKSPLASH - PL-2 RESILIENT BASE - RB-1 4' - 5" 8' - 9" S S S S S S 1' - 6" 2' - 6" 3' - 5 1/2"3' - 6"3' - 6"3' - 6"3' - 6"3' - 5 1/8" G G G G G G 3' - 5"1"3' - 5"1"3' - 5"1"3' - 5"1"3' - 5"1"3' - 6" PLASTIC LAMINATE COUNTER AND BACKSPLASH - PL-2 42" OVERHEAD STORAGE BIN (FURNISHED & INSTALLED BY OWNER) 1" LAMINATE PANEL RESILIENT BASE - RB-1 G S G G G G G S S S S S 1' - 6" 2' - 6" 4' - 5" 8' - 9" 3' - 6"1"3' - 5"1"3' - 5"1"3' - 5"1"3' - 5"1"3' - 5" 3' - 5 1/8"3' - 6"3' - 6"3' - 6"3' - 6"3' - 5 1/2" PL-1 PL-1 2' - 10" 8' - 9" 1" FILLER 2' - 6"2' - 3" 1" FILLER4' - 11" PRINTER RESILIENT BASE - RB-1 PLASTIC LAMINATE COUNTER AND BACKSPLASH - PL-2 DAVID ARCHI T E C T R E G I S TERED AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:48 PM Casework Elevations A10-1 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of 1/2" = 1'-0" Casework Elevation1 1/2" = 1'-0" Casework Elevation2 1/2" = 1'-0" Casework Elevation3 1/2" = 1'-0" Casework Elevation4 1/2" = 1'-0" Casework Elevation5 1/2" = 1'-0" Casework Elevation6 1/2" = 1'-0" Casework Elevation7 1/2" = 1'-0" Casework Elevation8 TYPICAL EXAM ROOM - K186, K188, K191, K192 PEDS GYM - K178 PEDS GYM - K178 LINENS CABINET - K185 ADULT GYM - K197 ADULT CHARTING - K199 ADULT CHARTING - K199 ADULT CHARTING - K199 REVISIONS DATE BY 15' - 1 1/2"4' - 11 1/2"4' - 9 1/2" 24' - 10 1/2" 2' - 10" 5' - 11" 8' - 9 " FURNITURE FILE DRAWER (MOBILE)PL-1 PL-1 15' - 1 1/2" PRINTER 42" OVERHEAD STORAGE BIN (FURNISHED & INSTALLED BYOWNER) 4' - 5" 8' - 9" 1" LAMINATE PANEL PLASTIC LAMINATE COUNTER AND BACKSPLASH - PL-2 RESILIENT BASE - RB-1 S G G G G 3' - 8 1/2"3' - 9"3' - 9"3' - 11" S S 2 ' - 6" 1 ' - 6"3' - 8" 1" 3' - 8" 1" 3' - 8" 1" 3' - 10 1/2" 1 3/4" FILLER 2' - 3"2' - 3" 1 3/4" FILLER4' - 9 1/2" FURNITURE FILE DRAWER (MOBILE) 42" OVERHEAD STORAGE BIN (FURNISHED & INSTALLED BYOWNER) 1" LAMINATE PANEL PLASTIC LAMINATE COUNTER AND BACKSPLASH - PL-2 RESILIENT BASE - RB-1 S SSSS 1' - 6" 2' - 6" 4' - 5" 8' - 9" 3' - 7 1/8"3' - 9"3' - 9"3' - 9"3' - 8 1/2" 18' - 8" 3' - 8" 1" 3' - 8" 1" 3' - 8" 1" 3' - 8" 1" 3' - 8" G G G G G REFRIGERATOR SOLID SURFACE COUNTER AND BACKSPLASH - SS-1 PL-1 PL-1 MICROWAVE LAMINATE BULKHEAD - PL-1 1' - 9" 2' - 6" 1' - 8" 2' - 10" 8' - 9" 3' - 8"3' - 0"3' - 2 1/8" 9' - 10 1/8" SINK AP PL-1 ADJ. SHELF 2' - 8"2' - 6"1' - 6" 6' - 8"3' - 2 1/8" RESILIENT BASE - RB-1 LAMINATE BULKHEAD - PL-1 PL-1 PL-1 PL-1 PL-1 PL-1 PL-1 8' - 9" 1" FILLER 2' - 6"2' - 6"2' - 6"5' - 9 1/8" 13' - 4 1/8" PLASTIC LAMINATE COUNTER AND BACKSPLASH - PL-2 1' - 9" 2' - 6" 1' - 8" 2' - 10" COPIER/PRINTER1" 1" FILLER 2' - 6"2' - 6"2' - 6" 7' - 7" RESILIENT BASE - RB-1 LAMINATE BULKHEAD - PL-1 PL-1 PL-1 PL-1 PL-1 SOLID SURFACE COUNTER AND BACKSPLASH - SS-2SOLID SURFACE COUNTER - SS-2 1' - 9" 2' - 6" 2' - 0" 2' - 6" 8' - 9" PL-1 2" FILLER 1' - 9"2' - 6"2' - 6" 2 1/8" FILLER 13' - 4 1/8" 4' - 5"2' - 6" 2" FILLER7' - 1" 4' - 0" 2' - 6" 4"4' - 0"1' - 6 1/4" F RESILIENT BASE - RB-1 8' - 0" 1" FILLER 1' - 6"4' - 3 1/4" 5' - 10 1/4" G G SLIDING GLASS WINDOW W/ LATCH/LOCK 9" 1' - 6" 4' - 0" 2' - 6" 1' - 6 1/4"5' - 10 1/4" 5' - 10 1/4" SOLID SURFACE COUNTER - SS-2 8' - 9" GYPSUM BOARD BULKHEAD RESILIENT BASE - RB-1 1' - 6 1/4"4' - 0"4" SLIDING GLASS WINDOW w/ LATCH/LOCK 1/2" DRYWALL REVEAL (SIMILAR TO FRY-REGLET #DRM-50-625) 1' - 6 1/4" 2' - 4 1/2"1/2" DRYWALL REVEAL (SIMILAR TO FRY-REGLET #DRM-50-625) 1/2" DRYWALL REVEAL (SIMILAR TO FRY-REGLET #DRM-50-625) REVEALS CONTINUE ON SIDE/WING WALL REVEALS CONTINUE ON SIDE/WING WALL SOLID SURFACE COUNTER - SS-2 11 1/4"3' - 4"2' - 2 3/4" 6' - 6" 7' - 2" 3' - 8" 3' - 6" 3' - 8" SLIDING GLASS WINDOW W/ LATCH/LOCK 11' - 7 1/2" 2' - 1"9' - 6 1/2" 2' - 6" 2' - 0 " 2' - 6" 1' - 9" COILED OVERHEAD DOOR SOLID SURFACE COUNTER - SS-2 5 A3-1 6 A3-1 S EQ EQ EQ S 3' - 6" 4' - 1" G G PLASTIC LAMINATE (PL-1) ACCESS HOUSING ENCLOSURE. ENCLOSURE TO RUN FROM SIDE WALL TO SIDE WALL w/ ACCESSIBLE CLIPS. CONTRACTOR TO COORDINATE DESIGN w/ OVERHEAD COILING DOOR UNIT. 8' - 0" 4' - 6"OPEN LAMINATE BULKHEAD - PL-1 PL-1 PL-1 PL-1 PL-1 SOLID SURFACE COUNTER - SS-2 1" FILLER 2' - 6"1' - 9" 2" 2' - 0" 6' - 6" 2' - 6" 2' - 0" 2' - 6" 7' - 0" 1" FILLER 2' - 6"2' - 6" RESILIENT BASE - RB-1 5 A3-1 6 A3-1 2' - 6"3' - 6" 4" 3" 6" 6" 3" 6" 4" 4" 7' - 9 1/2" 9 1/2" 7' - 0 " 1" SOLID SURFACE COUNTER - SS-2 EXISTING CONSTRUCTION +/- 2' - 8"4' - 0"4' - 0"2' - 11" 1/2" EQUAL 1/2" EQUAL 1/2" 1/2" PLASTIC LAMINATE (PL-1) ACCENT PANELS w/ 1/2" REVEALS 1/2" DRYWALL REVEAL (SIMILAR TO FRY-REGLET #DRM-50-625)8' - 0" 4' - 6" OPEN DAVID ARCHI T E C T R E G I S TERED AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:50 PM Casework Elevations A10-2 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of 1/2" = 1'-0" Casework Elevation1 1/2" = 1'-0" Casework Elevation2 1/2" = 1'-0" Casework Elevation3 1/2" = 1'-0" Casework Elevation4 1/2" = 1'-0" Casework Elevation5 1/2" = 1'-0" Casework Elevation6 1/2" = 1'-0" Casework Elevation7 1/2" = 1'-0" Casework Elevation8 1/2" = 1'-0" Casework Elevation9 1/2" = 1'-0" Casework Elevation10 PEDS CHARTING - K178C PEDS CHARTING - K178C BREAK ROOM - K181 WORKROOM - K177A RECEPTION - K177 RECEPTION - K177 RECEPTION - K177 RECEPTION - K177 RECEPTION - K177 RECEPTION - K177 REVISIONS DATE BY ADULT GYM K197 EXAM 5 K195 EXAM 4 K194 EXAM 3 K193 EXAM 2 K192 TEP / EXAM 1 K191 Pt. TOILET K190 SPEECH K188 STORAGE K187 FLEX ROOM 1 K186 STORAGE K179 Pt. TOILET K178E LINEN CABINETS K185 PEDS GYM K178 PEDS EXAM 1 K178D BREAK ROOM K181 EXAM 6 K178C ADULT CHARTING K199 STORAGE K198 5' x 6' THERAPY MAT 5' x 6' THERAPY MAT OFFICE K189 CONSULT K183 CORRIDOR K176A WORKROOM K177A RECEPTION K177 STORAGE K178A STORAGE K178B K172B AUDIO VIS K182 PUBLIC TOILET K172A WORK K170 SECURITY K170A OFFICE K170C OFFICEK170B SECURITY K172 CLASS K173 CLASS K1C09 CORRIDOR K1C10 ELEV LOBBY K174 CLASS K175 CLASS K1C06 ELEV LOBBY ELEV-2 ELEVATOR ELEV-3 ELEVATOR K180 PUBLIC TOILET K1C03 CORRIDOR PASSAGE K178F PT-3 PT-4 PT-5 PT-4 PT-5 PT-3 PT-4 PT-5 PT-3 PT-3PT-2 PT-2 PT-5 PT-3 PT-3 PT-4 PT-3 PT-2 PT-2 PT-2 PT-6 PT-6 CG CG CG CG CG CG CG CG CG CG CGCG CG CGCG CG CPT CPT CPT CPT CPT CPT CPT CPT CPT CPT CPT CPT CP T CPT CPT CPT CPT CPT CPT CPT CPT CPT VWC-1 (ATTIC STOCK) - INFILL PT-2 PT-2 PT-2 CPT CPT EXAM 6 K196 WAITING K176 CORRIDOR K1C13 WAITING K200 OFFICE K201 FLOORS CARPET TILE CPT-1 - MANNINGTON; SCENA; BORA BORA 8103. MONOLITHIC INSTALLATION. RUBBER TILE RT-1 - MOHAWK MEDIFLEX TILE; MOUNTAIN PATH TRST-23 RT-2 - MOHAWK MEDIFLEX TILE; GREEN APPLE TRST-38 RT-3 - MOHAWK MEDIFLEX TILE; CHEDDAR TRST-37 RT-4 - MOHAWK MEDIFLEX TILE; GEMSTONE TRST-29 CERAMIC TILE CT-1 - CROSSVILLE; EMPIRE SERIES; 14" x 14"; VS81 PALAIS TAUPE BASE RESILIENT BASE RB-1 - JOHNSONITE; 4" VINYL COVE BASE; 29 MOON ROCK CERAMIC TILE BASE CTB-1 - CROSSVILLE; EMPIRE SERIES; 6" x 14" COVE BASE; VS81 PALAIS TAUPE WALLS PAINT PT-1 - SHERWIN WILLIAMS; PANDA WHITE SW6147 PT-2 - SHERWIN WILLIAMS; VIRTUAL TAUPE SW7039 PT-3 - SHERWIN WILLIAMS; HARVESTER SW6373 PT-4 - SHERWIN WILLIAMS; SHAGREEN SW6422 PT-5 - SHERWIN WILLIAMS; DRIZZLE SW6479 PT-6 - SHERWIN WILLIAMS; BALANCED BEIGE SW7038 VINYL WALLCOVERING (ATTIC STOCK) VWC-1 - LEN-TEX; CORONADO SANDSTONE (ATTIC STOCK). CEILINGS ACOUSTICAL TILE CEILING ACT-1 - EQUAL TO ARMSTRONG DUNE 15/16 GRID; 24" x 24"; 1772 CASEWORK PLASTIC LAMINATE (CASEWORK, COUNTERS) PL-1 - PIONITE; MILLWORK CHERRY; SUEDE FINISH; WC431 PL-2 - FORMICA; ASHEN CERAMIC; MATTE FINISH; 7698-58 (PRODUCT TO BE DISCONTINUED. IF NOT ENOUGH STOCK IS AVAILABLE, SUBSTITUTE PIONITE IL PALIO PAPEL AV981 FOR PL-2) SOLID SURFACE COUNTERTOPS SS-1 - CORIAN; FOSSIL SS-2 - CORIAN; ANTRACITE FABRIC CUBICLE CURTAIN CC-1 - MAHARAM PEER 511463, 006 TROPICAL (SEE FINISH SCHEDULE FOR LOCATION) 1.SEE FINISH FLOOR PLAN FOR DIRECTION OF CARPET. PLANK DIRECTION INDICATED BY ARROWS. 2.SEE FINISH FLOOR PLAN FOR ACCENT WALL LOCATION. 3.SEE ELEVATIONS FOR CASEWORK DETAILS. 4.RUBBER TILE TO BE INSTALLED IN RANDOM PATTERN. 40% RT-1; 20% EACH FOR RT-1, RT-2, RT-3. 5.PAINT TO BE EPOXY AND SEMI-GLOSS. 6.FABRICATE AND INSTALL CUBICLE CURTAIN CC-1 PER HOSPITAL STANDARDS AND WHERE LOCATED ON REFLECTED CEILING PLAN. 7.PAINT BULKHEAD ABOVE RECEPTION DESK PT-6. SEE FIRST FLOOR FLECTED CEILING PLAN - HR ON SHEET A2-2. 8.SEE FLOOR PLAN FOR ACCENT WALL PAINT LOCATIONS AND CARPET DIRECTION. 9.PATCH INFILLED CONTRUCTION TO MATCH ADJACENT EXISTING. 10.PATCH INFILL EAST WALL OF CORRIDOR AT DOOR INFILL AND REMOVALS WITH OWNER ATTIC STOCK VINYL WALL COVER (VWC-1). (APPLICABLE THROUGHOUT ALL AREAS OF CONSTRUCTION) A.FOR ALL FLOORING MATERIALS INSTALLED ON GRADE OR BELOW GRADE: THE FLOORING CONTRACTOR SHALL BE RESPONSIBLE TO INCLUDE IN THEIR BID PRICES ALL REQUIRED MATERIALS AND LABOR FOR A COMPLETE INSTALLATION THAT MEETS THE MANUFACTURER'S TOTAL SYSTEM PERFORMANCE. THIS INCLUDES ALL PREP MATERIALS AND LABOR REQUIRED TO MEET MANUFACTURER'S WRITTEN SPECIFICATIONS FOR MOISTURE, PH, SMOOTHNESS OR LEVELNESS OR CLEANLINESS OF NEW OR EXISTING SUBSTRATES, ETC. THIS INSTALLATION SHALL INCLUDE THE MANUFACTURER'S SPECIFIED ADHESIVES, SEALERS, ETC. B.PAINT ALL HOLLOW METAL DOORS, WINDOW FRAMES, AND DOOR FRAMES PT-6, SEMI-GLOSS. C.GROUT TO BE EPOXY, COLOR BY ARCHITECT. D.ALL OUTSIDE DRYWALL CORNERS IN PUBLIC AREAS TO RECEIVE HIGH IMPACT CORNER GUARDS. MARKED ON FINISH FLOOR PLAN AS 'CG'. HEIGHT, FLANGE AND COLOR TO MATCH EXISTING. E.PATCH AND MATCH ALL FINISHES DUE TO CONSTRUCTION. F.SEE REFLECTED CEILING PLAN AND DETAILS FOR LOCATION AND HEIGHT OF CEILINGS. G.EVERY TRANSITIONS BETWEEN FLOORING MATERIALS TO BE FLUSH. IT IS FLOORING CONTRACTOR'S RESPONSIBILITY TO LEVEL SUBSTRATE AS NECESSARY FOR MATERIALS TO TRANSITION AT LEVEL HEIGHT, INCLUDING GRINDING OR BUILDING UP OF CONCRETE. ALL TRANSITION STRIPS TO BE STAINLESS STEEL EQUAL TO SCHLUTER SYSTEMS AND MUST MEET ADA; ALL PROFILES TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. TRANSITION STRIPS ARE UNNECESSARY BETWEEN LIKE MATERIALS (CARPET TO CARPET, LINOLEUM TO VINYL, ETC). H.PAINT VENTS, DIFFUSERS, ELECTRICAL PANELS, FIRE CABINETS (UNLESS THEY ARE NATURAL ALUMINUM OR STAINLESS STEEL), ETC. TO MATCH WALL COLOR. DAVID ARCHI T E C T R E G I S TERED AR10500075 STATE OF I IND A AN No. SL T A E R N I C H LOAS Architecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337 930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBER SET DESCRIPTION PROJECT NO.DATE 6777 09-23-15 MSKTD& Associates Indiana University North Hospital - Outpatient Rehab 9/22/2015 4:52:54 PM Room Finish Plan A11-1 11700 N. Meridian Street | Carmel, Indiana 46032 Renovation of 1/8" = 1'-0" First Floor Finish Plan Outpatient Rehab Room Finish Schedule Room No.Name Floor Base Walls Walls Walls Walls Ceiling Type (see RCP for heights)RemarksNESW K1C03 CORRIDOR EXT EXT EXT EXT EXT EXT EXT 9 K1C13 CORRIDOR CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 1 K176 WAITING CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 1 K176A CORRIDOR CPT-1 RB-1 PT-1 PT-3 PT-1 PT-1 ACT-1 1,2 K177 RECEPTION CPT-1 RB-1 PT-1,PT-2 PT-1 PT-1 PT-1,PT-2 ACT-1 1,2,3 K177A WORKROOM CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 1,3 K178 PEDS GYM SR-1,SR-2,SR-3,SR-4RB-1 PT-1 PT-1,PT-5 PT-1,PT-3 PT-1,PT-4 ACT-1 2,3,4 K178A STORAGE EXT EXT PT-1 PT-1 PT-1 PT-1 EXT - K178B STORAGE EXT EXT PT-1 PT-1 PT-1 PT-1 EXT - K178C EXAM 6 CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 1,3 K178D PEDS EXAM 1 CPT-1 RB-1 PT-1 PT-1 PT-4 PT-1 EXT 1,2 K178E Pt. TOILET CT-1 CTB-1 PT-6 PT-1 PT-1 PT-1 ACT-1 2,5 K178F PASSAGE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 1 K179 STORAGE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 1 K181 BREAK ROOM CPT-1 RB-1 PT-1 PT-2 PT-1 PT-1 ACT-1 1,2,3 K183 CONSULT CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 ACT-1 1,2 K185 LINEN CABINETS CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 1 K186 FLEX ROOM 1 CPT-1 RB-1 PT-1 PT-5 PT-1 PT-1 ACT-1 1,2,3 K187 STORAGE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 1 K188 SPEECH CPT-1 RB-1 PT-1 PT-3 PT-1 PT-1 ACT-1 1,2,3 K189 OFFICE CPT-1 RB-1 PT-1 PT-2 PT-1 PT-1 ACT-1 1,2 K190 Pt. TOILET CT-1 CTB-1 PT-1 PT-6 PT-1 PT-1 ACT-1 2,5 K191 TEP / EXAM 1 CPT-1 RB-1 PT-1 PT-1 PT-4 PT-1 ACT-1 1,2,3,6 K192 EXAM 2 CPT-1 RB-1 PT-5 PT-1 PT-1 PT-1 ACT-1 1,2,3,6 K193 EXAM 3 CPT-1 RB-1 PT-1 PT-1 PT-3 PT-1 EXT 1,2,3,6 K194 EXAM 4 CPT-1 RB-1 PT-4 PT-1 PT-1 PT-1 EXT 1,2,3,6 K195 EXAM 5 CPT-1 RB-1 PT-1 PT-1 PT-5 PT-1 EXT 1,2,3,6 K196 EXAM 6 CPT-1 RB-1 PT-1 PT-1 PT-3 PT-1 ACT-1 2,3,6 K197 ADULT GYM CPT-1 RB-1 PT-1 PT-1 PT-1 PT-3 ACT-1 2,3,6 K198 STORAGE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 - K199 ADULT CHARTING CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 3 K200 WAITING CPT-1 RB-1 PT-1 PT-2 PT-1 PT-1 ACT-1 1,7,8 K201 OFFICE CPT-1 RB-1 PT-1 PT-2 PT-1 PT-1 ACT-1 1,8 Color Legend Specific Remarks General Remarks REVISIONS DATE BY 2 S E A T S 5' x 6 ' TH E R A P Y MA T 5' x 6 ' TH E R A P Y MA T AD U L T G Y M K1 9 7 EX A M 5 K1 9 5 EX A M 4 K1 9 4 EX A M 3 K1 9 3 EX A M 2 K1 9 2 TE P / E X A M 1 K1 9 1 Pt . T O I L E T K1 9 0 SP E E C H K1 8 8 ST O R A G E K1 8 7 FL E X R O O M 1 K1 8 6 ST O R A G E K1 7 9 Pt . T O I L E T K1 7 8 E LINEN CABINETS K185 PEDS GYM K178 PE D S E X A M 1 K1 7 8 D BR E A K R O O M K1 8 1 PE D S C H A R T I N G K1 7 8 C OF F I C E K2 0 1 T C H A R T I N G K1 9 9 EX A M 6 K1 9 6 ST O R A G E K1 9 8 WA I T I N G K2 0 0 CO R R I D O R K1 7 6 A CO N S U L T K1 8 3 OF F I C E K1 8 9 WO R K R O O M K1 7 7 A WA I T I N G K1 7 6 RE C E P T I O N K1 7 7 STORAGE K178BSTORAGEK178A 15 14 . 9 1 6 1 6 . 1 1 6 . 3 14 13 A B C D V 2 " ø V 2"ø V 2 " ø V 1 1/2"ø V 1 1 / 2 " ø DC W 1 / 2 " ø DH W 3 / 4 " ø DH W R 3 / 4 " ø V 2 " ø DH W 1 / 2 " ø DC W 1 1 / 2 " ø DC W 2 " ø DH W 1 1 / 2 " ø DH W R 3 / 4 " ø V 2 " ø DH W 1 / 2 " ø DC W 1 / 2 " ø V 2 " ø V 2 " ø V 2 " ø DH W 1 / 2 " ø DC W 1 / 2 " ø DC W 1 / 2 " ø V 2 " ø DC W 1 / 2 " ø DH W 1 / 2 " ø DH W R 3 / 4 " ø DH W 3 / 4 " ø DC W 3 / 4 " ø ScaleArchitecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBERSET DESCRIPTIONPROJECT NO.DATEMSKTD& Associates PRELIMINARYNOT FOR CONSTRUCTION REVISIONSDATEBY 9/15/2015 11:27:43 AM 11725 Illinois Street, MOB Suite 350 I Carmel,Indiana46032Renovation of 1/4" = 1'-0"Project Number09/17/15 P-1001st Floor Plumbing 12 S E A T S 5' x 6 ' TH E R A P Y MA T 5' x 6 ' TH E R A P Y MA T AD U L T G Y M K1 9 7 EX A M 5 K1 9 5 EX A M 4 K1 9 4 EX A M 3 K1 9 3 EX A M 2 K1 9 2 TE P / E X A M 1 K1 9 1 Pt . T O I L E T K1 9 0 SP E E C H K1 8 8 ST O R A G E K1 8 7 FL E X R O O M 1 K1 8 6 ST O R A G E K1 7 9 Pt . T O I L E T K1 7 8 E LINEN CABINETS K185 PEDS GYM K178 PE D S E X A M 1 K1 7 8 D BR E A K R O O M K1 8 1 PE D S C H A R T I N G K1 7 8 C OF F I C E K2 0 1 DU L T C H A R T I N G K1 9 9 EX A M 6 K1 9 6 ST O R A G E K1 9 8 WA I T I N G K2 0 0 CO R R I D O R K1 7 6 A CO N S U L T K1 8 3 OF F I C E K1 8 9 WO R K R O O M K1 7 7 A WA I T I N G K1 7 6 RE C E P T I O N K1 7 7 STORAGE K178BSTORAGEK178A 15 14 . 9 1 6 1 6 . 1 1 6 . 3 14 13 A B C D DC W 1 / 2 " ø DH W 3 / 4 " ø DH W R 3 / 4 " ø DH W 3 / 4 " ø DC W 3 / 4 " ø DC W 2 " ø DH W 1 1 / 2 " ø DH W R 3 / 4 " ø DC W 1 / 2 " ø DH W 1 / 2 " ø DH W R 3 / 4 " ø DH W 3 / 4 " ø DC W 1 " ø DC W 1 / 2 " ø DH W 1 / 2 " ø DC W 1 / 2 " ø DH W 1 / 2 " ø 0' - 6 " DC W 1 / 2 " ø DC W 1 / 2 " ø DH W 1 / 2 " ø DC W 1 / 2 " ø DH W 1 / 2 " ø DC W 1 / 2 " ø DH W 1 / 2 " ø DC W 3 / 4 " ø DH W R 3 / 4 " ø DH W 3 / 4 " ø .7 5 G P M .2 5 G P M Ne w p i p i n g t o S K - 3 Ne w p i p i n g t o R e s t r o o m Ne w p i p i n g t o S K - 3 Ne w p i p i n g t o S K - 3 New piping to Restrooms and SK-3 Ne w p i p i n g t o S K - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 La v . - 3 WC - 2 La v . - 3 WC - 4 DC W 1 1 / 2 " ø DH W 1 / 2 " ø DC W 1 1 / 2 " ø DH W 1 / 2 " ø DC W 1 / 2 " ø 1' - 3 " 1' - 0 " 1' - 0" 0' - 5 27/32" 0' - 8 " 1' - 2 " DH W 1 / 2 " ø DC W 3 / 4 " ø 0' - 8 " 0' - 8 " 8' - 1 1 5 / 1 6 " ScaleArchitecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBERSET DESCRIPTIONPROJECT NO.DATEMSKTD& Associates PRELIMINARYNOT FOR CONSTRUCTION REVISIONSDATEBY 9/15/2015 11:27:43 AM 11725 Illinois Street, MOB Suite 350 I Carmel,Indiana46032Renovation of 1/4" = 1'-0"Project Number09/17/15 P-101Domestic Hot and Cold ScaleArchitecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBERSET DESCRIPTIONPROJECT NO.DATEMSKTD& Associates PRELIMINARYNOT FOR CONSTRUCTION REVISIONSDATEBY 9/15/2015 11:27:43 AM 11725 Illinois Street, MOB Suite 350 I Carmel,Indiana46032Renovation of Project Number09/17/15 P-102Domestic Hot and Cold Iso1/2" = 1' - 0" 12 S E A T S 5' x 6 ' TH E R A P Y MA T 5' x 6 ' TH E R A P Y MA T AD U L T G Y M K1 9 7 EX A M 5 K1 9 5 EX A M 4 K1 9 4 EX A M 3 K1 9 3 EX A M 2 K1 9 2 TE P / E X A M 1 K1 9 1 Pt . T O I L E T K1 9 0 SP E E C H K1 8 8 ST O R A G E K1 8 7 FL E X R O O M 1 K1 8 6 ST O R A G E K1 7 9 Pt . T O I L E T K1 7 8 E LINEN CABINETS K185 PEDS GYM K178 PE D S E X A M 1 K1 7 8 D BR E A K R O O M K1 8 1 PE D S C H A R T I N G K1 7 8 C OF F I C E K2 0 1 DU L T C H A R T I N G K1 9 9 EX A M 6 K1 9 6 ST O R A G E K1 9 8 WA I T I N G K2 0 0 CO R R I D O R K1 7 6 A CO N S U L T K1 8 3 OF F I C E K1 8 9 WO R K R O O M K1 7 7 A WA I T I N G K1 7 6 RE C E P T I O N K1 7 7 STORAGE K178BSTORAGEK178A 15 14 . 9 1 6 1 6 . 1 1 6 . 3 14 13 A B C D Sa n 2 " ø Sa n 2 " ø Sa n 2 " ø Sa n 2 " ø Sa n 1 1 / 2 " ø San 2"ø Ti e i n t o E x i s t i n g T o i l e t Ti e i n t o E x i s t i n g 4 " S a n i t a r y Ti e i n t o E x i s t i n g 4 " Ti e i n t o E x i s t i n g 4 " S a n i t a r y Ti e i n t o E x i s t i n g 4 " S a n i t a r y Ti e i n t o E x i s t i n g 4 " S a n i t a r y Sa n 4 " ø San 4"ø CO CO CO 9' - 3 " 1' - 6 " 1' - 6 " 1' - 6 " 1' - 1 5 / 8 " 1' - 6 " 1' - 6" 1' - 2 3/4" 1' - 2 1/2" 10 ' - 8 2 1 / 3 2 " 1' - 1 " WC - 4 La v . - 3 WC - 2 La v . - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 SK - 3 ScaleArchitecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBERSET DESCRIPTIONPROJECT NO.DATEMSKTD& Associates PRELIMINARYNOT FOR CONSTRUCTION REVISIONSDATEBY 9/15/2015 11:27:43 AM 11725 Illinois Street, MOB Suite 350 I Carmel,Indiana46032Renovation of 1/4" = 1'-0"Project Number09/17/15 P-103Sanitary Waste 12 S E A T S 5' x 6 ' TH E R A P Y MA T 5' x 6 ' TH E R A P Y MA T AD U L T G Y M K1 9 7 EX A M 5 K1 9 5 EX A M 4 K1 9 4 EX A M 3 K1 9 3 EX A M 2 K1 9 2 TE P / E X A M 1 K1 9 1 Pt . T O I L E T K1 9 0 SP E E C H K1 8 8 ST O R A G E K1 8 7 FL E X R O O M 1 K1 8 6 ST O R A G E K1 7 9 Pt . T O I L E T K1 7 8 E LINEN CABINETS K185 PEDS GYM K178 PE D S E X A M 1 K1 7 8 D BR E A K R O O M K1 8 1 PE D S C H A R T I N G K1 7 8 C OF F I C E K2 0 1 DU L T C H A R T I N G K1 9 9 EX A M 6 K1 9 6 ST O R A G E K1 9 8 WA I T I N G K2 0 0 CO R R I D O R K1 7 6 A CO N S U L T K1 8 3 OF F I C E K1 8 9 WO R K R O O M K1 7 7 A WA I T I N G K1 7 6 RE C E P T I O N K1 7 7 STORAGE K178BSTORAGEK178A 15 14 . 9 1 6 1 6 . 1 1 6 . 3 14 13 A B C D V 2"ø V 2 " ø V 2"ø V 2 " ø V 2"ø V 2 " ø V 2"ø V 2 " ø V 1 1/2"ø V 2"ø 1' - 6 " 1' - 3 5/8"9' - 3 7 / 8 " 9' - 6 " 1' - 5 3 / 4 " 1' - 0 5/16" 1' - 1 5 / 8 " 1' - 2 3/4"4' - 3 " 1' - 1" ScaleArchitecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBERSET DESCRIPTIONPROJECT NO.DATEMSKTD& Associates PRELIMINARYNOT FOR CONSTRUCTION REVISIONSDATEBY 9/15/2015 11:27:43 AM 11725 Illinois Street, MOB Suite 350 I Carmel,Indiana46032Renovation of 1/4" = 1'-0"Project Number09/17/15 P-104Sanitary Vent ScaleArchitecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBERSET DESCRIPTIONPROJECT NO.DATEMSKTD& Associates PRELIMINARYNOT FOR CONSTRUCTION REVISIONSDATEBY 9/15/2015 11:27:43 AM 11725 Illinois Street, MOB Suite 350 I Carmel,Indiana46032Renovation of Project Number09/17/15 P-105Sanitary Wast and Vent Iso1/2" = 1' - 0" V 2 " ø V 2 " ø V 1 1 / 2 " ø San 1 1/2"ø Sa n 1 1 / 2 " ø V 1 1 / 2 " ø V 2 " ø V 2 " ø Sa n 2 " ø Sa n 1 1 / 2 " ø Sa n 1 1 / 2 " ø Sa n 2 " ø V 1 1 / 2 " ø V 2 " ø V 2 " ø Sa n 2 " ø Sa n 3 " ø Sa n 4 " ø Sa n 2 " ø Sa n 3 " ø Sa n 2 " ø V 1 1 / 2 " ø ScaleArchitecture | Engineering | Interior Design 1715 Magnavox Way Fort Wayne, IN 46804 260.432.9337930 North Meridian Indianapolis, IN 46204 317.917.1190 www.msktd.com CERTIFICATION SHEET TITLE SHEET NUMBERSET DESCRIPTIONPROJECT NO.DATEMSKTD& Associates PRELIMINARYNOT FOR CONSTRUCTION REVISIONSDATEBY 9/15/2015 11:27:43 AM 11725 Illinois Street, MOB Suite 350 I Carmel,Indiana46032Renovation of Project Number09/17/15 P-106Sanitary Waste and Vent Detail 1 Sa n i t a r y W a s t e a n d V e n t d e t a i l E x a m 1 a n d Ex a m 2 2 Sa n i t a r y W a s t e a n d V e nt D e t a i l P t . T o i l e t 17 8 , P e d s G y m a n d F l e x R o o m 1 1/2" = 1'- 0"