HomeMy WebLinkAbout2015077- CLA -Carmel, IN-K1-K4 31.THESE DRAWINGS ARE TO BE USED AS AN INSTRUMENT OF REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES SHALL VERIFY THE INFORMATION AS INDICATED ON THESE PLANS. 2.DIMENSIONS AND REQUIREMENTS FOR ALL EQUIPMENT THAT IS LISTED AS EXISTING, PROVIDED BY OTHERS OR PROVIDED BY OWNER, MUST BE VERIFIED WITH THE APPROPRIATE PARTIES. 3.ALL LOCAL, STATE AND NATIONAL CODES SHALL APPLY. 4.THESE UTILITY REQUIREMENT DRAWINGS INDICATE THE UTILITY AND LOCATION OF REQUIREMENTS BASED ON THE EQUIPMENT SPECIFIED. 5.ALL EQUIPMENT SHALL BE PLUMBED IN STRICT CONFORMANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND/OR SHOP DRAWINGS. 6.UNLESS OTHERWISE NOTED, ALL DIMENSIONS SHOWN ON THIS PLAN ARE FROM THE FINISHED FLOOR, CEILING, WALLS OR COLUMN CENTERLINES TO THE CENTERLINE OF THE ROUGH-INS. 7.ALL PLUMBING CONNECTIONS SHALL BE EXTENDED AND INTERCONNECTED TO CONNECTION POINTS ON THE EQUIPMENT BY OTHERS. UNLESS SPECIFIED, ALL HARDWARE REQUIRED FOR THESE CONNECTIONS SHALL BE SUPPLIED BY THE PLUMBING CONTRACTOR. 8.SURFACE MOUNTED PIPING WILL NOT BE ALLOWED. ALL PIPING SHALL BE EXTENDED THROUGH AND OUT OF BUILDING WALLS WHERE POSSIBLE. WHERE SURFACE MOUNTED PLUMBING IS UNAVOIDABLE, IT MUST BE COORDINATED WITH HOCKENBERGS. 9.528*+,162872))/2256+28/'%(678%%('83´$%29( FINISHED FLOOR AND BROUGHT TO THE REQUIRED HEIGHT AFTER EQUIPMENT IS SET IN PLACE. 10.ONLY COMPONENTS SUPPLIED STANDARD BY THE MANUFACTURER ARE INCLUDED. ALL HARDWARE REQUIRED FOR CONNECTIONS SHALL BE SUPPLIED BY THE PLUMBING CONTRACTOR. SUCH COMPONENTS INCLUDE BUT ARE NOT LIMITED TO, SHUT-OFFS, PRESSURE REGULATORS, VACUUM BREAKERS, P-TRAPS, BACKFLOW PREVENTERS, ETC. 11.PLUMBING CONTRACTOR TO VERIFY THAT ALL APPLIANCES ARE SUPPLIED WITH APPROPRIATE GAS PRESSURE AND THAT ANY VARIANCES IN GAS PRESSURE BE CLEARLY IDENTIFIED AND BROUGHT TO THE IMMEDIATE ATTENTION OF HOCKENBERGS. 12.ALL INDIRECT WASTE AND CONDENSATE DRAIN LINES SHALL BE EXTENDED FROM EQUIPMENT FITTINGS TO APPROPRIATE DRAINS AS CODES REQUIRE, BY OTHERS. 13.UNLESS OTHERWISE SPECIFIED, HOT WATER SUPPLIED TO BOOSTER +($7(56+$//%($0,1,0807(03(5$785(2)ƒ) 14.PLUMBING CONTRACTOR TO VERIFY WATER TEMPERATURE REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. ANY DISCREPANCY BETWEEN MANUFACTURER'S REQUIREMENTS AND TEMPERATURES PROVIDED SHALL BE CLEARLY IDENTIFIED AND BROUGHT TO THE IMMEDIATE ATTENTION OF HOCKENBERGS. 15.PLUMBING CONTRACTOR TO PROVIDE INSULATED HOT WATER CONNECTIONS BETWEEN BOOSTER HEATER AND DISHMACHINE. 16.UNLESS OTHERWISE SPECIFIED BY CODE, ALL DRAIN LINES FOR DISPOSERS SHALL BY-PASS GREASE INTERCEPTORS. PLUMBING NOTES PLUMBING SYMBOLS FLOOR DRAIN DIRECT DRAIN INDIRECT DRAIN FUNNEL FLOOR DRAIN FILTERED COLD WATER GAS HUB DRAIN HOT WATER CONNECTION COLD WATER CONNECTION FLOOR SINK-HALF COVER FLOOR SINK +27:$7(5&211(&7,21ƒ0,1,080 F HD G PLUMBING ROUGH-IN NOTE (SEE SCHEDULE) ITEM NUMBER CONNECTION NUMBER? ? LOCATE "P" TRAP (IF REQUIRED) OUTSIDE OF WALK-IN BOX 1" AIR GAP 1/2" SLOPE PER FOOT (MIN.), RUN TIGHT TO WALL & SECURE TO WALL HEATER TAPE WRAPPED AROUND DRAIN (WALK-IN FREEZER ONLY) (FREEZERS ONLY) ELEC. HEAT TAPE SPIRALED AND TAPED ON FREEZER DRAIN LINE BEFORE APPLYING INSULATION BY OTHERS FLOOR SINK OR FLOOR DRAIN W/FUNNEL (PER LOCAL CODE) COOLER/FREEZER COIL NOT TO SCALE WALK-IN DRAIN LINE DETAIL ELECT. OUTLET FOR DRAIN LINE HEAT TAPE (FREEZERS ONLY), MOUNTED INSIDE OF WALK-IN (BY E.C.). SEE SHEET K2 FOR LOCATION 16 B 16 A 1' - 2 " 8" 8' - 8 " 1' - 2 " 28 A 1' - 0 " 8'-6" 11" 11" 4" 2'-0"2'-7"8" 1' - 3 " 2'-10"PLUMBING SCHEDULE 1 A HAND SINK 1/2" CW, 14" AFF (TWO LOCTIONS) 16 B DISPOSER 2" DIRECT WASTE, 8" AFF 16 A DISPOSER 1/2" CW, 24" AFF 1 B HAND SINK 1/2" HW, 14" AFF (TWO LOCTIONS) 1 C HAND SINK 1-1/2" DIRECT WASTE, 16" AFF (TWO LOCTIONS) 2.2 B FAUCET 1/2" HW, 14" AFF 2 A PREP TABLE W/ SINKS FLOOR SINK, PC TO EXTEND INDIRECT WASTE TO FLOOR SINK 2.2 A FAUCET 1/2" CW, 14" AFF 12 A POT & PAN SINK FLOOR SINK, PC TO EXTEND INDIRECT WASTE TO FLOOR SINK 12.1 A PRE-RINSE W/ ADD-A-FAUCET 1/2" CW, 14" AFF 12.1 B PRE-RINSE W/ ADD-A-FAUCET 1/2" HW, 14" AFF 14 B DISH MACHINE FLOOR SINK, PC TO EXTEND INDIRECT WASTE TO FLOOR SINK 14 A DISHMACHINE +:ƒ$)) 16.1 A PRE-RINSE UNIT 1/2" CW, 14" AFF 16.1 B PRE-RINSE UNIT 1/2" HW, 14" AFF 28 A MOP SINK 2" DIRECT WASTE, STUB-UP 28.1 A SERVICE FAUCET 1/2" CW, 36" AFF 28.1 B SERVICE FAUCET 1/2" HW, 36" AFF PLUMBING SCHEDULE 53 A DISHMACHINE 1/2" CW, STUB-UP 4" AFF 53 B DISHMACHINE FLOOR SINK, EXTEND INDIRECT WASTE LINES FROM DISHMACHINE TO FLOOR SINK 2' - 9 " PL U M B I N G R E Q U I R E M E N T S P L A N K-3 RE V I S I O N S Drawn By: Scale: Release Date: Project Number: CO P Y R I G H T 2 0 1 5 B Y H O C K E N B E R G S E Q U I P M E N T & S U P P L Y C O . , I N C . A L L R I G H T S R E S E R V E D . US E O F T H I S D R A W I N G F O R A N Y P U R P O S E I S S U B J E C T T O W R I T T E N A G R E E M E N T W I T H HO C K E N B E R G S . P R I M A R I L Y , T H I S D R A W I N G S H O W S T H E G E N E R A L A R R A N G E M E N T O F FI X T U R E S A N D E Q U I P M E N T F O R T H E C O N V E N I E N C E O F T H E C O N T R A C T O R S A N D I S M A D E FR O M A V A I L A B L E I N F O R M A T I O N . A L L D I M E N S I O N S S H O W N O N T H E S E D R A W I N G S A R E CO N C E R N E D O N L Y W I T H T H E F I X T U R E A R R A N G E M E N T S A N D A R E S U B J E C T T O V E R I F I C A T I O N OF S I T E C O N D I T I O N S , L O C A L C O D E S , A N D W O R K P R O V I D E D B Y O T H E R S . W H I L E HO C K E N B E R G S H A S M A D E E V E R Y E F F O R T T O P R O V I D E A C C U R A T E I N F O R M A T I O N , I T S H A L L NO T B E R E S P O N S I B L E F O R A N Y E R R O R S O R O M I S S I O N S I N T H I S D R A W I N G . 1/4" = 1'-0" 5.4.2015 SILVER 2015077 CH I L D R E N ' S L E A R N I N G A D V E N T U R E CA R M E L , I N J: \ D r a w i n g L i b r a r y \ 2 0 1 5 \ 2 0 1 5 0 7 7 - C L A - C a r m e l , I N \ 2 0 1 5 0 7 7 - C L A - C a r m e l , I N . d w g , 6 / 4 / 2 0 1 5 2 : 5 2 : 0 7 P M , s a m s