Loading...
HomeMy WebLinkAbout4522_0007_LIBERTYFUND_BIDPACK2_DRAWINGS_08282015_2NOT FOR CONSTRUCTION PROJECT NUMBER DATE DRAWN BY CHECKED BY PRELIMINARY NOT FOR CONSTRUCTION Date:Issue: 8/ 2 8 / 2 0 1 5 9 : 3 8 : 0 5 P M C: \ U s e r s \ T A l l e n \ D o c u m e n t s \ 4 5 2 2 - 0 0 7 _ L i b e r t y F u n d - C E N T R A L _ T O N Y _ L O CA L _ 0 7 2 9 2 0 1 5 . r v t 45 2 2 - 0 0 0 7 / B I D P A C K A G E # 2 / 0 8 / 2 8 / 1 5 CARMEL, INDIANA 08/28/15 BID PACKAGE #2 LIBERTY FUND HEADQUARTERS 002 LI B E R T Y F U N D H E A D Q U A R T E R S CA R M E L , I N D I A N A 08/28/15 / BID PACKAGE #2 COVER SHEET - VOLUME 2 4522-0007 08/28/15 JMS ER LIBERTY FUND HEADQUARTERS LIBERTY FUND 111th AND PENNSYLVANIA STREET CARMEL, INDIANA 46032 111th AND PENNSYLVANIA STREET Liberty Fund 8335 Allison Point Trail, Suite 300 Indianapolis, Indiana 46250 317-842-0880 Owner Rowland Design, Inc. 702 North Capitol Avenue Indianapolis, Indiana 46250 317-636-3980 Architecture / Landscape / Interior Design Enverity Engineering 9229 Delegates Row, Suite 150 Indianapolis, Indiana 46240 317-706-2075 Site / Civil Engineer CE Soultions 10 Shoshone Drive Carmel, Indiana 46032 317-818-1912 Structural Engineer Dimond Engineering 732 North Capitol Avenue Indianapolis, Indiana 46204 317-634-4672 Mechanical / Eleictrical / Plumbing Engineer Context Design 12 South Main Street, Suite 200 Fortville, Indiana 46040 317-485-6900 Landscape Design 27 Technology & Acoustics 5366 Winthrop Avenue Indianapolis, Indiana 46220 317-485-8000 Technology VOLUME 2 BID PACKAGE No. 2 PROJECT NUMBER DATE DRAWN BY CHECKED BY PRELIMINARY NOT FOR CONSTRUCTION 8/ 3 1 / 2 0 1 5 1 1 : 0 7 : 1 6 A M C: \ U s e r s \ T A l l e n \ D o c u m e n t s \ 4 5 2 2 - 0 0 7 _ L i b e r t y F u n d - C E N T R A L _ T O N Y _ L O CA L _ 0 7 2 9 2 0 1 5 . r v t A000B LI B E R T Y F U N D H E A D Q U A R T E R S CA R M E L , I N D I A N A BP2 INDEX 4522-0007 08/28/15 Author Checker LIBERTY FUND HEADQUARTERS LIBERTY FUND NO.DESCRIPTIONDATE SHEET INDEX - VOLUME 2 SHEET #SHEET NAME REV DATE E100SITE PLAN - ELECTRICAL E200CLOWER L EVEL - AREA C - LIGHTING E201AFIRST FLOOR - AREA A - LIGHTING E201BFIRST FLOOR - AREA B - LIGHTING E201CFIRST FLOOR - AREA C - LIGHTIN E201DFIRST FLOOR - AREA D - LIGHTING E202BSECOND FLOOR - AREA B - LIGHTING E202CSECOND FLOOR - AREA C - LIGHTING E210CLOWER LEVEL - AREA C - POWER E211BFIRST FLOOR - AREA B - POWER E211CFIRST FLOOR - AREA C - POWER E211DFIRST FLOOR - AREA D - POWER E212BSECOND FLOOR - AREA B - POWER E212CSECOND FLOOR - AREA C - POWER E220CLOWER L EVEL - AREA C - FIRE ALARM E221AFIRST FLOOR - AREA A - FIRE ALARM E221BFIRST FLOOR - AREA B - FIRE ALARM E221CFIRST FLOOR - AREA C - FIRE ALARM E221DFIRST FLOOR - AREA D - FIRE ALARM E222BSECOND FLOOR - AREA B - FIRE ALARM E222CSECOND FLOOR - AREA C - FIRE ALARM E301MECHANICAL ROOM - ELECTRICAL E401DETAILS - ELECTRICAL E501SINGLE-LINE DIAGRAM E601SCHEDULES - ELECTRICAL E211AFIRST FLOOR - AREA A - POWER SHEET INDEX - VOLUME 2 SHEET #SHEET NAME REV DATE GENERAL 002COVER SHEET - VOLUME 2 A000BBP2 INDEX MECHANICAL MP001SYMBOLS AND ABBREVIATIONS M200CLOWER LEVEL - AREA C - MECHANICAL M201AFIRST FLOOR - AREA A - MECHANICAL M201BFIRST FLOOR - AREA B - MECHANICAL M201CFIRST FLOOR - AREA C - MECHANICAL M201DFIRST FLOOR - AREA D - MECHANICAL M202BSECOND FLOOR - AREA B - MECHANICAL M202CSECOND FLOOR - AREA C - MECHANICAL M210CLOWER LEVEL - AREA C - MECHANICAL M211AFIRST FLOOR - AREA A - MECHANICAL PIPING M211BFIRST FLOOR - AREA B - MECHANICAL PIPING M211CFIRST FLOOR - AREA C - MECHANICAL PIPING M211DFIRST FLOOR - AREA D - MECHANICAL PIPING M212BSECOND FLOOR - AREA B - MECHANICAL PIPING M212CSECOND FLOOR - AREA C - MECHANICAL PIPING M301ENLARGED MECH. ROOMS B134 & B218 - MECHANICAL M302ENLARGED MECHANICAL ROOM C013 - MECHANICAL M303ENLARGED MECHANCIAL ROOM D104 - MECHANICAL M311ENLARGED MECH. ROOMS B134 & B218 - MECHANICAL PIPING M312ENLARGED MECHANICAL ROOM C013 - MECHANICAL PIPING M313ENLARGED MECHANICAL ROOM D104 - MECHANICAL PIPING M401DETAILS - AIR DISTRIBUTION M411DETAILS - LIQUID TRANSFER M511 M601SCHEDULES - AIR DISTRIBUTION M611SCHEDULES - LIQUID HEAT TRANSFER M701CONTROL SCHEMATICS M702CONTROL SCHEMATICS PLUMBING P200AFOUNDATION - AREA A - PLUMBING P200BFOUNDATIONA - AREA B - PLUMBING P200CFOUNDATION - AREA C - PLUMBING P200C-1LOWER LEVEL - AREA C - PLUMBING P200DFOUNDATION - AREA D - PLUMBING P201AFIRST FLOOR - AREA A - PLUMBING P201BFIRST FLOOR - AREA B - PLUMBING P201CFIRST FLOOR - AREA C - PLUMBING P201DFIRST FLOOR - AREA D - PLUMBING P202BSECOND FLOOR - AREA B - PLUMBING P202CSECOND FLOOR - AREA C - PLUMBING P210OVERALL ROOF PLAN - PLUMBING P302ENLARGED MECHANICAL ROOM C013 - PLUMBING P303ENLARGED MECHANICAL ROOM D104 - PLUMBING P601SCHEDULES - PLUMBING FIRE PROTECTION FP200CLOWER LEVEL - AREA C - FIRE PROTECTION FP201AFIRST FLOOR - AREA A - FIRE PROTECTION FP201CFIRST FLOOR - AREA C - FIRE PROTECTION FP201BFIRST FLOOR - AREA B - FIRE PROTECTION FP201DFIRST FLOOR - AREA D - FIRE PROTECTION FP202BSECOND FLOOR - AREA B - FIRE PROTECTION FP202CSECOND FLOOR - AREA C - FIRE PROTECTION ELECTRICAL E001SYMBOLS & ABBREVIATIONS - ELECTRICAL TECHNOLOGY T100 GENERAL NOTES AND LEGENDS T001 BASEMENT DISTRIBUTION PLAN T002 FIRST FLOOR - DISTRIBUTION PLAN T003 SECOND FLOOR - DISTRIBUTION PLAN T100 OVERALL BASEMENT T101 FIRST FLOOR - AREA A T102 FIRST FLOOR - AREA B T103 FIRST FLOOR - AREA C T104 FIRST FLOOR - AREA D T105 SECOND FLOOR - AREA A T106 SECOND FLOOR - AREA B T107 SECOND FLOOR - AREA C T200 ENLARGED TECHNOLOGY ROOMS T300 TELECOM RISER AND GROUNDING DIAGRAMS T400 AV SCHEMATIC DIAGRAMS T401 AV SCHEMATIC DIAGRAMS T410 SECURITY AND ACCESS CONTROL SCHEMATIC DIAGRAMS T500 TELECOM DETAILS T501 AV DETAILS T502 AV DETAILS T503 AV DETAILS T504 AV DETAILS T510 SECURITY AND ACCESS CONTROL DETAILS CHARGING VALVE SIGHT GLASS FILTER-DRYER BARE PIPE IN COVER RADIATION COVER ONLY FINNED TUBE RADIATION FINNED TUBE RADIATION IN COVER THERMOSTATIC EXPANSION VALVE EVAPORATOR PRESSURE REGULATOR MANUAL REFRIGERATION VALVE STRAINER FLANGED CONNECTION SIAMESE HOSE CONNECTION PIPE ANCHOR EXPANSION JOINT PIPE ALIGNMENT GUIDES UNION END CAP CONCENTRIC REDUCER TEE DOWN TEE UP ELBOW DOWN ELBOW UP TEMPERATURE SENSOR HUMIDISTAT DUCT THERMOSTAT (ELECTRIC) ROOM THERMOSTAT (HEAT/COOL) ROOM THERMOSTAT (COOL) DUCT THERMOSTAT (PNEUMATIC) FLOW METER MOTORIZED DAMPER DIFFERENTIAL PRESSURE TRANSMITTER ROOM THERMOSTAT (HEAT) SAFETY/PRESSURE RELIEF VALVE FLOW CONTROL VALVE MAKEUP WATER VALVE PRESSURE REDUCING VALVE CHECK VALVE BALANCING VALVE VERTICAL SHUT-OFF/NEEDLE VALVE SHUT-OFF VALVE SHOCK ABSORBER AIR CHAMBER (DOWN IN ARROW DIRECTION) PIPE PITCH ARROW PRESSURE GAUGE AUTOMATIC AIR VENT COMPOUND GAUGE FLEX CONNECTOR CONDENSER WATER RETURN GROUND LOOP WATER RETURN REFRIGERANT DISCHARGE REFRIGERANT SUCTION REFRIGERANT LIQUID CONDENSER WATER SUPPLY CHILLED WATER SUPPLY CHILLED WATER RETURN GROUND LOOP WATER SUPPLY AUTOMATIC AIR VENT PENDANT SPRINKLER HEAD UPRIGHT SPRINKLER HEAD FIRE PROTECTION PIPING POST INDICATOR VALVE FIRE HYDRANT OXYGEN VACUUM LINE ACID WASTE (SUSPENDED) ACID WASTE (BURIED) DISTILLED WATER ACID VENT DEIONIZED WATER FUEL OIL RETURN FUEL OIL SUPPLY INVERTED BUCKET TRAP FLOAT & THERMOSTATIC TRAP HEATING WATER RETURN HEATING WATER SUPPLY LOW PRESSURE CONDENSATE RETURN LOW PRESSURE STEAM RETURN OR EXHAUST DUCT DOWN RETURN OR EXHAUST DUCT UP FIRE DAMPER (FD) IN DUCT SUPPLY DUCT DOWN VOLUME DAMPER SUPPLY DUCT UP FUEL OIL VENT NITROGEN NITROUS OXIDE FLOW ARROW TEMP/PRESSURE RELIEF VALVE CONCEALED SPRINKLER HEAD DRY STANDPIPE DRY PIPE SPRINKLER PIPING PRE-ACTION SPRINKLER PIPING ELBOW TEE CLEANOUT FLOOR DRAIN STORM WATER (SUSPENDED) TEMPERED WATER GAS DRAIN LINE SANITARY WASTE (SUSPENDED) SANITARY WASTE (BURIED) SANITARY VENT LINE STORM WATER (BURIED) COLD SOFT WATER HOT WATER (180° F) HOT WATER RETURN (140° F) HOT WATER (140° F) HOT WATER RETURN HOT WATER 140° GAS METER WATER METER TAMPER SWITCH FLOW SWITCH OXYGEN OUTLET MEDICAL AIR OUTLET NITROGEN OUTLET NITROUS OXIDE OUTLET VACUUM OUTLET SLIDE MEDICAL AIR PIPE SLEEVE HOT SOFT WATER HOT SOFT WATER RETURN CONTROL VALVE (TCV) 3-WAY CONTROL VALVE WET FIRE PROTECTION PIPING ALARM CHECK VALVE REFRIGERANT HOT GAS HOT WATER RETURN (180° F) MEDIUM PRESSURE STEAM HIGH PRESSURE STEAM MEDIUM PRESSURE CONDENSATE RETURN HIGH PRESSURE CONDENSATE RETURN THERMOSTATIC TRAP THROTTLING VALVE PETE'S PLUG FD CARBON DIOXIDE SENSOR VARIABLE FREQUENCY DRIVE TEMPERATURE CONTROL PANEL ACCESS PANEL BOILER FEED WATER EMERGENCY BOILER FEED WATER COLD WATER 140° 180° 180° T CSW HSW HSWR NON-POTABLE WATERNPW G AIR (WITH PSI)A D GM WM RPBP RPZ (REDUCED PRESSURE BACKFLOW PREVENTER) CS CR CHWS CHWR GS GR { HS HR FOS FOR FOV RD RS RL RHG DUAL TEMPERATURE SUPPLYDTS DUAL TEMPERATURE RETURNDTR BFW EBFW LPS MPS HPS LPR MPR HPR CONDENSATE PUMP DISCHARGEPD CONDENSATE RETURNCR F&T IB T ECCENTRICAL REDUCER CO FD FCV D GAS OUTLETG MA O N NO V S MA N O NO V DW AV DI F DS DP PA WP PIV TS FS COMBINATION FIRE/SMOKE DAMPER (FSD) IN DUCT FSD SD SMOKE DAMPER (SD) IN DUCT AP INTERNAL LINED DUCT CO2 FLOW SWITCH FS FM DPT M VFD TCP WELL WATERWW 8"E. DENOTED EXISTING WORK CONNECTION TO EXISTING SECTION OR ELEVATION NUMBER THERMOMETER T C S T H T H,C T C T T E H T DENOTED NEW WORK SIZE OF PIPE OR DUCT DENOTED EXISTING SHEET NUMBER OF SECTION OR ELEVATION DETAIL (LETTER) SHEET NUMBER OF DETAIL LOCATION ADAREA DRAIN AFCAUTOMATIC FLOW CONTROL AFFABOVE FINISHED FLOOR AHRAIR HOSE REEL AHUAIR HANDLING UNIT ALTALTERNATE APACCESS PANEL ASAIR SEPARATOR BDBLOWDOWN BDDBACKDRAFT/PRESSURE RELIEF DAMPER BTUBRITISH THERMAL UNIT BVBALANCE VALVE CBCATCH BASIN CICAST IRON CLCENTERLINE COCLEANOUT CONDCONDENSATE CONVHYDRONIC CONVECTOR CUHCABINET UNIT HEATER CWCOLD WATER DBDRY BULB DFDRINKING FOUNTAIN DIADIAMETER DIFFDIFFUSER DSDOWNSPOUT DXCDIRECT EXPANSION COOLING COIL EAEXHAUST AIR EATENTERING AIR TEMPERATURE EBBRELECTRIC BASEBOARD RADIATION ECELECTRICAL CONCTRACTOR EGEXHAUST GRILLE ECONVELECTRIC CONVECTOR ECUHELECTRIC CABINET UNIT HEATER EFEXHAUST FAN ELECELECTRICAL ELEVELEVATION EOMEND OF MAIN DRIP EPUHELECTRIC PROPELLER UNIT HEATER EREXHAUST REGISTER ERCPELECTRIC RADIANT CEILING PANEL ESPEXTERNAL STATIC PRESSURE EWCELECTRIC WATER COOLER EWHELECTRIC WATER HEATER ETEXPANSION TANK EEXISTING FDFLOOR DRAIN OR FIRE DAMPER FPVAVFAN POWERED VAV FOBFLAT ON BOTTOM FSDCOMBINATION FIRE/SMOKE DAMPER FTRHYDRONIC FINNED TUBE RADIATION GCGENERAL CONTRACTOR GENGENERAL HBHOSE BIBB HTGHEATING HWHOT WATER IDINTERNAL DIAMETER INV. EL.INVERTED ELEVATION LATLEAVING AIR TEMPERATURE LAVLAVATORY MBH1000 BTU/HOUR MECHMECHANICAL MHMANHOLE MCMECHANICAL CONTRACTOR MSMOP SINK MUVAUTOMATIC MAKE-UP VALVE NCNORMALLY CLOSED NONORMALLY OPEN OAOUTSIDE AIR OBDOPPOSED BLADE DAMPER ODOUTSIDE DIAMETER OFDOVERFLOW DRAIN OSDOPEN SITE DRAIN PFHXPLATE AND FRAME HEAT EXCHANGER PIVPOST INDICATOR VALVE PLBGPLUMBING PRVPRESSURE REDUCING VALVE PUHPROPELLER UNIT HEATER RARETURN AIR RCPRADIANT CIELING HEATING PANEL RCNPREINFORCED CONCRETE PIPE RDROOF DRAIN RECIRCRECIRCULATING RGRETURN GRILLE RPZREDUCED PRESSURE BACKFLOW PREVENTER RRRETURN REGISTER RIVROOF INTAKE VENT RRVROOF RELIEF VENT SASUPPLY AIR SANSANITARY SDSMOKE DAMPER SGSUPPLY GRILLE SHDRSHOWER DRAIN SKSINK SRSUPPLY REGISTER SSSTAINLESS STEEL STHXSHELL AND TUBE HEAT EXCHANGER TCCTEMPERATURE CONTROL CONTRACTOR TCPTEMPERATURE CONTROL PANEL TGTRANSFER GRILLE TOTRANSFER OPENING TPTRAP PRIMER LINE TYPTYPICAL URURINAL VAVVARIABLE AIR VOLUME VCPVETRIFIED CLAY PIPE VFDVARIABLE FREQUENCY DRIVE VSVENT STACK VTRVENT THROUGH ROOF WWASTE WBWET BULB WCWATER CLOSET WHWALL HYDRANT WSWASTE STACK ABBREVIATIONSTEMPERATURE CONTROL/MONITORING DRAWING NOTATIONS SECTIONS AND DETAILS RADIATION SYMBOLS DUCT SYMBOLS FIRE PROTECTION SYSTEM MEDICAL STEAM PIPING HVAC PIPING VALVES REFRIGERATION VALVES/FITTINGS PLUMBING PIPE FITTINGS ALL NEW WORK IS DRAWN DARK. THESE NOTES APPLY TO EACH AND EVERY "M" AND "P" SERIES DRAWING. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK WITH ALL OTHER TRADES. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS RELATED TO COORDINATION. COLORS OF EXPOSED UNITS SHALL BE SELECTED BY ARCHITECT. COLORS SHALL BE MANUFACTURER'S STANDARD OR CUSTOM COLOR AS REQUESTED. PROVIDE SLEEVES FOR ALL PIPING AND DUCTWORK THAT PENETRATES FULL HEIGHT WALLS, WHETHER SHOWN OR NOT. SEE SPECIFICATIONS. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARE NOTED ON THOSE DRAWINGS. ALL UNDERLINED EQUIPMENT IS SCHEDULED. SEE M600 & P600 SERIES DRAWINGS FOR SCHEDULES. SEE 'S' SERIES DRAWINGS FOR TYPICAL LINTEL INSTALLATION. CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING, FLUSHING AND FILLING OF PIPING AND SYSTEMS AS REQUIRED. M.C. WILL BE RESPONSIBLE FOR CHEMICAL TREATMENT OF SYSTEMS. THERMOSTATS SHOWN ON EQUIPMENT SHALL BE INSTALLED WITH SENSOR TO SENSE RETURN AIR TEMPERATURE. MOUNT THERMOSTATS WITH BOTTOM AT 48" A.F.F. UNLESS NOTED OTHERWISE. ALL THERMOSTAT LOCATIONS SHALL BE REVIEWED BY ARCHITECT IN FIELD PRIOR TO INSTALLATION. THERMOSTATS IN PRIVATE OFFICES SHALL BE ADJUSTABLE TYPE. THERMOSTATS IN COMMON AREAS SHALL BE SENSORS WITH ADJUSTMENT IN REMOTE LOCATION AS REQUIRED BY OWNER. ACCESS PANELS ARE REQUIRED IN HARD CEILINGS WHETHER SHOWN OR NOT, WHEREVER ACCESS IS REQUIRED TO INSTALL OR SERVICE MECHANICAL EQUIPMENT. SEE 'A' SERIES DRAWINGS AND SPECIFICATIONS. COORDINATE LOCATION WITH REFLECTED CEILING PLAN. CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING AND CUTTING HOLES THRU WALLS AND FLOORS AS REQUIRED TO INSTALL NEW PIPING AND DUCTWORK, WHETHER SHOWN OR NOT. ALL WIRING TO THERMOSTATS SHALL BE ROUTED CONCEALED. WIREMOLD IS NOT ACCEPTABLE. AN ENGRAVED PLASTIC LAMINATE TAG SHALL BE ADHERED TO THE ACOUSTICAL LAY-IN CEILING GRID AT THE LOCATION WHERE ALL TERMINAL DEVICES, VALVES, FANS, ETC. ARE ABOVE THAT CEILING INDICATING THE EQUIPMENT NOMENCLATURE INSTALLED. ROUTE BRANCH CHWS & CHWR, HS & HR PIPING TO EQUIPMENT (MINIMUM 1" UNLESS NOTED AS LARGER) WITH A HYDRONIC COIL WHETHER SHOWN OR NOT. ALL COOLING COILS SHALL HAVE MINIMUM 3/4" CONDENSATE PIPE UNLESS NOTED OTHERWISE. TYPICAL PIPING DETAILS SHALL APPLY. FLEX DUCT CONNECTIONS TO DIFFUSERS SHALL BE A MAXIMUM OF 36" IN LENGTH UNLESS SHOWN OTHERWISE. BRANCH DUCTS SHALL BE 45° BOOT TAP FROM SIDE OF MAIN. NO SPIN-IN FITTINGS. PROVIDE VOLUME DAMPERS IN ALL BRANCH DUCTS TO DIFFUSERS, EXHAUST GRILLES, ETC. WHETHER SHOWN OR NOT. THESE DAMPERS ARE TO BE USED FOR SYSTEM BALANCE. DAMPERS IN DIFFUSERS, REGISTERS, ETC. SHALL NOT BE USED FOR AIR BALANCE UNLESS APPROVED BY ENGINEER. FOR ALL AIR OUTLETS INSTALLED IN HARD CEILINGS, VOLUME DAMPERS SHALL BE LOCATED ABOVE ACCESSIBLE CEILING IN ADJACENT SPACE IF POSSIBLE, IF NOT POSSIBLE THEN LOCATE SO THEY CAN BE ADJUSTED THROUGH THE FACE OF THE AIR OUTLET OR PROVIDE ACCESS PANEL IN CEILING UNLESS NOTED OTHERWISE. SEE REFLECTED CEILING PLAN TO COORDINATE LOCATION OF AIR OUTLETS. COORDINATE COIL CONNECTIONS FOR ALL EQUIPMENT WITH MFG. PRIOR TO ORDERING. REFERENCE M400's FOR TYPICAL AND SPECIFIC INSTALLATION REQUIREMENTS FOR EQUIPMENT, ETC. SUPPLY DIFFUSERS TO BE INSTALLED NO CLOSER THAN 5'-0" TO ALL SMOKE DETECTORS. REFER TO T-SERIES DRAWINGS AND E-SERIES DRAWINGS FOR ADDITIONAL CEILING INSTALLED DEVICES. COORDINATE AND ADJUST DIFFUSER LOCATIONS, AS NEEDED. CONTRACTOR SHALL PROVIDE ALL REQUIRED GAS VENT PIPING WHETHER SHOWN OR NOT. ALL VENT LINES SHALL TERMINATE OUTSIDE OF BUILDING AT 24" ABOVE PARAPET WITH MUSHROOM CAP & INSECT SCREEN. GAS VENT PIPING SHALL BE BLACK IRON. MECHANICAL CONTRACTOR SHALL BLANK-OFF UNUSED PORTIONS OF ALL LOUVERS WHETHER SHOWN OR NOT WITH SHEETMETAL AND 2" OF RIGID INSULATION. WORKMANSHIP FOR ALL DUCTWORK AND EQUIPMENT MUST BE IN COMPLIANCE WITH SMACNA STANDARDS. LOCATE AIR TERMINAL BOXES, VALVES, METERS, GAUGES, DAMPERS, FANS, ETC., ABOVE LAY-IN CEILING OR IN EXPOSED AREAS, IF POSSIBLE. ALL VALVES MUST BE ACCESSIBLE. DO NOT HIDE DEVICES BEHIND WALLS OR PLASTER CEILINGS OR BAR JOISTS. WHERE UNITS MUST BE INSTALLED ABOVE HARD CEILINGS, CONTROL RELAYS OR SIMILAR ACCESSORIES MUST BE LOCATED FOR MAINTENANCE THROUGH THE ACCESS PANEL. SHEETMETAL CONTRACTOR TO PROVIDE DUCT ACCESS FOR FIRE DAMPERS, MOTORIZED DAMPERS, AIR FLOW MEASURING STATIONS, AND ON THE INLET SIDE OF THE REHEAT COILS. COORDINATE WITH MECHANICAL CONTRACTOR AND GENERAL TRADES CONTRACTOR. ALL CEILING HVAC EQUIPMENT WITH A COOLING COIL MUST BE EQUIPPED WITH A SECONDARY DRAIN PAN AND PROPER INDEPENDENT DRAINAGE SYSTEM. DO NOT RUN ANY PIPING, DUCTWORK, OR EQUIPMENT ABOVE THE DATA ROOMS UNLESS APPROVED BY ENGINEER.. ALL FLOOR OR OUTDOOR MOUNTED EQUIPMENT SHALL BE INSTALLED ON A 4" CONCRETE HOUSEKEEPING PAD. CONCRETE PADS FOR ALL HVAC EQUIPMENT MUST BE A FACTORY MIX (NOT BAG MIXED ON SITE). NO PULLED PIPING TEES. USE MANUFACTURED TEES. ALL INTERIOR CONDENSATE DRAINS SHALL TERMINATE WITH 90° ELBOW DIRECTLY OVER DRAIN. TEMPERATURE CONTROL CONTRACTOR SHALL NOTIFY AND COORDINATE MECHANICAL CONTRACTOR OF ALL WELLS NEEDED IN PIPING. ALL SUPPLY AIR AND RETURN AIR GRILLES IN HARD CEILINGS OR WALLS SHALL HAVE CLEAR ANODIZED FINISH. MECHANICAL GENERAL NOTES PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue: 08/28/15 BID PACKAGE #2 KEYPLAN A B C D 8/ 2 8 / 2 0 1 5 5 : 1 1 : 0 5 P M C: \ U s e r s \ v h o b b s \ D o c u m e n t s \ 1 4 0 4 3 - L I B E R T Y F U N D H Q M E P _ v h o b b s . r v t MP001 LI B E R T Y F U N D H E A D Q U A R T E R S CA R M E L , I N D I A N A 08/28/2015 BID PACKAGE #2 SYMBOLS AND ABBREVIATIONS 14043 08/28/15 MJE MJE MEP Engineers DA#14043 R.E. Dimond and Associates, Inc. 732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672 LIBERTY FUND HEADQUARTERS Owner IT W O R K R O O M C0 1 0 ST O R A G E C0 1 1 EL E V E Q U I P C0 0 2 CO R R I D O R C0 0 4 IT S T O R A G E C0 0 7 MD F C0 0 8 ST A I R C0 0 5 ST O R A G E C0 0 3 ST A I R C0 1 4 22 " / 1 4 " 22 " / 1 4 " 36"/12" M3 0 2 C0 1 2 40 " / 1 0 " 40 " / 1 4 " 40 " / 2 0 " 40 " / 1 0 " 40 " / 1 4 " 48"/16" 36"/12" 48 / 1 6 L I N E D R . A . D U C T U P T O L I B R A R Y ME Z Z A N I N E L E V E L W I T H F I R E D A M P E R RA T E D E N C L O S U R E P E N E T R A T I O N . I N S T A L L HI N G E D A C C E S S P A N E L . S E E M 2 0 1 C . 12"/10" 10 " / 1 0 " 18"/14" 12"/12" 20"/10" 48 x 1 6 L I N E D R . A . D U C T U P TO L I B R A R Y M E Z Z A N I N E LE V E L W I T H F I R E D A M P E R AT R A T E D E N C L O S U R E PE N E T R A T I O N . I N S T A L L HI N G E D A C C E S S P A N E L . SE E M 2 0 1 C . 10 / 1 0 V E N T I L A T I O N D U C T UP T O F I R S T F L O O R L E V E L . SE E M 2 0 1 C . 30 0 30 0 24 " / 1 2 " S G 20 0 12 5 12 " / 1 2 " S G 22 5 EL E C T R I C A L R O O M C0 0 1 A 36"/12" 36 " / 1 2 " 8" / 8 " S G 10 0 8" / 8 " R G 8" / 8 " R G 24 " / 8 " T G 26"/12" 26 " / 1 2 " 2 0 " / 1 2 " 2 0 " / 1 2 " 8" 8" 8" 8" 8 " 8 " 8 " 8 " 30 0 30 0 30 0 30 0 30 0 30 0 30 0 30 0 30 0 30 0 8" 8" 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " 24 " / 1 2 " R G 24 " / 1 2 " R G 10 " 10 " 22"/12" 1 2 " / 1 2 " 12 " / 1 2 " T G 1 1 24 " / 1 2 " R G 12 " / 1 2 " S G 40 0 WS H P - N - A 1 0 9 40 " / 2 0 " 2 2 24 " / 2 4 " 15 0 12 " / 1 2 " 15 0 15 0 WS H P - N - A 1 0 7 WS H P - N - C 1 0 8 WS H P - L - C 0 0 1 A WS H P - L - C 0 0 4 CA CE C7 . 9 C5 . 1 C5 . 9 C3 . 1 CDCB C6 C5 C4 C3 C7 C8 DA DB CJCH CF C2 C9 CC C2 . 5 C8 . 5 C7 . 5 C3 . 5 12 " / 1 2 " 2 0 "/1 0 " 2 0 " / 1 0 " 12"/12" 20"/10" 12"/8" 12"/12" 8" 8 "/8 " 3 8 " / 6 " 8 " / 6 " 8"/6" 3 4 4 4 4 12 / 1 0 T O S . G . LO W E R L I B R A R Y C0 0 1 14 " / 1 0 " 5 5 48 " / 1 6 " 24 " / 1 2 " R G EF - C 0 0 8 8" 20"/14" 4 4 4 6 6 6 6 6 EF - C 0 0 2 8" / 8 " 5 36 " / 8 " J M4 0 1 J M4 0 1 J M4 0 1 J M401 J M4 0 1 TY P . PLAN NOTES:#PLAN NOTES:1.INSTALL FIRE DAMPER WITH ACCESS AT DUCT PENETRATION THROUGH RATED WALL ASSEMBLY.2.PROVIDE FIRE DAMPER WITH ACCESS PANEL IN DUCTWORK AT FLOOR PENETRATIONS TO LEVEL ABOVE. MANUAL VOLUME DAMPER IN BRANCH DUCT TAKE-OFF FROM MAIN.3.CONNECT VENTILATION AIR DUCTWORK TO RETURN AIR DUCTWORK. BALANCE TO 75 CFM.4.TRANSITION AND CONNECT DUCTWORK TO LINEAR BAR GRILLE ABOVE. COORDINATE EXACT LOCATION WITH STRUCTURE.5.DUCTED TRANSFER OPENING ABOVE CEILING.6.DUCTWORK TO BE INTERNALLY LINED WITH 1" ACOUSTICAL DUCT LINER.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD 8/28/2015 6:14:11 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt M200CLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 LOWER LEVEL - AREA C - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner NO R T H SC A L E : 1 / 8 " = 1 ' - 0 " LO W E R L E V E L - A R E A C - M E C H A N I C A L DN VE S T I B U L E A1 0 0 ME N A1 1 2 WO M E N A1 1 3 CL O S E T A1 0 3 OF F I C E A1 0 4 ST O R A G E A1 0 2 PI C K - U P / S T O R A G E A1 1 4 EB B R - A EW H - A 1 EB B R - A 42 0 30 0 10 0 44 0 72 " / 2 4 " R G 18 5 0 72 " / 2 4 " R G 18 5 0 EB B R - A EB B R - A 48 " / 4 " R G 64 0 48 " / 4 " S G 64 0 1 1 EB B R - A EB B R - A 1 1 4 4 EB B R - A EB B R - A EB B R - A 1 1 1 EB B R - A EB B R - A EB B R - A 1 1 1 1 3 3 2 5 CO R R I D O R A1 0 8 CO R R I D O R A1 1 0 CO R R I D O R A1 0 6 EN T R Y A1 0 1 CO R R I D O R A1 0 5 CO N F E R E N C E A1 0 7 CO N F E R E N C E A1 0 9 2 48 " / 4 " S G 64 0 48 " / 4 " R G 64 0 2 2 72 " / 6 " S G 40 0 72 " / 6 " S G 40 0 WS H P - O - A 1 0 4 1 4 " / 1 2 " 1 2 " 10 0 10 0 8" 12"/12" WS H P - N - A 1 1 4 6 " 12 " WS H P - U - A 1 0 6 WS H P - U - A 1 0 1 8" 6" 6" A3 AH A5 A1 AA AE AB AF A2 A4 AC AG AC . 6 AG.6AE.5 5 EB B R - A EB B R - A 1 1 1 9' - 0 " 9' - 0 " 9' - 0 " 15 ' - 0 " 15 ' - 0 " 15 ' - 0 " 15 ' - 0 " 18 ' - 0 " 18 ' - 0 " 14 ' - 0 " 14 ' - 0 " 14 ' - 0 " 14 ' - 0 " 9' - 0 " 4 K W 6 6 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 30 0 30 0 30 0 30 0 30 0 30 0 30 0 30 0 EF - A 1 1 3 EF - A 1 1 2 7 8 2 0 " / 6 " 2 0 "/8 " 1 6 " / 6 " 16"/6" 8" 20"/8" 20"/6" 8 " 2 0 " / 8 " 2 4 "/1 4 " 1 6 " / 6 " 1 6 "/6 " 16"/6" 16"/6" 24"/14" J M4 0 1 J M4 0 1 4 10 PLAN NOTES:#PLAN NOTES:1.EBBR-A - DRAFT BARRIER AT BASE OF WINDOW. PEDESTAL MOUNTED. LIKE TPI-9300 DBT SERIES. 100 W/FT. CLEAR ANODIZED FINISH. 12 GA ENCLOSURE.INTEGRAL THERMOSTAT. 3-1/2" MAX DEPTH X 6" TALL. FINISHED BACK AND ENDCAPS. FIELD VERIFY EXACT ENCLOSURE LENGTHS REQUIRED.2.LINEAR SLOT DIFFUSER LIKE PRICE SDS50, 1 SLOT, 1/2" SLOT WIDTH, 48" LENGTH, 8"INLET, SDA PLENUM. TYPICAL.3.RETURN AIR GRILLE. CLEAR ANODIZED FINISH.4.HD LINEAR BAR GRILLE IN FLOOR LIKE PRICE LBPH OR EQUAL. CLEAR ANODIZED.5.ALL DUCTWORK INSTALLED IN THIS AREA MUST BE OPERATIONAL AND BALANCED PRIOR TO INSTALLATION OF CEILING SYSTEM. CLOSELY COORDINATE INSTALLATION OF DUCTWORK WITH ALL TRADES.6.REFER TO ARCHITECTURAL ELEVATIONS FOR GRILLE ELEVATION.7.PROVIDE 24"x24"x12" DEEP INSULATED PLENUM ON BACK OF LOUVER. CONNECT 10/10 E.A. DUCTS FROM EXHAUST FANS BELOW TO PLENUM. BLANK OFF UNUSED LOUVER WITH 2" RIGID INSULATION AND SHEET-METAL. SEAL WATER-TIGHT. REFER TO A-SERIES DWGS FOR LOUVER LOCATION.8.PROVIDE 24"x24"x12" DEEP INSULATED PLENUM ON BACK OF LOUVER. CONNECT BLANK OFF UNUSED LOUVER WITH 2" RIGID INSULATION AND SHEET-METAL. SEAL WATER-TIGHT. REFER TO A-SERIES DWGS FOR LOUVER LOCATION.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD 8/28/2015 6:58:58 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt M201ALIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA A - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner NO R T H SC A L E : 1 / 8 " = 1 ' - 0 " FI R S T F L O O R - A R E A A - M E C H A N I C A L MA C H I N E B1 3 2 UN A S S I G N E D B1 2 9 FE L L O W B1 2 5 FE L L O W B1 2 7 FE L L O W B1 2 3 FE L L O W B1 0 8 FE L L O W B1 0 6 FE L L O W B1 0 2 FE L L O W B1 0 4 CH A I R M A N B1 0 0 AS S I S T A N T B1 3 1 WO M E N B1 1 0 ME N B1 1 1 ME C H A N I C A L B1 3 4 OF F I C E B1 3 0 FE L L O W B1 0 3 FE L L O W B1 0 1 FE L L O W B1 0 5 FE L L O W B1 0 7 FE L L O W B1 2 2 FE L L O W B1 2 6 UN A S S I G N E D B1 2 8 OF F I C E B1 2 0 EN C L A V E B1 1 9 WE L L N E S S RO O M B1 1 3 ST O R A G E / FU T U R E A S T . B1 1 7 ST O R A G E B1 1 6 EL E C T B1 1 5 WO R K A R E A B1 1 4 FE L L O W S AS S I S T A N T B1 2 1 A FE L L O W S AS S I S T A N T B1 1 8 A FE L L O W S AS S I S T A N T B1 1 8 B FE L L O W S AS S I S T A N T B1 0 9 A FE L L O W S AS S I S T A N T B1 1 2 B FE L L O W S AS S I S T A N T B1 1 2 A CO R R I D O R B1 1 2 17 5 17 0 16 0 16 0 16 0 16 0 21 0 21 0 21 0 24 0 15 0 15 0 17 5 27 5 20 0 21 0 22 0 21 0 21 0 21 0 21 0 24 0 20 0 15 0 15 0 15 0 15 0 20 0 20 0 20 0 12 " / 1 2 " E R 35 0 12 " / 1 2 " E R 35 0 12 5 1 M3 0 1 2 M3 0 1 16"/12" 20"/10" 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 2 4 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G M3 0 1 B3 1 2 24 " / 2 4 " 24"/8" 8" 24"/8" 32 5 18"/8" 20 0 20 0 CO R R I D O R B1 0 9 CO R R I D O R B1 2 1 24"/8" 24"/8" 16"/8" 14"/10" 24"/10" 8" 8" 8" 8" 10" 10" 10" 10" 10" 10"10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 16"/12" 10" 10" 8" 8" 20"/12" 20"/10" 8" 8" 16"/10" 16"/10" 10" 24 " / 1 2 " R G 24 " / 2 4 " R G 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " WS H P - N - B 1 0 1 WS H P - O - B 1 0 5 WS H P - M - B 1 2 2 WS H P - N - B 1 2 6 WS H P - O - B 1 2 9 WS H P - P - B 1 1 6 BB BB BB BB BB BB BB AA BB AA AA AA BB BB BB BB AA AA AA AA AA AA WS H P - L - B 1 1 9 75 75 WS H P - R - B 1 1 4 BA BB BC BD B6 B3 B4 B5 B7 B4 . 3 B4 . 8 B1 B2 B1 . 6 B2 . 4 B5 . 7 BA.6 BC.4 18"/8" 8" 8" 24"/8" 20"/10" 1 14 ' - 0 " EF - B 1 3 2 8"8" WS H P - K - B 1 0 0 4 3 6 4 2 5 2 4 3 J M40 1 J M40 1 J M4 0 1 J M4 0 1 12 " / 1 2 " T G 8"/ 8 " BB BB BB BB 8" 8" PLAN NOTES:#PLAN NOTES:1.FIRE DAMPER WITH ACCESS AT DUCTWORK PENETRATION.2.BALANCE BRANCH VENTILATION AIR DUCT TO 80 CFM.3.BALANCE BRANCH VENTILATION AIR DUCT TO 120 CFM.4.BALANCE BRANCH VENTILATION AIR DUCT TO 160 CFM.5.BALANCE BRANCH VENTILATION AIR DUCT TO 240 CFM.6.BALANCE BRANCH VENTILATION AIR DUCT TO 380 CFM.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.G2. ALL SUPPLY DUCTWORK FROM WSHP'S SHALL BE INTERNALLY LINED WITH 1"ACOUSTICAL DUCT LINER UP TO BRANCH DUCTWORK TAKE-OFFS.G3.PROVIDE LINED ACOUSTICAL DUCT ELBOW WITH FILTER PROVISION ON EACHAND EVERY HORIZONTAL HEAT PUMP.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD 8/28/2015 5:14:57 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt M201BLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA B - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204317.634.4672LIBERTY FUND HEADQUARTERSOwner NO R T H SC A L E : 1 / 8 " = 1 ' - 0 " FI R S T F L O O R - A R E A B - M E C H A N I C A L DN UN I S E X RE S T R O O M C1 0 9 EN C L A V E C1 0 7 LI B R A R I A N C1 0 4 LI B R A R Y S U P P O R T C1 0 3 LI B R A R Y C1 0 0 AR C H I V E C1 0 6 20 0 90 27 5 1 M3 0 2 55 0 16 " / 4 8 " 16 " / 4 8 " 26 " / 6 " 1 6 " / 6 " 8" / 6 " 1 4 " / 1 0 " 1 4 " / 1 0 " 30 0 30 0 S. A . A N D R . A . D U C T U P T O 2 N D F L O O R . 24 " / 1 2 " R G 24 " / 1 2 " R G EB B R - A EB B R - A 1 4 4 6 EB B R - A EB B R - A 1 EB B R - A 1 EB B R - A 1 5 5 5 1 2 " 1 0 " 48 " / 6 " R G 64 0 48 " / 4 " S G 44 0 48 " / 4 " S G 20 0 18 " x 1 8 " R G 60 0 24 " / 1 2 " R G 20 0 42 " / 4 " S G 19 0 42 " / 4 " S G 19 0 42 " / 4 " S G 19 0 42 " / 4 " S G 19 0 42 " / 4 " S G 19 0 42 " / 4 " S G 19 0 42 " / 4 " S G 19 0 42 " / 4 " S G 19 0 FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A FT R - A AS S I S T A N T C1 1 0 OF F I C E C1 1 1 EL E V A T O R L O B B Y C1 0 5 OF F I C E C1 0 8 ST A I R C1 0 2 ST A I R C1 0 1 ST O R A G E C1 1 2 10"/10" WS H P - N - C 1 1 1 6 " WS H P - J - C 1 1 0 2 2 2 6 24 " / 1 2 " R G 24 " / 1 2 " R G 14 " / 4 " 14 " / 4 " EF - C 1 0 9 7 8 6" / 6 " 6"/6" 9 9 10 " TY P . 10 " TY P . 10 10 10 10 5 5 CA CE C7 . 9 C5 . 1 C5 . 9 C3 . 1 B1 CDCB C6 A3 C5 C4 C3 C7 C8 A5 CJCH CF CG C1 C2 C9 CC D5 A2 A4 C2 . 5 C8 . 5 CG . 9 D4 . 3 D4 . 7 C7 . 5 C3 . 5 10 " / 1 0 " 10 ' - 0 " 6' - 6 " 13 ' - 0 " 7' - 0 " J M4 0 1 J M4 0 1 CA CD CB CC 16 " / 4 8 " 14 " / 1 8 " 16 " / 4 8 " 40 " / 2 0 " 12 " / 3 6 " 40 " / 1 4 " 14 " / 1 4 " WS H P - G - C 0 0 1 30 " / 1 6 " 12 " / 1 0 " 12 " / 3 6 " 8" 10 " 4" / 4 2 " 10 " 4" / 4 2 " 6" / 4 8 " 6" / 4 8 " 4" / 4 8 " 4" / 4 8 " 4" / 4 8 " 4" / 4 8 " WS H P - H - C 1 0 0 A PLAN NOTES:#PLAN NOTES:1.EBBR-A - DRAFT BARRIER AT BASE OF WINDOW. PEDESTAL MOUNTED. LIKE TPI-9300 DBT SERIES. 100 W/FT. CLEAR ANODIZED FINISH. 12 GA ENCLOSURE. INTEGRAL THERMOSTAT. 3-1/2" MAX DEPTH X 6" TALL. FINISHED BACK AND ENDCAPS. FIELD VERIFY EXACT ENCLOSURE LENGTHS REQUIRED.2.HD LINEAR BAR GRILLE IN FLOOR LIKE PRICE LBPH-25C SERIES. CLEAR ANODIZED FINISH.3.DOUBLE DEFLECTION SUPPLY AIR GRILLE WITH OPPOSED BLADE DAMPER.4.1" INTERNALLY LINED DUCT UP AND DOWN IN CHASE. COORDINATE STRUCTURAL OPENINGS IN FLOOR WITH S-SERIES DWGS.5.HYDRONIC FINNED TUBE RADIATION. REFER TO A-SERIES DWG'S FOR ENCLOSURE DETAIL.6.DUCTWORK TO BE INTERNALLY LINED WITH 1" ACOUSTICAL DUCT LINER.7.6" ROUND FROM EF UP TO ROOF AND TERMINATE WITH GOOSENECK.8.10/10 VENTILATION AIR DUCT UP AND DOWN IN CHASE. 10/10 S.A. DUCT AND 12/10 R.A. DUCT UP TO SECOND LEVEL. PROVIDE FIRE DAMPER WITH ACCESS PANEL AT ALL DUCT PENETRATIONS.9.BALANCE VENTILATION AIR DUCT SERVING WSHP TO 50 CFM.10.CONTINUOUS LINEAR SLOT DIFFUSER LIKE PRICE "AS" SERIES. 1-1" SLOT, WITH 2 ACTIVE LENGTH SECTIONS. PROVIDE INSULATED PLENUM WITH 10" INLET. PROVIDE BLANKOFFS FOR INACTIVE SECTIONS.11.ALL DUCTWORK INSTALLED IN THIS AREA MUST BE BALANCED AND OPERATIONAL PRIOR TO INSTALLATION OF CEILING SYSTEM.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD 8/28/2015 5:16:04 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt M201CLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA C - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner NO R T H SC A L E : 1 / 8 " = 1 ' - 0 " FI R S T F L O O R - A R E A C - M E C H A N I C A L SC A L E : 1 / 8 " = 1 ' - 0 " Li b r a r y S e c t i o n 1 DW ICE ME N S D1 1 7 CO R R I D O R D1 0 7 CO R R I D O R D1 0 2 WO M E N D1 1 3 BR E A K O U T D1 0 9 VE S T I B U L E D1 0 0 ST A F F B R E A K A R E A D1 0 1 DI N I N G D1 0 8 KI T C H E N D1 0 3 ST O R A G E D1 0 5 GO O D R I C H R O O M D1 1 0 EX E R C I S E D1 1 5 ME C H A N I C A L D1 0 4 LO C K E R S D1 1 6 JA N I T O R I A L D1 1 2 LO C K E R D1 1 4 CO R R I D O R D1 0 6 ST O R A G E D1 0 3 A ST O R A G E D1 0 3 B 50 0 50 0 20 0 22 5 27 5 27 5 8" / 8 " E R 10 0 8" / 8 " E R 10 0 12 " / 1 2 " E R 25 0 8" / 8 " E R 75 12 " / 1 2 " E R 25 0 2 4 "/1 6 " 2 2 "/1 6 " 2 2 "/1 6 "2 6 "/1 4 " 2 4 " / 1 4 " 2 6 " / 1 4 " 2 2 " / 1 6 " 2 6 " / 1 4 " 2 4 " / 1 4 " 2 0 " / 1 4 " 3 0 " / 1 4 " 2 8 " / 1 4 " 2 6 " / 1 4 " 3 0 "/1 4 " 2 0 " / 1 2 " 1 6 "/1 8 "36 " / 1 6 " R G 14 0 0 8 " 24 " / 2 4 " R G 24 " / 2 4 " R G 1 2 " 96 " / 2 4 " L O U V E R 72 " / 2 4 " L O U V E R M3 0 3 PL A N V I E W 8 " 30 " / 8 " S G 27 5 1 6 "/8 " 48 " / 6 " R G 48 " / 6 " R G 48 " / 6 " R G 48 " / 6 " R G 48 " / 6 " R G 48 " / 6 " R G 48 " / 6 " R G 48 " / 6 " R G 24 " / 2 4 " ID F R O O M D1 0 4 A EF - A 1 2 " 19 0 19 0 19 0 19 0 19 0 19 0 19 0 19 0 1 2 2 3 3 2 EW H - A 2 3K W EW H - D 3 3K W EW H - D 1 3K W 8 " 10 " 13 9 0 C F M 10 0 0 C F M 14 0 0 C F M 24 " / 8 " S G 20 0 24 " / 8 " S G 20 0 24 " / 8 " S G 20 0 24 " / 8 " S G 20 0 24 " / 8 " S G 20 0 24 " / 8 " S G 20 0 1 8 " 8" 8" 1 0 " 1 2 " 22 5 12 " / 1 2 " T G 8" 1 2 " 48 " / 6 " R G 48 " / 6 " R G 4 4 2 8 "/1 0 " 2 8 "/1 4 " 48 " / 6 " R G 2 4 " / 1 0 " 7 7 7 5 19 0 19 0 19 0 7 23 0 23 0 23 0 23 0 23 0 23 0 6 EF - D 1 1 6 WS H P - J - D 1 1 3 WS H P - J - D 1 0 5 CE DA DF DB DB . 8 DE D4 A1 AA C1 D5 DC D1 D2 DD AC D3 . 5 D3 AG . 8 D4 . 3 D4 . 7 DA . 9 19 0 19 0 19 0 19 0 19 0 2 0 " / 1 0 " 1 6 " / 1 0 " 1 0 " / 1 0 " 2 0 " / 1 0 " 1 6 " / 1 0 " 1 0 " / 1 0 " 8 14 0 14 0 14 0 14 0 14 0 14 0 14 0 14 0 14 0 14 0 1 6 "/1 0 " 1 6 "/1 0 " 1 6 "/1 0 " 1 6 "/1 0 " 9 9 9 9 2 4 " / 1 4 " 2 4 "/1 4 " 2 6 " / 1 4 " 1 2 " / 1 2 " 48 " / 6 " R G 5 10 " 10 " 8" 1 4 " / 1 2 " 1 4 " / 1 4 " 1 4 "/1 4 " 2 2 "/1 6 " 1 2 " / 1 2 " 1 0 " / 1 0 " 8" 8" 8" 8"8" 2 8 " / 1 0 " WS H P - J - D 1 1 7 J M4 0 1 J M4 0 1 4 4 10 10 PLAN NOTES:#PLAN NOTES:1.PROVIDE 36"x24"x24" DEEP INSULATED PLENUM ON BACK OF LOUVER.CONNECT EXHAUST AIR DUCTS TO LOUVER. BLANK OFF UNUSED LOUVER WITH 2" RIGID INSULATION AND SHEET METAL. SEAL WATER-TIGHT.2. OFFSET E.A. DUCT DOWN AND INSTALL FAN MAXIMUM 12" ABOVE LAYIN CEILING.3.ROUTE DUCTWORK IN TRUSS OPENINGS.4.LINEAR SLOT DIFFUSER LIKE PRICE SDS50, 1 SLOT, 1/2" SLOT WIDTH, 48"LENGTH, 8" INLET, SDA PLENUM. TYPICAL.5.LINEAR SLOT DIFFUSER LIKE PRICE SDS50, 1 SLOT, 1/2" SLOT WIDTH, 48"LENGTH, 8" INLET, SDA PLENUM. TYPICAL.6.LINEAR SLOT DIFFUSER LIKE PRICE SDS50, 1 SLOT, 1/2" SLOT WIDTH, 48"LENGTH, 8" INLET, SDA PLENUM. TYPICAL.7.LINEAR BAR GRILLE IN BULKHEAD LIKE PRICE LBP-15B. CLEAR ANODIZED ALUMINUM. TYPICAL.8.OFFSET DUCTWORK AS REQUIRED IN THIS AREA TO AVOID STRUCTURE.9.BALANCED DUCTWORK INSTALLED IN THIS AREA MUST BE OPERATIONAL AND BALANCED PRIOR TO INSTALLATION OF CEILING SYSTEM.10.LINEAR SLOT RETURN DIFFUSER LIKE PRICE SDR50, 1 SLOT, 1/2" SLOT WIDTH,48" LENGTH. TYPICAL.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD 8/28/2015 6:59:25 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt M201DLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA D - MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner NO R T H SC A L E : 1 / 8 " = 1 ' - 0 " FI R S T F L O O R - A R E A D - M E C H A N I C A L OP E N O F F I C E B2 1 9 EL E C T R I C A L B2 2 0 ST O R A G E B2 2 1 ST O R A G E B2 1 2 CO N F E R E N C E B2 0 3 PU B L I S H I N G B2 0 5 PU B L I S H I N G B2 0 7 VP P U B L I S H I N G B2 0 9 PU B L I S H I N G B2 0 8 PU B L I S H I N G B2 0 6 PU B L I S H I N G B2 0 4 VP - A C C O U N T I N G B2 2 6 AC C O U N T I N G B2 2 7 HR O F F I C E B2 2 9 UN A S S I G N E D B2 3 0 UN A S S I G N E D B2 3 1 ST O R A G E B2 1 7 IT O F F I C E B2 3 5 GO V E R N O R ' S R O O M B2 0 2 WO M E N B2 1 6 ME N B2 1 5 UN A S S I G N E D B2 2 3 PU B L I S H I N G B2 1 0 AC C O U N T I N G B2 2 4 32 0 32 0 47 5 21 0 22 0 21 0 22 5 22 5 42 0 20 0 20 0 20 0 20 0 12 5 25 0 25 0 12 5 15 0 15 0 20 0 20 0 24 0 20 0 40 0 24 0 23 0 29 0 29 0 29 0 29 0 29 0 20 0 15 0 32 5 20 0 12 " / 1 2 " E R 35 0 12 " / 1 2 " E R 35 0 20 0 20 0 1 M3 0 1 2 M3 0 1 18"/18" 18"/18" 16"/12" 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G 24 " / 1 2 " R G M3 0 1 B2 1 8 CO R R I D O R B2 1 4 ST A I R B2 0 0 CO R R I D O R B2 1 1 OP E N O F F I C E B2 2 2 CO R R I D O R B2 0 1 CO R R I D O R B2 3 6 WO R K R O O M B2 1 3 B2 0 1 A B2 3 6 A 16"/10" 10" 10"/10" IT O F F I C E B2 3 4 UN A S S I G N E D B2 3 3 UN A S S I G N E D B2 3 2 16"/10" 10" 10" 10" 22"/10" 12"/10" 22"/10" 10" 10" 20"/10" 10" 10" 10" 22"/10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 12"/10" 18"/12" 24"/12" 12" /10" 8" 8" 10"/10" 12"/8" 8" 8" 29 0 WS H P - O - B 2 0 2 WS H P - L - B 2 0 3 WS H P - N - B 2 0 5 WS H P - O - B 2 0 9 WS H P - N - B 2 2 3 WS H P - O - B 2 2 6 WS H P - O - B 2 3 0 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " 24 " / 2 4 " WS H P - L - B 2 3 5 WS H P - P - B 2 1 2 WS H P - U - B 2 1 5 BB BB BB BB BB BB BB BB BB CC AA AA DD BB BB BB BB BB DD BB BB 16"/10" BA BB BC BD B6 B3 B4 B5 B7 B4 . 3 B4 . 8 B1 B2 B1 . 6 B2 . 4 B5 . 7 BA.6 BC.4 1 2 16"/12" 16"/12" 10" 5 5 9 10 8" 4 8" 8 6 8"/8" 8"/6" 4 3 24 " / 1 2 " R G 8" EF - B 2 2 0 24 " / 1 2 " R G 7 7 23 0 8" 8" 8" 8" 10" ME C H A N I C A L B2 1 8 5 J M4 0 1 J M4 0 1 J M4 0 1 J M4 0 1 J M4 0 1 PLAN NOTES:#PLAN NOTES:1.18/18 O.A. INTAKE DUCTWORK UP AND CONNECT TO INSULATED PLENUM ON BACK OF 60/12 LOUVER. INSTALL LOUVER HIGH AS POSSIBLE.2.18/18 EXHAUST AIR DUCTWORK UP AND CONNECT TO INSULATED PLENUM ON BACK OF 60/12 LOUVER. INSTALL LOUVER HIGH AS POSSIBLE.3.BALANCE BRANCH VENTILATION AIR DUCT TO 40 CFM.4.BALANCE BRANCH VENTILATION AIR DUCT TO 80 CFM.5.BALANCE BRANCH VENTILATION AIR DUCT TO 120 CFM.6.ROUTE 6" VENTILATION AIR DUCT FROM WSHP-OA SUPPLY IN MECHANICAL ROOM TO RETURN AIR INLET. BALANCE TO 80 CFM.7.PROVIDE FIRE DAMPER IN DUCTWORK AT WALL PENETRATION.8.BALANCE BRANCH VENTILATION AIR DUCT TO 160 CFM.9.BALANCE BRANCH VENTILATION AIR DUCT TO 230 CFM.10.BALANCE BRANCH VENTILATION AIR DUCT TO 580 CFM.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD 8/28/2015 5:20:09 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt M202BLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 SECOND FLOOR -AREA B -MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner NO R T H SC A L E : 1 / 8 " = 1 ' - 0 " SE C O N D F L O O R - A R E A B - M E C H A N I C A L UP P E R L I B R A R Y C2 0 0 A/ V S P A C E C2 0 6 1 M2 0 1 C 72 " / 3 0 " R G 38 0 0 72 " / 3 0 " R G 38 0 0 2 2 3 8 48 " / 4 " 28 5 48 " / 4 " 28 5 AR C H I V E C2 0 4 ST O R A G E C2 0 3 ME C H A N I C A L C2 0 5 8" 24 " / 1 2 " R G 17 5 17 5 18 " / 1 8 " 10 " / 1 0 " 12 " / 1 0 " 24 " / 1 2 " R G 27 0 12 4 " / 4 " 28 5 12 4 " / 4 " 28 5 48 " / 4 " 28 5 48 " / 4 " 28 5 12 4 " / 4 " 28 5 12 4 " / 4 " 28 5 1 1 1 1 1 5 1 1 5 5 1 5 1 1 1 WS H P - K - C 2 0 4 16 " / 1 0 " 10"/10" WS H P - L - C 2 0 6 EC S - A CA CE C7 . 9 C5 . 1 C5 . 9 C3 . 1 B1 CDCB C6 A3 C5 C4 C3 C7 C8 DA A5 A1 CJCH CF CG C1 C2 C9CC D5 A2 C2 . 5 C8 . 5 AG . 8 CG . 9 D4 . 3 D4 . 7 C7 . 5 C3 . 5 22 " / 1 2 " 10 0 12" 12 " / 1 2 " 6 14 " / 1 8 " 6 7 9 10 48 " / 4 " TY P . 48 " / 4 " TY P . WS H P - L - C 1 0 4 J M4 0 1 J M4 0 1 8" PLAN NOTES:#PLAN NOTES:1.DOUBLE DEFLECTION SUPPLY AIR GRILLE WITH OPPOSED BLADE DAMPER. CUSTOM COLOR AND FINISH AS SELECTED BY ARCH. BLANK OFF UNUSED PORTIONS OF GRILLES.2.RETURN AIR GRILLE LIKE TITUS 350ZRL OR EQUAL. PROVIDE FIRE DAMPER ON BACK OF GRILLE. ELEVATION OF GRILLE TO BE CLOSELY COORDINATED WITH WALL CONSTRUCTION. REFER TO ARCHITECTURAL ELEVATIONS FOR GRILLE LOCATION.CONNECT RETURN AIR DUCT FROM BELOW TO PLENUM.3.TRANSITION DUCTWORK AT FLOOR.4.MAINTAIN FULL ACCESS TO ROOF HATCH IN THIS AREA.5.SUPPLY GRILLE NOT USED.6.DUCTWORK TO BE INTERNALLY LINED WITH 1" ACOUSTICAL DUCT LINER.7.MAINTAIN CLEARANCES TO ROOF ACCESS IN THIS AREA. SEE A-SERIES DWGS.8.S.A. AND R.A.DUCTWORK DOWN TO FIRST FLOOR IN CHASE. PROVIDE FIRE DAMPER WITH ACCESS AT CHASE PENETRATIONS. SEE M201C FOR CONTINUATION.9.10/10 VENTILATION AIR DUCT DOWN TO FIRST FLOOR.10.BALANCE MANUAL VOLUME DAMPER IN BRANCH DUCT TO 50 CFM FOR EACH WSHP.CONNECT VENTILATION AIR DUCT TO WSHP RETURN AIR DUCTWORK.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD 8/28/2015 5:20:49 PM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt M202CLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 SECOND FLOOR -AREA C -MECHANICAL1404308/28/15 MJE MJEMEP Engineers DA#14043 R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672LIBERTY FUND HEADQUARTERSOwner NO R T H SC A L E : 1 / 8 " = 1 ' - 0 " SE C O N D F L O O R - A R E A C - M E C H A N I C A L T T TT T T PLAN NOTES:#PLAN NOTES: 1.3" GS & GR PIPING UP TO FIRST FLOOR. 2.1-1/2" GS & GR, AND 1" CONDENSATE PIPING UP TO FIRST FLOOR. 3.ALL GS & GR PIPING INSTALLED IN LOWER LIBRARY C001 SHALL BE DOUBLE CONTAINMENT PIPE. 4.ROUTE CONDENSATE TO MOP SINK. 5.3/4" HS & HR PIPING UP TO FINNED TUBE RADIATION ON LEVEL ABOVE. SEE M211C FOR CONTINUATION. GENERAL NOTES: G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES. IT WORK ROOM C010STORAGE C011 ELEV EQUIP C002 CORRIDOR C004 IT STORAGE C007 MDF C008 STAIR C005 STORAGE C003 STAIR C014 1 2 3" 1-1/2" 3" 1-1/2" M312 1 3 3 ELECTRICAL ROOM C001A 1" 1" 1" 5 5 55 1" 3" 1" 1-1/4" 1" 1" 1" WSHP-L-C001A WSHP-N-A107 WSHP-N-A109 WSHP-N-C108 WSHP-L-C004 BA CA CE C7.9 C5.1 C5.9 C3.1 B1 CD CB C6A3C5C4C3 C7 C8 DA DB A5 A1 AA AE CJ CH CF CG C2 C9 CC D5 B1.6 A4 BA.6 C2.5 C8.5 AG.8 CG.9 D4.7 C7.5C3.5 HS HR D D D D D EF-C002 J M411 WSHP-L-C004 WSHP-E-C011 WSHP-E-C010 1-1/2" D D 4 EF-C008 D CO D PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue: 07/20/15 BID PACKAGE #1 KEYPLAN A B C D 8/ 2 8 / 2 0 1 5 4 : 1 1 : 1 0 P M C: \ U s e r s \ s f i t e s \ D o c u m e n t s \ 1 4 0 4 3 - L I B E R T Y F U N D H Q M E P _ s f i t e s . r v t M210C LI B E R T Y F U N D H E A D Q U A R T E R S CA R M E L , I N D I A N A 08/28/2015 BID PACKAGE #2 LOWER LEVEL - AREA C - MECHANICAL PIPING 14043 08/28/15 MJE MJE MEP Engineers DA#14043 R.E. Dimond and Associates, Inc. 732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672 LIBERTY FUND HEADQUARTERS Owner NORTH SCALE: 1/8" = 1'-0" LOWER LEVEL - MECHANICAL PIPING DN T T T T T T T H VESTIBULE A100 MEN A112 WOMEN A113 CLOSET A103 OFFICE A104 STORAGE A102 PICK-UP/STORAGE A114 3" 3" 4" CONFERENCE A109 CONFERENCE A107 WSHP-N-A107 WSHP-N-A109 WSHP-O-A104 WSHP-U-A101 WSHP-N-A114 SEE M211D FOR CONTINUATION. SEE M211B FOR CONTINUATION. CORRIDOR A108 WSHP-U-A106 WSHP-U-A104 1-1/4" 1-1/4" 3" 1" 3" 3" 1-1/4" BA BB BC CE C7.9 C5.1 C5.9 C3.1 BD B1 A3 DA DF DB DB.8 DE A1.1 A4.9 A1.9 A4.1 AD AH A5 A1 AA AE AB AF D5 B1.6 A2 A4 AC AG BA.6 BC.4 AC.6 AG.6 AE.5 DA.10 DA.11 DA.14 WSHP-U-A106 WSHP-O-A104 WSHP-N-A114 WSHP-U-A101 1 J M411 J M411 D 2 D PLAN NOTES:#PLAN NOTES: 1.ROUTE PIPING ABOVE CEILING. SPACE IS LIMITED. COORDINATE LOCATION WITH ALL TRADES. 2.LOCATE ISOLATION VALVES ABOVE ACCESSIBLE CEILING. GENERAL NOTES: G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES. PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue: 07/20/15 BID PACKAGE #1 KEYPLAN A B C D 8/ 2 8 / 2 0 1 5 4 : 1 4 : 0 9 P M C: \ U s e r s \ s f i t e s \ D o c u m e n t s \ 1 4 0 4 3 - L I B E R T Y F U N D H Q M E P _ s f i t e s . r v t M211A LI B E R T Y F U N D H E A D Q U A R T E R S CA R M E L , I N D I A N A 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA A - MECHANICAL PIPING 14043 08/28/15 MJE MJE MEP Engineers DA#14043 R.E. Dimond and Associates, Inc. 732 North Capitol Avenue Indianapolis, Indiana 46204 317.634.4672 LIBERTY FUND HEADQUARTERS Owner NORTH SCALE: 1/8" = 1'-0" FIRST FLOOR - MECHANICAL PIPING T T T T T T T T T T T T MA C H I N E B1 3 2 UN A S S I G N E D B1 2 9 FE L L O W B1 2 5 FE L L O W B1 2 7 FE L L O W B1 2 3 FE L L O W B1 0 8 FE L L O W B1 0 6 FE L L O W B1 0 2 FE L L O W B1 0 4 CH A I R M A N B1 0 0 AS S I S T A N T B1 3 1 WO M E N B1 1 0 ME N B1 1 1 ME C H A N I C A L B1 3 4 OF F I C E B1 3 0 FE L L O W B1 0 3 FE L L O W B1 0 1 FE L L O W B1 0 5 FE L L O W B1 0 7 FE L L O W B1 2 2 FE L L O W B1 2 6 UN A S S I G N E D B1 2 8 OF F I C E B1 2 0 EN C L A V E B1 1 9 WE L L N E S S RO O M B1 1 3 ST O R A G E / FU T U R E A S T . B1 1 7 ST O R A G E B1 1 6 EL E C T B1 1 5 WO R K A R E A B1 1 4 FE L L O W S AS S I S T A N T B1 2 1 A FE L L O W S AS S I S T A N T B1 1 8 A FE L L O W S AS S I S T A N T B1 1 8 B FE L L O W S AS S I S T A N T B1 0 9 A FE L L O W S AS S I S T A N T B1 1 2 B FE L L O W S AS S I S T A N T B1 1 2 A CO R R I D O R B1 1 2 3" 1-1 / 2 " 3" M3 1 1 1 WS H P - K - B 1 0 0 WS H P - N - B 1 0 1 WS H P - O - B 1 0 5 WS H P - X - B 1 1 7 WS H P - P - B 1 1 6 WS H P - L - B 1 1 9 WS H P - R - B 1 1 4 WS H P - M - B 1 2 2 WS H P - N - B 1 2 6 WS H P - O - B 1 2 9 2" 1" 1- 1 / 4 " 2" 1" 1-1 / 4 " 1- 1 / 4 " 1- 1 / 4 " 1" WS H P - N - B 1 0 1 WS H P - O - B 1 0 5 WS H P - M - B 1 2 2 WS H P - N - B 1 2 6 WS H P - O - B 1 2 9 WS H P - R - B 1 1 4 WS H P - P - B 1 1 6 WS H P - L - B 1 1 9 1" 1- 1 / 2 " SE E M 2 1 1 A F O R CO N T I N U A T I O N 1- 1 / 2 " 1" BA BB BC BD B6 B3 B4 B5 B7 B4 . 3 B4 . 8 B1 B2AH B1 . 6 B2 . 4 B5 . 7 BA.6 BC.4 EF - B 1 3 2 EF - B 1 1 5 2" J M4 1 1 CO D D D D D WS H P - K - B 1 0 0 D D 1- 1 / 4 " 1-1 / 2 " 1" 1"1" 1" 1" PLAN NOTES:#PLAN NOTES:1.PLAN NOTE #1.GENERAL NOTES:G1.REFER TO SHEET MP001 FOR ADDITIONAL GENERAL NOTES.PROJECT NUMBER DATE DRAWN BY CHECKED BY Date:Issue:08/28/15BID PACKAGE #2 KEYPLANABCD 8/31/2015 8:59:17 AM\\RED-SBS02\RedirectedFolders\meast\My Documents\14043-LIBERTY FUND HQ MEP_meast.rvt M211BLIBERTY FUND HEADQUARTERS CARMEL, INDIANA 08/28/2015 BID PACKAGE #2 FIRST FLOOR - AREA B - MECHANICAL PIPING1404308/28/15 MJE MJEMEP Engineers DA#14043R.E. Dimond and Associates, Inc.732 North Capitol Avenue Indianapolis, Indiana 46204317.634.4672LIBERTY FUND HEADQUARTERSOwner NO R T H SC A L E : 1 / 8 " = 1 ' - 0 " FI R S T F L O O R - A R E A B - M E C H A N I C A L P I P I N G