Loading...
HomeMy WebLinkAboutC20 ESCINITIAL DATE DPOR PM DES DRW Engineering Associates, Inc. CEI PROJECT NO. NO. DATE REVISIONS 10/10/14 10/17/14 DESCRIPTION BZA SUBMITTAL ADLS/ DP SUBMITTAL 2/26/15 SUBMITTAL REVISED PER COMMENTS 4/30/15 SUBMITTAL REVISED PER COMMENTS 6/4/15 PERMIT / BID SET JOB # PROJ#28436.0 DRAWING: 28436-CS.dwg LAST SAVED BY: RNEDKOV LOCATION: C:\CEI-CAD\Vault\28436.0 CLA - 116th St & Coll ege Ave - Carmel, IN\Drawings\Design\28436-CS.dwg OVERLAP 5' MIN. SILT FENCE MATERIAL TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH THREE TIES SPACED AT 30" ON CENTER (SEE NOTE 1) 5' MIN. 3' MIN. 15" MIN. MAX. 18" 2" X 4" WOOD FRAME DROP INLET WITH GRATE AND CROSS BRACING ATTACH THE WOVEN WIRE FENCE TO EACH POST WITH THREE WIRE TIES OR OTHER FASTENERS (SEE NOTE 1) 1" x 2" STAKE 1. ATTACH THE WOVEN WIRE FENCE TO EACH POST AND THE GEOTEXTILE TO THE WOVEN WIRE FENCE (SPACED EVERY 30") WITH THREE WIRE TIES OR OTHER FASTENERS, ALL SPACED WITHIN THE TOP 8" OF THE FABRIC. ATTACH EACH TIE DIAGONALLY 45 DEGREES THROUGH THE FABRIC, WITH EACH PUNCTURE AT LEAST 1" VERTICALLY APART. 2. WHEN TWO SECTIONS OF SILT FENCE MATERIAL ADJOIN EACH OTHER, THEY SHALL BE OVERLAPPED ACROSS TWO POSTS. 3. MAINTENANCE SHALL BE PERFORMED AS NOTED IN THE SWPPP. DEPTH OF ACCUMULATED SEDIMENTS MAY NOT EXCEED ONE-HALF THE HEIGHT OF THE FABRIC. MAINTENANCE CLEANOUT MUST BE CONDUCTED REGULARLY TO PREVENT ACCUMULATED SEDIMENTS FROM REACHING ONE-HALF THE HEIGHT OF THE SIFT FENCE MATERIAL BEING ABOVE GRADE. 4. ALL SILT FENCE INLETS SHALL INCLUDE WIRE SUPPORT. POSTS: 2 x 4 WOODEN STAKE FENCE: WOVEN WIRE, 14-1/2 Ga., 6" MAX. MESH OPENING FABRIC: IN ACCORDANCE WITH ASTM D 6461, LATEST EDITION SILT FENCE INLET PRTECTION N.T.S. MATERIAL A MIN. EXTEND SILT FENCE WOVEN WIRE FENCE WITH SILT FENCE EXTEND WIRE FENCE MIN. OF 3" IN GROUND SECURELY FASTEN OVERLAPPING ENDS OF SILT FENCE MATERIAL TO ADJACENT STAKES WITH THREE WIRE TIES OR OTHER FASTENERS MATERIAL COVER 1'-0" INTO GROUND 10' MAX. C-C WOVEN WIRE FENCE (MIN. 14-1/2 GAUGE, 60" MIN. FENCE POSTS, FILTER FABRIC FLOW GROUND LINE ELEVATION FLOW WOVEN WIRE FENCE (MIN. 14 1/2 GAUGE, FLOW 18" 6" GROUND LINE 4" X 4" TRENCH 3'-0" 6" 4" 1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES OR STAPLES. 2. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED 4. MAINTENANCE SHALL BE PERFORMED AS NOTED IN THE EROSION CONTROL PLAN. COLLECTED MATERIAL POSTS: STEEL EITHER T OR U TYPE OR 2"x2" HARDWOOD FENCE: WOVEN WIRE, 14-1/2 GA. 6" MAX. MESH OPENING FILTER FABRIC: CROSS-SECTION (MIN.) COMPACTED BACKFILL COMPACTED MAX. 6" MESH SPACING) WITH FILTER CLOTH COVER 24" AT TOP AND MID SECTION. BY 6" AND FOLDED. SHALL BE REMOVED WHEN "BULGES" DEVELOP IN THE SILT FENCE. 1. MIRAFI 140NS 2. PHILLIPS 66 SUPAC 4NP 3. DUPONT TYPAR 3341 OVER WIRE FENCE DRIVEN MIN. 18" INTO GROUND. MAX. 6" MESH SPACING) 4. OR APPROVED EQUAL 10' MAX. C-C TEMPORARY SILT FENCE N.T.S. BACKFILL MIN. 8" INTO GROUND EMBEDDED FILTER FABRIC MIN. OF 2" INTO TRENCH EXTEND WIRE FENCE A 1. MINIMUM DIMENSIONS: 50'x20'x1.5' (LENGTH, WIDTH AND SUMP DEPTH. THE MINIMUM LENGTH INCLUDES INGRESS AND EGRESS FROM THE SUMP. 2. THE AGGREGATE SIZE FOR CONSTRUCTION OF THE PAD SHALL BE 4-6 INCH STONE. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH OUT. 3. THE THICKNESS OF THE PAD SHALL NOT BE LESS THAN 8 INCHES. USE GEOTEXTILE FABRIC UNDER THE GRAVEL TO IMPROVE STABILITY OF THE FOUNDATION. 4. ALTERNATIVELY, INSTALL 3" ASPHALT LIFT OVER A STABLE ROADWAY BASE WITH THE SAME DIMENSIONS IDENTIFIED ABOVE. 5. THE RUN-OUT PAD SHALL EXTEND 50' PAST EGRESS RAMP AND DRAIN BACK INTO SUMP, OR TO A SUITABLE COLLECTION AND TREATMENT FACILITY. 6. INSTALL FENCING, AS NECESSARY, TO MANAGE VEHICLE TRAFFIC. 7. INSPECT ROUTINELY TO ASSESS THE WATER LEVELS WITHIN THE SUMP, THE DEPTH OF ACCUMULATED SEDIMENT AND IDENTIFY AND AREAS THAT REQUIRE MAINTENANCE. 8. REMOVE ACCUMULATED SEDIMENT FROM THE TIRE WASH FACILITY TO MAINTAIN TIRE WASH SUMP DEPTH. SEDIMENT MAY BE PUMPED, PIPED OR VACUUMED TO A SUITABLE COLLECTION AND TREATMENT FACILITY. 9. CLEAN OR REPLACE ROCK WHEN CLOGGED WITH SEDIMENT AND RE-GRADE AS NEEDED. 10. MAINTAIN THE RUN-OUT PAD AS NECESSARY TO PREVENT SEDIMENT ACCUMULATION. 11. IMMEDIATELY REMOVE AND ROCK THAT IS CARRIED FROM THE PAD TO THE ROADWAY. 12. ENSURE THAT WASH WATER DRAINAGE, COLLECTION AND TREATMENT SYSTEM IS FUNCTIONING. STABILIZED RUN-OUT AREA GRADE TO DRAIN TO WASH 1.00 4:1 MAX. 4:1 MAX. 10' 50' 10' 16' 14' 12" CONTRACTOR TO PROVIDE WATER SUPPLY TO MAINTAIN 12" OF WATER AT ALL TIMES DIRECTION OF TRAVEL TO EXIT SITE B B' A A' 18" FILTER FABRIC (OMIT WITH GUNITE OPTION) CRUSHED BASE COURSE (4" TO 6" ROCK, 8" THICK) OR CONTRACTOR APPLIED GUNITE NOTES: PLAN SECTION A-A' SECTION B-B' N.T.S. N.T.S. N.T.S. 8" (OMIT WITH GUNITE OPTION) FOLD FILTER FABRIC 4"x12" 4-6" STONE 4-6" STONE TEMPORARY CONSTRUCTION EXIT DRIVE THROUGH TIRE WASH N.T.S. 3' 3' 45"x24" PAINTED WHITE PLYWOOD BLACK LETTERS 6" HEIGHT WOOD POSTS 4"x4"x8' (ABOVE GRADE) STAKE (TYP.) 10' MIN.* 10' MIN.* TEMPORARY CONCRETE WASHOUT N.T.S. 2 LAYERS 6 MIL PLASTIC LINING PLAN SECTION A-A WOOD FRAME SECURELY FASTENED AROUND ENTIRE PERIMETER WITH TWO OPPOSING STAKES A A N.T.S. TWO STACKED 2"x12" ROUGH WOOD FRAME 1. *DENOTES THE INTERIOR DIMENSION. 2. CONCRETE WASHOUT SHALL BE AT LEAST 50 FT. FROM ANY STORM SEWER INLET. 3. THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30 FT. OF THE TEMPORARY CONCRETE WASHOUT FACILITY. N.T.S. CONCRETE WASHOUT CONCRETE WASHOUT SIGN DETAIL (OR EQUIVALENT) 2. GEOTEXTILE SHALL BE A WOVEN POLYPROPYLENE FABRIC THAT MEETS OR EXCEEDS REQUIREMENTS IN THE SPECIFICATIONS TABLE. GEOTEXTILE BAG OVERFLOW HOLES (OPTIONAL) LOOPS SIZED FOR 1" REBAR. USE REBAR FOR A HANDLE TO EMPTY FILTER SACK AT A SEDIMENT COLLECTION LOCATION. LOOPS SIZED FOR 1" REBAR. LIFT FILTER BAG FROM INLET USING REBAR FOR HANDLES. 2"X2"X3/4" RUBBER BLOCK (TYP) PROFILE VIEW OF INSTALLED FILTER SACK 1. REMOVE TRAPPED SEDIMENT WHEN BRIGHTLY COLORED EXPANSION RESTRAINT CAN NO LONGER BE SEEN. 3. PLACE AN OIL ADSORBENT PAD OR PILLOW OVER INLET GRATE WHEN OIL SPILLS ARE A CONCERN. 4. INSPECT PER REGULATORY REQUIREMENTS. GRAB TENSILE STRENGTH GRAB TENSILE ELONGATION PUNCTURE MULLEN BURST TRAPEZOID TEAR UV RESISTANCE APPARENT OPENING SIZE FLOW RATE PERMITTIVITY PROPERTIES TEST METHOD UNITS ASTM D-4632 ASTM D-4632 ASTM D-4833 ASTM D-3786 ASTM D-4533 ASTM D-4355 ASTM D-4751 ASTM D-4491 ASTM D-4491 300 LBS 20 % 120 LBS 800 PSI 120 LBS 80 % 40 US SIEVE 40 GAL/MIN/SQ FT 0.55 SEC -1 GRAB TENSILE STRENGTH GRAB TENSILE ELONGATION PUNCTURE MULLEN BURST TRAPEZOID TEAR UV RESISTANCE APPARENT OPENING SIZE FLOW RATE PERMITTIVITY PROPERTIES TEST METHOD UNITS ASTM D-4632 ASTM D-4632 ASTM D-4833 ASTM D-3786 ASTM D-4533 ASTM D-4355 ASTM D-4751 ASTM D-4491 ASTM D-4491 LOW TO MODERATE FLOW GEOTEXTILE FABRIC SPECIFICATION TABLE MODERATE TO HIGH FLOW GEOTEXTILE FABRIC SPECIFICATION TABLE 265 LBS 20 % 135 LBS 420 PSI 45 LBS 90 % 20 US SIEVE 200 GAL/MIN/SQ FT 1.5 SEC -1 FILTER SACKS (GRATED INLETS) N.T.S. INLET GRATE 1/4" BRIGHTLY COLORED NYLON ROPE EXPANSION RESTRAINT 5. THE WIDTH, "W", OF THE FILTER SACK SHALL MATCH THE INSIDE WIDTH OF THE GRATED INLET BOX. 6. THE DEPTH, "D", OF THE FILTER SACK SHALL BE BETWEEN 18 INCHES AND 36 INCHES. 7. THE LENGTH, "L", OF THE FILTER SACK SHALL MATCH THE INSIDE LENGTH OF THE GRATED INLET BOX. DO NOT USE IN PAVED AREAS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS. SECURE LIFTING LOOPS TO OR UNDER SURROUNDING SURFACE. 1/4" BRIGHTLY COLORED NYLON ROPE EXPANSION RESTRAINT DEPTH = D FINISH GRADE 20' MINIMUM 150' 6" MINIMUM HARD SURFACE PUBLIC ROAD 2"-3" STONE GEOTEXTILE UNDERLINER TEMPORARY STONE CONSTRUCTION ENTRANCE N.T.S. 6/2/15