HomeMy WebLinkAbout2015077- CLA -Carmel, IN-K1-K4 31.THESE DRAWINGS ARE TO BE USED AS AN INSTRUMENT OF
REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL
TRADES SHALL VERIFY THE INFORMATION AS INDICATED ON THESE
PLANS.
2.DIMENSIONS AND REQUIREMENTS FOR ALL EQUIPMENT THAT IS
LISTED AS EXISTING, PROVIDED BY OTHERS OR PROVIDED BY
OWNER, MUST BE VERIFIED WITH THE APPROPRIATE PARTIES.
3.ALL LOCAL, STATE AND NATIONAL CODES SHALL APPLY.
4.THESE UTILITY REQUIREMENT DRAWINGS INDICATE THE UTILITY AND
LOCATION OF REQUIREMENTS BASED ON THE EQUIPMENT SPECIFIED.
5.ALL EQUIPMENT SHALL BE PLUMBED IN STRICT CONFORMANCE WITH
THE MANUFACTURER'S INSTRUCTIONS AND/OR SHOP DRAWINGS.
6.UNLESS OTHERWISE NOTED, ALL DIMENSIONS SHOWN ON THIS PLAN
ARE FROM THE FINISHED FLOOR, CEILING, WALLS OR COLUMN
CENTERLINES TO THE CENTERLINE OF THE ROUGH-INS.
7.ALL PLUMBING CONNECTIONS SHALL BE EXTENDED AND
INTERCONNECTED TO CONNECTION POINTS ON THE EQUIPMENT BY
OTHERS. UNLESS SPECIFIED, ALL HARDWARE REQUIRED FOR THESE
CONNECTIONS SHALL BE SUPPLIED BY THE PLUMBING CONTRACTOR.
8.SURFACE MOUNTED PIPING WILL NOT BE ALLOWED. ALL PIPING
SHALL BE EXTENDED THROUGH AND OUT OF BUILDING WALLS WHERE
POSSIBLE. WHERE SURFACE MOUNTED PLUMBING IS UNAVOIDABLE,
IT MUST BE COORDINATED WITH HOCKENBERGS.
9.528*+,162872))/2256+28/'%(678%%('83´$%29(
FINISHED FLOOR AND BROUGHT TO THE REQUIRED HEIGHT AFTER
EQUIPMENT IS SET IN PLACE.
10.ONLY COMPONENTS SUPPLIED STANDARD BY THE MANUFACTURER
ARE INCLUDED. ALL HARDWARE REQUIRED FOR CONNECTIONS
SHALL BE SUPPLIED BY THE PLUMBING CONTRACTOR. SUCH
COMPONENTS INCLUDE BUT ARE NOT LIMITED TO, SHUT-OFFS,
PRESSURE REGULATORS, VACUUM BREAKERS, P-TRAPS, BACKFLOW
PREVENTERS, ETC.
11.PLUMBING CONTRACTOR TO VERIFY THAT ALL APPLIANCES ARE
SUPPLIED WITH APPROPRIATE GAS PRESSURE AND THAT ANY
VARIANCES IN GAS PRESSURE BE CLEARLY IDENTIFIED AND
BROUGHT TO THE IMMEDIATE ATTENTION OF HOCKENBERGS.
12.ALL INDIRECT WASTE AND CONDENSATE DRAIN LINES SHALL BE
EXTENDED FROM EQUIPMENT FITTINGS TO APPROPRIATE DRAINS AS
CODES REQUIRE, BY OTHERS.
13.UNLESS OTHERWISE SPECIFIED, HOT WATER SUPPLIED TO BOOSTER
+($7(56+$//%($0,1,0807(03(5$785(2))
14.PLUMBING CONTRACTOR TO VERIFY WATER TEMPERATURE
REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. ANY
DISCREPANCY BETWEEN MANUFACTURER'S REQUIREMENTS AND
TEMPERATURES PROVIDED SHALL BE CLEARLY IDENTIFIED AND
BROUGHT TO THE IMMEDIATE ATTENTION OF HOCKENBERGS.
15.PLUMBING CONTRACTOR TO PROVIDE INSULATED HOT WATER
CONNECTIONS BETWEEN BOOSTER HEATER AND DISHMACHINE.
16.UNLESS OTHERWISE SPECIFIED BY CODE, ALL DRAIN LINES FOR
DISPOSERS SHALL BY-PASS GREASE INTERCEPTORS.
PLUMBING NOTES
PLUMBING SYMBOLS
FLOOR DRAIN
DIRECT DRAIN
INDIRECT DRAIN
FUNNEL FLOOR DRAIN
FILTERED COLD WATER
GAS
HUB DRAIN
HOT WATER CONNECTION
COLD WATER CONNECTION
FLOOR SINK-HALF COVER
FLOOR SINK
+27:$7(5&211(&7,210,1,080
F
HD
G
PLUMBING ROUGH-IN NOTE
(SEE SCHEDULE)
ITEM NUMBER
CONNECTION NUMBER?
?
LOCATE "P" TRAP
(IF REQUIRED)
OUTSIDE OF
WALK-IN BOX
1" AIR GAP
1/2" SLOPE PER FOOT (MIN.),
RUN TIGHT TO WALL & SECURE
TO WALL
HEATER TAPE WRAPPED AROUND
DRAIN (WALK-IN FREEZER ONLY)
(FREEZERS ONLY) ELEC. HEAT
TAPE SPIRALED AND TAPED ON
FREEZER DRAIN LINE BEFORE
APPLYING INSULATION BY OTHERS
FLOOR SINK OR FLOOR DRAIN
W/FUNNEL (PER LOCAL CODE)
COOLER/FREEZER
COIL
NOT TO SCALE
WALK-IN DRAIN LINE DETAIL
ELECT. OUTLET FOR
DRAIN LINE HEAT
TAPE (FREEZERS
ONLY), MOUNTED
INSIDE OF WALK-IN
(BY E.C.). SEE SHEET
K2 FOR LOCATION
16
B
16
A
1'
-
2
"
8"
8'
-
8
"
1'
-
2
"
28
A
1'
-
0
"
8'-6"
11"
11"
4"
2'-0"2'-7"8"
1'
-
3
"
2'-10"PLUMBING SCHEDULE
1
A
HAND SINK
1/2" CW, 14" AFF (TWO LOCTIONS)
16
B
DISPOSER
2" DIRECT WASTE, 8" AFF
16
A
DISPOSER
1/2" CW, 24" AFF
1
B
HAND SINK
1/2" HW, 14" AFF (TWO LOCTIONS)
1
C
HAND SINK
1-1/2" DIRECT WASTE, 16" AFF (TWO LOCTIONS)
2.2
B
FAUCET
1/2" HW, 14" AFF
2
A
PREP TABLE W/ SINKS
FLOOR SINK, PC TO EXTEND INDIRECT WASTE TO FLOOR SINK
2.2
A
FAUCET
1/2" CW, 14" AFF
12
A
POT & PAN SINK
FLOOR SINK, PC TO EXTEND INDIRECT WASTE TO FLOOR SINK
12.1
A
PRE-RINSE W/ ADD-A-FAUCET
1/2" CW, 14" AFF
12.1
B
PRE-RINSE W/ ADD-A-FAUCET
1/2" HW, 14" AFF
14
B
DISH MACHINE
FLOOR SINK, PC TO EXTEND INDIRECT WASTE TO FLOOR SINK
14
A
DISHMACHINE
+:$))
16.1
A
PRE-RINSE UNIT
1/2" CW, 14" AFF
16.1
B
PRE-RINSE UNIT
1/2" HW, 14" AFF
28
A
MOP SINK
2" DIRECT WASTE, STUB-UP
28.1
A
SERVICE FAUCET
1/2" CW, 36" AFF
28.1
B
SERVICE FAUCET
1/2" HW, 36" AFF
PLUMBING SCHEDULE
53
A
DISHMACHINE
1/2" CW, STUB-UP 4" AFF
53
B
DISHMACHINE
FLOOR SINK, EXTEND INDIRECT WASTE LINES
FROM DISHMACHINE TO FLOOR SINK
2'
-
9
"
PL
U
M
B
I
N
G
R
E
Q
U
I
R
E
M
E
N
T
S
P
L
A
N
K-3
RE
V
I
S
I
O
N
S
Drawn By:
Scale:
Release Date:
Project Number:
CO
P
Y
R
I
G
H
T
2
0
1
5
B
Y
H
O
C
K
E
N
B
E
R
G
S
E
Q
U
I
P
M
E
N
T
&
S
U
P
P
L
Y
C
O
.
,
I
N
C
.
A
L
L
R
I
G
H
T
S
R
E
S
E
R
V
E
D
.
US
E
O
F
T
H
I
S
D
R
A
W
I
N
G
F
O
R
A
N
Y
P
U
R
P
O
S
E
I
S
S
U
B
J
E
C
T
T
O
W
R
I
T
T
E
N
A
G
R
E
E
M
E
N
T
W
I
T
H
HO
C
K
E
N
B
E
R
G
S
.
P
R
I
M
A
R
I
L
Y
,
T
H
I
S
D
R
A
W
I
N
G
S
H
O
W
S
T
H
E
G
E
N
E
R
A
L
A
R
R
A
N
G
E
M
E
N
T
O
F
FI
X
T
U
R
E
S
A
N
D
E
Q
U
I
P
M
E
N
T
F
O
R
T
H
E
C
O
N
V
E
N
I
E
N
C
E
O
F
T
H
E
C
O
N
T
R
A
C
T
O
R
S
A
N
D
I
S
M
A
D
E
FR
O
M
A
V
A
I
L
A
B
L
E
I
N
F
O
R
M
A
T
I
O
N
.
A
L
L
D
I
M
E
N
S
I
O
N
S
S
H
O
W
N
O
N
T
H
E
S
E
D
R
A
W
I
N
G
S
A
R
E
CO
N
C
E
R
N
E
D
O
N
L
Y
W
I
T
H
T
H
E
F
I
X
T
U
R
E
A
R
R
A
N
G
E
M
E
N
T
S
A
N
D
A
R
E
S
U
B
J
E
C
T
T
O
V
E
R
I
F
I
C
A
T
I
O
N
OF
S
I
T
E
C
O
N
D
I
T
I
O
N
S
,
L
O
C
A
L
C
O
D
E
S
,
A
N
D
W
O
R
K
P
R
O
V
I
D
E
D
B
Y
O
T
H
E
R
S
.
W
H
I
L
E
HO
C
K
E
N
B
E
R
G
S
H
A
S
M
A
D
E
E
V
E
R
Y
E
F
F
O
R
T
T
O
P
R
O
V
I
D
E
A
C
C
U
R
A
T
E
I
N
F
O
R
M
A
T
I
O
N
,
I
T
S
H
A
L
L
NO
T
B
E
R
E
S
P
O
N
S
I
B
L
E
F
O
R
A
N
Y
E
R
R
O
R
S
O
R
O
M
I
S
S
I
O
N
S
I
N
T
H
I
S
D
R
A
W
I
N
G
.
1/4" = 1'-0"
5.4.2015
SILVER
2015077
CH
I
L
D
R
E
N
'
S
L
E
A
R
N
I
N
G
A
D
V
E
N
T
U
R
E
CA
R
M
E
L
,
I
N
J:
\
D
r
a
w
i
n
g
L
i
b
r
a
r
y
\
2
0
1
5
\
2
0
1
5
0
7
7
-
C
L
A
-
C
a
r
m
e
l
,
I
N
\
2
0
1
5
0
7
7
-
C
L
A
-
C
a
r
m
e
l
,
I
N
.
d
w
g
,
6
/
4
/
2
0
1
5
2
:
5
2
:
0
7
P
M
,
s
a
m
s