HomeMy WebLinkAbout4522_0007_LIBERTYFUND_BIDPACK2_DRAWINGS_08282015_2NOT FOR CONSTRUCTION
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
PRELIMINARY
NOT FOR
CONSTRUCTION
Date:Issue:
8/
2
8
/
2
0
1
5
9
:
3
8
:
0
5
P
M
C:
\
U
s
e
r
s
\
T
A
l
l
e
n
\
D
o
c
u
m
e
n
t
s
\
4
5
2
2
-
0
0
7
_
L
i
b
e
r
t
y
F
u
n
d
-
C
E
N
T
R
A
L
_
T
O
N
Y
_
L
O
CA
L
_
0
7
2
9
2
0
1
5
.
r
v
t
45
2
2
-
0
0
0
7
/
B
I
D
P
A
C
K
A
G
E
#
2
/
0
8
/
2
8
/
1
5
CARMEL, INDIANA
08/28/15
BID PACKAGE #2
LIBERTY FUND HEADQUARTERS
002
LI
B
E
R
T
Y
F
U
N
D
H
E
A
D
Q
U
A
R
T
E
R
S
CA
R
M
E
L
,
I
N
D
I
A
N
A
08/28/15 / BID PACKAGE #2
COVER SHEET -
VOLUME 2
4522-0007
08/28/15
JMS
ER
LIBERTY FUND HEADQUARTERS
LIBERTY FUND
111th AND PENNSYLVANIA STREET
CARMEL, INDIANA 46032
111th AND PENNSYLVANIA STREET
Liberty Fund
8335 Allison Point Trail, Suite 300
Indianapolis, Indiana 46250
317-842-0880
Owner
Rowland Design, Inc.
702 North Capitol Avenue
Indianapolis, Indiana 46250
317-636-3980
Architecture / Landscape / Interior Design
Enverity Engineering
9229 Delegates Row, Suite 150
Indianapolis, Indiana 46240
317-706-2075
Site / Civil Engineer
CE Soultions
10 Shoshone Drive
Carmel, Indiana 46032
317-818-1912
Structural Engineer
Dimond Engineering
732 North Capitol Avenue
Indianapolis, Indiana 46204
317-634-4672
Mechanical / Eleictrical / Plumbing Engineer
Context Design
12 South Main Street, Suite 200
Fortville, Indiana 46040
317-485-6900
Landscape
Design 27 Technology & Acoustics
5366 Winthrop Avenue
Indianapolis, Indiana 46220
317-485-8000
Technology
VOLUME 2
BID PACKAGE No. 2
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
PRELIMINARY
NOT FOR
CONSTRUCTION
8/
3
1
/
2
0
1
5
1
1
:
0
7
:
1
6
A
M
C:
\
U
s
e
r
s
\
T
A
l
l
e
n
\
D
o
c
u
m
e
n
t
s
\
4
5
2
2
-
0
0
7
_
L
i
b
e
r
t
y
F
u
n
d
-
C
E
N
T
R
A
L
_
T
O
N
Y
_
L
O
CA
L
_
0
7
2
9
2
0
1
5
.
r
v
t
A000B
LI
B
E
R
T
Y
F
U
N
D
H
E
A
D
Q
U
A
R
T
E
R
S
CA
R
M
E
L
,
I
N
D
I
A
N
A
BP2 INDEX
4522-0007
08/28/15
Author
Checker
LIBERTY FUND HEADQUARTERS
LIBERTY FUND
NO.DESCRIPTIONDATE
SHEET INDEX - VOLUME 2
SHEET
#SHEET NAME
REV
DATE
E100SITE PLAN - ELECTRICAL
E200CLOWER L EVEL - AREA C - LIGHTING
E201AFIRST FLOOR - AREA A - LIGHTING
E201BFIRST FLOOR - AREA B - LIGHTING
E201CFIRST FLOOR - AREA C - LIGHTIN
E201DFIRST FLOOR - AREA D - LIGHTING
E202BSECOND FLOOR - AREA B - LIGHTING
E202CSECOND FLOOR - AREA C - LIGHTING
E210CLOWER LEVEL - AREA C - POWER
E211BFIRST FLOOR - AREA B - POWER
E211CFIRST FLOOR - AREA C - POWER
E211DFIRST FLOOR - AREA D - POWER
E212BSECOND FLOOR - AREA B - POWER
E212CSECOND FLOOR - AREA C - POWER
E220CLOWER L EVEL - AREA C - FIRE ALARM
E221AFIRST FLOOR - AREA A - FIRE ALARM
E221BFIRST FLOOR - AREA B - FIRE ALARM
E221CFIRST FLOOR - AREA C - FIRE ALARM
E221DFIRST FLOOR - AREA D - FIRE ALARM
E222BSECOND FLOOR - AREA B - FIRE ALARM
E222CSECOND FLOOR - AREA C - FIRE ALARM
E301MECHANICAL ROOM - ELECTRICAL
E401DETAILS - ELECTRICAL
E501SINGLE-LINE DIAGRAM
E601SCHEDULES - ELECTRICAL
E211AFIRST FLOOR - AREA A - POWER
SHEET INDEX - VOLUME 2
SHEET
#SHEET NAME
REV
DATE
GENERAL
002COVER SHEET - VOLUME 2
A000BBP2 INDEX
MECHANICAL
MP001SYMBOLS AND ABBREVIATIONS
M200CLOWER LEVEL - AREA C - MECHANICAL
M201AFIRST FLOOR - AREA A - MECHANICAL
M201BFIRST FLOOR - AREA B - MECHANICAL
M201CFIRST FLOOR - AREA C - MECHANICAL
M201DFIRST FLOOR - AREA D - MECHANICAL
M202BSECOND FLOOR - AREA B - MECHANICAL
M202CSECOND FLOOR - AREA C - MECHANICAL
M210CLOWER LEVEL - AREA C - MECHANICAL
M211AFIRST FLOOR - AREA A - MECHANICAL PIPING
M211BFIRST FLOOR - AREA B - MECHANICAL PIPING
M211CFIRST FLOOR - AREA C - MECHANICAL PIPING
M211DFIRST FLOOR - AREA D - MECHANICAL PIPING
M212BSECOND FLOOR - AREA B - MECHANICAL PIPING
M212CSECOND FLOOR - AREA C - MECHANICAL PIPING
M301ENLARGED MECH. ROOMS B134 & B218 - MECHANICAL
M302ENLARGED MECHANICAL ROOM C013 - MECHANICAL
M303ENLARGED MECHANCIAL ROOM D104 - MECHANICAL
M311ENLARGED MECH. ROOMS B134 & B218 - MECHANICAL PIPING
M312ENLARGED MECHANICAL ROOM C013 - MECHANICAL PIPING
M313ENLARGED MECHANICAL ROOM D104 - MECHANICAL PIPING
M401DETAILS - AIR DISTRIBUTION
M411DETAILS - LIQUID TRANSFER
M511
M601SCHEDULES - AIR DISTRIBUTION
M611SCHEDULES - LIQUID HEAT TRANSFER
M701CONTROL SCHEMATICS
M702CONTROL SCHEMATICS
PLUMBING
P200AFOUNDATION - AREA A - PLUMBING
P200BFOUNDATIONA - AREA B - PLUMBING
P200CFOUNDATION - AREA C - PLUMBING
P200C-1LOWER LEVEL - AREA C - PLUMBING
P200DFOUNDATION - AREA D - PLUMBING
P201AFIRST FLOOR - AREA A - PLUMBING
P201BFIRST FLOOR - AREA B - PLUMBING
P201CFIRST FLOOR - AREA C - PLUMBING
P201DFIRST FLOOR - AREA D - PLUMBING
P202BSECOND FLOOR - AREA B - PLUMBING
P202CSECOND FLOOR - AREA C - PLUMBING
P210OVERALL ROOF PLAN - PLUMBING
P302ENLARGED MECHANICAL ROOM C013 - PLUMBING
P303ENLARGED MECHANICAL ROOM D104 - PLUMBING
P601SCHEDULES - PLUMBING
FIRE PROTECTION
FP200CLOWER LEVEL - AREA C - FIRE PROTECTION
FP201AFIRST FLOOR - AREA A - FIRE PROTECTION
FP201CFIRST FLOOR - AREA C - FIRE PROTECTION
FP201BFIRST FLOOR - AREA B - FIRE PROTECTION
FP201DFIRST FLOOR - AREA D - FIRE PROTECTION
FP202BSECOND FLOOR - AREA B - FIRE PROTECTION
FP202CSECOND FLOOR - AREA C - FIRE PROTECTION
ELECTRICAL
E001SYMBOLS & ABBREVIATIONS - ELECTRICAL
TECHNOLOGY
T100 GENERAL NOTES AND LEGENDS
T001 BASEMENT DISTRIBUTION PLAN
T002 FIRST FLOOR - DISTRIBUTION PLAN
T003 SECOND FLOOR - DISTRIBUTION PLAN
T100 OVERALL BASEMENT
T101 FIRST FLOOR - AREA A
T102 FIRST FLOOR - AREA B
T103 FIRST FLOOR - AREA C
T104 FIRST FLOOR - AREA D
T105 SECOND FLOOR - AREA A
T106 SECOND FLOOR - AREA B
T107 SECOND FLOOR - AREA C
T200 ENLARGED TECHNOLOGY ROOMS
T300 TELECOM RISER AND GROUNDING DIAGRAMS
T400 AV SCHEMATIC DIAGRAMS
T401 AV SCHEMATIC DIAGRAMS
T410 SECURITY AND ACCESS CONTROL SCHEMATIC DIAGRAMS
T500 TELECOM DETAILS
T501 AV DETAILS
T502 AV DETAILS
T503 AV DETAILS
T504 AV DETAILS
T510 SECURITY AND ACCESS CONTROL DETAILS
CHARGING VALVE
SIGHT GLASS
FILTER-DRYER
BARE PIPE IN COVER
RADIATION COVER ONLY
FINNED TUBE RADIATION
FINNED TUBE RADIATION IN COVER
THERMOSTATIC EXPANSION VALVE
EVAPORATOR PRESSURE REGULATOR
MANUAL REFRIGERATION VALVE
STRAINER
FLANGED CONNECTION SIAMESE HOSE CONNECTION
PIPE ANCHOR
EXPANSION JOINT
PIPE ALIGNMENT GUIDES
UNION
END CAP
CONCENTRIC REDUCER
TEE DOWN
TEE UP
ELBOW DOWN
ELBOW UP
TEMPERATURE SENSOR
HUMIDISTAT
DUCT THERMOSTAT (ELECTRIC)
ROOM THERMOSTAT (HEAT/COOL)
ROOM THERMOSTAT (COOL)
DUCT THERMOSTAT (PNEUMATIC)
FLOW METER
MOTORIZED DAMPER
DIFFERENTIAL PRESSURE TRANSMITTER
ROOM THERMOSTAT (HEAT)
SAFETY/PRESSURE RELIEF VALVE
FLOW CONTROL VALVE
MAKEUP WATER VALVE
PRESSURE REDUCING VALVE
CHECK VALVE
BALANCING VALVE
VERTICAL SHUT-OFF/NEEDLE VALVE
SHUT-OFF VALVE
SHOCK ABSORBER
AIR CHAMBER
(DOWN IN ARROW DIRECTION)
PIPE PITCH ARROW
PRESSURE GAUGE
AUTOMATIC AIR VENT
COMPOUND GAUGE
FLEX CONNECTOR
CONDENSER WATER RETURN
GROUND LOOP WATER RETURN
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION
REFRIGERANT LIQUID
CONDENSER WATER SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
GROUND LOOP WATER SUPPLY
AUTOMATIC AIR VENT
PENDANT SPRINKLER HEAD
UPRIGHT SPRINKLER HEAD
FIRE PROTECTION PIPING
POST INDICATOR VALVE
FIRE HYDRANT
OXYGEN
VACUUM LINE
ACID WASTE (SUSPENDED)
ACID WASTE (BURIED)
DISTILLED WATER
ACID VENT
DEIONIZED WATER
FUEL OIL RETURN
FUEL OIL SUPPLY
INVERTED BUCKET TRAP
FLOAT & THERMOSTATIC TRAP
HEATING WATER RETURN
HEATING WATER SUPPLY
LOW PRESSURE CONDENSATE RETURN
LOW PRESSURE STEAM
RETURN OR EXHAUST DUCT DOWN
RETURN OR EXHAUST DUCT UP
FIRE DAMPER (FD) IN DUCT
SUPPLY DUCT DOWN
VOLUME DAMPER
SUPPLY DUCT UP
FUEL OIL VENT
NITROGEN
NITROUS OXIDE
FLOW ARROW
TEMP/PRESSURE RELIEF VALVE
CONCEALED SPRINKLER HEAD
DRY STANDPIPE
DRY PIPE SPRINKLER PIPING
PRE-ACTION SPRINKLER PIPING
ELBOW
TEE
CLEANOUT
FLOOR DRAIN
STORM WATER (SUSPENDED)
TEMPERED WATER
GAS
DRAIN LINE
SANITARY WASTE (SUSPENDED)
SANITARY WASTE (BURIED)
SANITARY VENT LINE
STORM WATER (BURIED)
COLD SOFT WATER
HOT WATER (180° F)
HOT WATER RETURN (140° F)
HOT WATER (140° F)
HOT WATER RETURN
HOT WATER
140°
GAS METER
WATER METER
TAMPER SWITCH
FLOW SWITCH
OXYGEN OUTLET
MEDICAL AIR OUTLET
NITROGEN OUTLET
NITROUS OXIDE OUTLET
VACUUM OUTLET
SLIDE
MEDICAL AIR
PIPE SLEEVE
HOT SOFT WATER
HOT SOFT WATER RETURN
CONTROL VALVE (TCV)
3-WAY CONTROL VALVE
WET FIRE PROTECTION PIPING
ALARM CHECK VALVE
REFRIGERANT HOT GAS
HOT WATER RETURN (180° F)
MEDIUM PRESSURE STEAM
HIGH PRESSURE STEAM
MEDIUM PRESSURE CONDENSATE RETURN
HIGH PRESSURE CONDENSATE RETURN
THERMOSTATIC TRAP
THROTTLING VALVE
PETE'S PLUG
FD
CARBON DIOXIDE SENSOR
VARIABLE FREQUENCY DRIVE
TEMPERATURE CONTROL PANEL
ACCESS PANEL
BOILER FEED WATER
EMERGENCY BOILER FEED WATER
COLD WATER
140°
180°
180°
T
CSW
HSW
HSWR
NON-POTABLE WATERNPW
G
AIR (WITH PSI)A
D
GM
WM
RPBP
RPZ
(REDUCED PRESSURE
BACKFLOW PREVENTER)
CS
CR
CHWS
CHWR
GS
GR
{
HS
HR
FOS
FOR
FOV
RD
RS
RL
RHG
DUAL TEMPERATURE SUPPLYDTS
DUAL TEMPERATURE RETURNDTR
BFW
EBFW
LPS
MPS
HPS
LPR
MPR
HPR
CONDENSATE PUMP DISCHARGEPD
CONDENSATE RETURNCR
F&T
IB
T
ECCENTRICAL REDUCER
CO
FD
FCV
D
GAS OUTLETG
MA
O
N
NO
V
S
MA
N
O
NO
V
DW
AV
DI
F
DS
DP
PA
WP
PIV
TS
FS
COMBINATION FIRE/SMOKE DAMPER
(FSD) IN DUCT
FSD
SD
SMOKE DAMPER (SD) IN DUCT
AP
INTERNAL LINED DUCT
CO2
FLOW SWITCH
FS
FM
DPT
M
VFD
TCP
WELL WATERWW
8"E.
DENOTED
EXISTING
WORK
CONNECTION
TO EXISTING
SECTION OR ELEVATION
NUMBER
THERMOMETER
T
C
S
T
H
T
H,C
T
C
T
T
E
H
T
DENOTED
NEW WORK
SIZE OF
PIPE OR
DUCT
DENOTED
EXISTING
SHEET NUMBER OF
SECTION OR ELEVATION
DETAIL (LETTER)
SHEET NUMBER OF
DETAIL LOCATION
ADAREA DRAIN
AFCAUTOMATIC FLOW CONTROL
AFFABOVE FINISHED FLOOR
AHRAIR HOSE REEL
AHUAIR HANDLING UNIT
ALTALTERNATE
APACCESS PANEL
ASAIR SEPARATOR
BDBLOWDOWN
BDDBACKDRAFT/PRESSURE RELIEF DAMPER
BTUBRITISH THERMAL UNIT
BVBALANCE VALVE
CBCATCH BASIN
CICAST IRON
CLCENTERLINE
COCLEANOUT
CONDCONDENSATE
CONVHYDRONIC CONVECTOR
CUHCABINET UNIT HEATER
CWCOLD WATER
DBDRY BULB
DFDRINKING FOUNTAIN
DIADIAMETER
DIFFDIFFUSER
DSDOWNSPOUT
DXCDIRECT EXPANSION COOLING COIL
EAEXHAUST AIR
EATENTERING AIR TEMPERATURE
EBBRELECTRIC BASEBOARD RADIATION
ECELECTRICAL CONCTRACTOR
EGEXHAUST GRILLE
ECONVELECTRIC CONVECTOR
ECUHELECTRIC CABINET UNIT HEATER
EFEXHAUST FAN
ELECELECTRICAL
ELEVELEVATION
EOMEND OF MAIN DRIP
EPUHELECTRIC PROPELLER UNIT HEATER
EREXHAUST REGISTER
ERCPELECTRIC RADIANT CEILING PANEL
ESPEXTERNAL STATIC PRESSURE
EWCELECTRIC WATER COOLER
EWHELECTRIC WATER HEATER
ETEXPANSION TANK
EEXISTING
FDFLOOR DRAIN OR FIRE DAMPER
FPVAVFAN POWERED VAV
FOBFLAT ON BOTTOM
FSDCOMBINATION FIRE/SMOKE DAMPER
FTRHYDRONIC FINNED TUBE RADIATION
GCGENERAL CONTRACTOR
GENGENERAL
HBHOSE BIBB
HTGHEATING
HWHOT WATER
IDINTERNAL DIAMETER
INV. EL.INVERTED ELEVATION
LATLEAVING AIR TEMPERATURE
LAVLAVATORY
MBH1000 BTU/HOUR
MECHMECHANICAL
MHMANHOLE
MCMECHANICAL CONTRACTOR
MSMOP SINK
MUVAUTOMATIC MAKE-UP VALVE
NCNORMALLY CLOSED
NONORMALLY OPEN
OAOUTSIDE AIR
OBDOPPOSED BLADE DAMPER
ODOUTSIDE DIAMETER
OFDOVERFLOW DRAIN
OSDOPEN SITE DRAIN
PFHXPLATE AND FRAME HEAT EXCHANGER
PIVPOST INDICATOR VALVE
PLBGPLUMBING
PRVPRESSURE REDUCING VALVE
PUHPROPELLER UNIT HEATER
RARETURN AIR
RCPRADIANT CIELING HEATING PANEL
RCNPREINFORCED CONCRETE PIPE
RDROOF DRAIN
RECIRCRECIRCULATING
RGRETURN GRILLE
RPZREDUCED PRESSURE BACKFLOW PREVENTER
RRRETURN REGISTER
RIVROOF INTAKE VENT
RRVROOF RELIEF VENT
SASUPPLY AIR
SANSANITARY
SDSMOKE DAMPER
SGSUPPLY GRILLE
SHDRSHOWER DRAIN
SKSINK
SRSUPPLY REGISTER
SSSTAINLESS STEEL
STHXSHELL AND TUBE HEAT EXCHANGER
TCCTEMPERATURE CONTROL CONTRACTOR
TCPTEMPERATURE CONTROL PANEL
TGTRANSFER GRILLE
TOTRANSFER OPENING
TPTRAP PRIMER LINE
TYPTYPICAL
URURINAL
VAVVARIABLE AIR VOLUME
VCPVETRIFIED CLAY PIPE
VFDVARIABLE FREQUENCY DRIVE
VSVENT STACK
VTRVENT THROUGH ROOF
WWASTE
WBWET BULB
WCWATER CLOSET
WHWALL HYDRANT
WSWASTE STACK
ABBREVIATIONSTEMPERATURE CONTROL/MONITORING
DRAWING NOTATIONS
SECTIONS AND DETAILS
RADIATION SYMBOLS
DUCT SYMBOLS
FIRE PROTECTION SYSTEM
MEDICAL
STEAM PIPING
HVAC PIPING
VALVES
REFRIGERATION VALVES/FITTINGS
PLUMBING
PIPE FITTINGS
ALL NEW WORK IS DRAWN DARK.
THESE NOTES APPLY TO EACH AND EVERY "M" AND "P" SERIES DRAWING.
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK WITH ALL OTHER TRADES.
SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS RELATED TO COORDINATION.
COLORS OF EXPOSED UNITS SHALL BE SELECTED BY ARCHITECT. COLORS SHALL BE
MANUFACTURER'S STANDARD OR CUSTOM COLOR AS REQUESTED.
PROVIDE SLEEVES FOR ALL PIPING AND DUCTWORK THAT PENETRATES FULL HEIGHT WALLS,
WHETHER SHOWN OR NOT.
SEE SPECIFICATIONS. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING
ARE NOTED ON THOSE DRAWINGS. ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE M600 &
P600 SERIES DRAWINGS FOR SCHEDULES.
SEE 'S' SERIES DRAWINGS FOR TYPICAL LINTEL INSTALLATION.
CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING, FLUSHING AND FILLING OF PIPING AND
SYSTEMS AS REQUIRED.
M.C. WILL BE RESPONSIBLE FOR CHEMICAL TREATMENT OF SYSTEMS.
THERMOSTATS SHOWN ON EQUIPMENT SHALL BE INSTALLED WITH SENSOR TO SENSE RETURN
AIR TEMPERATURE. MOUNT THERMOSTATS WITH BOTTOM AT 48" A.F.F. UNLESS NOTED
OTHERWISE. ALL THERMOSTAT LOCATIONS SHALL BE REVIEWED BY ARCHITECT IN FIELD
PRIOR
TO INSTALLATION.
THERMOSTATS IN PRIVATE OFFICES SHALL BE ADJUSTABLE TYPE. THERMOSTATS IN COMMON
AREAS SHALL BE SENSORS WITH ADJUSTMENT IN REMOTE LOCATION AS REQUIRED BY
OWNER.
ACCESS PANELS ARE REQUIRED IN HARD CEILINGS WHETHER SHOWN OR NOT, WHEREVER
ACCESS IS REQUIRED TO INSTALL OR SERVICE MECHANICAL EQUIPMENT. SEE 'A' SERIES
DRAWINGS AND SPECIFICATIONS. COORDINATE LOCATION WITH REFLECTED CEILING
PLAN.
CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING AND CUTTING HOLES THRU
WALLS AND FLOORS AS REQUIRED TO INSTALL NEW PIPING AND DUCTWORK, WHETHER
SHOWN OR NOT.
ALL WIRING TO THERMOSTATS SHALL BE ROUTED CONCEALED. WIREMOLD IS NOT
ACCEPTABLE.
AN ENGRAVED PLASTIC LAMINATE TAG SHALL BE ADHERED TO THE ACOUSTICAL LAY-IN
CEILING GRID AT THE LOCATION WHERE ALL TERMINAL DEVICES, VALVES, FANS, ETC. ARE
ABOVE THAT CEILING INDICATING THE EQUIPMENT NOMENCLATURE INSTALLED.
ROUTE BRANCH CHWS & CHWR, HS & HR PIPING TO EQUIPMENT (MINIMUM 1" UNLESS
NOTED AS LARGER) WITH A HYDRONIC COIL WHETHER SHOWN OR NOT. ALL COOLING
COILS SHALL HAVE MINIMUM 3/4" CONDENSATE PIPE UNLESS NOTED OTHERWISE.
TYPICAL PIPING DETAILS SHALL APPLY. FLEX DUCT CONNECTIONS TO DIFFUSERS SHALL BE A
MAXIMUM OF 36" IN LENGTH UNLESS SHOWN OTHERWISE.
BRANCH DUCTS SHALL BE 45° BOOT TAP FROM SIDE OF MAIN. NO SPIN-IN FITTINGS.
PROVIDE VOLUME DAMPERS IN ALL BRANCH DUCTS TO DIFFUSERS, EXHAUST GRILLES, ETC.
WHETHER SHOWN OR NOT. THESE DAMPERS ARE TO BE USED FOR SYSTEM BALANCE.
DAMPERS IN DIFFUSERS, REGISTERS, ETC. SHALL NOT BE USED FOR AIR BALANCE UNLESS
APPROVED BY ENGINEER.
FOR ALL AIR OUTLETS INSTALLED IN HARD CEILINGS, VOLUME DAMPERS SHALL BE LOCATED
ABOVE ACCESSIBLE CEILING IN ADJACENT SPACE IF POSSIBLE, IF NOT POSSIBLE THEN
LOCATE SO THEY CAN BE ADJUSTED THROUGH THE FACE OF THE AIR OUTLET OR PROVIDE
ACCESS PANEL IN CEILING UNLESS NOTED OTHERWISE. SEE REFLECTED CEILING PLAN TO
COORDINATE LOCATION OF AIR OUTLETS.
COORDINATE COIL CONNECTIONS FOR ALL EQUIPMENT WITH MFG. PRIOR TO ORDERING.
REFERENCE M400's FOR TYPICAL AND SPECIFIC INSTALLATION REQUIREMENTS FOR
EQUIPMENT, ETC.
SUPPLY DIFFUSERS TO BE INSTALLED NO CLOSER THAN 5'-0" TO ALL SMOKE DETECTORS. REFER
TO T-SERIES DRAWINGS AND E-SERIES DRAWINGS FOR ADDITIONAL CEILING INSTALLED
DEVICES.
COORDINATE AND ADJUST DIFFUSER LOCATIONS, AS NEEDED.
CONTRACTOR SHALL PROVIDE ALL REQUIRED GAS VENT PIPING WHETHER SHOWN OR NOT.
ALL VENT LINES SHALL TERMINATE OUTSIDE OF BUILDING AT 24" ABOVE PARAPET WITH
MUSHROOM CAP & INSECT SCREEN.
GAS VENT PIPING SHALL BE BLACK IRON.
MECHANICAL CONTRACTOR SHALL BLANK-OFF UNUSED PORTIONS OF ALL LOUVERS
WHETHER SHOWN OR NOT WITH SHEETMETAL AND 2" OF RIGID INSULATION.
WORKMANSHIP FOR ALL DUCTWORK AND EQUIPMENT MUST BE IN COMPLIANCE WITH
SMACNA STANDARDS.
LOCATE AIR TERMINAL BOXES, VALVES, METERS, GAUGES, DAMPERS, FANS, ETC., ABOVE
LAY-IN CEILING OR IN EXPOSED AREAS, IF POSSIBLE.
ALL VALVES MUST BE ACCESSIBLE. DO NOT HIDE DEVICES BEHIND WALLS OR PLASTER
CEILINGS OR BAR JOISTS. WHERE UNITS MUST BE INSTALLED ABOVE HARD CEILINGS,
CONTROL RELAYS OR SIMILAR ACCESSORIES MUST BE LOCATED FOR MAINTENANCE
THROUGH THE ACCESS PANEL.
SHEETMETAL CONTRACTOR TO PROVIDE DUCT ACCESS FOR FIRE DAMPERS, MOTORIZED
DAMPERS, AIR FLOW MEASURING STATIONS, AND ON THE INLET SIDE OF THE REHEAT COILS.
COORDINATE WITH MECHANICAL CONTRACTOR AND GENERAL TRADES CONTRACTOR.
ALL CEILING HVAC EQUIPMENT WITH A COOLING COIL MUST BE EQUIPPED WITH A
SECONDARY DRAIN PAN AND PROPER INDEPENDENT DRAINAGE SYSTEM.
DO NOT RUN ANY PIPING, DUCTWORK, OR EQUIPMENT ABOVE THE DATA ROOMS UNLESS
APPROVED BY ENGINEER..
ALL FLOOR OR OUTDOOR MOUNTED EQUIPMENT SHALL BE INSTALLED ON A 4" CONCRETE
HOUSEKEEPING PAD. CONCRETE PADS FOR ALL HVAC EQUIPMENT MUST BE A FACTORY MIX
(NOT BAG MIXED ON SITE).
NO PULLED PIPING TEES. USE MANUFACTURED TEES.
ALL INTERIOR CONDENSATE DRAINS SHALL TERMINATE WITH 90° ELBOW DIRECTLY OVER
DRAIN.
TEMPERATURE CONTROL CONTRACTOR SHALL NOTIFY AND COORDINATE MECHANICAL
CONTRACTOR OF ALL WELLS NEEDED IN PIPING.
ALL SUPPLY AIR AND RETURN AIR GRILLES IN HARD CEILINGS OR WALLS SHALL HAVE CLEAR
ANODIZED FINISH.
MECHANICAL GENERAL NOTES
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
Date:Issue:
08/28/15 BID PACKAGE #2
KEYPLAN
A B
C
D
8/
2
8
/
2
0
1
5
5
:
1
1
:
0
5
P
M
C:
\
U
s
e
r
s
\
v
h
o
b
b
s
\
D
o
c
u
m
e
n
t
s
\
1
4
0
4
3
-
L
I
B
E
R
T
Y
F
U
N
D
H
Q
M
E
P
_
v
h
o
b
b
s
.
r
v
t
MP001
LI
B
E
R
T
Y
F
U
N
D
H
E
A
D
Q
U
A
R
T
E
R
S
CA
R
M
E
L
,
I
N
D
I
A
N
A
08/28/2015 BID PACKAGE #2
SYMBOLS AND
ABBREVIATIONS
14043
08/28/15
MJE
MJE
MEP Engineers DA#14043
R.E. Dimond and Associates, Inc.
732 North Capitol Avenue
Indianapolis, Indiana 46204
317.634.4672
LIBERTY FUND HEADQUARTERS
Owner
IT
W
O
R
K
R
O
O
M
C0
1
0
ST
O
R
A
G
E
C0
1
1
EL
E
V
E
Q
U
I
P
C0
0
2
CO
R
R
I
D
O
R
C0
0
4
IT
S
T
O
R
A
G
E
C0
0
7
MD
F
C0
0
8
ST
A
I
R
C0
0
5
ST
O
R
A
G
E
C0
0
3
ST
A
I
R
C0
1
4
22
"
/
1
4
"
22
"
/
1
4
"
36"/12"
M3
0
2
C0
1
2
40
"
/
1
0
"
40
"
/
1
4
"
40
"
/
2
0
"
40
"
/
1
0
"
40
"
/
1
4
"
48"/16"
36"/12"
48
/
1
6
L
I
N
E
D
R
.
A
.
D
U
C
T
U
P
T
O
L
I
B
R
A
R
Y
ME
Z
Z
A
N
I
N
E
L
E
V
E
L
W
I
T
H
F
I
R
E
D
A
M
P
E
R
RA
T
E
D
E
N
C
L
O
S
U
R
E
P
E
N
E
T
R
A
T
I
O
N
.
I
N
S
T
A
L
L
HI
N
G
E
D
A
C
C
E
S
S
P
A
N
E
L
.
S
E
E
M
2
0
1
C
.
12"/10"
10
"
/
1
0
"
18"/14"
12"/12"
20"/10"
48
x
1
6
L
I
N
E
D
R
.
A
.
D
U
C
T
U
P
TO
L
I
B
R
A
R
Y
M
E
Z
Z
A
N
I
N
E
LE
V
E
L
W
I
T
H
F
I
R
E
D
A
M
P
E
R
AT
R
A
T
E
D
E
N
C
L
O
S
U
R
E
PE
N
E
T
R
A
T
I
O
N
.
I
N
S
T
A
L
L
HI
N
G
E
D
A
C
C
E
S
S
P
A
N
E
L
.
SE
E
M
2
0
1
C
.
10
/
1
0
V
E
N
T
I
L
A
T
I
O
N
D
U
C
T
UP
T
O
F
I
R
S
T
F
L
O
O
R
L
E
V
E
L
.
SE
E
M
2
0
1
C
.
30
0
30
0
24
"
/
1
2
"
S
G
20
0
12
5
12
"
/
1
2
"
S
G
22
5
EL
E
C
T
R
I
C
A
L
R
O
O
M
C0
0
1
A
36"/12"
36
"
/
1
2
"
8"
/
8
"
S
G
10
0
8"
/
8
"
R
G
8"
/
8
"
R
G
24
"
/
8
"
T
G
26"/12"
26
"
/
1
2
"
2
0
"
/
1
2
"
2
0
"
/
1
2
"
8"
8"
8"
8"
8 "
8 "
8 "
8 "
30
0
30
0
30
0
30
0
30
0
30
0
30
0
30
0
30
0
30
0
8"
8"
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
10
"
10
"
22"/12"
1
2
"
/
1
2
"
12
"
/
1
2
"
T
G
1
1
24
"
/
1
2
"
R
G
12
"
/
1
2
"
S
G
40
0
WS
H
P
-
N
-
A
1
0
9
40
"
/
2
0
"
2
2
24
"
/
2
4
"
15
0
12
"
/
1
2
"
15
0
15
0
WS
H
P
-
N
-
A
1
0
7
WS
H
P
-
N
-
C
1
0
8
WS
H
P
-
L
-
C
0
0
1
A
WS
H
P
-
L
-
C
0
0
4
CA CE
C7
.
9
C5
.
1
C5
.
9
C3
.
1
CDCB
C6
C5
C4
C3
C7
C8
DA DB
CJCH
CF
C2
C9
CC
C2
.
5
C8
.
5
C7
.
5
C3
.
5
12
"
/
1
2
"
2 0 "/1 0 "
2
0
"
/
1
0
"
12"/12"
20"/10"
12"/8"
12"/12"
8"
8 "/8 "
3
8
"
/
6
"
8
"
/
6
"
8"/6"
3
4
4
4
4
12
/
1
0
T
O
S
.
G
.
LO
W
E
R
L
I
B
R
A
R
Y
C0
0
1
14
"
/
1
0
"
5
5
48
"
/
1
6
"
24
"
/
1
2
"
R
G
EF
-
C
0
0
8
8"
20"/14"
4
4
4
6 6
6
6
6
EF
-
C
0
0
2
8"
/
8
"
5
36
"
/
8
"
J M4
0
1
J M4
0
1
J M4
0
1
J M401
J M4
0
1
TY
P
.
PLAN NOTES:#PLAN NOTES:1.INSTALL FIRE DAMPER WITH ACCESS AT DUCT PENETRATION THROUGH RATED WALL ASSEMBLY.2.PROVIDE FIRE DAMPER WITH ACCESS PANEL IN DUCTWORK AT FLOOR PENETRATIONS TO LEVEL ABOVE. MANUAL VOLUME DAMPER IN BRANCH DUCT TAKE-OFF FROM MAIN.3.CONNECT VENTILATION AIR DUCTWORK TO RETURN AIR DUCTWORK. BALANCE TO 75 CFM.4.TRANSITION AND CONNECT DUCTWORK TO LINEAR BAR GRILLE ABOVE. COORDINATE EXACT LOCATION WITH STRUCTURE.5.DUCTED TRANSFER OPENING ABOVE CEILING.6.DUCTWORK TO BE INTERNALLY LINED WITH 1" ACOUSTICAL DUCT LINER.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD
8/28/2015 6:14:11 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt
M200CLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 LOWER LEVEL - AREA C - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner
NO
R
T
H
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
LO
W
E
R
L
E
V
E
L
-
A
R
E
A
C
-
M
E
C
H
A
N
I
C
A
L
DN
VE
S
T
I
B
U
L
E
A1
0
0
ME
N
A1
1
2
WO
M
E
N
A1
1
3
CL
O
S
E
T
A1
0
3
OF
F
I
C
E
A1
0
4
ST
O
R
A
G
E
A1
0
2
PI
C
K
-
U
P
/
S
T
O
R
A
G
E
A1
1
4
EB
B
R
-
A
EW
H
-
A
1
EB
B
R
-
A
42
0
30
0
10
0
44
0
72
"
/
2
4
"
R
G
18
5
0
72
"
/
2
4
"
R
G
18
5
0
EB
B
R
-
A
EB
B
R
-
A
48
"
/
4
"
R
G
64
0
48
"
/
4
"
S
G
64
0
1
1
EB
B
R
-
A
EB
B
R
-
A
1
1
4
4
EB
B
R
-
A
EB
B
R
-
A
EB
B
R
-
A
1
1
1
EB
B
R
-
A
EB
B
R
-
A
EB
B
R
-
A
1
1
1
1
3
3
2
5
CO
R
R
I
D
O
R
A1
0
8
CO
R
R
I
D
O
R
A1
1
0
CO
R
R
I
D
O
R
A1
0
6
EN
T
R
Y
A1
0
1
CO
R
R
I
D
O
R
A1
0
5
CO
N
F
E
R
E
N
C
E
A1
0
7
CO
N
F
E
R
E
N
C
E
A1
0
9
2
48
"
/
4
"
S
G
64
0
48
"
/
4
"
R
G
64
0
2
2
72
"
/
6
"
S
G
40
0
72
"
/
6
"
S
G
40
0
WS
H
P
-
O
-
A
1
0
4
1
4
"
/
1
2
"
1 2 "
10
0
10
0
8"
12"/12"
WS
H
P
-
N
-
A
1
1
4
6
"
12
"
WS
H
P
-
U
-
A
1
0
6
WS
H
P
-
U
-
A
1
0
1
8"
6"
6"
A3
AH
A5
A1
AA
AE
AB
AF
A2
A4
AC
AG
AC
.
6
AG.6AE.5
5
EB
B
R
-
A
EB
B
R
-
A
1
1
1
9'
-
0
"
9'
-
0
"
9'
-
0
"
15
'
-
0
"
15
'
-
0
"
15
'
-
0
"
15
'
-
0
"
18
'
-
0
"
18
'
-
0
"
14
'
-
0
"
14
'
-
0
"
14
'
-
0
"
14
'
-
0
"
9'
-
0
"
4
K
W
6
6
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
30
0
30
0
30
0
30
0
30
0
30
0
30
0
30
0
EF
-
A
1
1
3
EF
-
A
1
1
2
7
8
2
0
"
/
6
"
2 0 "/8 "
1
6
"
/
6
"
16"/6"
8"
20"/8"
20"/6"
8
"
2
0
"
/
8
"
2 4 "/1 4 "
1
6
"
/
6
"
1 6 "/6 "
16"/6"
16"/6"
24"/14"
J M4
0
1
J M4
0
1
4
10
PLAN NOTES:#PLAN NOTES:1.EBBR-A - DRAFT BARRIER AT BASE OF WINDOW. PEDESTAL MOUNTED. LIKE TPI-9300 DBT SERIES. 100 W/FT. CLEAR ANODIZED FINISH. 12 GA ENCLOSURE.INTEGRAL THERMOSTAT. 3-1/2" MAX DEPTH X 6" TALL. FINISHED BACK AND ENDCAPS. FIELD VERIFY EXACT ENCLOSURE LENGTHS REQUIRED.2.LINEAR SLOT DIFFUSER LIKE PRICE SDS50, 1 SLOT, 1/2" SLOT WIDTH, 48" LENGTH, 8"INLET, SDA PLENUM. TYPICAL.3.RETURN AIR GRILLE. CLEAR ANODIZED FINISH.4.HD LINEAR BAR GRILLE IN FLOOR LIKE PRICE LBPH OR EQUAL. CLEAR ANODIZED.5.ALL DUCTWORK INSTALLED IN THIS AREA MUST BE OPERATIONAL AND BALANCED PRIOR TO INSTALLATION OF CEILING SYSTEM. CLOSELY COORDINATE INSTALLATION OF DUCTWORK WITH ALL TRADES.6.REFER TO ARCHITECTURAL ELEVATIONS FOR GRILLE ELEVATION.7.PROVIDE 24"x24"x12" DEEP INSULATED PLENUM ON BACK OF LOUVER. CONNECT 10/10 E.A. DUCTS FROM EXHAUST FANS BELOW TO PLENUM. BLANK OFF UNUSED LOUVER WITH 2" RIGID INSULATION AND SHEET-METAL. SEAL WATER-TIGHT. REFER TO A-SERIES DWGS FOR LOUVER LOCATION.8.PROVIDE 24"x24"x12" DEEP INSULATED PLENUM ON BACK OF LOUVER. CONNECT BLANK OFF UNUSED LOUVER WITH 2" RIGID INSULATION AND SHEET-METAL. SEAL WATER-TIGHT. REFER TO A-SERIES DWGS FOR LOUVER LOCATION.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD
8/28/2015 6:58:58 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt
M201ALIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA A - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner
NO
R
T
H
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
FI
R
S
T
F
L
O
O
R
-
A
R
E
A
A
-
M
E
C
H
A
N
I
C
A
L
MA
C
H
I
N
E
B1
3
2
UN
A
S
S
I
G
N
E
D
B1
2
9
FE
L
L
O
W
B1
2
5
FE
L
L
O
W
B1
2
7
FE
L
L
O
W
B1
2
3
FE
L
L
O
W
B1
0
8
FE
L
L
O
W
B1
0
6
FE
L
L
O
W
B1
0
2
FE
L
L
O
W
B1
0
4
CH
A
I
R
M
A
N
B1
0
0
AS
S
I
S
T
A
N
T
B1
3
1
WO
M
E
N
B1
1
0
ME
N
B1
1
1
ME
C
H
A
N
I
C
A
L
B1
3
4
OF
F
I
C
E
B1
3
0
FE
L
L
O
W
B1
0
3
FE
L
L
O
W
B1
0
1
FE
L
L
O
W
B1
0
5
FE
L
L
O
W
B1
0
7
FE
L
L
O
W
B1
2
2
FE
L
L
O
W
B1
2
6
UN
A
S
S
I
G
N
E
D
B1
2
8
OF
F
I
C
E
B1
2
0
EN
C
L
A
V
E
B1
1
9
WE
L
L
N
E
S
S
RO
O
M
B1
1
3
ST
O
R
A
G
E
/
FU
T
U
R
E
A
S
T
.
B1
1
7
ST
O
R
A
G
E
B1
1
6
EL
E
C
T
B1
1
5
WO
R
K
A
R
E
A
B1
1
4
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
2
1
A
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
1
8
A
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
1
8
B
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
0
9
A
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
1
2
B
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
1
2
A
CO
R
R
I
D
O
R
B1
1
2
17
5
17
0
16
0
16
0
16
0
16
0
21
0
21
0
21
0
24
0
15
0
15
0
17
5
27
5
20
0
21
0
22
0
21
0
21
0
21
0
21
0
24
0
20
0
15
0
15
0
15
0
15
0
20
0
20
0
20
0
12
"
/
1
2
"
E
R
35
0
12
"
/
1
2
"
E
R
35
0
12
5
1 M3
0
1
2 M3
0
1
16"/12"
20"/10"
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
2
4
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
M3
0
1
B3
1
2
24
"
/
2
4
"
24"/8"
8"
24"/8"
32
5
18"/8"
20
0
20
0
CO
R
R
I
D
O
R
B1
0
9
CO
R
R
I
D
O
R
B1
2
1
24"/8"
24"/8"
16"/8"
14"/10"
24"/10"
8"
8"
8"
8"
10"
10"
10"
10"
10"
10"10"
10"
10"
10"
10"
10"
10"
10"
10"
10"
10"
16"/12"
10"
10"
8"
8"
20"/12"
20"/10"
8"
8"
16"/10"
16"/10"
10"
24
"
/
1
2
"
R
G
24
"
/
2
4
"
R
G
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
WS
H
P
-
N
-
B
1
0
1
WS
H
P
-
O
-
B
1
0
5
WS
H
P
-
M
-
B
1
2
2
WS
H
P
-
N
-
B
1
2
6
WS
H
P
-
O
-
B
1
2
9
WS
H
P
-
P
-
B
1
1
6
BB
BB
BB
BB
BB
BB
BB
AA
BB
AA
AA
AA
BB
BB
BB
BB
AA
AA
AA
AA
AA
AA
WS
H
P
-
L
-
B
1
1
9
75
75
WS
H
P
-
R
-
B
1
1
4
BA BB BC BD
B6
B3
B4
B5
B7
B4
.
3
B4
.
8
B1
B2
B1
.
6
B2
.
4
B5
.
7
BA.6 BC.4
18"/8"
8"
8"
24"/8"
20"/10"
1
14
'
-
0
"
EF
-
B
1
3
2
8"8"
WS
H
P
-
K
-
B
1
0
0
4
3
6
4
2
5
2
4
3
J M40
1
J M40
1
J M4
0
1
J M4
0
1
12
"
/
1
2
"
T
G
8"/
8
"
BB
BB
BB
BB
8"
8"
PLAN NOTES:#PLAN NOTES:1.FIRE DAMPER WITH ACCESS AT DUCTWORK PENETRATION.2.BALANCE BRANCH VENTILATION AIR DUCT TO 80 CFM.3.BALANCE BRANCH VENTILATION AIR DUCT TO 120 CFM.4.BALANCE BRANCH VENTILATION AIR DUCT TO 160 CFM.5.BALANCE BRANCH VENTILATION AIR DUCT TO 240 CFM.6.BALANCE BRANCH VENTILATION AIR DUCT TO 380 CFM.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.G2. ALL SUPPLY DUCTWORK FROM WSHP'S SHALL BE INTERNALLY LINED WITH 1"ACOUSTICAL DUCT LINER UP TO BRANCH DUCTWORK TAKE-OFFS.G3.PROVIDE LINED ACOUSTICAL DUCT ELBOW WITH FILTER PROVISION ON EACHAND EVERY HORIZONTAL HEAT PUMP.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD
8/28/2015 5:14:57 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt
M201BLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA B - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204317.634.4672LIBERTY FUND HEADQUARTERSOwner
NO
R
T
H
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
FI
R
S
T
F
L
O
O
R
-
A
R
E
A
B
-
M
E
C
H
A
N
I
C
A
L
DN
UN
I
S
E
X
RE
S
T
R
O
O
M
C1
0
9
EN
C
L
A
V
E
C1
0
7
LI
B
R
A
R
I
A
N
C1
0
4
LI
B
R
A
R
Y
S
U
P
P
O
R
T
C1
0
3
LI
B
R
A
R
Y
C1
0
0
AR
C
H
I
V
E
C1
0
6
20
0
90
27
5
1
M3
0
2
55
0
16
"
/
4
8
"
16
"
/
4
8
"
26
"
/
6
"
1
6
"
/
6
"
8"
/
6
"
1
4
"
/
1
0
"
1
4
"
/
1
0
"
30
0
30
0
S.
A
.
A
N
D
R
.
A
.
D
U
C
T
U
P
T
O
2
N
D
F
L
O
O
R
.
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
EB
B
R
-
A
EB
B
R
-
A
1
4
4
6
EB
B
R
-
A
EB
B
R
-
A
1
EB
B
R
-
A
1
EB
B
R
-
A
1
5
5
5
1 2 "
1
0
"
48
"
/
6
"
R
G
64
0
48
"
/
4
"
S
G
44
0
48
"
/
4
"
S
G
20
0
18
"
x
1
8
"
R
G
60
0
24
"
/
1
2
"
R
G
20
0
42
"
/
4
"
S
G
19
0
42
"
/
4
"
S
G
19
0
42
"
/
4
"
S
G
19
0
42
"
/
4
"
S
G
19
0
42
"
/
4
"
S
G
19
0
42
"
/
4
"
S
G
19
0
42
"
/
4
"
S
G
19
0
42
"
/
4
"
S
G
19
0
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
FT
R
-
A
AS
S
I
S
T
A
N
T
C1
1
0
OF
F
I
C
E
C1
1
1
EL
E
V
A
T
O
R
L
O
B
B
Y
C1
0
5
OF
F
I
C
E
C1
0
8
ST
A
I
R
C1
0
2
ST
A
I
R
C1
0
1
ST
O
R
A
G
E
C1
1
2
10"/10"
WS
H
P
-
N
-
C
1
1
1
6
"
WS
H
P
-
J
-
C
1
1
0
2
2
2
6
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
14
"
/
4
"
14
"
/
4
"
EF
-
C
1
0
9
7
8
6"
/
6
"
6"/6"
9
9
10
"
TY
P
.
10
"
TY
P
.
10
10
10
10
5
5
CA CE
C7
.
9
C5
.
1
C5
.
9
C3
.
1
B1
CDCB
C6
A3
C5
C4
C3
C7
C8
A5
CJCH
CF
CG
C1
C2
C9
CC
D5
A2
A4
C2
.
5
C8
.
5
CG
.
9
D4
.
3
D4
.
7
C7
.
5
C3
.
5
10
"
/
1
0
"
10
'
-
0
"
6'
-
6
"
13
'
-
0
"
7'
-
0
"
J M4
0
1
J M4
0
1
CA
CD
CB
CC
16
"
/
4
8
"
14
"
/
1
8
"
16
"
/
4
8
"
40
"
/
2
0
"
12
"
/
3
6
"
40
"
/
1
4
"
14
"
/
1
4
"
WS
H
P
-
G
-
C
0
0
1
30
"
/
1
6
"
12
"
/
1
0
"
12
"
/
3
6
"
8"
10
"
4"
/
4
2
"
10
"
4"
/
4
2
"
6"
/
4
8
"
6"
/
4
8
"
4"
/
4
8
"
4"
/
4
8
"
4"
/
4
8
"
4"
/
4
8
"
WS
H
P
-
H
-
C
1
0
0
A
PLAN NOTES:#PLAN NOTES:1.EBBR-A - DRAFT BARRIER AT BASE OF WINDOW. PEDESTAL MOUNTED. LIKE TPI-9300 DBT SERIES. 100 W/FT. CLEAR ANODIZED FINISH. 12 GA ENCLOSURE. INTEGRAL THERMOSTAT. 3-1/2" MAX DEPTH X 6" TALL. FINISHED BACK AND ENDCAPS. FIELD VERIFY EXACT ENCLOSURE LENGTHS REQUIRED.2.HD LINEAR BAR GRILLE IN FLOOR LIKE PRICE LBPH-25C SERIES. CLEAR ANODIZED FINISH.3.DOUBLE DEFLECTION SUPPLY AIR GRILLE WITH OPPOSED BLADE DAMPER.4.1" INTERNALLY LINED DUCT UP AND DOWN IN CHASE. COORDINATE STRUCTURAL OPENINGS IN FLOOR WITH S-SERIES DWGS.5.HYDRONIC FINNED TUBE RADIATION. REFER TO A-SERIES DWG'S FOR ENCLOSURE DETAIL.6.DUCTWORK TO BE INTERNALLY LINED WITH 1" ACOUSTICAL DUCT LINER.7.6" ROUND FROM EF UP TO ROOF AND TERMINATE WITH GOOSENECK.8.10/10 VENTILATION AIR DUCT UP AND DOWN IN CHASE. 10/10 S.A. DUCT AND 12/10 R.A. DUCT UP TO SECOND LEVEL. PROVIDE FIRE DAMPER WITH ACCESS PANEL AT ALL DUCT PENETRATIONS.9.BALANCE VENTILATION AIR DUCT SERVING WSHP TO 50 CFM.10.CONTINUOUS LINEAR SLOT DIFFUSER LIKE PRICE "AS" SERIES. 1-1" SLOT, WITH 2 ACTIVE LENGTH SECTIONS. PROVIDE INSULATED PLENUM WITH 10" INLET. PROVIDE BLANKOFFS FOR INACTIVE SECTIONS.11.ALL DUCTWORK INSTALLED IN THIS AREA MUST BE BALANCED AND OPERATIONAL PRIOR TO INSTALLATION OF CEILING SYSTEM.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD
8/28/2015 5:16:04 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt
M201CLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA C - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner
NO
R
T
H
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
FI
R
S
T
F
L
O
O
R
-
A
R
E
A
C
-
M
E
C
H
A
N
I
C
A
L
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
Li
b
r
a
r
y
S
e
c
t
i
o
n
1
DW
ICE
ME
N
S
D1
1
7
CO
R
R
I
D
O
R
D1
0
7
CO
R
R
I
D
O
R
D1
0
2
WO
M
E
N
D1
1
3
BR
E
A
K
O
U
T
D1
0
9
VE
S
T
I
B
U
L
E
D1
0
0
ST
A
F
F
B
R
E
A
K
A
R
E
A
D1
0
1
DI
N
I
N
G
D1
0
8
KI
T
C
H
E
N
D1
0
3
ST
O
R
A
G
E
D1
0
5
GO
O
D
R
I
C
H
R
O
O
M
D1
1
0
EX
E
R
C
I
S
E
D1
1
5
ME
C
H
A
N
I
C
A
L
D1
0
4
LO
C
K
E
R
S
D1
1
6
JA
N
I
T
O
R
I
A
L
D1
1
2
LO
C
K
E
R
D1
1
4
CO
R
R
I
D
O
R
D1
0
6
ST
O
R
A
G
E
D1
0
3
A
ST
O
R
A
G
E
D1
0
3
B
50
0
50
0
20
0
22
5
27
5
27
5
8"
/
8
"
E
R
10
0
8"
/
8
"
E
R
10
0
12
"
/
1
2
"
E
R
25
0
8"
/
8
"
E
R
75
12
"
/
1
2
"
E
R
25
0
2 4 "/1 6 "
2 2 "/1 6 "
2 2 "/1 6 "2 6 "/1 4 "
2
4
"
/
1
4
"
2
6
"
/
1
4
"
2
2
"
/
1
6
"
2
6
"
/
1
4
"
2
4
"
/
1
4
"
2
0
"
/
1
4
"
3
0
"
/
1
4
"
2
8
"
/
1
4
"
2
6
"
/
1
4
"
3 0 "/1 4 "
2
0
"
/
1
2
"
1 6 "/1 8 "36
"
/
1
6
"
R
G
14
0
0
8
"
24
"
/
2
4
"
R
G
24
"
/
2
4
"
R
G
1
2
"
96
"
/
2
4
"
L
O
U
V
E
R
72
"
/
2
4
"
L
O
U
V
E
R
M3
0
3
PL
A
N
V
I
E
W
8
"
30
"
/
8
"
S
G
27
5
1 6 "/8 "
48
"
/
6
"
R
G
48
"
/
6
"
R
G
48
"
/
6
"
R
G
48
"
/
6
"
R
G
48
"
/
6
"
R
G
48
"
/
6
"
R
G
48
"
/
6
"
R
G
48
"
/
6
"
R
G
24
"
/
2
4
"
ID
F
R
O
O
M
D1
0
4
A
EF
-
A
1
2
"
19
0
19
0
19
0
19
0
19
0
19
0
19
0
19
0
1
2
2
3
3
2
EW
H
-
A
2
3K
W
EW
H
-
D
3
3K
W
EW
H
-
D
1
3K
W
8 "
10
"
13
9
0
C
F
M
10
0
0
C
F
M
14
0
0
C
F
M
24
"
/
8
"
S
G
20
0
24
"
/
8
"
S
G
20
0
24
"
/
8
"
S
G
20
0
24
"
/
8
"
S
G
20
0
24
"
/
8
"
S
G
20
0
24
"
/
8
"
S
G
20
0
1 8 "
8"
8"
1
0
"
1
2
"
22
5
12
"
/
1
2
"
T
G
8"
1
2
"
48
"
/
6
"
R
G
48
"
/
6
"
R
G
4
4
2 8 "/1 0 "
2 8 "/1 4 "
48
"
/
6
"
R
G
2
4
"
/
1
0
"
7
7
7
5
19
0
19
0
19
0
7
23
0
23
0
23
0
23
0
23
0
23
0
6
EF
-
D
1
1
6
WS
H
P
-
J
-
D
1
1
3
WS
H
P
-
J
-
D
1
0
5
CE
DA
DF
DB
DB
.
8
DE
D4
A1
AA
C1
D5
DC
D1
D2
DD
AC
D3
.
5
D3
AG
.
8
D4
.
3
D4
.
7
DA
.
9
19
0
19
0
19
0
19
0
19
0
2
0
"
/
1
0
"
1
6
"
/
1
0
"
1
0
"
/
1
0
"
2
0
"
/
1
0
"
1
6
"
/
1
0
"
1
0
"
/
1
0
"
8
14
0
14
0 14
0
14
0 14
0
14
0
14
0
14
0
14
0
14
0
1 6 "/1 0 "
1 6 "/1 0 "
1 6 "/1 0 "
1 6 "/1 0 "
9
9
9 9
2
4
"
/
1
4
"
2 4 "/1 4 "
2
6
"
/
1
4
"
1
2
"
/
1
2
"
48
"
/
6
"
R
G
5
10
"
10
"
8"
1
4
"
/
1
2
"
1
4
"
/
1
4
"
1 4 "/1 4 "
2 2 "/1 6 "
1
2
"
/
1
2
"
1
0
"
/
1
0
"
8"
8"
8"
8"8"
2
8
"
/
1
0
"
WS
H
P
-
J
-
D
1
1
7
J M4
0
1
J M4
0
1
4
4
10
10
PLAN NOTES:#PLAN NOTES:1.PROVIDE 36"x24"x24" DEEP INSULATED PLENUM ON BACK OF LOUVER.CONNECT EXHAUST AIR DUCTS TO LOUVER. BLANK OFF UNUSED LOUVER WITH 2" RIGID INSULATION AND SHEET METAL. SEAL WATER-TIGHT.2. OFFSET E.A. DUCT DOWN AND INSTALL FAN MAXIMUM 12" ABOVE LAYIN CEILING.3.ROUTE DUCTWORK IN TRUSS OPENINGS.4.LINEAR SLOT DIFFUSER LIKE PRICE SDS50, 1 SLOT, 1/2" SLOT WIDTH, 48"LENGTH, 8" INLET, SDA PLENUM. TYPICAL.5.LINEAR SLOT DIFFUSER LIKE PRICE SDS50, 1 SLOT, 1/2" SLOT WIDTH, 48"LENGTH, 8" INLET, SDA PLENUM. TYPICAL.6.LINEAR SLOT DIFFUSER LIKE PRICE SDS50, 1 SLOT, 1/2" SLOT WIDTH, 48"LENGTH, 8" INLET, SDA PLENUM. TYPICAL.7.LINEAR BAR GRILLE IN BULKHEAD LIKE PRICE LBP-15B. CLEAR ANODIZED ALUMINUM. TYPICAL.8.OFFSET DUCTWORK AS REQUIRED IN THIS AREA TO AVOID STRUCTURE.9.BALANCED DUCTWORK INSTALLED IN THIS AREA MUST BE OPERATIONAL AND BALANCED PRIOR TO INSTALLATION OF CEILING SYSTEM.10.LINEAR SLOT RETURN DIFFUSER LIKE PRICE SDR50, 1 SLOT, 1/2" SLOT WIDTH,48" LENGTH. TYPICAL.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD
8/28/2015 6:59:25 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt
M201DLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA D - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner
NO
R
T
H
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
FI
R
S
T
F
L
O
O
R
-
A
R
E
A
D
-
M
E
C
H
A
N
I
C
A
L
OP
E
N
O
F
F
I
C
E
B2
1
9
EL
E
C
T
R
I
C
A
L
B2
2
0
ST
O
R
A
G
E
B2
2
1
ST
O
R
A
G
E
B2
1
2
CO
N
F
E
R
E
N
C
E
B2
0
3
PU
B
L
I
S
H
I
N
G
B2
0
5
PU
B
L
I
S
H
I
N
G
B2
0
7
VP
P
U
B
L
I
S
H
I
N
G
B2
0
9
PU
B
L
I
S
H
I
N
G
B2
0
8
PU
B
L
I
S
H
I
N
G
B2
0
6
PU
B
L
I
S
H
I
N
G
B2
0
4
VP
-
A
C
C
O
U
N
T
I
N
G
B2
2
6
AC
C
O
U
N
T
I
N
G
B2
2
7
HR
O
F
F
I
C
E
B2
2
9
UN
A
S
S
I
G
N
E
D
B2
3
0
UN
A
S
S
I
G
N
E
D
B2
3
1
ST
O
R
A
G
E
B2
1
7
IT
O
F
F
I
C
E
B2
3
5
GO
V
E
R
N
O
R
'
S
R
O
O
M
B2
0
2
WO
M
E
N
B2
1
6
ME
N
B2
1
5
UN
A
S
S
I
G
N
E
D
B2
2
3
PU
B
L
I
S
H
I
N
G
B2
1
0
AC
C
O
U
N
T
I
N
G
B2
2
4
32
0
32
0
47
5
21
0
22
0
21
0
22
5
22
5
42
0
20
0
20
0
20
0
20
0
12
5
25
0
25
0
12
5
15
0
15
0
20
0
20
0
24
0
20
0
40
0
24
0
23
0
29
0
29
0
29
0
29
0
29
0
20
0
15
0
32
5
20
0
12
"
/
1
2
"
E
R
35
0
12
"
/
1
2
"
E
R
35
0
20
0
20
0
1
M3
0
1
2
M3
0
1
18"/18"
18"/18"
16"/12"
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
24
"
/
1
2
"
R
G
M3
0
1
B2
1
8
CO
R
R
I
D
O
R
B2
1
4
ST
A
I
R
B2
0
0
CO
R
R
I
D
O
R
B2
1
1
OP
E
N
O
F
F
I
C
E
B2
2
2
CO
R
R
I
D
O
R
B2
0
1
CO
R
R
I
D
O
R
B2
3
6
WO
R
K
R
O
O
M
B2
1
3
B2
0
1
A
B2
3
6
A
16"/10"
10"
10"/10"
IT
O
F
F
I
C
E
B2
3
4
UN
A
S
S
I
G
N
E
D
B2
3
3
UN
A
S
S
I
G
N
E
D
B2
3
2
16"/10"
10"
10"
10"
22"/10"
12"/10"
22"/10"
10"
10"
20"/10"
10"
10"
10"
22"/10"
10"
10"
10"
10"
10"
10"
10"
10"
10"
12"/10"
18"/12"
24"/12"
12"
/10"
8"
8"
10"/10"
12"/8"
8"
8"
29
0
WS
H
P
-
O
-
B
2
0
2
WS
H
P
-
L
-
B
2
0
3
WS
H
P
-
N
-
B
2
0
5
WS
H
P
-
O
-
B
2
0
9
WS
H
P
-
N
-
B
2
2
3
WS
H
P
-
O
-
B
2
2
6
WS
H
P
-
O
-
B
2
3
0
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
24
"
/
2
4
"
WS
H
P
-
L
-
B
2
3
5
WS
H
P
-
P
-
B
2
1
2
WS
H
P
-
U
-
B
2
1
5
BB
BB
BB
BB
BB
BB
BB
BB
BB
CC
AA
AA
DD
BB
BB
BB
BB
BB
DD
BB
BB
16"/10"
BA BB BC BD
B6
B3
B4
B5
B7
B4
.
3
B4
.
8
B1
B2
B1
.
6
B2
.
4
B5
.
7
BA.6 BC.4
1
2
16"/12"
16"/12"
10"
5
5
9
10
8"
4
8"
8
6
8"/8"
8"/6"
4
3
24
"
/
1
2
"
R
G
8"
EF
-
B
2
2
0
24
"
/
1
2
"
R
G
7
7
23
0
8"
8"
8"
8"
10"
ME
C
H
A
N
I
C
A
L
B2
1
8
5
J M4
0
1
J M4
0
1
J M4
0
1
J M4
0
1
J M4
0
1
PLAN NOTES:#PLAN NOTES:1.18/18 O.A. INTAKE DUCTWORK UP AND CONNECT TO INSULATED PLENUM ON BACK OF 60/12 LOUVER. INSTALL LOUVER HIGH AS POSSIBLE.2.18/18 EXHAUST AIR DUCTWORK UP AND CONNECT TO INSULATED PLENUM ON BACK OF 60/12 LOUVER. INSTALL LOUVER HIGH AS POSSIBLE.3.BALANCE BRANCH VENTILATION AIR DUCT TO 40 CFM.4.BALANCE BRANCH VENTILATION AIR DUCT TO 80 CFM.5.BALANCE BRANCH VENTILATION AIR DUCT TO 120 CFM.6.ROUTE 6" VENTILATION AIR DUCT FROM WSHP-OA SUPPLY IN MECHANICAL ROOM TO RETURN AIR INLET. BALANCE TO 80 CFM.7.PROVIDE FIRE DAMPER IN DUCTWORK AT WALL PENETRATION.8.BALANCE BRANCH VENTILATION AIR DUCT TO 160 CFM.9.BALANCE BRANCH VENTILATION AIR DUCT TO 230 CFM.10.BALANCE BRANCH VENTILATION AIR DUCT TO 580 CFM.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD
8/28/2015 5:20:09 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt
M202BLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 SECOND FLOOR -AREA B -MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner
NO
R
T
H
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
SE
C
O
N
D
F
L
O
O
R
-
A
R
E
A
B
-
M
E
C
H
A
N
I
C
A
L
UP
P
E
R
L
I
B
R
A
R
Y
C2
0
0
A/
V
S
P
A
C
E
C2
0
6
1
M2
0
1
C
72
"
/
3
0
"
R
G
38
0
0
72
"
/
3
0
"
R
G
38
0
0
2
2
3
8
48
"
/
4
"
28
5
48
"
/
4
"
28
5
AR
C
H
I
V
E
C2
0
4
ST
O
R
A
G
E
C2
0
3
ME
C
H
A
N
I
C
A
L
C2
0
5
8"
24
"
/
1
2
"
R
G
17
5
17
5
18
"
/
1
8
"
10
"
/
1
0
"
12
"
/
1
0
"
24
"
/
1
2
"
R
G
27
0
12
4
"
/
4
"
28
5
12
4
"
/
4
"
28
5
48
"
/
4
"
28
5
48
"
/
4
"
28
5
12
4
"
/
4
"
28
5
12
4
"
/
4
"
28
5
1
1
1
1
1
5
1
1
5
5
1
5
1
1
1
WS
H
P
-
K
-
C
2
0
4
16
"
/
1
0
"
10"/10"
WS
H
P
-
L
-
C
2
0
6
EC
S
-
A
CA CE
C7
.
9
C5
.
1
C5
.
9
C3
.
1
B1
CDCB
C6
A3
C5
C4
C3
C7
C8
DA
A5
A1
CJCH
CF
CG
C1
C2
C9CC
D5
A2
C2
.
5
C8
.
5
AG
.
8
CG
.
9
D4
.
3
D4
.
7
C7
.
5
C3
.
5
22
"
/
1
2
"
10
0
12"
12
"
/
1
2
"
6
14
"
/
1
8
"
6
7
9
10
48
"
/
4
"
TY
P
.
48
"
/
4
"
TY
P
.
WS
H
P
-
L
-
C
1
0
4
J M4
0
1
J M4
0
1
8"
PLAN NOTES:#PLAN NOTES:1.DOUBLE DEFLECTION SUPPLY AIR GRILLE WITH OPPOSED BLADE DAMPER. CUSTOM COLOR AND FINISH AS SELECTED BY ARCH. BLANK OFF UNUSED PORTIONS OF GRILLES.2.RETURN AIR GRILLE LIKE TITUS 350ZRL OR EQUAL. PROVIDE FIRE DAMPER ON BACK OF GRILLE. ELEVATION OF GRILLE TO BE CLOSELY COORDINATED WITH WALL CONSTRUCTION. REFER TO ARCHITECTURAL ELEVATIONS FOR GRILLE LOCATION.CONNECT RETURN AIR DUCT FROM BELOW TO PLENUM.3.TRANSITION DUCTWORK AT FLOOR.4.MAINTAIN FULL ACCESS TO ROOF HATCH IN THIS AREA.5.SUPPLY GRILLE NOT USED.6.DUCTWORK TO BE INTERNALLY LINED WITH 1" ACOUSTICAL DUCT LINER.7.MAINTAIN CLEARANCES TO ROOF ACCESS IN THIS AREA. SEE A-SERIES DWGS.8.S.A. AND R.A.DUCTWORK DOWN TO FIRST FLOOR IN CHASE. PROVIDE FIRE DAMPER WITH ACCESS AT CHASE PENETRATIONS. SEE M201C FOR CONTINUATION.9.10/10 VENTILATION AIR DUCT DOWN TO FIRST FLOOR.10.BALANCE MANUAL VOLUME DAMPER IN BRANCH DUCT TO 50 CFM FOR EACH WSHP.CONNECT VENTILATION AIR DUCT TO WSHP RETURN AIR DUCTWORK.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD
8/28/2015 5:20:49 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt
M202CLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 SECOND FLOOR -AREA C -MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner
NO
R
T
H
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
SE
C
O
N
D
F
L
O
O
R
-
A
R
E
A
C
-
M
E
C
H
A
N
I
C
A
L
T
T
TT
T
T
PLAN NOTES:#PLAN NOTES:
1.3" GS & GR PIPING UP TO FIRST FLOOR.
2.1-1/2" GS & GR, AND 1" CONDENSATE PIPING UP TO FIRST FLOOR.
3.ALL GS & GR PIPING INSTALLED IN LOWER LIBRARY C001 SHALL BE
DOUBLE CONTAINMENT PIPE.
4.ROUTE CONDENSATE TO MOP SINK.
5.3/4" HS & HR PIPING UP TO FINNED TUBE RADIATION ON LEVEL ABOVE.
SEE M211C FOR CONTINUATION.
GENERAL NOTES:
G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.
IT WORK ROOM
C010STORAGE
C011
ELEV EQUIP
C002
CORRIDOR
C004
IT STORAGE
C007
MDF
C008
STAIR
C005
STORAGE
C003
STAIR
C014
1
2
3"
1-1/2"
3"
1-1/2"
M312
1
3
3
ELECTRICAL ROOM
C001A
1"
1"
1"
5
5
55
1"
3"
1"
1-1/4"
1"
1"
1"
WSHP-L-C001A
WSHP-N-A107
WSHP-N-A109
WSHP-N-C108
WSHP-L-C004
BA
CA
CE
C7.9
C5.1 C5.9
C3.1
B1
CD
CB
C6A3C5C4C3 C7 C8
DA
DB
A5
A1
AA AE
CJ
CH
CF
CG
C2
C9
CC
D5
B1.6
A4
BA.6
C2.5 C8.5
AG.8
CG.9
D4.7
C7.5C3.5
HS
HR
D
D
D D
D
EF-C002
J
M411
WSHP-L-C004
WSHP-E-C011 WSHP-E-C010
1-1/2"
D D
4
EF-C008
D
CO
D
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
Date:Issue:
07/20/15 BID PACKAGE #1
KEYPLAN
A B
C
D
8/
2
8
/
2
0
1
5
4
:
1
1
:
1
0
P
M
C:
\
U
s
e
r
s
\
s
f
i
t
e
s
\
D
o
c
u
m
e
n
t
s
\
1
4
0
4
3
-
L
I
B
E
R
T
Y
F
U
N
D
H
Q
M
E
P
_
s
f
i
t
e
s
.
r
v
t
M210C
LI
B
E
R
T
Y
F
U
N
D
H
E
A
D
Q
U
A
R
T
E
R
S
CA
R
M
E
L
,
I
N
D
I
A
N
A
08/28/2015 BID PACKAGE #2
LOWER LEVEL - AREA
C - MECHANICAL
PIPING
14043
08/28/15
MJE
MJE
MEP Engineers DA#14043
R.E. Dimond and Associates, Inc.
732 North Capitol Avenue
Indianapolis, Indiana 46204
317.634.4672
LIBERTY FUND HEADQUARTERS
Owner
NORTH
SCALE: 1/8" = 1'-0"
LOWER LEVEL - MECHANICAL PIPING
DN
T
T
T
T
T
T
T
H
VESTIBULE
A100
MEN
A112 WOMEN
A113
CLOSET
A103
OFFICE
A104
STORAGE
A102
PICK-UP/STORAGE
A114
3"
3"
4"
CONFERENCE
A109
CONFERENCE
A107 WSHP-N-A107
WSHP-N-A109
WSHP-O-A104
WSHP-U-A101
WSHP-N-A114
SEE M211D FOR
CONTINUATION.
SEE M211B FOR
CONTINUATION.
CORRIDOR
A108
WSHP-U-A106
WSHP-U-A104
1-1/4"
1-1/4"
3"
1"
3"
3"
1-1/4"
BA
BB
BC
CE
C7.9
C5.1 C5.9
C3.1
BD
B1
A3
DA
DF
DB
DB.8
DE
A1.1 A4.9
A1.9 A4.1
AD AH
A5
A1
AA AE
AB AF
D5
B1.6
A2
A4
AC AG
BA.6
BC.4
AC.6 AG.6
AE.5
DA.10
DA.11 DA.14
WSHP-U-A106
WSHP-O-A104
WSHP-N-A114
WSHP-U-A101
1
J
M411
J
M411
D
2
D
PLAN NOTES:#PLAN NOTES:
1.ROUTE PIPING ABOVE CEILING. SPACE IS LIMITED. COORDINATE
LOCATION WITH ALL TRADES.
2.LOCATE ISOLATION VALVES ABOVE ACCESSIBLE CEILING.
GENERAL NOTES:
G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
Date:Issue:
07/20/15 BID PACKAGE #1
KEYPLAN
A B
C
D
8/
2
8
/
2
0
1
5
4
:
1
4
:
0
9
P
M
C:
\
U
s
e
r
s
\
s
f
i
t
e
s
\
D
o
c
u
m
e
n
t
s
\
1
4
0
4
3
-
L
I
B
E
R
T
Y
F
U
N
D
H
Q
M
E
P
_
s
f
i
t
e
s
.
r
v
t
M211A
LI
B
E
R
T
Y
F
U
N
D
H
E
A
D
Q
U
A
R
T
E
R
S
CA
R
M
E
L
,
I
N
D
I
A
N
A
08/28/2015 BID PACKAGE #2
FIRST FLOOR - AREA
A - MECHANICAL
PIPING
14043
08/28/15
MJE
MJE
MEP Engineers DA#14043
R.E. Dimond and Associates, Inc.
732 North Capitol Avenue
Indianapolis, Indiana 46204
317.634.4672
LIBERTY FUND HEADQUARTERS
Owner
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR - MECHANICAL PIPING
T
T
T
T
T
T
T
T
T
T
T
T
MA
C
H
I
N
E
B1
3
2
UN
A
S
S
I
G
N
E
D
B1
2
9
FE
L
L
O
W
B1
2
5
FE
L
L
O
W
B1
2
7
FE
L
L
O
W
B1
2
3
FE
L
L
O
W
B1
0
8
FE
L
L
O
W
B1
0
6
FE
L
L
O
W
B1
0
2
FE
L
L
O
W
B1
0
4
CH
A
I
R
M
A
N
B1
0
0
AS
S
I
S
T
A
N
T
B1
3
1
WO
M
E
N
B1
1
0
ME
N
B1
1
1
ME
C
H
A
N
I
C
A
L
B1
3
4
OF
F
I
C
E
B1
3
0
FE
L
L
O
W
B1
0
3
FE
L
L
O
W
B1
0
1
FE
L
L
O
W
B1
0
5
FE
L
L
O
W
B1
0
7
FE
L
L
O
W
B1
2
2
FE
L
L
O
W
B1
2
6
UN
A
S
S
I
G
N
E
D
B1
2
8
OF
F
I
C
E
B1
2
0
EN
C
L
A
V
E
B1
1
9
WE
L
L
N
E
S
S
RO
O
M
B1
1
3
ST
O
R
A
G
E
/
FU
T
U
R
E
A
S
T
.
B1
1
7
ST
O
R
A
G
E
B1
1
6
EL
E
C
T
B1
1
5
WO
R
K
A
R
E
A
B1
1
4
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
2
1
A
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
1
8
A
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
1
8
B
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
0
9
A
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
1
2
B
FE
L
L
O
W
S
AS
S
I
S
T
A
N
T
B1
1
2
A
CO
R
R
I
D
O
R
B1
1
2
3"
1-1
/
2
"
3"
M3
1
1
1
WS
H
P
-
K
-
B
1
0
0
WS
H
P
-
N
-
B
1
0
1
WS
H
P
-
O
-
B
1
0
5
WS
H
P
-
X
-
B
1
1
7
WS
H
P
-
P
-
B
1
1
6
WS
H
P
-
L
-
B
1
1
9
WS
H
P
-
R
-
B
1
1
4
WS
H
P
-
M
-
B
1
2
2
WS
H
P
-
N
-
B
1
2
6
WS
H
P
-
O
-
B
1
2
9
2"
1"
1-
1
/
4
"
2"
1"
1-1
/
4
"
1-
1
/
4
"
1-
1
/
4
"
1"
WS
H
P
-
N
-
B
1
0
1
WS
H
P
-
O
-
B
1
0
5
WS
H
P
-
M
-
B
1
2
2
WS
H
P
-
N
-
B
1
2
6
WS
H
P
-
O
-
B
1
2
9
WS
H
P
-
R
-
B
1
1
4
WS
H
P
-
P
-
B
1
1
6
WS
H
P
-
L
-
B
1
1
9
1"
1-
1
/
2
"
SE
E
M
2
1
1
A
F
O
R
CO
N
T
I
N
U
A
T
I
O
N
1-
1
/
2
"
1"
BA BB BC BD
B6
B3
B4
B5
B7
B4
.
3
B4
.
8
B1
B2AH
B1
.
6
B2
.
4
B5
.
7
BA.6 BC.4
EF
-
B
1
3
2
EF
-
B
1
1
5
2"
J M4
1
1
CO
D
D
D
D
D
WS
H
P
-
K
-
B
1
0
0
D
D
1-
1
/
4
"
1-1
/
2
"
1"
1"1"
1"
1"
PLAN NOTES:#PLAN NOTES:1.PLAN NOTE #1.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD
8/31/2015 8:59:17 AM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt
M211BLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA B - MECHANICAL PIPING1404308/28/15 MJE MJEMEP Engineers DA#14043R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204317.634.4672LIBERTY FUND HEADQUARTERSOwner
NO
R
T
H
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
FI
R
S
T
F
L
O
O
R
-
A
R
E
A
B
-
M
E
C
H
A
N
I
C
A
L
P
I
P
I
N
G